Loading...
FA2021-0009ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT A D T COMMERCIAL LLC PO BOX 310702 BOCA RATON FL 33431 (714)685-8120 jjlewis@adt.com BILL TO ADT Commercial LLC 25809 Business Center Drive Ste F Redlands CA 92374 (714)685-8120 jjlewis@adt.com CONTRACTOR A D T COMMERCIAL LLC 25809 Business Center Drive Ste F Redlands CA 92374 (714)685-8120 jjlewis@adt.com OWNER MASTEK 3856 VIA DOLCE MARINA DEL REY CA 92253 (714)685-8120 CONDITIONS Description: PETSMART / INSTALL SOLE PATH COMMUNICATOR TO EXISTING Type: FIRE ALARM (WEB)Subtype: COMMERCIAL - SPRINKLER MONITORING Status: FINALED Applied: 10/26/2021 ECON Parcel No: 600340024 Site Address: 79375 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 11/10/2021 KHET Subdivision: PM 30420 Block: Lot: 5 Issued: 11/11/2021 AHI Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 11/29/2021 KHET Valuation: $1,200.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Thursday, February 23, 2023 3:59:43 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2021-0009 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FUNCTION TEST KHET 11/29/2021 11/29/2021 APPROVED Final clearance is pending correct Record of Completion. FIRE FINAL**KHET 11/29/2021 11/29/2021 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 10/26/2021 11/9/2021 11/10/2021 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 10/26/2021 10/27/2021 10/27/2021 COMPLETE PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS 101-0000-42421 0 $167.00 $167.00 11/11/21 WEB9859 633557795 61 CREDIT 1065604 ECON FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS PC 101-0000-42420 0 $250.00 $250.00 11/11/21 WEB9859 633557795 61 CREDIT 1065604 ECON Total Paid for FIRE FEES: $417.00 $417.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 11/11/21 WEB9859 633557795 61 CREDIT 1065604 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 11/11/21 WEB9859 633557795 61 CREDIT 1065604 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$433.00 $433.00 Printed: Thursday, February 23, 2023 3:59:43 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2021-0009 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/26/2021 Etrakit Contractor 1ST SUBMITTAL PLANS PetSmart 1230 Communicator Conversion Drawings.pdf 1 DOC 10/26/2021 Etrakit Contractor 1ST SUBMITTAL SCOPE PetSmart 1230 Communicator Conversion SOW.pdf 1 DOC 10/26/2021 Etrakit Contractor 1ST SUBMITTAL SPEC SHEETS Petsmart Cellular Conversion Cutsheets.pdf 1 DOC 11/10/2021 KOHL HETRICK FA2021-0009 - APPROVED PLANS.pdf FA2021-0009 - APPROVED PLANS.pdf 1 DOC 11/10/2021 KOHL HETRICK FA2021-0009 - COA AND JOB CARD.pdf FA2021-0009 - COA AND JOB CARD.pdf 1 DOC 11/29/2021 KOHL HETRICK 11-29-2021 FA REC OF COMP.pdf 11-29-2021 FA REC OF COMP.pdf 1 BOND INFORMATION Printed: Thursday, February 23, 2023 3:59:43 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2021-0009 :HEDGWFRPFRPPHUFLDOBBBBBBBBB35(3$5('%<352-(&712'$7(&+(&.('%<5(9,6,216'$7(12 5(9,6,21352-(&70$1$*(5Š%<%<%<%<352-(&7/2&$7,21),5($/$506<67(0BBB)7)7)7)7)7)7  6&$/(&86720(53(760$5717+$9(18(3+2(1,;$5,=21$%8,/',1*,1)250$7,217KLVILUHDODUPVKRSGUDZLQJZDVSUHSDUHGIRUHTXLSPHQWDSSOLFDWLRQRQO\7KHLQIRUPDWLRQFRQWDLQHGKHUHLQLVLQWHQGHGWRDLGLQWKHLQVWDOODWLRQRIWKLVV\VWHP1RGHVLJQFKDQJHVKDYHEHHQPDGHWRWKHHQJLQHHURIUHFRUG VFRQWUDFWGRFXPHQWV6LJQHG'DWHG1,&(7),5($/$506<67(061,&(7/(9(/,,, Andrew W Evans$QGUHZ:(YDQVMMCONTRACTORC-1065604LExp. 05/31/2022S AT FACETODLC-10OCICSNEEIRIOFNAEDTAAICRLLLC&216758&7,217<3(2&&83$1&<7<3(6725,(6 ,16&23(727$/64)7,16&23((;,67,1*),5($/$506<67(0%8,/',1*)8//<635,1./(5(',,,%06<(6<(6&2'(6$'237('%<&$/,)251,$$+-&DOLIRUQLD%XLOGLQJ&RGH 9RO  &DOLIRUQLD([LVWLQJ%XLOGLQJ&RGH&DOLIRUQLD)LUH&RGH&DOLIRUQLD0HFKDQLFDO&RGHADT COMMERCIAL #6689825809 BUSINESS CENTER DRSUITE FREDLANDS CA 92374SA#891115934DR#34837JOB#280681893PETSMART #123079 375 Hwy 111La Quinta CA 92253NSEWNWNESESWSite Map2NTSPETSMART #123079 375 Hwy 111La Quinta CA 92253DEVICE LEGENDDEVICE SYMBOLQTY.MANUFACTURER PART NO. DESCRIPTION CSFM LISTING1 EXISTINGD7024FACP EXISTING1 BOSCH B444STAND ALONE SOLE PATHCELLULAR COMMUNICATOR7300-1615:05021BOSCH B4657300-1615:0253FACPFAC1. INSTALLATION OF BOSCH CELLULAR STAND ALONE SOLE PATH COMMUNICATOR,(B444/B465) TO AN EXISTING APPROVED FIRE ALARM SYSTEMS LOCATED IN ANEXISTING COMMERCIAL RETAIL SPACE.2. PURPOSE OF THE INSTALLATION IS TO CONVERT SERVICE AND MONITORING OFEXISTING FIRE ALARM SYSTEM.3. ALL SIGNALS TRANSMITTED VIA SOLE PATH CELL UNIT IN COMPLIANCE WITH NFPA72.4. ALL DEVICES TO BE TESTED AND INSPECTED IN COMPLIANCE WITH NFPA 72.DEFICIENCIES DOCUMENTED AND REPORTS DISTRIBUTED TO CUSTOMER, AHJ ANDLEFT ONSITE WITH FACP DOCUMENTS.SCOPE OF WORK4.2.SOLE PATH CELLULAR COMMUNICATOR INSTALLATION AND SIGNALVERIFICATION TO BE PERFORMED ACCORDING TO THE MANUFACTURERSINSTRUCTIONS.SOLE PATH CELLULAR SIGNAL STRENGTH SHALL MEET MANUFACTURERSMINIMUM REQUIREMENTS.3.1.ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ANDAVAILABLE FOR FINAL INSPECTION.GENERAL NOTES6+((77,7/(7KLVGRFXPHQWPDWHULDOVRUSUHVHQWDWLRQZKHWKHURIIHUHGRQOLQHRUSUHVHQWHGLQKDUGFRS\ ę$'7,QIRUPDWLRQDO7RROVĚ LVIRULQIRUPDWLRQDOSXUSRVHVRQO\$'73529,'(67+(6($'7,1)250$7,21$/722/6ę$6,6Ě:,7+287:$55$17<2)$1<.,1'(,7+(5(;35(6625,03/,(',1&/8',1*%87127/,0,7('727+(,03/,(':$55$17,(62)0(5&+$17$%,/,7<25),71(66)25$3$57,&8/$5385326(7KH$'7,QIRUPDWLRQDO7RROVFRQWDLQ$'7SURSULHWDU\DQGFRQILGHQWLDOPDWHULDOV1RSDUWRIWKH$'7,QIRUPDWLRQDO7RROVPD\EHPRGLILHGDOWHUHGUHSURGXFHGVWRUHGLQRULQWURGXFHGLQWRDUHWULHYDOV\VWHPRUWUDQVPLWWHGLQDQ\IRUPRUE\DQ\PHDQV HOHFWURQLFPHFKDQLFDOSKRWRFRS\LQJUHFRUGLQJRURWKHUZLVH ZLWKRXWWKHSULRUZULWWHQSHUPLVVLRQRI$'7H[FHSWDVRWKHUZLVHSHUPLWWHGE\ODZ3ULRUWRSXEOLFDWLRQUHDVRQDEOHHIIRUWZDVPDGHWRYDOLGDWHWKLVLQIRUPDWLRQ7KH$'7,QIRUPDWLRQ7RROVPD\LQFOXGHWHFKQLFDOLQDFFXUDFLHVRUW\SRJUDSKLFDOHUURUV$FWXDOVDYLQJVRUUHVXOWVDFKLHYHGPD\EHGLIIHUHQWIURPWKRVHRXWOLQHGLQWKH$'7,QIRUPDWLRQDO7RROV7KHUHFLSLHQWVKDOOQRWDOWHURUUHPRYHDQ\SDUWRIWKLVVWDWHPHQWSYSTEM HAS A SURVIVABILITY LEVEL OF 0 PER NFPA 72.&29(55(6(59(')25$+-)$5.SYSTEM SHALL BE MONITORED BY UL LISTED CENTRAL STATION.TABLE OF CONTENTSPAGE TITLE CONTENTSFA0CoverSITE LOCATION INFORMATION AND SCOPE OFWORKFA1&(//8/$5$'',7,21FLOOR PLAN AND RISER DIAGRAMSCALE:SYSTEM MATRIXN.T.S.SYSTEM INPUTSSYSTEM OUTPUTSMANUAL PULL STATIONSMOKE DETECTORSIN-DUCT SMOKE DETECTORSFIRE ALARM AC POWER FAILUREFIRE ALARM SYSTEM LOW BATTERYOPEN CIRCUITGROUND FAULTNOTIFICATION APPLIANCE CIRCUIT SHORTACTUATE COMMON ALARM SIGNAL INDICATORACTUATE AUDIBLE ALARM SIGNALACTUATE COMMON SUPERVISORY SIGNAL INDICATORACTUATE AUDIBLE SUPERVISORY SIGNALACTUATE COMMON TROUBLE SIGNAL INDICATORACTUATE AUDIBLE COMMON TROUBLE SIGNALACTUATE NOTIFICATION DEVICES DISPLAY/PRINT CHANGE OF STATUSCONTROL UNITANNUNCIATIONTRANSMIT FIRE ALARM SIGNAL TO SUPERVISING STATIONTRANSMIT SUPERVISORY SIGNAL TO SUPERVISING STATIONTRANSMIT TROUBLE SIGNAL TO SUPERVISING STATIONHVAC SHUTDOWN PROCESSNOTIFICATIONREQUIRED FIRESAFETY CONTROLSUPPLE-MENTARYABCDEFGHI JKLMNOP12345678910WATERFLOWSPRINKLER CONTROL VALVEI-INDIVIDUAL HVAC SHUTDOWN1112131415161718192021ABCDEFGHI JKL123456789101112131415161718192021CELLULAR COMMUNICATOR FAULTCENTRAL STATION SYSTEM.MONITORED BY:U.L. LISTED MONITORING STATIONADT LLC dba Protection 14221 W. John Carpenter Fwy.Irving, TX 75063PHONE: 877-776-1911RIVERSIDE COUNTY FIRE DEPARTMENT NOTES__________________________________________________________________________Fire Alarm, Water Flow Alarm & Signaling SystemsFirst complete the bottom portion and then copy the notes on the plans1. The applicable codes and standards are the 2019 California Fire Code (CFC), 2019 California Building Code(CBC) and 2016 NFPA 72.2. RCFD fire alarm inspections are required for this project. Please schedule all field inspections at least 48 hours inadvance. Inspections canceled after 1 p.m. on the day before the scheduled date will be subject to a re-inspectionfee. Call RCFD Inspection scheduling at (951-955-5292).3. The system shall be pre-tested prior to RCFD Inspection to determine that the system is properly installed andfunctions in accordance with the approved plans and the manufacturer's installation and maintenane manual. (NFPA 72, 7.5.2)4. This system was designed and installed under the 2019 code requirements.5. A 24-hour emergency rseponse phone number shall be permanently posted adjacent to the control panel.6. Installing contractor shall provide an RCFD Record of completion to the inspector and business owner followingcompletion of alarm testing as witnessed by RCFD (CFC 907.7.2).7. Automatic fire sprinkler water flow alarms, supervisory initiating devices, and their circuits, shall be designed andinstalled so that they cannot be readily tampered with, opened, or removed without initiating a signal.8. 12. Through penetration fire stopping for all the fire rated walls, floor/ceilings and assemblies shall have an "F" or"T"rating per the CBC and standards. Installation of fire stopping detail(s) with approved methods.9. The circuit disconnect breaker providing power to the fire alarm control unit shall only be accessible to authorizedpersonnel, and shall be identified as “FIRE ALARM CIRCUIT”.10. All fire control units shall be interconnected with all other fire alarm control units located within the facility. (NFPA72: 23.8.2.1, 23.8.2.2 and 23.8.2.3).11. All audible alarm notification signals shall be a three pulse temporal pattern. (CFC 907.5.2.1.3)12. Audible alarm sound level shall meet the minimumum specified by CFC 903.4.13. When more than two visual notification devices are located within the same room or area, they shall besynchronized. (NFPA 72, 18.5.5.4..2)14. All fire sprinkler systems shall be monitored except those noted in CFC 903.4.15.The Central Supervising Station Facility (CSSF) is:ADT COMMERCIAL The CSMF's address is: 4221 W JOHN CARPENTER FWY, IRVING, TX 75063 The CSMF's phone number is: 800-341-0107 Per the CBC, the occupancy classification is ___M/S-1 The square footage of the building is __19,212___ and the square footage of the affected area is ___100 The building and/or room maximum occupant load is _192.Note: All existing fire alarm and monitoring systems undergoing qa change in monitoring companies are required tobe inspected by thr RCFD. This is to help reduce the number of nuisance alarms and and incorrect signaltransmissions. A Service Request Form must be filled out and an associated fee paid at the RCFD for thisinspection. No plan review is required for this scope of work. (CFC 907.6.5 as amended).APPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST11/10/2021 12:36:29 PMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FA2021-0009Kohl HetrickReason: I am approving this documentContact Info: 760-409-5109 FIRST FLOOR1Scale: 1/16' = 1'0"NSEWNWNESESW1/16"=1'-0"015'1530VWDOORVWVWASSOCIATELOUNGEFRZITEM_NAME ESTORE #1230Area / MerchArea / Merch17465 SF1747 SF0 SF951 SF0 SF321 SF120 SF1161 SF777 SF14134 SF19212 SF1368 LF4 LF40 LF1412 LF0 PP0 PP0 PP0 PP FACFACP1-877-776-1911Web: adt.com/commercial123--___-___-___---PREPARED BY:PROJECT NO:DATE:CHECKED BY:REVISIONSDATENO.REVISIONPROJECT MANAGER:®BY:BY:BY:BY:PROJECT LOCATIONFIRE ALARM SYSTEM-___-0-FT1-FT5-FT10-FT20-FT40-FT1/16" = 1'SCALE:CUSTOMERPETSMART19601 N 27TH AVENUEPHOENIX ARIZONA7/14/2021BUILDING INFORMATIONThis fire alarm shop drawing was preparedfor equipment application only. Theinformation contained herein is intendedto aid in the installation of this system. Nodesign changes have been made to theengineer of record's contract documents.Signed:Dated:NICET #: 142630 FIRE ALARM SYSTEMSNICET LEVEL III Andrew W EvansAndrew W. Evans7/14/2021MMCONTRACTORC-1065604LExp. 05/31/2022SATFACETODLC-10OCICSNEEIRIOFNA EDTA AICRLLLCCONSTRUCTION TYPE:OCCUPANCY TYPE:STORIES:IN SCOPE:TOTAL SQ FT IN SCOPE:EXISTING FIRE ALARM SYSTEM:BUILDING FULLY SPRINKLERED:IIIBM/S-11119,212YESYESCODES ADOPTED BY CALIFORNIA AHJCalifornia Building Code 2019(Vol 1 & 2)California Existing Building Code 2019California Fire Code 2019California Mechanical Code 2019ADT COMMERCIAL #6689825809 BUSINESS CENTER DRSUITE FREDLANDS CA 92374SA#891115934DR#34837JOB#280681893PETSMART #123079 375 Hwy 111La Quinta CA 92253SHEET:TITLE:This document, materials or presentation, whether offered online or presented in hard copy (“ADT Informational Tools”) is for informational purposes only. ADT PROVIDES THESE ADT INFORMATIONAL TOOLS “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The ADT Informational Tools contain ADT proprietary and confidential materials. No part of the ADT Informational Tools may be modified, altered, reproduced, stored in or introduced into a retrieval system, or transmitted in anyform or by any means (electronic, mechanical, photocopying, recording, or otherwise), without the prior written permission of ADT, except as otherwise permitted by law. Prior to publication, reasonable effort was made to validate this information. The ADT Information Tools may include technical inaccuracies or typographical errors. Actual savings or results achieved may be different from those outlined in the ADT Informational Tools. The recipient shall not alter or remove any part of this statement.CELLULAR ADDITION12 vdc 7AHBATTERY-+MODULERELEASEUSB R Y G BSDI2Device BusINPUTS16.5 VACBATTERY2.2 k End ofLine Resistors1 COM 23 COM 4PANELLINE 1+16.5VACPANELLINE 2-BATTERYNC C NORELAY 1 C NORELAY 2RELAY 312VAUX COM 1 COM 2 3 COM 4TXPWRMODULE 1TMPREXTERNALANNUNCTRBLRXBAT C NOB465B444RESERVED FOR AHJFA1PH2PH1-+BATTERYBATTERY-+FIRE ALARMEXISTING DEDICATED AC POWER4S BACK BOX W/ MUD RING 4S BACK BOX W/ MUD RING ABOVE FINISH CLG.3/4" FLEX STUBBEDANNUNCIATOR/KEYPADTO BE MOUNTED BETWEEN 54"-60"NOTIFICATION APPLIANCE4 S BACK BOXFINISH FLOORNOT TO SCALEHEIGHT REQUIREMENTSOPERATING HANDLE TO BE48 INCHES CEC SEC. 760-16-NFPA 72 2019 SECTION 17.15.6MANUAL PULL STATION4S BACK BOX W/ MUD RING SPOT DETECTOR MOUNTING DETAILRCEILING HEIGHTS AT HEIGHTS OF NOT LESS-NFPA 72 2019 ED. SECTION 18.4.9.1THAN 6".TOPS NOT LESS THAN 90" A.F.F. AND BELOWIF CEILING HEIGHTS ALLOW, WALL MOUNTEDAUDIBLE APPLIANCES SHALL HAVE THEIR -NFPA 72 2019 SECTION 18.5.5.1THAN 96" A.F.F.ELESS THAN 80" AND NOT GREATERWALL MOUNTED VISUAL DEVICES SHALL BE SUCH THAT THE ENTIRE LENS IS NOTIFDEVICE TO PROTRUDE NO MORE THAN 4" IF IN CORRIDORS AND WALKWAYS.-NFPA 72 2019 FIG A.17.7.3.2.1DEVICE MOUNTINGTHE CLOSEST EDGE OF THE DETECTORMEASUREMENTS SHOWN ARE TOACCEPTABLE HERETOP OF DETECTORNOTE:SIDEWALLMAX.12 in.NEVER HEREACCEPTABLE HERE4 in.FINISH CEILINGDIAGRAM4 in.OUTLET BOXESWIRE FILL CHARTNOTE: NEC TABLE 1 APPLIES ONLY TO TABLE COMPLETE CONDUIT OR TUB-ING SYSTEMS AND IS NOT INTENDED TO APPLY TO SECTIONS OF CONDUITOR TUBING USED TO PROTECT WIRING FROM PHYSICAL DAMAGE.THIS SYSTEM USES FPL CABLE AND IS BEING INSTALLED PER NEC ARTICLE760-28. THE ABOVE DIAGRAMS AND CHARTS APPLY ONLY TO PORTIONS OFTHE FIRE SYSTEM THAT USES 14ga THHN OR OTHER APPROVED/LISTEDNEC TABLE 4, CHAPTER 9 DIMENSIONS AND PERCENT AREA OF CONDUITAND OF TUBING AREAS OF CONDUIT OR TUBING FOR THE COMBINATIONNEC TABLE 3B MAX # OF CONDUCTORS IN TRADE SIZES OF CONDUIT OR1-1/244367094THHN326181110WIRE THAT WOULD REQUIRE THIS TYPE OF INSTALLATION.OF WIRES PERMITTED IN TABLE 1, CHAPTER 9.2 1/22.4694.793.06837.381.6102.067.8241.3801.049.622TRADESIZE1 1/21 1/43/41/2128AREA2.043.36.531.50.86.3093516LETTERSCONDUIT TRADE SIZETUBING BASED ON TABLE 1, CHAPTER 9.4 x 4 x 1-1/2(PER 2016 N.E.C. 314-16A)MULTIPLE GANGSINGLE GANGCONDUCTORTYPESIZE121412939101318243/41/251691-1/4BOX SIZE vs. NUMBER OF WIRES3-1/4 x 1-1/23-1/2 x 1-1/24 x 4 x 1-1/44 x 1-1/24 x 2-1/8OCTAGONOCTAGONOCTAGONOCTAGON16473160106513679136863-1/22-1/2164114154239645No.12119363No.1431012734814124No.16710TOTAL(SQ. IN.)(IN.)DIA.INTERNAL129No.1851417105161410No.10564 x 4 x 2-1/816282421181119161413FIRE STOP PENETRATION DETAILS"L" RATING AT 400 FT "F" - LESS THAN 1 CFM /SQ. FT (SEE ITEM 3)"F" RATINGS - 1, 2, 3, AND 4 HR (SEE ITEMS 2 & 3)"T" RATINGS - 0, 1, 2, 3, AND 4 HR (SEE ITEM 3)"L" RATINGS AT AMBIENT - LESS THAN 1 CFM/ SQ. FT (SEE ITEM 3)SYSTEM NO. UL 1001 (FORMERLY SYSTEM NO. 147)PENETRATION THROUGH CONCRETE WALLS4 HOUR RATING UL SYSTEM CAJ1044PENETRATION THROUGH GYPSUM WALL BOARD1 HOUR RATING UL SYSTEM NO. CAJ1006CONC. WALLMETAL PIPECONCRETE WALLCP-25WB CAULK6 INCH DIAMETER3M FIRE BARRIERWHEREVER APPLICABLEUL SYSTEM NO. CAJ10271 HOUR FIRE RATEDGYPSUM BOARD6 INCH DIAMETERGYP. BOARD FRAMED WALLUL SYSTEM NO. WL1001WHEREVER APPLICABLEMETAL PIPE12INCH DIAMETERMAXIMUM PIPEOR CONDUIT4611ANNULAR0 TO 3/16INCHESSPACE IN0 TO 1/41/4 TO 1/23/16 TO 3/81/4 TO 1/21/3 INCH MAXIMUMANNULAR SPACING1 IN MINERAL WOOLPACKING1/4 INCH BEAD 3MFIRE BARRIER CP 253M FIRE BARRIERCS-195+ WRAP/STRIPCAULK"T"HOURRATING 0 + 1OR 23 OR 4HOURRATING1 OR 21 OR 23 OR 41 OR 23 OR 4"F"0001. WALL ASSEMBLYTHE 1, 2, 3 OR 4 HOUR FIRE RATED GYPSUM WALL BOARDS/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES.A. STUDS- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAXIMUM 2 HOUR FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST ON NOM 2x4in. LUMBER SPACED IN 16in. OC (On Center) WIT (Weight) NOM (Nominal) 2x4in. LUMBER, PLATES AND CROSS BRACES. STEEL STUDS TO BE 3-38in. WIDE BY 1-3/8 IN.DEEP CHANNELS SPACED A MAXIMUM 24in. OC.B. WALLBOARD GYPSUM- NOM 12 OR 38 in. THICK, 4ft. WIDE WITH SQUARE OR TAPERED EDGE. THE GYPSUM WALL BOARD RYPS, THICKNESS, NUMBER OF LAYERS, FASTENER TYP AND SHEET ORIENTATION SHALL BE SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX. DIAMETER OF AN OPENING IS 13-1/2 IN.2. PIPE OR CONDUIT- NOM 12in. DIAMETER (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE NOM 6in. DIAMETER (OR SMALLER) STEEL CONDUIT, NOM 4in. DIAMETER (OR SMALLER) STEEL (OR SMALLER) FLEXIBLE STEEL CONDUIT. WHEN COPPER PIPE OR FLEXIBLE STEEL CONDUIT IS USED, MAX. "F" RATING OR FIRE STOP SYSTEM (ITEM STRUTTED USING STEEL CHANNEL STUDS). A MAX. OF ONE PIPE OD CONDUIT IS PERMITTED IN THE FIRST STOP SYSTEM, PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY AND WIDTH TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY.3. FILL, VOID OR CAVITY MATERIAL- CAULK FILL MATERIAL INSTALLED TO COMPLETELY FILL ANNULAR SPACE BETWEEN PIPE OR CONDUIT AND GYPSUM WALLBOARD AND WITH A MINIMUM 1/4 IN. DIAMETER BEAD OF CAULK APPLIED TO PERIMETER OF PIPE OR CONDUIT AT IT'S EGRESS FROM THE WALL CAULK INSTALLED SYMMETRICALLY ON BOTH SIDES OF THE WALL ASSEMBLY. RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE. THE HOURLY RATING OF THE "T" RATING OF THE FIRE STOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED BELOW:- WHEN COPPER PIPE IS USED, "T" RATING IS 0 NOM MINNESOTA MINING & MFG. CO. TYPES CP-25N/S, CP-25WB, CP-25WB+(NOTE: "L" RATINGS APPLY WHEN TYPE CP-25WS+CAULK IS USED).//Scope is for themodification of the firealarm communicationonly. Existing fire alarmsystem to remain withoutmodification. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7300-1615:0502 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Peter Namisnak (585) 678-3655 Fax (585) 678-3263 Email: peter.namisnak@us.bosch.com DESIGN: Model B444 Cellular Wireless Communicator Module, transmits in 4G LTE wireless communication. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:Model B444 12 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as Cellular Wireless Communicator Module transmission device for use with separately listed and compatible fire alarm control units. Acceptable for use as single communication path or multiple communications paths. Refer to listee’s Installation Instruction Manual for details. July 01, 2021Date Issued:Listing Expires June 30, 2022 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7300-1615:0253 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Peter Namisnak (585) 678-3655 Fax (585) 678-3263 Email: peter.namisnak@us.bosch.com DESIGN: Model B465 Connettix Universal Dual Path Communicator and Model B46 Communicator Status Indicator. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:Model B465 16.5 Vac Model B46 12 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as digital ethernet or cellular alarm transmission devices for use with compatible fire alarm control units. Refer to listee’s Installation Instruction Manual for details. 09-02-15 gt July 01, 2021Date Issued:Listing Expires June 30, 2022 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. UL LLC CERTIFICATE OF COMPLIANCE COVER PAGE Applicant Subscriber No: 370746-011 Service Center Number: 22 Listed Service From: IRVING, TX ADT COMMERCIAL 4221 W JOHN CARPENTER FWY IRVING TX 75063-2924 ADT COMMERCIAL 4221 W JOHN CARPENTER FWY IRVING TX 75063-2924 08-JAN-2021 Alarm Service Company:Service Center: UUFX S2684 20 CRZM BP10566 1 CPVX BP1790 3 CRZH BP6719 7 ACTIVE LISTINGS CCN File No. Vol. No. Contract Number is: LLC20116576 THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. CERTIFICATE OF COMPLIANCE ADT COMMERCIAL 4221 W JOHN CARPENTER FWY IRVING TX 75063-2924 ADT COMMERCIAL 4221 W JOHN CARPENTER FWY IRVING TX 75063-2924 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category BP1790 - 3 BP6719 - 7 BP10566 - 1 S2684 - 20 ***THIS CERTIFICATE EXPIRES ON 31-MAR-2022 *** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" CPVX CRZH CRZM UUFX [Burglar Alarm Systems] Central Station [Burglar Alarm Systems] National Industrial Security Systems Monitoring Stations, National Industrial Security [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station IRVING, TX Alarm Service Company: (370746-011)Service Center: (370746-011) Listed Service From: Applicant ID No: Service Center No: Expires: 370746-011 22 31-MAR-2022 Intrusion Alarm Systems | B465 Universal Dual Path Communicator B465 Universal Dual Path Communicator www.boschsecurity.com u Compatible with any control panel using Contact ID, SIA, Pulse 3/1 or Pulse 4/2 communication formats (auto detecting) u No control panel reprogramming required to install u Supports Ethernet directly and optional plug-in cellular communication technologies in single, or multi-path configurations u Supports four configurable inputs and three configurable outputs u Approved for Commercial Fire/Burglary applications as sole, primary, or secondary communication path The B465 Conettix Universal Dual Path Communicator converts the Public Switch Telephone Network (PSTN) digital dialer, or dry contact outputs from an intrusion/ fire control panel to an IP signal for transmission over the Ethernet or cellular network. The B465 Conettix Universal Dual Path Communicator is UL 864 10th Edition approved per NFPA 72 version 2013. The module can use its built-in Ethernet connection, and/or an optional Conettix plug-in cellular module (B440/B441/B442/B443) to send reports to the central station receiver. Automation programming for the supported control panel remains unchanged with the installation of the B465 module, thus simplifying the installation process This allows for a smooth transition from the PSTN realm into IP. All messages generated internally by the B465 are shown in Contact ID format at the central station. The module can be powered from a 16.5 VAC transformer or 24 VDC power supply. System overview The B465 simulates dial tone and line voltages when the digital dialer has a report to send. The module simulates a PSTN connection to the central station. The module decodes the control panel’s PSTN dialer report and sends the decoded reports by IP connection using Bosch’s Conettix Protocol to the Conettix D6600, D6100IPv6, or D6100i Communication Gateway/Receiver (referred to as the receiver). When the receiver acknowledges receipt of the message, it sends an acknowledgement report to the module which in turn sends an acknowledgement to the connected control panel. This process maintains true end-to-end security. 1 10 11 2 8 65 7 9 4 TMPRBATETHERNET EXTERNALANNUNCX MODULE 1 Y MODULERELEASE 1 COM 2 PNL LINE 23 COM 4 PNL LINE 1C NORELAY 2+ BAT -18VAC NO C NCRELAY 1 TRBL TX RX AC PANELLINE 2 USB ETHERNET 100BASE-T LINK COMMUNICATION MODULE 1 3 COM 41 COM 2 R Y G B SDI2Device Bus 18 VAC BATTERY PANELLINE 1 BATTERY AC RXTX SYSTEM TROUBLE INPUTS2.2 k End ofLine Resistors C NORELAY 3 12VAUX COM 3 Callout ー Description 1 ー Intrusion/fire control panel 2 ー Control panel phone line connections 3 ー B465 Conettix Universal Dual Path Communicator 4 ー B44x plug-in cellular communicator 5 ー Ethernet connection (LAN/WAN) 6 ー Internet 7 ー Cellular communication to cellular carrier 8 ー Cellular carrier network 9 ー Conettix receiver/gateway 10 ー Conettix receiver/gateway 11 ー Monitoring center automation Functions PSTN inputs (2) When the control panel’s PSTN dialer sends a message, the module simulates a PSTN connection to the central station. The module connects to the host control panel through either one or both of the Phone Line inputs. Both Panel Line 1 and Panel Line 2 of the module run 28 VDC and support Contact ID (4 and 10 digit account codes), Pulse 3/1, Pulse 4/2, and SIA communication formats. The B465 is setup to auto detect the communication format which eliminates programming steps. IP Communication options The module uses the on-board Ethernet connector, and/or optional B440 Conettix Plug-in Communicator, Cellular (3G), B441 Conettix Plug-in CDMA Cellular Communicator, B442 Conettix Plug-in GPRS Cellular Communicator, or B443 Conettix Plug-in HSPA+ Cellular Communicator to communicate with a Conettix D6600, Conettix D6100i or a Conettix D6100IPv6 Communications Receiver/Gateway. Using Conettix IP communication protocol offers a secure path that includes anti-replay/anti-substitution features and provides enhanced security with up to AES 256-bit encryption. The module supports Domain Name System (DNS) for central station communication. DNS provides ease of use, eliminating the need to use static IP addresses as your reporting destination, and accommodates a simple solution for central station disaster recovery. Direct wire inputs The B465 provides four on-board inputs. Each input functions independently and does not interfere with the operation of the others. The module monitors the input loops for normal, shorted, or open conditions between an input terminal and any of the input common terminals. Inputs are disabled by default so no EOL resistors are required until activated. These four inputs on the B465 connect to dry contact outputs on the control panel and generate Contact ID reports instead of using a phone line connection/or in addition to using the control panel phone connection. The available functions are: • Panel System Trouble • Panel AC Fail • Panel Battery Trouble • Fire Alarm • Fire Trouble • Burg Alarm • Burg Trouble • Fire Supervisory Each input allows the use of dry contacts or powered outputs up to 30 VDC if needed. The inputs use 2.2K EOLs to monitor the dry contact outputs when connected to dry contacts. The inputs recognize the following thresholds when using dry contacts: 2.0 to 3.0 VDC = Normal, 3.7 to 5.0 VDC = Open, 0.0 to 1.3 VDC = Short. Outputs Includes three programmable output relays rated at 30 VDC, 0.1 A. These outputs can be used to show the status of the B465 or they can be connected to the control panel zone inputs for reporting B465 system faults. The three outputs consist of RELAY 1, RELAY 2, and RELAY 3. • RELAY 1 is active (energized) once the B465 is running. If the B465 detect a problem or loses power, RELAY 1 de-energizes, which can be used to indicate a system trouble on the local control panel's zone inputs, if required. Depending on the configuration required to create a system trouble on the control panel, the installer needs to use either the NO and COM or the NC and COM connections. Refer to the control panel manual for the required zone configuration to obtain the proper input response. • RELAY 2 is a normally open (NO) relay with contacts that close when the desired function programmed is detected. • RELAY 3 is a normally open (NO) relay with contacts that close when the desired function programmed is detected. 2 | B465 Universal Dual Path Communicator Input power supply The B465 uses a 16.5 VAC transformer or 24 VDC voltage for its primary power source. The approved transformers are the D1640 plug-in transformer, D1640-CA plug-in transformer, or D1640-120WI transformer. The B465 can optionally be powered from 24 VDC power source applied to the AC terminals. B465 modular connections The B465 module has three modular connections. •Cellular plug-in connector. Connects to a cellular communication module. •Tamper connector. Connects the ICP-EZTS Dual Tamper Switch for monitoring the enclosure cover. •External Annunciator connector. Connects to the optional B46 module. On-board LED Indicators The B465 has a total of ten on-board LEDs that indicate the module's status (SYSTEM TROUBLE, TX, RX, POWER, BATTERY, HEARTBEAT, Panel Line 1 (ACT),Panel Line 2 ( ACT), 100BASE-T and ETHERNET LINK). B46 External Annunciator (Optional) The B46 is an optional module that provides external module LED and sounder status when installed in a supported enclosure. The module has 3 LEDs (System Trouble, Power, and Battery) which illuminate through the B46 LED cover. The LED cover snaps into a knockout in the enclosure door. The B46 is compatible with the B10, B10R, B11, B11R, and D8103 enclosures. Certifications and approvals Region USA UL 365 - Police Station Connected Burglar Alarm Units and Systems UL 609 - Local Burglar Alarm Units and Systems UL 636 - Holdup Alarm Units and Systems UL 864 - Control Units and Accessories for Fire Alarm Systems (Commercial Fire) UL 985 - Household Fire Warning System Units UL 1023 - Household Burglar Alarm System Units UL 1076 - Proprietary Burglar Alarm Units and Systems UL 1610 - Central Station Burglar Alarm Units NIST FIPS 197 AES Certification (IP Communications) CSFM approved FCC Part 15 Class B Canada CAN/ULC S303 - Local Burglar Alarm Units and Systems CAN/ULC S304 - Signal Receiving Centre and Premise CAN/ULC S545 - Residential Fire Warning System Control ICES-003 - Information Technology Equipment (ITE) ULC-ORD C1023 - Household Burglar Alarm System Units ULC-ORD C1076 - Proprietary Burglar Alarm Units and System Region Certification USA UL 20150807-S1871 CSFM 7300-1615:0253 FDNY-CoA 6214 Parts included Quantity Component 1 B465 Conettix Universal Dual Path Communicator 1 Hardware pack 1 Quick Start Guide (hardcopy) 1 Wiring label (hardcopy) 1 Literature (mini-CD) Technical specifications Properties Dimensions 4.40 in x 6.90 in x 1.50 in (111 mm x 175 mm x 38 mm) Environmental considerations Relative humidity 5% to 93% at +32°C (+90°F) Temperature (operating)0°C to +49°C (+32°F to +120°F) Operational use Indoor use only Power requirements Standby battery current Battery input: B465: Idle 150 mA; Alarm 230 mA 24 VDC input current 24 VDC input: B465: Idle 120 mA; Alarm 160 mA Wiring Terminal wire size 12 AWG to 22 AWG (2.0 mm to 0.65 mm) Transformer secondary wiring length 15 m (50 ft) maximum unshielded wire Control panel phone line wiring 100 Ω loop resistance, maximum unshielded wire 3 | B465 Universal Dual Path Communicator Input loop wiring 100 Ω loop resistance, maximum unshielded wire Ethernet wiring 100 m (328 ft) maximum using Cat 5 wire or better Compatibility Compatible PSTN input formats Ademco Contact ID (SIA DC-05) +10 digit account codes Pulse 3/1, 3/1 Checksum (2300 Hz ACK Tone) Pulse 3/1, 3/1 Checksum (1400 Hz ACK Tone) Pulse 4/2 (2300 Hz ACK Tone) Pulse 4/2 (1400 Hz ACK Tone) SIA (SIA8, SIA20) – 110 and 300 baud Receivers D6600 D6100i D6100IPv6 Cellular B440 Conettix Plug-in Communicator, Cellular (3G) B441 Conettix Plug-in CDMA Cellular Communicator B442 Conettix Plug-in GPRS Cellular Communicator B443 Conettix Plug-in HSPA+ Cellular Communicator Modules B46 External Annunciator Enclosures B10 Medium Control Panel Enclosure B10R Medium Control Panel Enclosure (Red) B11 Small Control Panel Enclosure B11R Small Control Panel Enclosure (Red) D8103 Universal Enclosure D8108A Attack Resistant Enclosure Transformers D1640 transformer 120 VAC input, 16.5 VAC, 40 VA output plug-in D1640-CA transformer 120 VAC input, 16.5 VAC, 40 VA output plug-in D1640-120WI transformer 120 VAC input, 16.5 VAC, 40 VA output wired in Ordering information B465 Universal Dual Path Communicator Compatible with control panels using a standard digital dialer format. Provides end-to-end security. Allows digital dialer control panels to work over an IP network (such as LAN, WAN, or the Internet). Order number B465 Accessories B46 External Annunciator An optional module that uses audio and LEDs to show System Trouble, Power, and Battery status through a knockout on select enclosure doors Order number B46 B10 Medium Control Panel Enclosure White, steel enclosure. Accepts an optional lock and tamper switch. Measures 35.6 cm x 31.8 cm x 7.6 cm (14 in x 12.5 in x 3 in). Order number B10 B10R Medium Control Panel Enclosure (Red) Red, steel enclosure. Accepts an optional lock and tamper switch. Order number B10R B11 Small Control Panel Enclosure White, steel enclosure. Accepts an optional lock and tamper switch. Measures 27.8 cm x 25.9 cm x 8.32 cm (10.9 in x 10.2 in x 3.3 in). Order number B11 B11R Small Control Panel Enclosure (Red) Red, steel enclosure. Accepts an optional lock and tamper switch. Measures 27.8 cm x 25.9 cm x 8.32 cm (10.9 in x 10.2 in x 3.3 in). Order number B11R D8103 Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). Order number D8103 D8108A Attack Resistant Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). UL Listed. Includes lock and key set. B520, B4512, and B5512 require the B12 mounting plate. Order number D8108A B12 Mounting Plate for D8103 Enclosure Required for mounting select control panels and other devices in D8103, D8108A, D8109, or BATB Battery Box enclosures. Order number B12 D101 Lock and Key Set Short-body lock set with one key supplied. Uses the D102 (#1358) replacement key. Order number D101 ICP‑EZTS Dual Tamper Switch Combination tamper switch with a wire loop for additional tamper outputs. Order number ICP-EZTS D1640 Transformer System transformer rated at 16.5 VAC, 40 VA. Order number D1640 D1640-CA Transformer For use in Canada. System transformer rated at 16.5 VAC, 40 VA. Order number D1640-CA 4 | B465 Universal Dual Path Communicator B440 Conettix Plug-in Cellular Communicator Dual technology 3G EVDO/CDMA cellular communicator for secure two-way IP communication on the Verizon Wireless network. Order number B440 B441 Conettix Plug-in Cellular Communicator Multi-function CDMA cellular communicator for secure two-way IP communication on the Verizon Wireless network. Order number B441 B442 Conettix Plug-in GPRS Cellular Communicator Multi-function cellular communicator that provides IP communication over a (GPRS) cellular network. Order number B442 B443 Conettix Plug-in HSPA+ Cellular Communicator Multi-function 3G/4G cellular communicator providing IP communication over a GPRS/EDGE/UMTS/HSPA+ cellular network. Order number B443 5 | B465 Universal Dual Path Communicator Represented by: Europe, Middle East, Africa:Germany:North America:Asia-Pacific: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia © Bosch Security Systems 2016 | Data subject to change without notice 18116851979 | en, V13, 01. Aug 2016 Intrusion Alarm Systems | B444 Conettix Plug-in 4G LTE Cellular Communicator B444 Conettix Plug-in 4G LTE Cellular Communicator www.boschsecurity.com u Secure Conettix IP communication from compatible Bosch panels to Bosch receivers using Verizon 4G LTE cellular network u Remote programming and monitoring of compatible Bosch panels u Personal SMS message and e-mail notification options u Direct configuration from Bosch Remote Programming Software (RPS) eliminating the need for separate configuration u Simple LED status information and advanced keypad diagnostics available with easy 2 step plug-in installation, troubleshooting, and maintenance The cellular communicator enables secure two-way IP communication over the Verizon 4G LTE cellular network by plugging into a compatible control panel or communicator interface. Typical applications are: • Alarm reporting to a central station • Remote control panel programming through Remote Programming Software with supported control panels • Remote monitoring and control through a mobile application with supported control panels • Personal notification using SMS for compatible control panels Notice Cellular capability requires an Installer Services account and appropriate data plan. System overview Callout ᅳ Description Callout ᅳ Description 1 ᅳ Cellular communicator 7 ᅳ Remote PC’s network connection 2 ᅳ Compatible control panel 8 ᅳ Remote PC running RPS 3 ᅳ Antenna cable 9 ᅳ Personal SMS notification 4 ᅳ Magnetic base antenna 10 ᅳ Ethernet connection 5 ᅳ Base station on wireless carrier’s network 11 ᅳ Central monitoring station 6 ᅳ IP network cloud Functions Activation The B444 module is shipped pre-activated. The B444-C module needs to be activated. Activate the module by emailing: installer.services@us.bosch.com, or by call Bosch Installer Services at: 800-289-0096, option 6. Conettix IP communication via Cellular In addition to the security provided by the network operator, the cellular communicator uses our Conettix IP protocol that supports: • Flexible polling intervals • Resistance to Denial of Service attacks • 128-bit to 256-bit AES encryption with Cypher Block Chaining • Anti-replay/anti-substitution keys Easy Installation, troubleshooting, and maintenance • No networking expertise required at field site (no firewall or router settings) • No PC or special tools required for installation and troubleshooting • Service plans and settings managed through RPS • Diagnostic LEDs for on-site troubleshooting LED Function Blue (heartbeat)System status indicator Red Unacceptable signal strength Yellow Marginal signal strength 1 Green Good signal strength 2 Green Very good signal strength Remote programming of Bosch control panels The cellular communicator supports secure RPS programming of compatible Bosch control panels. Personal notification and control The cellular communicator supports the Bosch Remote Security Control mobile application and can be configured for SMS personal notification reports to mobile phones or e-mail addresses. Remote Connect Service Support Remote Connect Service enables a secure control panel connection to remote programming software (RPS) using Bosch Cloud services. The service allows a secure TLS connection to a control panel without specific port and router settings and without a static IP or DNS. Certifications and approvals Region Certification USA Verizon Open Development Certified Region Regulatory compliance/quality marks USA UL UL 864 - Standard for Control Units andAccessories for Fire Alarm Systems UL UL 1076 - Proprietary Burglar AlarmUnits and Systems UL UL 1610 - Central Station Burglar AlarmUnits UL UL 365 - Police Station Connected Bur-glar Alarm Units UL UL 609 - Standard for Local BurglarAlarm Units and Systems UL UL 636 - Holdup Alarm Units and Sys-tems UL UL 985 - Household Fire Warning Sys-tem Units UL UL 1023 - Household Burglar Alarm Sys-tem Units FCC Part 15 Class B Installation/configuration notes Mounting considerations The module plugs into any compatible control panel, available in a variety of enclosures. Wiring considerations The module connects to any compatible control panel without tools or physical wiring for power. When used with the B450, the B450 is wired to the control panel data bus. The cellular module has a screw on SMA antenna connection. Compatibilities Devices B9512G/B9512G-E, B8512G/B8512G-E B6512 B6512/B5512/B4512/B3512, B5512E/ B4512E/B3512E control panel with firmware v3.05 or higher (direct insertion) The module is compatible with most Bosch control panels when used with a B450 Conettix Plug-in Communicator Interface with firmware v3.05 or higher. Refer to the B450 datasheet for complete control panel compatibility listings. B465 Conettix Universal Dual Path Communicator with firmware v2.0 or higher. B40 antennas Cellular 4G LTE - Cat 1 Commercial Fire and Burglary applications Approved for Commercial Fire/Burglary applications as sole, primary, or secondary communications path when the system is installed to the NFPA-72 specification 2 | B444 Conettix Plug-in 4G LTE Cellular Communicator Technical specifications Electrical Current (operating) Standby: 35 mA Alarm: 100 mA Voltage (operating)12 VDC nominal Radio Verizon LTE CAT 1 Band 4 and 13 Environmental Environment Environmental Class III - Indoor Relative humidity 5 - 93% at +32°C (+90°F) non-condensing Operating temperature 0°C to +49°C (+32°F to +120°F) Mechanical Board dimensions 2 in x 3.68 in x 0.60 in (50 mm x 93.5 mm x 15.25 mm) Antenna (included)• Magnetic base omni-directional • 8.2 ft (2.5 m) cable with SMA connector Ordering information B444 Plug-in cellular module, VZW LTE, hot Pre-activated 4G LTE cellular communicator for secure two-way IP communication on the Verizon Wireless LTE network. Order number B444 B444-C Plug-in cell module, VZW LTE, cold Non-activated 4G LTE cellular communicator for secure two-way IP communication on the Verizon Wireless LTE network. Order number B444-C 3 | B444 Conettix Plug-in 4G LTE Cellular Communicator Represented by: Europe, Middle East, Africa:Germany:North America:Asia-Pacific: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia © Bosch Security Systems 2018 | Data subject to change without notice 35406955147 | en, V5, 14. Aug 2018 Intrusion Alarm Systems | B11R Enclosure, small, red B11R Enclosure, small, red www.boschsecurity.com u Easy to install standoff locations for mounting supporting modules u Made with cold-rolled steel with a red matte finish for fire applications u Easy access mounting locations for optional transformers The B11R Small Control Panel Enclosure is a red enclosure made of cold-rolled steel that is 0.7 mm (23 gauge) thick. It houses many different Bosch control panels and modules. The enclosure holds one battery (up to 7 Ah). It is compatible with the following accessories: •D101 Lock and Key Set. Standard lock set with one key supplied. Uses the D102 (#1358) replacement key. •D110 Tamper Switch. Screw-on tamper switch that fits all enclosures. Shipped in packages of two. •ICP-EZTS Dual Tamper Switch. Combination tamper switch with a wire loop for additional tamper outputs. Certifications and approvals Region Regulatory compliance/quality marks USA UL S1871-19850314-CertificateofCompli-ance Canada ULC [D8108A, D8108AH, D8109, D8109G,D8109H, D8109L,B8103, D8103,B12, B10, B10R, B11, B11R Installation/configuration notes Compatibility Devices B465 Conettix Universal Dual Path Communicator D101 Lock and Key Set ICP-EZTS Tamper Switch Set D110 Tamper Switch Parts included Quantity Component 1 Enclosure 1 Hardware pack 1 Installation Manual Technical specifications Properties Dimensions 10.9 in x 10.2 in x 3.3 in (27.8 cm x 25.9 Cm x 8.3 cm) Material 1.0 mm (20 gauge) cold-rolled steel Color Red Environmental considerations Mounting considerations Mount in dry indoor locations. Ordering information B11R Enclosure, small, red Red, steel enclosure. Accepts an optional lock and tamper switch. Order number B11R Accessories D101 Enclosure lock and key set Short-body lock set with one key supplied. Uses the D102 (#1358) replacement key. Order number D101 ICP-EZTS Dual tamper switch Combination tamper switch with a wire loop for additional tamper outputs. Order number ICP-EZTS D110 Tamper switch for enclosure, 2pcs Screw‑on tamper switch that fits all enclosures. Shipped in packages of two. Order number D110 2 | B11R Enclosure, small, red Represented by: Europe, Middle East, Africa:Germany:North America:Asia-Pacific: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia © Bosch Security Systems 2020 | Data subject to change without notice 18864759435 | en, V9, 26. Jun 2020 Intrusion Alarm Systems | D101 Enclosure lock and key set D101 Enclosure lock and key set www.boschsecurity.com u Lock and key set fits Bosch enclosures The D101 Lock and Key set is a short-body lock set with one key supplied. The set is compatible with several enclosures. Installation/configuration notes Compatible with the D102 (#1358) replacement key. Parts included Quantity Component 1 Lock 1 Key Technical specifications Weight 0.017 lb. (0.008 kg) Color Silver Ordering information D101 Enclosure lock and key set Short-body lock set with one key supplied. Uses the D102 (#1358) replacement key. Order number D101 Intrusion Alarm Systems | D1640 Transformer plug-in, 16V 40VA D1640 Transformer plug-in, 16V 40VA www.boschsecurity.com u System transformer rated at 16.5 VAC, 40 VA u Suitable for use on approved UL applications in the USA Certifications and approvals Region Regulatory compliance/quality marks USA UL UOXX: Control Unit Accessories, System(UL864, 9th edition) CSFM California State Fire Marshal (see ourwebsite) Parts included Quantity Component 1 Transformer Technical specifications Rating 16.5 VAC, 40 VA Dimensions 3.2 in x 2.8 in x 2.2 in (81 mm x 70 mm x 56 mm) Color White Ordering information D1640 Transformer plug-in, 16V 40VA System transformer rated at 16.5 VAC, 40 VA. Order number D1640 Fire Alarm Systems | D8004 Transformer enclosure kit, grey D8004 Transformer enclosure kit, grey www.boschsecurity.com u Separates high and low voltage within the enclosure u Comes with a duplex grounded receptacle u Easy wiring and mounting The D8004 Transformer enclosure protects the AC plug‑in transformer ensuring that it remains securely fixed to the AC wall outlet. The enclosure may be required for certain applications, commonly fire alarm applications. Certifications and approvals Region Regulatory compliance/quality marks USA UL ANSI/UL 365 Police Station ConnectedBurglar Alarm Units and Systems UL ANSI/UL 464 Audible Signal Appliances UL ANSI/UL 609 Local Burglar Alarm Unitsand Systems UL ANSI/UL 1023 Household Burglar AlarmSystem Units UL ANSI/UL 1610 Central Station BurglarAlarm Units UL ANSI/UL 1635 Digital Alarm Communi-cator System Units UL UL 864 - Standard for Control Units andAccessories for Fire Alarm Systems(10th edition) CSFM California State Fire Marshal Region Regulatory compliance/quality marks FDNY-CoA 6286 D7412GV4 D9412GV4 NYC COA6286 2018-2021 FDNY-CoA 6196 NYC-MEA 12-92-E, Vol. 12 NYC-MEA 12-92-E, Vol. XV Canada ULC CAN/ULC-S304 Central and MonitoringStation Burglar Alarm Units Parts included Quantity Component 1 Transformer cover 1 Outlet cover 1 Outlet box 1 High and low voltage divider plate 1 Duplex grounded receptacle Technical specifications Environmental Environment Indoor, dry Mechanical Color Gray Dimensions (LxWxH) 8.8 in. x 4.7 in. x 3.0 in. (22.4 cm x 11.9 cm x 7.6 cm) Material Cover Outlet box cold-rolled steel, 18 gauge (1.2 mm) Galvanized steel, 18 gauge (1.2 mm) Weight Gross Net 3.79 lb. (1.72 kg) 3.28 lb. (1.49 kg) Ordering information D8004 Transformer enclosure kit, grey For applications that might require a remote transformer in an enclosure. Can be used with B Series control panels and D9412GV4/D7412GV4 control panels. Order number D8004 2 | D8004 Transformer enclosure kit, grey Represented by: Europe, Middle East, Africa:Germany:North America:Asia-Pacific: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia © Bosch Security Systems 2020 | Data subject to change without notice 2739800075 | en, V26, 26. Jun 2020 Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. U.L. recognized under file number MH 20567. Sealed Lead-Acid Battery L: 5.94 in (151 mm) W: 2.56 in (65 mm) H: 3.70 in (94 mm) TH: 3.86 in (98 mm) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. 1720 Hayden Drive Carrollton, Texas 75006 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com www.upgi.com Nominal Voltage Nominal Capacity 20-hr. (0.35A) 10-hr. (0.65A) 5-hr. (1.2A) 1-hr. (4.2A) Approximate Weight Internal Resistance (approx.) Shelf Life (% of normal capacity at 77º F (25º C)) 3 Months 6 Months 12 Months Temperature Dependancy of Capacity 104º F 77º F 12 volts 7 Ah 2.1 A or smaller 14.4 - 14.9 V 77º F (25º C) (20 hour rate) 6.51 Ah 6 Ah 4.2 Ah 4.8 lbs (2.18 kgs) 25mŸ 91% 82% 64% 102% 100% 85% 32º F 5º F Charge Method 65% (Constant Voltage) Cycle Use Float Use Initial Current Control Voltage 13.5 - 13.8 VControl Voltage (Repeating Use) Specification Physical Dimensions: in (mm) Terminals All specifications are subject to change. S1204-1 UPG No. 40800 Maintenance-Free UB1270 5.94in (151mm)3.86in (98mm)3.70in (94mm)2.56in (65mm)Discharge Characteristics (Minute) (Hour) Discharge timeCell voltage (V/Cell)Discharge Time vs. Discharge Current AGM Operational Temperature AGM Storage Temperature 0 C to 40 C -15 C to 45 C Charge Discharge -15 C to 40 C Charge Voltage(V/Cell)Application Temperature Set Point Allowable Range Max.Charge Current Cycle Use 25 (77 )2.45 2.40~2.50 Standby 25 (77 )2.325 2.30~2.35 0.30C Final Discharge Voltage V/Cell 1.75 1.70 1.60 1.30 Discharge Current(A)0.2C>(A) 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C Charge Current & Final Discharge Voltage Cycle Life vs Depth of DischargeShelf Life & Storage Effect of Temperature on CapacityOpen Circuit Voltage vs Residual Capacity 1720 Hayden Drive Carrollton, Texas 75006 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com www.upgi.com Let UPG Power Your Life. UPG No. 40800 Maintenance-Free UB1270 PROJECT LOCATION PETSMART #1230 79 375 Hwy 111 La Quinta CA 92253 MM CONTRACTOR C-1065604 L Exp. 05/31/2022 SAT F AC E T O DL C-10 OC I C SNEE IR I OF N AE D T A AICR L L LC CODES ADOPTED BY CALIFORNIA AHJ California Building Code 2019 (Vol 1 & 2) California Existing Building Code 2019 California Fire Code 2019 California Mechanical Code 2019 BUILDING INFORMATION CONSTRUCTION TYPE: OCCUPANCY TYPE: STORIES:IN SCOPE: TOTAL SQ FT IN SCOPE: EXISTING FIRE ALARM SYSTEM: BUILDING FULLY SPRINKLERED: IIIB M/S-1 1 1 19,212 YES YES 1-877-776-1911 Web: adt.com/commercial REDLANDS CA 92374 1-877-776-1911 ADT COMMERCIAL #66898 25809 BUSINESS CENTER DR SUITE F REDLANDS CA 92374 SA#891115934 DR#34837 JOB#280681893 ® Scope of Work: ADT to provide wireless communicator BOSCH B444/B465 (SOLE Path) supervision by UL Listed Central Station to an existing fire alarm system. The cellular communicator will have a single 12vdc, 7amp hour battery capable of meeting/exceeding the 24hr standby period followed by 5 minutes of alarm at maximum system load as well. There will be no changes to the existing fire alarm system or occupancy classification of this space within this scope of work. The modification design is by Andrew Evans, NICET level III, APS 2087794, Staff Designer for ADT Commercial. Email: AndrewEvans@ADT.com. Ph. direct line: (682) 277-6570 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org November 10, 2021 ADT Commercial LLC 25809 Business Center Drive #F Redlands, CA 92374 Re: Fire Alarm System Modification Plan Review – PETSMART FA2021-0009 / 79395 HIGHWAY 111, LA QUINTA, CA 92253 The fire alarm system plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Function Test / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79395 HIGHWAY 111 PERMIT#: FA2021-0009 DATE ISSUED: 11/10/2021 DESCRIPTION: FA MOD – CELLULAR CONTRACTOR: ADT COMMERCIAL LLC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.