Loading...
FA2018-0005ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT COMTRON SYSTEMS P O BOX 13470 PALM DESERT CA 92255 JOHN@COMTRON1.CO M BILL TO COMTRON SYSTEMS P O BOX 13470 PALM DESERT CA 92255 JOHN@COMTRON1.CO M CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PUBLIC COUNTER VISIT AARON HICKSON 6/28/2018 6/28/2018 MONTE SORENSEN PICKED UP PLANS FOR REVISIONS PRINTED CORRECTIONS FOR HIM.FOLDER ON REVISION REQUESTED SHELF WHEN RETURNED RESUBMITTAL AARON HICKSON 6/29/2018 6/29/2018 MONTE SORENSEN FROM COMTRON RESUBMITTED CORRECTIONS CONDITIONS Description: PGA WEST MULTI PURPOSE / COMMERCIAL SPRINKLER MONITORING Type: FIRE ALARM Subtype: COMMERCIAL - SPRINKLER MONITORING Status: FINALED Applied: 6/15/2018 RCA Parcel No: 775220027 Site Address: 55965 PGA BLVD LA QUINTA,CA 92253 Approved: 11/9/2018 EGO Subdivision: PM 24995 Block: Lot: 4 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 11/9/2018 EGO Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Wednesday, January 18, 2023 4:31:27 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2018-0005 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL CONTRACTOR COMTRON SYSTEMS P O BOX 13470 PALM DESERT CA 92255 JOHN@COMTRON1.CO M OWNER LQR GOLF 1 BUSH ST STE 1100 SAN FRANCISCO CA 94104 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FUNCTION TEST EGO APPROVED SPRINKLER MONITORING EGO APPROVED FIRE FINAL**EGO APPROVED FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS 101-0000-42421 0 $156.00 $156.00 6/15/18 R36637 16432 CHECK COMTRON SYSTEMS AMA FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS PC 101-0000-42420 0 $234.00 $234.00 6/15/18 R36637 16432 CHECK COMTRON SYSTEMS AMA Total Paid for FIRE FEES: $390.00 $390.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 6/15/18 R36637 16432 CHECK COMTRON SYSTEMS AMA Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/15/18 R36637 16432 CHECK COMTRON SYSTEMS AMA Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$405.00 $405.00 Printed: Wednesday, January 18, 2023 4:31:27 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2018-0005 SPRINKLER MONITORING EGO 7/10/2018 7/10/2018 PARTIALLY APPROVED FIRE ALARM ROUGH WIRE INSPECTIONS APPROVED. REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) REYNA CAMARENA 6/15/2018 6/15/2018 6/15/2018 COMPLETE 1ST FIRE (2 WK)EDGAR GONZALEZ 6/15/2018 6/29/2018 6/28/2018 REVISIONS REQUIRED FIRE ALARM - WATERFLOW MONITORING SYSTEM - PLAN REVIEWYour plans have been reviewed by the Riverside County Fire Dept. and require the following corrections listed below before approval.1.) Please correct address on plan. Actual site address on building plan is listed as 55-965 PGA BLVD.2.) List control valve on symbol legend or remove if it is not being installed.3.) Correct node point 5 and 4 on plan. Node point 5 is listed as a PIV tamper switch on site yet node point 4 has listed information for outside wiring on wire schedule. Please correct or clarify. 4.) List node point 5 on wire schedule. 5.) Show wire runs on plan. It should still be shown on the "exploded view."6.) List battery(ies) that will be utilized on install on FACP schematic. 7.) Show fire alarm annunciator on FACP's exploded view or remove and provide clarification on why it is not being installed. 2ND FIRE (2 WK)EDGAR GONZALEZ 6/29/2018 7/6/2018 7/3/2018 APPROVED- CONDITIONS CORRECTIONS SUBMITTED BY COMTRON PARENT PROJECTS Printed: Wednesday, January 18, 2023 4:31:27 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2018-0005 ATTACHMENTS BOND INFORMATION 2ND FIRE (2 WK)EDGAR GONZALEZ 6/29/2018 7/6/2018 7/3/2018 APPROVED- CONDITIONS FIRE ALARM/WATERFLOW MONITORING - PLAN REVEIW - APPROVAL The fire alarm plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1.) A rough-wire inspections shall be conducted before concealment of structural members for wire verification. 2.) A function test is required on all installed equipment is required to be witnessed by Fire Department. All signals shall be verified before final approval is granted. 3.) A document box is to be installed at FACP panel with approved plan and equipment keys. 4.) Plan did not indicate communication method. Fire alarm equipment is required to be monitored by 2 phone lines or approved cell communicator. If cell communicator is to be utilized, an as built drawing shall be submitted before final for review. 5.) All j-boxes and electric boxes serving fire alarm system shall be red in color or labeled. 6.) Compartment/room containing fire alarm equipment shall be labeled "FACP" on exterior side. 7.) NFPA 72 Record of Completion shall be provided at Final Inspection. Printed: Wednesday, January 18, 2023 4:31:27 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2018-0005