Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FA2020-0005
ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT THE STEINHILBER CORPORATION DBA JJJ ENTE PO BOX 463021 ESCONDIDO CA 92046 mario@jjent.com BILL TO THE STEINHILBER CORPORATION DBA JJJ ENTE PO BOX 463021 ESCONDIDO CA 92046 mario@jjent.com CONTRACTOR THE STEINHILBER CORPORATION DBA JJJ ENTE PO BOX 463021 ESCONDIDO CA 92046 mario@jjent.com OWNER Inland American Laquinta Pavilion 79024 HIGHWAY 111 LA QUINTA CA 92253 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE ARMANDO MAGALLON 6/18/2020 6/18/2020 SINCE THIS IS NOT A FULL FIRE ALARM JUST A TI, WE WILL BE CHARGING A REDUCED FEE OF $161 FOR PLAN CHECK AND $161 FOR INSPECTION. PER KOHL CONDITIONS Description: PIEOLOGY / FIRE ALARM TENANT IMPROVEMENT Type: FIRE ALARM (WEB)Subtype: COMMERCIAL - FIRE ALARM SYSTEM Status: FINALED Applied: 6/18/2020 AMA Parcel No: 600390029 Site Address: 79024 HIGHWAY 111 STE 103 LA QUINTA,CA 92253 Approved: 7/6/2020 KHET Subdivision: PM 29351 Block: Lot: 11 Issued: 7/6/2020 KHET Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 9/10/2020 KHET Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Wednesday, February 15, 2023 2:40:43 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2020-0005 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH-WIRE INSPECTION KHET 7/16/2020 7/16/2020 APPROVED REMOTE VIDEO INSPECTION AS-BUILT PLANS REQUIRED AT FINAL FUNCTION TEST KHET 9/10/2020 9/10/2020 APPROVED REMOTE VIDEO INSPECTION FIRE FINAL**KHET 9/10/2020 9/10/2020 APPROVED REMOTE VIDEO INSPECTION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE ALARM SYSTEMS 101-0000-42421 0 $161.00 $161.00 6/22/20 WEB5514 CREDIT THE STEINHILBER CORPORATION DB ECON FIRE ALARM SYSTEMS 101-0000-42421 0 $161.00 $161.00 6/22/20 WEB5514 CREDIT THE STEINHILBER CORPORATION DB ECON Total Paid for FIRE FEES: $322.00 $322.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 6/22/20 WEB5514 CREDIT THE STEINHILBER CORPORATION DB ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/22/20 WEB5514 CREDIT THE STEINHILBER CORPORATION DB ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$337.00 $337.00 Printed: Wednesday, February 15, 2023 2:40:43 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2020-0005 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/22/2020 EtrakitContractor 1ST SUBMITTAL - TI PLAN SET 1ST SUBMITTAL - FIRE ALARM T.I..pdf 1 DOC 6/22/2020 EtrakitContractor 1ST SUBMITTAL -FIRE ALRM DATA SHEETS 1ST SUBMITTAL - DATA SHEETS T.I..pdf 1 DOC 9/8/2020 KAYLI ALFORD FA2020-0005 Asbuilts.pdf FA2020-0005 Asbuilts.pdf 0 DOC 7/6/2020 KOHL HETRICK FA2020-0005 - FIRE ALARM TI - APPROVED PLANS.pdf FA2020-0005 - FIRE ALARM TI - APPROVED PLANS.pdf 1 DOC 7/6/2020 KOHL HETRICK FA2020-0005 - PIEOLOGY - COA and JOB CARD.pdf FA2020-0005 - PIEOLOGY - COA and JOB CARD.pdf 1 DOC 7/16/2020 KOHL HETRICK FA2020-0005 - FIRE ALARM TI - OBSERVED AS-BUILTS.pdf FA2020-0005 - FIRE ALARM TI - OBSERVED AS-BUILTS.pdf 1 DOC 9/10/2020 KOHL HETRICK FA2020-0005 RECORD OF COMPLETION.pdf FA2020-0005 RECORD OF COMPLETION.pdf 0 BOND INFORMATION 1ST PERMIT TECH (1 DAY) ARMANDO MAGALLON 6/18/2020 6/19/2020 6/29/2020 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 6/22/2020 7/6/2020 7/6/2020 APPROVED SEE ATTACHMENTS Printed: Wednesday, February 15, 2023 2:40:43 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2020-0005 NNNMMMNNNNMMMMMNNNNSCALE: 1/8" = 1'-0"04'8'12'FIRE ALARM SYSTEM TENANT IMPROVEMENT1/8"=1'-0"1ABBREVIATIONSDEVICE LEGENDWIRING LEGENDKEY NOTESTB5TB4TB3TB2EXISTING WIRINGEXISTING RISER DIAGRAMEXISTING CALC'SMMNNOTEPAD-1 79024 HIGWAY 111 SUITE 103 & 104 LA QUINTA, CA 92253 PIEOLOGY PIZZA ENTERPRISESNOTIFIERDistributorPremierSince 1954 SYSTEM SENSOR - L SERIES CEILING & WALLMOUNTED STROBES & HORN/STROBESTYPICAL DEVICE ELEVATIONS”” FIREASBUILT09-08-20M FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS PIEOLOGY PIZZA 79024 HIGHWAY 111 SUITE 103 & 104 LA QUINTA, CA 92253 FIRE ALARM SYSTEM DATA SHEETS FIRE ALARM SYSTEM BILL OF MATERIALS SYSTEM SENSOR PC2WL, SCWL – CEILING MOUNTED HORN/STROBE AND STROBE CSFM# 7135-1653:0503, 7125-1653:0504 Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383 AVDS86800 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11 ⁄16 × 4 11 ⁄16 × 2 1 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3)8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 UL Current Draw Data Horn Strobe Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86801 • 03/17 L-Series Dimensions Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White L-Series Ordering Information Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Model Description Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7135-1653:0503 Page 1 of 2 CATEGORY: 7135 -- AUDIBLE DEVICES LISTEE:System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: System Sensor Indoor 2-wire and *4-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR-2 and *TR-2W CeilingTrim Rings: *TRC-2 and *TRC-2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc July 01, 2019Date Issued:Listing Expires June 30, 2020 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator Listing No. Page 2 of 2 7135-1653:0503 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING:12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee’s Installation Instruction Manual for details. Revision 08-21-2017 dcc July 01, 2019Date Issued:Listing Expires June 30, 2020 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7125-1653:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE:System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt July 01, 2019Date Issued:Listing Expires June 30, 2020 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator Listing No. Page 2 of 2 7125-1653:0504 RATING:Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee’s Installation Instruction Manual for details. *Rev 04-04-19 gt July 01, 2019Date Issued:Listing Expires June 30, 2020 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO, Program Coordinator SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: Supplemental Pages Attached: 1.PROPERTY INFORMATION Name of property:PIEOLOGY PIZZA PAD 1 Address:79024 HIGHWAY 111 STE 103 & 104 LA QUINTA, CA 92253 Description of property:RESTAURANT Name of property representative: Address: Phone: Fax: E-mail: 2.INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor:JJJ ENTERPRISES Address:115 MARKET PL, ESCONDIDO, CA 92029 Phone:760-747-3050 Fax:760-747-7561 E-mail:INFO@JJJENT.COM Service organization:JJJ ENTERPRISES Address:115 MARKET PL, ESCONDIDO, CA 92029 Phone:760-747-3050 Fax:760-747-7561 E-mail:INFO@JJJENT.COM Testing organization:JJJ ENTERPRISES Address:115 MARKET PL, ESCONDIDO, CA 92029 Phone:760-7470-3050 Fax:760-747-7561 E-mail:INFO@JJJENT.COM Effective date for test and inspection contract: Monitoring organization:GMS Address:1127 LOMA AVE. , LONG BEACH, CA 90804 Phone:866-789-1175 Fax: E-mail: Account number:59-7378 Phone line 1: Phone line 2: Means of transmission:PHONE Entity to which alarms are retransmitted:FIRE DISPATCH Phone: 3.DOCUMENTATION On-site location of the required record documents and site-specific software:AT FIRE PANEL LOCAITON 4.DESCRIPTION OF SYSTEM OR SERVICE This is a: New system Modification to existing system Permit number:FA2020-0005 NFPA 72 edition:2016 4.1 Control Unit Manufacturer:NOTIFIER Model number:SFP-10UD 4.2 Software and Firmware Firmware revision number:2.25 4.3 Alarm Verification This system does not incorporate alarm verification. (p. 1 of 4) SYSTEM RECORD OF COMPLETION (continued) Number of devices subject to alarm verification:N/A Alarm verification set for N/A seconds (p. 2 of 4) SYSTEM RECORD OF COMPLETION (continued) 5.SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel:120VAC Control panel amps:5.0 Overcurrent protection: Type:CIRCUIT BREAKER Amps:20 Branch circuit disconnecting means location:ELELEC PANEL Number: 5.1.2 Secondary Power Type of secondary power:STORAGE BATTERIES Location, if remote from the plant:N/A Calculated capacity of secondary power to drive the system: In standby mode (hours):24 In alarm mode (minutes):5 5.2 Control Unit This system does not have power extender panels Power extender panels are listed on supplementary sheet A 6.CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line N/A N/A B 1 Device Power N/A Y B 1 Initiating Device N/A Y B 1 Notification Appliance N/A Y B 1 Other (specify): N/A N/A N/A N/A 7.REMOTE ANNUNCIATORS Type Location 8.INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations 1 ADDRESSABLE ALARM MANUAL CONTACT Smoke Detectors 1 ADDRESSABLE ALARM PHOTOELECTRIC Duct Smoke Detectors 4 CONVENTIONAL SUPERVISORY PHOTOELECTRIC Heat Detectors 0 N/A N/A N/A Gas Detectors 0 N/A N/A N/A Waterflow Switches 1 CONVENTIONAL ALARM CONTACT Tamper Switches 1 CONVENTIONAL SUPERVISORY CONTACT (p. 3 of 4) SYSTEM RECORD OF COMPLETION (continued) 9.NOTIFICATION APPLIANCES Type Quantity Description Audible Visible 2 SYSTEM SENSOR STROBES Combination Audible and Visible 2 SYSTEM SENSOR COMBINATION HORN/STROBES 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices 0 HVAC Shutdown 4 Fire/Smoke Dampers 0 Door Unlocking 0 Elevator Recall 0 Elevator Shunt Trip 0 11. INTERCONNECTED SYSTEMS This system does not have interconnected systems. Interconnected systems are listed on supplementary sheet . 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed:OTIS TAYLOR Printed name:OTIS TAYLOR Date: Organization:JJJ ENTERPRISES Title:SENIOR FIRE TECH.Phone:760-835-5617 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed:OTIS TAYLOR Printed name:OTIS TAYLOR Date: Organization:JJJ ENTERPRISES Title:SENIOR FIRE TECH.Phone:760-835-5617 12.3 Acceptance Test Date and time of acceptance test: Installing contractor representative:OTIS TAYLOR Testing contractor representative:OTIS TAYLOR Property representative: AHJ representative:KOHL HETRICK (p. 4 of 4) OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org July 6, 2020 JJJ Enterprises 41-910 Boardwalk, Ste B-15 Palm Desert, CA 92211-9089 Re: Tenant Improvement Modification - Fire Alarm System Plan Review – PIEOLOGY FA2020-0005 / 79024 HIGHWAY 111 #103, LA QUINTA, CA 92253 The fire alarm system plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1. For Central Station monitoring service, confirm that active monitoring is in place and being communicated correctly. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Function Test / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79024 HIGHWAY 111 #103 PERMIT#: FA2020-0005 DATE ISSUED: 7/6/2020 DESCRIPTION: FIRE ALARM TI – PIEOLOGY CONTRACTOR: JJJ ENTERPRISES HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.