Loading...
FA2019-0009Description: PANEL UPGRADE AND CODE UPGRADE Type: FIRE ALARM (WEB) Subtype: COMMERCIAL - Status: FINALED Applied: 8/5/2019 EPRS SPRINKLER MONITORING Approved: 9/3/2019 KHET Parcel No: 604521009 Site Address: 44025 JEFFERSON ST STE 101 LA QUINTA,CA 92253 Subdivision: Block: Lot: Issued: 9/6/2019 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 9/12/2019 crw Valuation: $2,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: r3 29 �+ 6 Applied to Approved Approved to Issued Issued w Finaled ADDITIONAL CHRONOLOGY CONDITIONS CONDITION DATE DATE DATE CONTACT STATUS REMARKS NOTES TYPE ADDED REQUIRED SATISFIED READY TO ISSUE ARMANDO 9/3/2019 9/10/2019 COMPLETE CONTRACTOR BUSINESS LICENSE IS NEEDED CHECKLIST MAGALLON BEFORE ISSUANCE CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT Apple J Inc 45-625 Citurs Ave Suite Indio CA 92201 (760)835-2643 applejplumbing@gmail C com BILL TO Apple J Plumbing, Inc 45-625 Citurs Ave Suite Indio CA 92201 (760)835-2643 applejplumbing@gmail C Icom CONTRACTOR ALARMAS BAJA 48909 CHARLTON PEAK COACHELLA CA 92236 (760)835-2643 STREET Printed: Tuesday, February 14, 2023 9:18:52 AM 1 of 4 WSYSiEMS FINANCIAL INFORMATION CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY Credit Card Fee 101-0000-43505 0 $7.47 $7.47 8/5/19 WEB3969 CREDIT Apple J Inc EPRS Total Paid for Credit Card Fee: $7.47 $7.47 FIRE SPRINKLER SYSTEMS SUPERVISION 101-0000-42421 0 $160.00 $160.00 8/5/19 WEB3969 CREDIT Apple J Inc EPRS AND ALARMS FIRE SPRINKLER SYSTEMS SUPERVISION 101-0000-42420 0 $240.00 $240.00 8/5/19 WEB3969 CREDIT Apple J Inc EPRS AND ALARMS PC Total Paid for FIRE FEES: $400.00 $400.00 RECORDS 101-0000-42416 0 $10.00 $10.00 8/5/19 WEB3969 CREDIT Apple J Inc EPRS MANAGEMENT FEE Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 8/5/19 WEB3969 CREDIT Apple J Inc EPRS ENHANCEMENT FEE Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE ROUGH -WIRE INSPECTION KHET 9/11/2019 9/11/2019 APPROVED FUNCTION TEST KHET 9/11/2019 9/11/2019 APPROVED 24 HR. BATTERY TEST KHET 9/12/2019 9/12/2019 1 APPROVED Printed: Tuesday, February 14, 2023 9:18:52 AM 2 of 4 WsYsrEMS FIRE FINAL" KHET 9/12/2019 9/12/2019 APPROVED RETURNED REVIEWS STATUS REMARKS REVIEW TYPE REVIEWER SENT DATE DUE DATE NOTES DATE AFTER REVIEWING CONTRACTOR INFORMATION WE NOTICED THAT THE CONTRACTOR HAS A PLUMBING LICENSE ONLY. IN ORDER TO APPLY FOR THIS PERMIT A C-10 CONTRACTOR NEEDS TO BE LISTED EITHER ON THE PLANS OR ON THE 1ST PERMIT TECH (1 PERMIT TECH 8/5/2019 8/6/2019 8/7/2019 INCOMPLETE PERMIT. ONCE PLANS ARE REVISED TO SHOW C- DAY) BUCKET 10 CONTRACTOR WHO WILL BE DOING THE WORK FOR A FIRE ALARM WE CAN SET THE PLANS FOR REVIEW. PER KOHL. I CALLED APPLICANT AND LEFT THEM A VOICEMAIL YESTERDAY. 2ND PERMIT TECH — ARMANDO 8/20/2019 8/21/2019 8/21/2019 COMPLETE APPLICANT SUBMITTED 2ND REVIEW ETRAKIT (1 DAY) MAGALLON DOCUMENTS showing C-10 contractor. 2ND SUBMITTAL PLAN SET SHOW A C-10 1ST FIRE (2 WK) KOHL 8/20/2019 9/3/2019 9/3/2019 APPROVED- LICENSED CONTRACTOR ON PLANS. REVIEW HAS HETRICK CONDITIONS BEEN REINSTATED. (SEE 2ND REVIEW DOCUMENTS) BOND INFORMATION . Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/20/2019 ARMANDO MAGALLON 2ND SUBMITTAL- PLAN 2ND SUBMITTAL- PLAN 0 SET SET.pdf DOC 8/20/2019 ARMANDO MAGALLON 2ND SUBMITTAL - 2ND SUBMITTAL - 0 CUTSHEETS CUTSHEETS.pdf DOC 8/5/2019 EtrakitPublicReg 1ST SUBMITTAL - PLAN Jeff erson_Square-fa- 1 SET rev-O.pdf Printed: Tuesday, February 14, 2023 9:18:52 AM 3 of 4 WSYSiEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/5/2019 EtrakitPublicReg CUTSHEETS sbmt-booklet.pdf 1 DOC 8/5/2019 EtrakitPublicReg SITE PLAN shops-3_unit_A_FA.pdf 1 1ST SUBMITTAL - DOC 8/5/2019 EtrakitPublicReg OWNER OWNERLETTER.pdf 1 AUTHORIZATION FA2019-0009 - 2ND FA2019-0009 - 2ND DOC 9/3/2019 KOHL HETRICK SUBMITTAL - PLAN SET - SUBMITTAL - PLAN SET - 1 APPROVED.pdf APPROVED.pdf FA2019-0009 - JOB FA2019-0009 - JOB DOC 9/3/2019 KOHL HETRICK CARD AND LTR OF CARD AND LTR OF 1 COND.pdf COND.pdf Printed: Tuesday, February 14, 2023 9:18:52 AM 4 of 4 WSYSiEMS FIRE STOP METHODS SYSTEM No. W—L-1001 SYSTEM NO. WL1001 June 15, 2005 F RATINGS--1,2,3 AND 4 HR (SEE ITEMS 2 AND 3) T RATINGS--0,1,2,3 AND 4 HR (SEE ITEM 3) L Rating at Ambiei L Rating at 400 F SECTION A —A 1. Wall Assembly - The 1, 2, 3 or 4 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the Materials and in the manner described in the individual U300 or U400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include the following construction features; A. Studs - Wall framing may consist of either wood studs (max 2 hr fire rated assemblies) or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC with nom 2 by 4 in. (51 by 102 mm) lumber end plates and cross braces. Steel studs to be min 3-5/8 in. (92 mm) wide by 1-3/8 in. (35 mm) deep channels spaced max 24 in. (610 mm) OC. B. Gypsum Board* - Nom 1/2 or 5/8 in. (13 or 16 mm) thick, 4 ft. (122 cm) wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diar, of opening is 26 in. (660 mm). 2, Through Penetrant - One metallic pipe, conduit or tubing installed either concentrically or eccentrically within the firestop system. The annular space between pipe, conduit or tubing and periphery of opening shall be min of 0 in. (0 mm) (point contact) to max 2 in. (51 mm). Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used; A. Steel Pipe - Nom 24 in. (610 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 24 in. (610 mm) diam (or smaller) service weight (or heavier) cast iron soil pipe, nom 12 in. (305 mm) diam (or smaller) or Class 50 (or heavier) ductile iron pressure pipe. C. Conduit - Nom 6 in. (152 mm) diam (or smaller) steel conduit or nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing D. Copper Tubing - Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing E. Copper Pipe - Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. F. Through Penetrating Product* - Flexible Metal Piping - The following types of steel flexible metal gas piping may be used; 1. Nom 2 in. (51 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly, OMEGA FLEX INC 2, Nom 1 in, (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. TITEFLEX CORP A BUNDY CO 3. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. WARD MFG INC 3. Fill,Void or Cavity Material* - Caulk or Sealant - Min 5/8. 1-1/4,1-7/8 and 2-1/2 in. (16, 32, 48 and 64 mm) thickness of caulk for 1, 2, 3 and 4 hr rated assemblies, respectively, applied within annulus, flush with both surfaces of wall. Min 1/4 in. (6 mm) diam bead of caulk applied to gypsum board/penetrant interface at point contact location on both sides of wall. The hourly F Rating of the firestop system is dependent upon the hourly fire rating of the wall assembly in which it is installed, as shown in the following table. The hourly T Rating of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assembly in which it is installed, as tabulated below; Max Pipe or Conduit Dian in. (mm) F Rating Hr T Rating Hr 1 (25) 1 or 2 0+, 1 or 2 1 (25) 3 or 4 3 or 4 4 (102) 1 or 2 0 6 (152) 3 or 4 0 12 (305) 1 or 2 0 FIRE STOP METHODS SYSTEM No. F—A-1057 System No. F-A-1057 August 15, 2003 F Rating-21-Ir T Rating-21-Ir L Rating at Ambient-2CFM/sq ft L Rating at 4000 F-Less than 1 CFM/sq ft +When copper pipe is used, T Rating is 0 hr, 3M COMPANY - CP 25WB+ caulk or FB-3000 WT sealant, )(Bearing the UL Classification Marking Section A -A 1. Floor Assembly -Min 4-1/2 in. (114mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Max diam of opening 12-3/4 in. (324mm). 2. Through Penetrant -One metallic pipe or tubing installed concentrically or eccentrically within opening. Annular space between penetrant and periphery of opening shall be min of 0 in. (point contact) to max. 2 in. (omm to max 51 mm). Penetrant to be rigidly supported on both side of floor assembly. The following types and sizes of penetrants may be used: A. Steel Pipe-Nom 10 in. (254mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe-Nom 10 in. (254mm) diam (or smaller) cast or ductile iron pipe. C. Copper Tubing-Nom 4 in. (102mm) diam (or smaller) Type L (or heavier) copper tubing. D. Copper Pipe-Nom 4 in. (102mm) diam (or smaller) Regular (or heavier) copper pipe. 3. Firestop System -The details of the firestop system shall be as follows: A. Packing Material -Min 1 in. (25mm) thickness of min 4 pcf (64kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor to accommodate the required thickness of fill material. B. Fill, Void, or Cavity Materials* -Caulk or Putty -Min 1 in. (25mm) thickness of caulk or putty applied within the annulus, flush with top surface of floor. 3M COMPANY-CP25WB+ caulk or MP+ Stix putty. C. Duct Wrap Material*-Nom 2 in. (51 mm) thick duct wrap tightly wrapped around penetrant to extend 36 in. (914mm) above floor. An additional layer of nom 2 in. (51 mm) thick duct wrap tightly wrapped around the first layer of duct wrap to extend 12 in. (305mm) above floor. All longitudinal seams of both layers of duct wrap are sealed with foil tape. 3M COMPANY -Fire Barrier Duct Wrap 20A *Bearing the UL Classification Marking DRAWING INDEX FA-1.0 NOTES, CODES AND DETAILS FA-2.0 FLOOR PLANS AND RISER DIAGRAM AND CALCULATIONS FA-3.0 FIRE ALARM DETAILS FLOOR SEPARATION MIN 4 " (UNDERSIDE OF FLOOR ABOVE) TO NEXT DEVICE `----------------- - ---- - ----' TO NEXT DEVICE BACK -BOX NORN FLEX MAX 12z M- " g FINISHED CEILING �; HORN -STROBE lN 4" OR STROBE i MIN 36" ii BACK -BOX ;; BACK -BOX FINISHED CEILING II II FAlR-REGISTER ii LENS` ii r FIRE ALARM GENERAL NOTES: 1. THE FIRE ALARM SYSTEM, ITS INSTALLATION AND WIRING METHODS SHALL CONFORM TO ALL APPLICABLE SECTIONS OF THE CODES AND STANDARDS AS LISTED IN " BUILDING CODES & STANDARDS" ON THIS SHEET. 2. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AT ALL TIMES. ANY DEVIATIONS FROM THE APPROVED PLANS SHALL BE APPROVED BY THE AHJ. 3. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE CODE OR RECOGNIZED STANDARDS SHALL BE BROUGHT TO THE ATTENTION OF THE AHJ. 4, INPUT POWER (120VAC, 60Hz) FOR FIRE ALARM CONTROLS SHALL HAVE A RED MARKING, SHALL BE A DEDICATED LOCKING BREAKER PROPERLY LABELED "FIRE ALARM CIRCUIT CONTROL" AND SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL PANEL. 5. THE LOCATION OF THE FIRE ALARM CONTROL PANEL AND THE ANNUNCIATOR PANEL, IF APPLICABLE, SHALL BE APPROVED BY THE AUTHORITY -HAVING -JURISDICTION (AHJ). 6. TERMINAL CABINETS AND JUNCTION BOXES SHALL BE CLEARLY MARKED THAT THEY ARE PART OF THE FIRE ALARM SYSTEM. THE FIRE ALARM CONTROL PANEL (FACP) SHALL NOT BE USED AS A TERMINAL CABINET. 7. ALL FIELD WIRING ENTERING THE FACP MUST ENTER THE TOP OR BOTTOM -RIGHT OF THE PANEL. 8, N/A 9. ALL FIRE ALARM SYSTEM WIRING MUST TEST FREE OF OPENS SHORTS AND GROUNDS. WIRES SHALL NOT BE LOOPED THROUGH THE DEVICES, BUT CUT FOR "IN -AND -OUT". 10. IF CONDUIT IS USED, ALL CONDUIT SHALL BE MINIMUM 4" DIAMETER. CONTRACTOR TO INCREASE SIZE TO ACCOMMODATE FIELD CONDITIONS (NUMBER OF BENDS, J-BOXES, ETC). CONDUIT AND JUNCTION/BACK BOXES ARE NOT TO BE USED FOR UNRELATED WIRING. 11. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT AS LOW VOLTAGE WIRING. 12. THESE DRAWINGS ARE DIAGRAMMATIC. THEY SHOW DEVICE LOCATION, NUMBER OF CONDUCTORS, WIRE TYPE, CIRCUITING AND ROUTING. CONTRACTOR SHALL ROUTE CONDUIT AS FIELD CONDITIONS APPLY. THE FIRE ALARM EQUIPMENT LIST INDICATES THE MINIMUM -SIZED BACKBOXES TO WHICH SPECIFIC DEVICES ARE MOUNTED. THE INSTALLING CONTRACTOR SHALL ENSURE COMPLIANCE WITH GENERAL NOTE 1 ABOVE. 13. SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEANUP OF ALL TRADES IS COMPLETE AND FINAL. 14. CEILING SMOKE DETECTORS TO BE MOUNTED NO CLOSER THAN T-0" TO AN AIR SUPPLY DIFFUSER OR A RETURN AIR OPENING. 15. IF THE FIRE ALARM SYSTEM DOES NOT PROVIDE FULL AREA SMOKE DETECTOR COVERAGE, SMOKE DETECTORS TO BE INSTALLED WITHIN 5 FEET (1524mm) OF FIRE/SMOKE DAMPERS MOUNTED IN CEILINGS OR WALLS. 16. SUBSTITUTIONS FOR THE FIRE -STOP METHODS INDICATED ON THESE DRAWINGS ARE PERMISSIBLE WHEN APPROVED BY THE AHJ. 17. ALL DEVICES OF THE FIRE ALARM SYSTEM SHALL BE APPROVED AND LISTED BY THE CALIFORNIA STATE FIRE MARSHAL. 18. A MINIMUM OF 48 HOURS NOTICE SHALL BE REQUIRED PRIOR TO ANY INSPECTION AND/OR TEST. 19. UPON COMPLETION OF THE INSTALLATION OF THE FIRE ALARM SYSTEM, A SATISFACTORY TEST OF THE ENTIRE SYSTEM SHALL BE MADE IN THE PRESENCE OF THE AHJ. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE AHJ. CONTRACTOR SHALL PROVIDE ALL NECESSARY TEST EQUIPMENT. 20. DEVICES SHALL BE INSTALLED IN LOCATIONS ACCESSIBLE FOR SERVICE AND MAINTENANCE. ACCESS HATCH FOR DEVICES INSTALLED AT THE TOP OF ELEVATOR SHAFTS SHALL BE BY OTHERS. BUILDING CODES & STANDARDS FOLLOWING IS A LIST OF BUILDINGS CODES AND STANDARDS THAT ARE APPLICABLE TO THIS PROJECT: 2016 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24, C.C.R. 2016 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24, C.C.R. 2016 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24, C.C.R. 2016 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24, C.C.R. 2016 NFPA-72, AS AMENDED VICINITY MAP Arnela ar Parkway feplanOC s Fred Waring Dr ii ABACK BOX j SMOKE DETECTOR WITH BASE-1�� CO 4 CEILING -MOUNTED II a SMOKE DETECTOR WITH BASE II o Q WALL -MOUNTED 0 m Q a Qc g - z� - PULL STATION BACK —BOX g I � o TO TOP OF HANDLE — 48" °ocY In ­-1 /2 a Shade Builders 4 WALL SURFACE WALL SURFACE FINISHED FLOOR FFINISHED FL 0 R } FIRE ALARM DEVICES - MOUNTING HEIGHT NO IL S: 1. SEE EQUIPMENT LIST AND INSTALLATION MANUAL FOR MINIMUM BACK -BOX SIZES 2. IF CEILING HEIGHT IS TOO LOW, INSTALL STROBE OR HORN/STROBES WITHIN 6 IN. OF CEILING. J. FOR HORNS, USE EITHER ONE OF THE MOUNTING HEIGHTS INDICATED. Morning Gldy Lt SCOPE OF WORK 'red War,-. PROJECT NOTES: 1) Remote Monitoring Center - National Monitoring Center 25J41 Commerce Dr. Lake Forest, CA 926JO Phone: 800-662-1711 UL Listing Number- 257057-001 2) The AHU for unit A is equipped with a 120V AC duct smoke detector. Provided by the mechanical contractor. Monitored by the Fire Alarm System. J) There are no firelsmoke dampers. BUILDING INFO OCCUPANCY GROUP: M TYPE OF CONSTRUCTION: TYPE V-N FIRE SPRINKLERS: YES STORIES: 1 BUILDING AREA: 9080 SQFT SCOPE -OF -WORK AREA: 1150 SQFT APN: 604-521-005 FIRE ALARM EQUIPMENT LIST SYMBOL QTY. MANUFACTURER MODEL NO. DESCRIPTION CSFM FACP 1 FIRE-LITE MS-905OUD FIRE ALARM CONTROL PANEL (FACP) - EXISTING 7167-0075:0210 ❑F 2 FIRE-LITE BG-12LX MANUAL PULL STATION 7150-0075:0184 ® 1 1 FIRE-LITE SystemSensor SD365 B300-6 SMOKE DETECTOR HEAD SMOKE DETECTOR BASE 7272-0075:0502 7300-1653:0109 4 FIRE-LITE MMF-301 ADDRESSABLE INPUT MODULE (MONITOR MODULE), MINIATURE 7300-0075:0185 1 SystemSensor PC2RL HORN -STROBE, MULTI-cd, CEILING, RED 7135-1653:0503 2 SystemSensor SCRL STROBE, MULTI-cd, CEILING, RED 7125-1653:0504 O - BY OTHERS BY OTHERS DUCT SMOKE DETECTOR - ooc 1 Mier Products, Inc BW-DocBox FIRE ALARM DOCUMENT CABINET; UL-LISTED (E478235) NOT APPLICABLE wF 1 BY OTHERS BY OTHERS WATER -FLOW SWITCH - osv 1 BY OTHERS BY OTHERS OS&Y Ks 1 BY OTHERS BY OTHERS KNOX-BOX - Superv. FACP Annunciation station FNotific. System Outputs l o a ° c° o) a a c o Co 0 OC 6° .f6 � ice' mac° \ O \O JQ O CC r7 C ° C CO r0 C 0 A� \ , ° \Q ° \Q FF t 6 t \Q 0 0 \0 O q) ° 0 6 a o o �° JQ �c U OJ 0 OJ 0 OJ CO ,0 "�O '�0 "�O '�0 "�0 Cc Cc 'ti0 10 xJ0 xJ0 XJO xJ0 XJO xJO CO CO CO xJO �JO '41 U U Sequence of Operations System Inputs A B C D E F G H I J K L M N 0 P Q R 1 Manual fire alarm boxes X X X X X 2 Smoke det. AND/OR Heat det. X X X X X 3 Duct Smoke Detector X X X X X 4 Fire sprinkler waterflow X X X X X 5 Fire sprinkler control valve tamper X X X 6 Fire alarm AC power failure X X X 7 Fire alarm system low battery X X X 8 Open circuit X X X 9 Ground fault X X X 10 NAC short X X X 11 Cellular Communicator TROUBLE X X X 12 KNOX—BOX X X X SCOPE OF WORK Furnish and install a manual and automatic Fire Alarm System in AN EXISTING building. The system will be monitored by a UL—listed Central Station via cellular communicator. See Project Notes for name, address and UL certificate. APPROVED Riverside County Fire Department La Quinta Office of the Fire Marshal B oiN.i�ellY cigned EY KOFI Hetrick y: _"n CU toe,.i Off fth._Ri�em I,CN=K.hi Kohl Hetrick Le meat95 pintai�a cf ��ertre253 CN=Kahl NeVlck Location: ]8495 Calle Tampico. La ouinta. 92253 Rceson: have Z"77e thla dowmenl7.1 cou ntyfi re 09/03/2019 2:02:28 PM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. FA2019-0009 4 lkjw Jefferson Squ MonliCOL• toffee House Park soul al Mexico 4 Juice Bat Heritage Palms Golf Club FIRE ALARM WIRE LEGEND (POWER LIMITED) WIRE MFG.: West Penn AWG TYPE DESCRIPTION CONDUIT FPLR FPLP (Plenum) In,iapanikenre W.ry � � y L #18 2-cond, STP SLC - D975 D60975 ^°°i=�•V #14 2-cond VISUAL/STROBE (NAC) THHN - - Z #14 2-cond ZONE CIRCUIT (IDC) THHN - - acderafonca o 3 _ CONDUIT SIZE PERMISSIBLE AREA * CONDUIT SIZE PERMISSIBLE AREA 1/2" 0.12 SQ. INCH 1-1/4" 0.60 SQ. INCH WIillern sl�„e way D 3/4" 0.21 SQ. INCH 1-1/2" 0.82 SQ. INCH 1" 0.34 SQ. INCH 2" 1.34 SQ. INCH * PERMISSIBLE AREA TO BE OCCUPIED BASED ON NEC STANDARD OF 40% FILL. SIZE of CONDUIT MIN J 4 TO ACCOMMODATE THE SUM of AREAS OF ALL THE CABLES INSTALLED IN THE SAME CONDUIT. 1. USE CONDUCTORS SUITABLE FOR THE ENVIRONMENT. STRANDED WIRE MAY BE USED IF APPROVED BY AHJ. 2. EQUIVALENT WIRES (GAUGE, CLASSIFICATION, ETC.) BY OTHER MANUFACTURERS MAY BE USED. 3. UTP: UNSHIELDED TWISTED PAIR. STP: SHIELDED TWISTED PAIR. CO CO CO 00 N I- -,e N ti N M 00 Q a_ U � M Q Iz I O _ Q ``uJ vJ (n J N Z Q W Ly C)U U J o Q Q CD �O w Q ­t U F.- U NO. DATE REVISION DESCRIPTION z 05.02.19 PLAN REVIEW CORRECTIONS Q z i Cf`n7 V 0 J m L LU lVi/ �^^11 W aILL Z co N L0 Lu Q' W Cq rn O l5— V) Q O U a� 2 cr LL1 LL c () Q :2o z w .� U 0 w Q 0 3:M Lu m O -) U mOf O LL PROJECT NUMBER: PROJECT ENGINEER/DESIGNER: MICHAEL LUPSAIU DRAWN BY: DATE 1st ISSUED: MML 08-05-2019 SCALE: NOT TO SCALE SHEET TITLE: FIRE ALARM NOTES, CODES, SCHEDULES & SHEET INDEX SHEET NUMBER: FA-1.0 Iq FIRE ALARM EQUIPMENT LIST SYMBOL QTY. MANUFACTURER MODEL NO. DESCRIPTION CSFM FRCP 1 FIRE—LITE MS-9050UD FIRE ALARM CONTROL PANEL (FACP) — EXISTING 7167-0075:0210 ❑F 2 FIRE—LITE BG-12LX MANUAL PULL STATION 7150-0075:0184 ® 1 1 FIRE—LITE SystemSensor SD365 B300-6 SMOKE DETECTOR HEAD SMOKE DETECTOR BASE 7272-0075:0502 7300-1653:0109 4 FIRE—LITE MMF-301 ADDRESSABLE INPUT MODULE (MONITOR MODULE), MINIATURE 7300-0075:0185 1 SystemSensor PC2RL HORN —STROBE, MULTI—cd, CEILING, RED 7135-1653:0503 )( 2 SystemSensor SCRL STROBE, MULTI—cd, CEILING, RED 7125-1653:0504 O BY OTHERS BY OTHERS DUCT SMOKE DETECTOR — ooc 1 Mier Products, Inc BW—DocBox FIRE ALARM DOCUMENT CABINET; UL—LISTED (E478235) NOT APPLICABLE ❑ 1 BY OTHERS BY OTHERS WATER —FLOW SWITCH — osY 1 BY OTHERS BY OTHERS OS&Y KB 1 BY OTHERS BY OTHERS KNOX—BOX — j W 15 75 15 V- V1 V1 V1 (E) WIRES TO PHONE PHONE LINES TO 120V. AC POWER (DEDICATED CIRCUIT) RISER DIAGRAM SCALE.- NONE L I FACP I (E) FACP w/ 2 (E) PHONE JACKS VERIFY EXACT LOCATION SCOPE OF WORK: BUILDING 3, UNIT A T PARK LAND ADJACEI` RECREATIONAL � CEKM .c � � a (� LOADING 18 ry y POKM 20 OF s ( , i G ,a aw MAJOR °-- FUTURE . FRESHPC am RETAIlI:.. &EASY 13 PS Ncrr TD S C PIS 2 1 a928 SIP � ® 7,000 Sir EXCEED 3- TO E s + � tltl 7 DEVELOPED RYOTHERS 7 o s ADJACMt @Q l6 o d) 1A GOT4TRIR ® 11 i� ` LM 1� i 4 ix a: � J �• ffi ,8� , d 18 n r- ka..L m 12 2V PW 7& 14 . QPS'I e „ DRUG ' a 13,013 SF gg ToEEDEVELOPED 4 ® n rlv7 EW pT RM n RAM ORE 14 .a PAD A 1 a 4_5#00'SFGAS— ' ,8 NIMMAREA i 72 4 I ISOSF(.42AC) e POVM 07 12 , 9 DECELAMTMLAM —: - - T. CM nRONUMMT C �SITE PLAN- an SCALE.- NONE 0 e. EOL 0 if 1 ..•r.«... ..... r �.n� .rn ..r.,. rr ww TO FACP L i r 75 lift EOL Vl I I z EOL KB µ�r (E) KNOX- BOX. 64 IVERIFY EXACT LOCATION $ I rt q- i 7� i61—:1_F_ I �I r r� - .. r I I FLOOR PLAN- n d SCALE.- 118- = 1'_0- 77 1 NOT IN SCOPE , NOTES KEYNOTES 1. ALL CEILINGS ARE AT 11 FT. A.F.F., UNLESS TO 120V AC, DEDICATED POWER CIRCUIT. OTHERWISE NOTED. LOCK AND TAG CIRCUIT BREAKER PER NFPA-72 REQUIREMENTS. TO 120V AC DUCT SMOKE DETECTOR FOR MONITORING PURPOSES. FIELD -VERIFY EXACT LOCATION. DUCT SMOKE DETECTOR BY OTHERS. APPROVED Riverside County Fire Department La Quinta Office of the Fire Marshal B d e9 a �e,� oaamaa oN; o=us9 E=� lm rmx@u.aoa.y o=Ru,a oppmv Fo-a Y� Kohl Hetrick .,7�95-,T-p—La„naF��MasnaL��-Kon�Ra,,ak Location'. )8495 Calie Tampico, La QUln�d. 92253 countyfire 09/03/2019 2:02:40 PM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. 11 i I � � (E) FACP w/ 2 (E) PHONE JACK VERIFY EXACT LOCATION 1 FACP 1 L S ELEC RAC TO FACP 1 1 L v IETML A '�'f�. IIliF1R t)f9a 5'F ITPL 8 AMON 4ft10W Im raT+M Me 2: RETAMD.IL C. 1%x sr jav X5F 7rt37sE, Oft tIK !;F RETAIL D wa A%r :" * VIM m W3F &� BY TE.NW — r RETAIL �� =ww lak IN! IF i lam. FA2019-0009 3 z SCOPE OF WORK: BUILDING 3, UNIT A 140 V1 TO FACP ' :n '6 TO FACP I+ L � 1. V175 V F a? if f� �7 4 RTY U BOILER Rom, WATER HVkTFR W � ��� 1,t 5 4. A I _. __ II 04 04 ti ao rn 00 U TM_ rn m ° Q cw J O Z Q LL] w U_ U 1-0 J o Q 0 JoO w Q '�t U F.- U NO. DATE REVISION DESCRIPTION Al 05.02.19 PLAN REVIEW CORRECTIONS I— Z D 1 M 0 m o W c Q � LL co cu Z w w c� Lo U) N � o } ° U Q LU LL] LL o a Q LL U LU Q z W CY o LU co O c,3 (n m 0� O LL PROJECT NUMBER: PROJECT ENGINEER/DESIGNER: MICHAEL LUPSAIU DRAWN BY: DATE 1st ISSUED: MML 08-05-2019 SCALE: AS NOTED SHEET TITLE: FLOOR PLAN RISER CALCULATIONS SHEET NUMBER: FA- 2.0 I l 777 - II II I♦ � !�I. v^� � 20 i� ;fn i" ^=i %�\ (�' ■. - �II NG� � ■ � •. �a�� ■ � � :� a r__re o, Ih+li \�% iif_al � � � . I �� . .vim,, Iill�ll II�II FRCP NOTE: FACP AND PHONE LINE CONNECTIONS ARE EXISTING TO PHONE LINE 2 TO PHONE LINE 1 TO ADDRESSABLE INITIATING DEVICES STROBES V1 WIRING DIAGRAM - TYPICAL FIRE ALARM PERIPHERALS - TYPICAL FACP Battery Calculation Secondary Power Source Requirements Device Standby Current (amps) Secondary Alarm Current (amps) Qty Current Draw Total Qty Current Draw Total Main Circuit Board 1 1 jxj 0.120000 1=1 0.120000 1 1 jxj 0.257000 1=1 0,257000 Addressable Devices SD365 1 x 0.000300 = 0.000300 MMF-301 4 x 0.000375 = 0.001500 BG-12LX 2 x 1 0.000375 = 0.000750 Maximum alarm draw for all Addressable devices---------------> 0.20000 Output Circuits NACIOutput #1 0,000000 = 0,295000 = 0,295000 NACIOutput #2 0,000000 = 0,000000 = FCPS (remote Sync) 0 x 0.o00000 = a x 0.021700 = Total Standby Load 0.122550 Total Alarm Load 0.752000 Calculation in Total Sheet Required Standby Time in Hours 24 Hours Total Standby Current 0.1226 Amps x 24 1 = 1 2.941 A Required Alarm Time in Minutes 5 Minutes 11111 Total Alarm Load 0.7520 Amps x F 0.084 1 = 0.063 A H Total Current Load 3.004 AH Multiply by the Derating Factor 1.2 = x 1.20 Total Ampere Hours Required 3.61 A Batteries Provided*: BAT-1270 - 7AH Batteries " Two (2) batterry, each 12V @ 7Ah Voltage Drop Calculation CIRCUIT CKT CKT ON ON PANEL FLR.PLN. Hornistrobes V1 SPARE JV2 Formula for calculating Voltage Drop: Voltage( EL = Voltage@BG - (Total Current" 2 *Length* R) Votage @EL: at End of Line Voltage L7a BC, at Beginning of Circuit R-- Resistance / foot-ef-wire WIRE RESISTANCE/fact-of-wire 12GA = 0.00177 0,00200 14GA= 0.00282 0,00310 16GA = 0.00450 0-00500 Voltage at begining of cErcuit NOTES 1. Current draw shown is MAXIMUM (at lowest voltage of 16 V) CALCULATIONS APPROVED Riverside County Fire Department La Quinta Office of the Fire Marshal B DI91uIlY sl9netl by'O NeNck y . DN C=US E=koM1l M1eMck�fire ca goo O=Riversitle County Fire Kohl Hetrick L—timeIM95-LeD�ia,aD.e Q—,92253M1ai DN KOM1INe,tlk Location'. ]8496 Calle Tampico. La Quinta, 9 -r Contact Info: )60-]]]-IO)p s tlocumenl cou ntyfi re 09/03/2019 2:02:53 PM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. FA2019-0009 SCRL STROBES PG2RL HORN -STROBES LENGTH Wire Gauge Total Current [A] Voltage Drop 1%] Voltage at End of Line M A/V CEILING CEILING W.P. 15Cd 30Cd 75Cd 95Cd 110Cd 15cd 30Cd 75Cd 95Cd 110cd 0.041 0-063 -0111 -0134 0.000 0.071 0.090 0.143 0.165 0-000 OA76 1 1 1 1061 14 1 0.295 0.80!a 1 23.81 01 14 1 0.000 0.0% 1 24.00 TOTAL ClJRRENT 0.295 N 6' rn 00 U a)Q w m 0 J ti U) LU Q = LL] 2 U 1-0 _U J Q C) Q J O � O Lu Q ,1- U U NO. DATE REVISION DESCRIPTION Al 05.02.19 PLAN REVIEW CORRECTIONS Q z i CM J m L LU c Q � LL z O N 0 < o } Q0U LLI �) a_2 E IY LU ILL LU v C� (n J Lu Q o z Lu w O -) U7 O LL PROJECT NUMBER: PROJECT ENGINEER/DESIGNER: MICHAEL LUPSAIU DRAWN BY: DATE 1st ISSUED: M M L 08-05-2019 SCALE: NONE SHEET TITLE: FIRE ALARM CALCULATIONS AND DETAILS SHEET NUMBER: FA- 3.0 ADJACENT RESIDENTIAL PROFURTIES nerlyCL.1~ — i CENTER VAS^ METH F8 m LA DSC"ED R)ETENTIONAREA T M 180 SF [.42 AQ # w , I a I , , I , -- -- LOADING cAs- A w AC>JACr=W RECREATMAL PARK LAND 2 t Lf3AO81L: R�.'t'CjL .... MAL Ar�A c2NTM ODA.* MAJOR FUTURE RETAILMOTT• !i sss EXCiEED -•• • k SP IN i� DRUG bL: r * z CeVS ■ice Y OPED A F �. TOTAL SITE AREA: RETAIL SITE COVERAGE- 10,79 AC (470.080 SF) ti a.i 4% USE Sqq��IIARE F(�E1iAGE F"AP�CINC{ HATE REgg��IRED P11�IONG (f STALLS) pFlOd1 PARKWO (i STALLS) FUTURE MAJOR A 4Z500 5F 4.0/1,000 5F 170 FRESH do EASY 13,928 SF 4.0/1,400 SF 56 DRLiG 13,013 5F 410/1,000 SF 52 SLOPS 15,500 SF 4.O/1,006 SF 66 PADS 4,500 SF 4.0f 000 sr 1B `10TAL 9%441 Sr-1 362 362 FUEL EFFICIENT PARKING 5% of 362 = 19>�aoaaprovldsd OVERALL 97E PARKING RATfO = t4.0/1,000 SF l � I MINT ,%I t I IF; I SITE PLAN KEG' NOTES Ciy �E�rra�apR4§�Rk��W-8 z, �94'�na$p+s�eia�9 kH+E Dftwom 4 al7RtML vovAf Iruzop <Km *W Alp ppp IANF�GPf<,yA kpRiL'il • SF WiA9pYR'.VPMWW Y ' imrrr AFifRiLK MW HArVWPW "%MWMDOL Ar lulikG.AFP&P FAAM 9M JB0 GM sTv",nfxmslalAm 'a:Eunwf IQr3 pm "mmcF mwa:P am-e V�4samwmawaoNusiTrax;s m�fr We wm rnn corn aF Li3aeeAr a� � a- c pm r pmnm LWATWD �iAi4T::AT�CH.11AfAHS A iFRGS T&�t3.fik AT l4-e i lR'GhTF Wa M W A TW " AR r H1 fAFF}jA pMl C310 MlnM IGi G VV CWM F2w OE Dom 71]A-A77!�TOP A7A.7 fEl fr.03FT6m smM49iit0 U: YS6. YFE'oOArt� YU COCmdLSf SViH A).1KkFJ�7 dFfAL"t&Sk'E pEYp19 n,Wp '9 �1 ftiEET A� w�ix uxxx� rtc Mwm�s�WArreanu PM Ar+m TehmmaAu.��xx� f3]A BLBYffTI .F LN7OBTAMR APPRGVAL FF87{A CWIQ. k m1E$i 6 UE WmFrAps Na iials. hM" 1 DOSCHPUM ...: .•_ 32.19-07 &D.. SUaWFFAL proia JEFFERSON SQUARE La Q►uinta, CA REGENCY CENTERS 361 ac mive Park, Suite 100 l vine, Ca 02614 60891 CONSTRUCTION MONITORING $ • 'f4NT TkBEbLAAAI. ASPS CF trE PROS'r LLY1f{3 BY �ABQpCLIF z KTGYGROUF, > oa iP��Alf, #a1lALhAidW$#ICf11IS 8i: 095dt' A1i'RTi,� T '� 4= Lki1Z,L�i a i}Al'PFKJFi Ta ELFf 6piO1EfE bk IVdf FlL ALtreGi ry 8A890GA•{ffi Ai i.KAB!'TY11S'fCWf91Ai MlOLPOS PfUQH Tr] kr"z ssa+Mzta.r.:sOUrx 1'$Mlti ,f.,16 YZ 1 AHa' L SIFE �� Aw FEE4ED$r5l6 i8rr, 1949] 2964�'Jd�B PA7C CONSTRUCTION NOTES It"AII.'SrUDIC � Re ON&OFEW cor:(ifvomw n,M� iS P1�BBLe pm Prz TAei OF vimm A3. 4k 0 � CN THE Vo� mm ALA No*" vm ON-Y. $00IIH@ swap 70(:SW.L 6�.p,Y! Ld1GM i� D1: il-�HO(@CNlFAj. COMR0. PEIH BY-ri� aw. AfLY Alamo NJfi•Y ttk: �1 ONKWWVNaOkOi ASFn"TE POW VOk ."F71W aN OE hn aAvxA p,ssr>tia;�� dkeot LMAL DESCRIPTION prqhmt We Fhm p O*& mmmom' malani Damumb W pmjC# deIkIAUf�gI4 1�i�'II£ T011P�1 68p1[s!{whm i � �� BB"Fnm &a om mamm A88�tt Lmrw STAi� {.A7yg g,F�y, w w PFopa rr 16 ALSe a-m ON f W= OF apoEy ON E0 E H ocxx A RAGE 6 Op 4�8LR1EX, 6.00N ?'. $Chit wn4poFmIl MOPE PAIiTIC([/HI.Y A9 FIXlAIV9 LY7WMMNra AT 111E r101nNtilsr aP DO e9: r 2MTMMX0Na nix wmm §Fmfdw cp aa,,' m sm" wwo"m mm mlr Wbo, . OMW SWI6W 4 ' It! THE l" Peas OF S A4@ �FB <E wiirurz m AmIsm FIEF 9a ml CF TFE MM OF fEamm 21 safM 862@=19' NSBr EUroOE 6a kppS{H oo mrl<st tax Try HGF+nt k�W Farr, FAT Tq A P4ptl'., PEST §40.81 4 T qE a L NE of i $! pOtifii GP7AtlA'M@iF, p +E 73M FELF Tn Tna DF A TAh EW YAWShO s arm. MNOkW. %k�X-fhHJC6 NONfF#NE$SEiir NjoNs TEE AVC OF WO OMUM A L a, PLAN OOMN, M92F Cp 9A'k1aL,; A DstkoSaue' f sw =Im THE Rm ABiQw 4F R OZ&M A 8CU S% OOPt�ft Fib VO�AIJ3 L't74EA1A}. enq£ LA gt*ffT u aurrrAs ca Aft R W+snt 5 t fIW A• 00 L FIRE STOP METHODS SYSTEM No. W—L-1001 SYSTEM NO. WL1001 June 15, 2005 F RATINGS--1,2,3 AND 4 HR (SEE ITEMS 2 AND 3) T RATINGS--0,1,2,3 AND 4 HR (SEE ITEM 3) L Rating at Ambiei L Rating at 400 F SECTION A —A 1. Wall Assembly - The 1, 2, 3 or 4 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the Materials and in the manner described in the individual U300 or U400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include the following construction features; A. Studs - Wall framing may consist of either wood studs (max 2 hr fire rated assemblies) or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC with nom 2 by 4 in. (51 by 102 mm) lumber end plates and cross braces. Steel studs to be min 3-5/8 in. (92 mm) wide by 1-3/8 in. (35 mm) deep channels spaced max 24 in. (610 mm) OC. B. Gypsum Board* - Nom 1/2 or 5/8 in. (13 or 16 mm) thick, 4 ft. (122 cm) wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diar, of opening is 26 in. (660 mm). 2, Through Penetrant - One metallic pipe, conduit or tubing installed either concentrically or eccentrically within the firestop system. The annular space between pipe, conduit or tubing and periphery of opening shall be min of 0 in. (0 mm) (point contact) to max 2 in. (51 mm). Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used; A. Steel Pipe - Nom 24 in. (610 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 24 in. (610 mm) diam (or smaller) service weight (or heavier) cast iron soil pipe, nom 12 in. (305 mm) diam (or smaller) or Class 50 (or heavier) ductile iron pressure pipe. C. Conduit - Nom 6 in. (152 mm) diam (or smaller) steel conduit or nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing D. Copper Tubing - Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing E. Copper Pipe - Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. F. Through Penetrating Product* - Flexible Metal Piping - The following types of steel flexible metal gas piping may be used; 1. Nom 2 in. (51 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly, OMEGA FLEX INC 2, Nom 1 in, (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. TITEFLEX CORP A BUNDY CO 3. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. WARD MFG INC 3. Fill,Void or Cavity Material* - Caulk or Sealant - Min 5/8. 1-1/4,1-7/8 and 2-1/2 in. (16, 32, 48 and 64 mm) thickness of caulk for 1, 2, 3 and 4 hr rated assemblies, respectively, applied within annulus, flush with both surfaces of wall. Min 1/4 in. (6 mm) diam bead of caulk applied to gypsum board/penetrant interface at point contact location on both sides of wall. The hourly F Rating of the firestop system is dependent upon the hourly fire rating of the wall assembly in which it is installed, as shown in the following table. The hourly T Rating of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assembly in which it is installed, as tabulated below; Max Pipe or Conduit Dian in. (mm) F Rating Hr T Rating Hr 1 (25) 1 or 2 0+, 1 or 2 1 (25) 3 or 4 3 or 4 4 (102) 1 or 2 0 6 (152) 3 or 4 0 12 (305) 1 or 2 0 FIRE STOP METHODS SYSTEM No. F—A-1057 System No. F-A-1057 August 15, 2003 F Rating-21-Ir T Rating-21-Ir L Rating at Ambient-2CFM/sq ft L Rating at 4000 F-Less than 1 CFM/sq ft +When copper pipe is used, T Rating is 0 hr, 3M COMPANY - CP 25WB+ caulk or FB-3000 WT sealant, )(Bearing the UL Classification Marking Section A -A 1. Floor Assembly -Min 4-1/2 in. (114mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Max diam of opening 12-3/4 in. (324mm). 2. Through Penetrant -One metallic pipe or tubing installed concentrically or eccentrically within opening. Annular space between penetrant and periphery of opening shall be min of 0 in. (point contact) to max. 2 in. (omm to max 51 mm). Penetrant to be rigidly supported on both side of floor assembly. The following types and sizes of penetrants may be used: A. Steel Pipe-Nom 10 in. (254mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe-Nom 10 in. (254mm) diam (or smaller) cast or ductile iron pipe. C. Copper Tubing-Nom 4 in. (102mm) diam (or smaller) Type L (or heavier) copper tubing. D. Copper Pipe-Nom 4 in. (102mm) diam (or smaller) Regular (or heavier) copper pipe. 3. Firestop System -The details of the firestop system shall be as follows: A. Packing Material -Min 1 in. (25mm) thickness of min 4 pcf (64kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor to accommodate the required thickness of fill material. B. Fill, Void, or Cavity Materials* -Caulk or Putty -Min 1 in. (25mm) thickness of caulk or putty applied within the annulus, flush with top surface of floor. 3M COMPANY-CP25WB+ caulk or MP+ Stix putty. C. Duct Wrap Material*-Nom 2 in. (51 mm) thick duct wrap tightly wrapped around penetrant to extend 36 in. (914mm) above floor. An additional layer of nom 2 in. (51 mm) thick duct wrap tightly wrapped around the first layer of duct wrap to extend 12 in. (305mm) above floor. All longitudinal seams of both layers of duct wrap are sealed with foil tape. 3M COMPANY -Fire Barrier Duct Wrap 20A *Bearing the UL Classification Marking DRAWING INDEX FA-1.0 NOTES, CODES AND DETAILS FA-2.0 FLOOR PLANS AND RISER DIAGRAM AND CALCULATIONS FA-3.0 FIRE ALARM DETAILS FLOOR SEPARATION MIN 4 " (UNDERSIDE OF FLOOR ABOVE) TO NEXT DEVICE `----------------- - ---- - ----' TO NEXT DEVICE BACK -BOX NORN FLEX MAX 12z M- " g FINISHED CEILING �; HORN -STROBE lN 4" OR STROBE i MIN 36" ii BACK -BOX ;; BACK -BOX FINISHED CEILING II II FAlR-REGISTER ii LENS` ii r FIRE ALARM GENERAL NOTES: 1. THE FIRE ALARM SYSTEM, ITS INSTALLATION AND WIRING METHODS SHALL CONFORM TO ALL APPLICABLE SECTIONS OF THE CODES AND STANDARDS AS LISTED IN " BUILDING CODES & STANDARDS" ON THIS SHEET. 2. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AT ALL TIMES. ANY DEVIATIONS FROM THE APPROVED PLANS SHALL BE APPROVED BY THE AHJ. 3. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE CODE OR RECOGNIZED STANDARDS SHALL BE BROUGHT TO THE ATTENTION OF THE AHJ. 4, INPUT POWER (120VAC, 60Hz) FOR FIRE ALARM CONTROLS SHALL HAVE A RED MARKING, SHALL BE A DEDICATED LOCKING BREAKER PROPERLY LABELED "FIRE ALARM CIRCUIT CONTROL" AND SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL PANEL. 5. THE LOCATION OF THE FIRE ALARM CONTROL PANEL AND THE ANNUNCIATOR PANEL, IF APPLICABLE, SHALL BE APPROVED BY THE AUTHORITY -HAVING -JURISDICTION (AHJ). 6. TERMINAL CABINETS AND JUNCTION BOXES SHALL BE CLEARLY MARKED THAT THEY ARE PART OF THE FIRE ALARM SYSTEM. THE FIRE ALARM CONTROL PANEL (FACP) SHALL NOT BE USED AS A TERMINAL CABINET. 7. ALL FIELD WIRING ENTERING THE FACP MUST ENTER THE TOP OR BOTTOM -RIGHT OF THE PANEL. 8, N/A 9. ALL FIRE ALARM SYSTEM WIRING MUST TEST FREE OF OPENS SHORTS AND GROUNDS. WIRES SHALL NOT BE LOOPED THROUGH THE DEVICES, BUT CUT FOR "IN -AND -OUT". 10. IF CONDUIT IS USED, ALL CONDUIT SHALL BE MINIMUM 4" DIAMETER. CONTRACTOR TO INCREASE SIZE TO ACCOMMODATE FIELD CONDITIONS (NUMBER OF BENDS, J-BOXES, ETC). CONDUIT AND JUNCTION/BACK BOXES ARE NOT TO BE USED FOR UNRELATED WIRING. 11. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT AS LOW VOLTAGE WIRING. 12. THESE DRAWINGS ARE DIAGRAMMATIC. THEY SHOW DEVICE LOCATION, NUMBER OF CONDUCTORS, WIRE TYPE, CIRCUITING AND ROUTING. CONTRACTOR SHALL ROUTE CONDUIT AS FIELD CONDITIONS APPLY. THE FIRE ALARM EQUIPMENT LIST INDICATES THE MINIMUM -SIZED BACKBOXES TO WHICH SPECIFIC DEVICES ARE MOUNTED. THE INSTALLING CONTRACTOR SHALL ENSURE COMPLIANCE WITH GENERAL NOTE 1 ABOVE. 13. SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEANUP OF ALL TRADES IS COMPLETE AND FINAL. 14. CEILING SMOKE DETECTORS TO BE MOUNTED NO CLOSER THAN T-0" TO AN AIR SUPPLY DIFFUSER OR A RETURN AIR OPENING. 15. IF THE FIRE ALARM SYSTEM DOES NOT PROVIDE FULL AREA SMOKE DETECTOR COVERAGE, SMOKE DETECTORS TO BE INSTALLED WITHIN 5 FEET (1524mm) OF FIRE/SMOKE DAMPERS MOUNTED IN CEILINGS OR WALLS. 16. SUBSTITUTIONS FOR THE FIRE -STOP METHODS INDICATED ON THESE DRAWINGS ARE PERMISSIBLE WHEN APPROVED BY THE AHJ. 17. ALL DEVICES OF THE FIRE ALARM SYSTEM SHALL BE APPROVED AND LISTED BY THE CALIFORNIA STATE FIRE MARSHAL. 18. A MINIMUM OF 48 HOURS NOTICE SHALL BE REQUIRED PRIOR TO ANY INSPECTION AND/OR TEST. 19. UPON COMPLETION OF THE INSTALLATION OF THE FIRE ALARM SYSTEM, A SATISFACTORY TEST OF THE ENTIRE SYSTEM SHALL BE MADE IN THE PRESENCE OF THE AHJ. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE AHJ. CONTRACTOR SHALL PROVIDE ALL NECESSARY TEST EQUIPMENT. 20. DEVICES SHALL BE INSTALLED IN LOCATIONS ACCESSIBLE FOR SERVICE AND MAINTENANCE. ACCESS HATCH FOR DEVICES INSTALLED AT THE TOP OF ELEVATOR SHAFTS SHALL BE BY OTHERS. BUILDING CODES & STANDARDS FOLLOWING IS A LIST OF BUILDINGS CODES AND STANDARDS THAT ARE APPLICABLE TO THIS PROJECT: 2016 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24, C.C.R. 2016 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24, C.C.R. 2016 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24, C.C.R. 2016 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24, C.C.R. 2016 NFPA-72, AS AMENDED VICINITY MAP Arnela ar Parkway feplanOC s Fred Waring Dr ii ABACK BOX j SMOKE DETECTOR WITH BASE-1�� CO 4 CEILING -MOUNTED II a SMOKE DETECTOR WITH BASE II o Q WALL -MOUNTED 0 m Q a Qc g - z� - PULL STATION BACK —BOX g I � o TO TOP OF HANDLE — 48" °ocY In ­-1 /2 a Shade Builders 4 WALL SURFACE WALL SURFACE FINISHED FLOOR FFINISHED FL 0 R } FIRE ALARM DEVICES - MOUNTING HEIGHT NO IL S: 1. SEE EQUIPMENT LIST AND INSTALLATION MANUAL FOR MINIMUM BACK -BOX SIZES 2. IF CEILING HEIGHT IS TOO LOW, INSTALL STROBE OR HORN/STROBES WITHIN 6 IN. OF CEILING. J. FOR HORNS, USE EITHER ONE OF THE MOUNTING HEIGHTS INDICATED. Morning Gldy Lt SCOPE OF WORK 'red War,-. PROJECT NOTES: 1) Remote Monitoring Center - National Monitoring Center 25J41 Commerce Dr. Lake Forest, CA 926JO Phone: 800-662-1711 UL Listing Number- 257057-001 2) The AHU for unit A is equipped with a 120V AC duct smoke detector. Provided by the mechanical contractor. Monitored by the Fire Alarm System. J) There are no firelsmoke dampers. BUILDING INFO OCCUPANCY GROUP: M TYPE OF CONSTRUCTION: TYPE V-N FIRE SPRINKLERS: YES STORIES: 1 BUILDING AREA: 9080 SQFT SCOPE -OF -WORK AREA: 1150 SQFT APN: 604-521-005 FIRE ALARM EQUIPMENT LIST SYMBOL QTY. MANUFACTURER MODEL NO. DESCRIPTION CSFM FACP 1 FIRE-LITE MS-905OUD FIRE ALARM CONTROL PANEL (FACP) - EXISTING 7167-0075:0210 ❑F 2 FIRE-LITE BG-12LX MANUAL PULL STATION 7150-0075:0184 ® 1 1 FIRE-LITE SystemSensor SD365 B300-6 SMOKE DETECTOR HEAD SMOKE DETECTOR BASE 7272-0075:0502 7300-1653:0109 4 FIRE-LITE MMF-301 ADDRESSABLE INPUT MODULE (MONITOR MODULE), MINIATURE 7300-0075:0185 1 SystemSensor PC2RL HORN -STROBE, MULTI-cd, CEILING, RED 7135-1653:0503 2 SystemSensor SCRL STROBE, MULTI-cd, CEILING, RED 7125-1653:0504 O - BY OTHERS BY OTHERS DUCT SMOKE DETECTOR - ooc 1 Mier Products, Inc BW-DocBox FIRE ALARM DOCUMENT CABINET; UL-LISTED (E478235) NOT APPLICABLE wF 1 BY OTHERS BY OTHERS WATER -FLOW SWITCH - osv 1 BY OTHERS BY OTHERS OS&Y Ks 1 BY OTHERS BY OTHERS KNOX-BOX - Superv. FACP Annunciation station FNotific. System Outputs l o a ° c° o) a a c o Co 0 OC 6° .f6 � ice' mac° \ O \O JQ O CC r7 C ° C CO r0 C 0 A� \ , ° \Q ° \Q FF t 6 t \Q 0 0 \0 O q) ° 0 6 a o o �° JQ �c U OJ 0 OJ 0 OJ CO ,0 "�O '�0 "�O '�0 "�0 Cc Cc 'ti0 10 xJ0 xJ0 XJO xJ0 XJO xJO CO CO CO xJO �JO '41 U U Sequence of Operations System Inputs A B C D E F G H I J K L M N 0 P Q R 1 Manual fire alarm boxes X X X X X 2 Smoke det. AND/OR Heat det. X X X X X 3 Duct Smoke Detector X X X X X 4 Fire sprinkler waterflow X X X X X 5 Fire sprinkler control valve tamper X X X 6 Fire alarm AC power failure X X X 7 Fire alarm system low battery X X X 8 Open circuit X X X 9 Ground fault X X X 10 NAC short X X X 11 Cellular Communicator TROUBLE X X X 12 KNOX—BOX X X X SCOPE OF WORK Furnish and install a manual and automatic Fire Alarm System in AN EXISTING building. The system will be monitored by a UL—listed Central Station via cellular communicator. See Project Notes for name, address and UL certificate. APPROVED Riverside County Fire Department La Quinta Office of the Fire Marshal B oiN.i�ellY cigned EY KOFI Hetrick y: _"n CU toe,.i Off fth._Ri�em I,CN=K.hi Kohl Hetrick Le meat95 pintai�a cf ��ertre253 CN=Kahl NeVlck Location: ]8495 Calle Tampico. La ouinta. 92253 Rceson: have Z"77e thla dowmenl7.1 cou ntyfi re 09/03/2019 2:02:28 PM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. FA2019-0009 4 lkjw Jefferson Squ MonliCOL• toffee House Park soul al Mexico 4 Juice Bat Heritage Palms Golf Club FIRE ALARM WIRE LEGEND (POWER LIMITED) WIRE MFG.: West Penn AWG TYPE DESCRIPTION CONDUIT FPLR FPLP (Plenum) In,iapanikenre W.ry � � y L #18 2-cond, STP SLC - D975 D60975 ^°°i=�•V #14 2-cond VISUAL/STROBE (NAC) THHN - - Z #14 2-cond ZONE CIRCUIT (IDC) THHN - - acderafonca o 3 _ CONDUIT SIZE PERMISSIBLE AREA * CONDUIT SIZE PERMISSIBLE AREA 1/2" 0.12 SQ. INCH 1-1/4" 0.60 SQ. INCH WIillern sl�„e way D 3/4" 0.21 SQ. INCH 1-1/2" 0.82 SQ. INCH 1" 0.34 SQ. INCH 2" 1.34 SQ. INCH * PERMISSIBLE AREA TO BE OCCUPIED BASED ON NEC STANDARD OF 40% FILL. SIZE of CONDUIT MIN J 4 TO ACCOMMODATE THE SUM of AREAS OF ALL THE CABLES INSTALLED IN THE SAME CONDUIT. 1. USE CONDUCTORS SUITABLE FOR THE ENVIRONMENT. STRANDED WIRE MAY BE USED IF APPROVED BY AHJ. 2. EQUIVALENT WIRES (GAUGE, CLASSIFICATION, ETC.) BY OTHER MANUFACTURERS MAY BE USED. 3. UTP: UNSHIELDED TWISTED PAIR. STP: SHIELDED TWISTED PAIR. CO CO CO 00 N I- -,e N ti N M 00 Q a_ U � M Q Iz I O _ Q ``uJ vJ (n J N Z Q W Ly C)U U J o Q Q CD �O w Q ­t U F.- U NO. DATE REVISION DESCRIPTION z 05.02.19 PLAN REVIEW CORRECTIONS Q z i Cf`n7 V 0 J m L LU lVi/ �^^11 W aILL Z co N L0 Lu Q' W Cq rn O l5— V) Q O U a� 2 cr LL1 LL c () Q :2o z w .� U 0 w Q 0 3:M Lu m O -) U mOf O LL PROJECT NUMBER: PROJECT ENGINEER/DESIGNER: MICHAEL LUPSAIU DRAWN BY: DATE 1st ISSUED: MML 08-05-2019 SCALE: NOT TO SCALE SHEET TITLE: FIRE ALARM NOTES, CODES, SCHEDULES & SHEET INDEX SHEET NUMBER: FA-1.0 Iq FIRE ALARM EQUIPMENT LIST SYMBOL QTY. MANUFACTURER MODEL NO. DESCRIPTION CSFM FRCP 1 FIRE—LITE MS-9050UD FIRE ALARM CONTROL PANEL (FACP) — EXISTING 7167-0075:0210 ❑F 2 FIRE—LITE BG-12LX MANUAL PULL STATION 7150-0075:0184 ® 1 1 FIRE—LITE SystemSensor SD365 B300-6 SMOKE DETECTOR HEAD SMOKE DETECTOR BASE 7272-0075:0502 7300-1653:0109 4 FIRE—LITE MMF-301 ADDRESSABLE INPUT MODULE (MONITOR MODULE), MINIATURE 7300-0075:0185 1 SystemSensor PC2RL HORN —STROBE, MULTI—cd, CEILING, RED 7135-1653:0503 )( 2 SystemSensor SCRL STROBE, MULTI—cd, CEILING, RED 7125-1653:0504 O BY OTHERS BY OTHERS DUCT SMOKE DETECTOR — ooc 1 Mier Products, Inc BW—DocBox FIRE ALARM DOCUMENT CABINET; UL—LISTED (E478235) NOT APPLICABLE ❑ 1 BY OTHERS BY OTHERS WATER —FLOW SWITCH — osY 1 BY OTHERS BY OTHERS OS&Y KB 1 BY OTHERS BY OTHERS KNOX—BOX — j W 15 75 15 V- V1 V1 V1 (E) WIRES TO PHONE PHONE LINES TO 120V. AC POWER (DEDICATED CIRCUIT) RISER DIAGRAM SCALE.- NONE L I FACP I (E) FACP w/ 2 (E) PHONE JACKS VERIFY EXACT LOCATION SCOPE OF WORK: BUILDING 3, UNIT A T PARK LAND ADJACEI` RECREATIONAL � CEKM .c � � a (� LOADING 18 ry y POKM 20 OF s ( , i G ,a aw MAJOR °-- FUTURE . FRESHPC am RETAIlI:.. &EASY 13 PS Ncrr TD S C PIS 2 1 a928 SIP � ® 7,000 Sir EXCEED 3- TO E s + � tltl 7 DEVELOPED RYOTHERS 7 o s ADJACMt @Q l6 o d) 1A GOT4TRIR ® 11 i� ` LM 1� i 4 ix a: � J �• ffi ,8� , d 18 n r- ka..L m 12 2V PW 7& 14 . QPS'I e „ DRUG ' a 13,013 SF gg ToEEDEVELOPED 4 ® n rlv7 EW pT RM n RAM ORE 14 .a PAD A 1 a 4_5#00'SFGAS— ' ,8 NIMMAREA i 72 4 I ISOSF(.42AC) e POVM 07 12 , 9 DECELAMTMLAM —: - - T. CM nRONUMMT C �SITE PLAN- an SCALE.- NONE 0 e. EOL 0 if 1 ..•r.«... ..... r �.n� .rn ..r.,. rr ww TO FACP L i r 75 lift EOL Vl I I z EOL KB µ�r (E) KNOX- BOX. 64 IVERIFY EXACT LOCATION $ I rt q- i 7� i61—:1_F_ I �I r r� - .. r I I FLOOR PLAN- n d SCALE.- 118- = 1'_0- 77 1 NOT IN SCOPE , NOTES KEYNOTES 1. ALL CEILINGS ARE AT 11 FT. A.F.F., UNLESS TO 120V AC, DEDICATED POWER CIRCUIT. OTHERWISE NOTED. LOCK AND TAG CIRCUIT BREAKER PER NFPA-72 REQUIREMENTS. TO 120V AC DUCT SMOKE DETECTOR FOR MONITORING PURPOSES. FIELD -VERIFY EXACT LOCATION. DUCT SMOKE DETECTOR BY OTHERS. APPROVED Riverside County Fire Department La Quinta Office of the Fire Marshal B d e9 a �e,� oaamaa oN; o=us9 E=� lm rmx@u.aoa.y o=Ru,a oppmv Fo-a Y� Kohl Hetrick .,7�95-,T-p—La„naF��MasnaL��-Kon�Ra,,ak Location'. )8495 Calie Tampico, La QUln�d. 92253 countyfire 09/03/2019 2:02:40 PM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. 11 i I � � (E) FACP w/ 2 (E) PHONE JACK VERIFY EXACT LOCATION 1 FACP 1 L S ELEC RAC TO FACP 1 1 L v IETML A '�'f�. IIliF1R t)f9a 5'F ITPL 8 AMON 4ft10W Im raT+M Me 2: RETAMD.IL C. 1%x sr jav X5F 7rt37sE, Oft tIK !;F RETAIL D wa A%r :" * VIM m W3F &� BY TE.NW — r RETAIL �� =ww lak IN! IF i lam. FA2019-0009 3 z SCOPE OF WORK: BUILDING 3, UNIT A 140 V1 TO FACP ' :n '6 TO FACP I+ L � 1. V175 V F a? if f� �7 4 RTY U BOILER Rom, WATER HVkTFR W � ��� 1,t 5 4. A I _. __ II 04 04 ti ao rn 00 U TM_ rn m ° Q cw J O Z Q LL] w U_ U 1-0 J o Q 0 JoO w Q '�t U F.- U NO. DATE REVISION DESCRIPTION Al 05.02.19 PLAN REVIEW CORRECTIONS I— Z D 1 M 0 m o W c Q � LL co cu Z w w c� Lo U) N � o } ° U Q LU LL] LL o a Q LL U LU Q z W CY o LU co O c,3 (n m 0� O LL PROJECT NUMBER: PROJECT ENGINEER/DESIGNER: MICHAEL LUPSAIU DRAWN BY: DATE 1st ISSUED: MML 08-05-2019 SCALE: AS NOTED SHEET TITLE: FLOOR PLAN RISER CALCULATIONS SHEET NUMBER: FA- 2.0 I l 777 - II II I♦ � !�I. v^� � 20 i� ;fn i" ^=i %�\ (�' ■. - �II NG� � ■ � •. �a�� ■ � � :� a r__re o, Ih+li \�% iif_al � � � . I �� . .vim,, Iill�ll II�II FRCP NOTE: FACP AND PHONE LINE CONNECTIONS ARE EXISTING TO PHONE LINE 2 TO PHONE LINE 1 TO ADDRESSABLE INITIATING DEVICES STROBES V1 WIRING DIAGRAM - TYPICAL FIRE ALARM PERIPHERALS - TYPICAL FACP Battery Calculation Secondary Power Source Requirements Device Standby Current (amps) Secondary Alarm Current (amps) Qty Current Draw Total Qty Current Draw Total Main Circuit Board 1 1 jxj 0.120000 1=1 0.120000 1 1 jxj 0.257000 1=1 0,257000 Addressable Devices SD365 1 x 0.000300 = 0.000300 MMF-301 4 x 0.000375 = 0.001500 BG-12LX 2 x 1 0.000375 = 0.000750 Maximum alarm draw for all Addressable devices---------------> 0.20000 Output Circuits NACIOutput #1 0,000000 = 0,295000 = 0,295000 NACIOutput #2 0,000000 = 0,000000 = FCPS (remote Sync) 0 x 0.o00000 = a x 0.021700 = Total Standby Load 0.122550 Total Alarm Load 0.752000 Calculation in Total Sheet Required Standby Time in Hours 24 Hours Total Standby Current 0.1226 Amps x 24 1 = 1 2.941 A Required Alarm Time in Minutes 5 Minutes 11111 Total Alarm Load 0.7520 Amps x F 0.084 1 = 0.063 A H Total Current Load 3.004 AH Multiply by the Derating Factor 1.2 = x 1.20 Total Ampere Hours Required 3.61 A Batteries Provided*: BAT-1270 - 7AH Batteries " Two (2) batterry, each 12V @ 7Ah Voltage Drop Calculation CIRCUIT CKT CKT ON ON PANEL FLR.PLN. Hornistrobes V1 SPARE JV2 Formula for calculating Voltage Drop: Voltage( EL = Voltage@BG - (Total Current" 2 *Length* R) Votage @EL: at End of Line Voltage L7a BC, at Beginning of Circuit R-- Resistance / foot-ef-wire WIRE RESISTANCE/fact-of-wire 12GA = 0.00177 0,00200 14GA= 0.00282 0,00310 16GA = 0.00450 0-00500 Voltage at begining of cErcuit NOTES 1. Current draw shown is MAXIMUM (at lowest voltage of 16 V) CALCULATIONS APPROVED Riverside County Fire Department La Quinta Office of the Fire Marshal B DI91uIlY sl9netl by'O NeNck y . DN C=US E=koM1l M1eMck�fire ca goo O=Riversitle County Fire Kohl Hetrick L—timeIM95-LeD�ia,aD.e Q—,92253M1ai DN KOM1INe,tlk Location'. ]8496 Calle Tampico. La Quinta, 9 -r Contact Info: )60-]]]-IO)p s tlocumenl cou ntyfi re 09/03/2019 2:02:53 PM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. FA2019-0009 SCRL STROBES PG2RL HORN -STROBES LENGTH Wire Gauge Total Current [A] Voltage Drop 1%] Voltage at End of Line M A/V CEILING CEILING W.P. 15Cd 30Cd 75Cd 95Cd 110Cd 15cd 30Cd 75Cd 95Cd 110cd 0.041 0-063 -0111 -0134 0.000 0.071 0.090 0.143 0.165 0-000 OA76 1 1 1 1061 14 1 0.295 0.80!a 1 23.81 01 14 1 0.000 0.0% 1 24.00 TOTAL ClJRRENT 0.295 N 6' rn 00 U a)Q w m 0 J ti U) LU Q = LL] 2 U 1-0 _U J Q C) Q J O � O Lu Q ,1- U U NO. DATE REVISION DESCRIPTION Al 05.02.19 PLAN REVIEW CORRECTIONS Q z i CM J m L LU c Q � LL z O N 0 < o } Q0U LLI �) a_2 E IY LU ILL LU v C� (n J Lu Q o z Lu w O -) U7 O LL PROJECT NUMBER: PROJECT ENGINEER/DESIGNER: MICHAEL LUPSAIU DRAWN BY: DATE 1st ISSUED: M M L 08-05-2019 SCALE: NONE SHEET TITLE: FIRE ALARM CALCULATIONS AND DETAILS SHEET NUMBER: FA- 3.0 910-9113*3141 ES-50X Intelligent Addressable FACP with Communicator General The ES-50X is the latest intelligent addressable fire alarm control panel (FACP) from Fire-Lite Alarms and is a direct replacement for the MS-9050UD/LS. The ES-50X comes with a pre -installed communi-cator and supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the ES-50X programs just like Fire-Lite's other addressable panels, yet fits into applications previously served only by conventional panels. The pre -installed IPOTS-COM is a dual technology (POTS and IF) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL -MOD or CELL -CAB -FL. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk -test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTMF). Features • Listed to UL Standard 864, 10th edition • Pre -installed IPOTS-COM Ethernet IF and POTS (Plain Old Tele- phone Service) Central Station Communicator • Optional CELL -MOD or CELL -CAB -FL GSM Central Station Communicator overAlarmNet® • Compatible with SWIFT® wireless devices • Auto -programming (learn mode) reduces installation time. Reports two devices set to the same address • Two independently programmable, built-in Style Z (Class A) or Style Y (Class B) NAC circuits • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices • Notification Appliance Circuit End of Line resistor matching • Four programmable function keys for ease of maintenance • Two programmable relays and one fixed trouble relay • Built-in Programmer • Integral 80-character LCD display with backlighting • Real-time clock/calendar with automatic daylight savings control • History file with 1,000 event capacity • Addressable sounder base • Multi -criteria detector (smoke, heat, CO) with programmable response • Control module delay timer • Automatic detector sensitivity testing (NFPA 72 compliant) • Automatic device type -code verification • Point trouble identification • Waterflow selection per module point • Alarm verification selection per detector point (a Flre-ure°aLarms by Honeywell • Maintenance alert warns when smoke detector dust accumula- tion is excessive • One -person audible or silent walktest with walktest log & printout • System alarm verification selection per detector point • PAS (Positive Alarm Sequence) and Pre -signal per point (NFPA 72 compliant) • Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator • Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP Supports LiteSpeedTA4 and CLIP protocols SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire Single addressable SLC loop which meets NFPA Class B and Class A requirements 50 addressable device capacity (any combination of addressable detectors and modules) Compatible with Fire-Lite's addressable devices (refer to the SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NACS) • Two independently programmable output circuits. Circuits can be configured for the following outputs: — Style Y (Class B) — Style Z (Class A) • Silence Inhibit and Autosilence timer options • Continuous, March Time, Temporal, or California code for main circuit board NACs with two -stage capability • Selectable strobe synchronization per NAC • 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A PROGRAMMING AND SOFTWARE Autoprogramming (learn mode) reduces installation time DF-60953:C • 7/16/2018 — Page 1 of 4 • Custom English labels (per point) may be manually entered or selected from an internal library file • Two programmable Form-C relay outputs • 50 software zones • Continuous fire protection during online programming • Program Check automatically catches common errors not linked to any zone or input point • OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows® -based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.firelite.com. User interface LED INDICATORS • Fire Alarm (red) • CO Alarm (red) • AC Power (green) • Supervisory (yellow) • Trouble (yellow) • Ground fault (yellow) • Battery fault (yellow) • Disabled (yellow) • Maintenance (yellow) • Communication (yellow) • Alarm Silenced (yellow) • F1-F4 Programmable Function Keys (yellow) KEYPAD • 16 key alpha -numeric pad • Acknowledge • Alarm Silence • Drill (Manual Evacuate) • Four (4) programmable function keys • Reset (lamp test) Product Line Information ES-50X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pre -installed IPOTS-COM communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. (For ES-50XC, refer to DF- 60954.) FS-Tools: Programming software for Windows® -based PC com- puter. Available for download at www.firelite.com. CELL-CAB-FL/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the ES-50X. TR-CE: Optional trim ring for semi -flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries & CHG-75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi -modules in a BB-6F cabinet. CHG-75: Battery charger for lead -acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead -acid batteries with a rating of 55 to 120 AH. Requires additional BB-55F for mount- ing. BAT Series: Batteries, see data sheet DF-52397. PRN Series: UL listed compatible event printer. Uses tractor -fed paper. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. COMPATIBLE ANNUNCIATORS ANN-80: Remote, red LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. ANN-1/0: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DF- 60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. SD365: Addressable low -profile photoelectric smoke detector. Lite- Speed only. SD365-IV: Addressable low -profile photoelectric smoke detector. Ivory. LiteSpeed and CLIP mode. SD365T: Addressable low -profile photoelectric smoke detector with thermal sensor. LiteSpeed only. SD365T-IV: Addressable low -profile photoelectric smoke detector with thermal sensor. Ivory. LiteSpeed and CLIP mode. SD365R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. LiteSpeed only. SD365R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. Lite- Speed and CLIP mode. H365: Low -profile 135°F fixed thermal sensor. LiteSpeed only. H365-IV: Low -profile 135°F fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. H365R: Low -profile, intelligent, rate -of -rise thermal sensor. Lite- Speed only. H365R-IV: Low -profile, intelligent, rate -of -rise thermal sensor. Ivory. LiteSpeed and CLIP mode. H365HT: Low -profile intelligent 190°F/88°C fixed thermal sensor. LiteSpeed only. H365HT-IV: Low -profile intelligent 190°F/88°C fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. Legacy Devices SD355: Addressable low -profile photoelectric smoke detector. SD355T: Addressable low -profile photoelectric smoke detector with thermal sensor. SD355R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. SD355CO: Addressable, low -profile device that provides fire, heat, and carbon monoxide (CO) detection. H355: Fast -response, low -profile heat detector. H355R: Fast -response, low -profile heat detector with rate -of -rise option. H355HT: Fast -response, low -profile heat detector that activates at 190°F/88°C. Page 2 of 4 — DF-60953:C • 7/16/2018 AD355: Low -profile, intelligent, "Adapt' multi -sensor detector (13350LP base included). B20OS: Programmable, addressable sounder base B200SR: Addressable sounder base. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. D355PL: InnovairFlex low -flow non -relay duct -detector housing; includes SD355R. DNR: InnovairFlex low -flow non -relay duct -detector housing. (Order SD355R/SD365R separately.) DNRW: InnovairFlex low -flow non -relay duct -detector housing, with NEMA-4 rating. Watertight. (Order SD355R/SD365R separately.) Addressable Modules MMF-300: Addressable Monitor Module for one zone of normally - open dry -contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end -of -line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300. Addressable Monitor Module for one zone of conventional two -wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style Y/Z (Class B/ A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). ISO-6: Six -fault isolator module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SMB500: Used to mount all modules except MMF-301 and M301. MMF-300-10: Ten -input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six -zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six -circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six -relay control module (Form-C relays). Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SWIFT Wireless Devices W-GATE: LiteSpeed Wireless Gateway W-SD355: LiteSpeed intelligent, wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135°) heat detector. W-SD355T: intelligent wireless photo/heat detector. W-H355: LiteSpeed intelligent wireless fixed -temperature (135°) heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module. W-CRF: LiteSpeed Intelligent wireless relay module. W-BG12LX: LiteSpeed Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the ES-50X, see the following data sheets (document num- bers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 (DF-52386), BG-12LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/CRF Series (DF-52130), CP355 (DF-52383), H355 Series (DF-52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), SD355/SD355T (DF-52384), and SLC Wiring Manual (51309). NOTE: Legacy 300 Series detection devices such as the CP300/CP350, SD300(T)/SD350(T) and older modules such as the M300, M301, M302, C304, and BG-10LX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. ADDRESSABLE DEVICE ACCESSORIES End -of -Line Resistor Assembly (R-47K and R-3.91K): The 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, and CMF-300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted -pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. DF-60953:C - 7/16/2018— Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity • Intelligent Signaling Line Circuits................................................1 • Addressable device capacity....................................................50 • Programmable software zones.................................................50 • Annunciators.............................................................................16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto -sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead -acid batteries. Battery Charger Capacity: 7-18 AH (ES-50X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power -limited. Notification Appliance Circuits: Terminal Block provides connec- tions for two NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power -limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End -of -Line Resistor: 4.7k ohm, % watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 kQ - 22 kQ ELR range. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non -power -limited, non -supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. IS0 9001 WIMINI a AIAMIFAMRpB QNALITY SYSTEMS Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90oF ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27°C/60 — 80°F. NFPA Standards The ES-50X complies with the following NFPA 72 Fire Alarm Sys- tems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). — AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) — PROPRIETARY (Automatic, Manual and Waterflow). — CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). — OT, PSDN (Other Technologies, Packet -switched Data Net- work) — IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). — CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic ES-50X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S624 • FM approved • CSFM: 7165-0075:0500 • FDNY: COA #6261 NOTE: See DF-60954 for ULC-listed model. AlarmNet@, Fire-Lite@ Alarms, SWIFT@, and System Sensor@ are registered trademarks of Honeywell International Inc. Microsoft@ and Windows@ are registered trademarks of the Microsoft Corporation. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Country of Origin: USA Page 4 of 4 — DF-60953:C • 7/16/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE � LISTING No. 7165-0075:0500 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models ES-50X and ES-20OX Addressable Fire Alarm Control Units. Automatic, manual, waterflow, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. The ES-50X is a compact version of the ES-20OX. The ES-50X has 50 addressable device capability and 2 Notification Appliance Circuits with a 3.0 amps total 24VDC output in Alarm. The ES-20OX has 198 addressable device capability and 4 Notification Appliance Circuits with 3.Oamps total 24VDC output in Alarm expandable to 6.Oamps with Model PWRMOD24. The Model IPOTS-COM provides Phone and IP communication. Models ES-50X and ES-20OX system components are as follows IPOTS-COM POTS and IF Communicator 4XTMF Transmitter Module ANN-80 Remote Annunciator Module ANN-100 Remote Annunciator Module ANN-1/0 LED Driver Module ANN-S/PG Serial/Parallel Interface Module ANN-RLY Form-C Relay Module ANN-LED Annunciator Module ANN-RLED Annunciator Module CELL -MOD GSM Communicator DP-ES-R Dress Panel Model ES-20OX system components are as follows: PWRMOD24 NAC Power Expander Module Refer to the listee's data sheet for additional detailed product description and operational considerations. RATING: 120/24OVac 50/6OHz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units, emergency alarm system control units and process 01-31-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not sO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0075:0500 Page 2 of 2 management equipment for use with separately listed compatible initiating and indicating devices. Refer to Manufacturers Installation Instruction Manual for details. NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. 01-31-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not sO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52013:D • E-100 BG.12LX Addressable Manual Pull Station General The Fire-Lite BG-12LX is a state-of-the-art, dual -action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire -ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-1/0) or semi - flush mounted. Semi -flush mount to a standard single - gang, double -gang, or 4" (10.16 cm) square electrical box. • Smooth dual -action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications • Shipping Weight: 9.6 oz. (272.15 g) • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 VDC. • Maximum SLC standby current: 375 NA. • Maximum SLC alarm current: 5 mA. • Temperature Range: 32°F to 120°F (0°C to 49°C) • Relative Humidity: 10% to 93% (noncondensing) • For use indoors in a dry location Installation The BG-12LX will mount semi -flush into a single -gang, double - gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-1/0 surface back - box. If the BG-12LX is being semi -flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is (9 Fire•LITe°"ALarms by Honeywell a usually needed for semi -flush mounting with 4" (10.16 cm) or double -gang boxes (not with single -gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 — 159 with Breakaway Tab removed for MS-9600 Series, 1 — 99 and MS-92000DLS, 1 — 50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non -coded, with a key - operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red -colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi -flush mounting on a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box, and shall be installed DF-520130 • 4/13/2012 — Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual -action addressable pull station. Includes key locking feature. (Listed for Canadian and non -Canadian appli- cations.) SB-10: Surface backbox; metal. SB-1/0: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UUULC Listed: S711 (listed for Canadian and non -Cana- dian applications). • MEA:67-02-E. • CSFM:7150-0075:0184. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. FireLite@ Alarms@ is a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. IO0�� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. pM11BIMI SAll specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 — DF-520130 • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE � LISTING No. 7150-0075:0184 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-12SP, BG-12LR, BG-12LRA, BG-12LAO, BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-12SL, UT-PS1 and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not sO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D F-61010:A SD365(A) Series Addressable Photoelectric Detectors General The Fire-Lite SD365(A), SD365T(A), and SD365R(A) Series addressable plug-in photoelectric smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contempo- rary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with Fire-Lite's addressable fire alarm control panels, the SD365(A) Series point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The SD365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the SD365T(A) and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP • Two -wire loop connection. • Unit uses base for wiring. ADDRESSING • Addressable by device. • Rotary, decimal addressing: Please refer to the Fire-Lite panel manuals for device capacity. ARCHITECTURE • New modern profile for improved aesthetics. • Unique single -source design to respond quickly and dependably to a broad range of fires. • Integral communications and built-in type identification. • Built-in tamper -resistant feature. • Removable cover and insect -resistant screen for simple field cleaning. OPERATION • Designed to meet UL 268 7th Edition. • Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level. • Visible LED "blinks" when the unit is addressed (communicating with the fire panel) and latches on in alarm. • Low standby current. MECHANICALS • Sealed against back pressure. • Mounts to: single -gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (with or without a mud ring - not included). OPTIONS • Remote LED output connection, RA100Z. 8 Fire-uWaLarms by Honeywell SD365 Installation SD365(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class B) wiring. SD365R(A) mounts in a D355PL(A) or DNR(A) /DNRW duct detector housing. Operation Each SD365(A) Series detector uses one possible addresses on the Fire-lite Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an ES-50X or ES-20OX addressable fire alarm control panel. The results of the sensitivity test can be printed off the for record keeping. Specification Voltage range: 15 — 32 VDC (peak). Standby current: 200 pA @ 24 VDC. Max current: 4.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft./min. (20 m/sec.) maximum. Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter. — B300-6: 6.1" (15.6 cm) diameter. — B501: 4" (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4 oz. (95 g). DF-61010:A • 4/2/18 — Page 1 of 3 Operating temperature range: • SD365(A): 0°C to 50°C (32°F to 122°F); • SD365T(A): 0°C to 38°C (32°F to 100°F). • SD365R(A): installed in a DNR(A)/DNRW -20oC to 70oC (-4°F to 158°F). Relative humidity: 10%-93%, non -condensing. Listings Listings and approvals below apply to the SD365 Series detectors. In some cases, certain detectors may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC Listed: S1059 • CSFM:7272-0075-0502 • FM Approved Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. NOTE: "IV" suffix indicates LiteSpeed® and CLIP device. NOTE: "A" suffix indicates Canadian version. SD365(A): White, Addressable photoelectric detector; B300-6 base included. LiteSpeed only. SD365(A)-IV: Ivory, Addressable photoelectric detector; B300-6 base included. SD365T(A): White, Same as SD365 but with thermal element; B300-6 base included. LiteSpeed only. SD365T(A)-IV: Ivory, Same as SD365 but with thermal element; B300-6 base included. SD365R(A): White, Remote test capable addressable photoelectric detector for use with DNR(A)/DNRW. LiteSpeed only. SD365R(A)-IV: Ivory, Remote test capable addressable photoelec- tric detector; for use with DNR(A)/DNRW. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low -profile mounting base. (CSFM: 7300-1653:0109 Pending) B300-6-IV: Ivory,6" base, standard flanged low -profile mounting base. (CSFM: 7300-1653:0109 Pending) B300A-6: Same as B300-6, ULC listed. B30OA-6-IV: Ivory, 6" standard flanged low -profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. (CSFM: 7300-1653:0216 Pending) B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216 Pending) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224BI-WH: White, isolator detector base. (CSFM: 7300- 1653:0216 Pending) B224BI-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216 Pending) B224BIA-WH: White, isolator detector base, ULC listing. B224BIA-IV: Ivory isolator detector base, ULC listing. B20OS-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A) base. TR300-IV: Ivory, replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501(A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: Color Kit (includes cover and trim ring), white, 10-pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack. DF-61010:A • 4/4/18 — Page 2 of 3 iso 9oo1 FNRINEUUNC A IRMUFACTURINR QUALITY SYSTEMS FireLite® Alarms is a registered trademark of Honeywell International Inc. 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 3 of 3 — DF-61010:A • 4/4/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE � LISTING No. 7272-0075:0502 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR -SYSTEM TYPE -PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models SD365, SD365R and SD365T analog addressable, photoelectric smoke detectors for open area and duct installations. Model SD365T has a complementary heat detector. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models B200S and B200SR (CSFM Listing 7300-1653:0213), B20OS-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209), Fire-Lite duct detector housing Model D355PL (CSFM listing 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. XLF: 7272-0028:0503 02-01-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not sO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division INSTALLATION AND MAINTENANCE INSTRUCTIONS B300-6 and B300-6-IV 6" Plug-in Detector Bases SYSTEM SENSOR® 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 www.systemsensor.com SPECIFICATIONS Base Diameter: 6.1 inches (155 mm) Base Height: 0.76 inches (19 mm) Operating Temperature: Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at systemsensor.com. Electrical Ratings: Operating Voltage: 15 to 32 VDC Standby Current: 170 pA Listings: UL268 BEFORE INSTALLING Please read the System Smoke Detectors Application Guide, which provides detailed information on detector spacing, placement, zoning, wiring, and spe- cial applications. Copies of this application guide are available from System Sensor. NFPA 72 guidelines should be observed. NOTICE: This manual should be left with the owner/user of this equipment. IMPORTANT: The detector used with this base must be tested and maintained regularly following NFPA 72 requirements. The detector should be cleaned at least once a year. GENERAL DESCRIPTION The B300-6 and B300-6-IV are plug-in detector bases intended for use in an intelligent system, with screw terminals provided for power (+ and -), and remote annunciator connections. Communication takes place over the power lines (+ and -). BASE TERMINALS NO. FUNCTION 1 Power (-), Remote Annunciator (-) 2 Power (+ ) 3 Remote Annunciator (+ ) FIGURE 1. TERMINAL LAYOUT TERMINAL2 TERM INAL 1 C0127-07 MOUNTING This detector base mounts directly to 4-inch square (with and without plaster rings), 4-inch octagon, 31/2-inch octagon, and single gang junction boxes. To mount, remove the decorative ring by turning it in either direction to unhook the snaps, then separate the ring from the base. Install the base on the box using the screws supplied with the junction box and the appropriate mounting slots in the base. Place the decorative trim ring on the base and rotate it in either direction until it snaps into place. (See Figure 2.) FIGURE 2. MOUNTING DETECTOR TO BOX SNAP ON DECORATIVE RING 4 I SCREWS (NOTSUPPLIED) DETECTOR BASE I I I I I I I I I � I m0� �m : �BoXSUPPLIED) a�a �m m C2036-01 INSTALLATION AND WIRING GUIDELINES (SEE FIGURE 3) All wiring must be installed in compliance with all applicable local codes and any special requirements of the authority having jurisdiction. Proper wire gauges should be used. The conductors used to connect smoke detectors to control panels and accessory devices should be color -coded to reduce the like- lihood of wiring errors. Improper connections can prevent a system from re- sponding properly in the event of a fire. For signal wiring (the wiring between interconnected detectors), it is recom- mended that the wire be no smaller than 18 AWG (0.823 mm2). Wire sizes up to 12 AWG (3.31 mm2) may be used with the base. Make electrical connections by stripping about 8/8 inch (10 mm) of insulation from the end of the wire (use strip gauge molded in base). Then slide the wire under the clamping plate and tighten the clamping plate screw. Do not loop the wire under the clamping plate. (See Figure 4.) Check the zone wiring of all bases in the system before installing the detec- tors. This includes checking the wiring for continuity, correct polarity, ground fault testing and performing a dielectric test. The base includes an area for recording the zone, address, and type of detec- tor being installed. This information is useful for setting the detector head address and for verification of the detector type required for that location. Once all detector bases have been wired and mounted, and the loop wiring has been checked, the detector heads may be installed in the bases. I56-6566-001 11/17/2017 TAMPER -RESIST FEATURE NOTE: Do not use the tamper -resist feature if a removal tool will be used. The detector base includes a tamper -resist feature that prevents removal of the detector without using a small screwdriver or similar tool. To activate this feature, use needle -nose pliers to break the tab on the detector base as shown in Figure 5A. Then, install the detector. To remove the detector from the base once the tamper -resist feature has been activated, remove the decorative ring by rotating it in either direction and pulling it away from the base. Then, insert a small screwdriver into the notch, as indicated in Figure 5B, and press the plastic lever toward the mounting surface before rotating the detector counterclockwise for removal. The tamper -resist feature can be defeated by breaking and removing the plas- tic lever from the base. However, this prevents the feature from being used again. REMOTE ANNUNCIATOR (RA10OZ) Connect the remote annunciator between terminals 1 and 3 using the spade lug terminal included. The spade lug terminal is connected to the base termi- nal as shown in Figure 6. It is not acceptable to have three stripped wires under the same wiring ter- minal unless they are separated by a washer or equivalent means. The spade lug supplied with the model RA10OZ is considered an equivalent means. See Figure 3 for proper installation. FIGURE 3. TYPICAL WIRING DIAGRAM FOR 2-WIRE LOOP REMOTE CAUTION: DO NOT LOOP WIRE ANNUNCIATOR UNDER TERMINAL 1 OR 2. BREAK WIRE RUN TO PROVIDE w SUPERVISION OF CONNECTIONS. Q W o 0 0 I I DJO 3 3 3 1 t I pM o ® o o ® o o ® o I I.-z I J 0 (—) — — — — — — — — — — — — 91151 — — — — � I I —) -- CLASSAOPTIONALWIRING I ------------ C0129-02 FIGURE 4. TERMINAL WIRE INSTALLATION THIS NOTTHIS 0 nn C0473-00 FIGURE SA. ACTIVATE TAMPER -RESIST FEATURE PLASTIC LEVER BREAK TAB AT DOTTED LINE BY TWISTING TOWARD CENTER OF BASE C0130-00 FIGURE SB. DETECTOR REMOVAL USE SMALL -BLADED SCREWDRIVER TO PUSH PLASTIC LEVER IN DIRECTION OF ARROW C0130-00 FIGURE 6. CONNECTION TO REMOTE ANNUNCIATOR TERMINAL STRIPPED WIRE WIRE WITH SPADE LUG Please refer to insert for the Limitations of Fire Alarm Systems CO116-00 THREE-YEAR LIMITED WARRANTY System Sensor warrants its enclosed smoke detector base to be free from defects in ma- 12220 Rojas Drive, Suite 700, El Paso TX 79936 USA. Please include a note describing the terials and workmanship under normal use and service for a period of three years from malfunction and suspected cause of failure. The Company shall not be obligated to repair date of manufacture. System Sensor makes no other express warranty for this smoke or replace units which are found to be defective because of damage, unreasonable use, detector base. No agent, representative, dealer, or employee of the Company has the au- modifications, or alterations occurring after the date of manufacture. In no case shall the thority to increase or alter the obligations or limitations of this Warranty. The Company's Company be liable for any consequential or incidental damages for breach of this or any obligation of this Warranty shall be limited to the repair or replacement of any part of other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the smoke detector base which is found to be defective in materials or workmanship the Company's negligence or fault. Some states do not allow the exclusion or limitation of under normal use and service during the three year period commencing with the date of incidental or consequential damages, so the above limitation or exclusion may not apply manufacture. After phoning System Sensor's toll free number 800-SENSOR2 (736-7672) to you. This Warranty gives you specific legal rights, and you may also have other rights for a Return Authorization number, send defective units postage prepaid to: Honeywell, which vary from state to state. System Sensore is a registered trademark of Honeywell International, Inc. 2 I56-6566-001 ©2017 System Sensor. 11/17/2017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE � LISTING No. 7300-1653:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'I Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models B401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B402B, B404B, B404BT, B406B, B501, B501 B, 14506587-002, B501 BH, B501 BHT, B401 BH, B110LP, B110RLP, B110RLP750, 13112LP, B114LP, B114LPBT, 13116LP, B210LP, B501-BL, B501-IV, *B501-WHITE, B300-6, B300-6-IV, B300-6-IS detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, *model number, *electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. *Refer to Manufacturers Installation Instruction Manual for details. NOTE: Formerly 7300-1209:128 *Rev 04-03-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not sO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division INSTALLATION AND MAINTENANCE INSTRUCTIONS MMF-301 Monitor Module Firelffe®aLarms by Honeywell One FireLite Place Northford, CT 06472 Phone: 203.484.7161 SPECIFICATIONS Nominal Operating Voltage: 15-32 VDC Average Operating Current: 375 pA (group poll); 350 pA (direct poll); 600 pA Maximum (Communicating, IDC Shorted) EOL resistance: 47K ohms Maximum IDC Resistance: 1,500 Ohms Maximum IDC Voltage: 11 Volts Maximum IDC Current: 450 pA Temperature Range: 32°F to 120° F (0-C to 49° C) Humidity: 10% to 93% Non -condensing Dimensions: 1.3" H x 2.75" W x 0.65" D Wire length: 6" minimum BEFORE INSTALLING This information is included as a quick reference installation guide. Refer to the control panel installation manual for detailed system information. If the modules will be installed in an existing operational system, inform the opera- tor and local authority that the system will be temporarily out of service. Dis- connect power to the control panel before installing the modules. NOTICE: This manual should be left with the owner/user of this equipment. GENERAL DESCRIPTION The MMF-301 monitor module can be installed in a single gang junction box directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting (see Figure 1). The MMF-301 is intended for use in intelligent, two -wire systems where the individual address of each module is selected using rotary switches. It provides a two -wire initiating cir- cuit for normally open contact fire alarm and security devices. This module can be used to replace an M301 module in existing systems. COMPATIBILITY REQUIREMENTS To ensure proper operation, this module should only be connected to listed compatible system control panels only. FIGURE 1: MOUNTING AND WIRING NOTE: This module is intended to be wired and mounted without rigid con- nections inside a standard electrical box. All wiring must conform to appli- cable local codes, ordinances, and regulations. 1. Connect the red (+) and black (-) wires to the positive and negative loop power leads of the Signaling Line Circuit (SLC). 2. Connect the violet (+) and yellow (-) wires to a two -wire, normally open initiating loop. 3. Install the specified EOL resistor value to terminate the initiating loop. 4. Set the address on the module per job drawings. 5. Install the module in the desired mounting location. FIGURE 2. TYPICAL 2-WIRE STYLE B INITIATING DEVICE CIRCUIT (IDC) CONFIGURATION: UL LISTED COMPATIBLE CONTROL SIGNAL LINE CIRCUIT (SLC) PANEL (+)TO r NE J � NEXT (_) DEVICE ALL WIRING SHOWN IS SUPERVISED AND TENS ONES POWER LIMITED (_) W W (-) YELLOW VIOLET RED 47k EOL INCLUDED (ELR-47k) C0614-02 C1063-00 FL-460-004 1 I56-3654-002 m2008 FireLite Alarms Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE � LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: 'Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not sO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 4,�� SYSTEM Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Agency Listings SIGNALING &APPROVED LISTED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS868-02 - 12/01/2017 • Page 3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE � LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135 -- AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'I Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: System Sensor Indoor 2-wire and *4-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-62, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR-2 and *TR-2W CeilingTrim Rings: *TRC-2 and *TRC-2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not sO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not sO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE � LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'I Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-62, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBCWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. `Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not sO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. `Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not sO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division L-Series Specifications General L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double - gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02. 12/01/2017 • Page 2 UL Current Draw Data RIJNMFVf1RjM- T.i. nja;' 1IFFSL*Irii1MECi11 L max. 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16--,33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non -Temporal High 43 47 54 95 N/A 134 164 Non -Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.11K Non -Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non -Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non -Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.11K Non -Temporal High 108 135 179 200 225 255 289 3.1 K Non -Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 L-Series Dimensions 0.83" di (173 n 2.47" (62.7 mm) 1.37" (34.8 min) Ceiling -Mount Horn Strobes A0545-00 A0494-01 6.92" r+— (175. Ceiling Surface Mount Back Box 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories 2.5' (64 mm) O A0546-00 TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling -listed horn -only device, see AVDS865 "Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications". 1-01 SYSTEM ©t to c System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensoccom SENSOR" Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,6,-02ngthe latestversion ofthisdata sheet. AVDS868-02 • 12/01/2017 ROler DUCTS, INC. P DOcBOXES Instruction, Installation, and -4 21Iltenahee Nfanual BW-DocBox BW-DOCBox (15"Wx 13"Hx 4"D) • UL/c-UL Listed • THREE labels: "Fire Alarm Documents" "As Built Permits" "Test and Maintenance Documents" • An adjustable bungee allows you to fit various sizes of binders, documents, smoke -cans, etc. • A door bracket holds two CDs, three sets of keys and more documents • A cam lock with two keys 13W-DOCBox2 (11 "Wx 15"Hx 4"D) Smaller model without the door bracket. MADE I/V O� 7�ER25��� The door can be left blank, or one of the three labels may be used. need?see the enclosure you Other colors, graphic screening, r e-mail us and we'll be happy to help! and customization are available for quantities of 25 or more. wow Indoor & Outdoor Electrical Enclosures I Drive -Alert Vehicle Detection & Asset Protection Systems I Custom Fabrication 800-473-0213 — info@mierproducts.com — www.mierproducts.com Regency Centers. July 30, 2019 RE: ALL SPORTS CLUB, INC —JEFFERSON SQUARE 44-025 JEEFERSON STREET, SUITE 101 LA QUINTA, CA 92253 To Whom It May Concern, 420 Stevens Avenue Suite 320 Solana Beach, CA 92075 858 847 4600 RegencyCenters.com This letter is to confirm that, as of July 10, 2019, Regency Marinita — La Quinta, LLC has entered into a Lease with All Sports Club, Inc. The tenant has the right to make modifications to the premises including alterations to the fire system which specifically services their suite. Please contact me directly with any questions or concerns: lborenstein@regencyicenters.com or 858-847-4500. Sincerely, Laura Borenstein-Hofman Sr Property Manager CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org September 3, 2019 Alarmas Baja 48909 Charlton Peak Street Coachella, CA 92236 Re: Fire Alarm System Plan Review — Jefferson Square Bldg 3 FA2019-0009 / 44025 Jefferson St, Ste 101, La Quinta, CA 92253 The fire alarm system plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough -Wire Inspection — all wire not in conduit is exposed for inspection. b) Function Test / Start 24-hour Battery - The alarm installer shall provide all needed testing equipment to complete the final alarm inspection. c) 5-Minute Ring -out / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings ("as builds"), site -specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist RIVERSIDE COUNTY FIRE PROTECTION PLANNING t. RECORD OF INSPECTIONS / PERMIT CARD. �Cv THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.—cnuroRNfA— INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 44025 Jefferson St #101 PERMIT#: FA2019-0009 DATE SUED: 9/3/2019 DESCRIPTION: JEFFERSON SQUARE BLDG 3 CONTRACTOR: ALARMAS BAJA HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre -pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final EF Thrust block pre -pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors' test Hood/duct extinguishing High pile storage High pile rack storage In -rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough -wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131