Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FA2022-0002
ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT Dalton Ammann 22405 La Palma Ave Yorba Linda CA 92887 (714)957-5750 knguyen@westcoastfir einc.com CONTRACTOR WEST COAST FIRE & INTEGRATION, INC 22405 LA PALMA AVE YORBA LINDA CA 92887 (714)957-5750 INFO@WESTCOASTFIR EINC.COM OWNER LA QUINTA SPC 3255 W MARCH LN 4TH FL STOCKTON CA 92253 (714)957-5750 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 1/7/2022 1/7/2022 SENT BL APPLICATION CONDITIONS Description: NEW SPRINKLER MONITORING SYSTEM Type: FIRE ALARM (WEB)Subtype: COMMERCIAL - SPRINKLER MONITORING Status: FINALED Applied: 1/7/2022 EPRS Parcel No: 600390011 Site Address: 79120 CORPORATE CENTER DR LA QUINTA,CA 92253 Approved: 2/4/2022 KHET Subdivision: PM 29351 Block: Lot: 1 Issued: 2/4/2022 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 4/7/2022 KHET Valuation: $9,300.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Friday, March 03, 2023 2:38:43 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2022-0002 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH-WIRE INSPECTION KHET 4/4/2022 4/4/2022 APPROVED DUCT DETECTORS/VELOCITY KHET 4/4/2022 4/4/2022 APPROVED SEE NOTES GC to have HVAC provide certification of audit of confirming the sensing tubes are pointed the correct direction. SPRINKLER MONITORING KHET 4/4/2022 4/4/2022 NOT READY No fee Sprinkler contractor was not present and the system was drained. Unable to flow test. Will need reinspection. FIRE FINAL**KHET 4/4/2022 4/4/2022 NOT READY FINAL**KHET 4/6/2022 4/6/2022 CANCELED DAVID ALFORD REQUESTED TO CANCEL AS WORLD FIRE PROTECTION IS NOT READY. SPRINKLER MONITORING KHET 4/6/2022 4/6/2022 CANCELED DAVID ALFORD REQUESTED TO CANCEL AS WORLD FIRE PROTECTION IS NOT READY. DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS 101-0000-42421 0 $167.00 $167.00 2/4/22 WEB10630 635210189 62 CREDIT Dalton Ammann EPRS FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS PC 101-0000-42420 0 $250.00 $250.00 2/4/22 WEB10630 635210189 62 CREDIT Dalton Ammann EPRS Total Paid for FIRE FEES: $417.00 $417.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 2/4/22 WEB10630 635210189 62 CREDIT Dalton Ammann EPRS Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 2/4/22 WEB10630 635210189 62 CREDIT Dalton Ammann EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$433.00 $433.00 Printed: Friday, March 03, 2023 2:38:43 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2022-0002 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 1/7/2022 Etrakit Public Registration 1ST SUBMITTAL Extra Space Storage - FA Plans 21-098-00 - La Quinta- Public Storage.pdf 1 DOC 1/7/2022 Etrakit Public Registration 1ST SUBMITTAL Extra Space Storage - Submittal Book/Cutsheets 21-098-00_Submittal book.pdf 1 DOC 2/4/2022 KOHL HETRICK FA2022-0002 - COA AND JOB CARD.pdf FA2022-0002 - COA AND JOB CARD.pdf 1 DOC 2/4/2022 KOHL HETRICK FA2022-0002 - APPROVED PLANS.pdf FA2022-0002 - APPROVED PLANS.pdf 1 DOC 4/7/2022 KOHL HETRICK FA2022-0002 - REC OF COMPLETION.pdf FA2022-0002 - REC OF COMPLETION.pdf 1 BOND INFORMATION SPRINKLER MONITORING KHET 4/7/2022 4/7/2022 APPROVED FIRE FINAL**KHET 4/7/2022 4/7/2022 APPROVED Pending email scanned copy of ROC ROC RECEIVED AND ATTACHED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 1/7/2022 1/24/2022 2/4/2022 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 1/7/2022 1/10/2022 1/7/2022 COMPLETE NEEDS BL FOR CONTRACTOR ACCOUNT TO BE LINKED TO PERMIT. PARENT PROJECTS Printed: Friday, March 03, 2023 2:38:43 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FA2022-0002 AREA OF WORKFATCFACP1" PVC-SCH40(F.B.O.)EXISTINGFACPAT TELCO RMFA0.01COVER SHEETN.T.S.SHEETCOPYRIGHT NOTICETITLE:JOB NUMBER:DATE:DRAWN BY:SCALE:REV REVISION DATEBY01THIS SHEET IS NOT TO SCALE.IF THIS SCALE IS NOT 1".NOTE:EXP. 12-31-2021C10-989173LICENSED ELECTRICALSTATE OF CALIFORNIACONTRACTOR22405 LA PALMA AVEYORBA LINDA, CA 92887TEL: (714) 957-5750 - FAX (714) 957-5749West CoastFire & IntegrationWWW.WESTCOASTFIREINC.COMB.M. BERTINO, LLCBERTINO INDUSTRIAL COMPLEXCLIENT:PLOT DATE: 1/6/2022 2:39:49 PMEXTRA SPACE STORAGE46600 ADAMS STREETLA QUINTA, CA 92253SPRINKLER MONITORINGSYSTEM21-098-0012/07/21JYTBUILDING CONSTRUCTION: II-BBUILDING OCCUPANCY: S1SPRINKLERED: YESNO. OF STORIES: 1AREA OF BUILDING: 26,721 SFPROJECT ADDRESS: 46600 ADAMS STREET LA QUINTA, CA 92253OWNER: EXTRA SPACE STORAGE 1330 CORPORATE DRIVE, SUITE 330, IRVING , TEXAS 75038.MATERIAL LIST AND REQUIREMENTSSCOPE OF WORKPROJECT INFORMATIONDRAWING INDEXGENERAL INSTALLATION NOTESSHEET CONTENTSGENERAL NOTES, MATERIAL LIST, SEQUENCE OF OPERATIONFA0.01FA0.02 BUILDING FLOOR PLAN, CALCULATION $ RISER DIAGRAMSHEETNO.MONITORING INFORMATION01/05/22APPLICABLE CODES & STANDARDSAPPLICABLE CODES & STANDARDS1. WALL-MOUNTED VISUAL SIGNALING APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80 IN. (2.03m) AND NOT GREATERTHAN 96 IN. (2.44m) ABOVE THE FINISHED FLOOR OR AT THE MOUNTING HEIGHT SPECIFIED USING THE PERFORMANCE-BASED ALTERNATIVE OF 18.5.5.6.PER NFPA 72 2016 18.5.5.1. AUDIBLE NOTIFICATION APPLIANCES ALL-MOUNTED SHALL HAVE THEIR TOPS ABOVE THE FINISHED FLOORS AT HEIGHTS OF NOTLESS THAN 90 IN. (2.29m) AND BELOW THE FINISHED CEILINGS AT DISTANCES OF NOT LESS THAN 6 IN. (150mm) PER NFPA 72 2013. MORE THAN TWOVISIBLE NOTIFICATION APPLIANCES OR GROUPS OF SYNCHRONIZED APPLIANCES IN THE SAME ROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEWTHAT FLASH IN SYNCHRONIZATION. PER NFPA 72 2016 18.5.5.4.2.2. SMOKE DETECTORS AND HEAT DETECTOR LOCATIONS ARE BASED ON SMOOTH CEILING WITH MAXIMUM HEIGHT OF 10 FEET UNLESS OTHERWISENOTED.3. NOTIFICATION DEVICES LOCATION IS BASED ON 10 FOOT CEILING HEIGHT AND ARE INSTALLED ACCORDING TO NFPA 72 REQUIREMENTS. CEILINGHEIGHT ABOVE 20' SHALL BE NOTED ON PLANS. ANY DEVICES ON CEILINGS OVER 20 FEET WILL BE DERATED PER NFPA 72.4. STROBES IN SLEEPING AREAS SHALL BE LOCATED WITHIN 16 FEET OF PILLOW AND HAVE MINIMUM INTENSITY OF 110cd. FOR STROBES LOCATED LESSTHAN 24 INCHES FROM CEILING, MINIMUM INTENSITY SHALL BE 177cd.5. THE OPERABLE PART OF A MANUALLY ACTUATED ALARM-INITIATING DEVICE SHALL BE NOT LESS THAN 42" (1.07m) AND NOT MORE THAN 48" (1.22m)FROM THE FINISHED FLOOR. PER 2016 NFPA 72 17.14.5.6. ALL EQUIPMENT SHALL BE U.L. AND C.S.F.M. LISTED.7. ALL WIRING SHALL BE IN ACCORDANCE WITH THE N.E.C. AND AUTHORITIES HAVING JURISDICTION.8. ALL JUNCTION BOXES SHALL BE SIZED IN ACCORDANCE WITH THE N.E.C. AND SHALL HAVE THEIR COVERS PAINTED RED WHERE APPLICABLE.9. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHOOTING, ETC.10. DO NOT DEVIATE FROM WIRE RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (WEST COAST FIRE &INTEGRATION, INC., TEL (714) 957-5750). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC., THAT ARE A RESULT OFCONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR.11. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR-FLOW, NOT CLOSER THAN 3 FEET (900mm) FROM AN AIR SUPPLY DIFFUSER.12. ALL FAN SHUTDOWN FUNCTIONS, DAMPER CLOSURES AND ASSOCIATED MECHANICAL SYSTEM FIRE ALARM INTERFACE SHALL BE BY MECHANICALCONTRACTOR.13. ALL DUCT SMOKE DETECTORS SHALL BE MOUNTED BY THE MECHANICAL OR ELECTRICAL CONTRACTOR. DUCT SMOKE DETECTORS EXPOSED TO THEWEATHER SHALL BE WEATHER PROTECTED BY THE MECHANICAL CONTRACTOR. ALL AIR VELOCITY TESTING SHALL BE PERFORMED BY THE MECHANICALCONTRACTOR.14. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALLREQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION.15. ALL DEVICE BACKBOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTION BOXES AND ASSOCIATED CONDUITS SHALL BE FURNISHED ANDINSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONALINFORMATION. SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED.16. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH SMOKE OR LISTED AEROSOL APPROVED BY THE MANUFACTURER PER NFPA 72, ASACCEPTABLE BY THE A.H.J.17. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE CONTROL PANELTO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE CIRCUITS.18. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES.19. POINT AND COMMON ANNUNCIATION AND T-TAPPING ARE PROHIBITED. (T-TAPPING IS ALLOWABLE ON ADDRESSABLE STYLE B SLC LOOPS).20. PROVIDE 3/4" CONDUIT WITH (2) DEDICATED TELEPHONE LINES WITH RJ-31X PHONE JACKS FROM TELEPHONE BACKBOARD FOR OWNER PROVIDEDCENTRAL STATION MONITORING LOCATED ADJACENT TO CONTROL PANEL.21. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT NOISE LEVELS, BUT NOT LESS THAN 75dBA THROUGHOUTAREA OF ALARM. TESTING SHALL BE ACCOMPLISHED WITH A dB METER. WHERE APPLICABLE, AUDIBLE TONE SHALL BE TEMPORAL PATTERN.22. FIRE ALARM CONTRACTOR SHALL PROVIDE AN IMPEDANCE METER AT THE TIME OF FINAL INSPECTION WHEN REQUIRED BY THE AUTHORITY HAVINGJURISDICTION.23. FIRE ALARM SIGNAL SHALL MEET ANSI S34.1, AUDIBILITY EMERGENCY EVACUATION SIGNAL (TEMPORAL PATTERN)24. ALL CONDUITS ARE 3/4" UNLESS OTHERWISE NOTED.25. ALL DEVICES IN THE SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS.26. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE UL LISTED (UUFX).27. TAMPER-RESISTANT SCREWS OR OTHER APPROVED MECHANICAL MEANS SHALL BE PERMITTED FOR PREVENTING ACCESS TO JUNCTION BOXES ANDDEVICE COVERS INSTALLED OUTSIDE OF BUILDINGS. PER THE 2016 NFPA 72 23.8.5.11.1.28. ELECTRICAL POWER SERVICE SHALL BE ON A DEDICATED BRANCH CIRCUIT(S). THE CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLYPROTECTED (CIRCUIT BREAKERS SHALL BE LOCKED IN THE ON POSITION WITH AN APPROVED MECHANICAL CLIP). CIRCUIT DISCONNECTING MEANS SHALL HAVE A RED MARKING, SHALL BE ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL, AND SHALL BEIDENTIFIED AS "FIRE ALARM CIRCUIT." THE LOCATION OF THE CIRCUIT DISCONNECTING MEANS SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT.[NFPA 72, 2016 10.6.5.2]29. UPON COMPLETION OF ALL INSTALLATION AND TESTING, THE CONTRACTOR SHALL PROVIDE TO THE AUTHORITY HAVING JURISDICTION AND THEBUILDING OWNER A COMPLETED AND SIGNED NFPA 72 CERTIFICATE OF COMPLETION.30. SECTION 17.7.1.11.3 OF THE 2016 EDITION OF NFPA 72 STATES THAT "WHERE DETECTION IS NOT REQUIRED DURING CONSTRUCTION, DETECTORSSHALL NOT BE INSTALLED UNTIL AFTER ALL OTHER CONSTRUCTION TRADES HAVE COMPLETED CLEANUP."31. SECTION NFPA 72 2016 7.7.2.1 STATES. WITH EVERY NEW SYSTEM, A DOCUMENTATION CABINET SHALL BE INSTALLED AT THE SYSTEM CONTROL UNITOR AT ANOTHER APPROVED LOCATION AT THE PROTECTED PREMISES.VICINITY MAPAPPROVAL STAMPSYSTEM TYPE:WEST COAST FIRE & INTEGRATION TO PROVIDE: DESIGN AND INSTALL A SPRINKLER MONITORING SYSTEM ON BUILDING K TO BE CONNECTED ON AN EXISTING FACP AT THE BUILDING.NFPA PATHWAY CLASS AND SURVIVABILITY:PATHWAY CLASSIFICATION - CLASS "B"PATHWAY SURVIVABILITY - LEVEL "0"WEST COAST FIRE AND INTEGRATION SPECIFIC WORK:FURNISH AND INSTALL LOW VOLTAGE WIRE/CABLE, DEVICES, AND CONTROL EQUIPMENT.SYSTEM PROGRAMMING.FINAL INSPECTION.USER TRAINING.PROVIDED, INSTALLED AND/OR POWERED BY OTHERS:DEDICATED 120VAC CIRCUIT(S) AND LOCK ON DEVICES.MOUNTING OF CONTROL CABINETS, DEVICE OUTLET BOXES AND TERMINATION CABINETS.SITE PATHWAYS, UNDERGROUND RACEWAYS AND 120VAC POWER.FIRE STOPPING.QUESTIONS SHOULD BE DIRECTED TO THE FOLLOWING @ (714) 957-5750:SYSTEM SALES REP.: BLANCA VARNEYDESIGN MANAGER: VICTOR BALANCIOINSTALL SUPERINTENDENT: VINCE FRAIREAPPLICADLE CODES AS OF JANUARY 1, 20162019 CALIFORNIA ADMINISTRATIVE CODE, PART 1, TITLE 242019 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 242019 CALIFORNIA ELECTRICAL CODE (CEC), PART 3 TITLE 242019 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 242019 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 242019 CALIFORNIA REFERENCED STANDARDS CODE, PART 12, TITLE 24PARTIAL LIST OF APPLICADLE NFPA STANDARDS:NFPA 13-AUTOMATIC SPRINKLER SYSTEMS (2016 EDITION)NFPA 72-NATIONAL FIRE ALARM CODES (2016 EDITION)EXISTING MONITORING COMPANY TO REMAINMOUNTING HEIGHTBACKBOXMANUFACTURER C.S.F.M. NUMBERMODELSYMBOL DESCRIPTION1QUANTITYTO MATCH EXISTING SEQUENCE OF OPERATIONSYSTEM INPUTSREQUIRED FIRE SAFETY CONTROLNOTIFICATIONCONTROL UNIT ANNUNCIATIONKJIHGFEDCBAFIRE ALARM SYSTEMAC POWER FAILUREFIRE ALARM SYSTEMLOW BATTERYGROUND FAULTWIRE-TO-WIRE SHORT(SLC & NAC)321KJIHGFEDCBALLMANUAL FIRE ALARM BOX8MMOOPPQQNN4BUTTERFLY TAMPER SWITCHSYSTEM OUTPUTSDUCT SMOKE DET.AIR HANDLING UNITSSPRINKLER WATERFLOW SWITCH9PIV TAMPER SWITCHOS& Y TAMPER SWITCH567ELEV. MACHINE ROOMELEV. SMOKE DETECTORELEV. HEAT DETECTORELEV. SHAFT/MACHINE ROOMRR10SSAREA SMOKE DETECTOR131415121116T UT UFIRST FLOOR -MAINELEV. LOBBY SMOKE DET.2ND FLOOR -ALTERNATEELEV. LOBBY SMOKE DET.VVOPEN CIRCUITWWXXSK-6808FIRE ALARM CONTROL PANEL FACPSILENT KNIGHT PROVIDED16"x26.4"x4.65"7165-0559:050266" A.F.F.TO TOPFA0.03 TYPICAL DETAILSQUANTITYEXISTINGNEWTAMPER SWITCH F.B.O. VERIFY INFIELDF.B.O. F.B.O. F.B.O.WATERFLOW F.B.O. VERIFY INFIELDF.B.O. F.B.O. F.B.O.1010P.I.V. TAMPER VERIFY INFIELDF.B.O. F.B.O. F.B.O.1SWITCHSWITCH7300-0559:01324S DEEP BOX W/2 GANG RING FIELDSILENT KNIGHTSD500-AIMFIRE ALARMMONITOR MODULEVERIFY IN21RELAY MODULEFIRE ALARM SILENT KNIGHTSD500-ARM2 GANG RING4S DEEP BOX W/ 7300-0559:0132VERIFY INFIELDDUCT SMOKE DET. F.B.O. VERIFY INFIELDF.B.O. F.B.O. F.B.O.M1010SILENT KNIGHT(ADDRESSABLE - PHOTO)AREA SMOKE DETECTOR SD505-PHOTO3-0 RING4S DEEP BOX W/ CEILING 7272-0559:0178MOUNTED1ROOF UNIT11N/A N/A N/A N/AN/AN/AN/AN/A N/AN/AN/AN/AN/AN/AN/AN/A N/AN/AN/AN/AN/AN/AN/AN/AN/A N/ASITE PLANSITE PLANSCALE: N.T.S.N1211MONITOR BLDG. K SPK SYS. 1.5.22JYT1FA2022-0002SEE RED-LINE COMMENTS79120 CORPORATE CENTER DRIVE 331'-4"10'-8"9'-8"10'-4"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-4"9'-8"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-4"9'-8"10'-8"10'-8"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-8"331'-4"10'-8"9'-8"10'-4"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-4"9'-8"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-4"9'-8"10'-8"81'-4" 10'-8"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-8" 81'-4"FATC RMM110VACS2STO EXISTINGFACPRMM110VACRMM110VACRMM110VACRMM110VACRMM110VACRMM110VACRMM110VACRMM110VACRMM110VAC1-" PVC-SCH40(F.B.O) UCFC1FC2FC3FC5FC6FC7FC9FC8FC4FC10MM2S2S2SSSSSSFATCMMTO EXISTINGFACP1" PVC-SCH40(F.B.O) UCRMM110VAC2SRMM110VACRMM110VACRMM110VACRMM110VACRMM110VACRMM110VACRMM110VACRMM110VACRMM110VACFC1FC2FC3FC5FC6FC7FC9FC8FC4FC10S2S2S2SSSFA0.02BUILDING FLOOR PLANAS NOTEDSHEETC.PYRIGHT NOTICEALL DRAWINGS AND WRITTEN MATERIALSAPPEARING HEREIN C.NSTITUTE THEORIGINAL AND UNPUBLISHED WORK OFWEST C.AST FIRE & INTEGRATION, INC., AND THE SAME MAY NOT BE DUPLICATED,USED OR DISCLOSED WITHOUT THEEXPRESS WRITTEN C.NSENT OFWEST C.AST FIRE & INTEGRATION, INC.TITLE:JOB NUMBER:DATE:DRAWN BY:SCALE:REV REVISION DATE BY 01THIS SHEET IS NOT TO SCALE.IF THIS SCALE IS NOT 1".NOTE:EXP. 12-31-2021C10-989173LICENSED ELECTRICALSTATE OF CALIFORNIAC.NTRACTOR22405 LA PALMA AVE YORBA LINDA, CA 92887 TEL: (714) 957-5750 - FAX (714) 957-5749 West C.ast Fire & Integration WWW.WESTC.ASTFIREINC.C.MB.M. BERTINO, LLCBERTINO INDUSTRIAL C.MPLEXCLIENT:PLOT DATE: 1/6/2022 2:41:42 PMEXTRA SPACE STORAGE 46600 ADAMS STREET LA QUINTA, CA 92253 SPRINKLER MONITORING SYSTEM21-098-0012/22/21JYTFLOOR PLANRISER DIAGRAMBUILDING FLOOR PLANSCALE: 3/32"=1'-0"NF.B.O.FURNISHED BYOTHERSEOLEND OF LINERESISTORMANUAL PULL STATIONFIRE ALARM TERMINAL CABINETFFATCSYMBOL LEGENDRMRELAY MODULEDUCT DET. HOUSING w/SMOKE DETECTOR HEADF.B.O.SPRINKLER BELLCABLE DESIGNATIONSFIRE ALARM CABLE RUNCONDUIT(UNDERGROUND)CABLETAGOPEN WIRINGSSIGNALING LINECKT (SLC)OPEN CABLEFIRE ALARM WIRE LEGENDCONDUIT /UNDERGROUND#16/2 FPLPUC2 #14 THHN/TWNUNDERGROUNDCABLESIGNALING LINE CIRCUIT CALL-OUT LEGENDNOTIFICATION ALARM CIRCUIT CALL-OUT LEGENDPOWER SOURCE #DEVICE #-#N##NAC CIRCUIT #SAMPLE: #N1-1ZONEPTDEVICE ZONE #SAMPLE: #PT###SLC#MMONITOR MODULESTRANDED110VACFIRE ALARM CONTROL PANELFACPEND OF LINE RESISTORHORN / STROBEFIRE ALARM WALLXXcdFLOW SWITCHBUTTERFLY TAMPER SWITCHPIV TAMPER SWITCH1 MONITOR BLDG. K SPK SYS.1.5.22 JYT FA0.03TYPICAL DETAILSN.T.S.SHEETC.PYRIGHT NOTICEALL DRAWINGS AND WRITTEN MATERIALSAPPEARING HEREIN C.NSTITUTE THEORIGINAL AND UNPUBLISHED WORK OFWEST C.AST FIRE & INTEGRATION, INC., AND THE SAME MAY NOT BE DUPLICATED,USED OR DISCLOSED WITHOUT THEEXPRESS WRITTEN C.NSENT OFWEST C.AST FIRE & INTEGRATION, INC.TITLE:JOB NUMBER:DATE:DRAWN BY:SCALE:REV REVISION DATE BY 01THIS SHEET IS NOT TO SCALE.IF THIS SCALE IS NOT 1".NOTE:EXP. 12-31-2021C10-989173LICENSED ELECTRICALSTATE OF CALIFORNIAC.NTRACTOR22405 LA PALMA AVE YORBA LINDA, CA 92887 TEL: (714) 957-5750 - FAX (714) 957-5749 West C.ast Fire & Integration WWW.WESTC.ASTFIREINC.C.MB.M. BERTINO, LLCBERTINO INDUSTRIAL C.MPLEXCLIENT:PLOT DATE: 1/6/2022 2:42:38 PMEXTRA SPACE STORAGE 46600 ADAMS STREET LA QUINTA, CA 92253 SPRINKLER MONITORING SYSTEM21-098-0012/22/21JYTSECTION B-BITS EGRESS FROM THE WALL. CAULK INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED BELOW: F MAX PIPE TFOLLOWING TABLE. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE +WHEN COPPER PIPE IS USED, T RATING IS 0 H.*BEARING THE UL CLASSIFICATION MARKING1/4 to 1/213/16 to 3/846120 to 1-1/21/4 to 1/2Max Pipe or ConduitAnnular SpaceDia In.1 In.0 to 3/163 or 43 or 4*BEARING THE UL CLASSIFICATION MARKINGMINNESOTA MINING & MFG CO - TYPE CP 25WB+.1 or 23 or 41 or 20003/411-1/22Max Pipe or Conduit Diam In.3HrT Rating 1 T Rating F Rating 0+,1 or 2Hr1 or 2HrSTEEL PIPE, NOM 6 IN. DIAMETER (OR SMALLER) STEEL CONDUIT, NOM 4 IN. PIPE OR CONDUIT - NOM 12 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) DIAMETER (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR TYPE L (OR HEAVIER) COPPER TUBING OR NOM 1 IN. DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT. WHEN OF STUD CAVITY WIDTH AND TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. IS PERMITTED IN THE FIRESTOP SYSTEM. PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER(ITEM 3) IS 2 H. STEEL PIPES OR CONDUITS LARGER THAN NOM 4 IN. DIAM MAY ONLY BE USED IN WALLS CONSTRUCTED USING STEEL CHANNEL STUDS. A MAX OF ONE PIPE OR CONDUITCOPPER PIPES OR FLEXIBLE STEEL CONDUIT IS USED, MAX F RATING OF FIRESTOP SYSTEM WALLBOARD, GYPSUM*- NOM 1/2 OR 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE FASTNER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL4 IN. LUMBER SPACED 16 IN. OC WITH NOM 2 BY 4 IN LUMBER END PLATES ANDTHE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE WALL ASSEMBLY- THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM.OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, CROSS BRACES. STEEL STUDS TO BE MINIMUM 3-5/8 IN. WIDE BY 1-3/8 IN DEEPASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOMINAL 2 BYSTUDS- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2H FIRE RATED RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN A MIN 1/4 IN. DIAM BEAD OF CAULK APPLIED TO PERIMETER OF PIPE OR CONDUIT AT FILL ANNULAR SPACE BETWEEN PIPE OR CONDUIT AND GYPSUM WALLBOARD AND WITH FILL, VOID OR CAVITY MATERIAL* - CAULK- CAULK FILL MATERIAL TO COMPLETELY3.OF OPENING IS 13-1/2 IN. 2.CHANNELS SPACED MAX. 24 IN. OC.B.A.1.1BT RATINGS - 0, 1, 2, 3, AND 4 HR (SEE ITEM 3)F RATINGS - 1, 2, 3 AND 4 HR (SEE ITEMS 2 AND 3)SYSTEM NO. WL1001SECTION A-AA1C23A1B31AB32B5T RATINGS--1, 1-1/2 AND 2 HR (SEE ITEM 3)F RATING-- 2 HRL RATING AT 400° F--LESS THAN 1 CFM/sq ftL RATING AT AMBIENT--2 CFM/sq ft (FORMERLY SYSTEM NO. 322)SYSTEM NO. W-L-1016241ATYPICAL THROUGH-PENETRATION FIRESTOP SYSTEMSWALL ASSEMBLY - THE FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNERDESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THEFOLLOWING CONSTRUCTION FEATURES:STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBERSPACED 16 IN. OC WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE BY 1-3/8 IN DEEPCHANNELS SPACED MAX 24 IN. OC.GYPSUM BOARD* - TWO LAYERS OF NOM 5/8 IN. THICK GYPSUM WALLBOARD AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. MAX DIAM OFTHROUGH OPENINGS CUT IN WALLBOARD LAYERS IS 12 IN. MAX DIMENSIONS FOR RECTANGULAR OPENING IS 12 IN. BY 9 IN.FASTENERS - WHEN WOOD STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH CEMENT COATED NAILS AS SPECIFIED IN THEINDIVIDUAL U300-SERIES DESIGN. WHEN STEEL CHANNEL STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH TYPE SSELF-DRILLING, SELF-TAPPING BUGLE-HEAD STEEL SCREWS AS SPECIFIED IN THE INDIVIDUAL U400-SERIES DESIGN.STEEL SLEEVE - NO. 28 GAUGE GALV SHEET STEEL FORMED INTO MAX 12 IN. DIAM OR MAX 12 IN. BY 9 IN. SLEEVE WITH NOM 2 IN. OVERLAP AT SEAM.LENGTH OF SLEEVE TO BE APPROX 1 IN. GREATER THAN OVERALL THICKNESS OF WALL ASSEMBLY, SUCH THAT, WHEN INSTALLED, THE ENDS OF THE SLEEVEWILL PROJECT APPROX 1/2 IN. BEYOND THE SURFACE OF THE WALL ON BOTH SIDES OF THE WALL ASSEMBLY. MAX DIAM OF CIRCULAR THROUGH OPENINGSIN GYPSUM WALLBOARD LAYERS ON EACH SIDE OF WALL ASSEMBLY TO BE 12 IN. MAX DIMENSIONS FOR RECTANGULAR OPENING IS 12 IN. BY 9 IN. SLEEVEINSTALLED BY COILING THE SHEET STEEL TO A DIAM SMALLER THAN THE THROUGH OPENING, INSERTING THE COIL THROUGH THE OPENINGS AND RELEASINGTHE COIL TO LET IT UNCOIL AGAINST THE CIRCULAR CUTOUTS IN THE GYPSUM WALLBOARD LAYERS.STEEL PIPE OR CONDUIT - NOM 3 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE, STEEL CONDUIT OR STEEL ELECTRICAL METALLICTUBING. MULTIPLE PIPES AND/OR CONDUIT PERMITTED IN SLEEVED OPENING PROVIDED A MIN SEPARATION OF 1/4 IN. IS MAINTAINED BETWEEN PIPES ORCONDUITS. PIPES AND/OR CONDUITS TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL ASSEMBLY. THE T RATING OF THE FIRESTOP SYSTEM ISDEPENDENT UPON THE MAX DIAM OF THE PIPES OR CONDUITS, AS TABULATED BELOW:PACKING MATERIAL - MIN 1 IN. THICKNESS OF RIGID GLASS FIBER INSULATION OR MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO STEEL SLEEVE ONBOTH SIDES OF WALL ASSEMBLY AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED MIN 5/8 IN. FROM SURFACE OF WALL ON BOTH SIDES OFWALL ASSEMBLY.FILL,VOID OR CAVITY MATERIALS* - CAULK - APPLIED TO FILL THE STEEL SLEEVE TO A MIN DEPTH OF1 IN. ON BOTH SIDES OF WALL ASSEMBLY. A NOM 1/4 IN. DIAM CONTINUOUS BEAD OF CAULK SHALLBE APPLIED AROUND THE CIRCUMFERENCE OF THE STEEL SLEEVE AT ITS EGRESS FROM THE GYPSUMWALLBOARD LAYERS ON BOTH SIDES OF THE WALL ASSEMBLY. (GYPSUM) (GYPSUM)1.2.3.4.5.A.B.C.MOUNTING HEIGHT GUIDELINESSTROBEHORN-STROBESTATIONPULL96" MAX.84" MIN.72" MAX.60" MIN.CEILING LINEFINISHEDFLOOR LINEGUTTERSUGGESTEDDETECTOR6" MIN.90" AFF MIN.HORNANNUNCIATORSMOKE4" MIN.60" AFFREQUIRED80" AFF.(SEE NOTE 1)to96" AFF.REQUIRED(SEE NOTE 3)48" AFF. RECOMMENDED3-1/2' to 4-1/2' AFF. REQUIRED (SEE NOTE 2)ENTER#369TROUBLEALARMACSUPERVISORY0*258147SILENCERESETSILENCEDKNIGHTSILENTFIRE ALARM CONTROL COMMUNICATORModel SK-5208KNIGHTSILENTPULLDOWNMODEL 5235ENTERFIRE ALARM ANNUNCIATORACK#369TROUBLEALARMACSUPERVISORY0*258147SILENCERESETSILENCEDNOT TO SCALE& BUTTERFLY TAMPER SWITCH INSTALLATION DETAILTYPICAL WATERFLOW SWITCHINITIATING DEVICEMODEL 7628 (4.7k)UL LISTED EOLRTYPICALDATA OUT (+)DATA OUT (-)DATA IN (-)DATA IN (+).55mA.55mAACTIVATEDOPERATING VOLTAGE 24 VDC (MAX 33 VDC)STANDBYUSES ONE MODULE ADDRESSCOVER PLATE (SUPPLIED)SD500-AIM MODULE (SUPPLIED)(SUPPLIED BY ELEC. CONTRACTOR)4"SQ. X 1-1/2" DEEP BACKBOXMOUNTING SCREWS(SUPPLIED BY ELEC. CONTRACTOR)MOUNTING SCREWS (SUPPLIED)87654321ADDRESSDIP SWITCHLEDSTATUSSD500-AIMFOR SURFACE OR FLUSH MOUNTSILENT KNIGHT SD500-AIM - ADDRESSABLE INPUT MODULE-+STATUSLEDDIP SWITCHADDRESSSD500-AIM87654321ONSLC A BDATA IN (-)DATA IN (+).55mA.55mAACTIVATEDOPERATING VOLTAGE 24 VDC (MAX 33 VDC)STANDBYUSES ONE MODULE ADDRESSCOVER PLATE (SUPPLIED)SD500-ARM MODULE (SUPPLIED)(SUPPLIED BY ELEC. CONTRACTOR)4"SQ. X 1-1/2" DEEP BACKBOXMOUNTING SCREWS(SUPPLIED BY ELEC. CONTRACTOR)MOUNTING SCREWS (SUPPLIED)87654321ADDRESSDIP SWITCHLEDSTATUSSD500-ARMFOR SURFACE OR FLUSH MOUNTSILENT KNIGHT SD500-ARM - ADDRESSABLE RELAY MODULESTATUSLEDDIP SWITCHADDRESSSD500-ARM87654321ONC1 NO1 SLC +- NC1N02C2NC2 DATA OUT (-)DATA OUT (+)RATED AT 2A @ 30VDCTWO SETS OF FORM C CONTACTSOR .6A @ 120VACSILENT KNIGHT 6808 FIRE ALARM PANEL (TYPICAL)BLACKRED -+-+DEVICETYPICALTO NEXTDEVICEINITIATIONA (TYP.)-+-+TYPICALINITIATIONDEVICESIGNILING LINE CIRCUIT(ADDRESSABLE DEVICES)SK-6808SILENTKNIGHTTO 120VACDEDICATEDCIRCUIT(FBO)BLACKWHITE (NEU)GREEN (GRD)TROUBLERELAYSCIRCUIT "N4"NOTIFCATION APPLIANCEUSBNAC4NAC3NAC2NAC1 CIRCUIT "N3"NOTIFCATION APPLIANCECIRCUIT "N2"NOTIFCATION APPLIANCECIRCUIT "N1"NOTIFCATION APPLIANCEFORM CRELAYS-+-+TYPICAL SBUS DEVICEPOWER24VDCSYSTEMCOMM.A (TYP.)(ANNUNCIATOR OR 5496 POWER SUPPLY)POWER24VDCSYSTEMCOMM.TO NEXTSBUS DEVICE(MAX. 12 DEVICES)SBUS +A B-(SEE FACP CALCULATION FOR AMP.)12VDC, BATTERY(SEE FACP CALCULATION FOR AMP.)12VDC, BATTERY1 MONITOR BLDG. K SPK SYS.1.5.22 JYT SALES ● DESIGN ● INSTALLATION ● SERVICE 22405 La Palma Avenue Phone (714) 957-5750 Lic.# C10-989173 Yorba Linda, CA 92887 Fax (714) 957-5749 ACO# 7407 www.westcoastfireinc.com Extra Space Storage 46600 Adams Street La Quinta, CA 92253 Job# 21-098-00 Sprinkler Monitoring System Product Data • Capable of providing up to 198 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single- point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models • Convenient field-upgradeable GJSNXBSF •#VJMUJOEVBMQBUI 1054BOE*1 DPNNVOJDBUJPOTXJUI PQUJPOBMDFMMVMBS NPEFMTBWBJMBCMFGPS SFMJBCMFCBDLVQ SFQPSUJOH • 6860 annunciator with a 4 x 40 large display •'PVSVTFS QSPHSBNNBCMFCVUUPOT NJOJNJ[FUJNFTQFOU FYFDVUJOHDPNQMFYPS SPVUJOFUBTLT • Built-in USB interface for convenient and quick programming • Programmable date setting for automatic and convenient Daylight Saving Time changes •+VNQ4UBSUkBVUP QSPHSBNNJOHSFEVDFT JOTUBMMBUJPOUJNF • 125 software zones and 125 output groups for fl exible design options 6808 "EESFTTBCMF'JSF"MBSN$POUSPM1BOFM 5IFJTBOBEESFTTBCMFGJSFBMBSNDPOUSPMQBOFM '"$1 UIBUJTB EJSFDUSFQMBDFNFOUGPSUIF'"$15IFDBOCFDPOGJHVSFEUP BDIJFWFBQPJOUDBQBDJUZPGQPJOUT*UIBTPOFCVJMUJOTJHOBMJOHMJOF DJSDVJU 4-$ XIJDIDBOTVQQPSU4ZTUFN4FOTPSk 4, TFOTPSTBOE 4,NPEVMFTPS)PDIJLJk 4% EFWJDFTQFSMPPQ "DPNNPODPNNVOJDBUJPOTBOEBOOVODJBUJPOMJOLBMMPXTVQUP QBOFMTUPCFDPOOFDUFEWJBDPQQFSPSfiCFSPQUJDDBCMF"EFTJHOBUFE QBOFMJTDPOfiHVSFEBTUIFDPNNVOJDBUPSGPSBMMQBOFMTJOUIFMJOLGPS DPOWFOJFOUTJOHMFQPJOUDPNNVOJDBUJPOT*UBMTPIBTBCVJMUJO EVBM MJOF1054BOE*1DPNNVOJDBUPSXJUIBEEJUJPOBMDFMMVMBSPQUJPOT BWBJMBCMF 5IFTZTUFNDBOCFFOIBODFECZBEEJOHNPEVMFTTVDIBTUIF SFNPUFBOOVODJBUPSXIJDIBMTPIBTGPVSQSPHSBNNBCMFGVODUJPO CVUUPOTUPIFMQBVUPNBUFUBTLTBOESFEVDFUJNFTQFOUBUUIFQBOFM 48*'5kXJSFMFTTDPNQBUJCJMJUZQSPWJEFTPQUJPOTGPSXJSFMFTTEFUFDUJPO UISPVHIB$MBTT"NFTIOFUXPSL*UJTJEFBMGPSIBSEUPXJSFMPDBUJPOT CVJMEJOHTXIFSFOFXXJSJOHJTOPUBMMPXFE PSUPQSPWJEFBOFBTZJOTUBMM fi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• General Alarm (Red)'MBTIFTJGJO BMBSNTPMJEXIFOBMBSNJTTJMFODFE • Supervisory (Yellow):'MBTIFTJGB TVQFSWJTPSZDPOEJUJPOFYJTUTTPMJE XIFOTVQFSWJTPSZJTTJMFODFE •System Troubles (Yellow)'MBTIFT JGBUSPVCMFDPOEJUJPOFYJTUT TPMJEXIFOUSPVCMFJTTJMFODFE •System Silenced (Yellow) 0OXIFOBOBMBSN USPVCMFPS TVQFSWJTPSZDPOEJUJPOIBTCFFO TJMFODFECVUOPUZFUDMFBSFE • System Power (Green): 'MBTIFT GPS"$GBJMVSFTPMJEXIFO QPXFSTZTUFNTBSFOPSNBM USER INTERFACE 5IFCVJMUJOYBOOVODJBUPS XJUIDIBSBDUFS-$%EJTQMBZ BOEMBSHFFBTZUPVTFUBDUJMF UPVDIQBEDBOCFVTFEGPSTZTUFN PQFSBUJPO QSPHSBNNJOHBOE NBJOUFOBODF*UIBs fiWF-&%TGPS BMBSN TVQFSWJTPSZ TZTUFNUSPVCMF TZTUFNTJMFODFEBOETZTUFNQPXFS 4ZTUFNPQFSBUJPOTJODMVEFTJMFODJOH BMBSNTBOEUSPVCMFT SFTFUUJOHBMBSNT BOEUIFEJTQMBZPGBMBSNUSPVCMFTBOE NFNPSZ5IFTZTUFNTOPOWPMBUJMF FWFOUIJTUPSZCVGGFSTUPSFT FWFOUTGPSWJFXJOHGSPNUIFCVJMU JOPSSFNPUFBOOVODJBUPS4ZTUFN PQFSBUJPOTDBOCFJOJUJBUFEXJUIB NFDIBOJDBl fiSFfiHIUFSTLFZPSB WBMJEUPEJHJUPQFSBUPSTDPEF •UL-JTUFE4 • CSFM • FDNY$0" •FMBQQSPWFE SIGNAL LINE CIRCUIT (SLC) 5IF4-$MPPQTVQQPSUTNVMUJQMF EFWJDFUZQFT NBJOUFOBODFBMFSUT BOEB CVJMUJOTFOTPSUFTUUPDPNQMZXJUI/'1" DBMJCSBUJPOUFTUJOHSFRVJSFNFOUT INDICATOR LIGHTS PROGRAMMING 5IFTZTUFNPGGFSTTFWFSBMPQUJPOT UPTJNQMJGZBOETQFFEVQQSPHSBNNJOH +VNQ4UBSUkBVUPQSPHSBNNJOH NJOJNJ[FTQSPHSBNNJOHSFRVJSFEUPTUBSU BOFXTZTUFN5IFCVJMUJOLFZQBE PSUIF PSSFNPUF BOOVODJBUPSTHJWFZPVPOTJUFBDDFTTUP DVSSFOUTZTUFNQSPHSBNNJOH 1SPHSBNNJOHDBOBMTPCFBDDPNQMJTIFE VTJOHUIF8JOEPXTkCBTFE)POFZXFMM 'JSF4PGUXBSF4VJUF )'44 QSPHSBN SOFTWARE TOOLS SKST:4JMFOU,OJHIU4FMFDUJPO5PPM QSPWJEFTUIFJOTUBMMFSPSEFTJHOBSDIJUFDU XJUIB8JOEPXTkTPGUXBSFTZTUFN DPOGJHVSBUJPOUPPMUPDSFBUFBEFUBJMFE#JMM PG.BUFSJBM #0. BOECBUUFSZ DBMDVMBUJPOT HFSS:)POFZXFMM'JSF4PGUXBSF4VJUF QSPWJEFTDPNNVOJDBUJPOBOEQBOFM QSPHSBNNJOH EFUFDUPSTUBUVT FWFOU IJTUPSZBOEBEEJUJPOBMEBUB3FRVJSFTB 1$SVOOJOH.JDSPTPGUk8JOEPXTk ADDITIONAL INFORMATION 5XJTUFEVOTIJFMEFEQBJS XJSFJTSFDPNNFOEFE 5IFBMTPIBTQSFTFUOPUJGJDBUJPO DBEFODFQBUUFSOT JODMVEJOH"/4* "(&/$:-*45*/(4"/%"11307"-4 /1'" /'1" /'1" /'1" /'1"$FOUSBMTUBUJPOSFNPUF 4JHOBMJOH-PDBM1SPUFDUJWF4JHOBMJOH 4ZTUFNT"VYJMJBSZ1SPUFDUFE1SFNJTFT 6OJU8BUFS%FMVHFSFMFBTJOHTFSWJDF 4VJUBCMFGPSBVUPNBUJD NBOVBM XBUFSGMPX TQSJOLMFSTVQFSWJTPSZ %"$5 OPODPEFE TJHOBMJOHTFSWJDFT ORDERING INFORMATION "EESFTTBCMF'JSF"MBSN $POUSPM1BOFM 3FEDBCJOFU COMPATIBLE ANNUNCIATORS 6860:Y-$%SFNPUe fiSF BOOVODJBUPS MJOFTBOEVQUP DIBSBDUFST QFSTZTUFNGPVS QSPHSBNNBCMFCVUUPOT 5860:Y-$%SFNPUe fiSF BOOVODJBUPSJTHSBZ3JTSFE 6855:Y-$%SFNPUe fiSF BOOVODJBUPS 5865-3 or 5865-4:-&%BOOVODJBUPST DBOEJTQMBZVQUP-&%T SFEBOE ZFMMPX 5IFIBTLFZTXJUDIFT GPSTJMFODFBOESFTFU BOEBTZTUFN USPVCMF-&% 5880:-&%*0NPEVMFIBT QSPHSBNNBCMF-&%PVUQVUTBOEFJHIU TVQFSWJTFEESZDPOUBDUJOQVUTXIJDIBSF VTFGVMGPSDVTUPNBQQMJDBUJPOT:PVDBO VTFVQUPFJHIUNPEVMFTPOPOF DPOUSPMQBOFMGPSNBYJNVm flFYJCJMJUZ *UTDPNQBDUTJ[FBMMPXTNPVOUJOHJOTJEF UIFBOOVODJBUPS PSJOBOBDDFTTPSZ DBCJOFU 6808 COMPATIBLE DEVICES AND ACCESSORIES 4FFUIFEBUBTIFFUTMJTUFECFMPXGPSB DPNQMFUFMJTUJOHPGUIF4, 4%PS48*'5 EFWJDFT 4,%FWJDFT%BUB4IFFU 4%%FWJDFT%BUB4IFFU 48*'5 XJSFMFTTEFWJDFT 'PSBDPNQMFUFBOEDVSSFOUMJTUJOHPG DPNQBUJCMFEFWJDFTBOEBDDFTTPSJFT WJTJU www.silentknight.com Important::PVDBOOPUNJY4,BOE4% EFWJDFTJOUIFTBNFGJSFBMBSNTZTUFN 1BHFPGŘ# 4,$0.1"5*#-&"%%3&44"#-& DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperBture SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) 4,)&"58'JYFEUIFSNBMEFUFDUPS m' XIJUF SK-HEAT-ROR: Fixed rate of rise detector (135°F) 4,)&"53038'JYFESBUFPGSJTF EFUFDUPS m' XIJUF SK-HEAT-HT: Fixed high temperature thermal detector (190°F) 4,)&"5)58'JYFEIJHIUFNQFSBUVSF UIFSNBMEFUFDUPS m' XIJUF SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector 4,1)05081IPUPFMFDUSJDTNPLF EFUFDUPS XIJUF SK-PHOTO-T: Photoelectric smoke detector with thermal (135°F fixed temperBture) 4,1)050581IPUPFMFDUSJDTNPLF EFUFDUPSXJUIUIFSNBM m'GJYFE UFNQFSBUVSF XIJUF SK-PHOTOR: Photoelectric detector with remote test capability 4,1)050381IPUPFMFDUSJDEFUFDUPS XJUISFNPUFUFTUDBQBCJMJUZ XIJUF SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module # *7 CBTFGPS4,84FSJFT #-1NPVOUJOHCBTF # #- *7 8)*5& GMBOHFMFTTCBTF #'MBOHFMFTTNPVOUJOHCBTF #4 *7 8) *OUFMMJHFOUTPVOEFSCBTF #4*OUFMMJHFOUTPVOEFSCBTF #4-' *7 8) -PX'SFRVFODZ JOUFMMJHFOUTPVOEFSCBTF #4-'-PXGSFRVFODZJOUFMMJHFOU TPVOEFSCBTF #3# *7 8) 3FMBZCBTF #3#3FMBZCBTF ##* *7 8) *TPMBUPSCBTF B224BI: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-6IB: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for the SD505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector. SD505-DUCTR: Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 135°F–150°F (0°C–37°C). SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: “R” indicates red; “W” denotes white. For a complete listing of Silent Knight AV devices go to XXXTJMFOULOJHIUDPN. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. 84,8(*8JSFMFTT(BUFXBZ 84,1)0508JSFMFTT1IPUPFMFDUSJDTNPLF EFUFDUPS WSK-PHOTO-T:8JSFMFTT.VMUJDSJUFSJB QIPUPFMFDUSJDTNPLFEFUFDUPSXJUIUIFSNBM EFUFDUJPO m'GJYFEUFNQFSBUVSF BOE #8CBTF WSK-HEAT:8JSFMFTT)FBU m'GJYFE UFNQFSBUVSF BOE#8CBTF WSK-HEAT-ROR:8JSFMFTTIFBU 303 m'GJYFEUFNQFSBUVSF BOE#8 CBTF WSK-MONITOR:8JSFMFTTNPOJUPSNPEVMF WSK-RELAY:8JSFMFTTSFMBZNPEVMF W-USB:48*'55PPMT64#USBOTDFJWFSVTFE GPSDPNNVOJDBUJPOXJUI48*'5EFWJDFT SBUS ACCESSORIES 5496:"BNQOPUJGJDBUJPOQPXFSFYQBOEFS XJUIGPVSQPXFSMJNJUFEOPUJGJDBUJPO BQQMJBODFDJSDVJUPVUQVUT 5883:3FMBZ*OUFSGBDF1SPWJEFT'PSN$ SFMBZT 5824:4FSJBM1BSBMMFM1SJOUFS*OUFSGBDF .PEVMFGPSQSJOUFSDPOOFDUJPO 5895XL:1PXFS4VQQMZXJUITJY'MFYQVUƇ DJSDVJUT BOEUXP'PSN$SFMBZT.BYQFS TZTUFN 5815RMK:3FNPUFNPVOUJOHLJU %JNFOTJPOTŠ8YŠ)YŠ% COMMUNICATION OPTIONS CELL-CAB-SK:$FMMVMBSDPNNVOJDBUPS NFUBMFODMPTVSFXJUIMPDLLFZ CELL-MOD:$FMMVMBSDPNNVOJDBUPS QMBTUJD FODMPTVSF 4PMFQBUI QPXFSFECZQBOFM IPGSM-4G:%VBMQBUIGJSFBMBSN DPNNVOJDBUPS DFMMVMBSBOEPS*1 QSJNBSZPS CBDLVQ TFMFDUBCMF SK-IP-2:3FNPUFSFQPSUJOHWJBUIF*OUFSOFU 3FRVJSFTB7JTPS"MBSNkSFDFJWFSBUUIFDFOUSBM TUBUJPO MISC. ACCESSORIES SK-NIC:/FUXPSL*OUFSGBDF$BSE1SPWJEFTB DPNNPODPNNVOJDBUJPOTMJOLGPSUIF SK-NIC-KIT:*OTUBMMBUJPO"DDFTTPSZ,JU SK-FML:'JCFS0QUJD.VMUJ.PEF USBOTNJUUFSBOESFDFJWFS SK-FSL:'JCFS0QUJD4JOHMF.PEF RBB:3FNPUFCBUUFSZCPYBDDFTTPSZDBCJOFU GPSCBUUFSJFTUIBUBSFUPPMBSHFUo fiUJOUIF '"$1DBCJOFU%JNFOTJPOTŠ8YŠ)Y Š% NN8YNN)YNN% SK-SCK:4FJTNJD$PNQMJBODF,JUVTFEUP TFDVSFMZGBTUFOCBUUFSJFTUPUIe fiSFQBOFM 1BHFPGŘ# 'MFYQVUk )POFZXFMMk +VNQ4UBSUk 4JMFOU,OJHIUk 48*'5k BOE4ZTUFN 4FOTPSkBSFSFHJTUFSFE USBEFNBSLTPG)POFZXFMM *OUFSOBUJPOBM*OD )PDIJLJkJTBSFHJTUFSFE USBEFNBSLPG)PDIJLJ $PSQPSBUJPO.JDSPTPGUk BOE8JOEPXTkBSF SFHJTUFSFEUSBEFNBSLTPG .JDSPTPGU$PSQPSBUJPO 5IJTEPDVNFOUJTOPU JOUFOEFEUPCFVTFEGPS JOTUBMMBUJPOQVSQPTFT8F USZUPLFFQPVSQSPEVDU JOGPSNBUJPOVQUP EBUFBOEBDDVSBUF8F DBOOPUDPWFSBMMTQFDJGJD BQQMJDBUJPOTPSBOUJDJQBUF BMMSFRVJSFNFOUT"MM TQFDJGJDBUJPOTBSFTVCKFDU UPDIBOHFXJUIPVUOPUJDF 'PS5FDIOJDBM4VQQPSU DBMM 5FDIOJDBM4QFDJGJDBUJPOT PHYSICAL Overall Dimensions:Š8YŠ)YŠ% Shipping Weight:MCT Color:3FE ENVIRONMENTAL Operating Temperature:m'UPm' m$UP m$ Humidity:UPSFMBUJWFIVNJEJUZ OPO DPOEFOTJOH ELECTRICAL 6808 Primary AC:7"$!)[ "5PUBM "DDFTTPSZ-PBE"!7%$QPXFSMJNJUFE Standby Current:N" Alarm Current:N" Battery Charging Capacity:UP") Battery Size:")UP")NBYBMMPXFEJODPOUSPM QBOFMDBCJOFU-BSHFSDBQBDJUZCBUUFSJFTDBOCF IPVTFEJO3##BDDFTTPSZDBCJOFU Honeywell Silent Knight $MJOUPOWJMMF3PBE /PSUIGPSE $5 ]#] g)POFZXFMM*OUFSOBUJPOBM*OD NOTIFICATION APPLIANCE CIRCUITS (NACs) Four programmable circuits which can be programmed individually as: NACs:"!7%$QFSDJSDVJU QPXFSMJNJUFE XJUIBNBYJNVNDVSSFOUPG" Auxiliary Power Circuits:"!7%$QFSDJSDVJU QPXFSMJNJUFE 4VQQPSUT$MBTT# 4UZMF BOE$MBTT" 4UZMFPS DPOfiHVSBUJPOGPSUIF4-$ WIRING:4FFUIFQSPEVDUNBOVBMGPSXJSJOHEFUBJMT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7165-0559:0502 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE:SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Silent Knight Model 6808, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). *The CELL-MOD and CELL-CAB-SK have the option to be configured by a compatible control unit for the following pathways: Cellular only without a backup path, primary Cellular communication path, or secondary Cellular communication path. Model 6808 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network Inerface Card SK-NIC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16"WX10"HX6"D) SK-SCK Seismic Complaince Kit RATING:Primary Operating Power Supply: 120VAC, 60HZ, 3.25A Secondary Operating Power Supply: 24VDC, 750mA, 55Ah INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances *Rev 10-02-19 gt July 01, 2021Date Issued:Listing Expires June 30, 2022 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Listing No. Page 2 of 2 7165-0559:0502 and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and indicating devices. Refer to listee’s Installation Instruction Manual for details. *Rev 10-02-19 gt July 01, 2021Date Issued:Listing Expires June 30, 2022 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Model SD505-PHOTOAnalog / AddressablePhotoelectric Type SmokeDetectorThe SD505-PHOTO is particularlysuited to detecting dense smoketypical of fires involving materialssuch as soft furnishings, plastic,foam or other similar materialswhich tend to smolder and producelarge visible particles.The detector features automaticcompensation for contaminationand a simple detector calibrationtest procedure that can be run fromthe panel or remotely (using theWindowsTMbased downloadingsoftware).OperationThe SD505-PHOTO units made upof an LED light source and a siliconphoto diode receiving element. In anormal standby condition, thereceiving element receives no lightfrom the pulsing light source. In theevent or fire, smoke enters thedetector and light is reflected fromthe smoke particles to the receivingelement.The light received is converted intoan electronic signal. Under normalconditions, the status LED blinks approximately every 15 seconds,indicating that the head iscommunicating with the loop. TheLED lights continuously during thealarm period.Features•Low profile, 2 inches, includingbase•Simple and reliable addressingwithout mechanical switches•Automatic compensation forsensor contamination•Built-in fire test feature•Simple detector calibrationtesting through the control panelor remotely through aWindowsTMbased computersoftware.•Vandal-resistance lockingfeatures•Field cleanable•UL listed, meets NFPA 72 Ch 7requirements•CSFM approved•MEA approved•FM ApprovedSpecificationsOperating Voltage:24-41 VDCCurrent Consumption:Standby:.55 mAAlarm:.55 mA Ambient Temperature:32ºF to120ºF (0ºC to 49ºC)Mounting: 4” Square, 4” OCT,Single gang mud ringRelative Humidity:85% non-condensingAir Velocity: 0 - 300 FPMCompatible Bases:SD505-6AB (Sold Separately)SD505-6IBSD505-6RBSD505-6SB P/N 350225 Rev G© 2015 Honeywell International Inc. Addressable Photoelectric Smoke Detector IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings wheresmoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-PHOTOphotoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious secondsare wasted in determining location of an alarm.The SD505-PHOTO compensates automatically for contamination in the environment. And detector testing issimple—even from a remote site. Like other IntelliKnight detector models, the SD505-PHOTO offers a low profilefor pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, ModelSD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you’vecome to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection,and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Detect smoldering fires quickly and get help fast with IntelliKnight®photoelectric smoke detectors. SD505-PHOTO Smoke Detector INTELLIKNIGHT ACCESSORY INTELLIKNIGHT ACCESSORYModel SD505-PHOTOAddressable PhotoelectricSmoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detectorSilent Knight SD505-PHOTO. The combination detector head, and twist-lock base, shall be UL®listedcompatible with Silent Knight’s IntelliKnight fire control panels.The base shall permit direct interchange with Silent Knight SD505-HEAT Heat Detector. Base shall be theappropriate twist-lock base SD505-6AB.The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, theflashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch.The calibration of the detector shall be capable of being selected and measured by the control panel without theneed for external test apparatus.The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. Thelocking feature shall be field selectable as required.The SD505-PHOTO shall automatically perform a functional test of the detector. The test method shall simulateeffects of products of combustion in the chamber to ensure testing of detector circuits. Model SD505-6AB Detector Base(front view)Model SD505-PHOTO Detector Head(front view) This document is not intended to be used for installation purposes. We try to keep ourproduct information up-to-date and accurate. We cannot cover all specific applications oranticipate all requirements. All specifications are subject to change without notice. For moreinformation, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone:(800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7272-0559:0178 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE:SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Model SD505-PHOTO analog, photoelectric smoke detector for use with Model SD505-6AB base. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:17.0 - 39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical/temperature rating and UL label. APPROVAL: Listed as an analog photoelectric smoke detector for use with listee’s separately listed compatible fire alarm control units Hochiki Models FireNet Plus (CSFM No. 7165-0410:0180) and FireNet 4127 (CSFM No. 7165-0410:0159) . Refer to listee’s Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF:7272-0410:0204 10-22-15 gt July 01, 2021Date Issued:Listing Expires June 30, 2022 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. DescriptionThe SD500-AIM and SD500-MIM areaddressable input modules for use withthe Intelliknight fire alarm controlpanels (FACPs). The SD500-AIMaddressable input module mounts to a4"-square box. The SD500-MIM miniinput module fits inside a single gangbox. Both input modules are designedto be used with pull stations, water flowswitches, and other applicationsrequiring dry contact alarm initiationdevices. These modules are supervised, singleinput contact monitors. Using an EOLresistor, they monitor for alarm contactclosures and for open circuit wiringfault conditions. If a fault occurs in thewiring, the module alerts the FACP.Each addressable input module isprogrammed with a unique signal linecircuit (SLC) loop address.Features•Single contact monitor•SD500-AIM supports Class A (StyleD) or Class B (Style B) contactmonitor wiring•SD500-MIM support for Class B(Style B) contact monitor wiring•Attractive ivory cover plate with theSD500-AIM•Small and lightweight size allows forflexible mounting options with theSD500-MIM •DIP switch programmable for fastinstallation•Up to 2500 ft wiring distance fromeither input module to contact•Use up to 14 gauge wire•UL listedElectrical SpecificationsStandby Current: 0.55 mAAlarm Current: 23 mA max for onedevice; 46 mA max for two devices;0.55 mA for each additional deviceLine Resistance: 50ž maxMechanical SpecificationsSD500-AIM Physical DescriptionDimensions:4.9" W x 4.9" H x 1" D(12.4 W x 12.4 H x 2.5 D cm)Weight: 3.6 oz (120.1 g)Color: Ivory cover plateSD500-MIM Physical DescriptionDimensions:1.5" W x 2.5" H x 0.7" D(3.8 W x 6.4 H x 1.8 D cm)Weight: 1.6 oz (45.4 g)EnvironmentalOperating Temperature:32ºF – 120ºF (0ºC – 49ºC)Humidity: 10% – 93% non-condensing ApprovalsNFPA 71 & NFPA 72UL 864 CSFM 7300-0559: 132MEA 429-92-E Vol. IXFM Approved for use with the 5820XL SD500-AIM & SD500-MIMAddressable Input Modules The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight IntelliKnight firealarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, waterflow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fitsinside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister,they monitor for alarm contact closures and for open circuit wiring fault conditions.The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easyinstallation and stable operation—a flexible solution for all your fire protection needs.For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. IntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. INTELLIKNIGHT ACCESSORY INTELLIKNIGHT ACCESSORY MADE IN AMERICAFORM# 350231 Rev. F © 2013 Honeywell International Inc This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight12 Clintonville Road, Northford, CT 06472-1610.Phone: (800) 328-0103 Fax: (763) 493-6475 For Technical Support, Please call 800-446-6444..www.silentknight.com Compatible FACPs5820XL5820XL-EVS58085700 Ordering InformationSD500-AIM Input ModuleAddressable input module with ivorycover plate.SD500-MIM Input ModuleAddressable mini input module. SD500-AIM & SD500-MIMAddressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent KnightSD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnightFACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plasticcover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIMaddressable input module must provide a monitor LED that is visible from outside the cover plate CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7300-0559:0132 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Model SD500-ARM Relay Module, *SD500-ANM addressable NAC Module and SD 500-AIM, SD500-MIM Addressable Input Modules. Models SD500-ARM provides inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MIM provide additional input circuits*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:SD500-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee’s separately listed compatible fire alarm control units. Refer to listee’s Installation Instruction Manual for details. *Rev. 06-10-19 gt July 01, 2021Date Issued:Listing Expires June 30, 2022 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Compatible Control Panels•IFP-2000• IFP-1000•IFP-100• IFP-50 P/N 350219 Rev DCopyright © 2010 Honeywell International Inc. SD500-ARMAddressable Relay Module GeneralThe SD500-ARM is an addressable device that adds twoForm C contacts to the Farenhyt addressable system. Thecontacts are rated at 2.0 amps @ 30 VDC or .6 amp @120 VAC. The SD500-ARM allows you to control a widevariety of normally open and normally closed applications,including elevator recall, door closing, fan operation, andauxiliary notification. And, because the relay module isaddressable, these applications can be located at anypoint in the signaling line circuit. Features• Two sets of Form C contacts. (Double pull/DoubleThrow relays)•Contacts are rated at 2A @ 30 VDC or .6A @ 120 VAC.• Up to 127 relays can be used on each SLC loop.•Relay programming is completely flexible—can bemapped to zone conditions.•Polling LED visible through cover plate.• UL listed, complies with NFPA 72.•CSFM approved• MEA approved• FM approved SpecificationsContact Rating: Form C2A @ 30 VDC or.6A @ 120 VACStandby Current: .55 mAAlarm Current: .55 mAOperating Temperature: 32ºF to 120ºF (0ºC to 49ºC)Dimensions:4-7/8”H x 4-7/8”W x 1”DMounting:4-square MEA429-92-E,Vol 9 Intelligent Device SD500-ARM Agency Listings Model SD500-ARM Dimensions SD500-ARM Wiring Made in the U.S.A. This document is not intended to be used for installation purposes. We try to keepour product information up-to-date and accurate. We cannot cover all specificapplications or anticipate all requirements. All specifications are subject to changewithout notice. For more information, contact Silent Knight 12 Clintonville Road,Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118.www.farenhyt.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.7300-0559:0132 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Model SD500-ARM Relay Module, *SD500-ANM addressable NAC Module and SD 500-AIM, SD500-MIM Addressable Input Modules. Models SD500-ARM provides inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MIM provide additional input circuits*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:SD500-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee’s separately listed compatible fire alarm control units. Refer to listee’s Installation Instruction Manual for details. *Rev. 06-10-19 gt July 01, 2021Date Issued:Listing Expires June 30, 2022 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org February 4, 2022 West Coast Fire Inc 22405 La Palma Ave Yorba Linda, CA 92887 Re: Monitoring Fire Alarm System Plan Review – EXTRA SPACE STORAGE FA2022-0002 / 79120 CORPORATE CENTER DRIVE, LA QUINTA, CA 92253 The fire alarm system plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Function Test / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79120 CORPORATE CENTER DRIVE PERMIT#: FA2022-0002 DATE ISSUED: 2/4/2022 DESCRIPTION: SPK MONITORING ALARM SYSTEM CONTRACTOR: WEST COAST FIRE INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.