BPOL2021-0095 PlansBPOL2021-0095
19
9',
25'
7'
30'
Eisenhower Drive
CI TY OF LA QU N TA
BULDNGOVISON
REVI EVED FOR
COCE CCIfPLI AV CE
Bin J.ANAYA E: 03/25/2021
Pool Enclosure Per City Code
Existing Perimeter wall 60 inches
, minimum height
PLEASE PROVIDE WET STAMPED POOL ENGINEERING
SHEET ON SITE FOR INSPECTIONTT
9'
7'
0
0
m
-o'
12'
WD 3'-6"
Pool Light
Skimmer
WD 5'-6"
+18„
13'-6"
Exist alarms to be installed on all
doors with access to be pool
Provide a #8 copper wire around
the pool connected at 4 points -
Maximum 18" from water's edge.
ALL CONSTRUCTION IS TO CONFORM TO THE CURRENT CODES:
ELYON/ POOL AND SPA AT SIDE YARD. TWO 2urrent Adopted Model Codes:
DROWNING SAFETY FEATURES AND
BARRIERS REQUIRED TO BE INSTALLED AT
PRE -PLASTER INSPECTION. PLEASE PROVIDE
WET STAMPED POOL ENGINEERING SHEET
ON SITE FOR INSPECTIONTT FIELD VERIFY.
NEW EQUIPMENT MUST BE LOCATED IN AN
APPROVED LOCATION EITHER WITHIN THE
REAR YARD SETBACK OR 5' MINIMUM FROM
THE SIDE P/L--FIELD VERIFY. 2019
CALIFORNIA BUILDING CODE.
Gate Shall be Self Closing Self Locking
and Swing away from the pool area 60
inches high barrier.
Gas
Elec
GAS GAS GAS
Heater vent to terminate a minimum of
4ft away from open side of window
GAS
GAS
GAS
GAS
172 LF 2" Poly-Ethelenes Gas
line with 10 AWG yellow Tracer
39 LF 1" electrical conduit for 10
gauge wiring to pool equipment
GAS
GAS
co
o
o
GRAPHIC SCALE
1 /8"=1'-0"
0' 8'
16' 24'
Note:
All measurements to be field verified.These are field
measured dimensions for approximate layout and
estimating only. All construction to perform their own
field measurements.
Gate Self latching and spring closer
Gate Latching Requirements
ALL GATES MUST SWING AWAY FROM THE POOL, BE SELF -CLOSING & SELF -LATCHING
Protective shield o
with no
greater
Release
to ated
openings
than 3/4"
mechanism shall be
on "pool" side.
fencing
Release mechanism may be
Located On either side If
60"+ above grade.
CONDITION 1
RELEASE MECHANISM
LOC:ffTCD LESS THAN 60"
ABOVE GRADE
284-004 Rev. 06/2016
CONDTTI.ON 2
RELEASE MECHANISM
I..ocATED Go- OR MORE
ABOVE GRADE
Release mechanism shall he
located at least GOi.nches
above grade.
TYPICAL SELF••i,ATCHING
GATE and SPRING CLOSER
4080 Lemon St, 9eh Floor • P.G. Box 1629 • Riverside, CA 92502
Phone (951) 955-1800 • Fax (951) 955-1806
i
•
•
2019 California Residential Code:
2019 California Electrical Code:
2019 California Mechanical Code:
2019 California Plumbing Code:
2019 California Green Code:
2019 California Energy code:
Based on the 2018 International residential Code (IRC)
Based on the 2017 National Electrical Code (NEC)
Based on the 2018 Uniform Mechanical code (UMC)
Based on the 2018 Uniform Plumbing (UPC)
California Building Standards Commission
California Energy Commission
• All pool equipment shall be seismic armed per city code
• An alarm installed on all doors with direct access to the pool. the alarm shall sound continuously for
a minimum of 30 seconds within seven seconds after the door and its screen, if present, are opened,
and be capable of providing a sound pressure level of not less than 85 dba when measured indoors
at 10 feet. The alarm shall automatically reset under all conditions. The alarm system shall be
equipped with a manual means, such as a touchpad or switch, to temporarily deactivate the alarm
for a single opening. Such deactivation shall last no longer 15 seconds. the deactivation switch shall
be located at least 54 inches above the threshold of the door. Man door leading from garage to pool
area must be self -closing and self -latching with latching mechanism located a minimum of 54 inches
above the threshold of the door.
• Barrier requirements to be installed and inspected prior to plastering or filling the pool/spa/hot tub
with water.
• For spa equipment please see attached sheet
MUNICIPAL CODE REQUIREMENTS:
A. Approved temporary sanitary facilities (I.E. Chemical toilets shall be on the construction site prior to
request for first inspection). (Health and safety code, section 5416)
B. Contractor and or owner shall provide a trash bin to insure proper clean up of all building materials.
(Ordinance NO. 262 of the city municipal code)
C. Storage of building materials or debris shall be confined to the lot on which the permit is issued.
Adjacent vacant properties may not be utilized for this purpose unless written permission of the
owner is on file with this office. the public right-of-way shall be maintained in a clear condition at all
times. (City municipal code, chapter 8.02)
D. Address numerals shall comply with City ordinance NO. 1006. You may request a copy of the
ordinance at the building department.
E.
F.
ELECTRICAL
There is no outdoor surrounding lighting or low voltage lighting, including landscape lighting.
There is no overhead utility/service lines over construction area or SPA. Utility/service lines must be
in compliance with CEC table 680.8 for overhead conductor clearances.
Equipment Notes
• All Equipment Shall be Seismically Anchored
• Masonry equipment wall shall be built per city standard specifications
• all GFI outlets will be weather and tamper proof
• All outlets supplied by single-phase, 15A and 20A, 125V or 240V Branch Circuits for swimming pool
pump motors are required to have GFCI protection
• Provide 36" working clearance for the pool Equipment motors are required.
Notes:
• Installation of pool systems and equipment will comply with section 114-Mandatory Requirements.
• Exist Alarms to be installed on all doors with direct access to the pool.
• Pool Heater,Pool equipment shall be installed per manufacture's recommendations and in
accordance with local regulations.
• Spa to be equipped with Anti -Entrapment Device (Sec. 1404 Federal Swimming Pool and Spa Drain
Cover Standard).
• Provide location and Anti -Entrapment /Vortex covers meeting current standards of the American
Society for testing and materials (ASTM) or The American Society of Mechanical Engineers (ASME).
Identify a minimum 3 feet separation between all drains and note Hydraulically balanced.
• Led Lights require water bounding
• Pool Heater/pool equipment shall be installed per manufacturing installation specifications
• Provide adequate workspace around electrical equipment per 2019 CEC 110.26
Pool Safety Barrier Notes
• Exit Alarms
• Self -closing Doors
• Self Latching Doors
t�
d
7:5
(7)
d
a)
a)
a)
0
>1%
CV
'� CO
0 LO
CV
S. C
(1)V
(3)
0
_c
Cu co
.cn AE.
w
O 0
co co
J
Design:
Drawn: DN
REV
DATE
0
03/15/21
1
NORTH
SCALE: 1 /8"=1'0"