Description: RYAN / 900SF REMODEL - RELOCATE KITCHEN + (2) NEW DOORS
Type: BUILDING RESIDENTIAL Subtype: REMODEL Status: ISSUED
(WEB)
Applied: 4/4/2022 EPRS
Approved: 1/3/2023 JFU
Issued: 2/3/2023 ONLINE
Finaled:
Expired: 2/3/2024 ECON
Parcel No: 762230031 Site Address: 80170 HERMITAGE LA QUINTA,CA 92253
Subdivision: 28118 Block: Lot: 4
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Valuation: $100,000.00 Occupancy Type: Construction Type:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: 900SF REMODEL [ENGINEERED]. RELOCATE KITCHEN, NEW WINE DISPLAY AND WET BAR + (2) NEW SLIDING DOORS. THIS PERMIT
DOES NOT INCLUDE LIGHTING ALTERATIONS. 2019 CALIFORNIA BUILDING CODES.
Process Summary
274 "<oliif 31
1
Applied to Approved
Approved to Issued
ADDITIONAL SITES AM
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
E-MAIL
AARON HICKSON
4/4/2022
4/4/2022
Regarding the above permit submittal. Please upload Energy
calculations and structural calculations for review. Attach to
the above permit number do not apply for a new permit.
E-MAIL
JAKE FUSON
6/3/2022
6/3/2022
NOTIFIED APPLICANT OF 1ST REVIEW COMMENTS, SENT
CORRECTION LIST VIA EMAIL.
E-MAIL
JAKE FUSON
12/1/2022
12/1/2022
NOTIFIED APPLICANT OF 2ND REVIEW COMMENTS, SENT
CORRECTION LIST VIA EMAIL.
E-MAIL
JAKE FUSON
1/3/2023
1/3/2023
NOTIFIED APPLICANT THAT PLANS ARE APPROVED AND
PERMIT IS READY TO ISSUE.
Printed: Thursday, September 14, 2023 10:56:17 AM
1 of 7
CRWSYSTE S
Permit Details PERMIT NUMBS
City of La Quinta BRES2022-028
NOTE
JAKE FUSON
1/23/2023
1/23/2023
CHANGE OF CONTRACTOR PROCESSED --SEE ATTACHED
LETTER OF RELEASE.
PLAN CHECK/PERMIT
EXTENSION
AJ ORTEGA
2/1/2023
2/1/2023
APPLICATION FOR PERMIT EXTENSION GRANTED FOR THE
MAXIMUM AMOUNT OF DAYS UNDER THE 2019 CODE,
PERMIT MUST BE OBTAINED BY JUNE 29, 2023.
RESUBMITTAL
JAKE FUSON
9/13/2022
9/13/2022
h.
A.
IL
CONDITIONS
-
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
Mike Yakovich
160 N Luring Dr Ste. C
Palm Springs
CA
92262
(760)864-7364
removedfromeprsacces
s@staff.com
CONTRACTOR
VINCERE INDUSTRIES INC
30670 HILL DRIVE
THOUSAND
PALMS
CA
92276
(760)864-7364
projects@vincereindus
tries.com
CONTRACTOR
(HISTORY)
MY GENERAL CONSTRUCTION INC
160 N LURING SUITE C
PALM SPRINGS
CA
92262
(760)864-7364
contact.mygc@gmail.c
om
OWNER
Michelle Ryan
80170 Hermitage
La Quinta
CA
92253
(760)864-7364
office.mygc@gmail.co
m
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
CHANGE OF
CONTR/ARCH/OWNER
PROCESSING
101-0000-42600
0
$117.30
$117.30
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Total Paid for ADMINISTRATIVE: $117.30 $117.30
HOURLY CHARGE CITY
BUILDING STAFF
101-0000-42600
0.25
$43.75
$43.75
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
HOURLY CHARGE
ESGIL CIVIL ENGINEER
101-0000-42600
1
$105.00
$105.00
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Printed: Thursday, September 14, 2023 10:56:17 AM
2 of 7
CRWSYSTE S
Permit Details PERMIT NUMBS
City of La Quinta BRES2022-0283
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
HOURLY CHARGE
ESGIL CIVIL ENGINEER
101-0000-42600
1
$105.00
$105.00
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Total Paid for BLDG CITY STAFF - PER HOUR: $253.75 $253.75
BSAS 01473 FEE
101-0000-20306
0
$4.00
$4.00
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Total Paid for BUILDING STANDARDS ADMINISTRATION $4.00 $4.00
BSA:
DEVICES, FIRST 20
101-0000-42403
0
$27.79
$27.79
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
DEVICES, FIRST 20 PC
101-0000-42600
0
$27.79
$27.79
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Total Paid for ELECTRICAL 2021: $55.58 $55.58
FIXTURE/TRAP
101-0000-42401
0
$41.67
$41.67
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
FIXTURE/TRAP PC
101-0000-42600
0
$41.67
$41.67
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
WATER SYSTEM
INST/ALT/REP
101-0000-42401
0
$27.78
$27.78
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
WATER SYSTEM
INST/ALT/REP PC
101-0000-42600
0
$27.78
$27.78
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Total Paid for PLUMBING 2021: $138.90 $138.90
RECORDS
MANAGEMENT FEE -
MAJOR
101-0000-42416
0
$21.00
$21.00
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00
REMODEL, EA
ADDITIONAL 5005F
101-0000-42400
0
$50.02
$50.02
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
REMODEL, EA
ADDITIONAL 500SF PC
101-0000-42600
0
$40.02
$40.02
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
REMODEL, FIRST 100SF
101-0000-42400
0
$56.69
$56.69
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Printed: Thursday, September 14, 2023 10:56:17 AM
3 of 7
CRWSYSTEMS
Permit Details PERMIT NUMBS
City of La Quinta BRES2022-0283
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
REMODEL, FIRST 100SF
PC
101-0000-42600
0
$155.06
$155.06
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Total Paid for REMODEL 2021: $301.79 $301.79
SMI - RESIDENTIAL
101-0000-20308
0
$13.00
$13.00
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $13.00 $13.00
TECHNOLOGY
ENHANCEMENT FEE
502-0000-43611
0
$5.00
$5.00
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
ALTERATIONS/ADDITIO
NS - RESIDENTIAL
101-0000-42400
0
$81.00
$81.00
2/3/23
WEB14244
808453288
CREDIT
968718
ECON
Total Paid for ZONING CLEARANCE - PLANNING PLAN $81.00 $81.00
CHECK:
' ' A 991.32 $991.32
INSPECTION
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
COMPLETED
DATE
RESULT
REMARKS
NOTES
FOOTINGS
MHU
6/16/2023
6/19/2023
DISAPPROVE
D
3" MINIMUM CLEARANCE REBAR TO EARTH
RFI FROM ENGINEER FOR FOOTING OR HAVE
WORK MATCH DETAILS THIS INSPECTION IS
FOR THE 2 PAD FOOTINGS AT REAR SGD FOR
LR
UNDERGROUND PLBG
MHU
7/31/2023
7/31/2023
DISAPPROVE
D
EXPOSE ALL NEW PIPE AND FITTINGS DWV
SYSTEM TO BE UNDER TEST CONDITIONS AT
INSPECTION
UNDERGROUND ELEC
MHU
7/31/2023
7/31/2023
DISAPPPROVE
CONDUIT BURIAL DEPTH IS INSUFFICIENT
PARENT PROJECTS
REVIEWS
Printed: Thursday, September 14, 2023 10:56:17 AM
4 of 7
CRWSYSTE S
1111111111 A
City of La Quints11111111.
BRES2022-028
Permit Details PERMIT NUMBER
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
DATE
STATUS
REMARKS
1ST BLDG NS (2 WK)
ESGIL
4/4/2022
4/18/2022
4/25/2022
APPROVED
1ST PERMIT TECH —
ETRAKIT (1 DAY)
AARON
HICKSON
4/4/2022
4/5/2022
4/7/2022
COMPLETE
STRUCTURAL CALCULATIONS UPLOADED
1ST BLDG NS —
ETRAKIT (2 WK)
JAKE FUSON
4/4/2022
4/18/2022
6/3/2022
REVISIONS REQUIRED
SEE ATTACHED 1ST REVIEW CORRECTION LIST.
1ST FIRE ETRAKIT
(1 WK)
KOHL
HETRICK
4/4/2022
4/11/2022
4/25/2022
NOT REQUIRED
EXISTING /
NONSPRINKLERED
1ST PLANNING —
ETRAKIT (1 WK)
SIJIFREDO
FERNANDEZ
4/4/2022
4/11/2022
4/11/2022
READY FOR APPROVAL
2ND BLDG NS —
ETRAKIT (1 WK)
JAKE FUSON
9/13/2022
9/20/2022
12/1/2022
REVISIONS REQUIRED
SEE 2ND REVIEW CORRECTION LIST (ATTACHED).
2ND BLDG STR —
ETRAKIT (1 WK)
ESGIL
12/1/2022
12/8/2022
12/8/2022
APPROVED
THE STRUCTURAL DRAWINGS THAT WERE
SUBMITTED WITH THE 2ND SUBMITTAL WERE
PREPARED BY A DIFFERENT ENGINEER AND
DIFFER FROM THE ORIGINAL PLANS THAT WERE
PREVIOUSLY APPROVED. PLEASE PROVIDE
COMPLETE STRUCTURAL REVIEW OF THESE NEW
PLANS.
3RD BLDG NS —
ETRAKIT (1 DAY)
JAKE FUSON
1/3/2023
1/4/2023
1/3/2023
APPROVED
illi
BOND INFORMATION
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
4/4/2022
Etrakit Public
Registration
1ST SUBMITTAL
STRUCTURAL SHEETS
S_Revised Ryan
Residence 02-04-22.pdf
1
DOC
4/4/2022
Etrakit Public
Registration
1ST SUBMITTAL PLANS
TD 20 209
MRRfinalcomplete.pdf
1
DOC
4/7/2022
Etrakit Public
Registration
1ST SUBMTTAL
STRUCTURAL SHEETS
S_Ryan Residence 07-24
-2021_1.pdf
1
Printed: Thursday, September 14, 2023 10:56:17 AM
5 of 7
CRWSYSTE S
Permit Details Ai
City of La Quinta
PERMIT NUMBER
BRES2022-0283
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
4/7/2022
Etrakit Public
Registration
1ST SUBMITTAL
STRUCTURAL
CALCULATIONS
S_Project Calcs Ryan
Residence 07-07-
2021_1.pdf
1
DOC
9/12/2022
Etrakit Public
Registration
2ND SUBMITTAL
STRUCTURAL
CALCULATIONS
220906 Calculations
Hermitage.pdf
1
DOC
9/12/2022
Etrakit Public
Registration
2ND SUBMITTAL
RESPONSES
BRES2022 0283 1ST
REVIEW CORRECTION
LIST Hermitage.pdf
1
DOC
9/12/2022
Etrakit Public
Registration
2ND SUBMITTAL PLANS
Set of Plans
Hermitage.pdf
1
DOC
1/3/2023
Etrakit Public
Registration
3RD SUBMITTAL -
RESPONSES
Hermitage 1
01032023.pdf
1
DOC
1/3/2023
Etrakit Public
Registration
3RD SUBMITTAL -
PLANS
Hermitage 3
01032023.pdf
1
DOC
1/3/2023
Etrakit Public
Registration
3RD SUBMITTAL -
ENERGY DOCUMENTS
Hermitage 4
01032023.pdf
1
DOC
1/3/2023
Etrakit Public
Registration
3RD SUBMITTAL -
STRUCTURAL
CALCULATIONS
Hermitage 5
01032023.pdf
1
DOC
4/25/2022
ESGIL
ESGIL STAMPED PLANS
S_Revised Ryan
Residence 02-04-22- IW
Approved.pdf
0
DOC
4/25/2022
JAKE FUSON
1ST REVIEW ESGIL
INVOICE
BRES2022-0283 - 1ST
REVIEW ESGIL
INVOICE.pdf
0
DOC
4/25/2022
JAKE FUSON
1ST REVIEW ESGIL
TRANSMITTAL
BRES2022-0283 - 1ST
REVIEW ESGIL
TRANSMITTAL.pdf
0
Printed: Thursday, September 14, 2023 10:56:17 AM
6 of 7
CRWSYSTE S
Permit Details Ai
City of La Quinta
PERMIT NUMBER
BRES2022-0283
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
6/3/2022
JAKE FUSON
1ST REVIEW
CORRECTION LIST
BRES2022-0283 - 1ST
REVIEW CORRECTION
LIST.pdf
1
DOC
12/1/2022
JAKE FUSON
2ND REVIEW
CORRECTION LIST
BRE52022-0283 - 2ND
REVIEW CORRECTION
LIST.pdf
1
DOC
12/8/2022
JAKE FUSON
2ND REVIEW ESGIL
INVOICE
BRES2022-0283 - 2ND
REVIEW - ESGIL
INVOICE.pdf
1
DOC
12/8/2022
JAKE FUSON
2ND REVIEW ESGIL
TRANSMITTAL
BRES2022-0283 - 2ND
REVIEW - ESGIL
TRANSMITTAL.pdf
1
DOC
1/3/2023
JAKE FUSON
ENERGY DOCUMENTS
(APPROVED)
BRES2022 0283-
ENERGY DOCUMENTS
(APPROVED).pdf
1
DOC
1/3/2023
JAKE FUSON
STRUCTURAL
CALCULATIONS
(APPROVED)
BRE52022-0283 -
STRUCTURAL
CALCULATIONS
(APPROVED).pdf
1
DOC
1/23/2023
JAKE FUSON
LETTER OF RELEASE OF
PERMIT
BRES2022-0283 - LETTER
OF RELEASE OF
PERMIT.pdf
1
DOC
2/7/2023
JAKE FUSON
PLANS (APPROVED)
BRES2022 0283 PLANS
(APPROVED).pdf
1
Printed: Thursday, September 14, 2023 10:56:17 AM 7 of 7
CRWSYSTE S
CERTIFICATE OF COMPLIANCE
Project Name: Ryan Remodel
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-07-13T13:13:48-07:00
Input File Name: Ryan_Remodel.ribdl9x
CF1R-PRF-01E
(Page 1 of 10)
GENERAL INFORMATION
01
Project Name
Ryan Remodel
02
Run Title
Title 24 Analysis
03
Project Location
80170 Hermitage
04
City
La Quinta
05
Standards Version
2019
06
Zip code
92253
07
Software Version
EnergyPro 8.2
08
Climate Zone
15
BRES2022-0283
09
Front Orientation (deg/ Cardinal)
100
10
Building Type
Single family
Number of Dwelling Units
1
12
Project Scope
AdditionAlteration
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE 0 1 /03/2023 BY IF
Number of Bedrooms
4
14
Addition Cond. Floor Area (ft2)
0
Number of Stories
1
16
Existing Cond. Floor Area (ft2)
4740
Fenestration Average U-factor
0.32
18
Total Cond. Floor Area (ft2)
4740
Glazing Percentage (%)
26.62%
20
ADU Bedroom Count
n/a
900SF REMODEL
ADU Conditioned Floor Area
n/a
22
Is Natural Gas Available?
Yes
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
Building does not incorporate Special Features
ENERGY USE SUMMARY
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
Space Cooling
IAQ Ventilation
Water Heating
Self Utilization/Flexibility Credit
Compliance Energy Total
4.11 4.25 -0.14
309.28 298.87 10.41
0 0 0
11.94 11.94 0 0
n/a 0 0 n/a
325.33 315.06 10.27 3.2
-3.4
3.4
Registration Number: 421-P010103545A-000-000-0000000-0000 Registration Date/Time: 07/15/2021 10:43 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-07-13 13:14:20
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Ryan Remodel
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-07-13T13:13:48-07:00
Input File Name: Ryan_Remodel.ribdl9x
CF1R-PRF-01E
(Page 2 of 10)
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• NO SPECIAL FEATURES REQUIRED
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building -level Verifications:
• Kitchen range hood
Cooling System Verifications:
• Refrigerant Charge verification required if a refrigerant containing component is altered
Heating System Verifications:
• -- None --
HVAC Distribution System Verifications:
• Duct Sealing required if a duct system component, plenum, or air handling unit is altered
Domestic Hot Water System Verifications:
• -- None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Ryan Remodel
4740
1
4
1
0
2
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area (ft2)
Avg. Ceiling Height
Water Heating System 1
Water Heating System 2
Existing House
Conditioned
Existing HVAC1
4740
12
DHW Sys 1
DHW Sys 2
Registration Number: 421-P010103545A-000-000-0000000-0000 Registration Date/Time: 07/15/2021 10:43 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-07-13 13:14:20
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Ryan Remodel
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-07-13T13:13:48-07:00
Input File Name: Ryan_Remodel.ribdl9x
CF1R-PRF-01E
(Page 3 of 10)
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window and
Door Area (ft2)
Tilt (deg)
Wall Exceptions
Status
Verified Existing
Condition
(E) 10 Wall
Existing House
Default Wall 1992 to
Pres
10
Right
1789.9
141.8
90
none
Existing
No
(E) 100 Wall
Existing House
Default Wall 1992 to
100
Front
927
178
90
none
Existing
No
(E) 190 Wall
Existing House
Default Wall 1992 to
Pres
190
Left
1330.9
245.2
90
none
Existing
No
(E) 235 Wall
Existing House
Default Wall 1992 to
Pres
235
n/a
115
60
90
none
Existing
No
(E) 280 Wall
Existing House
Default Wall 1992 to
Pres
280
Back
1307
636.9
90
none
Existing
No
(E) Roof Attic
Existing House
Default Roof
n/a
n/a
4740
n/a
n/a
Existing
No
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
(x in 12)
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool Roof
Status
Verified Existing
Condition
Attic Existing House
Attic RoofExisting House
Ventilated
4
0.1
0.85
No
No
Existing
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
Area
z
(ft)
U-factor
U-factor
Source
SHGC
SHGC
Source
Exterior
Shading
Status
Verified
Existing
Condition
(E) Window 6
Window
(E) 10 Wall
Right
10
1
43.6
0.55
Tabl
110.6eA
0.67
Table
110.6 B
Bug Screen
Existing
No
(E) Window 13
Window
(E) 10 Wall
Right
10
1
34.5
0.55
Table
110.6-A
0.67
Table
110.E B
Bug Screen
Existing
No
Registration Number: 421-P010103545A-000-000-0000000-0000 Registration Date/Time: 07/15/2021 10:43 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-07-13 13:14:20
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Ryan Remodel
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-07-13T13:13:48-07:00
Input File Name: Ryan_Remodel.ribdl9x
CF1R-PRF-01E
(Page 4 of 10)
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
Area
(ft2)
U-factor
U-factor
Source
SHGC
SHGC
Source
Exterior
Shading
Status
Verified
Existing
Condition
(E) Window 15
Window
(E) 10 Wall
Right
10
1
4
0.55
110.6eA
0.67
110.6 B
Bug Screen
Existing
No
(E) Window 16
Window
(E) 10 Wall
Right
10
1
4
0.55
Tabl
110.6eA
0.67
Table
110.6 6
Bug Screen
Existing
No
(E) Window 16 2
Window
(E) 10 Wall
Right
10
1
4
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 16 3
Window
(E) 10 Wall
Right
10
1
4
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 17
Window
(E) 10 Wall
Right
10
1
15.9
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 17 2
Window
(E) 10 Wall
Right
10
1
15.9
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 17 3
Window
(E) 10 Wall
Right
10
1
15.9
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 18
Window
(E) 100 Wall
Front
100
1
31.4
0.55
Tabl
110.6eA
0.67
Table
110.6 B
Bug Screen
Existing
No
(E) Window 19
Window
(E) 100 Wall
Front
100
1
21.6
0.55
Tabl
110.6eA
0.67
Table
110.6 B
Bug Screen
Existing
No
(E) Front Door
Window
(E) 100 Wall
Front
100
1
75
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 21
Window
(E) 100 Wall
Front
100
1
50
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 6 2
Window
(E) 190 Wall
Left
190
1
43.6
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 4
Window
(E) 190 Wall
Left
190
1
43.6
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 3
Window
(E) 190 Wall
Left
190
1
14.9
0.55
Tabl
110.6eA
0.67
Table
110.6 B
Bug Screen
Existing
No
(E) Window 2
Window
(E) 190 Wall
Left
190
1
8
0.55
Tabl
110.6eA
0.67
Table
110.6 B
Bug Screen
Existing
No
Registration Number: 421-P010103545A-000-000-0000000-0000 Registration Date/Time: 07/15/2021 10:43 HERS P ovider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-07-13 13:14:20
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Ryan Remodel
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-07-13T13:13:48-07:00
Input File Name: Ryan_Remodel.ribdl9x
CF1R-PRF-01E
(Page 5 of 10)
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
Area
(ft2)
U-factor
U-factor
Source
SHGC
SHGC
Source
Exterior
Shading
Status
Verified
Existing
Condition
(E) Window 1
Window
(E) 190 Wall
Left
190
1
40.1
0.55
110.6eA
0.67
110.6 B
Bug Screen
Existing
No
(E) Door
Window
(E) 190 Wall
Left
190
1
75
0.55
Tabl
110.6eA
0.67
Table
110.6 6
Bug Screen
Existing
No
(E) Door 2
Window
(E) 190 Wall
Left
190
1
20
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
Alt: Door 5
Window
(E) 235 Wall
235
1
60
0.32
NFRC
0.18
NFRC
Bug Screen
Altered
No
(E) Window 14
Window
(E) 280 Wall
Back
280
1
40.8
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Door 15
Window
(E) 280 Wall
Back
280
1
80
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 14 2
Window
(E) 280 Wall
Back
280
1
40.8
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 12
Window
(E) 280 Wall
Back
280
1
4.6
0.55
Tabl
110.6eA
0.67
Table
110.6 B
Bug Screen
Existing
No
(E) Window 11
Window
(E) 280 Wall
Back
280
1
48
0.55
Tabl
110.6eA
0.67
Table
110.6 B
Bug Screen
Existing
No
(E) Window 12 2
Window
(E) 280 Wall
Back
280
1
4.6
0.55
Table
110.6-A
0.67
Table
110.6 B
Bug Screen
Existing
No
Alt: Door 10
Window
(E) 280 Wall
Back
280
1
145.1
0.32
NFRC
0.18
NFRC
Bug Screen
Altered
No
(E) Window 6 3
Window
(E) 280 Wall
Back
280
1
43.6
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 7
Window
(E) 280 Wall
Back
280
1
38.6
0.55
Table
110.6-A
0.67
Table
110.6-B
Bug Screen
Existing
No
(E) Window 6 4
Window
(E) 280 Wall
Back
280
1
43.6
0.55
Tabl
110.6eA
0.67
Table
110.6 B
Bug Screen
Existing
No
Alt: Door 5 2
Window
(E) 280 Wall
Back
280
1
60
0.32
NFRC
0.18
NFRC
Bug Screen
Altered
No
(E) Window 4 2
Window
(E) 280 Wall
Back
280
1
43.6
0.55
Tabl
110.6eA
0.67
Table
110.6 B
Bug Screen
Existing
No
Registration Number: 421-P010103545A-000-000-0000000-0000 Registration Date/Time: 07/15/2021 10:43 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-07-13 13:14:20
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Ryan Remodel
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-07-13T13:13:48-07:00
Input File Name: Ryan_Remodel.ribdl9x
CF1R-PRF-01E
(Page 6 of 10)
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
Area
(ft2)
U-factor
U-factor
Source
SHGC
SHGC
Source
Exterior
Shading
Status
Verified
Existing
Condition
(E) Window 4 3
Window
(E) 280 Wall
Back
280
1
43.6
0.55
110.6eA
0.67
110.6 B
Bug Screen
Existing
No
SLAB FLOORS
01
02
03
04
05
06
07
08
09
10
Name
Zone
2
Area (ft)
Perimeter (ft)
Edge Insul.
R-value and
Depth
Edge Insul.
R-value and
Depth
Carpeted Fraction
Heated
Status
Verified Existing
Condition
Slab on)Grade
Existing House
4740
0.1
none
0
80%
No
Existing
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor
Assembly Layers
Default Wall 1992 to
Pres
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O. C.
R-13
None / None
0.101
Inside Finish: Gypsum Board
Cavity / Frame: R-13 / 2x4
Exterior Finish: 3 Coat Stucco
Attic RoofExisting House
Attic Roofs
Wood Framed
Ceiling
2x4 @ 24 in. O. C.
R-0
None / None
0.644
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Default Roof 1978-2013
Ceilings (below
attic)
Wood Framed
Ceiling
2x4 @ 16 in. O. C.
R-19
None / None
0.049
Over Ceiling Joists: R-9.9 insul.
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
Registration Number: 421-P010103545A-000-000-0000000-0000 Registration Date/Time: 07/15/2021 10:43 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-07-13 13:14:20
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Ryan Remodel
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-07-13T13:13:48-07:00
Input File Name: Ryan_Remodel.ribdl9x
CF1R-PRF-01E
(Page 7 of 10)
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
High R-value Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
09
10
Name
System Type
Distribution Type
Water Heater Name (#)
Solar Heating
System
Compact
Distribution
HERS Verification
Status
Verified
Existing
Condition
Existing
Water
Heating
System
DHW Sys 1
Domestic Hot
Water (DHW)
Standard
Distribution
System
DHW Heater 1 (1)
n/a
None
n/a
Existing
No
DHW Sys 2
Domestic Hot
Water (DHW)
Standard
Distribution
System
DHW Heater 2 (1)
n/a
None
n/a
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Heating
Element
Type
Tank Type
# of
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss or
Recovery Eff
1st Hr.
Rating or
Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location
or Ambient
Condition
Status
Verified
Existing
Condition
HeD ter 1
Gas
Small Storage
1
50
0.53-EF
kBtu/hr
0
80
n/a
n/a
n/a
Existing
No
HeDater 2
Gas
Small Storage
1
50
0.53-EF
kBtu/hr
0
80
n/a
n/a
n/a
Existing
No
Registration Number: 421-P010103545A-000-000-0000000-0000 Registration Date/Time: 07/15/2021 10:43 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-07-13 13:14:20
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Ryan Remodel
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-07-13T13:13:48-07:00
Input File Name: Ryan_Remodel.ribdl9x
CF1R-PRF-01E
(Page 8 of 10)
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Compact Distribution
Type
Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1
Not Required
Not Required
Not Required
None
Not Required
Not Required
Not Required
DHW Sys 2 - 1/1
Not Required
Not Required
Not Required
None
Not Required
Not Required
Not Required
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
Name
System Type
Heating Unit
Name
Cooling Unit
Name
Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
Existing HVAC1
Heating and cooling system
other
Heating
Component
1
Cooling
Component
1
HVAC Fan 1
Air
Distribution
System 1
n/a
Existing
No
3
3
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Heating Efficiency
Heating Component 1
Central gas furnace
3
AFUE-78
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency EER/CEER
Efficiency SEER
Zonally Controlled
Mulit-speed
Compressor
HERS Verification
Cooling Component 1
Central split AC
3
9.6
9.7
Zonally Controlled
Multi -speed
Cooling Component
1-hers-cool
Registration Number: 421-P010103545A-000-000-0000000-0000 Registration Date/Time: 07/15/2021 10:43 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-07-13 13:14:20
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Ryan Remodel
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-07-13T13:13:48-07:00
Input File Name: Ryan_Remodel.ribdl9x
CF1R-PRF-01E
(Page 9 of 10)
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
Duct Ins R-value
Duct Location
Surface Area
Name
Type
Design
Type
Supply
Return
Supply
Return
Supply
Return
Bypass
Duct
Duct
Leakage
HERS
Verification
Status
Verified
Existing
Condition
Existing
Distribution
system
New Ducts
40 ft
Air
Distributi
on
System 1
Unconditioned
attic
Non -No
Verified
R-4.2
R-4.2
Attic
Attic
n/a
n/a
Bypass
Duct
Existing
(not
specified)
Air
Distributi
on System
1-hers-
dist
Existing
No
n/a
n/a
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan
Not Required
0
Registration Number: 421-P010103545A-000-000-0000000-0000 Registration Date/Time: 07/15/2021 10:43 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-07-13 13:14:20
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Ryan Remodel
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-07-13T13:13:48-07:00
Input File Name: Ryan_Remodel.ribdl9x
CF1R-PRF-01E
(Page 10 of 10)
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Kenneth Ponce
Documentation Author Signature:
1(e. Vu,teiil, pD-rtce/
Company:
So Cal Title 24
Signature Date:
07/14/2021
Address:
8659 Red Oak Street, Suite I
CEA/ HERS Certification Identification (If applicable):
City/State/Zip:
Rancho Cucamonga, CA 91730
Phone:
909-257-7547
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
TONINO VICAR!
Responsible Designer Signature:
TONING VICARI
Company:
TECTONIC DESIGN
Date Signed:
07/15/2021
Address:
81598 Ricochet Way
License:
City/State/Zip:
La Quinta, CA 92253
Phone:
3107065170
Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the
content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 421-P010103545A-000-000-0000000-0000 Registration Date/Time: 07/15/2021 10:43 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-07-13 13:14:20
Schema Version: rev 20200901