Loading...
FA2020-0004ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT PASTION INDUSTRIES 45-450 TOWNE STREET INDIO CA 92201 JASON@PASTIONINDU STRIES.COM BILL TO PASTION INDUSTRIES 45-450 TOWNE STREET INDIO CA 92201 JASON@PASTIONINDU STRIES.COM CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE ARMANDO MAGALLON 5/28/2020 5/28/2020 DUE TO SCOPE OF WORK FEES HAVE BEEN REDUCES TO 1 HOUR FOR PLAN CHECK AND 1 HOUR FOR INSPECTION. I HAVE REMOVED THE FIRE ALARM FEE AND HAVE ADDED 2 HOURS OF STAFF TIME @ 161 PER HOUR. FEE REDUCTION PER KOHL. CONDITIONS Description: PIERCE GROUP / SF REAL ESTATE OFFICE / FIRE ALARM Type: FIRE ALARM (WEB)Subtype: COMMERCIAL - FIRE ALARM SYSTEM Status: FINALED Applied: 5/28/2020 AMA Parcel No: 770020023 Site Address: 78140 CALLE TAMPICO STE 103 LA QUINTA,CA 92253 Approved: 6/1/2020 KHET Subdivision: PM 27109 Block: Lot: 1 Issued: 6/1/2020 KHET Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 6/2/2020 KHET Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Wednesday, February 15, 2023 2:37:57 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2020-0004 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL CONTRACTOR PASTION INDUSTRIES 45-450 TOWNE STREET INDIO CA 92201 JASON@PASTIONINDU STRIES.COM OWNER PIERCE GROUP CALLE TAMPICO, LLC.78140 CALLE TAMPICO LA QUINTA CA 92253 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FUNCTION TEST KHET 6/2/2020 6/2/2020 APPROVED REMOTE VIDEO INSPECTION FIRE FINAL**KHET 6/2/2020 6/2/2020 APPROVED REMOTE VIDEO INSPECTION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE STAFF - PER HOUR 101-0000-42420 2 $322.00 $322.00 5/28/20 WEB5290 CREDIT PASTION INDUSTRIES ECON Total Paid for FIRE FEES: $322.00 $322.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 5/28/20 WEB5290 CREDIT PASTION INDUSTRIES ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 5/28/20 WEB5290 CREDIT PASTION INDUSTRIES ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$337.00 $337.00 Printed: Wednesday, February 15, 2023 2:37:57 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2020-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/1/2020 KOHL HETRICK FA2020-0004 - APPROVED PLANS and SPECS.pdf FA2020-0004 - APPROVED PLANS and SPECS.pdf 1 DOC 6/1/2020 KOHL HETRICK FA2020-0004 - COA and JOB CARD.pdf FA2020-0004 - COA and JOB CARD.pdf 1 BOND INFORMATION 1ST PERMIT TECH (1 DAY) ARMANDO MAGALLON 5/28/2020 5/29/2020 5/28/2020 COMPLETE FEES PAID AND PLANS AND CUT SHEETS UPLOADED 1ST FIRE - ETRAKIT (2 WK) KOHL HETRICK 5/28/2020 6/11/2020 6/1/2020 APPROVED SEE ATTACHMENTS Printed: Wednesday, February 15, 2023 2:37:57 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2020-0004 FA2020-0004 PROJECT TITLE:SHEET TITLE:JOB NO.:DATE:SCALE:DRAWN BY:CHECKED BY:SHEET NO.:SHEETAS NOTEDDPG FA - 0202 of 03REF. NO.:NO.INIT.REVISIONSDATEDESCRIPTIONNESW78140 Calle TampicoLa Quinta, CA 92253BATTERY CALCULATIONS FOR FACP - BOSCH FPD-7024MODELSTANDBYEXTENDEDALARMEXTENDEDQTY.MANUFACTURERNUMBERDESCRIPTIONCURRENTSTANDBYCURRENTALARM1BoschFPD-7024Fire Alarm Control Panel0.200000.200000.380000.380001BoschFPE-7039MUX Expander0.190000.190000.190000.190001BoschFMR-7036Remote Annunciator0.080000.080000.100000.100001BoschD7050Smoke Detector0.000550.000550.000550.000558BoschD7044Input Module0.000550.004400.000550.004401BoschD7052Dual Input Module0.000550.000550.000550.00055Panel Voltage:24VDCTotal Standby:0.4755Total Alarm:0.6755Battery Voltage:12VDCHours in Standby:24Minutes in Alarm:5Battery Capacity:18Amp HoursStandby AH:11.4120Alarm AH:0.0563De-Rating Factor:20%Number of Batteries:2Total Capacity Used:11.4683Total Battery Capacity:18Amp Hours @ Panel VoltageBattery Capacity:18.0000De-Rated Battery Capacity:14.4000Spare Amp Hours:2.9317Spare Amp Hours Percentage:20.36%BATTERY CALCULATIONS FOR RADIO COMMUNICATOR - AES 7788FMODELSTANDBYEXTENDEDALARMEXTENDEDQTY.MANUFACTURERNUMBERDESCRIPTIONCURRENTSTANDBYCURRENTALARM1AES7788FRadio Communicator0.150000.150001.200001.20000Panel Voltage:12VDCTotal Standby:0.1500Total Alarm:1.2000Battery Voltage:12VDCHours in Standby:24Minutes in Alarm:5Battery Capacity:7Amp HoursStandby AH:3.6000Alarm AH:0.1000De-Rating Factor:20%Number of Batteries:1Total Capacity Used:3.7000Total Battery Capacity:7Amp Hours @ Panel VoltageBattery Capacity:7.0000De-Rated Battery Capacity:5.6000Spare Amp Hours:1.9000Spare Amp Hours Percentage:33.93%FIRST FLOORFIRE ALARMSYSTEMGRUNDER DEVELOPMENTPASTION INDUSTRIES INC.45-450 Town StreetIndio, CA 92201 State Contractors License C-10 # 736561Tel.(760) 345-7088 FAX (760) 347-60380DPG05/18/2020FOR APPROVALJ-5887J-588705/18/2020RESTROOMRESTROOMOFFICE #1OFFICE #2BREAK ROOMCONFERENCE ROOMCONFERENCE ROOMOFFICE #1OFFICE #2OFFICE #3OFFICE #4OPEN OFFICEOFFICE #1OFFICE #1OFFICE #2OPEN OFFICESUITE 101SUITE 102SUITE 103SUITE 104SUITE 105WIRE DESCRIPTION TABLEWIRE IDAWGCONDUCTOR TYPETYPEDESCRIPTIONTYPECIRCUIT ORIGIND18Solid18/2 FPLRInitiatingSLCFACPU14Stranded2#14 THWNInitiating UndergroundSLCFACPA14Solid14/2 FPLRIndicatingNACPower SupplyK18Solid18/4 FPLRAnnunciatorDATAFACPDefinitions:FPLPower-limited fire alarm cable listed as being suitable for general-purpose fire alarm use,with the exception of risers, ducts, plenums, and other space used for environmental airand shall also be listed as being resistant to the spread of fire.FPLRPower-limited fire alarm riser cable listed as being suitable for use in a vertical run in ashaft or from floor to floor and shall also be listed as having fire-resistant characteristicscapable of preventing the carying of fire from floor to floor.THHNThermoplastic High Heat Resistant Nylon Coated Cable.THWNThermoplastic Heat and Water Resistant Nylon Coated Cable.Cable within seven (7) feet of finished floor must be protected from physical damage.Cable above seven (7) feet may be exposed, and supported, unless AHJ requires otherwise.Use Type "THWN" For Wet/ Damp Locations.120 VACFIRE BELLBY OTHERSZ9Z18N1-3DK,DAFIRE ALARM SYSTEM SEQUENCE OF OPERATIONSREACTIONACTIONPIVDUCTSMOKEWATERFLOWTAMPERSMOKEPOWERCOMMSYSTEMDETECTORSWITCHSWITCHDETECTORFAILURETROUBLETROUBLEANNUNCIATE AT FIRE ALARM CONTROL PANELXXXXXXXANNUNCIATE AT REMOTE ANNUNCIATORXXXXXXXACTIVATE NOTIFICATION ALARM DEVICESXXACTIVATE 120VAC FIRE BELLXACTIVATE HVAC SHUTDOWNXACTIVATE CENTRAL STATION CONNECTION - ALARMXXACTIVATE CENTRAL STATION CONNECTION - SUPERVISORYXXACTIVATE CENTRAL STATION CONNECTION - TROUBLEXXXZ32Z19PIVU2A2AN1-1N1-2AAAAAN1-4N1-6N1-7VOLTAGE DROP CALCULATIONS FOR NOTIFICATION CIRCUIT: N1Voltage:20.4VDCTemperature:167Fahrenheit =75.0CentigradeWire Gauge (AWG):14AWG =4110Circ Mils =0.00319Ohms/ FootNUMBERCONDUCTOROFLENGTHTOTALAWGCIRCULAROHMSVOLTAGEPERCENTDEVICES(FEET)AMPERESSIZEMILSPER FOOTDROPDROP62700.58201441100.003191.0024.91%Total Voltage Drop1.002VoltsTotal Percentage Voltage Drop in Circuit4.91PercentAN1-5NOTIFICATION APPLIANCE CIRCUIT (NAC) LISTZONE# OFWIREPATHWAYPATHWAYPREFIX#DEVICESDEVICE TYPELOCATIONCIRCUIT ORIGINIDCLASSSURVIVABILITYN17Horn/StrobeFirst FloorPower SupplyAB0N25Horn/StrobeSecond FloorPower SupplyAB0N311Horn/StrobeSecond FloorPower SupplyAB0N412Horn/StrobeSecond FloorPower SupplyAB0SIGNALING LINE CIRCUIT (SLC) LISTPOINTWIREPATHWAYPATHWAYPREFIX#DEVICE TYPELOCATIONCIRCUIT ORIGINIDCLASSSURVIVABILITYZ9Smoke DetectorAt FACPFACPDB0Z10- -- -FACP- -- -- -Z11- -- -FACP- -- -- -Z12- -- -FACP- -- -- -Z13- -- -FACP- -- -- -Z14- -- -FACP- -- -- -Z15- -- -FACP- -- -- -Z16- -- -FACP- -- -- -Z17- -- -FACP- -- -- -Z18Waterflow Switch1st FloorFACPDB0Z19PIV Tamper SwitchOutsideFACPUB0Z20Duct DetectorOn RoofFACPDB0Z21- -- -FACP- -- -- -Z22- -- -FACP- -- -- -Z23- -- -FACP- -- -- -Z24Duct DetectorOn RoofFACPDB0Z25Duct DetectorOn RoofFACPDB0Z26Duct DetectorOn RoofFACPDB0Z27Duct DetectorOn RoofFACPDB0Z28- -- -FACP- -- -- -Z29Duct DetectorOn RoofFACPDB0Z30Duct DetectorOn RoofFACPDB0Z31- -- -FACP- -- -- -Z32Communication TroubleAt FACPFACPDB0FIRST FLOOR PLANSCALE: 1/8" = 1'PFACPAESFAAWC115cdAIMDIMVSPS30cd30cdBATTERY CALCULATIONS FOR POWER SUPPLY - BOSCH FPP-RNAC-8A-4CMODELSTANDBYEXTENDEDALARMEXTENDEDQTY.MANUFACTURERNUMBERDESCRIPTIONCURRENTSTANDBYCURRENTALARM1BoschFPP-RNAC-8A-4CPower Supply0.150000.150000.150000.150004System SensorSCRStrobe @ 30cd Ceiling0.000000.000000.094000.3760015System SensorPC2RHorn/Strobe @ 15cd Ceiling0.000000.000000.079001.185009System SensorPC2RHorn/Strobe @ 30cd Ceiling0.000000.000000.107000.963003System SensorPC2RHorn/Strobe @ 115cd Ceiling0.000000.000000.218000.654004System SensorHRLHorn0.000000.000000.044000.17600Panel Voltage:24VDCTotal Standby:0.1500Total Alarm:3.5040Battery Voltage:12VDCHours in Standby:24Minutes in Alarm:5Battery Capacity:7Amp HoursStandby AH:3.6000Alarm AH:0.2920De-Rating Factor:20%Number of Batteries:2Total Capacity Used:3.8920Total Battery Capacity:7Amp Hours @ Panel VoltageBattery Capacity:7.0000De-Rated Battery Capacity:5.6000Spare Amp Hours:1.7080Spare Amp Hours Percentage:24.40%HHHHAREA OF WORKEEEEEEEEEEEEEEEE PROJECT TITLE:0DPG05/18/2020FOR APPROVALSHEET TITLE:JOB NO.:DATE:SCALE:DRAWN BY:CHECKED BY:SHEET NO.:SHEETAS NOTEDDPG FA - 0303 of 03REF. NO.:J-5887NO.INIT.REVISIONSDATEDESCRIPTIONJ-588705/18/2020SECOND FLOORNESWSECOND FLOOR PLANSCALE: 1/8" = 1'78140 Calle TampicoLa Quinta, CA 92253GRUNDER DEVELOPMENTFIRE ALARMSYSTEMPASTION INDUSTRIES INC.45-450 Town StreetIndio, CA 92201 State Contractors License C-10 # 736561Tel.(760) 345-7088 FAX (760) 347-6038CONFERENCE ROOM JOHNS OFFICETBDCT OFFICEFILE ROOMMENSRESTROOMWOMENSRESTROOMCT OFFICECT OFFICEDR.OFFICELVN OFFICESTORAGEMHSS OFFICEMED ROOMCOPIER ROOMMEDIUM GROUP ROOMCOMMUNITY PARTNER ROOMMEDIUM GROUP ROOMTELE PSYCHIATRYCOMMUNITY PARNER ROOMSMALL GROUP ROOMINTERVIEW ROOMSR. PEER OFFICESR. PEER OFFICEINTERVIEW ROOMJANITOR CLOSETFAMILY INT. ROOMPEER SPECIALIST ROOMPEER SPECIALISTOFFICESTORAGEPEER SPECIALISTOFFICEPEER SPECIALISTOFFICEI.T. ROOMELEVATORROOMSMALL CLASSROOMSMALL CLASSROOMCOMMUNITY PARNER ROOMBREAK ROOMACTIVITY ROOMCLIENT LOUNGETO FACPA2AAA2ADDDDDDDAC15cdC30cdC15cdC15cdC115cdN2-1N2-2N2-3N2-4N2-5AIMSAIMSAIMSON ROOFON ROOFON ROOFAIMSAIMSAIMSON ROOFON ROOFON ROOFAIMSON ROOFC15cdC115cdC15cdC15cdC15cdC15cdC15cdC15cdC15cdC15cdC15cdC15cdC15cdZ20Z24Z25Z26Z27Z29Z30N3-1N3-2N3-3N3-4N3-5N3-6N3-7N3-8N3-9N3-11N4-1N4-2N4-3N4-4N4-5N4-6N4-7N4-8N4-9N4-10N4-12N3-10N4-11C30cdC30cdC30cdC30cdC30cdC30cdC30cdC30cd30cd30cdVOLTAGE DROP CALCULATIONS FOR NOTIFICATION CIRCUIT: N2Voltage:20.4VDCTemperature:167Fahrenheit =75.0CentigradeWire Gauge (AWG):14AWG =4110Circ Mils =0.00319Ohms/ FootNUMBERCONDUCTOROFLENGTHTOTALAWGCIRCULAROHMSVOLTAGEPERCENTDEVICES(FEET)AMPERESSIZEMILSPER FOOTDROPDROP52600.53401441100.003190.8854.34%Total Voltage Drop0.885VoltsTotal Percentage Voltage Drop in Circuit4.34PercentVOLTAGE DROP CALCULATIONS FOR NOTIFICATION CIRCUIT: N3Voltage:20.4VDCTemperature:167Fahrenheit =75.0CentigradeWire Gauge (AWG):14AWG =4110Circ Mils =0.00319Ohms/ FootNUMBERCONDUCTOROFLENGTHTOTALAWGCIRCULAROHMSVOLTAGEPERCENTDEVICES(FEET)AMPERESSIZEMILSPER FOOTDROPDROP113101.12201441100.003192.21710.87%Total Voltage Drop2.217VoltsTotal Percentage Voltage Drop in Circuit10.87PercentVOLTAGE DROP CALCULATIONS FOR NOTIFICATION CIRCUIT: N4Voltage:20.4VDCTemperature:167Fahrenheit =75.0CentigradeWire Gauge (AWG):14AWG =4110Circ Mils =0.00319Ohms/ FootNUMBERCONDUCTOROFLENGTHTOTALAWGCIRCULAROHMSVOLTAGEPERCENTDEVICES(FEET)AMPERESSIZEMILSPER FOOTDROPDROP123151.11601441100.003192.24110.99%Total Voltage Drop2.241VoltsTotal Percentage Voltage Drop in Circuit10.99PercentEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE EEEEEEEEE Submittal Package for: Grunder Development 78140 Calle Tampico La Quinta, CA 92253 Pastion Industries 45-450 Towne Street Indio, CA 92201 Contains Cutsheets and CSFM Listings for: EXISTING Fire Alarm Control Panel EXISTING Power Supply Horn Fire Alarm Systems | FPD‑7024 Fire Alarm Control Panels The FPD‑7024 Fire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. They are listed by UL for central station, local, auxiliary, and remote station systems. The FPD‑7024 FACPs support four on‑board initiating zones that can be expanded to eight using the FPC-7034. Each initiating zone supports two‑wire and four‑wire detectors configurable as Class A , Style D or Class B, Style B loops. Each zone can support up to 20 two‑wire detectors, or any number of four‑wire detectors depending on available power. Each FACP has a built‑in digital fire alarm communicator transmitter (DACT). Enhance the FPD‑7024 conventional system features by adding a D7039 Multiplex Expansion Module. Adding a D7039 Multiplex Expansion Module to the FPD‑7024 turns the conventional FACP into an addressable FACP. The D7039 adds up to 247 addressable points to the base system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases the number of programmable relay outputs from 19 to 59 and expands system users to 100. Functions Notification Appliance Circuits (NACs) Two Class A, Style Z or Class B, Style Y NACs provide up to 4 A of regulated 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, California March, steady, pulsed, and synchronized output for either Wheelock or System Sensor notification appliances. User Interface A viewing port in the locked control panel enclosure door shows the system status light‑emitting diodes (LEDs) and liquid‑crystal display (LCD) while maintaining system keypad security. Unlocking the enclosure door provides access to the system controls for silencing off‑normal conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all FMR‑7033 LCD Keypads connected to the system. Organized Event Display Sorts alarm, trouble, and supervisory events into categories and allows scrolling through specific events. History Buffer The system stores events in a 99‑event history buffer. Note The number of events that can be stored in the history buffer increases to 499 with the FPD‑7024 Fire Alarm Control Panels ▶Four initiating zones (expandable to eight); up to 20 two‑wire smoke detectors per zone ▶Built‑in DACT ▶Two notification appliance circuits (NACs) on board with a shared internal regulated 24 VFWR, 4 A NAC power supply ▶Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module ▶Programmable through front panel interface, remote FMR‑7033 Liquid‑crystal Display (LCD) Keypads, remote programming software (RPS), or DX4010V2 or DX4020 www.boschsecurity.com 2 | FPD‑7024 Fire Alarm Control Panels addition of a D7039 Multiplex Expansion Module. Central Station Reporting The FPD-7024 FACPs send reports to two telephone numbers (or IP addresses with a DX4020 Network Interface Module installed) with full single, double, and backup reporting. They communicate in BFSK, SIA, Contact ID, Modem IIIa2, and 4/2 and 3/1 Tone Bursts. Dirty Smoke Detector Monitoring All on‑board zones and FPC‑7034 zones are continuously monitored for smoke detectors signaling a dirty condition using the Bosch Chamber Check feature and CleanMe protocol. If a detector's smoke chamber is dirty, the detector sends a CleanMe signal on the two‑wire loop or a dirty detector signal on the addressable loop. The control panel annunciates that there is a dirty detector on the loop or the address. The Chamber Check feature signals a dirty smoke chamber using the LED on the detector head. Accessories The FPD‑7024 enclosure has space for additional accessory modules and two D1218 (18 Ah) batteries or two D126 (7 Ah) batteries. Certifications and Approvals Region Certification USA UL UOXX: Control Unit Accessories, System (ANSI/UL 864) FM CSFM 7165-1615:0227 FIRE ALARM CONTROL UNIT (COMMERCIAL) FCC ESVAL04B7024 FDNY- CoA #6024 Brazil ANATEL 0383-11-1855 Installation/Configuration Notes Compatible Products The following products are compatible with the FPD‑7024 FACP: Category Product ID Product Description Batteries and D126 12 V, 7 Ah battery Power Supplies D1218 12 V, 18 Ah battery D7038 Remote NAC power supply Detectors For two‑wire detector compatibility, refer to FPD‑7024 Smoke Detector Compatibility List Technogram (P/N: F01U010790) Category Product ID Product Description Keypads and Annunciators D7030X Eight‑point LED annunciator (eight red) D7030X‑S2 Eight‑point LED annunciator (two yellow, six red) D7030X‑S8 Eight‑point LED annunciator (eight yellow) D7032 Eight‑point LED annunciator expander (eight red) FMR‑7033 LCD fire system keypad FMR‑7036 LCD annunciator Modules D132B Smoke detector reversing relay module D184A Local energy kit D185 Reversing polarity module D275 EOL power supervision module FPC‑7034 Four‑point expander D7039 Multiplex expansion module Option Bus Devices D7035 Octal relay module D7035B Octal relay module in box DX4010V2 USB/serial interface module DX4020 Network interface module NAC Devices Refer to FPD‑7024 Device Compatibility List Technogram (P/N: F01U010791) The following additional products are compatible with the FPD‑7024 Addressable FACPs: Category Product ID Product Description Detector Heads and Bases D7050 Addressable Photoelectric Smoke Detector Head D7050TH Addressable Photoelectric Smoke and Heat Detector Head D7050‑B6 Detector Base Modules D7042 Multiplex eight‑input remote module D7042B Multiplex eight‑input remote module in box D7044 Multiplex single‑input module D7044M Mini multiplex single‑input module D7048 Multiplex octal driver D7048B Multiplex octal driver in box D7052 Multiplex dual‑input module D7053 Multiplex input‑output module Pull Stations FMM‑7045 Single‑action manual station FMM‑7045‑D Double‑action manual station FPD‑7024 Fire Alarm Control Panels | 3 Parts Included Quant. Component 1 FPD‑7024 board in a static‑resistant bag 1 Enclosure (P/N: 30897) 1 Lock set with two #1358 (D102) keys (P/N: F01U009775) 1 Transformer (P/N: F01U008702) 6 2.21 kΩ end‑of‑line (EOL) resistors (P/N: 25899 or 4998113202) 1 Hardware pack 1 Literature pack Note For the FPD‑7024 to be addressable, a D7039 Multiplex Expansion Module must be installed. The D7039 is purchased separately. Technical Specifications Electrical Current (alarm): 380 mA Current (standby): 200 mA Power (primary): 120 VAC, 1.2 A maximum, 60 Hz or 240 VAC, 0.75 A maximum, 50 Hz Environmental Environment:Indoor, dry Relative Humidity: Up to 95%, non-condensing Temperature (operating): +32°F to +120°F (0°C to +49°C) Mechanical Properties Color:Red Dimensions (HxWxD): 20.8 in. x 15 in. x 4.3 in. (52.8 cm x 38.1 cm x 10.9 cm) Material:Cold-rolled steel Base: 18 gauge (1.2 mm) Cover: 19 gauge (1.1 mm) Indicating Device Circuits (IDC) Current:44 mA maximum per loop Line resistance:150 Ω Voltage:24 VDC nominal Outputs NAC:24 VDC nominal, 4 A maximum On-board Relays: Three Form C contacts rated at 5 A, 28 VDC Off-board Relays: Up to two D7035 Octal Relay Modules with each providing eight Form C relay outputs; contacts rated at 5 A, 28 VDC In an addressable system, up to 20 D7053 Multiplex Input-Output Modules are allowed per bus for a total of 40 Trademarks Trademark names are used throughout this document. In most cases, these designations are claimed as trademarks or registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc. uses the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringing the trademark. Chamber Check is a registered trademark of Bosch Security Systems, Inc. in the United States. CleanMe is a registered trademark of GE Interlogix in the United States and/or other countries. Wheelock is a trademark of Cooper Wheelock, Inc. System Sensor is a registered trademark of System Sensor, a brand of Honeywell International, Inc. in the United States and/or other countries. Ordering Information FPD-7024 FACP Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone FPD-7024 FPD-7024-LC FACP without Enclosure and Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone FPD-7024-LC FPD-7024-LT FACP without Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone. Available only in Latin America. FPD-7024-LT www.boschsecurity.com 4 | FPD‑7024 Fire Alarm Control Panels Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.asia Represented by © Bosch Security Systems Inc. 2011 | Data subject to change without notice T3761282827 | Cur: en-US, V12, 22 Mar 2011 Fire Alarm Systems | FPP‑RNAC‑8A‑4C Remote Notification Appliance Circuit (RNAC) Power Supply Use the FPP‑RNAC‑8A‑4C power supply to add four additional notification appliance circuits to a fire alarm control panel (when connected via the option bus), or as a NAC power supply for fire-protective signaling systems (when connected directly to the NAC output). The additional notification appliance circuits can be NFPA 72, Class B (Style Y) or Class A (Style Z). This regulated power supply provides up to 8 A of power that is used to operate both continuous and intermittent loads. This 8 A of power can be distributed through the four output circuits and auxiliary power circuit. The FPP‑RNAC‑8A‑4C power supply is UL Listed for use in commercial fire alarm applications. Functions Compatible Control Panel Connections The FPP‑RNAC‑8A‑4C power supply is compatible with any UL Listed control panel that uses reverse polarity supervised notification outputs with 12 VDC or 24 VDC regulated outputs. It is also compatible with the following Bosch Control Panels: •D7022 Two‑zone Conventional FACP•D8024 and D10024A Analog FACPs -For the D7022 conventional panel and the D8024 and D10024A analog panels, the FPP‑RNAC‑8A‑4C connects through a NAC circuit. No option bus connection is necessary.•D7024 Four‑zone Addressable FACP•DS9400i Four‑zone FACP•DS9400M AddressiFire FACP-Connect up to two FPP‑RNAC‑8A‑4C power supplies to a D7024, DS9400i, or DS9400M Control Panel. The control panel can individually control each of the four NAC outputs for each FPP‑RNAC‑8A‑4C power supply. Only the four NAC outputs of a single FPP‑RNAC‑8A‑4C will be synchronized.•FPD‑7024 or FPA‑1000‑UL FACP-Connect up to four FPP‑RNAC‑8A‑4C power supplies to an FPD‑7024 or an FPA‑1000‑UL control panel. Each RNAC’s four NAC outputs will be synchronized and can be individually controlled for a total of 16 synchronized circuits. NAC Output Patterns The NAC circuits can be set to produce the following output patterns: •Steady•Temporal Code 3•Pulsed•California March•Wheelock Synch•Gentex Synch•System Sensor Synch FPP‑RNAC‑8A‑4C Remote Notification Appliance Circuit (RNAC) Power Supply ▶8 A of power ▶Fully supervised outputs ▶Configurable for NAC output or constant auxiliary power ▶Regulated 24 VDC output (nominal) with over‑current protection ▶Built‑in NAC patterns ▶Four Class B (Style Y) or Class A (Style Z) circuits ▶Form C trouble relay ▶Status indicator on control panel when connected to the option bus. ▶Ground fault indication ▶Charger control monitor www.boschsecurity.com 2 | FPP‑RNAC‑8A‑4C Remote Notification Appliance Circuit (RNAC) Power Supply Status Displays There are eight local status display LEDs on the FPP‑RNAC‑8A‑4C's printed circuit board that show the following conditions: •AC OK•System Trouble•Ground Fault•Input Active•Trouble Output 1, 2, 3, and 4 DIP Switch Settings If connected to the fire alarm control panel’s option bus, the FPP‑RNAC‑8A‑4C needs its own option bus address. Set this address through the DIP switches. Set the DIP switches to choose: •NAC or power supply output•NAC Input Variable option•AC Delay Time Certifications and Approvals Region Certification USA UL UOXX: Control Unit Accessories, System (ANSI/UL 864, 9th edition) and UTRZ: Power-supply Units (UL 1481) FM CSFM 7300-1615:228 FDNY- CoA 6034 Installation/Configuration Notes Compatible Products The following products are compatible with the FPP‑RNAC‑8A‑4C RNAC Power Supply: Category Product ID Product Description Batteries D126 12 V, 7 Ah battery D1218*12 V, 18 Ah battery D1224**12 V, 24 Ah battery D1238**12 V, 38 Ah battery *Up to two 18 Ah batteries fit in the enclo- sure **Requires BATB-40 Battery Box Magnetic Door Holders D370B Brass‑Plated Wall‑Mount D370C Chrome‑Plated Wall‑Mount D371B Brass‑Plated Floor‑Mount D371C Chrome‑Plated Floor‑Mount Category Product ID Product Description Four-wire Smoke Detectors Refer to Technogram (P/N: F01U010790) NAC Devices Refer to Technogram (P/N: F01U010791) Wiring All wiring is connected to the power supply board by lift‑gate terminals that can accept up to 12 AWG (2.3 mm) wire. Parts Included Quant.Component 1 FPP‑RNAC‑8A‑4C board 1 AE4 Large Enclosure (red), vented 4 2.21 kΩ end‑of‑line (EOL) resistors (P/N: F01U034504) For retrofitting applications, allowable EOL values are in the range of 1 kΩ to 20 kΩ 1 Hardware pack Technical Specifications Environmental Considerations Temperature (operating):+32°F to +120°F (0°C to +49°C) Inputs (NAC) Response Time (input to output):10 ms maximum Mechanical Properties Color:Red Dimensions (HxWxD) without door: 20.4 in. x 14.8 in. x 4.1 in. (52 cm x 38 cm x 10.4 cm) Material:cold-rolled steel Base: 18 gauge (1.2 mm) Cover: 19 gauge (1.1 mm) Outputs (auxiliary) Current (output):850 mA maximum Voltage (output):24 VDC (regulated) Outputs (NAC) Output per circuit:2.5 A maximum Output (total):8 A (all NAC and auxiliary outputs) Voltage (output):24 VDC (regulated) Voltage (standby):-24 VDC (regulated) Outputs (trouble and ac trouble relays) Contact Type:Form C Rating (contact):1.5 A at 32 VDC FPP‑RNAC‑8A‑4C Remote Notification Appliance Circuit (RNAC) Power Supply | 3 Power Requirements Current (input):4.5 A maximum (RMS) Power (primary input):120 VAC, 60 Hz or 220 VAC, 50 Hz Voltage (battery):24 VDC nominal Ordering Information FPP‑RNAC‑8A‑4C Remote Notification Appliance Circuit (RNAC) Power Supply Adds four additional notification appliance cir- cuits to a fire alarm control panel FPP-RNAC-8A-4C Accessories D102 Replacement Key Replacement key (#1358) for the D101 lock. D102 www.boschsecurity.com 4 | FPP‑RNAC‑8A‑4C Remote Notification Appliance Circuit (RNAC) Power Supply Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.com Represented by © Bosch Security Systems Inc. 2010 | Data subject to change without notice T2727277451 | Cur: en-US, V7, 4 Jul 2010 Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383, 3057072 Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 × 4 × 17⁄8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411 ⁄16 × 411 ⁄16 × 21 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1,2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 1.91˝ D (143 mm L × 119 mm W × 49 mm D) Compact Wall-Mount Dimensions (including lens)5.26” L x 3.46” W x 1.91” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.25˝ D (143 mm L × 119 mm W × 32 mm D) Compact Horn Dimensions 5.25” L x 3.45” W x 1.25” D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9*Coded High 85 90 90 10*3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Candela Range (15–115 cd) DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Current Draw Data Horn Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86503 • 03/17 L-Series Dimensions Model Description Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT L-Series Ordering Information Notes: All -P models have a plain housing (no “FIRE” marking on cover) All -SP models have “FUEGO” marking on cover All -ALERT models have “ALERT” marking on cover Compact Strobe / Horn Strobe Strobe / Horn Strobe Compact Horn Horn Model Description Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7135-1653:0503 Page 1 of 2 CATEGORY: 7135 -- AUDIBLE DEVICES LISTEE:System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Pete Sennett (630) 762-5362 Fax (203) 484-7309 Email: pete.sennett@honeywell.com DESIGN: System Sensor Indoor 2-wire and *4-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR-2 and *TR-2W CeilingTrim Rings: *TRC-2 and *TRC-2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc July 01, 2019Date Issued:Listing Expires June 30, 2020 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator Listing No. Page 2 of 2 7135-1653:0503 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING:12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee’s Installation Instruction Manual for details. Revision 08-21-2017 dcc July 01, 2019Date Issued:Listing Expires June 30, 2020 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org June 1, 2020 Pastion Industries 45-450 Towne Street Indio, CA 92201 Re: Fire Alarm System TI Plan Review – PIERCE GROUP TI #103 FA2020-0004 / 78140 CALLE TAMPICO #103, LA QUINTA, CA 92253 The fire alarm system TI plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Function Test b) 5-Minute Ring-out / Final Acceptance Testing and Certification 2. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78140 CALLE TAMPICO #103 PERMIT#: FA2020-0004 DATE ISSUED: 6/1/2020 DESCRIPTION: FIRE ALARM TI CONTRACTOR: PASTION INDUSTRIES HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.