FA2019-0010ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE KAYLI ALFORD 9/3/2019 9/3/2019 OTIS TAYLOR CAME TO PICK UP THE PLANS AND JOB CARD. NOTE KOHL HETRICK 2/28/2020 3/5/2020 PROVIDED AS-BUILT PLANS. SEE ATTACHMENTS PUBLIC COUNTER VISIT AARON HICKSON 1/9/2020 1/9/2020 CONTRACTOR PAID REINSPECTION FEE PUBLIC COUNTER VISIT JACK LIMA 11/19/2019 11/19/2019 REVISION 1 PLANS AND CALCULATIONS PICKED UP BY PETE CAMEJO. SUBMITTAL JACK LIMA 8/15/2019 8/15/2019 1ST SUBMITTAL MADE BY CRAIG NYBERG OF JJJ ENTERPRISES. TELEPHONE CALL KAYLI ALFORD 1/8/2020 1/8/2020 SPOKE TO PETE CAMEJO AND INFORMED HIM THAT THE FEES WERE OUTSTANDING AND PERMIT COULD NOT BE FINALED UNTIL FEES WERE PAID. HE STATED HE WOULD BE OVERNIGHTING A CHECK. AFTER THE 1/8/20 INSPECTIONS WERE COMPLETED, IT WAS DETERMINED AN ADDITIONAL REINSPECTION FEE WOULD BE ASSESSED, PER KOHL, AND A VOICEMAIL WAS LEFT FOR PETE TO INFORM HIM. Description: FLOOR & DECOR / BCOM2019-0016 / FIRE ALARM SYSTEM Type: FIRE ALARM Subtype: COMMERCIAL - FIRE ALARM SYSTEM Status: FINALED Applied: 8/15/2019 JLIM Parcel No: 600020028 Site Address: 79315 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 8/29/2019 KHET Subdivision: PM 33588 Block: Lot: 2 Issued: 9/3/2019 KAL Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/9/2020 crw Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Wednesday, January 25, 2023 3:48:28 PM 1 of 5 Permit Details City of La Quinta PERMIT NUMBER FA2019-0010 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT THE STEINHILBER CORPORATION DBA JJJ ENTE PO BOX 463021 ESCONDIDO CA 92046 CONTRACTOR THE STEINHILBER CORPORATION DBA JJJ ENTE PO BOX 463021 ESCONDIDO CA 92046 OWNER CENTRE AT LA QUINTA PARTNERS 3 HAMILTON LANDING NO 200 NOVATO CA 92253 CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST KAYLI ALFORD 11/5/2019 11/19/2019 COMPLETE FEES DUE PRIOR TO REVISED PLAN SET ISSUANCE FEES PAID 11/19/19 CONDITIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE ALARM SYSTEMS 101-0000-42421 0 $481.00 $481.00 8/15/19 R52642 47372 CHECK CRAIG NYVERG - THE STEINHILBER JLIM FIRE ALARM SYSTEMS PC 101-0000-42420 0 $560.00 $560.00 8/15/19 R52642 47372 CHECK CRAIG NYVERG - THE STEINHILBER JLIM FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 1/9/20 R58030 48020 CHECK THE STEINHILBER CORPORATION DB AHI FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 1/9/20 R58028 47992 CHECK THE STEINHILBER CORPORATION DB AHI FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 1/9/20 R58028 47992 CHECK THE STEINHILBER CORPORATION DB AHI Printed: Wednesday, January 25, 2023 3:48:28 PM 2 of 5 Permit Details City of La Quinta PERMIT NUMBER FA2019-0010 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH-WIRE INSPECTION KHET 10/21/2019 10/21/2019 PARTIALLY APPROVED Partial - Hard-lid Areas Only ROUGH-WIRE INSPECTION KHET 11/26/2019 11/26/2019 APPROVED FUNCTION TEST KHET 12/5/2019 12/5/2019 PARTIALLY APPROVED Device Installation Check Only Need to Function Test once programing is complete. Permanent Power supply from circuit is still required. Communication to Central Station is required as part of TCO for Stock & Train. DUCT DETECTORS/VELOCITY KHET 12/5/2019 12/5/2019 NOT READY Will perform after TCO but prior to OCCf FUNCTION TEST KHET 12/6/2019 12/6/2019 DISAPPROVE D Pull station, smoke detector and waterflow activations were not sending signals to the panel. Was able to test all A/V notification appliances via "Fire Drill". All devices operated, but require synchronization. DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE STAFF - PER HOUR 101-0000-42420 1 $160.00 $160.00 11/19/19 R56182 47803 CHECK CRAIG NYVERG - THE STEINHILBER JLIM Total Paid for FIRE FEES: $1,684.00 $1,684.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 8/15/19 R52642 47372 CHECK CRAIG NYVERG - THE STEINHILBER JLIM Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 8/15/19 R52642 47372 CHECK CRAIG NYVERG - THE STEINHILBER JLIM Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$1,699.00 $1,699.00 Printed: Wednesday, January 25, 2023 3:48:28 PM 3 of 5 Permit Details City of La Quinta PERMIT NUMBER FA2019-0010 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/3/2019 KAYLI ALFORD FIRE JOB CARD FIRE JOB CARD.doc BOND INFORMATION SPRINKLER MONITORING KHET 12/6/2019 12/6/2019 DISAPPROVE D Fire Alarm was not able to receive signal from the tamper switches and waterflow.. FUNCTION TEST KHET 12/9/2019 12/9/2019 APPROVED A/V operated and was sequenced Function test performed to confirm system can operate and allow Stock and Train. SPRINKLER MONITORING KHET 12/9/2019 12/9/2019 PARTIALLY APPROVED PIV has trouble. New DCDA to be installed, may be monitored. SPRINKLER MONITORING KHET 1/7/2020 1/7/2020 APPROVED DUCT DETECTORS/VELOCITY KHET 1/8/2020 1/8/2020 APPROVED 24 HR. BATTERY TEST KHET 1/8/2020 1/8/2020 APPROVED FIRE FINAL**KHET 1/8/2020 1/8/2020 DISAPPROVE D SEE ATTACHMENTS FIRE FINAL**KHET 3/9/2020 3/9/2020 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) JACK LIMA 8/15/2019 8/16/2019 8/15/2019 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 8/15/2019 8/29/2019 8/29/2019 APPROVED 1ST FIRE (1 WK)KOHL HETRICK 10/23/2019 10/30/2019 11/5/2019 APPROVED- CONDITIONS REVISION 1: CHANGES TO ALARM REVISION WILL BE CHARGED AT TIME OF ISSUANCE FOR TIME SPENT ON PERMIT. PARENT PROJECTS Printed: Wednesday, January 25, 2023 3:48:28 PM 4 of 5 Permit Details City of La Quinta PERMIT NUMBER FA2019-0010 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/29/2019 KOHL HETRICK FA2019-0010 - FLOOR and DECOR - FA LTR OF COND..pdf FA2019-0010 - FLOOR and DECOR - FA LTR OF COND..pdf 1 DOC 1/9/2020 KOHL HETRICK FA2019-0010 - 1-8-20 - FIRE CORRECTIONS.pdf FA2019-0010 - 1-8-20 - FIRE CORRECTIONS.pdf 0 DOC 3/5/2020 KOHL HETRICK FA2019-0010 - FLOOR and DECOR - JJJ ENT - AS BUILTS.pdf FA2019-0010 - FLOOR and DECOR - JJJ ENT - AS BUILTS.pdf 1 Printed: Wednesday, January 25, 2023 3:48:28 PM 5 of 5 Permit Details City of La Quinta PERMIT NUMBER FA2019-0010 131412LOCATE THE ADDRESSABLE RELAY MODULE (ACM) WITHIN THREE (3) FEET OF THEASSOCIATED RTU CONTROLLER. PROVIDE ANY REQUIRED WIRING ANDCONNECTIONS FOR GLOBAL RTU SHUTDOWN. COORDINATE CONNECTIONS WITHTEMPERATURE CONTROLS, MECHANICAL, ELECTRICAL, AND GENERALCONTRACTORS.DUCT DETECTORS ARE NOT REQUIRED OR PROVIDED IN THIS HVAC UNIT THAT HAS ADESIGN CAPACITY EQUAL TO OR LESS THAN 2,000 CFM.PROVIDE REMOTE TEST STATIONS/ANNUNCIATORS FOR EACH DUCT DETECTOR.PROVIDE ANY REQUIRED POWER CABLING CONNECTIONS TO DETECTORS ANDREMOTE TEST STATIONS/ANNUNCIATORS. CLEARLY LABEL REMOTE TESTSTATIONS/ANNUNCIATORS TO INDICATE RETURN OR SUPPLY SIDE & ASSOCIATEDROOFTOP UNIT. MOUNT THE REMOTE TEST STATIONS/ANNUNCIATORS ON ANADJACENT COLUMN OR WALL, AND AT AN ACCESSIBLE LOCATION THAT DOES NOTCONFLICT WITH STORE FIXTURES. COORDINATE EXACT MOUNTING LOCATIONS WITHTHE GENERAL CONTRACTOR, OWNER, AND THE AHJ PRIOR TO INSTALLATION.15LOCATE MODULES ADJACENT TO THE PUBLIC ADDRESS SOUND SYSTEM HEAD-ENDEQUIPMENT FOR BACKGROUND MUSIC SYSTEM OVERRIDE (AS INDICATED IN THEPROGRAMMING MATRIX). PROVIDE CIRCUITS TO THE PUBLIC ADDRESS SOUNDSYSTEM HEAD-END EQUIPMENT. FINAL WIRING CONNECTIONS IN THE HEAD-ENDEQUIPMENT ARE BY THE ELECTRICAL AND TELECOMMUNICATION SYSTEMCONTRACTORS. COORDINATE INTERFACE CONNECTIONS WITH THE ELECTRICAL ANDTELECOMMUNICATION SYSTEM CONTRACTORS.16PROVIDE A PHONE SURGE SUPPRESSION MODULE FOR THE PHONE LINE UTILIZED ASA MEANS OF SIGNAL TRANSMISSION FROM THE FACP TO THE OFF-SITE MONITORINGFACILITY FOR MONITORING OF ALARM, SUPERVISORY, AND TROUBLE CONDITIONS.INSTALL MODULE IN ACCORDANCE WITH THE NEC AND MANUFACTURER'SINSTRUCTIONS.17PROVIDE TRANSIENT SUPPRESSION ON ALL FIRE ALARM CIRCUITS LOCATED INUNDERGROUND CONDUIT. PROVIDE ONE (1) TRANSIENT SUPPRESSION MODULE FOREACH FIRE ALARM CIRCUIT. FIRE ALARM CABLING IN UNDERGROUND OR EXTERIORCONDUIT SHALL BE LISTED FOR WET LOCATIONS.18FIRE ALARM CABLING FROM THE FLOOR AND DECOR SPACE TO THE FIRE SPRINKLERRISER INSTALLED OUTSIDE OF THE FLOOR AND DECOR SPACE SHALL BE INSTALLEDIN METALLIC CONDUIT, LOCATED AT THE DECK, TO PROTECT AGAINST DAMAGE. FIREALARM CONDUIT SHALL BE CLEARLY LABELED TO INDICATE THAT THE CONDUIT ISFOR THE FLOOR AND DECOR SPACE.19COORDINATE THE LOCATION OF THE EXISTING UNDERGROUND CONDUIT TO THEEXTERIOR BACKFLOW PREVENTER / EXTERIOR POST INDICATOR VALVE (PIV).PROVIDE MONITORING OF ALL TAMPER SWITCHES (BY OTHERS) ON THE BACKFLOWPREVENTER / PIV UTILIZING EXISTING UNDERGROUND OR EXTERIOR CONDUIT.COORDINATE INTERFACE CONNECTIONS WITH THE OWNER'S REPRESENTATIVE, FIRESPRINKLER CONTRACTOR AND SITE CIVIL CONTRACTOR.1110643PROVIDE SYNCHRONIZATION OF ALL NOTIFICATION APPLIANCE CIRCUITSTHROUGHOUT THE FLOOR AND DECOR. PROVIDE ALL REQUIRED SYNCHRONIZATIONMODULES AND CABLING CONNECTIONS. PROVIDE MULTI-SYNC MODE SLAVECONNECTIONS TO ALL AUXILIARY POWER SUPPLIES (APS).PROVIDE TWO (2) MEANS OF SIGNAL TRANSMISSION TO THE OFF-SITE MONITORINGFACILITY. PRIMARY MEANS SHALL UTILIZE A DEDICATED PHONE LINE. THESECONDARY MEANS SHALL UTILIZE A PHONE LINE CONFIGURED WITH LINE SEIZURE.5PROVIDE A DOCUMENTATION CABINET ADJACENT TO THE FIRE ALARM CONTROLPANEL TO HOUSE ALL SYSTEM DOCUMENTS IN ACCORDANCE WITH NFPA 72. SYSTEMDOCUMENTS SHALL INCLUDE (AT A MINIMUM) RECORD DRAWINGS, EQUIPMENT DATASHEETS, SOFTWARE AND FIRMWARE CONTROL DOCUMENTATION. THEDOCUMENTATION CABINET SHALL BE PROMINENTLY LABELED “SYSTEM RECORDDOCUMENTS”, AND SHALL BE ACCESSIBLE BY AUTHORIZED PERSONNEL ONLY ANDPROTECTED FROM PUBLIC ACCESS.PROVIDE A REMOTE LCD FIRE ALARM ANNUNCIATOR WITH THE CAPABILITY TOPERFORM ALL FUNCTIONS AS OUTLINED IN THE DRAWINGS AND SPECIFICATIONS.COORDINATE EXACT MOUNTING LOCATION WITH THE GENERAL CONTRACTOR,OWNER, AND AHJ PRIOR TO INSTALLATION.7PROVIDE ELECTRONIC MONITORING OF ALL SPRINKLER WATERFLOW SWITCHES ANDCONTROL VALVE TAMPER SWITCHES (BY OTHERS). COORDINATE EXACT QUANTITIESAND INTERFACE CONNECTIONS WITH THE SPRINKLER CONTRACTOR.8MOUNT THE EXTERIOR WATERFLOW NOTIFICATION APPLIANCE AT TEN (10) FEETABOVE GRADE. COORDINATE EXACT MOUNTING LOCATION WITH THE GENERALCONTRACTOR, OWNER, AND AHJ PRIOR TO INSTALLATION.9PROVIDE ONE (1) MANUAL PULL STATION ADJACENT TO THE FIRE ALARMANNUNCIATOR. COORDINATE FINAL LOCATION WITH OWNER AND AHJ PRIOR TOINSTALLATION.MOUNT SMOKE DETECTOR ON THE BOTTOM OF THE FINISHED CEILING AND LOCATEDMORE THAN THREE (3) FEET FROM ANY MECHANICAL DIFFUSERS, AS INDICATED INNFPA 72.PROVIDE AN ADDRESSABLE INPUT MODULE (AIM) FOR MONITORING OF THE SUPPLYSIDE DUCT SMOKE DETECTOR (FACTORY INSTALLED). PROVIDE CONNECTIONS TOTHE ALARM AND TROUBLE CONTACTS TO INITIATE AN ALARM CONDITION WITHOUTBEING AFFECTED BY THE STATUS OF THE TROUBLE CONTACTS.2FIRE ALARM KEYED NOTES1PROVIDE CONNECTIONS TO DEDICATED 120 VAC POWER CIRCUITS WITH THEELECTRICAL CONTRACTOR. PROVIDE SURGE SUPPRESSION FOR 120 VAC POWERCIRCUITS. THE DEDICATED CIRCUIT DISCONNECT SHALL BE RED IN COLOR, LABELED"FIRE ALARM CIRCUIT", AND HAVE A LOCKABLE TAB. ALL FIRE ALARM CIRCUITBREAKERS SHALL BE CLEARLY MARKED AND MECHANICALLY SECURED TO PREVENTANY UNAUTHORIZED TAMPERING. IDENTIFY THE LOCATION OF THE CIRCUITDISCONNECT AT THE FACP AND EACH APS. PROVIDE 24 HOUR BATTERY BACKUP INTHE FACP AND EACH APS.PROVIDE AUXILIARY POWER SUPPLIES (APS) IN SUFFICIENT QUANTITIES TO POWERALL OCCUPANT NOTIFICATION APPLIANCES WITHIN THE FLOOR AND DECOR SPACE.PROVIDE A MEANS TO TRIGGER AND MONITOR EACH BANK OF APS FOR TROUBLECONDITIONS IN ACCORDANCE WITH NFPA 72.1. SEE WIRING LEGEND FOR CABLE TYPES AND SIZES.2. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCALADOPTED CODES.3. EXACT CABLE ROUTING TO BE COORDINATED WITH OTHER TRADES IN THE FIELD.SEE SPECIFICATIONS AND DRAWING NOTES FOR ACCEPTABLE INSTALLATIONMETHODS.5. ALL FIRE ALARM CABLING WITHIN THE BUILDING SHALL BE PLENUM RATED TYPEFPLP. SEE WIRING LEGEND FOR CABLE TYPES AND SIZES.6. FIRE ALARM CABLING SHALL NOT BE PAINTED.7. FIRE ALARM CABLING SHALL BE RED IN COLOR, SHALL BE LABELED AS FIRE ALARMCABLING, AND SHALL BE LISTED FOR THE INTENDED APPLICATION.14. ALL FIRE ALARM CABLING, IN ELECTRICAL AND MECHANICAL ROOMS (SUBJECT TOPHYSICAL DAMAGE), CONCEALED ABOVE CEILINGS OR IN PARTITIONS (SUBJECT TOPHYSICAL DAMAGE) SHALL BE INSTALLED IN METALLIC CONDUIT.15. ALL POWER LIMITED FIRE ALARM CABLING ABOVE THE STRUCTURE, ABOVE LAY-INCEILINGS, OR CONCEALED ABOVE CEILINGS OR IN PARTITIONS (NOT SUBJECT TOPHYSICAL DAMAGE) ARE NOT REQUIRED TO BE INSTALLED IN CONDUIT.22. FIRE ALARM CONDUCTORS SHALL BE ACCEPTABLE TO THE FIRE ALARMEQUIPMENT MANUFACTURER FOR THE INTENDED PURPOSE. SHOULDMANUFACTURER OF FIRE ALARM EQUIPMENT REQUIRE DIFFERENT TYPE OR SIZEOF CABLE THAN HEREIN SPECIFIED, THE LARGER OR MORE STRINGENT TYPE OFCABLE SHALL BE USED.23. CONDUIT AND CABLING SHALL ENTER INTO THE FACP AND EACH APS ONLY ASAPPROVED BY THE EQUIPMENT MANUFACTURER.21. ALL CABLING, CONDUIT, AND BACKBOXES SHALL BE PROPERLY SUPPORTED ANDSEISMICALLY BRACED, IF REQUIRED BY ALL APPLICABLE CODES AND THE LOCALJURISDICTION.17. ALL CONDUIT LOCATED IN DRYWALL SHALL BE TERMINATED NO LESS THAN SIX (6)INCHES ABOVE THE CEILING TILE.18. FOR DRYWALL APPLICATIONS, ALL CONDUIT AND BACKBOXES SHALL BERECESSED INSIDE THE WALL.19. ALL FIRE ALARM CABLING IN FINISHED AREAS SHALL BE CONCEALED.20. COORDINATE DRILLING OF ANY HOLES (I.E. COLUMN PENETRATIONS) WITH THEGENERAL CONTRACTOR AND ALL OTHER TRADES PRIOR TO INSTALLATION.16. ALL CONDUIT SHALL BE TERMINATED AT THE BAR JOIST LEVEL WITH SOME FORMOF GROMMET OR BOX CONNECTOR.8. ALL CABLE RUNS SHALL BE NEATLY BUNDLED, WRAPPED TIGHT AND PROPERLYSECURED. ANY CABLING NOT INSTALLED IN A NEAT AND PROFESSIONAL MANNERSHALL BE PULLED OUT AND RE-RUN BY INSTALLER.9. CONTRACTOR RUNNING CABLING MUST MARK BOTH ENDS OF CABLING, PROVIDE AWIRE LEGEND FOR ALL LOCATIONS, AND PROVIDE A CONTINUITY TEST LOG FOREACH CABLE.10. EXPOSED CABLING SHALL BE RUN PARALLEL AND PERPENDICULAR TO BUILDINGSTRUCTURE. EXPOSED CABLING SHALL NOT BE RUN IN A "SPAN" FASHIONBETWEEN BAR JOISTS OR BEAMS (I.E.: CABLING SHALL BE ROUTED ALONG PATHOF JOISTS AND BEAMS). ALL CABLING SHALL BE SECURED TO THE STRUCTURALCEILING BETWEEN JOISTS OR BEAMS, AND AS INDICATED IN SPECIFICATIONS.11. ALL CABLING SHALL BE SUPPORTED FROM BUILDING STRUCTURE AND NOT FROMGRID, TILES, OR SUPPORT WIRES. EXPOSED CABLING SHALL BE SUPPORTED BYBUILDING STRUCTURE AT NO MORE THAN FIVE (5) FOOT INTERVALS.12. ALL JUNCTION BOXES AND CABLE SPLICES SHALL BE ACCESSIBLE FOR SERVICE.PROVIDE ANY REQUIRED ACCESS PANELS.13. ALL EXPOSED VERTICAL CABLING SEVEN (7) FEET ABOVE THE FINISHED FLOORSHALL BE INSTALLED IN METALLIC CONDUIT.4. PROVIDE ALL REQUIRED CONDUIT, BACKBOXES, AND FITTINGS FOR THE FIREALARM SYSTEM CABLING. THE FIRE ALARM CONTRACTOR SHALL COORDINATEWITH THE ELECTRICAL CONTRACTOR TO DETERMINE THE EXTENT OF ALL FIREALARM CONDUIT AND BACKBOX REQUIREMENTS.FIRE ALARM INSTALLATION NOTESBUILDING/PROJECT DATASCOPE OF WORKDEVICE LEGEND NOTIFIERENGINEERED SYSTEMS COMPANY, INCENTERPRISESGENERAL NOTESSHEET INDEXABBREVIATIONSFA-1CENTRAL STATION INFORMATIONSEQUENCE OF OPERATIONSCONDUIT FILLVICINITY MAP··RTSAPPLICABLE CODES & STANDARDSWIRE LEGENDFLOOR & DECOR 79315 HIGHWAY 111 LA QUINTA, CA 92253ASBUILT02-18-20 MONITORCEMOFFICE115TRAININGROOM110VAULT112CORR. 2111CASHROOM113ASSIST.MGR.114U/CSAFEAOMAOMRTSNNNNNNNNNNNNNNNNNNLLLLLA,PA,PMATCHLINE SEE FA-3 MATCHLINE SEE FA-2MATCHLINE SEE FA-4MATCHLINE SEE FA-2MATCHLINE SEE FA-3 MATCHLINE SEE FA-2MATCHLINE SEE FA-4MATCHLINE SEE FA-2N.I.CNNNNNNNN121114121114233101518RTSMONITOR CEMOFFICE115TRAININGROOM110VAULT112CORR. 2111CASHROOM113ASSIST.MGR.114BREAKROOM109MEN'S105CORR. 1108GF.5STOCKROOM103FE.5ED.9SALES102DC.9D.2D.5C.5CMONITOR B.5DESIGNCENTER120WOMEN'S106JANITOR'SROOM107SIGNROOM117DATAROOM116G.5HDESIGNBUILDROOM118CPU104VESTIBULE101BA.2U/CSAFE MONITOR AOMRTS AOMAOMAOMAOM AOMAOM AOM AOM RTS RTS RTS RTS RTS RTS RTS18 RTS NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNLLLL LLLLL LL L LLLL LL LLLL LA,PA,PA,PA,PA,PMATCHLINE SEE FA-3 MATCHLINE SEE FA-2 MATCHLINE SEE FA-5 MATCHLINE SEE FA-4 MATCHLINE SEE FA-5MATCHLINE SEE FA-3MATCHLINE SEE FA-4MATCHLINE SEE FA-2MATCHLINE SEE FA-3 MATCHLINE SEE FA-2MATCHLINE SEE FA-4MATCHLINE SEE FA-2MATCHLINE SEE FA-5MATCHLINE SEE FA-3MATCHLINE SEE FA-5 MATCHLINE SEE FA-4 N.I.CN.I.CFA2NOTIFIERENGINEERED SYSTEMS COMPANY, INCENTERPRISESFA-2SCALE: 1/8" = 1'-0"04'8'12'FIRE ALARM SYSTEM PARTIAL FLOOR PLAN1/8"=1'-0"1DEVICE LEGEND WIRE LEGENDKEY PLANFLOOR & DECOR 79315 HIGHWAY 111 LA QUINTA, CA 92253NOTES RTSASBUILT02-18-20 BREAKROOM109MEN'S105CORR. 1108STOCKROOM103WOMEN'S106JANITOR'SROOM107SIGNROOM117DATAROOM116DESIGNBUILDROOM118MONITORAOMAOM AOMRTSRTSRTSNNNNNNNNNNNNNNNNNNLLLLLLLMATCHLINE SEE FA-3MATCHLINE SEE FA-2 MATCHLINE SEE FA-5MATCHLINE SEE FA-3MATCHLINE SEE FA-2MATCHLINE SEE FA-5AOMNNNN15121114121114121114MONITOR CEMOFFICE115TRAININGROOM110 VAULT112CORR. 2111CASHROOM113ASSIST.MGR.114BREAKROOM109MEN'S105CORR. 1108GF.5STOCKROOM103FE.5ED.9SALES102DC.9D.2D.5C.5CMONITOR B.5DESIGNCENTER120WOMEN'S106JANITOR'SROOM107SIGNROOM117DATAROOM116G.5HDESIGNBUILDROOM118 CPU104VESTIBULE101 BA.2U/CSAFEMONITOR AOM RTS AOM AOM AOM AOMAOM AOMAOMAOMRTS RTS RTS RTS RTS RTS RTS18 RTS NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNL L L LLLLL L LLLL LL L L LL LLL LA,PA,PA,PA,PA,P MATCHLINE SEE FA-3 MATCHLINE SEE FA-2 MATCHLINE SEE FA-5 MATCHLINE SEE FA-4 MATCHLINE SEE FA-5MATCHLINE SEE FA-3MATCHLINE SEE FA-4MATCHLINE SEE FA-2MATCHLINE SEE FA-3 MATCHLINE SEE FA-2MATCHLINE SEE FA-4MATCHLINE SEE FA-2MATCHLINE SEE FA-5MATCHLINE SEE FA-3MATCHLINE SEE FA-5 MATCHLINE SEE FA-4 N.I.CN.I.CFA3NOTIFIERENGINEERED SYSTEMS COMPANY, INCENTERPRISESFA-3SCALE: 1/8" = 1'-0"04'8'12'FIRE ALARM SYSTEM PARTIAL FLOOR PLAN1/8"=1'-0"1FLOOR & DECOR 79315 HIGHWAY 111 LA QUINTA, CA 92253 DEVICE LEGEND WIRE LEGENDKEY PLANRTSNOTESASBUILT02-18-20 SALES102DESIGNCENTER120VESTIBULE101AOMAOMRTSNNNNNLLLLLA,PA,PA,PMATCHLINE SEE FA-5 MATCHLINE SEE FA-4 MATCHLINE SEE FA-2MATCHLINE SEE FA-2MATCHLINE SEE FA-5 MATCHLINE SEE FA-4N.I.CMULLLLLNNNNN12111412116981719771819RTS14MONITOR CEMOFFICE115TRAININGROOM110VAULT112CORR. 2111CASHROOM113ASSIST.MGR.114BREAKROOM109MEN'S105CORR. 1108GF.5STOCKROOM103FE.5ED.9SALES102DC.9D.2D.5C.5CMONITOR B.5DESIGNCENTER120WOMEN'S106JANITOR'SROOM107SIGNROOM117DATAROOM116G.5HDESIGNBUILDROOM118 CPU104VESTIBULE101BA.2U/CSAFE MONITOR AOMRTS AOMAOM AOM AOM AOMAOM AOM AOMRTS RTS RTS RTS RTS RTS RTS18 RTS NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNLL LLLL LL LLL L LLLL LLL LLL LA,PA,PA,PA,PA,PMATCHLINE SEE FA-3 MATCHLINE SEE FA-2 MATCHLINE SEE FA-5 MATCHLINE SEE FA-4 MATCHLINE SEE FA-5MATCHLINE SEE FA-3MATCHLINE SEE FA-4MATCHLINE SEE FA-2MATCHLINE SEE FA-3 MATCHLINE SEE FA-2MATCHLINE SEE FA-4MATCHLINE SEE FA-2MATCHLINE SEE FA-5MATCHLINE SEE FA-3MATCHLINE SEE FA-5 MATCHLINE SEE FA-4 N.I.CN.I.CFA4NOTIFIERENGINEERED SYSTEMS COMPANY, INCENTERPRISESFA-4SCALE: 1/8" = 1'-0"04'8'12'FIRE ALARM SYSTEM PARTIAL FLOOR PLAN1/8"=1'-0"1FLOOR & DECOR 79315 HIGHWAY 111 LA QUINTA, CA 92253 DEVICE LEGEND WIRE LEGENDKEY PLANRTSNOTESASBUILT02-18-20 MONITORCPU104AOMRTSAOMRTSNNNNNNNNNNNNNLLLLLLMATCHLINE SEE FA-5MATCHLINE SEE FA-4 MATCHLINE SEE FA-5MATCHLINE SEE FA-3MATCHLINE SEE FA-5MATCHLINE SEE FA-3MATCHLINE SEE FA-5MATCHLINE SEE FA-4NNNNN 12111414121113MONITOR CEMOFFICE115TRAININGROOM110VAULT112CORR. 2111CASHROOM113ASSIST.MGR.114BREAKROOM109MEN'S105CORR. 1108GF.5STOCKROOM103FE.5ED.9SALES102DC.9D.2D.5C.5CMONITOR B.5DESIGNCENTER120WOMEN'S106JANITOR'SROOM107SIGNROOM117DATAROOM116G.5HDESIGNBUILDROOM118CPU104VESTIBULE101BA.2U/CSAFE MONITOR AOMRTS AOMAOMAOMAOM AOMAOM AOM AOM RTS RTS RTS RTS RTS RTS RTS18 RTS NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNLLLL LLLLL LL L LLLL LL LLLL LA,PA,PA,PA,PA,PMATCHLINE SEE FA-3 MATCHLINE SEE FA-2 MATCHLINE SEE FA-5 MATCHLINE SEE FA-4 MATCHLINE SEE FA-5MATCHLINE SEE FA-3MATCHLINE SEE FA-4MATCHLINE SEE FA-2MATCHLINE SEE FA-3 MATCHLINE SEE FA-2MATCHLINE SEE FA-4MATCHLINE SEE FA-2MATCHLINE SEE FA-5MATCHLINE SEE FA-3MATCHLINE SEE FA-5 MATCHLINE SEE FA-4 N.I.CN.I.CFA2NOTIFIERENGINEERED SYSTEMS COMPANY, INCENTERPRISESFA-5SCALE: 1/8" = 1'-0"04'8'12'FIRE ALARM SYSTEM PARTIAL FLOOR PLAN1/8"=1'-0"1FLOOR & DECOR 79315 HIGHWAY 111 LA QUINTA, CA 92253 DEVICE LEGEND WIRE LEGENDKEY PLANRTSNOTESASBUILT02-18-20 NOTIFIERENGINEERED SYSTEMS COMPANY, INCENTERPRISESFA-6FLOOR & DECOR 79315 HIGHWAY 111 LA QUINTA, CA 92253SILENT KNIGHT 6700 FIRE ALARM PANEL WIRING DMP CellComSLCFWIRELESS COMMUNICATOR6855 ANNUNCIATORTB5TB2TB4TB1TB2TB4TYPICAL FCPS- REMOTE POWER SUPPLYNOTIFICATION APPLIANCE WIRING - TYPICALLOOP 1 ADDRESSABLE DETECTORSLOOP 1 ADDRESSABLE MODULESZONINGASBUILT02-18-20 NOTIFIERENGINEERED SYSTEMS COMPANY, INCENTERPRISESFA-7FLOOR & DECOR 79315 HIGHWAY 111 LA QUINTA, CA 92253ASBUILT02-18-20 RISER DIAGRAMNNLA,PRTSRTSRTSRTSRTSAOMNNNNNRTSRTSRTSRTSNNNNNNOTIFIERENGINEERED SYSTEMS COMPANY, INCENTERPRISESFA-8FIRESTOPPING DETAILWall Assembly --Studs --Gypsum Board* --The F Rating of the firestop system is equal to the fire rating of the wall assembly.Through-Penetrants --Steel Pipe --Iron Pipe --Conduit --Copper Tubing --Copper Pipe --Fill, Void or Cavity Material* -- Sealant -- HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INCTYPICAL DEVICE ELEVATIONSSMOKE DETECTORPULL STATIONPUSH INPULL DOWN135910764 RELAY MODULE28FLOOR & DECOR 79315 HIGHWAY 111 LA QUINTA, CA 92253 FACP CABINET DIMREMOTE ANNUNCIATORPOWER SUPPLY BACKBOX”” FIRESYSTEM SENSOR P2RK WALL MOUNTED WP HORN STROBESYSTEM SENSOR - L SERIES CEILING & WALL MOUNTED STROBES& HORN/STROBESASBUILT02-18-20 79485 Calle Tampico La Quinta, CA 92253 Main Number (760) 777-7158 Inspection Number  (760)777-7131 CITY OF LA QUINTA FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79315 HIGHWAY 111 PERMIT# : FA2019-0010 DATE ISSUED: 9/3/2019 DESCRIPTION: FLOOR & DECOR / BCOM2019-0016 / FIRE ALARM SYSTEM CONTRACTOR: HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: 79485 Calle Tampico La Quinta, CA 92253 Main Number (760) 777-7158 Inspection Number  (760)777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. The inspection hotline for the City of La Quinta is (760)777-7131 B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.