FA2020-0008
ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT PASTION INDUSTRIES 45-450 TOWNE STREET INDIO CA 92201 (760)345-7088 JASON@PASTIONINDU STRIES.COM CONTRACTOR PASTION INDUSTRIES 45-450 TOWNE STREET INDIO CA 92201 (760)345-7088 JASON@PASTIONINDU STRIES.COM OWNER MFH PIERCE GROUP 838 SW 1ST AVE STE 210 PORTLAND OR 92253 (760)345-7088 alice@mfhllc.com CONDITIONS Description: Replacing wireless Communicator FACP Type: FIRE ALARM (WEB)Subtype: COMMERCIAL - SPRINKLER MONITORING Status: FINALED Applied: 12/1/2020 ECON Parcel No: 770151002 Site Address: 78060 CALLE ESTADO LA QUINTA,CA 92253 Approved: 12/16/2020 KHET Subdivision: DESERT CLUB TR UNIT 1 Block: 10 Lot: 5 Issued: 12/17/2020 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/3/2021 KHET Valuation: $1,500.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Wednesday, February 15, 2023 2:52:39 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2020-0008 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH-WIRE INSPECTION KHET 1/21/2021 1/21/2021 APPROVED FUNCTION TEST KHET 1/21/2021 1/21/2021 APPROVED See *Final Notes FIRE FINAL**KHET 1/21/2021 1/21/2021 DISAPPROVE D SEE NOTES It was discovered that the existing Post- Indicator Valve was not monitored though it is believed that it was in the past. Required to submit as-built plans showing PIV monitoring. Will need to test at reinspection of Final FIRE FINAL**KHET 3/3/2021 3/3/2021 APPROVED DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 3/2/21 WEB7521 518239 CREDIT PASTION INDUSTRIES ECON FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS 101-0000-42421 0 $161.00 $161.00 12/17/20 WEB6998 302182 CREDIT PASTION INDUSTRIES ECON FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS PC 101-0000-42420 0 $242.00 $242.00 12/17/20 WEB6998 302182 CREDIT PASTION INDUSTRIES ECON Total Paid for FIRE FEES: $564.00 $564.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 12/17/20 WEB6998 302182 CREDIT PASTION INDUSTRIES ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 12/17/20 WEB6998 302182 CREDIT PASTION INDUSTRIES ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$579.00 $579.00 Printed: Wednesday, February 15, 2023 2:52:39 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2020-0008 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/1/2020 EtrakitContractor 1ST SUBMITTAL PLANS J-6062 La Quinta Center.pdf 1 DOC 12/1/2020 EtrakitContractor 1ST SUBMITTAL CUT SHEETS J-6062 Submittals.pdf 1 DOC 3/2/2021 EtrakitContractor Redline for PIV Tamper J-6062_1.pdf 1 DOC 12/16/2020 KOHL HETRICK FA2020-0008 - APPROVED PLANS.pdf FA2020-0008 - APPROVED PLANS.pdf 1 DOC 12/16/2020 KOHL HETRICK FA2020-0008 - COA AND JOB CARD.pdf FA2020-0008 - COA AND JOB CARD.pdf 1 DOC 3/3/2021 KOHL HETRICK Permit Details Permit Details.pdf 0 BOND INFORMATION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 12/1/2020 12/15/2020 12/16/2020 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 12/1/2020 12/2/2020 12/3/2020 COMPLETE PARENT PROJECTS Printed: Wednesday, February 15, 2023 2:52:39 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2020-0008 FA2020-0008 SCALE: 1/8" = 1'PROJECT TITLE:0DPGFOR APPROVALSHEET TITLE:FIRE SPRINKLERMONITORING SYSTEMJOB NO.:DATE:SCALE:DRAWN BY:CHECKED BY:SHEET NO.:SHEETDPG REF. NO.:NO.INIT.REVISIONSDATEDESCRIPTION11/20/2020J-6062J-606211/20/2020LA QUINTA EXECUTIVE CENTER78060 Calle estadoLa Quinta, CA 92253PASTION INDUSTRIES INC.45-450 Town StreetIndio, CA 92201 State Contractors License C-10 # 736561Tel.(760) 345-7088 FAX (760) 347-6038FLOOR PLANFA - 0202 of 02AS NOTEDGROUND FLOORBATTERY CALCULATIONS FOR FACP - BOSCH FPD-7024MODELSTANDBYEXTENDEDALARMEXTENDEDQTY.MANUFACTURERNUMBERDESCRIPTIONCURRENTSTANDBYCURRENTALARM1BoschFPD-7024Fire Alarm Control Panel0.200000.200000.380000.380001BoschD263Smoke Detector0.001000.001001.000001.000001System SensorHRLHorn0.000000.000000.044000.04400Panel Voltage:24VDCTotal Standby:0.2010Total Alarm:1.4240Battery Voltage:12VDCHours in Standby:24Minutes in Alarm:5Battery Capacity:7Amp HoursStandby AH:4.8240Alarm AH:0.1187De-Rating Factor:20%Number of Batteries:2Total Capacity Used:4.9427Total Battery Capacity:7Amp Hours @ Panel VoltageBattery Capacity:7.0000De-Rated Battery Capacity:5.6000Spare Amp Hours:0.6573Spare Amp Hours Percentage:11.74%BATTERY CALCULATIONS FOR RADIO COMMUNICATOR - AES 7707MODELSTANDBYEXTENDEDALARMEXTENDEDQTY.MANUFACTURERNUMBERDESCRIPTIONCURRENTSTANDBYCURRENTALARM1AES7707Radio Communicator0.200000.200001.200001.20000Panel Voltage:12VDCTotal Standby:0.2000Total Alarm:1.2000Battery Voltage:12VDCHours in Standby:24Minutes in Alarm:5Battery Capacity:7Amp HoursStandby AH:4.8000Alarm AH:0.1000De-Rating Factor:20%Number of Batteries:1Total Capacity Used:4.9000Total Battery Capacity:7Amp Hours @ Panel VoltageBattery Capacity:7.0000De-Rated Battery Capacity:5.6000Spare Amp Hours:0.7000Spare Amp Hours Percentage:12.50%NOTIFICATION APPLIANCE CIRCUIT (NAC) LISTZONE# OFCIRCUITWIREPATHWAYPATHWAYPREFIX#DEVICESDEVICE TYPELOCATIONORIGINIDCLASSSURVIVABILITYN11HornReceptionFACPAB0INITIATING DEVICE CIRCUIT (IDC) LISTZONECIRCUITWIREPATHWAYPATHWAYPREFIX#DEVICE TYPELOCATIONORIGINIDCLASSSURVIVABILITYZ1Smoke DetectorAt FACPFACPDB0Z2Waterflow SwitchBy StairsFACPDB0FIRE ALARM SYSTEM SEQUENCE OF OPERATIONSREACTIONACTIONRADIOSMOKEWATERFLOWCOMMPOWERSYSTEMDETECTORSWITCHTROUBLEFAILURETROUBLEANNUNCIATE AT FIRE ALARM CONTROL PANELXXXXXACTIVATE NOTIFICATION APPLIANCESXXACTIVATE CENTRAL STATION CONNECTION - ALARMXXACTIVATE CENTRAL STATION CONNECTION - SUPERVISORYACTIVATE CENTRAL STATION CONNECTION - TROUBLEXXXVOLTAGE DROP CALCULATIONS FOR NOTIFICATION CIRCUIT: N1Voltage:20.4VDCTemperature:167Fahrenheit =75.0CentigradeWire Gauge (AWG):14AWG =4110Circ Mils =0.00319Ohms/ FootNUMBERCONDUCTOROFLENGTHTOTALAWGCIRCULAROHMSVOLTAGEPERCENTDEVICES(FEET)AMPERESSIZEMILSPER FOOTDROPDROP1100.04401441100.003190.0030.01%Total Voltage Drop0.003VoltsTotal Percentage Voltage Drop in Circuit0.01PercentWIRE DESCRIPTION TABLEWIRE IDAWGCONDUCTOR TYPETYPEDESCRIPTIONTYPECIRCUIT ORIGIND18Solid18/2 FPLInitiatingIDCFACPA14Solid14/2 FPLIndicatingNACFACPDefinitions:FPLPower-limited fire alarm cable listed as being suitable for general-purpose fire alarm use,with the exception of risers, ducts, plenums, and other space used for environmental airand shall also be listed as being resistant to the spread of fire.FPLRPower-limited fire alarm riser cable listed as being suitable for use in a vertical run in ashaft or from floor to floor and shall also be listed as having fire-resistant characteristicscapable of preventing the carying of fire from floor to floor.THHNThermoplastic High Heat Resistant Nylon Coated Cable.THWNThermoplastic Heat and Water Resistant Nylon Coated Cable.Cable within seven (7) feet of finished floor must be protected from physical damage.Cable above seven (7) feet may be exposed, and supported, unless AHJ requires otherwise.Use Type "THWN" For Wet/ Damp Locations.SCALE: 1/8" = 1'SECOND FLOORROOM #7ROOM #8ROOM #12ROOM #11CONFERENCE ROOMCOURT YARDROOM #6ROOM #5ROOM #4ROOM #3ROOM #2ROOM #1ROOM #9ROOM #10RECEPTIONLOUNGEROOM #14ROOM #15ROOM #16ROOM #19ROOM #18ROOM #17MEN RESTROOMWOMENRESTROOMWOMENRESTROOMMENRESTROOMWFPSHFACPDOCUMENTCABINETFACZ1Z2N1DADROOM #20ROOM #21 Submittal Package for: La Quinta Executive Center 78060 Calle Estado La Quinta, CA 92253 Pastion Industries 45-450 Towne Street Indio, CA 92201 Contains Cutsheets and CSFM Listings for: Fire Alarm Control Panel Radio Communicator Smoke Detector Horn Fire Alarm Systems | FPD‑7024 Fire Alarm Control Panels The FPD‑7024 Fire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. They are listed by UL for central station, local, auxiliary, and remote station systems. The FPD‑7024 FACPs support four on‑board initiating zones that can be expanded to eight using the FPC-7034. Each initiating zone supports two‑wire and four‑wire detectors configurable as Class A , Style D or Class B, Style B loops. Each zone can support up to 20 two‑wire detectors, or any number of four‑wire detectors depending on available power. Each FACP has a built‑in digital fire alarm communicator transmitter (DACT). Enhance the FPD‑7024 conventional system features by adding a D7039 Multiplex Expansion Module. Adding a D7039 Multiplex Expansion Module to the FPD‑7024 turns the conventional FACP into an addressable FACP. The D7039 adds up to 247 addressable points to the base system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases the number of programmable relay outputs from 19 to 59 and expands system users to 100. Functions Notification Appliance Circuits (NACs) Two Class A, Style Z or Class B, Style Y NACs provide up to 4 A of regulated 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, California March, steady, pulsed, and synchronized output for either Wheelock or System Sensor notification appliances. User Interface A viewing port in the locked control panel enclosure door shows the system status light‑emitting diodes (LEDs) and liquid‑crystal display (LCD) while maintaining system keypad security. Unlocking the enclosure door provides access to the system controls for silencing off‑normal conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all FMR‑7033 LCD Keypads connected to the system. Organized Event Display Sorts alarm, trouble, and supervisory events into categories and allows scrolling through specific events. History Buffer The system stores events in a 99‑event history buffer. Note The number of events that can be stored in the history buffer increases to 499 with the FPD‑7024 Fire Alarm Control Panels ▶Four initiating zones (expandable to eight); up to 20 two‑wire smoke detectors per zone ▶Built‑in DACT ▶Two notification appliance circuits (NACs) on board with a shared internal regulated 24 VFWR, 4 A NAC power supply ▶Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module ▶Programmable through front panel interface, remote FMR‑7033 Liquid‑crystal Display (LCD) Keypads, remote programming software (RPS), or DX4010V2 or DX4020 www.boschsecurity.com 2 | FPD‑7024 Fire Alarm Control Panels addition of a D7039 Multiplex Expansion Module. Central Station Reporting The FPD-7024 FACPs send reports to two telephone numbers (or IP addresses with a DX4020 Network Interface Module installed) with full single, double, and backup reporting. They communicate in BFSK, SIA, Contact ID, Modem IIIa2, and 4/2 and 3/1 Tone Bursts. Dirty Smoke Detector Monitoring All on‑board zones and FPC‑7034 zones are continuously monitored for smoke detectors signaling a dirty condition using the Bosch Chamber Check feature and CleanMe protocol. If a detector's smoke chamber is dirty, the detector sends a CleanMe signal on the two‑wire loop or a dirty detector signal on the addressable loop. The control panel annunciates that there is a dirty detector on the loop or the address. The Chamber Check feature signals a dirty smoke chamber using the LED on the detector head. Accessories The FPD‑7024 enclosure has space for additional accessory modules and two D1218 (18 Ah) batteries or two D126 (7 Ah) batteries. Certifications and Approvals Region Certification USA UL UOXX: Control Unit Accessories, System (ANSI/UL 864) FM CSFM 7165-1615:0227 FIRE ALARM CONTROL UNIT (COMMERCIAL) FCC ESVAL04B7024 FDNY- CoA #6024 Brazil ANATEL 0383-11-1855 Installation/Configuration Notes Compatible Products The following products are compatible with the FPD‑7024 FACP: Category Product ID Product Description Batteries and D126 12 V, 7 Ah battery Power Supplies D1218 12 V, 18 Ah battery D7038 Remote NAC power supply Detectors For two‑wire detector compatibility, refer to FPD‑7024 Smoke Detector Compatibility List Technogram (P/N: F01U010790) Category Product ID Product Description Keypads and Annunciators D7030X Eight‑point LED annunciator (eight red) D7030X‑S2 Eight‑point LED annunciator (two yellow, six red) D7030X‑S8 Eight‑point LED annunciator (eight yellow) D7032 Eight‑point LED annunciator expander (eight red) FMR‑7033 LCD fire system keypad FMR‑7036 LCD annunciator Modules D132B Smoke detector reversing relay module D184A Local energy kit D185 Reversing polarity module D275 EOL power supervision module FPC‑7034 Four‑point expander D7039 Multiplex expansion module Option Bus Devices D7035 Octal relay module D7035B Octal relay module in box DX4010V2 USB/serial interface module DX4020 Network interface module NAC Devices Refer to FPD‑7024 Device Compatibility List Technogram (P/N: F01U010791) The following additional products are compatible with the FPD‑7024 Addressable FACPs: Category Product ID Product Description Detector Heads and Bases D7050 Addressable Photoelectric Smoke Detector Head D7050TH Addressable Photoelectric Smoke and Heat Detector Head D7050‑B6 Detector Base Modules D7042 Multiplex eight‑input remote module D7042B Multiplex eight‑input remote module in box D7044 Multiplex single‑input module D7044M Mini multiplex single‑input module D7048 Multiplex octal driver D7048B Multiplex octal driver in box D7052 Multiplex dual‑input module D7053 Multiplex input‑output module Pull Stations FMM‑7045 Single‑action manual station FMM‑7045‑D Double‑action manual station FPD‑7024 Fire Alarm Control Panels | 3 Parts Included Quant. Component 1 FPD‑7024 board in a static‑resistant bag 1 Enclosure (P/N: 30897) 1 Lock set with two #1358 (D102) keys (P/N: F01U009775) 1 Transformer (P/N: F01U008702) 6 2.21 kΩ end‑of‑line (EOL) resistors (P/N: 25899 or 4998113202) 1 Hardware pack 1 Literature pack Note For the FPD‑7024 to be addressable, a D7039 Multiplex Expansion Module must be installed. The D7039 is purchased separately. Technical Specifications Electrical Current (alarm): 380 mA Current (standby): 200 mA Power (primary): 120 VAC, 1.2 A maximum, 60 Hz or 240 VAC, 0.75 A maximum, 50 Hz Environmental Environment:Indoor, dry Relative Humidity: Up to 95%, non-condensing Temperature (operating): +32°F to +120°F (0°C to +49°C) Mechanical Properties Color:Red Dimensions (HxWxD): 20.8 in. x 15 in. x 4.3 in. (52.8 cm x 38.1 cm x 10.9 cm) Material:Cold-rolled steel Base: 18 gauge (1.2 mm) Cover: 19 gauge (1.1 mm) Indicating Device Circuits (IDC) Current:44 mA maximum per loop Line resistance:150 Ω Voltage:24 VDC nominal Outputs NAC:24 VDC nominal, 4 A maximum On-board Relays: Three Form C contacts rated at 5 A, 28 VDC Off-board Relays: Up to two D7035 Octal Relay Modules with each providing eight Form C relay outputs; contacts rated at 5 A, 28 VDC In an addressable system, up to 20 D7053 Multiplex Input-Output Modules are allowed per bus for a total of 40 Trademarks Trademark names are used throughout this document. In most cases, these designations are claimed as trademarks or registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc. uses the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringing the trademark. Chamber Check is a registered trademark of Bosch Security Systems, Inc. in the United States. CleanMe is a registered trademark of GE Interlogix in the United States and/or other countries. Wheelock is a trademark of Cooper Wheelock, Inc. System Sensor is a registered trademark of System Sensor, a brand of Honeywell International, Inc. in the United States and/or other countries. Ordering Information FPD-7024 FACP Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone FPD-7024 FPD-7024-LC FACP without Enclosure and Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone FPD-7024-LC FPD-7024-LT FACP without Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone. Available only in Latin America. FPD-7024-LT www.boschsecurity.com 4 | FPD‑7024 Fire Alarm Control Panels Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.asia Represented by © Bosch Security Systems Inc. 2011 | Data subject to change without notice T3761282827 | Cur: en-US, V12, 22 Mar 2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7165-1615:0227 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE:BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Peter Namisnak (585) 678-3655 Fax (585) 678-3263 Email: peter.namisnak@us.bosch.com DESIGN: Model FPD-7024 fire alarm control unit. Power limited, local, automatic, manual, coded, noncoded, remote station (PPU), proprietary (PPU), central station (PPU), waterflow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: FPD-7024; Control Unit FPC-7034; 4-Zone Expander FMR-7033, FMR-7036; Keypad D7035, D7035B; Expanded Relay Module D185; Reverse Polarity Module D7039, *FPE-7039; MUX Expander D7042, D7042B, D7044, D7044M, D7052, D7053; Mulitplez Expander Module D7048, D7048B; Octal Driver Module B440, B441, B443; Cellular Modules B450; Interface Module *FLM-7024-ISO; MUX Bus Isolator Module RATING:120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee’s printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee’s name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee’s Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Revsion 02-15-17 gt July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. aes-corp.com New Feature Highlights • Leverages state of the art technology• Applies advanced security protection• Offers flexible power and configuration options• Engineered for backward compatibility with legacy systems• Enables future ready capabilities• Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Improves functionality with an adaptive Graphic User Interface (GUI) for programming via smartphones, tablet and PCs• Plus many more… Key Benefits that Make 2.0 the Best Alarm Monitoring Solution Ever • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks• Protects subscriber units against unauthorized access and rogue activity with a password protected Dealer Code• Makes programming and streamlined troubleshooting easy with user friendly interface• Adds integrated supervision of AES-IntelliPro full data module• Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP) without requiring an electrician onsite and without Subscriber backup battery (2) Directly from the FACP with Subscriber backup battery; or (3) Traditional installation with plug in Class 2 low power transformer• Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure• Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards Introducing a Newer, Smarter Alarm Communications Platform 7707 Fire Subscribers www.aes-corp.com Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option, they are the ideal drop-in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board. AES subscribers’ intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: http://aes-corp.com/products/fire/fire-marshal-resources/ www.aes-corp.com How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM (UL & ULC Listed, Available Now!) 7707P-88 IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones, with integrated onboard Local Annunciator, Red Enclosure 7707P-88-ULP IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794A AES-IntelliPro and integrated onboard Local Annunciator, Red Enclosure 7707P-44 IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones, with integrated onboard Local Annunciator, Red Enclosure 7707P-44-ULP IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones with 7794A AES-IntelliPro and integrated onboard Local Annunciator, Red Enclosure 2.0 FEATURE ADD (Pending UL Review) 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber, 4 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-44-ULP-M IntelliNet 2.0 Fire Subscriber, 4 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707M-UPG IntelliNet 2.0 Fire MCT Software Upgrade 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy Fire Subscribers 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure 7744F-ULP-P Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version www.aes-corp.com www.aes-corp.com AES Corporation | 285 Newbury Street | Peabody, MA 01960 United States © Copyright 2017 AES Corporation and AES-IntelliNet® are registered trademarks of AES Corporation 7707_05252017_F DIMENSIONS 13”H x 8.5”W x 4.5”D (33cmH x 21.5cmW x 11.4cmD) WEIGHT 5.8 lbs (2.6 kilograms) excluding battery 13 lbs (5.9 kilograms) with 10 Ah battery RADIO FREQUENCY Standard Frequency Range: 450-470 MHz Contact AES for other UHF and VHF frequencies ANTENNA 2.5 dB tamper resistant antenna included, mounts on enclosure Optional remote mounting antenna available POWER INPUT AC SOURCES Transformer: Class 2 16.5V AC nominal output 1.9 A max current (40 VA MIN) ELK ELK-TRG1640, MG ELECTRONIC SALES MGT1640, or AES 1640 (not included) DC SOURCES (includes FACP) 24V DC Regulated Power Supply with Subscriber Rechargeable Battery 1.9 A max current BACKUP BATTERY 10-12 Ah, UL recognized lead acid gel cell, size based on subscriber configuration PORTS Ethernet for configuration and message communication USB access for software upgrade REMOTE ANNUNCIATOR AES Model 7740 Remote Annunciator, supervised COMPATIBLE RECEIVERS 7705i AES-MultiNet Receiver CONFIGURATION INTERFACE Web browser capable device accessible via smartphone, tablet, laptop, or PC CURRENT CONSUMPTION Standby w/ charged backup battery: 200 mA (1.2 A Transmitting) Standby + charging backup battery: 900 mA (1.9 A Transmitting - MAX) POWER OUTPUT 2 or 5 Watts Factory set ENCLOSURE MATERIAL Steel with paint finish FINISH COLOR Red VISUAL INDICATORS Front panel LCD (2 x 20 alphanumeric character backlit display) Power and Trouble LEDs (ALM, Trouble, Tx, Rx, WA) ALARM SIGNAL INPUTS/ZONES · 8 individually programmable E.O.L. type zone inputs · 4+4: 4 reverse polarity input and 4 individually programmable E.O.L. type zone inputs · Optional 7794A AES-IntelliPro for full data via Contact ID, Pulse, Modem IIe and Modem IIIa2 UL LISTINGS UL 864 10th Edition Standard for Control Units and Accessories for Fire Alarm Systems ULC S559-04 1st Edition Equipment for Fire Signal Receiving Centres and Systems TROUBLE OUTPUT—ACK DELAY/ANTENNA CUT Form C relay, fail secure, rated 24V DC 1A resistive, unsupervised RESET BUTTON Located on main circuit board OPERATING TEMPERATURE 32 to 120°F (0 to 49°C) STORAGE TEMPERATURE 14 to 140°F (-10 to 60°C) RELATIVE HUMIDITY 0 to 93%, non-condensing RECHARGE CAPABILITY Will charge 12V battery size from 10-12 Ah Technical Specifications 7707 Fire Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7300-1516:0501 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:AES CORPORATION285 NEWBURY ST, PEABODY, MA 01960 Contact: Revathi Pillai (978) 839-7063 Fax (978) 535-7313 Email: rpillai@aes-corp.com DESIGN: AES Model 7707 Subscriber Unit, one-way RF receiver and listed accessories intended to be connected to a separately listed fire alarm control unit. Accessories listed for use with this unit are subassembly modules 7711 and 7712, and 7794A digital dialer interface. Refer to listee’s Installation Instruction Manual for details. RATING:120 VAC, 60Hz, 1.75 Amp 24VDC, 1.3 Amp INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a subscriber unit for use with separately listed AES Model 7705i receiver (CSFM # 7300-1516:0104) and Model 7170 IP-Link (CSFM # 7300-1516:0105). 05-19-2017 dcc July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Fire Alarm Systems | D263 Series Photoelectric Smoke and Smoke and Heat Detectors The D263 Series includes the following detector models: Model Description D263 Two-wire D263TH Two-wire with 135°F (57°C) heat sensor D263THC Two-wire with 135°F (57°C) heat sensor and auxiliary relay D263THS*Two-wire with 135°F (57°C) heat sensor and sounder * Sounders produce 85 dB at 10 ft (3 m). Each of the D263 Series Detector models is UL Listed and works with commercial fire protective signaling and household fire warning systems. Each model detects smoke particles produced during wood, paper, and fabric combustion. System Overview The D263 Series Detector models use an infrared (IR) LED light source and a silicon photodiode to measure light in a chamber. A fine screen covers the chamber to deter insects and to reduce dust accumulation and nuisance alarms. During a fire, smoke particles reflect light onto the photodiode. When the photodiode measurements exceed the alarm threshold, the detector signals an alarm condition. After the alarm condition clears, interrupt power at the control panel to reset the detector. Use a D132B Reversing Relay Module to activate the sounder (85 dB at 10 ft [3 m]). When using a D132B, the LED does not latch on alarm. Functions Chamber Calibration Tests Check the sensitivity and calibration of any D263 Series Detector model using a visual check, a magnet test, or a voltage measurement test. Visual check: When the detector’s calibration is within the factory-listed range, the red alarm LED flashes once every 3.5 sec. If the detector’s calibration is out of range for more than 24 h, the red alarm LED flashes once a second. Magnet test: Hold a magnet horizontally against the detector for about 10 sec and observe the LED. •If the detector is within the factory-listed calibration range, it goes into alarm and the Alarm LED latches on.•If the detector is too sensitive, the LED rapidly flashes six times (once every half second) and the detector goes into alarm.•If the detector is not sensitive enough, the LED slowly flashes four times, once every 2 seconds, and the detector goes into alarm. D263 Series Photoelectric Smoke and Smoke and Heat Detectors ▶12 V or 24 V input ▶Designed for commercial or residential use ▶Two-wire application ▶Light-emitting diodes (LEDs) indicate the status of the chamber, power, and alarm ▶Removable terminal block to simplify wiring connections ▶Cable connection point for voltmeter sensitivity test ▶Trim Plate TP280 for retrofit and remodeling purposes www.boschsecurity.com 2 | D263 Series Photoelectric Smoke and Smoke and Heat Detectors •If the detector does not operate, it does not signal an alarm. Voltage measurement test: Use a D1005 Test Cable and a digital voltmeter to measure the voltage and compare the results with the factory-listed sensitivity range. Certifications and Approvals Region Certification USA UL UROX: Smoke - Automatic Fire Detectors (UL268 and A), UROX7: Smoke - Automatic Fire Detectors Certified for Canada (cULus), CSFM 7272-1615: 134 NYC-MEA 274-93-E, Vol. VII MSFM Hong Kong HKFSD D263THC only D263THS only Installation/Configuration Notes Use smoke detectors for detection circuits that protect people. Use heat detectors for circuits that protect property. Compatible Products The following products are compatible with the D263 Series detectors: Category Product ID Product Description Control Panels Bosch Security Systems makes no claim written, oral, or im- plied that the D263 Series detectors work with any two-wire control panels except those specified in the Control Panel Compatibility chart in Technical Service Note (P/N: 31866). Modules D132B Reversing relay module Mounting The detector has a mounting plate that attaches on a standard four-inch back box. For commercial and industrial installations in accordance with NFPA 72, space each detector 30 ft (9.2 m) apart. Wiring The terminal block accepts up to 12 AWG (2.3 mm) wire. You can remove the terminal block from the detector for easier wiring. The terminal block snaps in and out of the detector. Technical Specifications Environmental Considerations Radio Frequency Interfer- ence (RFI) Immunity: No alarm on critical frequencies in the range of 26 MHz to 950 MHz. Relative Humidity:Up to 93%, non-condensing Temperature (operating):+32°F to +120°F (0°C to +40°C) Mechanical Properties Dimensions (Diameter x H):5 in. x 2 in. (12.7 cm x 5.1 cm) Material:High impact, fire retardant ABS plastic Relay Contacts Auxiliary Form C: 1 A, 120 VAC/30 VDC at 1 A, 30 W maximum Power Requirements Current Draw (alarm):Determined by control panel Current Draw (standby):0.080 mA at 12 V, 0.1 mA maximum Current Draw (start-up):0.12 mA Current Draw (trouble):0.1 mA maximum Power-up Time:22 sec maximum RMS Ripple (maximum):25% of DC input Voltage (stand-by):8.5 VDC to 33 VDC Ordering Information D263 Two‑Wire Smoke Detector Two‑wire photoelectric smoke detector. D263 D263TH Two‑Wire Smoke/Heat Detector Two‑wire photoelectric smoke detector with a 135°F (57°C) heat sensor. D263TH D263THC Two‑Wire Smoke/Heat Detector with Auxiliary Relay Two‑wire photoelectric smoke detector with a 135°F (57°C) heat sensor and an auxiliary re- lay. D263THC D263THS Two‑Wire Smoke/Heat Detector with Sounder Ttwo‑wire photoelectric smoke detector with a 135°F (57°C) heat sensor and a sounder. D263THS Accessories D1005 Test Cable Connects a digital voltmeter to the detector's calibration pin for verifying that the detector is within its calibration range D1005 DT‑2 Detector Removal Tool Use the DT‑2 to remove, replace, or test the detector head DT-2 TP280 Trim Plate For retrofit and remodeling purposes; 16.2 cm (6 in.) diameter TP280 D263 Series Photoelectric Smoke and Smoke and Heat Detectors | 3 www.boschsecurity.com 4 | D263 Series Photoelectric Smoke and Smoke and Heat Detectors Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.com Represented by © Bosch Security Systems Inc. 2010 | Data subject to change without notice T1312425227 | Cur: en-US, V9, 4 Jul 2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7272-1615:0134 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE:BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Peter Namisnak (585) 678-3655 Fax (585) 678-3263 Email: peter.namisnak@us.bosch.com DESIGN: Models D285, D285DH, D285TH, D263, D263TH, D273, D273TH, D273THS, D263THC, D263THS, D273THR, D273THC, D273IS, D273THCS, D273THSR, D273THE, D273ES and D273THES smoke detectors. Model D285TH, D263TH and D273THxx employ an integral 1350 fixed temperature heat detector. This heat sensor is intended for use only as a supplemental device to assist the smoke detector. *Model D285 series are separable detector heads which operate with separable base Models D287, D288, D292, D293A, D293E and D293S. *Models D263 and D273 series detectors are nonseparable detector heads with terminal blocks and do not operate with separable bases. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:8.5 - 33.0 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control unit. Models D285 and D285TH are intended for use with separately listed bases. Model D285DH is intended for use with separately listed Duct Smoke Detector Housing Model D341 or D342 (CSFM Listing No. 3240-1615:181) or Model D340 (CSFM Listing No. 3240-1615:184). Refer to listee’s Installation Instruction Manual for details. NOTE: Formerly 7272-0801:162 *Rev. 05-29-2007 jw July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383, 3057072 Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 × 4 × 17⁄8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411 ⁄16 × 411 ⁄16 × 21 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1,2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 1.91˝ D (143 mm L × 119 mm W × 49 mm D) Compact Wall-Mount Dimensions (including lens)5.26” L x 3.46” W x 1.91” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.25˝ D (143 mm L × 119 mm W × 32 mm D) Compact Horn Dimensions 5.25” L x 3.45” W x 1.25” D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9*Coded High 85 90 90 10*3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Candela Range (15–115 cd) DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Current Draw Data Horn Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86503 • 03/17 L-Series Dimensions Model Description Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT L-Series Ordering Information Notes: All -P models have a plain housing (no “FIRE” marking on cover) All -SP models have “FUEGO” marking on cover All -ALERT models have “ALERT” marking on cover Compact Strobe / Horn Strobe Strobe / Horn Strobe Compact Horn Horn Model Description Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7135-1653:0503 Page 1 of 2 CATEGORY: 7135 -- AUDIBLE DEVICES LISTEE:System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: System Sensor Indoor 2-wire and *4-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR-2 and *TR-2W CeilingTrim Rings: *TRC-2 and *TRC-2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Listing No. Page 2 of 2 7135-1653:0503 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING:12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee’s Installation Instruction Manual for details. Revision 08-21-2017 dcc July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org December 16, 2020 Pastion Industries 45450 Towne Street Indio, CA 92201 Re: Monitoring Fire Alarm System Plan Review – EXECUTIVE OFFICES FA2020-0008 / 78060 CALLE ESTADO, LA QUINTA, CA 92253 The fire alarm system plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Function Test / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78060 CALLE ESTADO PERMIT#: FA2020-0008 DATE ISSUED: 12/16/2020 DESCRIPTION: REPLACING FACP CONTRACTOR: PASTION INDUSTRIES HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.