Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FA2021-0010
ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT ALARM MONITORING SERVICES INC OUTSIDE CITY LIMITS PALM DESERT CA 92255 (760)341-3593 salessupport@amscon nectme.com BILL TO ALARM MONITORING SERVICES 47794 42nd av Suite 1 Palm Desert CA 92260 (760)341-3593 DUANE@AMSCONNEC TME.COM CONTRACTOR ALARM MONITORING SERVICES INC OUTSIDE CITY LIMITS PALM DESERT CA 92255 (760)341-3593 salessupport@amscon nectme.com OWNER TA DESERT DEV 81570 CARBONERAS LA QUINTA CA 92253 (760)341-3593 CONDITIONS Description: FIRE SPRINKLER MONITORING SYSTEM Type: FIRE ALARM (WEB)Subtype: COMMERCIAL - SPRINKLER MONITORING Status: FINALED Applied: 11/18/2021 ECON Parcel No: 764200071 Site Address: 59140 MARBELLA LA QUINTA,CA 92253 Approved: 12/12/2021 KHET Subdivision: TR 37790 Block: Lot: 42 Issued: 12/13/2021 AHI Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/23/2022 KHET Valuation: $4,055.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Thursday, February 23, 2023 4:03:25 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2021-0010 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH-WIRE INSPECTION LIN 2/15/2022 2/15/2022 APPROVED FUNCTION TEST LIN 2/15/2022 2/15/2022 NOT READY contractor stated only wants prewire FIRE FINAL**LIN 2/15/2022 2/15/2022 NOT READY contractor stated only wants prewire SPRINKLER MONITORING LIN 2/15/2022 2/15/2022 NOT READY Contractor states only wants prewire ins FUNCTION TEST LIN 3/8/2022 3/8/2022 NOT READY FIRE FINAL**LIN 3/8/2022 3/8/2022 NOT READY FUNCTION TEST KHET 3/23/2022 3/23/2022 APPROVED FIRE FINAL**KHET 3/23/2022 3/23/2022 APPROVED DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS 101-0000-42421 0 $167.00 $167.00 12/13/21 WEB10128 634193524 49 CREDIT 944895 ECON FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS PC 101-0000-42420 0 $250.00 $250.00 12/13/21 WEB10128 634193524 49 CREDIT 944895 ECON Total Paid for FIRE FEES: $417.00 $417.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 12/13/21 WEB10128 634193524 49 CREDIT 944895 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 12/13/21 WEB10128 634193524 49 CREDIT 944895 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$433.00 $433.00 Printed: Thursday, February 23, 2023 4:03:25 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2021-0010 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/18/2021 Etrakit Contractor 1ST SUBMITTAL ENGINEERED FIRE PLANS Andalusia Design Center Fire Plans 8 x 11 10.7.21.pdf 1 DOC 11/18/2021 Etrakit Contractor 1ST SUBMITTAL CUT SHEETS_ SFM LISTING Andalusia Design Center Cutsheets SFM Listings (1).pdf 1 DOC 12/12/2021 KOHL HETRICK FA2021-0010 - APPROVED PLANS.pdf FA2021-0010 - APPROVED PLANS.pdf 1 DOC 12/12/2021 KOHL HETRICK FA2021-0010 - COA AND JOB CARD.pdf FA2021-0010 - COA AND JOB CARD.pdf 1 DOC 3/24/2022 KOHL HETRICK Andalusia Design Center - System Record of Completion - 3-23- 22.PDF Andalusia Design Center - System Record of Completion - 3-23- 22.PDF 1 BOND INFORMATION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 11/18/2021 12/6/2021 12/12/2021 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 11/18/2021 11/19/2021 11/18/2021 COMPLETE PARENT PROJECTS Printed: Thursday, February 23, 2023 4:03:25 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2021-0010 DEVICE LEGENDSYMBOLQTYMANUFACTURER PART NO DESCRIPTION CSFM1BOSCHF220-B612V/24V 4 WIRE SMOKE DETECTOR WITH 6 INCH BASE7300-1615:01051 BOSCH FMM-100SATKDIE CAST METAL FIRE ALARM MANUAL STATION SINGLEACTION7150-1615:02241 BOSCH FPD-7024 FIRE ALARM CONTROL PANEL 7165-1615:02271 BOSCH FPD-7024 MAIN BOARD FIRE ALARM CONTROL PANEL MAIN BOARD1 WHEELOCK MB-G10-24-RMOTORIZED BELL, 24 VDC, 10"7135-0785:01131 GENERIC WATERFLOW SWITCH 2 WATERFLOW SWITCH SUPPLIED BY OTHERS2 GENERIC TAMPER SWITCH TAMPER SWITCH SUPPLIED BY OTHERSFFACPFVWFCABLE AND WIRE LEGENDLABEL PART NOAWGRESISTANCE(Ω/KFT)DESCRIPTION TOTAL LENGTHA980 187.77 SOLID COPPER FPLR 18/218'B994143.07SOLID COPPER FPLR 14/26'Andalusia Disigne Center140 Marbella La Quinta CA 92253*These drawings are not approved for construction purposes until approval from AHJ1. THE SYSTEM SHALL BE A LOW VOLTAGE, POWER LIMITED CENTRAL STATION SIGNALING SYSTEM.2. EACH ZONE SHALL ANNUNCIATE AT THE F.A.C.P. AND CENTRAL STATION.3. CENTRAL STATION COMMUNICATION METHODS SHALL COMPLY WITH NFPA 72, SECTION 26.6.3.2.1.4 TRANSMISSION CHANNELS.4. SYSTEM SHALL HAVE PRIMARY POWER (120 VAC. 350 VA) FROM A 20 AMP DEDICATED SOURCE. IDENTIFIED AS A FIRE ALARM CIRCUIT. A LOCK OUT DEVICE SHALL BE PROVIDED ON ALL FIRE ALARM BREAKERS. THE SYSTEM SHALL BE PROVIDED WITH A MINIMUM 24 HOUR STANDBY BATTERY BACK UP.5. THE SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH NEC AND MANUFACTURER'S INSTRUCTIONS.6. ALL POWER LIMITED WIRING SHALL BE SEPARATED FROM NON-POWER LIMITED WIRING. ELECTRIC LIGHT POWER AND CLASS 1 CIRCUITS BY A MINIMUM OF 2 INCHES (REF. CEC. ARTICLE 760-52 (a)(1).7. ALL POWER LIMITED CIRCUITS SHALL BE PERMANENTLY IDENTIFIED AT THE DACT AND IN THE MAIN JUNCTION BOXES.8. THE SYSTEM SHALL UTILIZE U.L./NEC APPROVED POWER LIMITED FIRE CABLE, AND/OR THHN/THWN.9. FACP SHALL BE INSTALLED 72" ABOVE FINISHED FLOOR TO THE TOP OF THE BOX. REMOTE ANNUNCIATOR SHALL BE 60" ABOVE FINISHED FLOOR TO CENTER OF BOX.10. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND MANUFACTURER'S RECOMMENDATION FOR THE AREA OF INTENT.11. MANUAL PULL STATIONS SHALL BE INSTALLED 48" ABOVE FINISHED FLOOR TO THE CENTER OF THE BOX.12. LINE LOSS VOLTAGE FOR NOTIFICATION CIRCUITS SHALL NOT DROP LESS THAN 16VDC LOSS IN VOLTAGE AT END OF LINE.13. SUPERVISION:A. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. WIRE MUST BE CUT FOR IN AND OUT CONNECTIONS.B. COMMON ANNUNCIATION AND T-TAPPING IS PROHIBITED. DATA CIRCUITS EXCEPTED.C. ALL WIRING TO THE INITIATING NOTIFICATION DEVICES AND ANNUNCIATOR PANELS SHALL BE SUPERVISED.14. SYSTEM OPERATION:A. ACTIVATION OF ANY SMOKE DETECTOR, MANUAL PULL BOX, OR SPRINKLER WATER FLOW SWITCH;B. THE APPROPRIATE ZONE INDICATOR ON THE FACP TO VISUALLY DISPLAY: WHAT TYPE OF DEVICE WAS ACTIVATED AND FROM WHICH AREA THE ALARM WAS GENERATED.C. HORN/STROBES TO SOUND/FLASH IN A CODE 3 TEMPORAL PATTERN.D. THE APPROPRIATE ZONE ALARM SIGNAL SHALL BE TRANSMITTED TO THE APPROVED CENTRAL STATION FOR COMMUNICATION TO THE FIRE DEPARTMENT.E. THE SYSTEM SHALL BE ELECTRICALLY SUPERVISED SO THAT THE OCCURRENCE OF A SINGLE OPEN OR GROUND FAULT ON ANY FIELD WIRING, OR FAILURE OF PRIMARY POWER SUPPLY, WILL CAUSE A VISUAL “TROUBLE“ AT THE FACP.F. REMOTE ANNUNCIATOR AND A “TROUBLE“ SIGNAL SHALL BE TRANSMITTED TO THE APPROVED CENTRAL STATION FOR APPROPRIATE ACTION.15. THE OPERATION, MAINTENANCE, AND TESTING OF THE FIRE ALARM SYSTEM REQUIRED BY NFPA 72 AND LOCAL AHJ. AS PER LOCAL AHJ.16. 24 HOUR EMERGENCY RESPONSE NUMBER FOR THE APPROVED CENTRAL STATION SHALL BE ON FACP/DACT.17. NFPA 72 REQUIRED CERTIFICATE OF COMPLETION SHALL BE PROVIDED TO THE AHJ AT FIELD TEST.18. PER NEC, LOCK-OUT ON THE FIRE ALARM SYSTEM DEDICATED CIRCUIT BREAKER SERVING FIRE ALARM SYSTEM SHALL BE APPROVED AND COLORED “RED“.19. BACKUP BATTERIES SHALL BE PERMANENTLY MARKED WITH MONTH AND YEAR OF MANUFACTURER.20. SYSTEM SHALL HAVE 24 HOURS OF EMERGENCY STANDBY POWER FOLLOWED BY 5 MINUTES OF ALARM (SEE CALCULATIONS)21. THE FIRE ALARM SYSTEM SHALL BE CERTIFICATED OR PLACARDED AS A CENTRAL STATION SERVICE FIRE ALARM SYSTEM. A PERMANENT WEATHERPROOF SIGN SHALL BE PROVIDED IDENTIFYING THE FIRE ALARM CONTROL PANEL ROOM AND THE SIGNS MUST HAVE 2“ HIGH WHITE LETTERS ON A RED BACKGROUND.22. ALL SOUNDERS SHALL BE SET TO “TEMPORAL MODE“ AND STROBES SHALL BE SYNCHRONIZED.23. ALL WIRING, INITIATING DEVICES, AND ANNUNCIATOR PANELS SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF24. ANNUNCIATION (F/A PANEL TO SUPERVISE THE ANNUCIATOR PANEL, ALL CIRCUITS, AND INITIATING DEVICES).25. WIRING SHALL NOT BE LOOPED THROUGH DEVICES; WIRE MUST BE CUT FOR IN AND OUT.26. POINT AND COMMON ANNUNCIATION PROHIBITED. NON-ADDRESSABLE CIRCUITS T-TAPPING IS PROHIBITED.27. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED TO MANUFACTURERS SPECIFICATIONS.28. AUDIBILITY OF ALARM SHALL BE NO LESS THAN 15 DBA ABOVE AMBIENT SOUND.29. AREAS HAVING MORE THAN 2 STROBES IN THE FIELD OF VIEW SHALL BE SYNCHRONIZED.Project Name:Project Address:Designed By:Dace FrakerNicet Level III # 147197Project #:Scale:Date:Drawn By:Approved By:Sheet Name:Sheet Number:Drawing Revisions#DescriptionDateAuthority HavingJurisdiction StampDace Fraker10/7/2021FA-100CoverAndalusi Disigne Center140 Marbella La Quinta CA 92253EF1044Alarm Monitoring Service IncLicense#: 944895Mike PadillaGeneral NotesDescription: StoreOccupancy Type: Group BSprinklered: YesScope of Work: Fire alarm contractor to install a sprinkler monitoring system.Central Station Monitoring: Signals reported to central station via phone lines. Installing contractorto verify with general contractor and/or owner.Building InformationDevice Legend2018 INTERNATIONAL FIRE CODE2019 NFPA 72Applicable CodesDrawing Sheet IndexVicinity MapSheet Number Sheet Name Sheet Number Sheet NameFA-100CoverFA-200Floor PlanFA-300CalculationsFA-400RiserFA-500DetailsDevice IO NomenclatureCable & Wire LegendPx•Nx•00xPanel NumberCircuit NumberDevice NumberCandela RatingEnd of Line ResistorNAPPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST12/12/2021 8:00:58 AMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FA2021-0010Kohl Hetrick DEVICE LEGENDSYMBOLQTYMANUFACTURER PART NO DESCRIPTION CSFM1 BOSCHF220-B612V/24V 4 WIRE SMOKE DETECTOR WITH 6 INCH BASE7300-1615:01051 BOSCH FMM-100SATKDIE CAST METAL FIRE ALARM MANUAL STATION SINGLEACTION7150-1615:02241 BOSCHFPD-7024FIRE ALARM CONTROL PANEL7165-1615:02271 BOSCH FPD-7024 MAIN BOARD FIRE ALARM CONTROL PANEL MAIN BOARD1 WHEELOCK MB-G10-24-RMOTORIZED BELL, 24 VDC, 10"7135-0785:01131GENERIC WATERFLOW SWITCH 2 WATERFLOW SWITCH SUPPLIED BY OTHERS2 GENERIC TAMPER SWITCH TAMPER SWITCH SUPPLIED BY OTHERSFFACPFVWFCABLE AND WIRE LEGENDLABEL PART NOAWGRESISTANCE(Ω/KFT)DESCRIPTION TOTAL LENGTHA980 187.77 SOLID COPPER FPLR 18/218'B 994 14 3.07 SOLID COPPER FPLR 14/2 6'AV RM103MODULE (2)SALES OFFICE104MODULE (3)BREAK RM108FRIDGGFCIOPEN OFFICE110DESIGNER114DESIGNER115GFCITOILET A118HCTOILET B119TOILET C120DESIGN STUDIO C123HALL117STOR124ENTRY121FIRE RISER125DESIGNER111COPYHALL113GALLERY116EXIT123ASTOR112BDESIGN STUDIO B112GFCIMICROSALES OFFICE109STOR107BDESK112AEXIT107ADESIGN STUDIO A107SALES OFFICE105REFRESH106SALES ROOM102101GFCIWRGFCI HC HCGFCIGFCIGFCIFACPP1FP1•Z01•001 EOLFVP1•N2•001 EOLWFP1•Z02•001 EOLP1•Z03•001P1•Z03•002 EOLP1•AUX•001P1•Z04•001 EOL1 A1 B1 A1 A1 AProject Name:Project Address:Designed By:Dace FrakerNicet Level III # 147197Project #:Scale:Date:Drawn By:Approved By:Sheet Name:Sheet Number:Drawing Revisions#DescriptionDateAuthority HavingJurisdiction StampDace Fraker10/7/2021FA-200Floor Plan3/16" = 1' - 0"Andalusi Disigne Center140 Marbella La Quinta CA 92253EF1044Alarm Monitoring Service IncLicense#: 944895Mike PadillaFLOOR PLANN0'5'1'10'GRAPHIC SCALE P1 N2 POINT-TO-POINT REPORTCIRCUIT SETTINGS TOTALSStarting Calculation Voltage:20.4Max. Voltage Drop:0Min. Operational Voltage:16End Of Line Voltage:20.4Max. Circuit Current (A):2Voltage Drop Percent:0.00 %Wire Resistance (Ω/kFt):3.07Total Circuit Current (A):0.03Circuit Wiring Properties: 'B' 994 14 AWG, Solid Copper FPLR 14/2Total Circuit Length (Ft):4Spare Current (A):1.97Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):0.025Spare Current (A) Percent:98.50 %Device Label Part No.Description Device Current (A) Dist. From Previous (Ft)Voltage At Device Voltage Drop At Device Voltage Drop PercentRemaining Current (A) Resistance From Previous (Ω)Voltage Drop From PreviousP1•N2•001 EOL MB-G10-24-RMotorized Bell, 24 VDC, 10"0.03420.4 00.00 %0.03 0.025 0Calculation Methods:Resistance From Previous (Ω) = Wire Resistance (Ω/Ft) x 2 x Dist. From Previous (Ft)Voltage Drop From Previous = Resistance From Previous (Ω) x Remaining Current (A)P1 AUX POINT-TO-POINT REPORTCIRCUIT SETTINGS TOTALSStarting Calculation Voltage:20.4Max. Voltage Drop:0Min. Operational Voltage:16End Of Line Voltage:20.4Max. Circuit Current (A):1.4Voltage Drop Percent:0.00 %Wire Resistance (Ω/kFt):3.07Total Circuit Current (A):0.02Circuit Wiring Properties: 'B' 994 14 AWG, Solid Copper FPLR 14/2Total Circuit Length (Ft):2Spare Current (A):1.38Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):0.012Spare Current (A) Percent:98.57 %Device Label Part No.Description Device Current (A) Dist. From Previous (Ft)Voltage At Device Voltage Drop At Device Voltage Drop PercentRemaining Current (A) Resistance From Previous (Ω)Voltage Drop From PreviousP1•AUX•001 F220-B612V/24V 4 WIRE SMOKEDETECTOR WITH 6 INCH BASE0.02220.4 0 0.00 % 0.02 0.012 0Calculation Methods:Resistance From Previous (Ω) = Wire Resistance (Ω/Ft) x 2 x Dist. From Previous (Ft)Voltage Drop From Previous = Resistance From Previous (Ω) x Remaining Current (A) PANEL P1 (FPD-7024) BATTERY CALCULATION(SECONDARY POWER SOURCE REQUIREMENTS)STANDBY CURRENT (AMPS) SECONDARY ALARM CURRENT (AMPS)PANEL COMPONENTSQTYPART NO. DESCRIPTIONCURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A)TOTAL1 FPD-7024 MAIN BOARD Fire Alarm Control Panel Main Board0.20.20.380.38CIRCUIT SYMBOLQTYPART NO DESCRIPTIONCURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL (A)P1•Z011FMM-100SATKDie cast Metal Fire Alarm Manual Station Single Action0000P1•Z021WATERFLOW SWITCH 2 WATERFLOW SWITCH SUPPLIED BY OTHERS0000P1•N2 1 MB-G10-24-RMotorized Bell, 24 VDC, 10"000.030.03P1•Z032 TAMPER SWITCH TAMPER SWITCH SUPPLIED BY OTHERS0000P1•Z041F220-B612V/24V 4 WIRE SMOKE DETECTOR WITH 6 INCH BASE0000P1•AUX1F220-B612V/24V 4 WIRE SMOKE DETECTOR WITH 6 INCH BASE0.020.020.020.02TOTAL STANDBY (A)0.22TOTAL ALARM (A)0.43REQUIRED STANDBY TIME = 24 HOURSREQUIRED ALARM TIME = 5 MINUTESSECONDARY STANDBY LOAD (A)0.22245.28SECONDARY ALARM LOAD (A)0.430.080.04STANDBY AND ALARM SUBTOTAL (AMP HOURS)5.32DERATING FACTOR1.2SECONDARY LOAD REQUIREMENTS (AMP HOURS)6.38PROVIDE (2) 12V 7AH BATTERIES @ 24VDCFWFFVREQUIRED FIRE SAFETY CONTROLACTUATE AUDIBLE ALARM SIGNAL2 FIRE ALARM SYSTEM LOW BATTERYNOTIFICATION APPLIANCE CIRCUIT SHORTBUILDING MANUAL PULL STATIONS13141615OPEN CIRCUITGROUND FAULTSMOKE DETECTORS7891011123564FIRE ALARM SYSTEMINPUT/OUTPUT MATRIXSYSTEM INPUTSFIRE ALARM SYSTEM AC POWER FAILURE1ADCB2141615137981011123564TRANSMIT TROUBLE SIGNAL TO CENTRAL STATIONTRANSMIT FIRE ALARM SIGNAL TO CENTRAL STATIONJGFEIHLK1SYSTEM OUTPUTSNOTIFICATIONBCAHGFEDLKIJACTUATE AUDIBLE/VISIBLE TROUBLE SIGNAL AT FACP & ANNACTUATE BUILDING NOTIFICATIONACTUATE AUDIBLE/VISIBLE ALARM SIGNAL AT FACP & ANNWATERFLOWTAMPERTRANSMIT SUPERVISORY SIGNAL TO CENTRAL STATIONACTUATE AUDIBLE/VISIBLE SUPERVISORY SIGNAL AT FACP & ANNDISPLAY CHANGE OF STATUS P1 Z01 DEVICE SCHEDULETOTALSTotal Circuit Length (Ft)5Circuit Wiring Properties: 'A' 980 18 AWG, Solid Copper FPLR 18/2Distance measured using drawn segment lengths with 10.00 % additional length calculatedDevice Label Part No.Description Dist. From Previous (Ft)P1•Z01•001 EOL FMM-100SATKDie cast Metal Fire AlarmManual Station Single Action0'P1 Z02 DEVICE SCHEDULETOTALSTotal Circuit Length (Ft)61Circuit Wiring Properties: 'A' 980 18 AWG, Solid Copper FPLR 18/2Distance measured using drawn segment lengths with 10.00 % additional length calculatedDevice Label Part No.Description Dist. From Previous (Ft)P1•Z02•001 EOL WATERFLOW SWITCH 2WATERFLOW SWITCHSUPPLIED BY OTHERS6'P1 Z03 DEVICE SCHEDULETOTALSTotal Circuit Length (Ft)110Circuit Wiring Properties: 'A' 980 18 AWG, Solid Copper FPLR 18/2Distance measured using drawn segment lengths with 10.00 % additional length calculatedDevice Label Part No.DescriptionDist. From Previous (Ft)P1•Z03•001TAMPER SWITCHTAMPER SWITCH SUPPLIEDBY OTHERS9'P1•Z03•002 EOL TAMPER SWITCHTAMPER SWITCH SUPPLIEDBY OTHERS2'P1 Z04 DEVICE SCHEDULETOTALSTotal Circuit Length (Ft)22Circuit Wiring Properties: 'A' 980 18 AWG, Solid Copper FPLR 18/2Distance measured using drawn segment lengths with 10.00 % additional length calculatedDevice Label Part No.Description Dist. From Previous (Ft)P1•Z04•001 EOLF220-B612V/24V 4 WIRE SMOKEDETECTOR WITH 6 INCH BASE2'Project Name:Project Address:Designed By:Dace FrakerNicet Level III # 147197Project #:Scale:Date:Drawn By:Approved By:Sheet Name:Sheet Number:Drawing Revisions#DescriptionDateAuthority HavingJurisdiction StampDace Fraker10/7/2021FA-300CalculationsAndalusi Disigne Center140 Marbella La Quinta CA 92253EF1044Alarm Monitoring Service IncLicense#: 944895Mike Padilla FACPP1WFP1•Z02•001 EOLP1•Z03•001P1•Z03•002 EOLP1•AUX•001P1•Z04•001 EOLFVP1•N2•001 EOLFP1•Z01•001 EOL1A1A1A 1A1A1A1A1B 1B 1B 1B 1B1B 1B 1B 1B 1B 1B 1B1B1A 1A 1A 1A 1A 1A 1AProject Name:Project Address:Designed By:Dace FrakerNicet Level III # 147197Project #:Scale:Date:Drawn By:Approved By:Sheet Name:Sheet Number:Drawing Revisions#DescriptionDateAuthority HavingJurisdiction StampDace Fraker10/7/2021FA-400RiserAndalusi Disigne Center140 Marbella La Quinta CA 92253EF1044Alarm Monitoring Service IncLicense#: 944895Mike Padilla Project Name:Project Address:Designed By:Dace FrakerNicet Level III # 147197Project #:Scale:Date:Drawn By:Approved By:Sheet Name:Sheet Number:Drawing Revisions#DescriptionDateAuthority HavingJurisdiction StampDace Fraker10/7/2021FA-500DetailsAndalusi Disigne Center140 Marbella La Quinta CA 92253EF1044Alarm Monitoring Service IncLicense#: 944895Mike PadillaORANGECOLOR46.8KNUMBER62ND BAND50BLACKNO.560ORANGE1KN.T.S.END-OF-LINE RESISTOR COLOR CODEGREEN1 WATT9VALUEBLUEPLACED 3'-0" FROM ALL AIR5%BLUE8BLUEYELLOW147010%ORANGE4TH BANDBROWNNOTE: DETECTORS SHALL BE1 WATT1/2 WATTDIFFUSERS10KZEROS(E.O.L.R.)*DETAIL IS TYPICAL FOR DETECTORS AND NOTIFICATION DEVICESBOX HANGERSEISMIC WIRE TO1ST BANDN.T.S.GRAYDIFFUSERSGYP. BOARD DEVICEYELLOWBLACKBLACKREDSUSPENDED CEILINGGOLDBLACKBROWNVALUEVIOLET4X4 J-BOXTOLERANCEGOLDBROWNGOLDOHMSILVERYELLOWBOX HANGER SUPPORT3-0 EXTENSION RING1 WATTORANGESTRUCTURE ABOVEVIOLETGYP. BOARD CEILINGRED END-OF-LINE RESISTOR COLOR CODEDETECTOR BASEWIRE RUN DETAIL - J-BOX DETAILGOLD21 WATT3.3KGOLDNOTE: DETECTORS SHALL BEGREEN1/2 WATTGOLDTHROUGH WALL PENETRATION DETAILSWHITESUSPENDED CEILING DEVICEDETECTOR BASE1 WATTREDBROWN100KGOLDPLACED 3'-0" FROM ANY AIR*DETAIL IS TYPICAL FOR DETECTORS AND NOTIFICATION DEVICES3RD BANDWIRINGREDDETECTOR HEAD3GRAY3-0 EXTENSION RING7DETECTOR HEADN.T.S.BROWNCOLORNUMBERWIRING4X4 J-BOXBROWNWATTAGEGOLDCOLOR CODENUMBERVALUEOFTOLERANCEA.F.F.FOR DEVICE HEIGHT AND CANDELA SETTING.DIFFUSER72" A.F.F.MOUNT DEVICE 90"FINISHEDNEVERFINISHEDL4"SMOKE/HEAT1. WALL MOUNTED APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80" AND NOT GREATER THAN 96"DETECTORHERE12"MINIMUMABOVE FINISHED FLOOR. (NFPA 72 SECTION 18.5.5.1)NO LOWERMOUNT ATDEVICE MOUNTING ELEVATIONSACCEPTED HERE80"48" A.F.F.3' MIN.NOTES:MAXIMUMWALL MOUNTEDCEILING MOUNTED(SEE NOTE 2)AS PER MANUFACTURES RECOMMENDATIONSFLOORSMOKE/HEATENCLOSUREA/C SUPPLYCEILINGCEILINGCEILING MOUNT HORN/STROBES17.7.3.2.12. IF CEILING HEIGHTS ALLOW, AND UNLESS OTHERWISE PERMITED, WALL MOUNT APPLIANCES SHALL HAVE THEIR TOPS ABOVE FINISHED96"OR 6" BELOWAND STROBES TO BE MOUNTEDWALLNFPA 72 2013A.F.F.TO TOP OFCABOVE FINISHED FLOORTO TOP OF17.6.3.1.3.1,4"(SEE NOTE 1)6" MINIMUMENCLOSUREDETECTORCEILINGMOUNT AT(SEE NOTE 1)60" A.F.F.N.T.S.FLOOR AT HEIGHTS NOT LESS THAN 90" AND BELOW THE FINISHED CEILING AT DISTANCES OF NOT LESS THAN 6". (NFPA 72 2030 SECTION 18.4.8.1)DEVICE WALL MOUNT DETAIL Fire Alarm Systems | F220‑B6 Conventional detector bases F220‑B6 Conventional detector bases www.boschsecurity.com u Easy installation u Interchangeable detector heads u UL listed when used with a detector from the F220 family The F220‑B6 Detector Bases work with the F220 Photoelectric Smoke and Heat Detectors. The F220‑B6 is a 12 V or 24 V base for two‑wire loops. The other bases in this family are 12 V or 24 V bases for four‑wire loops. Certifications and approvals Region Regulatory compliance/quality marks USA UL UL 268, Smoke Detectors for Fire AlarmSystems UL UL 521, Heat Detectors for Fire Protec-tive Signaling Systems FM F220-B6 Family CSFM see www.boschsecurity.com (the Boschwebsite) NYC-MEA (117-05-E) MSFM permit #2200 Sep 2008 Canada ULC CAN/ULC-S529, Smoke Detectors forFire Alarm Systems Region Regulatory compliance/quality marks ULC CAN/ULC-S530, Heat Actuated Fire De-tectors for Fire Alarm Systems Hong Kong HKFSD J-002/C/067 Installation/configuration notes Compatibility Information Two‑wire: Bosch Security Systems, Inc. makes no claim written, oral, or implied that the F220‑B6 Detector Bases work with any two‑wire control panels except those specified in the Two‑wire Detector/ Control Panel Compatibility List Technical Service Note. Four‑wire: Compatible with all UL Listed four‑wire control panels. Refer to the control panel's Installation Instructions for proper end‑of‑line (EOL) resistor selection. Detectors: Compatible with the following F220 Series Detector Heads: • F220‑P Photoelectric Smoke Detector • F220‑PTH Photoelectric Smoke Detector with +135°F (+57°C) Heat Sensor • F220‑PTHC1 Photoelectric Smoke Detector with +135°F (+57°C) Heat Sensor and Carbon Monoxide Sensor Enhancement1 • F220‑135 Electronic Rate‑of‑Rise, Fixed Temperature +135°F (+57°C) Heat Detector • F220‑135F Electronic Fixed Temperature +135°F (+57°C) Heat Detector • F220‑190F Electronic Fixed Temperature +190°F (+88°C) Heat Detector 1 The F220‑PTHC detects carbon monoxide (CO) as a component of a fire. It is not a CO detector and cannot activate an alarm in the presence of CO only. Mounting Considerations Depending on local regulations, surface mount the bases using anchors, mollies, or wing nuts; or mount the bases directly on four‑inch square or octagonal electrical boxes or single‑gang switch boxes. Notice The electrical box must be large enough to accommodate the number and size of conductors specified by the National Electrical Code or any local authorities having jurisdiction (AHJ). Wiring Considerations In a two‑wire system, the maximum loop length depends on the number of detector bases on the loop, the wire size, and the control panel specifications. Refer to the control panel's installation instructions for specific wiring information. In a four‑wire system, the maximum loop length and number of bases that can be placed on a loop depend on the voltage drop on the power circuit. Use standard voltage drop calculations to ensure that the last detector on the loop has at least 10 V. Technical specifications Electrical Current Alarm B6 Limited to 20 mA minimum at 8.5 VDC. 35 mA maximum at 32 VDC B6R, B6E 13.5 mA at 12 VDC, 16.5 mA at 24 VDC, 19 mA at 30 VDC B6C 0.5 A at 125 VAC, 1.0 A at 30 VDC for resistive loads Standby All models 0.09 mA at 12 VDC, 0.10 mA at 24 VDC, 0.12 mA at 32 VDC Relays B6R Ratings Type 0.5 A at 100 VDC Form A [normally-open (NO), closes on alarm] B6C Ratings Type 0.5 A at 125 VAC, 1.0 A at 30 VDC Form C [one set of normally-open, common, normally-closed (NO‑C‑NC) contacts] B6E, alarm Ratings Type 0.5A at 125 VDC, 1 A at 30 VDC Form A [normally-open (NO), closes on alarm] B6E, EOL Ratings 0.5 A at 100 VDC for resistive loads Environmental Relative Humidity: Up to 95%, non‑condensing Temperature (operating): +32°F to +100°F (0°C to +38°C) Mechanical Color Off-white Dimensions (ØxH) 6.69 in. x 0.82 in. (170 mm x 20.88 mm) Material Fire‑resistant plastic Weight B6 Gross Net 7.76 oz. ( 0.22 kg) 6.70 oz. (0.19 kg) B6R Gross Net 8.47 oz. (0.24 kg) 7.41 oz. (0.21 kg) B6C Gross Net 8.47 oz. ( 0.24 kg) 7.41 oz. (0.21 kg) B6E Gross Net 6.35 oz.. (0.18 kg) 5.64 oz.. (0.16 kg) Trademarks All hardware/software product names used in this document are likely to be registered trademarks and must be treated accordingly. 2 | F220‑B6 Conventional detector bases Ordering information F220-B6 Base, 2-wire, 12/24V Standard base for two‑wire (12 VDC or 24 VDC system) applications. The base works with the F220 smoke detectors and heat detectors. Order number F220-B6 F220-B6R Base with form A relay, 4-wire, 12/24V Standard base for four‑wire (12 VDC or 24 VDC) detector systems. The base works with the F220 smoke detectors and heat detectors. Order number F220-B6R F220-B6C Base, 4-wire, form A & C relays, 12/24V Four‑wire base with a normally‑open (NO) alarm loop relay and a set of auxiliary contacts (Form C). The base works with the F220 smoke detectors and heat detectors. Order number F220-B6C F220-B6E Base, end-of-line relay, 4-wire 12/24V Four‑wire base with a normally‑open (NO) alarm relay and an EOL power supervision relay. The base works with the F220 smoke detectors and heat detectors. Order number F220-B6E Accessories DRA-5 Remote indicator plate, 5V Provides remote annunciation of alarms for a number of Bosch smoke and heat detectors Order number DRA-5 PAM-4 Relay module, form C, 10A 12/24V One set of 10.0 A, Form C contacts that can be energized across a range from 9 VDC to 40 VDC Order number PAM-4 3 | F220‑B6 Conventional detector bases Represented by: Europe, Middle East, Africa:Germany:North America:Asia-Pacific: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia © Bosch Security Systems 2018 | Data subject to change without notice 2707760011 | en, V10, 13. Dec 2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7300-1615:0105 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Peter Namisnak (585) 678-3655 Fax (585) 678-3263 Email: peter.namisnak@us.bosch.com DESIGN: Models F220-B6(2-wire); F220-B6C, -B6E, -B6R and *-B6RS(4-wire) detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with separately listed Models F220-135 series (CSFM Listing No. 7270-1615:108) heat detectors; Models F220-PC series (CSFM Listing No. 7272-1615:107) or Models F220-P series (CSFM Listing No. 7272-1615:106) photoelectric smoke detectors and compatible fire alarm control units. Refer to listee’s Installation Instruction Manual for details. *Rev. 04-06-2005 July 01, 2021Date Issued:Listing Expires June 30, 2022 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Fire Alarm Systems | FMM‑100 Family Die‑cast Metal Fire Alarm Manual Stations FMM‑100 Family Die‑cast Metal Fire Alarm Manual Stations www.boschsecurity.com u Single or dual action u Terminal connections u Gold‑plated alarm contacts for corrosion resistance u Surface or weatherproof back boxes The FMM‑100 family are versatile, high‑quality, metal fire alarm manual stations. Single‑action or dual‑action models are available. All models come with a key lock and contain gold‑plated contacts to resist corrosion. Functions Single-action Operation When the bar on the front of the manual station is pulled, it latches open and is easily visible from 50 ft. (15 m). Reset the activation bar by opening the manual station with the key and placing the activation bar in its normal upright position. An optional scored acrylic break rod is available. Double-action Operation With the dual‑action configuration the upper bar on the front of the manual station rotates inward allowing the activation bar to be grasped and operated by a single hand. Certifications and approvals Region Regulatory compliance/quality marks USA UL UL 38, Manual Signaling Boxes for FireAlarm Systems CSFM see www.boschsecurity.com (the Boschwebsite) NYC-MEA 382-94-E, Vol. VI Canada ULC CAN/ULC-S528, Manual Stations forFire Alarm Systems, Including Accesso-ries Installation/configuration notes Compatibility Information These manual stations are compatible with all Bosch Security Systems, Inc. Fire Alarm Control Panels. Mounting Considerations These manual stations can be surface mounted on either the FMM‑100BB‑R Surface‑mount Back Box or the FMM‑100WPBB‑R Weatherproof Back Box. They can also be flush mounted on a standard single‑gang back box. Notice When properly mounted on the FMM‑100WPBB‑R Weatherproof Back Box, these manual stations meet UL requirements for outdoor use. To comply with ADA standards, the manual station must be less than 48 in. (1.2 m) above the floor for front wheelchair access and less than 54 in. (1.3 m) above the floor for side wheelchair access. Technical specifications Electrical Switch rating 1 A at 30 VDC or 125 VAC Environmental Relative humidity 90% at +100°F (+38°C) Temperature (operating) -40°F to +150°F (-40°C to +66°C) Mechanical Color Red Dimensions (H x W x D) 4.75 in. x 3.25 in. x 1.1 in. (12 cm x 8.3 cm x 2.8 cm) Material Die‑cast metal Trademarks All hardware/software product names used in this document are likely to be registered trademarks and must be treated accordingly. Ordering information FMM-100SATK Manual station, single-action, red Versatile, high‑quality, metal single‑action fire alarm manual station with key lock and gold‑plated contacts Order number FMM-100SATK FMM-100SATK-NYC Manual station, single-action for NYC Versatile, high‑quality, metal single‑action fire alarm manual station for New York City with key lock and gold‑plated contacts Order number FMM-100SATK-NYC FMM-100DATK Manual station, dual-action, red Versatile, high‑quality, metal dual‑action fire alarm manual station with key lock and gold‑plated contacts Order number FMM-100DATK Accessories D102 Replacement key for D101 lock set The D102 is a replacement key for locks stamped with 1358. Order number D102 FMM-100BB-R Surface backbox, 4.75x3.25x2.25", red Red surface-mount metal back box Order number FMM-100BB-R FMM-100WPBB-R Weatherproof backbox 4.75x3.25x2.25" red Red cast‑metal weatherproof back box Order number FMM-100WPBB-R FMM-100GR Break rods, scored acrylic, 12pcs Scored acrylic rods (12 per package) Order number FMM-100GR 2 | FMM‑100 Family Die‑cast Metal Fire Alarm Manual Stations Represented by: Europe, Middle East, Africa:Germany:North America:Asia-Pacific: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia © Bosch Security Systems 2019 | Data subject to change without notice 2708627339 | en, V5, 17. Jan 2019 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7150-1615:0224 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE:BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Peter Namisnak (585) 678-3655 Fax (585) 678-3263 Email: peter.namisnak@us.bosch.com DESIGN: Model FMM-100, followed by DAT (Dual Action with terminal strip) or SAT (Single Action with terminal strip) may be followed by K or K-NYC (key lock with single contact) or 2CK (Key lock with dual contacts) noncoded manual pull stations. FMM-100BB indoor back box, Suitable for outdoor use when installed with Model FMM-100WPBB back box. *FMM-100DBB-R surface mount deep back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:30 VDC, 125 VAC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. Only Models FMM-100DATK, -100SATK, -100SAT2CK manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF:7150-1408:0107 *Revised 09-01-2016 dc July 01, 2021Date Issued:Listing Expires June 30, 2022 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Fire Alarm Systems | FPD‑7024 Fire Alarm Control Panels FPD‑7024 Fire Alarm Control Panels www.boschsecurity.com u Four initiating zones (expandable to eight); up to 20 two‑wire smoke detectors per zone u Programmable through keypads or remote programming software (RPS) through a Conettix interface module u Two notification appliance circuits (NACs) on board with a shared internal regulated 24 VFWR, 4 A NAC power supply u Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module The FPD‑7024 Fire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. They are listed by UL for central station, local, auxiliary, and remote station systems. The FPD‑7024 FACPs support four on‑board initiating zones that can be expanded to eight using the FPC-7034. Each initiating zone supports two‑wire and four‑wire detectors configurable as Class A , Style D or Class B, Style B loops. Each zone can support up to 20 two‑wire detectors, or any number of four‑wire detectors depending on available power. Each FACP has a built‑in digital fire alarm communicator transmitter (DACT). Enhance the FPD‑7024 conventional system features by adding a D7039 Multiplex Expansion Module. Adding a D7039 Multiplex Expansion Module to the FPD‑7024 turns the conventional FACP into an addressable FACP. The D7039 adds up to 247 addressable points to the base system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases the number of programmable relay outputs from 19 to 59 and expands system users to 100. Functions Notification Appliance Circuits (NACs) Two Class A, Style Z or Class B, Style Y NACs provide up to 4 A of regulated 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, California March, steady, pulsed, and synchronized output for Wheelock, Gentex, or System Sensor notification appliances. User Interface A viewing port in the locked control panel enclosure door shows the system status light‑emitting diodes (LEDs) and liquid‑crystal display (LCD) while maintaining system keypad security. Unlocking the enclosure door provides access to the system controls for silencing off‑normal conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all FMR‑7033 LCD Keypads connected to the system. Organized Event Display Sorts alarm, trouble, and supervisory events into categories and allows scrolling through specific events. History Buffer The system stores events in a 99‑event history buffer. Notice The number of events that can be stored in the history buffer increases to 499 with the addition of a D7039 Multiplex Expansion Module. Central Station Reporting The FPD-7024 FACPs send reports to two telephone numbers (or, if a Conettix interface module is installed, IP addresses) to an appropriate Conettix receiver at the central station with full single, double, and backup reporting. The panel supports communication in BFSK, SIA, Contact ID, Modem IIIa2, and 4/2 or 3/1 Tone Bursts. Dirty Smoke Detector Monitoring All on‑board zones and FPC‑7034 zones are continuously monitored for smoke detectors signaling a dirty condition using the Bosch Chamber Check feature and CleanMe protocol. If a detector's smoke chamber is dirty, the detector sends a CleanMe signal on the two‑wire loop or a dirty detector signal on the addressable loop. The control panel annunciates that there is a dirty detector on the loop or the address. The Chamber Check feature signals a dirty smoke chamber using the LED on the detector head. Accessories The FPD‑7024 enclosure has space for additional accessory modules and two D1218 (18 Ah) batteries or two D126 (7 Ah) batteries. Certifications and approvals Region Certification USA UL UOJZ: Control Units, System (ANSI/UL864) FM FPD-7024 CSFM see our website FCC ESVAL04B7024 FDNY-CoA #6173 Installation/configuration notes Compatible Products The following products are compatible (refer to the product datasheet for country‑specific certifications/ approvals) with the FPD‑7024 FACP: Category Product ID and Description Batteries and Power Supplies D126 12 V, 7 Ah battery D1218 12 V, 18 Ah battery FPP‑RNAC‑8A‑4C Remote NAC power supply Detectors For two‑wire detector compatibility, refer to FPD‑7024 Smoke Detector Compatibility List Technogram (P/N: F01U010790) Keypads and Annunciators D7030X Eight‑point LED annunciator (eight red) D7030X‑S2 Eight‑point LED annunciator (two yellow, six red) D7030X‑S8 Eight‑point LED annunciator (eight yellow) D7032 Eight‑point LED annunciator expander (eight red) FMR‑7033 LCD fire system keypad FMR‑7036 LCD annunciator Modules D132B Smoke detector reversing relay module D184A Local energy kit D185 Reversing polarity module D275 EOL power supervision module FPC‑7034 Four‑point expander D7039 Multiplex expansion module Option Bus Devices D7035 Octal relay module D7035B Octal relay module in box DX4010V2 USB/serial interface module DX4020 Network interface module B420 Ethernet communicator B426 Ethernet communication module B440 Conettix plug‑in cellular B441 Conettix plug‑in cellular B442 Conettix plug‑in GPRS cellular B443 Conettix plug‑in HSPA+ cellular B450 Conettix plug‑in communicator interface ITS-DX4020-G GPRS/GSM communicator NAC Devices Refer to FPD‑7024 Device Compatibility List Technogram (P/N: F01U010791) The following additional products are compatible with the FPD‑7024 Addressable FACPs: Category Product ID and Description Detector Heads and Bases D7050 Addressable Photoelectric Smoke Detector Head D7050TH Addressable Photoelectric Smoke and Heat Detector Head D7050‑B6 Detector Base Modules D7042 Multiplex eight‑input remote module 2 | FPD‑7024 Fire Alarm Control Panels D7042B Multiplex eight‑input remote module in box D7044 Multiplex single‑input module D7044M Mini multiplex single‑input module D7048 Multiplex octal driver D7048B Multiplex octal driver in box D7052 Multiplex dual‑input module D7053 Multiplex input‑output module Pull Stations FMM‑7045 Single‑action manual station FMM‑7045‑D Double‑action manual station Parts included FPD-7024 Quant.Component 1 FPD‑7024 board in a static‑resistant bag 1 Enclosure 1 Lock set with two #1358 (D102) keys (P/ N: F01U083084) 1 Transformer (P/N: F01U033706) 6 2.21 kΩ end‑of‑line (EOL) resistors (P/N: F01U034504) 1 Hardware pack 1 Literature pack Notice For the FPD‑7024 to be addressable, a D7039 Multiplex Expansion Module must be installed. The D7039 is purchased separately. FPD-7024-LC Quant.Component 1 FPD‑7024 board in a static‑resistant bag 1 Hardware pack 1 Literature pack FPD‑7024‑LT (Latin America only) Quant.Component 1 FPD‑7024 board in a static‑resistant bag 1 Enclosure 1 Lock set with two #1358 (D102) keys (P/ N: F01U083084) 6 2.21 kΩ end‑of‑line (EOL) resistors (P/N: f01U034504) 1 Hardware pack 1 Literature pack FPC-7024-FK1 Quant.Component 1 FPD‑7024 FACP 1 F220-B6E 6-in. (15.24-cm) diameter, 4-wire base with EOL relay 1 F220-P photoelectric spot smoke detector 1 SS-P2R Two‑wire Horn Strobe 1 FMM-100SATK manual station (red) 2 D162@24 2-ft (60.96-cm) dual modular phone cord 2 D166@24 RJ31X phone jack Technical specifications Electrical Current (alarm)*:380 mA Current (standby)*:200 mA Power (primary):120 VAC , 1.2 A maximum, 60 Hz or 240 VAC , 0.75 A maximum, 50 Hz * For product‑specific current values, see the product’s Installation Instructions. Environmental Environment:Indoor, dry Relative Humidity:Up to 95%, non-condensing Temperature (operating):+32°F (0°C) to +120°F ( +49°C) Mechanical Properties Color:Red Dimensions (HxWxD):20.8 in. x 15 in. x 4.3 in. (52.8 cm x 38.1 cm x 10.9 cm) Material:Cold-rolled steel Base: 18 gauge (1.2 mm) Cover: 19 gauge (1.1 mm) Indicating Device Circuits (IDC) Current:44 mA maximum per loop Line resistance:150 Ω Voltage:24 VDC nominal Outputs NAC:24 VDC nominal, 4 A maximum On-board Relays:Three Form C contacts rated at 5 A, 28 VDC Off-board Relays:Up to two D7035 Octal Relay Modules with each providing eight Form C relay outputs; contacts rated at 5 A, 28 VDC In an addressable system, up to 20 D7053 Multiplex Input-Output Modules are allowed per bus for a total of 40 3 | FPD‑7024 Fire Alarm Control Panels Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. Ordering information FPD-7024 FACP Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone Order number FPD-7024 FPD-7024-LC FACP without Enclosure and Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone Order number FPD-7024-LC FPD-7024-LT FACP without Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone. Available only in Latin America. Order number FPD-7024-LT Accessories FPC-7024-FK1 Basic Fire Panel Kit Four-zone FACP with one four-wire photoelectric smoke detector and base with EOL relay, one two‑wire horn/strobe, one manual station, and two RJ31X phone jacks with dual modular phone cords. Order number FPC-7024-FK1 D102 Replacement Key Replacement key (#1358) for the D101 lock. Order number D102 4 | FPD‑7024 Fire Alarm Control Panels Represented by: Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Bosch Security Systems 2014 | Data subject to change without notice 2692228235 | en, V17, 18. Dec 2014 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7165-1615:0227 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE:BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Peter Namisnak (585) 678-3655 Fax (585) 678-3263 Email: peter.namisnak@us.bosch.com DESIGN: Model FPD-7024 fire alarm control unit. Power limited, local, automatic, manual, coded, noncoded, remote station (PPU), proprietary (PPU), central station (PPU), waterflow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: FPD-7024; Control Unit FPC-7034; 4-Zone Expander FMR-7033, FMR-7036; Keypad D7035, D7035B; Expanded Relay Module D185; Reverse Polarity Module D7039, *FPE-7039; MUX Expander D7042, D7042B, D7044, D7044M, D7052, D7053; Mulitplez Expander Module D7048, D7048B; Octal Driver Module B440, B441, B443; Cellular Modules B450; Interface Module *FLM-7024-ISO; MUX Bus Isolator Module RATING:120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee’s printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee’s name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee’s Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Revsion 02-15-17 gt July 01, 2021Date Issued:Listing Expires June 30, 2022 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Motor bells Description The Wheelock MB motor bells provide a specifically designed motor bell for fire and life safety alarm systems. The Wheelock MB bells include higher dBA, low current draw, built-in trimplate for semi-flush mounting, low frequency aluminum shells, and low RFI noise. The motor for MB bells is a durable, high-torque permanent magnet motor selected for its high performance and long life. These DC vibrating MB motor bells are offered in 6” and 10” shell sizes in both 12 and 24 VDC models. The RSSP Sync/Non-Sync retrofit plates are used in conjunction with the MB motor bell when combination appliances are required. The RSSP retrofit plates are available with either multi-candela or single candela strobes and easily mount to a 4” square or Wheelock SBL-2 backbox. All RSSP strobe appliances meet or exceed the requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard for Accessible and Usable Buildings and Facilities), ADA (Americans with Disabilities Act), UL Standard 1971 (Signaling Devices for the Hearing Impaired). The RSSP retrofit plates may be synchronized when installed with the Wheelock Series DSM, Sync Modules or Wheelock Power Supplies with Wheelock patented sync protocol. Wheelock synchronized strobes offer an easy way to comply with ADA requirements concerning photo-sensitive epilepsy. RSSP REMOTE PLATE 10”BELL 6”BELL Technical Data TD450055EN Effective April 2019 Supersedes September 2016 Wheelock MB 2 Technical Data TD450055EN Effective April 2019 EATON www.eaton.com Wheelock MB Features & benefits • Meets OSHA 29 Part 1910.165 • High sound output with low current draw • Low frequency aluminum shells for better audibility through walls, doors and other structures • 6” and 10” shell sizes in 12 or 24 VDC models • Integral RFI suppression to minimize included noise on the NAC circuit • Mounting options for surface, semi-flush, outdoor, and concealed conduit installation • Built-in trimplate makes semi-flush mounting simpler and less expensive • Screw terminals permit fast in-out field wiring of #12 to #18 AWG wire • Polarized for DC supervision of NAC circuits • Operates on filtered or unfiltered DC • For combined audible (bell) and visual signaling, convenient retrofit plate assemblies are available with Multi-Candela or Single candela strobes (Refer to Fire Alarm Products Catalog for Series RSSP Sync/Non-Sync Strobes specifications and technical information) Note:N All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Approvals & compliances • Approvals include: UL Standard 464, CAN/ULC S525, Factory Mutual (FM), California State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP) • Meets OSHA 29 Part 1910.165 Drawings ø10.0 2.37 Figurt 1. MB-G10 frNno and sidt vitws 2.37ø6.0 Figurt 2. MB-G6 frNno and sidt vitws Tablt 1. SptcificaoiNns and Nrdtring infNrmaoiNne: MB mNdtls Model Number Order Code Shell Size Input Voltage (VDC)Average RMS Current UL Max a dBA @ 10 ft.Mounting Options MB-G6-12-R 3942 6”12 0.060 0.090 92 D, E, J, K, N, O, P, R, S MB-G6-12-S 4221 6”12 0.060 0.090 MB-G6-24-R 3941 6”24 0.030 0.040 MB-G6-24-S 4222 6”24 0.030 0.040 MB-G10-12-R 3944 10”12 0.060 0.090 MB-G10-12-S 4223 10”12 0.060 0.090 MB-G10-24-R 3943 10”24 0.030 0.040 MB-G10-24-S 4224 10”24 0.030 0.040 a RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Notse:N 1. Typical dBA at 10 feet is measured in an anechoic chamber. Notse:N 2. For bells all 12 VDC models are UL rated for 9.0 to 15.6 VDC and all 24 VDC models for 18.0 to 31.0 VDC. Eaton is a registered trademark. All other trademarks are property of their respective owners. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 www.eaton.com/massnotification © 2019 Eaton All Rights Reserved Printed in USA Publication No. TD450055EN April 2019 Technical Data TD450055EN Effective April 2019 Wheelock MB Tablt 2. SptcificaoiNns and Nrdtring infNrmaoiNne: RSSP mNdtls Model Number Order Code Nominal Voltage (VDC)Strobe Candela Average Current (AMPS) at Listed VDC UL Max a Mounting Options b RSSP-24MCW-FR 9402 24 15/30/75/110 0.041/0.063/0.109/0.140 0.060/0.092/0.165/0.220 D, E, Z RSSP-241575W-FR 7793 24 15 (75 on-axis)0.060 0.090 D, E, Z RSSP-121575W-FR 7798 12 15 (75 on-axis)0.152 0.255 D, E, Z a RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. b Refer to data sheet TD450028EN for mounting options. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters’ Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and engineers specifications The alarm appliances shall be Wheelock MB vibrating motor bells or approved equal. They shall be UL Standard 464 listed for Fire Protective Service and CAN/ULC S525 listed (Audible Signaling Devices for Fire Alarm and Signaling Systems, including Accessories). Shells shall be aluminum in 6” or 10” diameter. Sound output at 10 feet shall be 92 dBA. The bells shall incorporate a permanent magnet motor and sup- pression circuitry to minimize RFI. They shall include a built-in trimplate for semi-flush mounting to a standard 4” square backbox or surface mounting to Wheelock’s indoor BB backbox or outdoor WBB backbox. For bell strobe applications, retrofit plates Wheelock RSSP with multi-candela or single candela strobes shall be used. All bell models shall be polarized for line supervision and shall have screw terminals for in/out field wiring of #12 to #18 AWG wire. Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be textured enamel. Note:N Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock, Inc., dba Eaton, standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3-YEAR WARRANTY CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7135-0785:0113 Page 1 of 1 CATEGORY: 7135 -- AUDIBLE DEVICES LISTEE:Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Thomas Conover (941) 487-2336 Email: thomaslconover@eaton.com DESIGN: Model MB series bells and Model MBS series bell/strobes. Models MB are suitable for outdoor use when used with Model WBB backbox. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer’s Installation Manual for details. *Rev. 06-13-2006 July 01, 2021Date Issued:Listing Expires June 30, 2022 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org December 12, 2021 Alarm Monitoring Services 47794 42nd Ave #1 Palm Desert, CA 92260 Re: Monitoring Fire Alarm System Plan Review – ANDALUSIA SALES CENTER FA2021-0010 / 59140 MARBELLA, LA QUINTA, CA 92253 The fire alarm system plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Function Test / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 59140 MARBELLA PERMIT#: FA2021-0010 DATE ISSUED: 12/12/2021 DESCRIPTION: ANDALUSIA SALES CENTER CONTRACTOR: ALARM MONITORING SERVICES INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.