FA2019-0002ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT ALARMCO SECURITY SYSTEMS 451 KANSAS ST REDLANDS CA 92373 BILL TO ALARMCO SECURITY SYSTEMS 451 KANSAS ST REDLANDS CA 92373 CONTRACTOR ALARMCO SECURITY SYSTEMS 451 KANSAS ST REDLANDS CA 92373 OWNER STATER BROS MARKETS 21700 BARTON RD COLTON CA 92253 CONDITIONS Description: STATER BROS / FIRE ALARM REMODEL FOR WHOLE STORE Type: FIRE ALARM Subtype: COMMERCIAL - FIRE ALARM SYSTEM Status: FINALED Applied: 1/15/2019 AMA Parcel No: 604050031 Site Address: 78630 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 1/30/2019 EGO Subdivision: PM 25865 Block: Lot: 2 Issued: 2/6/2019 SSW Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 4/11/2019 EGO Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE ALARM SYSTEMS 101-0000-42421 0 $480.00 $480.00 1/15/19 R43129 19224 CHECK ALARMCO SECURITY SYSTEMS AMA Printed: Wednesday, January 25, 2023 3:37:05 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2019-0002 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH-WIRE INSPECTION EGO 2/25/2019 2/25/2019 PARTIALLY APPROVED ROUGH-WIRE INSPECTION EGO 3/21/2019 3/26/2019 APPROVED FUNCTION TEST EGO 3/21/2019 3/26/2019 NOT READY FUNCTION TEST EGO 4/11/2019 4/11/2019 APPROVED DUCT DETECTORS/VELOCITY EGO 4/11/2019 4/11/2019 APPROVED 24 HR. BATTERY TEST EGO 4/11/2019 4/11/2019 APPROVED FIRE FINAL**EGO 4/11/2019 4/11/2019 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE ALARM SYSTEMS PC 101-0000-42420 0 $560.00 $560.00 1/15/19 R43129 19224 CHECK ALARMCO SECURITY SYSTEMS AMA Total Paid for FIRE FEES: $1,040.00 $1,040.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 1/15/19 R43129 19224 CHECK ALARMCO SECURITY SYSTEMS AMA Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 1/15/19 R43129 19224 CHECK ALARMCO SECURITY SYSTEMS AMA Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$1,055.00 $1,055.00 Printed: Wednesday, January 25, 2023 3:37:05 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2019-0002 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 1/30/2019 EDGAR GONZALEZ FA2019-0002 - STATER BROS - 78-630 HWY 111 - FIRE ALARM (COA).docx FA2019-0002 - STATER BROS - 78-630 HWY 111 - FIRE ALARM (COA).docx 1 BOND INFORMATION 1ST PERMIT TECH (1 DAY) ARMANDO MAGALLON 1/15/2019 1/16/2019 1/15/2019 COMPLETE 1ST FIRE (2 WK)EDGAR GONZALEZ 1/15/2019 1/29/2019 1/30/2019 APPROVED- CONDITIONS SEE CONDITIONS LETTER. Printed: Wednesday, January 25, 2023 3:37:05 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2019-0002 Office of the Fire Marshal City of La Quinta 78-495 Calle Tampico, La Quinta CA 92253 • Phone (760)777-7000 •Direct (760)777-7074 1/30/2019 Miranda Easton Alarmco Security Systems Inc. 451 Kansas St. Redlands, CA 92373 Re: Fire Alarm System Plan Review – Stater Bros. FA2019-0002 78-630 Highway 111 La Quinta, CA 92253 The alarm plans you submitted for the above referenced project have been reviewed by the Riverside County Fire Department and are approved with the following conditions: 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Function Test / Start 24-hour Battery - The alarm installer shall provide all needed testing equipment to complete the final alarm inspection. All fire alarm notification and initiating appliances shall be tested in accordance with NFPA 72. c) 5/15-Minute Ring-out / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 5. A zone map indicating location of all initiating devices shall be installed at an approved location. 6. All equipment keys shall be provided for placement in building’s KNOX box systems for Fire Department access. 7. All j-boxes and electric boxes serving fire alarm system shall be red in color or labeled. 8. Compartment/room containing fire alarm equipment that is capable of system operation shall be labeled "FACP" on exterior side. 9. All electrical breaker circuit switches controlling fire alarm power source shall be locked in the ON position for the life of the system by an approved lock-out assembly. Office of the Fire Marshal City of La Quinta 78-495 Calle Tampico, La Quinta CA 92253 • Phone (760)777-7000 •Direct (760)777-7074 10. All signals witnesses at function testing shall be verified before final approval is granted. The Fire Department approved plans, job card and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)863-8886. SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is subject to field inspection. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Edgar Gonzalez Fire Safety Specialist