Loading...
FA2019-0005ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT DESERT ALARM INC 73168 HWY 111 #204 PALM DESERT CA 92260 MANNY@DESERTALAR M.COM CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE AARON HICKSON 4/15/2019 4/15/2019 INFORMED CONTRACTOR OF CONDITIONS AND AS BUILTS NEEDED BEFORE FINAL PLAN CHECK PICKED UP AARON HICKSON 4/1/2019 4/1/2019 MANUEL PUGA PICKED UP CORRECTIONS PUBLIC COUNTER VISIT AARON HICKSON 4/10/2019 4/10/2019 ADDED CONTRACTORS EMAIL AND DID A TEST TO MAKE SURE HE WAS GETTING UPDATES RESUBMITTAL STEPHANIE SWANSTROM 4/9/2019 4/9/2019 ROUTED TO FIRE CONDITIONS Description: SPECTRUM / FIRE ALARM FOR TI BCOM2018-0047 Type: FIRE ALARM Subtype: COMMERCIAL - FIRE ALARM SYSTEM Status: FINALED Applied: 3/7/2019 JLIM Parcel No: 600440006 Site Address: 79785 HIGHWAY 111 STE 103 LA QUINTA,CA 92253 Approved: 4/15/2019 EGO Subdivision: PM 036269 Block: Lot: 6 Issued: 4/15/2019 AHI Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 7/15/2021 KHET Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Wednesday, January 18, 2023 3:03:24 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2019-0005 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL CONTRACTOR DESERT ALARM INC 73168 HWY 111 #204 PALM DESERT CA 92260 MANNY@DESERTALAR M.COM OWNER P6K PORTFOLIO KDP 2301 ROSECRANS STE 2110 EL SEGUNDO CA 92253 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH-WIRE INSPECTION EGO 4/16/2019 5/10/2019 APPROVED FUNCTION TEST EGO 4/16/2019 5/10/2019 APPROVED ROUGH-WIRE INSPECTION EGO 4/17/2019 5/10/2019 APPROVED FUNCTION TEST EGO 4/17/2019 5/10/2019 APPROVED FIRE FINAL**EGO 4/18/2019 7/15/2021 APPROVED PER CALENDAR NOTES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE ALARM SYSTEMS 101-0000-42421 0 $480.00 $480.00 3/7/19 MR686 33918 CHECK DESERT ALARM INC JLIM FIRE ALARM SYSTEMS PC 101-0000-42420 0 $560.00 $560.00 3/7/19 MR686 33918 CHECK DESERT ALARM INC JLIM Total Paid for FIRE FEES: $1,040.00 $1,040.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 3/7/19 MR686 33918 CHECK DESERT ALARM INC JLIM Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 3/7/19 MR686 33918 CHECK DESERT ALARM INC JLIM Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$1,055.00 $1,055.00 Printed: Wednesday, January 18, 2023 3:03:24 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2019-0005 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/26/2019 EDGAR GONZALEZ FA2019-0005 - SPECTRUM - 79-785 HWY 111 - FIRE ALARM (CORRECTIONS).docx FA2019-0005 - SPECTRUM - 79-785 HWY 111 - FIRE ALARM (CORRECTIONS).docx 1 DOC 4/15/2019 EDGAR GONZALEZ FA2019-0005 - SPECTRUM - 79-785 HWY 111 103 - FIRE ALARM (COA).docx FA2019-0005 - SPECTRUM - 79-785 HWY 111 103 - FIRE ALARM (COA).docx 1 BOND INFORMATION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) JACK LIMA 3/7/2019 3/7/2019 3/7/2019 1ST FIRE (2 WK)EDGAR GONZALEZ 3/7/2019 3/21/2019 3/26/2019 REVISIONS REQUIRED SEE CORRECTIONS LETTER. 2ND FIRE (2 WK)EDGAR GONZALEZ 4/9/2019 4/23/2019 4/15/2019 APPROVED- CONDITIONS SEE CONDITIONS LETTER. AS BUILTS DUE BY FINAL. PARENT PROJECTS Printed: Wednesday, January 18, 2023 3:03:24 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2019-0005 Office of the Fire Marshal City of La Quinta 78-495 Calle Tampico, La Quinta CA 92253 • Phone (760)777-7000 •Direct (760)777-7074 3/25/2019 Manny Puga Desert Alarm 73-168 Hwy 111 Suite 104 Palm Desert, CA Re: Spectrum FA2019-0005 79-785 Highway 111 La Quinta, CA 92253 The Fire Alarm plans you submitted for the above referenced project have been reviewed by the Riverside County Fire Department and are require revisions. Please review the corrections below and re-submit your plans providing a response/clarifying/correcting the listed items: 1.) The structure does indeed have an existing fire sprinkler system. Please correct on plan. 2.) The structure already contains an existing fire alarm control panel. That existing panel may either be upgraded to meet all tenant improvement needs or will have to be tied into existing panel by a relay module or power supply unit for new notification appliance circuits. 3.) NAC wiring shall be properly accounted for on voltage drop calculations. Shows 14 AWG while 16 AGW is noted on floor plan and other portion of plan. Please correct or clarify. 4.) Provide ceiling heights on floor plan. All questions regarding the meaning of these corrections should be referred to the Office of the Fire Marshal staff at (760)777-7074. Edgar Gonzalez Fire Safety Specialist Office of the Fire Marshal City of La Quinta 78-495 Calle Tampico, La Quinta CA 92253 • Phone (760)777-7000 •Direct (760)777-7074 4/15/2019 Manny Puga Desert Alarm Inc. 73-168 Hwy 111 #204 Palm Desert, CA 92253 Re: Fire Alarm System Plan Review – Spectrum FA2019-0005 79-785 Hwy 111 - 103 La Quinta, CA 92253 The alarm plans you submitted for the above referenced project have been reviewed by the Riverside County Fire Department and are approved with the following conditions: 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Function Test / Start 24-hour Battery - The alarm installer shall provide all needed testing equipment to complete the final alarm inspection. All fire alarm notification and initiating appliances shall be tested in accordance with NFPA 72. c) 5-Minute Ring-out / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 5. A zone map indicating location of all initiating devices shall be installed at an approved location. 6. All equipment keys shall be provided for placement in building’s KNOX box systems for Fire Department access. 7. All j-boxes and electric boxes serving fire alarm system shall be red in color or labeled. 8. Compartment/room containing fire alarm equipment that is capable of system operation shall be labeled "FACP" on exterior side. 9. All electrical breaker circuit switches controlling fire alarm power source shall be locked in the ON position for the life of the system by an approved lock-out assembly. 10. All signals witnesses at function testing shall be verified before final approval is granted. Office of the Fire Marshal City of La Quinta 78-495 Calle Tampico, La Quinta CA 92253 • Phone (760)777-7000 •Direct (760)777-7074 The Fire Department approved plans, job card and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)863-8886. SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is subject to field inspection. AS BUILT DRAWINGS SHALL BE SUBMITTED BEFORE FIANL IS GRANTED! All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Edgar Gonzalez Fire Safety Specialist