FA2022-0013ADDITIONAL SITES
CHRONOLOGY
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT Benjamin Robinson 5981 Republic St.Riverside CA 92504 (951)352-7589 brobinson@troyalarm.
com
BILL TO Benjamin Robinson 5981 Republic St.Riverside CA 92504 (951)352-7589 brobinson@troyalarm.
com
CONTRACTOR TROY ALARM INC 5981 REPUBLIC ST RIVERSIDE CA 92504 (951)352-7589 BROBINSON@TROYAL
ARM.COM
OWNER Panera Bread`3630 S Gyer Rd St. Louis MO 63127 (951)352-7589 brobinson@troyalarm.
com
CONDITIONS
Description: New Fire Sprinkler Monitoring System
Type: FIRE ALARM (WEB)Subtype: COMMERCIAL -
SPRINKLER MONITORING
Status: FINALED Applied: 11/7/2022 EPRS
Parcel No: 643080051 Site Address: 78902 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 12/7/2022 KHET
Subdivision: PM 25865 Block: Lot: 12 Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/11/2023 KHET
Valuation: $4,200.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details:
FINANCIAL INFORMATION
Printed: Wednesday, September 27, 2023 11:41:18 AM 1 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FA2022-0013
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
ROUGH-WIRE INSPECTION KHET 3/9/2023 3/9/2023 APPROVED SEE NOTES
AS-BUILT PLANS REQUIRED PRIOR TO FINAL
INSPECTION.
*COA LETTER WAS DISCUSSED FOR
FUNCTION AND DUCT DETECTOR TESTING.
FUNCTION TEST KHET 5/9/2023 5/10/2023 APPROVED Based functions passed
DUCT
DETECTORS/VELOCITY KHET 5/9/2023 5/10/2023 DISAPPROVE
D SEE NOTES
Contractor shall coordinate to have
magnahelic/magnometer available for
testing.
FIRE FINAL**KHET 5/9/2023 5/10/2023 DISAPPROVE
D SEE NOTES
In addition to not having the duct detector
testing completed, contractor shall provide
NFPA 72 Record of Completion and have
stored in the Document Cabinet.
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
FIRE SPRINKLER
SYSTEMS SUPERVISION
AND ALARMS
101-0000-42421 0 $167.00 $167.00 3/2/23 WEB14498 825054479 CREDIT 792133 ECON
FIRE SPRINKLER
SYSTEMS SUPERVISION
AND ALARMS PC
101-0000-42420 0 $250.00 $250.00 3/2/23 WEB14498 825054479 CREDIT 792133 ECON
Total Paid for FIRE FEES: $417.00 $417.00
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 3/2/23 WEB14498 825054479 CREDIT 792133 ECON
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $8.00 $8.00 3/2/23 WEB14498 825054479 CREDIT 792133 ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $8.00 $8.00
TOTALS:$436.00 $436.00
Printed: Wednesday, September 27, 2023 11:41:18 AM 2 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FA2022-0013
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 11/7/2022 Etrakit Public
Registration
1ST SUBMITTAL CUT
SHEETS
Panera Bread La Quinta
Cut Sheets.pdf 1
DOC 11/7/2022 Etrakit Public
Registration 1ST SUBMITTAL PLAN Panera Bread La Quinta
Plans.pdf 1
DOC 12/7/2022 KOHL HETRICK FA2022-0013 -
APPROVED PLANS.pdf
FA2022-0013 -
APPROVED PLANS.pdf 1
DOC 12/7/2022 KOHL HETRICK FA2022-0013 - COA AND
JOB CARD.pdf
FA2022-0013 - COA AND
JOB CARD.pdf 1
DOC 3/9/2023 KOHL HETRICK FA2022-0013 - 3-9-2023
- INSP NOTES.pdf
FA2022-0013 - 3-9-2023
- INSP NOTES.pdf 1
DOC 5/4/2023 KOHL HETRICK FA2022-0013 - AS-BUILT
SUBMITTAL.pdf
FA2022-0013 - AS-BUILT
SUBMITTAL.pdf 1
DOC 5/4/2023 KOHL HETRICK FA2022-0013 - AS-
BUILTS APPROVED.pdf
FA2022-0013 - AS-
BUILTS APPROVED.pdf 1
DOC 5/11/2023 KOHL HETRICK FA2023-0013 NFPA72
Rec of Comp.pdf
FA2023-0013 NFPA72
Rec of Comp.pdf 1
BOND INFORMATION
DUCT
DETECTORS/VELOCITY KHET 5/11/2023 5/11/2023 APPROVED
FIRE FINAL**KHET 5/11/2023 5/11/2023 APPROVED
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS REMARKS NOTES
1ST FIRE (2 WK)KOHL
HETRICK
11/7/2022 11/21/2022 12/7/2022 APPROVED SEE ATTACHMENTS
1ST PERMIT TECH (1
DAY)
AARON
HICKSON
11/7/2022 11/8/2022 11/7/2022 COMPLETE
PARENT PROJECTS
Printed: Wednesday, September 27, 2023 11:41:18 AM 3 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FA2022-0013
FA2022-0013 AS-BUILT
REVISION:MANUAL PULLGROUNDOPENAREA SMOKEWATERFLOWTAMPERSCOPE OF WORK:PROVIDE AND INSTALL A FIRE SPRINKLER MONITORING SYSTEM TO CONSIST OF: A FIRE ALARM CONTROL PANEL, REMOTE ANNUNCIATOR,INDICATING DEVICE, AND INITIATING DEVICES.WIRE TO BE PROVIDED TO COMPLETE THE ABOVE. BOXES TO BE FURNISHED BY OTHERS.PROJECT INFO:OCCUPANCY CLASSIFICATION: A-2CONSTRUCTION TYPE: VBFULLY SPRINKLERED: YESSQUARE FOOTAGE: 4,177 TOTAL SQ. FT.NUMBER OF FLOORS: 1OCCUPANCY LOAD: 125 TOTALSIGNAL TOMONITORINGSTATIONLOCALLYANNUN-CIATEDTROUBLEONPANELSUPER-VISORYALARMXXXXXXXXXXXXXXXUL CENTRAL STATION:ADVANCED PROTECTION INDUSTRIES INC., DBANATIONAL MONITORING CENTER26800 LAGUNA HILLS DRIVE SUITE 250ALISO VIEJO, CA 926561-800-662-1711S-8126-1AC POWERRISER WIRING DIAGRAMPROJECT: PANERA BREAD78902 HWY 111LA QUINTA, CA 92253951-352-75895981 REPUBLIC STRIVERSIDE, CA 92504TROYALARMC.L. 792133 C-10DRAWN BY: B.J.R.DATE: 10-26-22PAGE: 1 OF 1FIREALARMFIRE ALARM FLOOR PLANSCALE: 1/8" = 1'-0"NORTHFIRE ALARMCONTROL PANELPFAAGENERAL NOTES:1. OCCUPANCY CLASSIFICATION: A-22. THE INSTALLATION SHALL BE IN ACCORDANCE WITH THE FOLLOWING: 2016 NFPA 72, 2019 CEC, 2019 CFC, 2019 CBC3. THE SYSTEM INSTALLATION SHALL HAVE INSTRUCTIONS POSTED AT THE CONTROL PANEL WITH A PLACARD AT LEAST 20 SQ. IN., ORNEAR THE CONTROL UNIT/ANNUNCIATOR, AND INDICATING THE PRIME CONTRACTOR.4. EXPOSED WIRING NOT IN PROTECTIVE CONDUIT SHALL BE PROTECTED IN ACCORDANCE WITH THE NEC AND ADEQUATELY SUPPORTEDTO PROTECT AGAINST PHYSICAL INJURY.5. POWER LIMITED WIRING SHALL BE SEPARATED FROM NON-POWER LIMITED WIRING, LIGHT, POWER, AND CLASS 1 CIRCUITS, AMINIMUM OF 1/4" WHEN IN THE SAME ENCLOSURE.6. PRIMARY POWER SHALL COME FROM A 20 AMP DEDICATED CIRCUIT BREAKER.7. ALL WIRE SHALL BE THWN, FPL, OR FPLR SOLID UNTINNED COPPER.8. INITIATING CIRCUITS ARE TO BE WIRED "CLASS B", INDICATING CIRCUITS ARE TO BE WIRED "CLASS B", AND SIGNALING LINE CIRCUITSARE TO BE WIRED "CLASS B".9. SYSTEM TO BE BATTERY BACKED UP FOR 24 HOURSPEOL Z-2EOL Z-3EOL Z-9EOL Z-10EOL Z-501APPLICABLE CODES:2019 CALIFORNIA BUILDING CODE - PART 2, TITLE 24, CCR2019 CALIFORNIA ELECTRICAL CODE - PART 3, TITLE 24, CCR2019 CALIFORNIA MECHANICAL CODE - PART 4, TITLE 24 CCR2019 CALIFORNIA PLUMBING CODE - PART 5, TITLE 24, CCRAPPLICABLE STANDARDS:NFPA STANDARDS EDITION72 ALARM SYSTEMS 2016SYSTEM DESIGNER:GREG HILLMAN5981 REPUBLIC STREETRIVERSIDE, CA 92504951-352-7589SYMBOL LEGENDQUANTITY SYMBOL DESCRIPTION AND MOUNTING DETAILS CSFMEOL N-1SEQUENCE OF OPERATIONSITE PLANSCALE: N.T.S.NORTHNTSBACKFLOW PREVENTER ASSEMBLYNTSFIRE ALARM PANEL DETAILNTSRISER DETAILPOST INDICATING VALVENTSPOST INDICATING VALVE1/2" LIQUID TIGHT FLEX CONDUITWEATHER PROOF TRANSITION COUPLING(FROM UNDERGROUND TO FLEX CONDUIT)BURIED SCH-80 CONDUIT18"MIN.18"MIN.WIRE LISTED FORUNDERGROUND/OUTDOOR USE WILLBE INSTALLEDWEATHER-PROOF TAMPERSWITCH; PROVIDED, INSTALLEDAND ADJUSTED BY FIRESPRINKLER CONTRACTOR1/2" LIQUIDTIGHT FLEX CONDUIT(SECURE TO PIPE AT 12"INTERVALS)WEATHER-PROOF JUNCTION BOXFROM UNDERGROUND TO FLEXCONDUITRIGID METAL CONDUIT REQUIREDDEPTH TO BURYBURIED 3/4" SCH-80 CONDUITTRANSITION FROMRIGID TO PVC CONDUITCOMPLY WITH LOCALINSTALLATION REQUIREMENTS IFMORE RESTRICTIVETYPICALBACKFLOWPREVENTIONDETAIL4" SQUARE BOXMINIMUM 1-1/2" DEEPEDGE OFJUNCTION BOX TOBE FLUSH WITHCEILING TILESURFACEADJUSTABLE BARHANGER FORCEILING MOUNTEDJUNCTION BOXES(COMPATIBLEWITH SUSPENDEDCEILING SYSTEM)ADJUSTABLE BARHANGER FOR CEILINGMOUNTED JUNCTIONBOXES (COMPATIBLEWITH SUSPENDEDCEILING SYSTEM)TO FACPLOCATEJUNCTION BOX INCENTER OF TILET-BAR SUSPENDEDCEILING SYSTEM(TYPICAL)TO NEXT DEVICECEILING MOUNTED SMOKEDETECTOR/INDICATING DEVICE DETAILWATERFLOWSWITCHCONDUITTOROOFSPACEMANUAL PULL &DEVICE ELEVATIONSTROBE /HORN STROBEFIRE ALARMANNUNCIATORMANUAL PULLSTATION48"TO CENTER60"TO TOP81"TO CENTER120V-20A DEDICATED CIRCUIT FROMPOWER DISTRIBUTION PANEL (LABELCIRCUIT BREAKER "FIRE ALARM"FIRE ANNUNCIATORFIRE ALARM PANELCELL12VDCBATTERYSECTION A-AAAC US321B1AFIRESTOP DETAIL1. WALL ASSEMBLY -- THE 1 OR 2 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BECONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALLAND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWINGCONSTRUCTION FEATURES:A. STUDS -- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TOCONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. STEEL STUDS TO BE MIN 2-1/2 IN. WIDE AND SPACED MAX 24IN. OC. WHEN STEEL STUDS ARE USED AND THE DIAM OF OPENING EXCEEDS THE WIDTH OF STUD CAVITY, THEOPENING SHALL BE FRAMED ON ALL SIDES USING LENGTHS OF STEEL STUD INSTALLED BETWEEN THE VERTICALSTUDS AND SCREW-ATTACHED TO THE STEEL STUDS AT EACH END. THE FRAMED OPENING IN THE WALL SHALL BE 4TO 6 IN. WIDER AND 4 TO 6 IN. HIGHER THAN THE DIAM OF THE PENETRATING ITEM SUCH THAT, WHEN THEPENETRATING ITEM IS INSTALLED IN THE OPENING, A 2 TO 3 IN. CLEARANCE IS PRESENT BETWEEN THEPENETRATING ITEM AND THE FRAMING ON ALL FOUR SIDES.B. GYPSUM BOARD* -- 5/8 IN. THICK, 4 FT WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM BOARD TYPE,THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THEINDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 32-1/4IN. FOR STEEL STUD WALLS. MAX DIAM OF OPENING IS 14-1/2 IN. FOR WOOD STUD WALLS. THE F RATING OF THEFIRESTOP SYSTEM IS EQUAL TO THE FIRE RATING OF THE WALL ASSEMBLY.2. THROUGH-PENETRANTS -- ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLYOR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE SHALL BE MIN 0 IN. TO MAX 2-1/4 IN. PIPEMAY BE INSTALLED WITH CONTINUOUS POINT CONTACT. PIPE, CONDUIT OR TUBING MAY BE INSTALLED AT ANANGLE NOT GREATER THAN 45 DEGREES FROM PERPENDICULAR. PIPE, CONDUIT OR TUBING TO BE RIGIDLYSUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITSOR TUBING MAY BE USED:A. STEEL PIPE -- NOM 30 IN DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.B. IRON PIPE -- NOM 30 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.C. CONDUIT -- NOM 4 IN DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR 6 IN. DIAM STEEL CONDUIT.D. COPPER TUBING -- NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING.E. COPPER PIPE -- NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.3. FILL, VOID OR CAVITY MATERIAL* -- SEALANT -- MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THEANNULUS, FLUSH WITH BOTH SURFACES OF WALL. AT THE POINT OR CONTINUOUS CONTACT LOCATIONS BETWEENPIPE AND WALL, A MIN 1/2 IN. DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE PIPE WALL INTERFACE ONBOTH SURFACES OF WALL . HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS-ONE SEALANT *BEARING THEUL CLASSIFICATION MARKSystem No. W-L-1054F Ratings - 1 and 2 Hr (See Items 1 and 3)T Rating - 0 HrL Rating At Ambient - Less Than 1 CFM/Sq FtL Rating At 400 F - 4 CFM/Sq FtREPRODUCED BY HILTI, INC. COURTESY OFUNDERWRITERS LABORATORIES, INC.DECEMBER 4, 2002DISPATCHFIREDEPT.NOTIFYRESPONSIBLEPARTYX XX XX XPRIMARY POWER DETAILS 120V-20A DEDICATEDCIRCUIT FROM DISTRIBUTION PANEL (LABELCIRCUIT BREAKER "FIRE ALARM"ANNUNCIATORDMP XR150POINT TO POINT WIRING DIAGRAM26312 V.D.C.BATTERYPIVSWITCHC NOZ-2DDCSWITCHC NOSMOKEDETECTORC NOZ-9WATERFLOWC NOZ-10MANUALPULLC NOZ-501MONITORMODULEWIRE LEGEND:A - 18/4 FPLB - #14 THWNXXXXN-1C NOZ-3WEATHERPROOF SUPERVISORY TAMPER SWITCH(PROVIDED BY FIRE SPRINKLER CONTRACTOREXCEPTION TO 5' LIMIT RULE)PPEOL01FIRE ALARM CONTROL PANELFACPFAACELLMOUNT AT 66" A.F.F. TO TOP OF PANELDMP XR150L-R7165-1157:01357165-1157:01357165-1157:01357272-1653:01527150-1157:01127135-1653:05037770-0328:00017770-0328:00107770-0328:0010DMP 630FDMP 263LTE-VSYSTEM SENSOR 2W-BDMP 850SSYSTEM SENSOR P2RLPOTTER VSR-FPOTTER PCVS-1POTTER OSYSU-1REMOTE ANNUNCIATORCELLULAR COMMUNICATORSMOKE DETECTORMANUAL PULL STATIONHORN STROBEWATERFLOW SWITCHVALVE TAMPER SWITCHVALVE TAMPER SWITCHEOL RESISTORINSTALL AT LAST DEVICE ON ALARM CIRCUIT WHERE INDICATEDMOUNT ON DDC WHERE INDICATED, FURNISHED BY OTHERSMOUNT ON PIV WHERE INDICATED, FURNISHED BY OTHERSMOUNT ON SPRINKLER RISER WHERE INDICATED, FURNISHED BY OTHERSMOUNT AT 81" A.F.F. IN DOUBLE 4S BOX W/SINGLE P RING WHERE INDICATEDMOUNT AT 48" A.F.F. TO CENTER OF DEVICE IN 4S BOX W/SINGLE P RINGMOUNT ON CEILING WHERE INDICATED IN 4S BOX W/SINGLE P RINGMOUNT INSIDE FACPMOUNT AT 60" A.F.F. IN BOX SUPPLIED BY FIRE ALARM CONTRACTOR01010101010101027165-1157:0135DMP 711SMONITOR MODULEMOUNT IN DOUBLE GANG BOX WHERE INDICATED05XDOCNANADOCUMENT CABINETMOUNT ADJACENT TO FACP01.BAKER'SSTORAGED3D4.60D3.60D2.36F4.48F1.48 F2.48DB.36F5.48F3.36F3.36F3.36Dx.24DB.36....DB.36....DUCT SMOKE DETECTOR DETAILNTSFIRE ALARMJUNCTION BOX(MOUNTED ONBOTTOM OF JOISTTO FACP (RUN WIREON TOP OF BOTTOMOF CHORD)1/2" METAL FLEXDUCT SMOKEDETECTORINSTALLED BYMECHANICALCONTRACTOR RE: 5.0A-1 5.0 B-1COMPLY WITH LOCALINSTALLATION REQUIREMENTS IFMORE RESTRICTIVEDINING AREAMENS WOMENSORDERPREPERATIONSTORAGESTORAGECOOLERFACPCELLPPEOL Z-2EOL Z-3EOL Z-9EOL Z-501EOL Z-10EOL N-1FAAAX3/4" PVC W/2 - B3/4" PVC W/4 - BDOCA4ADUCTDET.RELAYC NODUCTDET.C NODUCTDET.C NODUCTDET.C NORRRRMOUNT ON SUPPLY SIDE OF AC DUCT WHERE INDICATED SMOKE DUCT DETECTOR043242-1653:0207SYSTEM SENSOR D4120RRRR2A2AA7300-1004:0101APOLLO AMERICA MR101/CRELAYMOUNT IN DOUBLE GANG BOX WHERE INDICATED04RRELAYRELAYRELAYDUCT DETECTORXXHVACSHUTDOWNX XXXXXXXXXXMONITORMODULEMONITORMODULEMONITORMODULEMONITORMODULEEOL Z-502EOL Z-503EOL Z-504EOL Z-505EOL Z-502EOL Z-503EOL Z-504EOL Z-505EOL Z-505EOL Z-504EOL Z-503EOL Z-502
OFFICE OF THE FIRE MARSHAL – LA QUINTA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
December 7, 2022
Troy Alarm
5981 Republic Street
Riverside, CA 92504
Re: Monitoring Fire Alarm System Plan Review – PANERA BREAD
FA2022-0013 / 78902 HIGHWAY 111, LA QUINTA, CA 92253
The fire alarm system plans you submitted for the above referenced project have been reviewed by
Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the
following conditions.
1. For Central Station monitoring service, provide written documentation, at the time of acceptance
testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72.
2. The Office of the Fire Marshal staff shall witness the following inspections/tests:
a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection.
b) Duct Detector / Velocity Testing – Requires provision of magnometer/magnahelic gauge.
c) Function Test / Final Acceptance Testing and Certification
3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the
approved plans and specifications as required.
4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and
equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section
7.7.2
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
RIVERSIDE COUNTY FIRE PROTECTION PLANNING
RECORD OF INSPECTIONS / PERMIT CARD
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS: 78902 HIGHWAY 111 PERMIT#: FA2022-0013 DATE
ISSUED: 12/7/2022
DESCRIPTION: PANERA BREAD CONTRACTOR: TROY ALARM
HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS
Thrust block pre-pour Door fan test
UG rough piping Abort test
UG hydro Mechanical shutdown
Flush Detector test
Final E F Deluge/pre-action
SPRINKLER U.G. Final E F
Thrust block pre-pour UST/AST TANK
UG rough piping Installation
UG hydro Removal
Flush Emergency shut off
Final E F Primary piping
FIRE SPRINKLER Secondary piping
Weld inspection Dispensers & shear valves
Overhead rough piping Final E F
Overhead hydro MISC. INSPECTIONS
UG flush / OK to connect Spray booths
Main drain/inspectors’ test Hood/duct extinguishing
High pile storage High pile rack storage
In-rack sprinklers H.P. vents/access/corridors
Hose racks Tract access/hydrant verification
Final E F Access & Address verification
HOOD EXTINGUISHING OTHER CONST. PERMIT
Detection system
Function test
Gas/electrical shut-off
Nozzle model/placement
Fire alarm connection
Final E F
SPRAY BOOTHS FIRE CODE PERMIT(S)
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final E F
FIRE ALARM KNOX SYSTEM
Rough-wire inspection Building Knox box
Function test Gate access Knox box/padlock
Duct detectors/velocity BUILDING INSPECTIONS
24 hr. battery test T/I final
Sprinkler monitoring Shell final
Final E F Final for occupancy
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE**
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspections. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.