BSOL2021-0202 Plans
L G SCOPE OF WORK GA wesr•'' �""� j•- ' SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 27 x Q CELLS Q.PEAK DUO G6 350 ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 9.45 KW DC STC 8.85 KW DC PTC 8.76 KW AC CEC CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 08/19/2022 BY'] C Nc°°«°® The C'[rus Club alt �,a°,°„ i b 9 M ° v ° 0�°"°,� "e .,.._ si vr.rR°ck Res°N� •.... /+ '' Yo / 1 ' / `d �'" ���.. a X V CONTRACTOR:ZACHARY N GAMEZ STATE LICEaNSEa ucENSE cuss EXPIRE DATE EQUIPMENT SUMMARY 53070 VIACHIAMTE • LA 1uINTA,cA$zz53 * ' ' 27 Q CELLS Q.PEAK DUO-G6 350 Q ,a • 01 SOLAREDGE SE10000H-US INVERTER 27 SOLAREDGE P370 POWER OPTIMIZERS ROOF TILT:O°,18° ARRAYTILT:O° AZIMUTH:158° 2 STORY BUILDING REVISION 2 - BSOL2021-0202 SHEET PV4 REVISED TO REFLECT INSTALLATION 27 ROOF MOUNTED MODULES. PrlVa e luhha esr© 0 pcnWEST stadium C Dune, Nicklaus.- • ' -�„�Y-' -� .ti ,t� _ ryy x` --wti ,•, 4�, - - - F ` PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCYTYPE:V-B APN:777210005 JURISDICTION LA QUINTA CITY OF CODE COMPLIANCE THIS PROJECT SHALL COMPLY WITH STAMP VICINITY MAP PROJECT SITE(33.6635163,-116.2640166) 2019 CA BUILDING CODE 2019 CA PLUMBING CODE 2019 CA FIRE CODE 2019 CA RESIDENTIAL CODE GENERAL NOTES MODULE WATT: 350 W S (27)Q CELLS :9.45 K DUO (S ) SYSTEM SIZE:9.45 KW DC (STC) 8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0°,18° ARRAYTILT:0° MOUNTING HEIGHT:2-STORY 2019 CA MECHANICAL CODE 2019 CA ENERGY CODE 2019 CA ELECTRICAL CODE 2017 NATIONAL ELECTRICAL CODE 2019 ENERGY COMPLIANCE T-24 2019 CITY OF LA QUINTA MUNICIPAL CODE UL LISTED FOR ELECTRICAL AND FIRE SAFETY UL 1703 FOR MODULES AND UL 1741 FOR INVERTERS PER CITY SOLAR REQUIREMENTS NOTE: NO DISCHARGE OF ANY POLLUTANTS TO ANY STORM WATER DRAIN SYSTEM -SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. —THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND LOCAL UTILITY.UTILITY SHALL BE NOTIFIED PRIOR TO ACTIVATION OF SOLAR PHOTOVOLTAIC INSTALLATION. -ALL EXTERNAL CONDUIT AND FITTINGS SHALL BE RAIN TIGHT AND SHOULD BE APPROVED TO USE IN WET AND DRY LOCATIONS. -ALL CONDUITS AND EQUIPMENTS SHALL BE PAINTED TO MATCH THE EXISTING BACKGROUND. -THE PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH CBC SECTION 1609 TO WITHSTAND A MINIMUM OF 130 MPH WIND LOAD -DESIGN COMPLYING WITH LATEST EDITION OF CALIFORNIA ELECTRICAL CODE, NEC AND ALL LOCAL ORDINANCES. -SHOULD USE PROPER GROUND BAR AND KITS FOR GROUNDING -THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING. MECHANICAL OR BUILDING ROOF VENTS. -THE DISTANCE BETWEEN BOTTOM OF PANEL TO THE TOP OF ROOF SHOULD BE MIN 4°. -BACKFEED BREAKER SHOULD BE AT THE OPPOSITE END OF BUS BAR. -INSTALLERS TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. —SEE THE SPECS SHEETS FOR ADDITIONAL INFORMATION. -THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ALL THE REQUIREMENTS OF LOCAL UTILITY. -ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. -A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA . -WORKING DISTANCE AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. -NO VENTS ( PLUMBING, MECHANICAL OR DORMER) TO BE COVERED OR REROUTED AROUND SOLAR MODULES.RELOCATION TO BE DONE ONLY AFTER APPROVAL. DRAWING INFORMATION ""°" °ts°" DRa 6ATE n" s,o" SIGNATURE AND SEAL DATE:08/27/2021 SHEET INDEX - ALL LABELS AND PLACARDS SHALL BE ATTACHED ACCORDING TO NEC AND THE LOCAL AHJ. -METAL CONDUIT AND ENCLOSURE SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE THE BUILDING. -ALL OUTDOOR EQUIPMENT SHALL BE MIN NEMA 3R RATED. PV-1 COVER PAGE PV-2 PLOT PLAN PV-3 ROOF PLAN PV-4 ELECTRICAL LINE DIAGRAM PV-5 ATTACHMENT DETAIL PV-6A LIST OF PLACARDS PV-6B OPTIMIZERS CHART PV-7-11 EQUIPMENTS SPECIFICATIONS -PER CALIFORNIA RESIDENTIAL CODE (CRC) SECTIONS R314 AND R315 SMOKE ALARM AND CARBON MONOXIDE DETECTORS ARE RETROFITTED INTO THE EXISTING DWELLINGS. -ALL PHOTOVOLTAIC EQUIPMENT SHALL BE LISTED BY RECOGNIZED TESTING LAB. -ALL SOLAR ENERGY SYSTEMS SHALL MEET APPLICABLE HEALTH AND SAFETY STANDARDS REQUIREMENTS IMPOSED BY THE CITY AND STATE OF CALIFORNIA. -SOLAR ENERGY SYSTEMS FOR PRODUCING ELECTRICITY SHALL MEET ALL APPLICABLE SAFETY AND PERFORMANCE STANDARDS ESTABLISHED BY CALIFORNIA ELECTRIC CODE,THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, ACCREDITED TESTING LABORATORIES SUCH AS UNDERWRITER LABORATORIES AND WHERE APPLICABLE, RULES OF PUBLIC UTILITIES COMMISSION REGARDING SAFETY AND RELIABILITY. SHEET NAME COVERSHEET SHEET NUMBER PV1 WIND SPEED:130 MPH ROOF 1:10 MODULES ROOF TILT@0° ARRAY TILT@0° AZIMUTH@158° ROOF 2:8 MODULES ROOF TILT@18° AZIMUTH@158° ROOF 3:4 MODULES ROOF TILT@18° AZIMUTH@158° ROOF 4:5 MODULES ROOF TILT@18° AZIMUTH@158° TOTAL:27 MODULES (E)MAIN SERVICE PANEL ROOF ACCESS POINTS CRC R24.7.0 (N)UTILITY DG AC DISCONNECT (N)INVERTER (E) WALL 22,E DRIVE WAY i ROOF AZIMUTH 158° FROM NORTH PLOT PLAN NV CS SP �155'-0" +I NOTE: A 36 INCH WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING NOTE: FLAT ROOF DOES NOT NEED FIRE SET BACKS — (E) WALL 0 RO OF 4 PV2 SCALE: 3/64"=1'-0" ,6 (E) WALL ROOF 2 ROOF 3 o' 3_ { L 2s BACKYARD ROOF ACCESS POINTS CRC R24.7.0 1 / / / /z, / 1- O POINT LOAD CALCULATION PER ARRAY ITEM # OR LN FT WT (LBS) TOTAL WT (LBS) MODULES 27 41 1107 ROOF RAILS 206 1.5 309.0 MOUNTS 64 0.5 32.0 MICRO INVERTER/ POWER OPTIMIZER 27 4.4 118.8 TOTAL WEIGHT 1566.8 MODULE DIMENSIONS 68.50inx41.02 in 19.5 WEIGHT PER MOUNT 24.5 WEIGHT PER SQ FT(LBS/SQFT) 3.0 WIND LOAD CALCS MODULES AND RACKING WEIGHT(W) 1566.8 LBS TOTAL MODULES AREA(A) 526.5 SQFT WIND PRESSURE(PSF) P 35 PSF L=5/16" DIA LAG SCREWS 328 LBS/IN D=LAG SCREWS EMBEDEMENT 2.5 INCH QUANTITY OF LAG SCREWS(Q) 64 QTY ROOF COVERAGE ARRAY AREA 526.5 SQFT ROOF AREA 5492.0 SQFT %COVERAGE 9.6 %<33 LOCATIONS OF DC CONDUCTORS CONDUIT WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE OR HIP OR VALLEY AND FROM HIP OR VALLEY AS DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE THE VENTILATION OPPORTUNITIES.CONDUIT RUNS BETWEEN SUB ARRAYS AND DC COMBINER BOX SHALL BE INSTALLED IN A MANNER THAT MINIMIZES THE TOTAL AMOUNT OF CONDUIT ON ROOF BY TAKING THE SHORTEST RUNS AND MINIMIZED IN THE PATHWAYS BETWEEN THE ARRAYS.DC WIRING SHALL BE INSTALLED IN A METALLIC CONDUIT OR RACEWAYS WHEN LOCATED WITHIN ENCLOSED SPACES IN A BUILDING. CONDUIT SHALL RUN ALONG THE BOTTOM OF THE LOAD BEARING MEMBERS L G / SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 xV--- CONTRACTOR:ZACHARY N GAMEZ STATE LICENSE# LICENSE CLASS EXPIRE DATE 1063010 C-06 02/28/2022 PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN:777210005 JURISDICTION LA QUINTA CITY OF MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO-G6 350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0°,18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY DRAWING INFORMATION EV DESCRIPTION DATE PERMITTING REVISION SIGNATURE AND SEAL DATE:08/27/2021 SHEET NAME PLOT PLAN SHEET NUMBER PV2 EMT CONDUIT UNDER THE MODULES,FMC CONDUIT UNDER ROOF DECK (E)MAIN SERVICE PANEL LNVIHO VIA ROOF AZIMUTH 158° FROM NORTH (N)UTILITY DG AC DISCONNECT (N)INVERTER J INVIACDIMSPI NOTE:TILE STRIP AND INSET OF COMPOSITION SHINGLE IS REQUIRED FOR PITCHED ROOF INSTALL,ROOF 1 IS FLAT TPO ROOF,ROOF2,3,4 IS CLAY TILE 16'9" X8 ROOF JOIIST @16" O r ROOIF 1 2X4 TRUSS@24" O.0 'PE ROOF 4 ROOF PLAN 17' 2" - 9'-4" PV3 SCALE: 1 /16"=1'-0" 20 QTY ATTACHMENT POINTS @ 48" O.C. MAX, USE PROSOLAR FAST JACKS 44 QTY ATTACHMENT POINTS @ 48" O.C. MAX, USE PEGASUS COMP MOUNT 7 2X4 TRUSS 24" 0.0 TY ROOF 2 N to 2'-5„ 27' 3" I I I 2C4 ItRU SS I O.0 TYPE ROOF 3 9' 6" ��0FESS/o, �`(� G T R(i F< QUO 02 �� c W1 C No. C70784 Exp. 06130/2023 111 916- •F CAS-\F� C I\. L_ 16'8"� a 0 0 0 1 1/3*L MAX TYP 48" O.0 MAX 1/3*L MAX TYP -SOLAR STANDARD RAIL TYP 0 0 - (V M co END MOUNTING CLIP,TYP -MID MOUNTING CLIP,TYP TYPICAL RACK MOUNT LAYOUT PV3 2X4 TRUSS@24" O.0 TYPE ROOF 1:10 MODULES ROOF TILT@0° ARRAY TILT@0° AZIMUTH@158° ROOF 2:8 MODULES ROOF TILT@18° AZIMUTH@158° ROOF 3:4 MODULES ROOF TILT@18° AZIMUTH@158° ROOF 4:5 MODULES ROOF TILT@18° AZIMUTH@158° TOTAL:27 MODULES SCALE: 3/16"=1'-0" Q CELLS Q.PEAK DUO-G6 350 ,1, 40.60'> c LO co CD 4 LEGEND JB INV ACD MSP SUB )2( PM A/C - JUNCTION BOX - INVERTER - AC DISCONNECT - MAIN SERVICE PANEL - SUB PANEL - ATTIC VENTS - DORMER VENTS -SKYLIGHT -CHIMNEY - PRODUCTION METER -AIR CONDITON UNIT -SOLAR MODULES ■ -FIRE ACCESS PATHWAY -ELECTRIC METER - COMBINER BOX -CONDUIT ON ROOF M CB L GIB SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 x CONTRACTOR:ZACHARY N GAMEZ STATE LICENSES LICENSE CLASS EXPIRE DATE 1063014 C-46 0212812022 PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE: (760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN:777210005 JURISDICTION LA QUINTA CITY OF MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO-G6 350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0°,18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY DRAWING INFORMATION EV DESCRIPTION ElrIT ESTE PERMITTING REVISION SIGNATURE AND SEAL DATE:08/27/2021 SHEET NAME ROOF PLAN SHEET NUMBER PV3 ELECTRICAL NOTES: 1.) ALL EQUIPMENT TO BE LISTED BY UL OR RECOGNIZED TESTING LABORATORY. 2.) ALL PLACARDS AND SIGNAGE REQUIRED BY LATEST EDITION OF CEC AND NEC WILL BE INSTALLED AS REQUIRED. 3.) ALL THE CONDUIT RUNS SHALL HAVE SUFFICIENT WEATHER PROOF JUNCTION BOXES/COMBINER BOXES. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC AND CEC 5.) ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION AND ALL THE MOUNTING METALLIC EQUIPMENT SHALL BE GROUNDED ACCORDING TO MANUFACTURER INSTRUCTIONS. 6.) ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC ENGRAVED OR MACHINE PRINTED LETTER IN A CONTRASTING COLOR .THE PLAQUE SHALL BE ATTACHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHODS AND SHALL BE UV RESISTANT IF EXPOSED TO DIRECT SUNLIGHT. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) AL THE PHOTOVOLTAIC SYSTEMS AND REQUIRED WIRINGS SHALL BE INSTALLED BY QUALIFIED PERSONNEL ONLY 9.) MICRO INVERTER SHALL CONTAIN GROUND FAULT DETECTION AND INTERRUPTION DEVICES. 10.) ALL WIRES ARE SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. 11.) IF THE EXISTING GROUNDING ELECTRODE SYSTEM CANNOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, CONTRACTOR SHALL INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE AS PER CALIFORNIA RESIDENTIAL CODE CRC SECTIONS R14 AND R15 PROVIDE SMOKE ALARMS ON THE FOLLOWING LOCATIONS: 1.SMOKE ALARM IN ALL SLEEPING ROOMS. 2.CO ALARMS IN ALL SLEEPING ROOMS WITHIN WHICH FUEL BURNING APPLIANCES ARE INSTALLED. 3.SMOKE ALARMS AND CO ALARM IN AREA PRECEDING SLEEPING ROOMS (SUCH AS HALLWAY),AND 4.SMOKE ALARM AND CO ALARM ON EACH STORY LEVEL OF THE DWELLING INCLUDING BASEMENTS AND HABITABLE ATTIC ROOMS SOLAR MODULE SPECIFICATIONS INVERTER SPECIFICATIONS MANUFACTURER / MODEL # HANWHA Q CELLS Q.PEAK DUO BLKG8 350 MANUFACTURER / MODEL # SOLAREDGE SE10000H-US VMP 34.97V NOMINAL AC POWER 10.0 KW IMP 10.01A NOMINAL OUTPUT VOLTAGE 240 VAC VOC 41.21V NOMINAL OUTPUT CURRENT 42 A ISC 10.51A TEMP. COEFF. VOC -0.27%/°K MODULE DIMENSION 68.5"L x 40.6"W x 1.26"D (In Inch) PTC RATING 327.9W STRING #1=14 MODULES STRING #2=13 MODULES CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 08/19/2022 BY"D C DC -DC POWER OPTIMIZER P370 PHOTOVOLTAIC ARRAY JUNCTION BOX AWG #10 PV WIRE IN FREE AIR POS = BLACK NEG = WHITE AWG #6 G = BARE CU (E) 200 A DPB EEDING SUBPANEL PV BREAKER 60 A DPB SAME BRAND AS MSP LOCATED FARTHEST FROM MSP 10.0 KW SOLAREDGE INVERTER AND INTEGRATED DC DISCONNECT EQUIPPED WITH RAPID SHUT DOWN THWN-2 3/4" EMT AWG#10 POS=RED NED=BLACK AWG#8 G=GREEN 60A RATED UTILITY PV AC DISCONNECT (240 V) THWN-2 IN 3/4" EMT (3)AWG #6 L1 = BLAC L2 = RED N = WHITE (1)AWG #8 G = GREEN 0- 0- 0- NEW, IF NO EXISTING GROUNDING ELECTRODE CALCULATIONS FOR CURRENT CARRYING CONDUCTORS: DC CONDUCTOR AMPACITY FROM MODULE TO JUNCTION BOX TO INVERTER IMAX PER BRANCH=IMPX1.25=15X1.25=18.75A AWG#10 DERATED AMPACITY 40X0.65X0.8=20.8A 20.8A>18.75A,THEREFORE DC WIRE SIZE IS VALID AC CONDUCTOR AMPACITY FROM INVERTER TO MAIN SERVICE PANEL INVERTER CURRENT=42A MAX CURRENT=1.25X42=52.5A AWG#6 DERATED AMPACITY 75X0.87X1.0=65.25A, 65.25A>52.5A, THEREFORE AC WIRE SIZE IS VALID 120% RULE ON UPPER BUS BAR MAIN SERVICE PANEL RATING MAIN BREAKER RATING 120% OF MAIN PANEL RATING MAX SOLAR BACKFEED 200A 175A 200*1.2=240A 240-175=65A SOLAR BREAKER SIZE 60A BACKFEED COMPLIES WITH NEC 705.12(D)(2) 60A <65A BI-DIRECTIONAL UTILITY METER 1 PHASE, 3 WIRE 120/240 V (N)175 A DERATED MAIN DISCONNECT EXISTING 400 A RATED MAIN SERVICE PANEL NOTE:NO LOADS AREYET TO PERFO M DERATE CALCS. WE WILL CORDINATE WITH ELCTRICA CONTRACTOR TO MANAGE LOADS BOTH AT MAIN P EL AND SUB PANEL. SO NOT MORE THAN 175A IS ON MAI BUS BAR L G/ SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 x �- CONTRACTOR:ZACHARY N GAMEZ STATE LICENSE# LICENSE CLASS EXPIRE DATE 1063410 C-06 02/28/2022 PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN:777210005 JURISDICTION LA QUINTA CITY OF MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO BLK- G8 350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0° 18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY DRAWING INFORMATION EV DATE REMION SIGNATURE AND SEAL DATE:08/27/2021 SHEET NAME ELECTRICAL DIAGRAM SHEET NUMBER PV4 PEGASUS RAIL L FOOT PROSOLAR FAST 4.5" STANDOFF PVC BOOT FLASHING (PROVIDED BY ROOF CONTRACTOR) REFER ORIGINAL ROOF PLAN FOR DETAILS ON ROOF FRAMING PER STRUCTURAL 2X8 ROOF JOISTS@16"0.0 FOR ROOF #1 5/16"x3-1/2" SS LAG BOLT@ 4' O.0 Max. OVER EXISTING SHEATING AND ROOF TRUSSES AS SHOWN. MIN 2-1/2" PENETRATION TPO ROOF OVER 2X8 ROOF JOISTS@16"0.0 ATTACHMENT TYPE: PROSOLAR FAST JACK (TPO ROOF, ROOF 1) PV5A SOLAR PANEL PORTRAIT, FLUSH MOUNTED PER ROOF SLOPE Y //L///////l //R// 77t.- SCALE: NTS // / 77-1747- / / / -7)17- 6'-0" MAX L G/ SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 xV--- CONTRACTOR:ZACHARY N GAMEZ STATE LICENSE# LICENSE CLASS EXPIRE DATE 1063010 C-06 02/28/2022 PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN :777210005 JURISDICTION LA QUINTA CITY OF MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO-G6 350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0°,18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY DRAWING INFORMATION EV DESCRIPTION DATE PERMITTING REVISION SIGNATURE AND SEAL DATE:08/27/2021 SHEET NAME ATTACHMENT DETAILS SHEET NUMBER PV5A PEGASUS RAIL PEGASUS COMP MOUNT NOTE: (E)ROOF TYPE IS CLAY TILE COMP SHINGLE INSET ON CLAY TILE ROOF IS REQUIRED 2X4 TRUSSES @24"O. C PEGASUS FLASHING (N)COMPOSITION SHINGLE ROOF UNDER ALL MODULES (MAX ONE LAYER) (E)CLAY S TILE ON ROOF 1 OUTSIDE OF MODULE INSTALLATION AREA (E) 1/2" CDX PLYWOOD 5/16"x3-1/2" SS LAG BOLT@ 4' 0.0 Max. OVER EXISTING SHEATHING AND ROOF TRUSSES AS SHOWN. MIN 2-1/2" PENETRATION ATTACHMENT TYPE: PEGASUS COMP MOUNT ((N)COMP ROOF UNDER MODULES, (E)CLAY S TILES ELSEWHERE, ROOF 2, 3 & 4) PV5B SOLAR PANEL PORTRAIT 2X4 TRUSS @ 24" O.0 SCALE: NTS <c,OQROFESS/QNgl T co CD Q. RU02 No. C70784 7 Exp. 06/30/2023 v I\- L G/ SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 xV--- CONTRACTOR:ZACHARY N GAMEZ STATE LICENSE# LICENSE CLASS EXPIRE DATE 1063010 C-06 02/28/2022 PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN :777210005 JURISDICTION LA QUINTA CITY OF MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO-G6 350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0°,18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY DRAWING INFORMATION EV DESCRIPTION DATE PERMITTING REVISION SIGNATURE AND SEAL DATE:08/27/2021 SHEET NAME ATTACHMENT DETAILS SHEET NUMBER PV5B ! WARNING ! ELECTRIC SHOCK HAZARD THE TERMINALS ON LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT (690.13(B) CEC AT ALL "J" BOXES, COMBINER BOX, ENCLOSURES/EMT ENCLOSURES/DISCONNECTS ! WARNING ! TURN OFF PHOTOVOLTAIC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27 C, COMBINER BOX, ENCLOSURE/CONDUIT ENCLOSURE/DISCONNECT CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCE WITH DISCONNECT LOCATED AS SHOWN DLNVIHO VIA INVERTER UTILITY DG AC DISCONNECT MAIN SERVICE PANEL PHOTOVOLTAIC SOLAR ON ROOF PLAQUES SHALL BE PLASTIC ENGRAVED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE WARNING LABELS SERVICE EQUIPMENT WITH POP -RIVETS OR ADHESIVE. WHITE LETTERS ON RED BACKGROUND AND NON -BOLD ARIAL OR SIMILAR FONT.MARKING SHALL BE REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT ! WARNING ! POWER SOURCE OUTPUT CONNECTIONS, DONOT RELOCATE THIS OVER CURRENT DEVICE NEC 705.12 (B)(2)(3)(b)PLACED ON MAIN PANEL/BREAKER LOCATION UTILITY DG DISCONNECT SAFETY SWITCH PV SYSTEM AC DISCONNECT PLACED ON UTILITY DG AC DISCONNECT PHOTOVOLTAIC SYSTEM MAXIMUM VOLTAGE 480V MAXIMUM CIRCUIT CURRENT 27A MAXIMUM RATED OUTPUT CURRENT DC -DC CONVERTER 15A PLACED ON INVERTER DC DISCONNECT LABEL ARNING ! TURN OFF UTILITY DG AC DISCONNECT PRIOR TO WORKING INSIDE PANEL !WARNING! PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE PLACED ON SOLAR BREAKER !WARNING! DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC CEC 705.12 D(3),NEC 690.59 ON MAIN PANEL PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 42 A NOMINAL OPERATING AC VOLTAGE 240 V CEC 690.54 PLACED ON AC DISCONNECT PLACED ON MAIN PANEL r 1 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS WITHIN 3 FT OF MAIN PANEL/AC DISCONNECT/STRING INVERTER !WARNING! PHOTOVOLTAIC POWER SOURCE l ON ALL CONDUITS SPACED AT MAX 10 FT IF DERATING THE MAIN BREAKER AT SERVICE EQUIPMENT LOCATION WARNING MAIN BREAKER SIZE IS REDUCED TO 175A FOR PHOTOVOLTAIC CIRCUIT. DO NOT INCREASE MAIN BREAKER SIZE. RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM CEC 690.56 C(3) PLACED WITHIN 3 FT OF RAPID SHUT DOWN SWITCH SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 P H ON F:760-844-6507 x --- CONTRACTOR:ZACHARY N GAMEZ STATE LICENSE# LICENSE CLASS EXPIRE DATE 1063010 C-06 02/28/2022 PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE: (760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN:777210005 JURISDICTION LA QUINTA CITY OF MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO BLK- G8 350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0° 18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY DRAWING INFORMATION EV DESCRIPTION DATE PERNIIITING REVISION SIGNATURE AND SEAL DATE:08/27/2021 SHEET NAME PLACARDS SHEET NUMBER PV6A L 3IX SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 OPTIMIZERS/MICRO-INVERTERS CHART STRING LAYOUT X CONTRACTOR:ZACHARY N GAMEZ STATE LICENSE# LICENSE CLASS EXPIRE DATE 1063414 8A6 02/28/2022 PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN:777210005 JURISDICTION LA QUINTA CITY OF wvlAcolMSPI/ J 1 - -E1I MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO-G6 350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0° 18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY / / / / / 4 DRAWING INFORMATION RE DESCRIPTION DRAWN B9 PERMITTING REVISION 1 SIGNATURE AND SEAL DATE:08/27/2021 SHEET NAME OPTIMIZER CHART SHEET NUMBER PV6B pin,. Lurid hy Q.ANTUM DUO/ Q.PEAK DUO-G6 340-355 ENDURING HIGH PERFORMANCE THE IDEAL SOLUTION FOR: oofu p amaps on re e!dia nupdinas Engineered in Germany q4fi I I j IF1411 W'. Ur em.rR1 mEmaxel- ID. 400325d- EIIP'a RESEARCH TOO EuSAHLe ?V MOVARS MICR 2020 ❑ CELLS err. a LnEo.¢ap Hsfaar.ro.m n.z n. e1+arTT .m unrenwnap µn 4i.ANTUM TECHNOLOGY: LOW LEVEUSEDCOST OF ELECTRICITY Higher yield par su rfsca area, lower BOB casts. higher power classes. antd an relic t ncy rate of up to 201 %- INNOVA-n VE ALL-WEATHER TECHNOLOGY Optimal yields, whetavar the weather with excellent {CM! -light and temperature behaviour. ENDURING HIGH PERFORMANCE Lon -term yield security with Anti L I D TeOhnolca0y, Anti PI D Technology', Hat-Sput PLuten rt and Traceable Quality Tra.pTM- EXTREME WEATHER RATING High leek aluminum allay frame, certified for high snow (5400Pa) and wind load .(4040Pa). A RELIA1±E INVESTMENT Inclusive12-year product warranty and 25-year linear performance warranty._ STATE OF THE ART MODULE TECHNOLOGY G ANTUM DUO combines cutting Etc9A cell sepe:ation end itlncivertive wring with Q.ANTUM4 Technology. •APT tentGor tale exerrdin g fa1ECjT882905-1:2{115, rnetrlo[f 6-1560V. 168 h] Sae data rledi oa rear ler runner it iformatio+. Rooftop amps on mmensn 1 *xilntria: bL$dIlgs Grouno-TToLavea sorer power rtaras MECHANICAL SPECIFICATION Format 17/113neo sr i¢Y'+pmm r< 32mm (incising frame) ViYatpin 113,9kg Front Cover 3.2mm themara''ypre-atreesed grime with anti- felectiontechrniooy Beck Corer Composle rim Frame Rack anodised alumninlum Cel $v 20 morlrxrtrstsFlne Q At371.1M seller fief cep .1I111ction how 53-I131 mm . 32 6D mm r 18 mm RP:tracfbn rStaelP87, with bypaea dbdee Cable 4mrtltSolar cable, (•]. it50mm.(-]ai150.Tin Connector Straub& MC4. Ha.rwha Q CELLS HOCA, SLTnphen l UT7t, R nhe 05.13. Tongting T1= Cable MS, SMTHY .PA613L; &PBS or Freeds PV29; ]P87 rtr .616.11 1:1ru.ao' rcorat R ErTal Iln... JAArro ELECTRICAL CHARACTERISTICS POWER. CLASS 34U 346 .864 '. IA El I MUhl PEAfannuli CE AT STANDARD TEST CONDFFlom 5. SEC' {POWER TOLERAt1 CE+5 W / AWN Power el AAPPL Pw. M'l 345 34a 355 355 Ghat Circuit Current I. rAI 10.58 1.0.73 LD]9 19-84 Open Circa&Voltage. Va. IV] 40.24 40A9 4023 411,$8 Z Current ert MPP tw. [A] /Dia 10_n 10 J 11333 Vutege et eh PP U jV] 3345 33713 34,07 34.36 EtWcreruyr rl ph] h.1.9A .15.3 e19-5 .1A,6 M HIMUM PERPDRMANCEATNORMAL OPERATNG CONDrFIONs.NMOT' Power al MAP P_ rwi 2scs 258-2 2H1'J@ 2657 iShortClrcwit Currant 1. RI BM. 8.85 1165 874 Open Occult Voltage Voc NJ 3Z.S4 38.17 384i 3a,86 Current ert M PP Jun 141 $,OO 13A4 OM BID Vdtage a1MPP V„rr IV] 31_$L 32_10 3240 e2_60 'Meamuehwrh'yererc so,,,,4.2%; i„, ii,,,,151. at SC:165uw,',P,25..2'C,AM151.rx01.aing1 1EC906 3 3-'800W1r1A.NMCT Spenrurr vk1-s n n.c, 1 e nr.c.,na.. Error ..,..,....r,• . eir-nr•-•-...ap..r AT r .tar r r...A..,T,.w,c r Ij a mina ,a:eeet 9E59s of no.,,ina paver nun erg firsly ear. Tnereefter mat. 0.54 % efearadetron per year. At reed 031 A. of : nrnina power Lpeo 117 years. At ease 9e%d ro rdrnt parer up to years Af daiswthin rree=luar111ttcer- enoes. rLr war enaealn eocordEmce nr:lh the wena:Ry Weed the BLSsaes organ/ ea'mofyexr rerpachye country b I I I I I 1. L I I I I ®rinulrrcErwe,.1 Typca molkIeperiormencc under row vradenoa canettar s n camper -Am to SIC coon gone 1.2i'G, 1000 WJrTP}. T ETA PE 4ATURE COEFFICIENTS -amp ereture Cnefflotent or P„„ o PIM v t3/l4 «OAS Temperature Coafticient all Vae -D33 Nominal M odu1e Opending Temper odor e P EN/xT Nn.roT rq -027 43E3 PROPERTIES FOR SYSTEM DESIGN Maximum System Vdtage Ve,s [Vj 1000(E3 /1060(UL} PV module desalt lcstton CEaa6 I R a R 3 Maximum Ro erse Currant I. PI 20 Fere Rat ing based on ANSI lt1L 1753 C/TYPE2 Ater. deafgn Load, P11e11 / Pall Mai. ten Load, Push I PL!] Wel Pal $03012087. PermirtedModuleTamperatwe 540OMGOD fl^ Conhnuou9 Duty -4 0'C - 485'C QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION VIT Gurney Teal 1.1EC $L215tari3:n3C 3.1131 2DI3; Trail delsrir2e1 carry:An wlrh DIN EN 33631 C E Number M Mochdea per Pellet 32 Number of Palate per Trailer tilt} 26 Number al Pallets per4 a f-IC-CerRa1ner (28 9 Pallet DImanelona {L f W rs t lJ 28 1791 x 1130 x 1200Man Pallet WeIyhl O Nal=lneteaeion tnetruollOns must be tarbWad. Sae the i.siaaailo i end opeoelhty mernai cr contact u r tatludcesarc7ce deperhnentf ar turf er IribrmaifocI on epprwed rnstl-A emm end laeattn- orotct e} i rR .a tie twee (*CELLS GmbH $on re -era 17-21. 0E768 Birtarfa rf-wosent Garrrery 1TE1,+4415J3a04 W99-234441 FAx+a At43x9s68 BI443tOo 1 u Ilea) L, eae3 q-cel scorn1 WE R www..q-celscorl QCELLS L 3IX SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 X CONTRACTOR:ZACHARY N GAMEZ STATE LICENSE# LICENSE CLASS EXPIRE DATE 1063414 CA6 0228I2022 PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN:777210005 JURISDICTION LA QUINTA CITY OF MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO-G6 350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0° 18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY DRAWING INFORMATION RE DESCRIPTION PERMITTING REVISION SIGNATURE AND SEAL DATE:08/27/2021 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET NUMBER PV7 /Single Phase Inverter with HD -Wave Technology for North America SE30013H-1.15 / E380'y01-I1-1U / SE5 ■HHy/-1US / E6000H-US/ _� r � 1 11 11 1� 1f-i_i i f \F }ll �I IH-I 11 {�p�+�}�1y�F �C��/y��y �y�CC��yyy- �L� 5DC0€H-LJS Rl'9 YLr} E YX I -US ¶HOOCH I-U5 �C-���{� I� 3L F EOOF-1-L!S �Cy SLL� rCa���yy� �� JE1141K 1-US OUTPUT _ _ _ _ -----_'__' -- =---a -t.-t.Y= — ,. - - - - xc tax-= =- =S=-== _w T-=t - 5==. INPUT . -_ _ _ -- i=L: . � _, _ __ _ =5'_ •-.,:--- _ - -- - =�=_ - = - -- - - _-� .. --r.—_gym 'im 4e:-- -__ ._ - .G_ 'ra-- -c-: _ :IA - - -- `- -• — - _=I - a.-= _ — - ` _ _ _- - -_ r d_ zt sus=- =-zw-- `-'-=c ors- - 41s-r r.".= =___ = •0 _=2 L=C zti—=-occ. _ _ _ 1- v= • -.---- AL F'EAJUPJ S==r=-- _-=_- :=c.- -_ r_ _ _�L' STANDARD COWt]AN[ -CZ a===eY= INS ALLATI0114 SPEC TICATLON6 — -li. - - =^cr 3 _-D •• _cr -a-T -. - 3fo.rr rr =- k_ :o-= C r '.=ata - 4. A �>t ]C�k� u a rm i'. ^ =^^-a. ara _ . 4 7r A ,Er11 =— f�ri� RoHS Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US } SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US ▪ %dor= ..!'D 0 • _ • •••♦ • • • a i 115 • 9 !tck ••#• r It • • • Optimized installation with HD -Wave technology f Spedfhally designed to wank with if Extremely small power optimizers i Record -breaking efficiency f F IKed vattage inverter for longer stings f integrated arc fault protection and rapid stskrtdown for NEC 2014 and 2017, per arEcre 69211 and 690.12 I UL1741 A certified . for CPLIC Rue 21 grid camp -Hanna solarecig .Corn 52131?13nNI if Built-in module -level monitoring Outdoor and indoor installation ! Optional, Revenue .grade data, ANSE C1220 Class 0"5 (0.5% accuracy) solar= DU\L®GIY ENERG SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 x CONTRACTOR:ZACHARY N GAMEZ STATE LICENSE# LICENSE CLASS EXPIRE DATE 1063414 C-46 0212802022 PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN:777210005 JURISDICTION LA QUINTA CITY OF MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO-G6 350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0° 18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY DRAWING INFORMATION RE DESCRIPTION PERMITTING REVISION SIGNATURE AND SEAL DATE:08/27/2021 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET NUMBER PV8A / Power Optimiser For Australia 3U\L®GIY ENERG SUNLOGIX ENERGY 77585 ENFIELD LN PALM DESERT,CA,9 211E A PHONE:760-844-6507 ModuleAdd-On �} �} �},� �y{� �} P370/P404/P4- 5/ P500/P505 Power Optimiser i • X � Optimiser Model' [T}'pid Module Compatibility) P OD (for PdU3 P485 P500 P505 gm Fr 6I�ce11 60 and 72-cell and 72-cell. short (for high -voltage [far 96-cell (for higherI* moLdalr ) strings madLrles} modules) current modules] ForAustralia d u I d d n CONTRACTOR:ZACHARY N GAMEZ STATE LICENSE4 LICENSE CLASS EXPIRE DATE ��,a C>6 oz D tNPUT th PROJECT NAME AND ADDRESS TOM & JULIE RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCYTYPE:V-B GROUP:R APN:777210005 JURISDICTION QUINTA CITY OF Y-:===7 _ _ Z.:: E..: E P370 P404 P485 P500 P505 70 0 F,Y^ � 4 111:11 _`� ___ • r : a-.:_ r• 2 OUTPUT DURING OPERATION (POWER DPTIk115ER CONNECTED TO OPERATING SOLAREDGE INVERTER) TEAR T 1 � II'M vcx- J — . _ „a_ _ _- I �� _- __ ouTPUT DURING STAND RV (POWER OPTIMISER DFSCDNNECTED FROM SO A EDGE INVERTER OR SOLAREE]GE I hIYE RT1 R OM- KLA STAN1}ARD CDMPI_tAN 1 VI MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO-G6 350 SYSTEM SIZE:9.45 KW DC (STC) :8.76KWAC(CEC) (1)INVERTER:SOLAREDGE SE10000H-US OPTIMIZER: P370 AZIMUTH:158° ROOFTILT:0°,18° ARRAYTILT:0° MOUNTING HEIGHT:2-STORY `yc'e _CEbs.:=[riS=i[_; I _ � , ;mars I� ': � - ,- in _-m _-1:!-E .-1^2 7:/ IhISTA11ATZDN SPECIFICATIONS(27)POWER ram,=_ _=.-- __ _ '__ nc3.=:••.a_r4. .Z.x' -1 = -3 a3: 1�c= 223C==K '= i2=1f'•S=Ksi4 •12EK'=tx== -. - - - --:_.m.,_ A-c 75G ri -• T Vit.. _-x V 11 , =_ ,-.-, - . I 12 rn DRAWING INFORMATION REV DESCRIPTION BY o,P ____---_ — I�E.0 €,1.gr' PERMITTING sd -_.ti . _ -_ -- _ - __ .- REVISION - �. _ .- __.— _--- --_ _- -_ { _- --._ ___ : ___.. --- : =ch� :.-r=n�= Rif power optimisation at the module -level .Y."'wZ.1G= - _ - - 'r- .• 2L=—P.i.V ... .r.,,=J='=?23• *I_+rs..-: :7=a:_ =.--.-. -;.:4v re...7=-.;F =+_- -" _ G=ti sue:- aa- - - —:-MI:.ssa:mt.2mu f = 3--. --- ?"-: 7 : Z{ yJ' S =" -= _ C r.-_- - � _ _ ,.0 SpecifnatIty de5ig lei to work with S Iaf Ed e i r iCdtrie system design for maximum space Irrre7ecs utilization SIGNATURE AND SEAL DATE:08/27/2021 Single Phase PV Design Using a SSoiareJge Imrertie Single. PhOSG ND -WAVE Three Phase Residential!'Commeieia; Three Phase if Up to 25% more energy I , 352 installation vrlth a 53Pg1e bolt maintenance module 1 l with - _ = r-- -=f'-1 ---=e-x-,r. -• - -- I Superior efficiency('9f959G) generation level monitoring -_ .�,=-- - -:_ --" - __-- J 5- ' =.- Y'~' 1 kriitigates aII typli. of rno iul rr_ismatch- _ loser fmanufacturing tolerance to partial 1 k odiie-level voltage shutdown for installer - j -r-er. Z xz:s - 5'�laifEBg!firefighter t `� _ -- - - - • - - � -- -_.. : �-�.. �� r oiw�� --z "_s � •:. �'� rasrit � �Tr F�,{4= -'.P ---'T'a°' =` - . 1 __-- ----:-.r.:.:rris . -_--was:= __ m-,- :;.-- .:.s-: - :-:. _ .=s -'- 1 - _ _' c-� = -ti=ire- -_. : _ _ _ __ --:spy ..�_ �- a- - __- x'i-...-o^^x-a�r.r^^•-�:^_•7 :, 4_ r-: L z___ �J orn solar- -e -.x -- �Ftis}c51. --r,f,---- - _--..I=r•S l .•Fr.F.L.a.P> i� rrn��e Z rm.wa -r_r,•u:' S:,. .-.e+�C -L z.vrc-M, vim- rt:nr-rseY«or me-ri b 4=.1 1W.17G:..L 94 c:-ormw:�.J - -r C E Rofi S lr- • • ;. SHEET NAME EQUIPMENT SPECIFICATIONS SHEET NUMBER PV8B RAIL SYSTEM Instant Bonding The N-S Bonding Jumper bonds row to row with no tools. One Clamp Anywhere The Multi -Clamp works as mid- or end -clamp, and fits standard 30-40mm frames. Lifetime Wire Management Open rail channel holds and protects wines. Clamps won't pinch wires after tightening_ Bonding Structural Splice Connect rails instantly, without tools, interference or limitations. Next -Level Solar Mounting A complete system for hassle -free rooftop installation, from watertight mounts to lifetime wire management. Simplicity 1f2`sodket for everything. One clamp for mid or end. No tool splicing and bonding. Easy wire management Code Compliant UL 27031isted I-TR-AE-001-2012 listed Class Afire rating for any slope ASCE 7-1 6 PE Certified Premium Aesthetics The narrowest panel gap available. Optional Hidden End Clamps and End Caps provide a flush lock onthe edge ofthe array. Watertight for Life Secured on industry -leading Pegasus Mounts, for composite shingle and tile roofs. Backed by a 25-year warranty_ Pegasus Solar Inc 1506 West Ohio Avenue, Richmond, CA 94804 I T: 510.2 I 0.3797 I www.pegasussolar.com PEGASUS SOLAR' Available in 14' and T lengths for easy layout end shipping. Open -charmed design holds MC4 cannactara, PV vire end trunk cables. Bieck and M+II finish M uhti-( lamp Fits 30-40mm PV frames. es mid- or e nd -clamp. Twist -looks into position: doesn't pinch wines in rail. Bonds modules to resit: UL2703 listed e s reusable MLPE Mount Secure. and Fonda most rniuoanrartess end cptimioaeatnril. Ca usertoreand vans easily Mire underneath after irefallelion. UL2703 fisted as reusable. Pegasus Max Rail Maximumatrength design. Meets spedfieetionsfarhigh snow -coed and hurricane zones. 81arkand MI finish Hidden End Clamp Offers premium edge appearance. Preinatelred pull -tab gripe rail edge, allowing easy. one -fiend installation. Tucks away for reuse. Cable Grip Secures -Four P[fwires ortWo trunk cables- Stainless-61mA backing provides durable grip. ETIminetea sagging Ce UL 27i0` •UL2703, 3,Editian 1 IRn�I • LTR-AE-001-2012 • ASCE 7-16 PE certified C US • Class A fire rating for any slope roof Quickly csiculete the. mostelhciern layout spans and materiels needed te.uit yourfob, Visitthe Pegasus Customer Poral. pegawswlacoom/porta€ axarna pending. All ngbto •ewrerd-02921 Pazienua cotes Inc. RAIL SYSTEM Splice and Max Splice Dovetail T-bolt Instl/a by hand. Dovetail shape for extra strength. Works over mourris. Usco IT socket Structurally connects end bonds refs automatically; UL2703 listed as reusable. Ground Lug Holds or8AWGwire. Mounts on top or side of reiL Assembled on MLPE Mount. UL2703listed as reusable. Wire Clip Hand operable. Holds wires in channel. Wont slip. NZ. bonding Jumper installs by hand, aliminetes row -to -row capper wire. UL2703 Bated as reusable only w ith Pegasus Ral. End Cap and Max End Cap FrtD flush to PV module end hides raw or angled cuts. Hidden drain quickly deers w ater from rail. LOAD P SNOWiSFI 0 35 30 Wirroim it ;r'.;., m : 32' ,i. a' b' 120 160 190 140 160 190 160 190 45 19D 70 190 110 190 - PEGASUS R.iL -PEG/SUSMA% NAIL. Forreierenee only - .pen- aocee ere celculetec ne Alt-E 7-16. fora Bebk Roof. Ecpo urn Ceiegory B. 7-20.deg roof angle, &Ph meen roof he:gM with na4—mpaoed modu[ee Fn. PE cerdted opanted:Am, vioirwww-pe©aouomler.onmf.pano. Pegasus Solar Inc .1 506 West Ohio Avenue, Richmond, CA 94804 I T: 510.210.3797 I www,pegasussolar.com L 3IX SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 x CONTRACTOR:ZACHARY N GAMEZ STATE LICENSE# LICENSE CLASS EXPIRE DATE 1063414 846 02/28/2022 PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN:777210005 JURISDICTION LA QUINTA CITY OF MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO-G6 350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0° 18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY DRAWING INFORMATION RE DESCRIPTION PERMITTING REVISION SIGNATURE AND SEAL DATE:08/27/2021 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET NUMBER PV9 L G/ LiowCOST r1'�� I\TS'I' 11 �J + 17Asy SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHvE7608446507 __, CONTRACTOR:ZACHARY N GAMEZ Fastjack cIiiiir.JK STATE LICENSE# LICENSE CLASS EXPIRE GATE 1063414 C-06 02/28/2022 �.� �R•a�,d4, POLYMER INNOVATION .3, Fast-JackV % p � ak ack The FastJack- `R ChemLinkTM combination is waterproof and compatible PROJECT NAME AND AOORESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN:777210005 JURISDICTION LA QUINTA CITY OF with most roof types, making it the go -to flat roof solar and other rooftop Commercial E-Series Residential E-Series equipment mounting solution for today's contractors. - . Featuri n ■ ■ Fastack Eerier \\11\ ChemLink 3" E-Curb 1 4-1/2" Commercial FastJack E-Series (P/N: CFJE-450-18) ChemLink 1-Part Filter(27)O 2 6" Commercial FastJack E-Series (PIN: CFJE-600-18) - ChemLink M-1 Sealant 3 8" Commercial FastJack E-Series (PIN: CFJE-800-18) 1 3" FastJack E-Series (PIN: FJE-300-18) 4 10" Commercial FastJack E-Series P/N: CFJE-1000-18)2 4-1/2" FastJack E-Series P/N: FJE-450-1$ ( ( } 5 12" Commercial FastJack E-Series (PIN: CFJE-1240-18) 3 8" FastJack E-Series (PIN: FJE-600-18) _ Includes: 1-1f4" OD Solid Aluminum post with 318" Top Includes: 1" OD Solid Aluminum Post and 1.5" OD _ - Threaded, 2" E-base. Hardware sold separately. E-base. 5/16" x 3-1/2" Lag screw, 3f8" SS Washer, Packaged 18 per box and 318" x 314•' SS Hex Bolt • Packaged 18 per box • MODULE WATT: 350 W CELLS O.PEAKDUO-G6350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0°,18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY DRAWING INFORMATION ' • - ll oEs 6P.oN av DATE f r _ 1-Part and M1 Ratios ChiM LINK POLYMER INNOVATION PERMITTING REVISION ._., • r3' s.r • - •:'w''' • - ;1 , .i'... - � �: _ -_ CFJE: (1) Tube 1-Part for (2) E-Curbs (1) Pouch 1-Part far (12) E-Curbs (1)Tube M-1 far (3) E-Curbs11 Y SIGNATURE AND SEAL DATE 08/27/2021 5"_, _CI\ ! ,'+4 +: • _ , Mar a ;; ;Ai., :,r 7 } ` 'Z` ' , `. -4 h w ;' '^ 4, ;,I _ - -� 'y '" ��d3 { r' " s`� r `:' '�s=. FJE: 21 Tubes 1-Part for 3y E-Curbs (1) Pouch 1-Part for (10) E-Curbs (1) Tube M-1 for (3) E-Curbs l 1 ChemLink 1-Part Pouch (P/N: A-ChemLink 1-Part Pouch) 2 ChemLink 1-Part 10,1oz Tube (P/N: A-ChemLink 1-Part) Waterproof J Low Cost 1 High Quality ® I Easy -to -install Pr 0 01 3 ChemLink M-1 10,1oz Tube (PIN; A-ChemLink M-1) ChemLinkE Curb (PIN:J#-chernLink 3"E-curb) a r Hound, 3" diameter, does not include f 4-1 adhesive/sealanf Prosa f a r or 1-Part sealant SHEET NAME EQUIPMENT SPECIFICATIONS ChemLink Products Sold Individually and COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2017; All fntormatian contained in this brochure is property of Professional Solar Products (PSP). COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2017: All information contained an this brochure is pr 1ggqUwitli5ts (PSP)• FasttacIC Is.a registered trademarks for PSP and are covered under U.S. patent #6,3fJ0,481. (v 1.0) FastJack is a registered trademarks tar PSP and are covered under U.S. patent #6,360.491. iv 1.0) SHEET NUMBER PV10 PEGASUS SOLAR` A BETTER DAY ON THE JOB TILE REPLACE MOUNT Flashing slides into place then past twist-Ineks into position Gain one roof tile per mount. Ehm mate traps to the tile yard to purchase replacement tiles EASIER TILE INSTALLATIONS Pegasus Solar's The Replace Mount eliminates grinding of tiles and gives you extra tiles to replace broken tiles_ Reduce fatigue and increase crew productivity by making installations easier and faster_ 25-year Warranty Manufactured with advanced materials and coatings to outlast the roof itself Code Compliant Fully IBC/CBC Code Compliant Exceeds ASCE 7-10 Standards Tested to AC286 s� Universal Supports rails, shared rails, rail -less and module integrated_ Frts any tile thickness and batten or batten -less roofs_ S-flashing works on concrete or clay tiles_ Kit Packaging Flashing kit Includes flashing, post, mounting bolt and EPDM boot Sled kit includes universal sled, SS fags and base Hashing (optional)_ TILE REPLACE MOUNT 1. Remove tile to be replaced and locate rafter. 3. Slide replacement flashing under left and up -roof tiles, ensuring post hole lines up with sled channel_ Fla -tile Replace Kit 5 Tife Replace la W Tile Replace Kit Sled Kit Ors M 2 instill sled aver optional base flashing and drive lag screws to required embct me ': . . {per allay and star.: s as required by the Al-!J_ 4. Insert post with T-Bolt into sled channel_ Once engaged, rotate past clockwise to tighten T-bolt Install EPDM boot over post and snug to flashing_ SpecrficatiCsnr. SKit Tie Type Tie Replace Marking Kit (Fiat* S & W) PSTR-FF Flat#le PSTR-FS S-tile & Clay tile PSTR-FW W-tle Steil Kit GUnivemai) PSTR-SE Arsy PSTR-50 Hardware irduded Flashing. Post. Mounting Batt, EPDM Boot Sled, 5116' S5 Sled. 5116" SS La Lags, Base Flashing InstaQ App4on Certificafrons Material KM Quantity Boxes Per Pallet Raiil, fired Ral, Rag -less, Module lrrtegrated 1®C, ASCEI5EI 7-10, AC286 Painted Csalvalume Plus, Aluminum 12 28 Galvanized Steel (min G165 equivalent) 6 56 Parana Par -dries. / L righm reserved. 02018 Pegasoe Sodar Inc Pegasus Solar Inc • 100 West Ohio Avenue, Richmond, CA 94804 • T: 510.730_1343 • www.pegasussolar.com Pega:u: Solar Inc • 100 West Ohio Avenue. Richmond, CA 94304 • T: 510.73,0_1343 • www-pegasussolar.com D-'U\LOG IY ENERG SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 x CONTRACTOR:ZACHARY N GAMEZ STATE LICENSE# LICENSE CLASS EXPIRE DATE 1063414 C-46 02/28/2022 PROJECT NAME AND ADDRESS TOM & JULIE WILLIAMS RESIDENCE 53070 VIA CHIANTE LA QUINTA,CA,92253 PHONE:(760)409-6173 OCCUPANCY TYPE:V-B GROUP:R APN:777210005 JURISDICTION LA QUINTA CITY OF MODULE WATT: 350 W (27)Q CELLS Q.PEAK DUO-G6 350 SYSTEM SIZE:9.45 KW DC (STC) :8.85 KW DC (PTC) :8.76 KW AC (CEC) (1)INVERTER:SOLAREDGE SE10000H-US (27)POWER OPTIMIZER: P370 AZIMUTH:158° ROOF TILT:0° 18° ARRAY TILT:0° MOUNTING HEIGHT:2-STORY DRAWING INFORMATION RE DESCRIPTION PERMITTING REVISION SIGNATURE AND SEAL DATE:08/27/2021 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET NUMBER PV11