Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FA2021-0004
ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT Manny Puga 73168 hwy 111 suite 204 palm desert CA 92260 (760)322-1562 manny@desertalarm.c om BILL TO desert alarm 73168 hwy 111 suite 204 palm desert ca 92260 (760)322-1562 manny@desertalarm.c om CONTRACTOR DESERT ALARM INC 73168 HWY 111 #204 PALM DESERT CA 92260 (760)322-1562 INFO@DESERTALARM. COM OWNER SHADOW ROCK CHURCH 46760 COMMERCE CT LA QUINTA CA 92253 (760)322-1562 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE KAYLI ALFORD 3/12/2021 3/12/2021 ISSUED AS OF THE DATE OF APPROVAL - 3/10/21. APPROVED BY KOHL. CONDITIONS Description: SHADOW ROCK CHURCH - NEW FIRE ALARM / BCOM2020-0009 Type: FIRE ALARM (WEB)Subtype: COMMERCIAL - FIRE ALARM SYSTEM Status: FINALED Applied: 3/1/2021 EPRS Parcel No: 600390018 Site Address: 46760 COMMERCE CT LA QUINTA,CA 92253 Approved: 3/10/2021 KHET Subdivision: PM 29351 Block: Lot: 8 Issued: 3/10/2021 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 4/2/2021 KHET Valuation: $6,685.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Thursday, February 23, 2023 3:36:58 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2021-0004 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH-WIRE INSPECTION KHET 3/23/2021 3/23/2021 APPROVED SEE NOTES FOR REQUIREMENTS *Revised plans/calcs based on "As-built" changes are required prior to final inspection. Need to confirm need for additional notification appliances in Storage now converted to Offices. Also observed Prayer Room 1 as MPR, Prayer Room 2 as Nursery and Prayer room 3 as Preschool. FUNCTION TEST KHET 3/31/2021 3/31/2021 APPROVED SPRINKLER MONITORING KHET 3/31/2021 3/31/2021 APPROVED 24 HR. BATTERY TEST KHET 4/1/2021 4/1/2021 APPROVED FIRE FINAL**KHET 4/1/2021 4/2/2021 APPROVED Pending Record of Completion FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE ALARM SYSTEMS 101-0000-42421 0 $483.00 $483.00 3/1/21 WEB7514 063130 CREDIT Manny Puga EPRS FIRE ALARM SYSTEMS PC 101-0000-42420 0 $564.00 $564.00 3/1/21 WEB7514 063130 CREDIT Manny Puga EPRS Total Paid for FIRE FEES: $1,047.00 $1,047.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 3/1/21 WEB7514 063130 CREDIT Manny Puga EPRS Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 3/1/21 WEB7514 063130 CREDIT Manny Puga EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$1,062.00 $1,062.00 Printed: Thursday, February 23, 2023 3:36:58 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2021-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/1/2021 EtrakitPublicReg 1ST SUBMITTAL - PLAN SET J-6147 Shadow Rock Church.pdf 1 DOC 3/3/2021 EtrakitPublicReg shadow Submittals.pdf 1 DOC 3/26/2021 EtrakitPublicReg J-6147 Shadow Rock Church REV 1.pdf 1 DOC 3/10/2021 KOHL HETRICK FA2021-0004 - APPROVED PLANS.pdf FA2021-0004 - APPROVED PLANS.pdf 1 DOC 3/10/2021 KOHL HETRICK FA2021-0004 - COA AND JOB CARD.pdf FA2021-0004 - COA AND JOB CARD.pdf 1 DOC 3/23/2021 KOHL HETRICK 3-23-2021 Inspection Notes.pdf 3-23-2021 Inspection Notes.pdf 1 DOC 3/30/2021 KOHL HETRICK FA2021-0004 - REVISED PLANS - APPROVED.pdf FA2021-0004 - REVISED PLANS - APPROVED.pdf 1 BOND INFORMATION FIRE FINAL**KHET 4/1/2021 4/2/2021 APPROVED Contractor provided the Record of Completion on 4/2 via email. Not reviewed until today. REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 3/1/2021 3/15/2021 3/10/2021 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) ARMANDO MAGALLON 3/1/2021 3/2/2021 3/2/2021 COMPLETE 1ST FIRE (1 WK)KOHL HETRICK 3/26/2021 4/2/2021 3/30/2021 APPROVED REVISED PLANS/CALCS PARENT PROJECTS Printed: Thursday, February 23, 2023 3:36:58 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2021-0004 SYMBOL LEGENDTOTALSYMBOLDESCRIPTIONMANUFACTURERMODEL NUMBERCSFM LISTINGBACKBOXMOUNTING HEIGHT1 Fire Alarm Control PanelHoneywellVista-32FB7165-1645:0123Custom 72" AFF to Top1 Remote AnnunciatorHoneywell61607300-1645:0115Custom 60" AFF to Center of Display1 Power SupplyAltronixAL602ULADA7315-1335:0103Custom 72" AFF to Top1 Cellular CommunicatorTelguardTG-7FS7300-1402:0110Custom 72" AFF to Top1 Document CabinetSpace Age ElectronicsACE-117300-0553:0110Custom 72" AFF to Top1 Smoke DetectorSystem Sensor 2W-B7272-1653:01524SOn Ceiling2 Manual Pull StationSilent KnightPS-SA7150-0559:0140Single Gang48" AFF to Top of Action1 Waterflow Switch EXISTNGEXISTING EXISTING EXISTINGN/AVerify in Field1 PIV Tamper Switch EXISTNGEXISTING EXISTING EXISTINGN/AVerify in Field2 Horn/Strobe @ 15cd CeilingSystem SensorPC2RL7135-1653:05034SOn Ceiling3 Horn/Strobe @ 75cd CeilingSystem SensorPC2RL7135-1653:05034SOn Ceiling2 Horn/Strobe @ 75cdSystem Sensor P2RL7135-1653:05034SEntire Lens Between 80" and 96" AFF1 Horn/Strobe @ 110cdSystem Sensor P2RL7135-1653:05034SEntire Lens Between 80" and 96" AFF2 Horn/Strobe @ 135cdSystem Sensor P2RL7135-1653:05034SEntire Lens Between 80" and 96" AFF4 Horn/Strobe @ 185cdSystem Sensor P2RL7135-1653:05034SEntire Lens Between 80" and 96" AFF1 Fire Bell EXISTINGEXISTING EXISTING EXISTING EXISTINGVerify in FieldFIRE ALARM SYSTEM NOTESSHEET INDEXSHEETDRAWING##DESCRIPTIONFA-011Fire Alarm System Cover SheetFA-022Fire Alarm System Ground FloorFA-033Fire Alarm System MezzanineDO NOT PROCEED WITHOUT APPROVED PRINTSBuilding Information: TENANT IMPROVEMENTAPN:600-390-018Occupancy Class:A-3Occupant Load:Ground Floor = 638; Mezzanine = 46; Total = 684Sprinkered:V-B, Fully SprinkleredStories:2Area:Ground Floor = 11,894 SF; Mezzanine = 3,606 SF; Total = 15,500 SFCentral Station:CMS2210 Landmark PlaceManasquan, NJ 08736Phone #: (888) 890-1020UL #: S3072-2 (UUFX)Scope of Work:Install a new fire alarm system for the tenant improvement of an existing building.Comply with all building and fire alarm codes referenced in this submittal.BUILDING INFORMATIONVICINITY MAPPLASTIC JACKETED CABLECONCRETE WALL OR FLOORPACKING MATERIALSECTION A-APUTTYAANOTES:Fill, Void or Cavity Material* - Putty - Moldable putty material kneaded by hand and applied to fill annular space (and interstices between cables to maximum extent possible) to a minimum depth of 1 inch, flush with top surface of floor or sleeve in wall assemblies, required putty depth to be installed symmetrically on both sides of wall.Minnesota Mining & Mfg. Co. - Type MPS-2* Bearing the UL Classification MarkingUL System #C-AJ-3021PLASTIC JACKETED CABLEWALL ASSEMBLYSECTION A-APUTTYANOTES: Minnesota Mining & Mfg. Co. - Type MPS-2* Bearing the UL Classification MarkingUL System #W-L-3031APUTTYSTEEL SLEEVESTEEL SLEEVEFill, Void or Cavity Material* - Putty - Minimum 1 inch thickness moldable putty packed tightly into annular space between cables and steel sleeve (and interstices between cables, if possible), flush with each end of steel sleeve. A nominal 1/4 inch diameter continuous "rope" or putty shall be applied around the circumference of the steel sleeve at its egress from the gypsum wallboard layers on both sides of the wall assembly.CONCRETE FLOORRIGID STEEL CONDUITSECTION A-ACAULKINGAANOTES:Fill, Void or Cavity Material* - Caulk - Applied to fill annular space flush with top surface of floor. In wall assemblies, required caulk thickness to be installed symmetrically on both sides of wall, flush with wall surface. The Hourly F Ratings and the minimum required caulk thickness are dependent upon a number of parameters, as shown in the following table:Minnesota Mining & Mfg. Co. - Type CP 25WB+* Bearing the UL Classification MarkingUL System #C-AJ-1044PACKING MATERIALCAULKINGMin Flooror WallThickness(Inches)Tube orConduitDiameter(Inches)MaximumAnnularSpace(Inches)MinimumCaulkThickness(Inches)F RatingHours2-1/2 1/2-12 1-3/81/222-1/2 1/2-12 3-1/4124-1/24-1/24-1/24-1/24-1/24-1/25-1/21/2-61/2-121/2-201/2-201/2-1222-301/2-61-3/83-1/4223-1/421-3/81/4(a)1/211121(b)2333334(a) Minimum 2 inch thickness of mineral wool batt insulation required in annular space.(b) Minimum 1 inch thicjness of mineral wool batt insulation required in annular space on both sides of floor or wall assembly. Minimum 1 inch thickness of caulk to be installed flush with each surface of floor or wall assembly.WALL ASSEMBLYRIGID STEEL CONDUITSECTION A-ACAULKINGAANOTES:Fill, Void or Cavity Material* - Caulk - Applied to fill material installed to completely fill annular space between pipe or conduit and gypsum wallboard and with a minimum 1/4 inch diameter bead of caulk applied to perimeter of pipe or conduit at its egress from the wall. Caulk installed symmetrically on both sides of wall assembly. The hourly F Rating of the firestop system is dependent upon the hourly fire rating of the wall assembly in which it is installed, as shown in the following table. The hourly T Rating of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assembly in which it is installed, as tabulated below:Minnesota Mining & Mfg. Co. - Type CP 25WB+* Bearing the UL Classification MarkingUL System #W-L-1001Max Pipeor ConduitDiameter(inches)AnnularSpace(Inches)F RatingHoursT RatingHours10 to 3/161 or 20(b), 1 or 211/4 to 1/23 or 43 or 4446120 to 1/40 to 1-1/2(a)1/4 to 1/23/16 to 3/81 or 21 or 23 or 41 or 20000(a) When copper pipe is used, T Rating os 0 hours.(b) 0 to 1-1/2 inch annular space applies only when Type CP-25 WB+ caulk is used and only when the minimum thickness of the gypsum wallboard is 5/8 inches for 1 hour rated walls and 1-1/4 inches for 2 hour rated walls.CAULKINGPLASTIC JACKETED CABLE THROUGHCONCRETE WALLS AND FLOORSPLASTIC JACKETED CABLE THROUGHGYPSUM WALLSMETAL PIPE THROUGH GYPSUM WALLSMETAL PIPE THROUGH CONCRETEWALLS AND FLOORSFACPAll engineering and installations shall comply with the 2019 CALIFORNIA CODE OF REGULATIONS:• 2019 BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1 TITLE 24 C.C.R.• 2019 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R.• 2019 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R.• 2019 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R.• 2019 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R.• 2019 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24 C.C.R.• 2019 CALIFORNIA REFERENCED STANDARDS CODE, PART 12, TITLE 24 C.C.R.• 2019 CALIFORNIA ENERGY CODE, PART 6, TITLE 24 C.C.R.• 2019 CALIFORNIA ELEVATOR SAFETY CONSTRUCTION CODE, PART 7, TITLE 24 C.C.R.• 2016 EDITION NATIONAL FIRE ALARM AND SIGNALING CODE (NFPA 72)Fire Department inspections area required. Schedule all inspections in advance.1. The following inspections are required for all alarm systems: a. Rough-wire - (cables/conductors, backboxes, conduits, equipment, etc.). b. Alarm system(s) function test - (detectors, control valves, dampers, switches, shutdowns, shunts, recall, duct-smoke detector pressure differential, etc.). c. Secondary power test - (24 hour standby plus 5 minute alarm, voltage drop, emergency generator, etc.).2. PRIOR TO REQUESTING - alarm system function test and or final alarm inspection(s), the installing contractor shall furnish a written statement to the State Fire Marshal stating the system(s) has been installed in accordance with the approved plans and all devices tested in accordance with the manufactures specifications, listings, and the appropriate NFPA Standards.3. Alarm System Design – All fire alarm system plans and specifications shall be developed in accordance with NFPA 72 by persons experienced in the proper design, application, installation, and testing of fire alarm systems. NFPA 724. Alarm System Installation – Installation personnel shall be supervised by persons who are qualified and experienced in the installation, inspection, and testing of fire alarm systems. NFPA 725. The type, locations, and spacing of smoke detectors shall result from an evaluation based on the guidelines detailed in NFPA 72 and Good Engineering Judgment. Conditions to be considered are: a. Ceiling shape and surface b. Ceiling height c. Configuration of contents in the area to be protected d. Burning characteristics of the combustible materials present e. Ventilation f. Ambient environment6. As-Built Drawings – Of the completed fire alarm system shall be provided at the COMPLETION of the work being performed.7. NFPA 72 Record Of Completion (Certificate Of Completion) – Shall be provided after completion of the operational acceptance test. NFPA 729. Smoke detectors shall not be installed until after the construction cleanup of all dust producing and spraying trades has been completed.10. Control Equipment (FACP, RPS, etc,) Protection Only, if wall mounted (warehouse location, etc.) spot type detection only. The detector is to be located 24-inches above the control cabinet (exception: If area protection is provided).11. [CEC 110.2] – Conductors and equipment required or permitted by the code shall be acceptable only if "Approved," "Identified", "Labeled," and "Listed."12. [CEC 760.10] – All fire alarm circuits shall be identified at terminal and junction locations.13. [CEC 110.3] – All conductor/cable/conduit/electrical chase hangers, fasteners, and supports shall be approved to ensure heating effects under normal conditions of use and also under abnormal conditions likely to arise in service.14. [CEC 110.12, 725.7, 760.8] – Electrical equipment shall be installed in a neat and workman like manner. Cables/conductors shall be supported by the building structure in such a manner that the cable/conductor will not be damaged by normal building use.15. [CEC 110.16] – A minimum work space of 30-inches wide shall be maintained clear and unobstructed in front of the electrical equipment i.e., alarm system control panels and equipment, remote power supplies, etc.16. [CEC 110.7] – All wiring shall be so installed that, when completed, the system will be free from short circuits and from grounds other than as required or permitted in Article 250.17. [CEC 760.54(a)1] – Power-limited circuit conductors shall not be placed in any cable compartment, enclosure, outlet box, raceway, or similar fitting containing conductors of electrical light, power, Class 1, or nonpower-limited fire alarm circuit and Communications Circuits unless separated by an approved barrier. Unless Permitted by 760.55(B) Through 760.55(G)18. [CEC 760.55(A), 725.55(A)] – Power-limited fire alarm circuit conductors/cables shall be separated at least 2-inches from conductors of any electric light, power, Class-1, or nonpower-limited fire alarm circuit conductors/cables.19. [CEC 300.11(B)] – Support of conductors/cables, Raceways shall not be used as a means of support for power-limited fire alarm circuit conductors.20. [CEC 300.11(A)] – Wiring located above a nonfire-rated floor/ceiling or roof/ceiling assembly shall not be secured to, or suspended by, the ceiling assembly, including the ceiling supported wires. An independent means of securing and support shall be provided. The suspended ceiling grids shall not support cables, conductors, or raceways.21. [CEC 760.3(D)] – Corrosive, damp, or wet locations shall comply with CEC 110-11, 300-6, 310-9.22. [CEC 760.3] – Where building control circuits (e.g., elevator capture, fan shutdown, smoke/fire dampers, magnetic door control, etc.) are associated with the fire alarm system, the installation shall comply with CEC, Article 725.23. [CEC 300.13] – Conductors in raceways shall be continuous between outlets, boxes, devices, etc. There shall be no splice or tap within a raceway unless permitted by CEC 300-15.24. [CEC 300.14] – At least 6-inches of free conductor shall be left at each outlet, junction, and switch point or the connection of fixtures, or devices.25. [CEC 300.15(A), (B), (C), (D); 760.52(B), 760.30(A)] – A box or conduit body complying with CEC 370-16 and 370-28 shall be installed at each conductor splice connection point, outlet, switch point, junction point, or pull point for the connection of conduit electrical metallic tubing, surface raceway, or other raceways. A box shall be installed at each connection point between any such cable and raceway systems. Fittings and connections shall be used only with the specific wiring methods for which they are designed and listed.26. [CEC 300.16] – Bushings shall be provided in all conduit ends, transitions from box to cable/conductor, etc.27. [CEC 760.30(A)(1), 760.52(B)(1), 334.15(B)] – All surface mounted cables/conductors located within 7-feet of the floor down to 18-inches below grade or subjected to physical damage shall be installed in electrical metal conduit, rigid metal conduit, Schedule-80 PVC rigid nonmetallic conduit. The conduit shall be secured with approved fasteners at intervals not exceeding 18-inches.28. [CEC 334.30] – Nonmetallic Cable Supports - All nonmetallic cables/conductors shall be secured to the building structure with approved fasteners at intervals not exceeding 4-feet and within 12-inches from every cabinet, box, or fitting.29. [CEC 344.30(A), 344.30, 348.30, (nonmetallic conduit refer to Table 347-8)] – All electrical conduit is to be supported every 10-feet and within 3-feet of each outlet box, junction box, conduit body, device box, or other conduit termination.30. [CEC 350.12, 334.15(B)] – Liquidtight metallic flexible conduit (used at PIV, OS&Y devices, etc.) is not permitted where subjected to physical damage. (Based on this requirement, Liquidtight Metallic Flexible Conduit is not permitted to be installed within 18-inches of the finished surface so as to prevent physical damage resulting from landscaping and maintenance equipment. All conduit below 18-inches at these types of appliances are required to be Schedule-80 PVC rigid nonmetallic or rigid metallic conduit.)31. [CEC 350, 760.30(A)] – Liquidtight flexible metal conduit (used at PIV and OS&Y devices, etc.) is to be secured every 18-inches and within 12-inches of each box.32. All wiring, initiating devices, and annunciator panel shall be supervised to the principal point of annunciation (F/A panel to supervise the annunciator panel all circuits and initiating devices).33. Wiring shall not be looped through devices; wire must be cut for in and out.34. Point and common annunciation prohibited. Non-addressable circuit T-tapping is prohibited.35. All devices in the alarm system shall be compatible and installed to manufacturers specifications.36. Audibility of alarm and voice communication shall be not less than 15 DBA above ambient sound, But not less than 75 DBA, throughout area of alarm.37. Areas having more than 2 strobes in the field of view shall be synchronized.38. Smoke Detector and heat detector locations are based on smooth ceiling with maximum height of 10 feet unless otherwise noted.39. Strobe location is based on 10 foot ceiling height and are installed according to NFPA 72 Requirements unless otherwise noted.40. Wall-mounted strobes shall have their entire lens not less than 80 inches above finished floor and no greater than 96 inches above finished floor.41. Strobes in sleeping areas shall be located within 16 feet of pillow and have minimum intensity of 110cd. For strobes located less than 24 inches from ceiling, minimum intensity shall be 177cd.42. Top of action of pull stations shall be mounted at 48 inches above floor level.43. Fire alarm signal shall meet ANSI S3.41, audible emergency evacuation signal (temporal pattern). 44. All exterior electrical junction boxes, outside control valves, and flow switches shall have electrically supervised covers. Tamper proof screws may be used in lieu of electrical supervision, per the 2016 NFPA 72. Tamper proof screws shall be used on this project.45. The fire alarm panel shall be fed from a dedicated power source. The circuit disconnect means shall be provided with a red marking "FIRE ALARM CIRCUIT". The location of the circuit disconnecting means shall be permanently affixed to the fire alarm panel, per the 2016 NFPA 72FPSFACDOCUMENTCABINETFAANACWFVSC75cd30cd75cd135cd185cdEPIVEEC15cdRISER DIAGRAMMOUNTING HEIGHT DETAIL60" ToCenter ofDisplayManual PullStationAudible DeviceMountedNot LessThan80" A.f.f.Not GreaterThan96" A.f.f.AnnunciatorNot Less Than 6"Below CeilingAudio/Visual OrVisual DeviceFloor LineCeiling LineMountedNot LessThan90" A.f.f.48" To Topof ActionFor Ceiling Less Than 80" AFFEntire Lens To Be MountedWithin 6" Below CeilingFACP72" ToTop ofCabinetDead-FrontCabinetPower Supply/Document Box/CommunicatorPROJECT TITLE:0DPGFOR APPROVALSHEET TITLE:FIRE ALARMSYSTEMJOB NO.:DATE:SCALE:DRAWN BY:CHECKED BY:SHEET NO.:SHEETDPG REF. NO.:NO.INIT.REVISIONSDATEDESCRIPTION02/19/2021J-6147J-614702/19/2021DESERT ALARM INC.73168 Highway 111, #204Palm Desert, CA 92260 State Contractors License C-10 #862402Tel.(760) 322-1562 SHADOW ROCK CHURCH46-760 Commerce CourtLa Quinta, CA 922531DPGREVISIONS03/23/2021COVERSHEETFA - 0101 of 02NONETO 120 VACDEDICATEDCIRCUITCELLULARCOMMUNICATIONTO 120 VACDEDICATEDCIRCUITTO 120 VACDEDICATEDCIRCUITFACPFAAZ6VSZ5Z7WFZ4FZ3FZ2PSZ1FACNACC75cdC75cdC75cd135cd110cd75cd135cd185cd185cd185cd185cd75cdPIVEEC15cdC15cdN1-1N1-2N1-3N1-4N1-5N1-6N1-7N1-8N2-1N2-2N3-1N3-2N3-3N3-4KAUDDDDD,COMMCABLESD,AAAAAAAAAAAAAA111APPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST03/30/2021 3:20:39 PMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FA2021-0004 Rev.1Kohl HetrickReason: I am approving this documentContact Info: 760-777-7074Date: 2021.03.30 15:21:51-07'00' FIRE ALARM SYSTEM SEQUENCE OF OPERATIONSREACTIONACTIONMANUALPOWERCELLULARNACMISSING/PRIMARYSMOKEPULLWATERFLOWTAMPERSUPPLYCOMMGROUNDOPENSHORTLOWPOWERSYSTEMDETECTORSTATIONSWITCHSWITCHTROUBLETROUBLEFAULTCIRCUITCIRCUITBATTERYFAILURETROUBLEANNUNCIATE AT FIRE ALARM CONTROL PANEL - ALARMXXXANNUNCIATE AT FIRE ALARM CONTROL PANEL - SUPERVISORYXXXANNUNCIATE AT FIRE ALARM CONTROL PANEL - TROUBLEXXXXXXANNUNCIATE AT REMOTE ANNUNCIATOR - ALARMXXXANNUNCIATE AT REMOTE ANNUNCIATOR - SUPERVISORYXXXANNUNCIATE AT REMOTE ANNUNCIATOR - TROUBLEXXXXXXACTIVATE VISUAL ALARM DEVICESXXXACTIVATE AUDIBLE ALARM DEVICESXXXACTIVATE CENTRAL STATION CONNECTION - ALARMXXXACTIVATE CENTRAL STATION CONNECTION - SUPERVISORYXXXACTIVATE CENTRAL STATION CONNECTION - TROUBLEXXXXXXPROJECT TITLE:0DPGFOR APPROVALSHEET TITLE:FIRE ALARMSYSTEMJOB NO.:DATE:SCALE:DRAWN BY:CHECKED BY:SHEET NO.:SHEETDPG REF. NO.:NO.INIT.REVISIONSDATEDESCRIPTION02/19/2021J-6147J-614702/19/2021DESERT ALARM INC.73168 Highway 111, #204Palm Desert, CA 92260 State Contractors License C-10 #862402Tel.(760) 322-1562 SHADOW ROCK CHURCH46-760 Commerce CourtLa Quinta, CA 922531DPGREVISIONS03/23/2021GROUND FLOORFA - 0202 of 03AS NOTEDNOTIFICATION APPLIANCE CIRCUIT (NAC) LISTCIRCUIT# OFCIRCUITWIREPATHWAYPATHWAYPREFIX#DEVICESDEVICE TYPELOCATIONORIGINIDCLASSSURVIVABILITYN18Horn/StrobeGround FloorP.S.AB0N22Horn/StrobeGround FloorP.S.AB0N34Horn/StrobeMezzanineP.S.AB0N40- -- -P.S.- -B0INITIATING DEVICE CIRCUIT (IDC) LISTZONECIRCUITWIREPATHWAYPATHWAYPREFIX#DEVICE TYPELCOATIONORIGINIDCLASSSURVIVABILITYZ1Smoke DetectorAt FACPFACPDB0Z2Manual Pull StationAt FACPFACPDB0Z3Manual Pull StationMain EntryFACPDB0Z4Waterflow SwitchTo Be VerifiedFACPDB0Z5PIV Tamper SwitchTo Be VerifiedFACPD/UB0Z6Power Supply TroubleAt FACPFACPDB0Z7Cell Comm TroubleAt FACPFACPDB0BATTERY CALCULATIONS FOR FACP - HONEYWELL VISTA-32FBMODELSTANDBYEXTENDEDALARMEXTENDEDQTY.MANUFACTURERNUMBERDESCRIPTIONCURRENTSTANDBYCURRENTALARM1HoneywellVista-32FBFire Alarm Control Panel0.300000.300000.470000.470001Honeywell6160CRFire Alarm Remote Annunicator0.045000.045000.150000.150001System Sensor2W-BSmoke Detector0.000050.000050.130000.13000Panel Voltage:12VDCTotal Standby:0.3451Total Alarm:0.7500Battery Voltage:12VDCHours in Standby:24Minutes in Alarm:5Battery Capacity:17.2Amp HoursStandby AH:8.2812Alarm AH:0.0625De-Rating Factor:20%Number of Batteries:1Total Capacity Used:8.3437Total Battery Capacity:17.2Amp Hours @ Panel VoltageBattery Capacity:17.2000De-Rated Battery Capacity:13.7600Spare Amp Hours:5.4163Spare Amp Hours Percentage:39.36%GROUND FLOORSCALE: 1/8" = 1'SANCTUARY1:12 RAMP SLOPE (MAXIMUM)VANITY MAIN ELECTRICALJANITORSTORAGE STORAGEMEN'S RESTROOMWOMEN'S RESTROOMSTORAGE STORAGESTORAGELOUNGEPRESCHOOLNURSERYMJULIT-PURPOSEROOMTOILETAAAAAA2D,AD,KA2DUU(BY STREET)185cd185cd135cdC75cdC75cdC75cd110cd75cd135cd185cdFAAFFACPDOCUMENTCABINETFACFPSNACWFVSPIVEEEZ1Z2Z3Z6Z7N1-1N1-2N1-3N1-4N1-5N1-6N1-7N1-8N2-1N2-2Z4Z51111111BATTERY CALCULATIONS FOR POWER SUPPLY - ALTRONIX - AL602ULADAMODELSTANDBYEXTENDEDALARMEXTENDEDQTY.MANUFACTURERNUMBERDESCRIPTIONCURRENTSTANDBYCURRENTALARM1AltronixAL602ULADAPower Supply0.0900000.0900000.1750000.1750002System SensorPC2RLHorn/Strobe @ 15cd Ceiling0.0000000.0000000.0710000.1420003System SensorPC2RLHorn/Strobe @ 75cd Ceiling0.0000000.0000000.1430000.4290002System SensorP2RLHorn/Strobe @ 75cd0.0000000.0000000.1210000.2420001System SensorP2RLHorn/Strobe @ 110cd0.0000000.0000000.1620000.1620002System SensorP2RLHorn/Strobe @ 135cd0.0000000.0000000.1960000.3920004System SensorP2RLHorn/Strobe @ 185cd0.0000000.0000000.2450000.980000Panel Voltage:24VDCTotal Standby:0.0900Total Alarm:2.5220Battery Voltage:12VDCHours in Standby:24Minutes in Alarm:5Battery Capacity:7Amp HoursStandby AH:2.1600Alarm AH:0.2102De-Rating Factor:20%Number of Batteries:2Total Capacity Used:2.3702Total Battery Capacity:7Amp Hours @ Panel VoltageBattery Capacity:7.0000De-Rated Battery Capacity:5.6000Spare Amp Hours:3.2298Spare Amp Hours Percentage:57.68%BATTERY CALCULATIONS FOR CELLULAR COMMUNICATOR - TELGUARD TG-7FSMODELSTANDBYEXTENDEDALARMEXTENDEDQTY.MANUFACTURERNUMBERDESCRIPTIONCURRENTSTANDBYCURRENTALARM1TelguardTG-7FSCellular Communicator0.060000.060000.250000.25000Panel Voltage:12VDCTotal Standby:0.0600Total Alarm:0.2500Battery Voltage:12VDCHours in Standby:24Minutes in Alarm:5Battery Capacity:7Amp HoursStandby AH:1.4400Alarm AH:0.0208De-Rating Factor:20%Number of Batteries:1Total Capacity Used:1.4608Total Battery Capacity:7Amp Hours @ Panel VoltageBattery Capacity:7.0000De-Rated Battery Capacity:5.6000Spare Amp Hours:4.1392Spare Amp Hours Percentage:73.91%LOCATIONS OF WATERFLOW SWITCH AND TAMPER SWITCH TO BE VERIFIED IN FIELDWIRE DESCRIPTION TABLEWIRE IDAWGCONDUCTOR TYPETYPEDESCRIPTIONTYPECIRCUIT ORIGIND18Solid18/2 FPLInitiatingIDCFACPU14Stranded2#14 THWNInitiating UndergroundIDCFACPA14Solid14/2 FPLIndicatingNACP.S.K18Solid18/4 FPLKeypadDATAFACPDefinitions:FPLPower-limited fire alarm cable listed as being suitable for general-purpose fire alarm use,with the exception of risers, ducts, plenums, and other space used for environmental airand shall also be listed as being resistant to the spread of fire.FPLRPower-limited fire alarm riser cable listed as being suitable for use in a vertical run in ashaft or from floor to floor and shall also be listed as having fire-resistant characteristicscapable of preventing the carying of fire from floor to floor.THHNThermoplastic High Heat Resistant Nylon Coated Cable.THWNThermoplastic Heat and Water Resistant Nylon Coated Cable.Cable within seven (7) feet of finished floor must be protected from physical damage.Cable above seven (7) feet may be exposed, and supported, unless AHJ requires otherwise.Use Type "THWN" For Wet/ Damp Locations.SYMBOL LEGENDSYMBOLDESCRIPTION Fire Alarm Control Panel Remote Annunciator Power Supply Cellular Communicator Document Cabinet Smoke Detector Manual Pull Station Waterflow Switch EXISTNG PIV Tamper Switch EXISTNG Horn/Strobe @ 15cd Ceiling Horn/Strobe @ 75cd Ceiling Horn/Strobe @ 75cd Horn/Strobe @ 110cd Horn/Strobe @ 135cd Horn/Strobe @ 185cd Fire Bell EXISTINGFACPFPSFACDOCUMENTCABINETFAANACWFVSC75cd30cd75cd135cd185cdEEPIVEC15cd11 PROJECT TITLE:0DPGFOR APPROVALSHEET TITLE:FIRE ALARMSYSTEMJOB NO.:DATE:SCALE:DRAWN BY:CHECKED BY:SHEET NO.:SHEETDPG REF. NO.:NO.INIT.REVISIONSDATEDESCRIPTION02/19/2021J-6147J-614702/19/2021DESERT ALARM INC.73168 Highway 111, #204Palm Desert, CA 92260 State Contractors License C-10 #862402Tel.(760) 322-1562 SHADOW ROCK CHURCH46-760 Commerce CourtLa Quinta, CA 922531DPGREVISIONS03/23/2021MEZZANINEFA - 0303 of 03AS NOTEDMEZZANINESCALE: 1/8" = 1'OPEN AREAOPEN TO BELOWUtility ChaseUtility ChaseStorage4'x4' WIND.4'x4' WIND.4'x4' WIND.4'x4' WIND.4'x4' WIND.4'x4' WIND.42" HIGH RAILINGPRAYER ROOM #4OFFICESOFFICES4'-0"4'-0"4'-0"ATO POWER SUPPLYA75cd185cdC15cdC15cdN3-1N3-2N3-3N3-411VOLTAGE DROP CALCULATIONS FOR NOTIFICATION CIRCUIT: N1Voltage:20.4VDCTemperature:167Fahrenheit =75.0CentigradeWire Gauge (AWG):14AWG =4110Circ Mils =0.00319Ohms/ FootNUMBERCONDUCTOROFLENGTHTOTALAWGCIRCULAROHMSVOLTAGEPERCENTDEVICES(FEET)AMPERESSIZEMILSPER FOOTDROPDROP82501.34901441100.003192.15010.54%Total Voltage Drop2.150VoltsEnd of Line Voltage18.25Total Percentage Voltage Drop in Circuit10.54PercentVOLTAGE DROP CALCULATIONS FOR NOTIFICATION CIRCUIT: N2Voltage:20.4VDCTemperature:167Fahrenheit =75.0CentigradeWire Gauge (AWG):14AWG =4110Circ Mils =0.00319Ohms/ FootNUMBERCONDUCTOROFLENGTHTOTALAWGCIRCULAROHMSVOLTAGEPERCENTDEVICES(FEET)AMPERESSIZEMILSPER FOOTDROPDROP21500.49001441100.003190.4692.30%Total Voltage Drop0.469VoltsEnd of Line Voltage19.931Total Percentage Voltage Drop in Circuit2.30PercentVOLTAGE DROP CALCULATIONS FOR NOTIFICATION CIRCUIT: N3Voltage:20.4VDCTemperature:167Fahrenheit =75.0CentigradeWire Gauge (AWG):14AWG =4110Circ Mils =0.00319Ohms/ FootNUMBERCONDUCTOROFLENGTHTOTALAWGCIRCULAROHMSVOLTAGEPERCENTDEVICES(FEET)AMPERESSIZEMILSPER FOOTDROPDROP41600.50801441100.003190.5182.54%Total Voltage Drop0.518VoltsEnd of Line Voltage19.882Total Percentage Voltage Drop in Circuit2.54PercentWIRE DESCRIPTION TABLEWIRE IDAWGCONDUCTOR TYPETYPEDESCRIPTIONTYPECIRCUIT ORIGIND18Solid18/2 FPLInitiatingIDCFACPU14Stranded2#14 THWNInitiating UndergroundIDCFACPA14Solid14/2 FPLIndicatingNACP.S.K18Solid18/4 FPLKeypadDATAFACPDefinitions:FPLPower-limited fire alarm cable listed as being suitable for general-purpose fire alarm use,with the exception of risers, ducts, plenums, and other space used for environmental airand shall also be listed as being resistant to the spread of fire.FPLRPower-limited fire alarm riser cable listed as being suitable for use in a vertical run in ashaft or from floor to floor and shall also be listed as having fire-resistant characteristicscapable of preventing the carying of fire from floor to floor.THHNThermoplastic High Heat Resistant Nylon Coated Cable.THWNThermoplastic Heat and Water Resistant Nylon Coated Cable.Cable within seven (7) feet of finished floor must be protected from physical damage.Cable above seven (7) feet may be exposed, and supported, unless AHJ requires otherwise.Use Type "THWN" For Wet/ Damp Locations.SYMBOL LEGENDSYMBOLDESCRIPTION Fire Alarm Control Panel Remote Annunciator Power Supply Cellular Communicator Document Cabinet Smoke Detector Manual Pull Station Waterflow Switch EXISTNG PIV Tamper Switch EXISTNG Horn/Strobe @ 15cd Ceiling Horn/Strobe @ 75cd Ceiling Horn/Strobe @ 75cd Horn/Strobe @ 110cd Horn/Strobe @ 135cd Horn/Strobe @ 185cd Fire Bell EXISTINGFACPFPSFACDOCUMENTCABINETFAANACWFVSC75cd30cd75cd135cd185cdEEPIVEC15cd1 Submittal Package for: Shadow Rock Church 46-760 Commerce Court La Quinta, CA 92253 Desert Alarm Inc. 73168 Highway 111, #204 Palm Desert, CA 92260 Contains Cutsheets and CSFM Listings for: Fire Alarm Control Panel Remote Annunciator Cellular Communicator Power Supply Document Cabinet Smoke Detector Manual Pull Station Horn/Strobe Designed to integrate seamlessly with CCTV, access control and a full range of fire and burglary components, Honeywell’s VISTA-32FB provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform can control up to two separate partitions independently, and supports up to 32 zones/points using hardwired, wireless and addressable V-Plex technologies. A diverse line of initiating devices, notification circuits, digital dialers, keypads, RF receivers and relays support this extremely powerful control platform. Advanced technology, combined with simple end-user operation, make the versatile VISTA-32FB the smartest choice for the most demanding applications. • Supports addressable V-Plex access control points using VistaKey (1 to 4 doors) • Supports up to 16 doors of access control using Vista Gateway Module (VGM)* • Supports CCTV applications with the new VistaView-100 CCTV Switcher Module • Identifies the point or zone of a fire using the new FSA-8/FSA-24 Fire System Annunciator • Supports eight hardwired zones, 24 V-Plex addressable points/zones, or 32 wireless points/zones • Can control two separate areas (partitions) independently • Stores up to 512 events and can accommodate 75 user codes • New E2 Software simplifies programming • Easily programmed and maintained with newly upgraded Compass Downloader Software • Automatic smoke detector sensitivity maintenance testing • Commercial UL Wireless Fire and Burg * Connects to Northern Computer’s PassPoint Access Control Systems. Maximum 32 doors. • Notification Appliance Circuits (two): – Programmable – Temporal code compliant – Individually silenceable • Programmable on-board auxiliary relay • SIA false alarm reduction features: – Exit error logic – Exit delay reset – Cross zoning – Call waiting defeat – Recent close report • Supports commercial hardwired, addressable V-Plex polling loop and wireless zones FEATURES VISTA-32FB COMMERCIAL FIRE AND PARTITIONED BURGLARY ALARM PLATFORM VISTA-32FB COMMERCIAL FIRE AND PARTITIONED BURGLARY ALARM PLATFORM • Hardwired zones – Provides nine style B hardwired zones – EOLR supervised for Fire and UL burglary installations – Supports N.O. or N.C. sensors – Individually assignable to one or all eight partitions – Up to 16 two-wire smoke detectors each on zone one and two (32 total) – Up to 50 two-wire glassbreak detectors on zone eight • Patented addressable V-Plex polling loop technology – Supports up to 24 two-wire V-Plex zones/points – Global polling technology for faster processing – Increased current draw capacity (128mA) – Supervised by panel – Individually assignable to partitions, notification circuit (bell) output or aux relay – 4,000 ft capability without the use of shielded cable – Extender/Isolation bus module – Two-wire smoke detector zone/group expansion module adds two or four zones – Eight zone – Class A and B extender module – Eight zone – Class B extender module – One zone supervised contact monitor module • UL Listed wireless expansion – Supports up to 32 wireless zones/points using 5881ENHC Receiver – Supervised by control for check-in signals – Tamper protection for transmitters – Individually assignable up to eight partitions – Supports UL864/NFPA approved wireless smoke detectors • Event reporting • Local printer of access or VISTA related event • Scheduled uploading of events to central station • Up to four doors using VistaKey V-Plex Access Control • Stored events for one call retrieval • Communication – Phone mapping by zone response type – Supports VIP Interactive Phone Voice Module – Panel operation during download – Uploading equipment list to central station – Communication to PassPoint via Vista Gateway Module Applications The VISTA-32FB control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments. Installation The VISTA-32FB alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations. ADDITIONAL FEATURES 9500SN Glassbreak 4101SN Relay Module Notification Appliances 4208U Eight-Zone Expansion Module 4293SN Adapters V-PLEX Loop 5192 Series Smoke Detectors VISTAKey V-Plex Access Control Module 5881ENHC Commercial Wireless Receiver 6160CR Red Alpha Console 4204 Relay Module Eight Class B Hardware Zones 4146 Key Switch Option 4100SM Printer Interface Module 6220S Printer RS232 Phone Line to Central Station 7720ULF Long Range Radio 7845C Cellular Notification Appliances 5140 LED Communicator Status Module VistaView 100 CCTV Switcher 4208SNF Eight-Zone Expansion Module Electrical • Primary power: 18VAC @ 72VA ADEMCO No. 1451 • Quiescent current draw: 300mA • Backup battery: – 12VDC, 7AH min to 34.4AH max – Lead acid battery (gel type) • Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output • Aux. standby pwr: 12VDC, 1A max • Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources • 24 hours with 1A standby load or 60 hours with 205mA max standby load using 34.4AH battery Fusing • Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. Main Dialer • Line seize: Double Pole • Ringer equiv.: 0.7B • Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics Cabinet dimensions • 14.5” H X 12.5” W X 3” D Environmental • Storage temp: 14° to 158°F (-10° to 70°C) • Operating temp: 32° to 122°F (0° to 50°C) • Humidity: 85% RH • EMI: Meets or exceeds the following requirements: – FCC Part 15, Class B Device – FCC Part 68 – IEC EMC Directive Agency Listings • Burglary • FCC Part 15, Class B; FCC Part 68 • UL Residential and Commercial • UL864/NFPA Local Fire • UL864/NFPA Central and Remote Station Fire • UL609 Grad A Local Mercantile Premises/Local • Mercantile Safe and Vault • UL365 police station connected burglar alarm • Grade AA Service (with LRR Model 7920SE) • UL611/UL610 Central Station Burglar Alarm • California State Fire Marshal • FM SPECIFICATIONS 4278EX Quad PIR 4193SN Serial Interface Module 6139R 32 Character Red-Alpha Keypad 4204CF Supervised NAC Module Notification Appliances 5881 Wireless Receiver (Max Two) Supports Up to 32 Conventional Two-Wire Smoke Detectors 4190SN V-Plex Two-Zone Expander 4944SN Addressable Recessed Mount Contact 5808LST Smoke Detectors 5816 Door/Window Miniature Transmitter 5969 Commercial Hold-Up Switch 5817CB Wireless Commercial Transmitter 5808LST Smoke Detectors VGM (PTVGM) VISTA Gateway Module Pass Point 5890 Wireless PIR 5800 Series Wireless Devices Q2260SN Multiplex DUAL TEC Motion Detector 4209U Group Zoning Module Supports Up to 16 Convential Two-Wire Smoke Detectors Manual Pull Stations 5104MPS-1* 5104MPS-2* Tamper Switch* Flow Switch* Low Temp Switch* L/VISTA32FB/D June 2007 © 2007 Honeywell International Inc. Honeywell Security & Custom Electronics Honeywell 2 Corporate Center Drive Melville, NY 11747 www.honeywell.com ORDERING VISTA-32FB Commercial Fire and Partitioned Burglary Alarm Platform VISTA-32FB COMMERCIAL FIRE AND PARTITIONED BURGLARY ALARM PLATFORM Auxiliary devices • 4204 – Relay Module, four form C contacts • 4204CF – Two supervised output circuits • 5140DLM, Supervised Dialer • 5881 Series – RF Receiver supporting 5800 wireless detectors • 6160CR – Red Alpha Keypad • 6139R – Red Alpha Keypad/annunciator • 6220S – System printer used with 4100SM serial module • FSA-8, FSA-24 Fire Annunciators Two-wire smoke detectors conventional • System Sensor smoke detectors Horn/Strobes • System Sensor Notification Appliances Manual Pull Stations • 5140MPS-1 • 5140MPS-2 V-Plex (addressable) Devices • 4101SN Relay Zone Module • 4190SN Remote Point Module – two zones • 4190WH • 4193SN Two Zone Serial Interface Module • 4208U Loop Expansion Module – eight zones • 4208SNF Eight Zone/2 Class A/6 Class B Expander Module • 4209U Group Zoning Module – two/four zones • 4293SN One Zone Serial Interface Module • 4297 Isolation/Extender Module CCTV • VistaView-100-CCTV Switcher Module V-Plex (addressable) Smoke Detectors • 5192SD • 5192SDT VISTA Interactive Phone Module • 4286 Voice Module Passive Infrared Detectors • 998MX • 4275EX-SN • 4278EX-SN • QUEST2260SN V-Plex (addressable) Contacts • 4194WH, 4193SN • 4939SN-WH • 4944SN-WH • 4959SN Glassbreak Detectors • 9500SN Long Range Radio • 7720ULF • 7845C Cellular Radio Upgraded software • Upgraded Compass Downloader Windows compatible Wireless Devices • 5804 – Wireless Key • 5804BDV – Bi-Directional Wireless Key with Voice • 5804BD – Bi-Directional Wireless Key • 5808C - Wireless Smoke Detector • 5816 – Door/Window Transmitter • 5819 – Shock Sensor • 5827BD – Bi-Directional Keypad • 5849 – Glassbreak Detector • 5890 – PIR Access Control • VistaKey V-Plex (addressable) Access Control • VistaKey-SK Starter Kit • VistaKey-EX Expansion Kit • VGM VISTA Gateway Module to PassPoint Access Control (Northern Computers) Commercial Wireless Devices • 5808LST - Wireless Smoke Detector • 5809 - Wireless Heat Detector • 5817CB - Wireless Commercial Transmitter • 5869 - Hold-Up Transmitter • 5881ENHC - Commercial Fire/Burg Receiver SPECIFICATIONS CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7165-1645:0123 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE:ADEMCO INC.2 Corporate Center Drive, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@resideo.com DESIGN: Models FA1600C, FA1670C, FA1700C, Vista-100, Vista-128FB, Vista-128FBP, Vista-250FBP, and Vista-32FB fire alarm control units. Power-limited. Automatic, manual, noncoded, local, remote station, central station, waterflow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. Minimum system components: Vista 100, Vista-128FB, -32FB; Control Unit 1451 Transformer 6137, 6137-R, 6139, 6139-R Keypad *COM-UL Enclosure *6160CR-2 Alpha Keypad (for use with Vista series) *FA570CR Alpha Keypad (for use with First Alert series) *ECP Isolator *4146 Keyswitch *5140 DLM Backup Dialer Module *7845i-ENT Internet Communicator *4208U 8 Zone Remote Zone Expander *4208SNF 8 Zone V-Plex Class A Adapter *Vplex VSI Short Isolator *4204CF Supervised *4190SN 2 Zone Expansion Module *4193 Serial Number Interface Module *4297 Polling Loop Extender *5881ENHC, 5883-H Short Range RF Receiver RATING:Primary 120 VAC, 18 VAC Secondary, 12 VDC Standby INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to *Rev. 01-07-11 BH July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Listing No. Page 2 of 2 7165-1645:0123 manufacturer’s Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification, the maximum Retard /Reset/Restart period shall not exceed 30.0 seconds. 2. Burglary and other non-fire functions were not examined. 3. Formerly 7165-0078:174 4. Changed company name and number to 2011 and Honeywell Security. 9-08-10. FM *Rev. 01-07-11 BH July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Commercial Fire Alpha Keypad 6160CR The 6160CR is an addressable remote keypad intended for use in commercial fire applications with ADEMCO’s control platforms. The keys are continuously backlit for convenience and easy visibility. The LCD display is backlit only when a key is depressed*, or when the system is in alarm or trouble condition. *Note: On some platforms, the LCD may be programmed to remain on at all times (see panel instructions for details). • Four programmable function keys • Built-in sounder • Four LED’s – Armed – Ready – Trouble – Supervisory • Large easy-to-read display • Red removable door FEATURES Honeywell Security Group ADEMCO 165 Eileen Way, Syosset, NY 11791 www.ademco.com Copyright ©2003 Honeywell International Inc. L/6160CR/D 9/03 Physical: • 5.250” W x 7.437” H x 1.312” D Display: • Alphanumeric, 32-character (2 lines x 16 characters) LCD back light LEDs: ARMED (red), READY (green), *TROUBLE (yellow) and *SUPERVISORY (yellow) • See control panel’s instructions for specific applications regarding Trouble and Supervisory LEDs. Sounder: • High-quality speaker Electrical: • 45mA standby 150mA in alarm (sounder, back light and LED on) Wiring table: (all keypads) SPECIFICATIONS Compatibility Supports Control Platforms: • VISTA-32FB Rev. 3 and higher • VISTA-128FB Rev. 4 and higher • VISTA-128FBP • VISTA-250FBP • V128FBP-24 • V250FBP-24 DI “Data IN” to control panel from keypad –Ground (-aux. Power) ++12VDC (+aux. Power) DO “Data OUT” from control panel to keypad 6160CR Commercial Fire Alpha Keypad ORDERING UL/CUL Listed for Residential and Commercial Fire and Burg installations. To be employed with manufacturer’s listed control units as indicated in the installation instructions. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7300-1645:0115 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:ADEMCO INC.2 Corporate Center Drive, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@resideo.com DESIGN: Models 6139, 6139R, 6160VADT, 6160V, 6270, 6270ADT, FA700KP, 6160CR, 6150V, 6150VADT, CP150KP, FA560VKP, FA6150KP-GP, 6160VBAY, 6164, 6164SP, 8132i, 8142i, FA800KPi, FA850Kpi, 6270PL2, 6271V, 6271VADT, FA270VKP, FA570VKP, FA270KP, FA570KP, FA574KP, 6271C, 6271CV, FA701CKP, FA701CVKP, FA701VKP, FA570CR, 6160CR-2, 6164US, FA271KP, 6149EX, 6165EX remote keypads, 4146 keyswitch, and *6280S, *6280W, *TUXS, *TUXW touchscreen keypads. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, UL and ETL label. APPROVAL: Listed as remote keypads for use with listee's separately listed compatible fire alarm control units. Refer to listee’s installation Instruction Manual for details. rev. 09-23-11 mt July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. TG-7FS Cellular alarM CoMMuniCator for 3g/4g networks Telguard Cellular Service Telguard Cellular Service provides nationwide digital cellular network coverage for all Telguard units. Telguard’s Communication Center is UL compliant and provides seamless connectivity between the alarm panel, the Telguard family of products and the central station. Telguard Technical Support provides a single point of contact for both cellular service and Telguard product questions. Advanced Reliability • Features the ability to utilize multiple cellular technologies to increase availability and reduce false alarms. • Automatic self-tests with central station notification ensure the cellular system is operating. • Available relay output for tripping the alarm control panel when a trouble condition occurs. Telguard Online Telguard makes adopting cellular easy with a secure Internet portal. The straightforward web interface allows security dealers and central stations to quickly and efficiently access Telguard based services 24/7. This advanced tool has multi-level user authorization and provides total account management of UL Listed Telguard cellular alarm communicators. PRODUCT FEATURES Meets UL 864 requirements for sole, primary or backup path communications. Provides RMR protection by leveraging technology that operates on 3G/4G networks. Supports listen-in, two-way voice verification over cellular. Minimizes false alarms by providing dual paths for self-tests. Falls back to 2G (GSM) if a 3G/4G network isn’t available. COmmERCiAl FiRE The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS because of the new sixty minute supervision mode. The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. TG-7FS Cellular alarM CoMMuniCator for 3g/4g networks Telguard, a Division of Telular Corporation • Cumberland Center IV • 3225 Cumberland Blvd • Suite 300 • Atlanta, GA 30339 • USA 800-229-2326, Option 5 • www.Telguard.com • Copyright ©2012 Telular Corporation • All Rights Reserved Radio Transceiver • 3G cellular radio. • GSM 850MHz: Class 4 (2 watts). • GSM 1900MHz: Class 1 (1 watt). • UMTS WCDMA FDD 850/1900MHz. • Antenna: 9” dipole with 2dBi gain, 12 ft of cable and universal mounting bracket. • FCC part 15, 22, 24 and 68 compliant. Physical Details • TG-7FS: 7.5” H x 11.5” W x 3.5” D. • Shipping Weight: 8lbs. • Operating Environment: 0°C to +50°C; up to 95% humidity (non-condensing). Standard Features • Full data reporting. • Automatic self-test (60 min. & daily). • Power supply with battery harness. • Locking, red metal enclosure. • Two programmable supervisory trip outputs. • Alarm format support for SIA2, Contact ID, pulse (3x1, 4x2), modem IIe, & IIIa2 , DMP. • Telephone line monitor built-in, with Standard Line Security. Power • Transmit power: 1.0W-2.0W (maximum allowable). • Power Consumption: 60mA (Standby) 250mA (Transmission). • Transformer: 12VAC, 800mA UL listed plug-in. Ul listings Commercial Fire 864 • Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 122012RevB Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories • ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. • HGD-0: High gain directional antenna. • EXD-0: External antenna. * For the most current product specifications and UL Listings visit www.Telguard.com. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7300-1402:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com DESIGN: Models *TG7LV001, *TG7LVA01, *TG7LVF01 and TG-KIT digital cellular communicator system. Models are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING:120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee’s Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *04-07-2017 dcc July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. • 24VDC rated @ 6.5 amp max. • Two (2) Class A or four (4) Class B outputs. • Two (2) Class A or two (2) Class B FACP inputs. • Two (2) Class A or four (4) Class B indicating circuits. • Two (2) Class B outputs may be paralleled for more power on an indicating circuit. • One (1) Aux. Power Output @ 1 amp supply current (w/battery back up). • Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LED’s indicate a prior fault (short, open, ground) has occurred on one or more signaling circuit outputs. • 2-wire Horn/Strobe Sync mode allows audible notification appliances (Horns) to be silenced while visual notification appliances (Strobes) continue to operate. • Horn/Strobe sync protocols include: CooperWheelock®, Gentex®, System Sensor®, Faraday, Amseco. • Temporal Code 3 Mode. • Steady Mode. • Input to Output Follower Mode (maintains synchronization of notification appliance circuits). • March Time. • Compatible with 12VDC or 24VDC fire panels. • Common trouble inputs and outputs. • Ground fault detection. • Input 115VAC. • AC fail supervision (form “C” contacts). • Low battery supervision (form “C” contacts). • Battery presence supervision (form “C” contacts). • Power supply, logic board, red enclosure, cam lock, transformer & battery leads. • Enclosure: - Combination knockouts are 1/2” and 3/4” - Accommodates up to two (2) 12VDC/12AH batteries. AL602ULADA weights: Product weight: 9.6 lbs. Shipping weight: 12.3 lbs. AL602ULADA NAC Power Extenders Rev. AL602ULADA_A25K Overview Specifications Agency Approvals UL Listed Control Units and Accessories for Fire Alarm Systems (UL 864) Ninth Edition Factory Mutual Approved.NYC Department of Buildings Approved. California State Fire Marshal Approved. The AL602ULADA are extremely cost effective voltage regulated remote NAC Power Extenders. They may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to sup- port system accessories. CooperWheelock is a registered trademark of CooperWheelock. Gentex is a registered trademark of Gentex Corporation. System Sensor is a registered trademark of Honeywell. Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com Enclosure Dimensions AL602ULADA: 15.5”H x 12.23”W x 4.5”D 12.230" 15.500" 1.100" 0.910" 1.100" 0.910" 0.790" 1.100" 1.500" 1.250" 5.000" 1.250" 1.500"4.615"4.615"1.500" 1.750" 1.500"4.615"4.615"1.500" 1.750" 4.500"4.500" 1.250" 1.500" 5.000" 2.000" 2.000" 1.250" 1.375" 1.125" CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7315-1335:0103 Page 1 of 1 CATEGORY: 7315 -- POWER UNITS LISTEE:Altronix140 - 58th Street, Bldg A-3W, Brooklyn, NY 11220 Contact: Gary Zatz (718) 567-8181 Fax (718) 567-9056 Email: garyz@altronix.com DESIGN: Models AL500UL-ADA and AL600UL-ADA,*AL602-UL-ADA Power-limited Indicating Circuit Power Supply. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:AL500UL-ADA: 120 VAC input, 12/24 VDC output, 4A AL600UL-ADA: 120 VAC input, 12/24 VDC output, 6A *AL602UL-ADA:115 VAC input, 12/24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a power-limited indicating circuit power supply for use with separately listed compatible fire alarm control units and indicating devices. Authority having jurisdiction should be consulted prior to installation. *REV. 09-06-2002 TR July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. SRD ACE-11 System Record Documents FEATURES • 18 gauge cold rolled steel construction with red powder coat and white lettering • Dimensions are 12” wide x 13” tall and 2 1/4” deep • Stainless steel piano hinge • Two key ring hooks to hold system keys • Business card holder for key contacts • Slide tab allows user to select USB-C or Micro USB connector to download from 8GB digital flash memory • DCD Computer Desk Kit (sold separately) holds enclosure door open at a 90 degree angle with a snap on cable for a convenient working surface in the field. Includes velcro strap for securing your laptop. Store important system documents in a secure location with a cabinet built specifically to meet the requirements of NFPA 72 7.7.2.4. The number one goal at Space Age is to manufacture code compliant solutions, and the SRD is just that. NFPA 72 7.7.2.1 states, “With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises.” The SRD includes our innovative 8GB flash drive slide tab that allows the user to select a USB-C or Micro USB connector to access records electronically (See NFPA 72 7.5.6.7). SPECIFICATIONS The SRD System Record Documents Box shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a powder coat finish. The cover shall be permanently screed with 1” high lettering “SYSTEM RECORD DOCUMENTS” with white indelible ink. The access door shall be locked with a 3/4” barrel lock and there will be a 12” stainless steel piano hinge. The SRD will have a minimum of 8 gigabyte digital flash memory drive with a slide tab that allows user to select USB-C or Micro USB connector for uploading and downloading information. The enclosure will supply 4 mounting holes. Inside will accommodate standard 8 1/2” x 11” manuals and document records. A legend sheet will be attached to the door for system required documentation, key contacts and system information. The enclosure shall also provide 2 key ring holders with a location to mount standard business cards for key contact personnel. CUSTOM COLORS AND BRANDING AVAILABLE Pg. 1/2 ORDERING INFORMATION P/N# SSU00689 SRD System Record Documents Box - Red P/N# SSU00690 SRD System Record Documents Box - Red with your custom screened logo P/N# SSU01689 SRD System Record Documents Box - Black P/N# SSU01690 SRD System Record Documents Box - Black with your custom screened logo P/N# SSU00616 DCD Computer Desk Kit www.1sae.com | toll free 1.800.486.1723 | fax 508.485.4740 © Copyright 2018 Space Age Electronics, Inc. | This document subject to change without notice | LT10641 | Rev. E Pg. 2/2 DIMENSIONS CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7300-0553:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@1sae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IF1, IFX/A and IFX/D enclosures. Models ACE-11, ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee’s Installation Instruction Manual for details. 02-09-16 dc July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Agency Listings Photoelectric Smoke Detectors System Sensor i3™ series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included• Large wire entry port• In-line terminals with SEMS screws• Mounts to octagonal and single-gang back boxes, 4-square back • boxes, or direct to ceiling Stop-Drop ’N Lock attachment to base• Removable detector cover and chamber• Built-in remote maintenance signaling• Drift compensation and smoothing algorithms• Simplified sensitivity measurement • Wide-angle, dual-color LED indication• Loop testing via EZ Walk feature• Built-in test switch• Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop ’N Lock™ action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector’s condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. 2093290-01-E7272-1653:1523011446S911 3180932 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0318-007 • 6/09 • #2169 Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number_______, listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 3½-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5 V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 µA maximum average; 4-wire: 50 µA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24 V Peak Standby Current 2-wire: 100 µA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30 V AC/DC Physical Specifications Dimensions (including base)5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 3½-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby)Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE:System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING:8.5 - 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/min. NOTE: Formerly 7272-1209:210 06-20-05 July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. OperationThe single-action pull-station isactivated by a single pull-down ofthe alarm handle. The dual-actionversions require pushing in thehandle, then pulling the handledown for activation. The PS-DA/PS-SA manual pull stations areULlisted and meet the ADArequirement of a 5-lbs. maximumpull force to activate. Operatinginstructions are molded into thehandle along with Braille text.Molded terminal numbers can befound adjacent to the wiring termi-nals.Models:PS-SA–Single action with ‘pigtail’connections and a key lock reset.Pigtail wires are provided for con-nection to the Fire Alarm ControlPanel’s (FACP) initiation circuit.PS-DA –Dual action model withscrew terminal connections and akey lock reset.PS-DAH –Same as PS-DA exceptwith hex lock reset. PS-DALOB –Same as PS-DA with“outdoor use” listing. Includes SB-I/O backbox and sealing gasket. PS-DASP –Same as PS-DAexcept with both English andSpanish operating instructions.Features:• UL Listed• CSFM Listed• Meets ADA requirements• Operating instructions are mold-ed into the handle along withBraille text.• Made of durable Lexan• Available in Spanish• Key resettable• Easy to Install and operate• Single or dual action•Surface mount box available Specification:Dimensions:Height: 5-1/2” (13.97 cm)Width: 4” (10.16 cm)Depth:1-7/16” (3.65 cm)Operatingtemperature:32°F to 120°F(0°C to 49°C)Electrical:Switch ContactRating: 0.25 A @ 30 VAC or VDCAccessories:SB-I/O Surface Mount Back-boxBG-TR Trim Ring PS-DA and PS-SAConventional Pull-stations The PS-DA/PS-SA Pull Stations are non-coded manual pull stations whichprovide a Fire Alarm Control Panel (FACP) with a single alarm initiatinginput signal. The PS-DA/PS-SA pull stations includes both single-action anddual-action models equipped with key lock / reset. It was designed to meetmultiple applications with the installer and end-user in mind. Its innovative design, durable construction, and mul-tiple mounting options make the PS-DA and PS-SA simple to install, maintain, and operate. Easy to Install and Operate PS-DA PS-DASP CONVENTIONAL FIRE CONTROL PANEL ACCESSORY CONVENTIONAL FIRE CONTROL PANEL ACCESSORY PS-DA and PS-SAConventional Pull-Stations Engineering Specification Manual Fire Alarm Stations shall be non-code, with a key-operated reset lock in order that they may be tested,and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of akey. An operated station shall automatically condition itself so as to be visually detected as activated. Manualstations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operatinginstructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching back-box SB-10; orsemi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shallbe installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local require-ments. Manual Stations shall be Underwriters Laboratories listed.*NOTE:The words “FIRE/FUEGO” on the PS-DASP shall appear on the front of the station in white letters,approximately 3/4" high. PS-SA Front View PS-DA Front View PS-SA Rear View PS-DA Rear View MADE IN AMERICA P/N 350241 Rev.C©2009 Honeywell International Inc. This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications are sub-ject to change without notice. For more information, contact Silent Knight 12Clintonville Road Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7150-0559:0140 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE:SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models PS-SA, PS-DA, PS-DASP and IDP-PULL-DA fire alarm pull boxes. The PS series followed by SA or DA is a single action or dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF:7150-0028:0199 *Updated 09-08-09 fm July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383, 3057072 Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 × 4 × 17⁄8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411 ⁄16 × 411 ⁄16 × 21 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1,2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 1.91˝ D (143 mm L × 119 mm W × 49 mm D) Compact Wall-Mount Dimensions (including lens)5.26” L x 3.46” W x 1.91” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.25˝ D (143 mm L × 119 mm W × 32 mm D) Compact Horn Dimensions 5.25” L x 3.45” W x 1.25” D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9*Coded High 85 90 90 10*3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Candela Range (15–115 cd) DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Current Draw Data Horn Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86503 • 03/17 L-Series Dimensions Model Description Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT L-Series Ordering Information Notes: All -P models have a plain housing (no “FIRE” marking on cover) All -SP models have “FUEGO” marking on cover All -ALERT models have “ALERT” marking on cover Compact Strobe / Horn Strobe Strobe / Horn Strobe Compact Horn Horn Model Description Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383 AVDS868-02 • 12/01/2017 • Page 3 AVDS868-02 • 12/01/2017 • Page 2 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11 ⁄16 × 4 11 ⁄16 × 2 1 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3)8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02 • 12/01/2017 • Page 3 Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 UL Current Draw Data Horn Strobe Tones and Sound Output Data UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), Ceiling Horn Strobe, Candela Range (15–177 cd) DC Input 8–17.5 Volts 16–33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16–33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS868-02 • 12/01/2017 L-Series Dimensions Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White L-Series Ordering Information Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Model Description Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 6.83" diam. (173 mm) 2.47" (62.7 mm) 1.37" (34.8 mm)6.92" diam. (175.77 mm) 2.5" (64 mm) 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box A0531-01 A0545-00 A0546-00 A0494-01 For a ceiling-listed horn-only device, see AVDS865 “Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications”. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7135-1653:0503 Page 1 of 2 CATEGORY: 7135 -- AUDIBLE DEVICES LISTEE:System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: System Sensor Indoor 2-wire and *4-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR-2 and *TR-2W CeilingTrim Rings: *TRC-2 and *TRC-2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Listing No. Page 2 of 2 7135-1653:0503 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING:12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee’s Installation Instruction Manual for details. Revision 08-21-2017 dcc July 01, 2020Date Issued:Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org March 10, 2021 Desert Alarm INC 73168 Highway 111 #204 Palm Desert, CA 92260 Re: Fire Alarm System Plan Review – SHADOW ROCK CHURCH FA2021-0004 / 46760 COMMERCE CT, LA QUINTA, CA 92253 The fire alarm system plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Function Test / Start 24-hour Battery - The alarm installer shall provide all needed testing equipment to complete the final alarm inspection. c) 5-Minute Ring-out / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 46760 COMMERCE CT PERMIT#: FA2021-0004 DATE ISSUED: 3/10/2021 DESCRIPTION: SHADOW ROCK CHURCH CONTRACTOR: DESERT ALARM INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.