Loading...
FA2022-0014ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT MONTY SORENSEN 41651 CORPORATE WAY #6 PALM DESERT CA 92260 (760)776-8811 COMTRON01@AOL.CO M BILL TO comtron 41651 Corporate Way #6 Palm Desert Ca 92260 (760)776-8811 Comtron01@aol.com CONTRACTOR COMTRON SYSTEMS PO BOX 13470 PALM DESERT CA 92255 (760)776-8811 JOHN@COMTRON1.CO M OWNER OLD TOWN LA QUINTA LLC 78010 MAIN ST NO 201 LA QUINTA CA 92253 (760)776-8811 CONDITIONS Description: RD RNNR Restaurant TI Type: FIRE ALARM (WEB)Subtype: COMMERCIAL - FIRE ALARM SYSTEM Status: FINALED Applied: 12/21/2022 EPRS Parcel No: 770121012 Site Address: 78065 MAIN ST STE 200 LA QUINTA,CA 92253 Approved: 1/4/2023 KHET Subdivision: PM 30850 Block: Lot: 6 Issued: 1/5/2023 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/17/2023 LRO Valuation: $3,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Add notification to existinf FACP FINANCIAL INFORMATION Printed: Wednesday, September 27, 2023 11:46:29 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2022-0014 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH-WIRE INSPECTION KHET 1/9/2023 1/9/2023 APPROVED AS-BUILT REQD PRIOR TO FINAL DUCT DETECTORS/VELOCITY KHET 3/15/2023 3/15/2023 APPROVED FUNCTION TEST KHET 3/15/2023 3/15/2023 APPROVED SEE NOTES Portion of wire noted on plans needs to be secured and strapped up. Both FACP and Power Supply circuits need to be RED labeled and provide with lockout tamper. Revised Plans and calcs are still required prior to tomorrows inspection and Final. DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE ALARM SYSTEMS 101-0000-42421 0 $525.00 $525.00 1/5/23 WEB13969 782718359 CREDIT MONTY SORENSEN EPRS FIRE ALARM SYSTEMS PC 101-0000-42420 0 $613.00 $613.00 1/5/23 WEB13969 782718359 CREDIT MONTY SORENSEN EPRS FIRE FAILED OR ADDITIONAL FIELD INSPECTIONS (EXCESSIVE) EACH 101-0000-42421 0 $175.00 $175.00 3/16/23 WEB14654 833719177 CREDIT MONTY SORENSEN EPRS Total Paid for FIRE FEES: $1,313.00 $1,313.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 1/5/23 WEB13969 782718359 CREDIT MONTY SORENSEN EPRS Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $8.00 $8.00 1/5/23 WEB13969 782718359 CREDIT MONTY SORENSEN EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $8.00 $8.00 TOTALS:$1,332.00 $1,332.00 Printed: Wednesday, September 27, 2023 11:46:29 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2022-0014 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/21/2022 Etrakit Public Registration FIRE DEVICE DATA SHEET OLD TOWN LA QUINTA data sheet .pdf 1 BOND INFORMATION 24 HR. BATTERY TEST LRO 3/16/2023 3/16/2023 APPROVED Function test and Battery ring out passed. FIRE FINAL**LRO 3/16/2023 3/16/2023 DISAPPROVE D See Notes B4 scheduling Comtron, From today’s Fire Alarm final, we have the 24-hour battery test passed. We will need to re-schedule the fire final due to missing items listed below: 1. NAC Power Supply supplemental Record of Completion form filled out at time of re- inspection. 2. Full size reviewed and approved As-Builts installed in document cabinet. 3. All troubles need to be cleared from panel and showing NORMAL. *Re inspection Fees may apply. FIRE FINAL**LRO 3/17/2023 3/17/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 12/21/2022 1/4/2023 1/4/2023 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY)JACK LIMA 12/21/2022 12/22/2022 12/21/2022 PENDING DOCUMENTS PENDING PLAN SET AND APPLICANT HAS BEEN NOTIFIED. PARENT PROJECTS Printed: Wednesday, September 27, 2023 11:46:29 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2022-0014 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/21/2022 Etrakit Public Registration FIRE NOTIFICATION FOR RESTAURANT TENANT IMPROVEMENT STE #201 OLD TOWN _12-19- 22TI.pdf 1 DOC 1/4/2023 KOHL HETRICK FA2022-0014 - APPROVED PLANS.pdf FA2022-0014 - APPROVED PLANS.pdf 1 DOC 1/4/2023 KOHL HETRICK FA2022-0014 - COA AND JOB CARD.pdf FA2022-0014 - COA AND JOB CARD.pdf 1 DOC 1/9/2023 KOHL HETRICK FA2022-0014 - 1-9-2023 - Insp Notes.pdf FA2022-0014 - 1-9-2023 - Insp Notes.pdf 1 DOC 3/15/2023 KOHL HETRICK FA2022-0014 - 3-15- 2023 - Insp Notes.pdf FA2022-0014 - 3-15- 2023 - Insp Notes.pdf 1 DOC 3/16/2023 KOHL HETRICK FA2022-0014 - AS- BUILTS APPROVED.pdf FA2022-0014 - AS- BUILTS APPROVED.pdf 1 Printed: Wednesday, September 27, 2023 11:46:29 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2022-0014 1147 SFOUTDOOR PATIO DINING104336 SFPRIVATE DINING1031940 SFMAIN DINING AREA1021021 SFBAR AREA101218 SFWAITING AREA100EXISTINGSTAIRS TOREMAIN ASIS2'-0"ANSULEOLRE2695757515151515309515157575757527POW SUP EOLRE604CEILING @9'-0"EOLRE6052829SMK2650' 18 GA. 2 COND. FPLR UL WIRE. ZONE #27 MMF-301A PWR SUPPLY AC FAIL50' 18 GA. 2 COND. FPLR UL WIRE. ZONE #28 MMF-301A PWR SUPPLY LOW BAT255' 14 GA. 2 COND. FPLR UL WIRE. ZONE #604 NAC CIRCUITDESCRIPTIONWIRESYMBOL28604605170' 14 GA. 2 COND. FPLR UL WIRE. ZONE #605 NAC CIRCUIT50' 18 GA. 2 COND. FPLR UL WIRE. ZONE #29 SMOKE DETECTOR2950' 18 GA. 2 COND. FPLR UL WIRE. ZONE #26 KITCHEN ANSUL27DESCRIPTIONSYMBOLBACK BOX MOUNTING HIEGHT MANUFACTUER MODEL CSFMQTYFACPFAAEOLRE 39200 FIRELITE ALARM CONTROL PANELSUPERVISED REMOTE COMMAND UNIT4S DEEP TOP OF BOX BELOW 60" A.F.F ANN-807120.0075-0211END OF THE LINE RESISTORN/A N/A N/A N/AN/AFIRE ALARM SYMBOL LEGEND4S DEEPTOP OF BOX BELOW 60" A.F.FFIRELITE9200ULLADA 7165.0075:0217PWR SUPXXHORN/STROBE (CANDELA SHOWN)SA-WBBBOTTOM OF BOX 80" A.F.FOR CEILINGXXSTROBE (CANDELA SHOWN) 9P2RL-PC2RLSYSTEM SENSOR7125-1653:0517SR OR SCR*K = WPSYSTEM SENSORSA-WBBBOTTOM OF BOX 80" A.F.FOR CEILING7125-1653:0504802ULADA POWER SUPPLY4S DEEP TOP OF BOX BELOW 60" A.F.F AL802ULADA7315-1335:0107EXISTINGANSULMMF-301AANSUL ALARMN/A4S DEEP7300-0075:0185 1smk 1FIRELITEALTRONIX 6EXISTINGFIRELITEFIRELITE SMOKE DETECTOR4S DEEPCEILINGFIRELITESD3657272-0075:0502EXISTINGFIRE ALARM NOTES1. The applicable codes and standards are the 2019 California FireCode (CFC),2019 California Building Code (CBC) and NFPA 72.2. The system shall be pre-tested prior to inspection to determine thatthe system is properly installed and functions in accordance with the approved plans and the manufacturer'sinstallation and maintenance manual. (NFPA 72 7.5.2)3. Upon completion, a copy of "as built" drawings and written operationand maintenance instructions shall be provided to theowner/occupant.4. A 24-hour emergency response phone number shall be permanentlyposted adjacent to the control panel.5. The installing contractor shall provide an Record of Completion to theinspector and to the business owner following completion of alarmtesting as witnessed by. (CFC 907.7.2)6. Automatic fire sprinkler water flow alarms, supervisory initiatingdevices, and their circuits, shall be designed and installed so thatthey cannot be readily tampered with, opened, or removed withoutinitiating a signal.7. Through penetration fire stopping for all fire walls, floor/ceilings, andassemblies shall have an "F" or "T" rating per the CBC andstandards. Installation of fire stopping shall comply with approvedmethods.8. The circuit disconnect breaker providing power to the fire alarm unitshall only be accessible to authorized personnel, and shall beidentified as "FIRE ALARM CIRCUIT".9. All fire control units shall be interconnected with all other fire alarmcontrol units located within the facility. (NFPA 72: 23.8.2.1. 23.8.2.2and 23.8.2.3)10. All audible alarm notification signals shall be a three pulse temporalpattern. (CFC 907.5.2.1.3)11. Audible alarm should sound level shall be the minimum specified byCFC 907.5.2.1.12. When more than two visual notification appliances are located withinthe same room or area, they shall be synchronized. (NFPA 72:18.5.5.4.2)13. All fire sprinkler systems shall be monitored except those noted inCFC 903.414. Where a building fire alarm or monitoring system is installed,automatic fire- extinguishing systems shall be monitored by thebuilding fire alarm or monitoring system in accordance with NFPA72. (CFC 904.3.5)SEQUENCE OF OPERATIONSPULL STATION SMOKE DET. HVAC DUCT DET. POWER FAILURE SYSTEM TROUBLE WATERFLOW SW.VALVE TAMPER SW.ANNUNCIATE AT PANEL YES YES YES YES YES YES YESANNUNCIATE AT REMOTE ANNUNCIATOR YES YES YES YES YES YES YESSOUND AUDIBLE DEVICES YES YES NO NO NO YES NOACTIVATE CENTRAL STATION CONNECTION-ALARM YES YES NO NO NO YES NOACTIVATE CENTRAL STATION CONNECTION-SUPERVISORY NO NO YES NO NO NO YESACTIVATE CENTRAL STATION CONNECTION-SYSTEM TROUBLE NO NO NO YES YES NO NOSOUND EXTERIOR WATERFLOW ALARM BELL NO NO NO NO NO YES NO2 WIRE NON SHIELDEDTYPICAL WIRING TO SD MON-2ONSCOPE OF WORKResturant TI has an existing Fire System thatincludes (3) existing appliances and Ansul cook hoodfire alarm monitors.The Installation includes theaddition of (9) strobe only appliances and (6)Horn/Strobes tied into a new NAC power supply withone smoke Detector above the Power Supply.(+)(-)EOLRFROMFACP(+)(-)EOLRFROMFACPSPRENCLER FLOW SWITCH SPRENCLER FLOW SWITCH(+)(-)EOLRFROMFACPFOST INDICATOREOLRALARM HORNSEOLRMANUAL PULL STATIONS(+)(-)FROMFACP(+)(-)FROMFACPEOLRSTROBE LIGHTS(+)(-)FROMFACPEOLRSMOKE/HEAT DETECTORS(+)(-)FROMFACPWIRE DESIGNATION CHARTNAC #604 VOLTAGE DROP24-HOUR BATTERY CALCULATIONPOWER SUPPLYNAC #605 VOLTAGE DROPSYSTEM INSTALLATIONBYCOMTRON SYSTEMS, INC.41-651 CORPORATE WAYSUITE 6PALM DESERT, CA 92260TELE: (760) 776-8811STATE CONTRACTORSC-10 LIC#:530025PROJECT TITLESCALE:DATE:DRAWING NUMBER: 1 of 1PROJECT NUMBER:CHECKED BY: APREVISIONSRESTURAUNT T.I.78-065 MAIN ST.OLD TOWN SUITE 201LA QUINTA, CA. 9225312/19/22 SITE MAP:SCALE: 1/8":1'FIRE ALARM PLANSYSTEM DESIGN / INSTALLER COMPANY - COMTRON SYSTEMSADDRESS - P.O. BOX 13470 PALM DESERT, CA 92255-3470TELE: 760-776-8811C-10 LIC#:530025APPLICABLE DATAOCCUPANCY: A-2OCCUPANT LOAD: 1247CONSTRUCTION TYPE: TYPE VB,BUILDING SQ. FOOTAGE:TOTAL BUILDING = 37,978 S.F.FIRE SPRINKLER COVERAGE THROUGHOUTUL CENTRAL STATION SERVICEBY TRI-STAR MONITORING1255 GRAPHITE DRIVECORONA, CA. 92881DESIGNED BY: MONTY SORENSENW116715RESTAURANT FIRE SYSTEM T.I.MONITOR-MMF-301AFA2022-0014 - AS-BUILTS 1147 SFOUTDOOR PATIO DINING104336 SFPRIVATE DINING1031940 SFMAIN DINING AREA1021021 SFBAR AREA101218 SFWAITING AREA100EXISTINGSTAIRS TOREMAIN ASIS2'-0"ANSULANSULEOLREEOLRE2625ANSULEOLRE2475757515151515157515157575757527POW SUPEOLRE604CEILING @9'-0"EOLRE605ANN28SMK2750' 18 GA. 2 COND. FPLR UL WIRE. ZONE #27 MMF-301A PWR SUPPLY AC FAIL50' 18 GA. 4 COND. FPLR UL WIRE. ANNOUNCIATOR50' 18 GA. 2 COND. FPLR UL WIRE. ZONE #28 MMF-301A PWR SUPPLY LOW BAT255' 14 GA. 2 COND. FPLR UL WIRE. ZONE #604 NAC CIRCUITDESCRIPTIONWIRESYMBOL2830604605170' 14 GA. 2 COND. FPLR UL WIRE. ZONE #605 NAC CIRCUIT50' 18 GA. 2 COND. FPLR UL WIRE. ZONE #29 SMOKE DETECTOR29DESCRIPTIONSYMBOLBACK BOX MOUNTING HIEGHT MANUFACTUER MODEL CSFMQTYFACPFAAEOLRE 9200 FIRELITE ALARM CONTROL PANELSUPERVISED REMOTE COMMAND UNIT4S DEEP TOP OF BOX BELOW 60" A.F.FANN-80 7120.0075-0211END OF THE LINE RESISTORN/A N/A N/A N/AN/AFIRE ALARM SYMBOL LEGEND4S DEEPTOP OF BOX BELOW 60" A.F.FFIRELITE9200ULLADA 7165.0075:0217PWR SUPXXHORN/STROBE (CANDELA SHOWN)SA-WBBBOTTOM OF BOX 80" A.F.FOR CEILINGXXSTROBE (CANDELA SHOWN) 9P2RL-PC2RLSYSTEM SENSOR7125-1653:0517SR OR SCR*K = WPSYSTEM SENSORSA-WBBBOTTOM OF BOX 80" A.F.FOR CEILING7125-1653:0504802ULADA POWER SUPPLY4S DEEP TOP OF BOX BELOW 60" A.F.FAL802ULADA 7315-1335:0107EXISTINGANSULMMF-301AANSUL ALARMN/A4S DEEP7300-0075:0185 1 1smk 1FIRELITEALTRONIX 6EXISTINGFIRELITEFIRELITE SMOKE DETECTOR4S DEEPCEILINGFIRELITESD3657272-0075:0502FIRE ALARM NOTES1. The applicable codes and standards are the 2019 California FireCode (CFC),2019 California Building Code (CBC) and NFPA 72.2. The system shall be pre-tested prior to inspection to determine thatthe system is properly installed and functions in accordance with the approved plans and the manufacturer'sinstallation and maintenance manual. (NFPA 72 7.5.2)3. Upon completion, a copy of "as built" drawings and written operationand maintenance instructions shall be provided to theowner/occupant.4. A 24-hour emergency response phone number shall be permanentlyposted adjacent to the control panel.5. The installing contractor shall provide an Record of Completion to theinspector and to the business owner following completion of alarmtesting as witnessed by. (CFC 907.7.2)6. Automatic fire sprinkler water flow alarms, supervisory initiatingdevices, and their circuits, shall be designed and installed so thatthey cannot be readily tampered with, opened, or removed withoutinitiating a signal.7. Through penetration fire stopping for all fire walls, floor/ceilings, andassemblies shall have an "F" or "T" rating per the CBC andstandards. Installation of fire stopping shall comply with approvedmethods.8. The circuit disconnect breaker providing power to the fire alarm unitshall only be accessible to authorized personnel, and shall beidentified as "FIRE ALARM CIRCUIT".9. All fire control units shall be interconnected with all other fire alarmcontrol units located within the facility. (NFPA 72: 23.8.2.1. 23.8.2.2and 23.8.2.3)10. All audible alarm notification signals shall be a three pulse temporalpattern. (CFC 907.5.2.1.3)11. Audible alarm should sound level shall be the minimum specified byCFC 907.5.2.1.12. When more than two visual notification appliances are located withinthe same room or area, they shall be synchronized. (NFPA 72:18.5.5.4.2)13. All fire sprinkler systems shall be monitored except those noted inCFC 903.414.Where a building fire alarm or monitoring system is installed,automatic fire- extinguishing systems shall be monitored by thebuilding fire alarm or monitoring system in accordance with NFPA72. (CFC 904.3.5)SEQUENCE OF OPERATIONSPULL STATION SMOKE DET. HVAC DUCT DET. POWER FAILURE SYSTEM TROUBLE WATERFLOW SW. VALVE TAMPER SW.ANNUNCIATE AT PANEL YES YES YES YES YES YES YESANNUNCIATE AT REMOTE ANNUNCIATOR YES YES YES YES YES YES YESSOUND AUDIBLE DEVICES YES YES NO NO NO YES NOACTIVATE CENTRAL STATION CONNECTION-ALARM YES YES NO NO NO YES NOACTIVATE CENTRAL STATION CONNECTION-SUPERVISORY NO NO YES NO NO NO YESACTIVATE CENTRAL STATION CONNECTION-SYSTEM TROUBLE NO NO NO YES YES NO NOSOUND EXTERIOR WATERFLOW ALARM BELL NO NO NO NO NO YES NO2 WIRE NON SHIELDEDTYPICAL WIRING TO SD MON-2ONSCOPE OF WORKResturant TI has an existing Fire System thatincludes (3) existing appliances and Ansul cook hoodfire alarm monitors.The Installation includes theaddition of (9) strobe only appliances and (6)Horn/Strobes tied into a new NAC power supply withone smoke Detector above the Power Supply andone Announciator in th Lobby.(+)(-)EOLRFROMFACP(+)(-)EOLRFROMFACPSPRENCLER FLOW SWITCH SPRENCLER FLOW SWITCH(+)(-)EOLRFROMFACPFOST INDICATOREOLRALARM HORNSEOLRMANUAL PULL STATIONS(+)(-)FROMFACP(+)(-)FROMFACPEOLRSTROBE LIGHTS(+)(-)FROMFACPEOLRSMOKE/HEAT DETECTORS(+)(-)FROMFACPWIRE DESIGNATION CHARTNAC #604 VOLTAGE DROP24-HOUR BATTERY CALCULATIONPOWER SUPPLYNAC #605 VOLTAGE DROPSYSTEM INSTALLATIONBYCOMTRON SYSTEMS, INC.41-651 CORPORATE WAYSUITE 6PALM DESERT, CA 92260TELE: (760) 776-8811STATE CONTRACTORSC-10 LIC#:530025PROJECT TITLESCALE:DATE:DRAWING NUMBER: 1 of 1PROJECT NUMBER:CHECKED BY: APREVISIONSRESTURANT T.I.78-065 MAIN ST.OLD TOWN SUITE 201LA QUINTA, CA. 9225312/19/22SITE MAP:SCALE: 1/8":1'FIRE ALARM PLANSYSTEM DESIGN / INSTALLER COMPANY - COMTRON SYSTEMSADDRESS - P.O. BOX 13470 PALM DESERT, CA 92255-3470TELE: 760-776-8811C-10 LIC#:530025APPLICABLE DATAOCCUPANCY: A-2OCCUPANT LOAD: 1247CONSTRUCTION TYPE: TYPE VB,BUILDING SQ. FOOTAGE:TOTAL BUILDING = 37,978 S.F.FIRE SPRINKLER COVERAGE THROUGHOUTUL CENTRAL STATION SERVICEBY TRI-STAR MONITORING1255 GRAPHITE DRIVECORONA, CA. 92881DESIGNED BY: MONTY SORENSENW116715RESTAURANT FIRE SYSTEM T.I.MONITOR-MMF-301APOW SUPUPPO FIRE ALARM SYSTEM TENANT IMPROVEMENT PLAN CHECK: DESIGNED BY: Comtron Systems, Inc. 41-651 Corporate Way Suite 6 Palm Desert, CA 92260 OWNERS: Marvin Wells, LLC 78-015 Main St. La Quinta, Ca. 92253 FOR: Old Town La Quinta 78-065 Main St.. La Quinta, Ca. 92253 GENERAL CONTRACTOR Marvin Wells, LLC 78-015 Main St. La Quinta, Ca. 92253 This has an occupancy rating of A-2 Occupancy Load is 167 Occupancy Type - VB Fully Sprinkler Fire Monitoring System Fire Sprinkler Alarm System Designed per NFPA 72 NEC 2019 with California Amendments, CFC 2019 with California Amendments, CBC 2019 with California Amendments SYSTEM DESCRIPTION The Fire System is based on an existing Firelite 9200udls. This is 24 volt 198 zone Control Panel. We are providing a tenant improvement for a Restaurant in Ste.#201 The Panel has an integrated digital communicator, and will be equipped with a supervised dual phone line module communication. The Firelite 9200udls is U.L. Listed Power Limited, and meets all NFPA 72 requirements. This system is designed to provide sprinkler water flow and supervisory signal service in accordance with NFPA 72, sec. 26 2019 Edition. Local notification is also transmitted to our U.L. approved monitoring facility. Upon sensing of visible or invisible particles of combustion, the respective devices shall cause an indication of alarm to be received by the fire alarm control panel. The panel shall cause all indicating devices to operate. The respective zone shall be identified at the panel and an appropriate signal shall be transmitted to the receiving monitoring facility for disposition in accordance with NFPA 72, sec. 17 2019 Edition. Upon leak or flow of water of 10 gallons per minute, the flow switch shall close with the respective device causing an indication of alarm to be received by the fire alarm control panel. The panel shall cause all indicating devices to operate. The respective zone shall be identified at the panel, and appropriate signal shall be transmitted to the receiving station for disposition in accordance with NFPA 72, sec. 17 2019 Edition. Upon movement of a fire protection system control valve from an open position, and during the first two revolutions, an indication of an alarm shall be interpreted by the fire alarm control panel and appropriate Valve Tamper signal shall be transmitted to our U.L. central Monitoring Facility for disposition in accordance with NFPA 72, sec. 17 2019 Edition. The occurrence of any trouble of any nature such as circuit wiring break or ground fault occurring in the devices or wiring associated with the protective signaling system shall cause a (distinctive signal to be received by the fire alarm control panel, and a appropriate signal shall be transmitted to our U.L. Central station facility for disposition in accordance with NFPA 72, sec 17 2019 Edition. • Two (2) Class A or two (2) Class B FACP inputs. • Two (2) NC dry contact trigger inputs (AL802ULADA and AL1002ULADA only) • Two (2) Class A or four (4) Class B indicating circuits. • Two (2) Class B outputs may be paralleled for more power on an indicating circuit. • One (1) Aux. Power Output @ 1 amp supply current (w/battery back up). • Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LED’s indicate a prior fault (short, open, ground) has occurred on one or more signaling circuit outputs. • 2-wire Horn/Strobe Sync mode allows audible notification appliances (Horns) to be silenced while visual notification appliances (Strobes) continue to operate. • Horn/Strobe sync protocols include: Gentex®, System Sensor®, Faraday, Amseco. • Temporal Code 3 Mode. • Steady Mode. • Input to Output Follower Mode (maintains synchronization of notification appliance circuits). • March Time. • Compatible with 24VDC or 12VDC fire panels. • Common trouble inputs and outputs. • Ground fault detection. • Input 115VAC. • AC fail supervision (form "C" contacts). • Low battery supervision (form "C" contacts). • Battery presence supervision (form “C” contacts). • Power supply, logic board, red enclosure, cam lock, transformer & battery leads. • Enclosure: - Combination knockouts re 1/2” and 3/4” - Accommodates up to two (2) 12VDC/12AH batteries. AL602ULADA, AL802ULADA, AL1002ULADA NAC Power Extenders Rev. AL602/802/1002ULADA- L20E Overview Specifications Agency Approvals AL602ULADA • 24VDC or 12VDC rated @ 6.5 amp max. • Two (2) Class A or four (4) Class B outputs. AL602ULADAJ • Larger enclosure. AL802ULADA • 24VDC or 12VDC rated @ 8 amp max. • Two (2) Class A or four (4) Class B outputs. AL802ULADAJ • Larger enclosure. AL1002ULADA • 24VDC rated @ 10 amp max. • Two (2) Class A or four (4) Class B outputs. AL1002ULADAJ • Larger enclosure. UL Listed Control Units and Accessories for Fire Alarm Systems (UL 864), UL Listed Standard for Safety for Fire Protective Signaling Systems (UL 1481). Factory Mutual Approved.NYC Department of Buildings Approved. California State Fire Marshal Approved. • The AL602ULADA, AL802ULADA and AL1002ULADA are extremely cost effective voltage regulated remote NAC Power Extenders. They may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to support system accessories. Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com Enclosure Dimensions AL602ULADA, AL802ULADA and AL1002ULADA: 15.5"H x 12"W x 4.5"D .875" 1" 1.3"9.97" 13.53" 6.625" 2.25"3.68"4.56" 1.22" 1.22" 3.5" 1" 13.25" 2" 1.22" 12" 15.5" 4.5" 2.25"3.68"4.56" 1.22" 1.25" 2.2" 1" 18"18" 14.5" 14.5" 4.5" 4.5" 4.5" 4.5" 4.5" 18" 1.25" 1.5"4.0"6.5"1.5"1.25" 1.5" 4.0" 10.0" 1.25" 2.75"7.25" 1.0" 1.5" 1.0" 1.0" 1.0" 1.25" 2.75" 1.5" 10" AL602ULADAJ, AL802ULADAJ and AL1002ULADAJ: 18"H x 14.5"W x 4.625"D DF-52417:D • 3/15/2018 — Page 1 of 2 ANN-80 80-Character Serial LCD Annunciator Annunciators DF-52417:D • B-90 General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employ- ing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point informa- tion including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-Bus of each FACP. No programming is required, which saves time during system commissioning. Features • Listed to UL Standard 864, 9th Edition •Backlit 80-character LCD display (20 characters x 4 lines) •Mimics all display information from the host panel •Control switches for System Acknowledge, Signal Silence, Drill, and Reset •Control switches can be independently enabled or disabled at the FACP •Keyswitch enables/disables control switches and mechanically locks annunciator enclosure •Keyswitch can be enabled or disabled at the FACP •Enclosure supervised for tamper •System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence •Local sounder can be enabled or disabled at the FACP •ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming •Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels •Time-and date display field •Surface mount directly to wall or to single, double, or 4" square electrical box •Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting •Can be remotely located up to 6,000 feet (1,800 m) from the panel •Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs •May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC) • Up to eight ANN-80s can be connected on the ANN-Bus Controls and Indicators •AC Power •Alarm • Trouble • Supervisory • Alarm Silenced Specifications •Operating voltage range: 18 VDC to 28 VDC •Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum •Ambient temperature: 32°F to 120°F (0°C to 49°C) •Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F) •5.375” (13.65 cm.) high x 6.875” (17.46 cm.) wide x 1.375” (3.49 cm.) deep •For use indoors in a dry location •All connections are power-limited and supervised The ANN-Bus POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- IARY POWER SUPPLY The ANN-Bus can be powered by an auxiliary power supply when the maximum number of ANN-Bus devices exceeds the ANN-Bus power requirements. See the FACP manual for more information. ANN-BUS DEVICE ADDRESSING Each ANN-Bus device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-Bus communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-Bus communications cir- cuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-Bus refer to appropriate FACP manual. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Page 2 of 2 — DF-52417:D • 3/15/2018 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Country of Origin: USA WIRE REQUIREMENTS: POWER CIRCUIT • 14 to 18 AWG (0.75 - 2.08 mm 2) wire for 24 VDC power circuit is acceptable. Power wire distance limitation is set by 1.2 volt maxi- mum line drop form source to end of circuit. • All connections are power-limited and supervised. • A maximum of eight ANN-80 modules may be connected to this circuit. Ordering Options ANN-80: Red 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80KIT-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agen- cies, or listing may be in process. Consult factory for latest listing status. •UL: S2424 • FM approved •CSFM: 7120-0075:0211 •MEA: 442-06-E DF-52121:E • 07/30/2015 — Page 1 of 4 MMF-300(A) Series, MDF-300 Addressable Monitor Modules Addressable Devices DF-52121:E • E-325 General Four different monitor modules are available for Fire•Lite’s intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeed™ is a communication protocol developed by Fire•Lite Engineering that greatly increases the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. MMF-300(A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address: 01 – 159 on MS-9600 series panels, 01 – 99 on other compatible systems. • LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 µA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301(A) Mini Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. MMF-300(A) (Type H)6999cov.jpg Page 2 of 4 — DF-52121:E • 07/30/2015 • Tinned, stripped leads for ease of wiring. • Direct-dial entry of address: 01 – 159 on MS-9600 series panels, 01 – 99 on other compatible systems The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301(A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 µA, 1 communication every 5 seconds, 47k EOL; 600 µA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 µA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF-302(A) Interface Module • Supports compatible two-wire smoke detectors. • Supervises IDC wiring and connection of external power source. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry entry of address: 01 – 159 on MS-9600 series panels, 01 – 99 on other compatible systems. • LED flashes during normal operation. • LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 µA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals T10 and T11): • DC voltage: 24 volts power limited. • Ripple voltage: 0.1 Vrms maximum. • Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED.6720m101.wmf DF-52121:E • 07/30/2015 — Page 3 of 4 NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 µA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 µA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address “26”, then it will automati- cally assign itself to addresses “26” and “27”. NOTE: “Ones” addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL: S2424. •ULC: S2424. •FM Approved. •CSFM: 7300-0075:0185. •MEA: 72-01-E. Product Line Information NOTE: “A” suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects’/Engineers’ Specifications Specifications of these devices and all FireLite products are available from FireLite. CAUTION: Avoid duplicating addresses on the system. Page 4 of 4 — DF-52121:E • 07/30/2015 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Fire·Lite® is a registered trademark and LiteSpeed™ and FireWatch™ are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. DF-61010:C • 5/28/2020 — Page 1 of 3 SD365 Series Addressable Photoelectric Smoke Detectors Addressable Devices DF-61010:C The Fire•Lite® Alarms SD365(A), SD365R(A), and SD365HT(A) intelligent plug-in smoke detectors are designed for both perfor- mance and aesthetics, and are direct replacements for the SD355 Series. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more strin- gent code standards. Exclusively for use with Fire•Lite’s addressable fire alarm control panels, the SD365(A) Series point ID capability allows each detec- tor’s address to be set with rotary, decimal address switches, provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The SD365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the SD365T(A) and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP: • Two-wire SLC loop connection • Unit uses base for wiring • Compatible with LiteSpeed™ and CLIP protocol systems • Stable communication technique with noise immunity ADDRESSING: • Addressable by device • Rotary, decimal addressing (Refer to the Fire•Lite panel manuals for device capacity.) ARCHITECTURE: • Sleek, low-profile, stylish design • Unique single-source design to respond quickly and dependably to a broad range of fires • Integral communications and built-in device-type identification • Built-in tamper resistant feature • Remote test feature from the panel • Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1(LiteSpeed systems only) • Built-in functional test switch activated by external magnet • Removable cover and insect-resistant screen for simple field cleaning • Expanded color options OPERATION: • Designed to meet UL 268 7th Edition • Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level • LED “blinks” when the unit is polled (communicating with the fire panel) and latches in alarm. • Low standby current MECHANICALS: • Sealed against back pressure • SEMS screws for wiring of the separate base • Designed for direct-surface or electrical-box mounting • Plugs into separate base for ease of installation and maintenance • Separate base allows interchange of photoelectric, ionization and thermal sensors OPTIONS: • Optional relay, isolator, and sounder bases Installation SD365 Series plug-in intelligent smoke detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Class “B” wiring only. When using relay or sounder bases, consult the I300(A) installation sheet I56-3626 for device limitations between isolator modules and isola- tor bases. Construction These detectors are constructed of fire-resistant plastic. The SD365 Series plug-in intelligent smoke detectors are designed to commer- cial standards and offer an attractive appearance. Operation Each SD365 Series detector uses one of the panel’s addresses (total limit is panel dependent) on the Fire•Lite Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SD365 Series offers features and performance that represent the latest in smoke detector technology. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an Fire•Lite addressable fire alarm control panel. The results of the sensitivity test can be printed for record keeping. Page 2 of 3 — DF-61010:C • 5/28/2020 Product Line Information NOTE: “-IV” suffix indicates CLIP and LiteSpeed device. NOTE: “A” suffix indicates Canadian version. SD365: White, low-profile intelligent photoelectric sensor, LiteSpeed only SD365A: Same as SD365 but with ULC listing SD365-IV: Ivory, low-profile intelligent photoelectric sensor SD365A-IV: Same as SD365-IV but with ULC listing SD365T: White, same as SD365 but includes a built-in 135°F (57°C) fixed-temperature thermal device, LiteSpeed only SD365TA: Same as SD365T but with ULC listing SD365T-IV: Ivory, same as SD365T but includes a built-in 135°F (57°C) fixed-temperature thermal device SD365TA-IV: Same as SD365T-IV but with ULC listing SD365R: White, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW, LiteSpeed only SD365RA: Same as SD365R but with ULC listing, for use with DNRA SD365R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW SD365RA-IV: Same as SD365R-IV but with ULC listing, for use with DNRA INTELLIGENT BASES NOTE: For details on intelligent bases, see DF-60059. B300-6: White, 6” base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-6-IV: Ivory,6” base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300A-6: Same as B300-6, ULC listed B300A-6-IV: Ivory, 6” standard flanged low-profile mounting base, ULC listed B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4” standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-BL: Black, 4” standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4” standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501-WHITE contains 10 B224RB-WH: White, relay base (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B224BI-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224BI-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B224BIA-WH: White, isolator detector base, ULC listing B224BIA-IV: Ivory isolator detector base, ULC listing B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses LiteSpeed protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses LiteSpeed protocol. (CSFM: 7300-1653:0213) B200SA-WH: Same as B200S-WH, ULC listing B200SA-IV: Same as B200S-IV, ULC listing B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A) base TR300-IV: Ivory, replacement flange for B210LP(A) base RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B300-6(A). M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: Color Kit (includes cover and trim ring), white, 10-pack CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack LiteSpeed™ is a trademark, and Fire•Lite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2020 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Page 3 of 3 — DF-61010:C • 5/28/2020 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX:(877) 699-4105. www.firelite.com Country of Origin: Mexico SYSTEM SPECIFICATIONS Sensitivity: • UL Applications: 0.5% to 4.0% per foot obscuration. • ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0" (51mm) high; base determines diameter – B300-6: 6.1" (15.6 cm) diameter – B501: 4" (10.2 cm) diameter For a complete list of detector bases see DF-60983 Shipping weight: 3.4 oz. (95 g) Operating temperature range: • SD365: 32°F to 122°F (0°C to 50°C) • SD365T Series: 32°F to 100°F(0°C to 38°C) • SD365R Series installed in a DNR/DNRW, -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10% – 93% non-condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200µA @ 24 VDC (o ne communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC (“ON”) DETECTOR SPACING AND APPLICATIONS Fire•Lite recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document SPAG91, is available at www.systemsensor.com. Listings and Approvals Listings and approvals below apply to the SD365 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC Listing: S1059 • FM Approved • CSFM: 7272-0075:0502 Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383 AVDS868-02 • 12/01/2017 • Page 3 AVDS868-02 • 12/01/2017 • Page 2 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11 ⁄16 × 4 11 ⁄16 × 2 1 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3)8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02 • 12/01/2017 • Page 3 Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 UL Current Draw Data Horn Strobe Tones and Sound Output Data UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), Ceiling Horn Strobe, Candela Range (15–177 cd) DC Input 8–17.5 Volts 16–33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16–33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS868-02 • 12/01/2017 L-Series Dimensions Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White L-Series Ordering Information Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Model Description Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 6.83" diam. (173 mm) 2.47" (62.7 mm) 1.37" (34.8 mm)6.92" diam. (175.77 mm) 2.5" (64 mm) 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box A0531-01 A0545-00 A0546-00 A0494-01 For a ceiling-listed horn-only device, see AVDS865 “Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications”. LISTING No.:7161-0060:0103 CATEGORY:7161 - CABLES-FIRE PROTECTIVE SIGNALING LISTEE:Belden Wire & Cable 2200 U.S. Highway 27 South, Richmond, IN, 47374 Contact: Dorna,Gerald (775) 806-2991 Email: gerald.dorna@belden.com DESIGN: Type FPLR power-limited fire protective signaling cable. Refer to listee's data sheet for detailed product description and operational considerations. Insulation: Semi-rigid PVC compound No. 70 through X79, X960 through X979, X2000 through X2049 or X-20 through X-39, X2400 through X2419, X-6501 through X-6539, or Geon 8891. Shields: (Optional) metal or polyethylene terephthalate/metal tape shield. Core Wrap: (Optional) Glass Reinforced TFE (Teflon) impregnated tape or polyethylene terephthalate. Filler: (Optional) PVC or polypropylene. Jacket: PVC Compound No. X-99000 through X-99199 or X-199000 through X-199199. RATING: INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, type, classification and UL label. APPROVAL: Listed as power-limited fire protective signaling cable. NOTES: This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/01/2022 Listing Expires: 06/30/2023 *Rev. 03-20-06 Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.:7315-1335:0107 CATEGORY:7315 - POWER UNITS LISTEE:Altronix 140 58th Street, Bldg A, Ste 2N, Brooklyn, NY, 11220 Contact: Zatz,Gary (718) 567-9056 Email: garyz@altronix.com DESIGN: Models AL800UL-ADA and AL802UL-ADA Indicating Circuit Power Supply. Unit is a regulated 12 or 24 VDC power supply/charger used for supervision and expanded power driving capability of up to four notification appliance circuits. The unit is intended for use with Altronix's Model EOL22 end-of-line risistor package. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC input, 12 or 24 VDC output INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. *Model AL802UL-ADA is capable of providing synchronization out of Gentex, Faraday, System Sensor and AMSECO appliances. NOTES: For fire alarm use, the standby batteries must provide at least 24 hours standby power during power loss. The battery circuit must be fully supervised. This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/04/2022 Listing Expires: 06/30/2023 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division *Rev. 07-16-01 Page 1 of 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.:7300-0075:0185 CATEGORY:7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE:FIRE-LITE ALARMS INC. One Fire-Lite Place, Northford, CT, 06410 Contact: Brant, Lisa (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTES:   This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 06/10/2022 Listing Expires: 06/30/2023 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division *Rev. 05-06-05 JW Page 1 of 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.:7272-0075:0502 PARENT LISTING No.:7272-0028:0503 CATEGORY:7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE:FIRE-LITE ALARMS INC. One Fire-Lite Place, Northford, CT, 06410 Contact: Brant, Lisa (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models SD365, SD365R and SD365T analog addressable, photoelectric smoke detectors for open area and duct installations. Model SD365T has a complementary heat detector. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models *B501, *B210LP (CSFM Listing 7300-1653:0109), *B350LP (CSFM Listing 7300-0075:0192), B200S and B200SR (CSFM Listing 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209), Fire-Lite duct detector housing Model D355PL (CSFM listing 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturer’s Installation Manual for details. *All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition, January 11, 2016. Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE NOTES: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test resultsand/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 06/10/2022 Listing Expires: 06/30/2023 Authorized By: Victor Wong , Program Coordinator Fire Engineering & Investigations Division *Revision 12-17- 19 VWW Page 2 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.:7125-1653:0517 CATEGORY:7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE:System Sensor, Unincorporated Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant,Lisa (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models P2RL-LF and P2WL-LF are low frequency *wall horn/strobes. *Models PC2RL-LF and PC2WL- LF are low frequency ceiling horns/strobes. For these models, the horn has a 6 position selectable tone settings. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC INSTALLATION: In accordance with the listee’s printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, date of manufacturer, model number, electrical ratings, audibility ratings, and UL label. APPROVAL: Listed as horn/strobes when used with separately listed compatible fire alarm control units. For indoor dry use. Operating Temperature Range: 0°C to 49°C (32°F to 120°F). Authority having jurisdiction should be consulted prior to installation. Refer to listee’s Installation Instruction Manual for details. NOTES: This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/20/2022 Listing Expires: 06/30/2023 *Revision 08-28-20 VWW Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.:7125-1653:0504 CATEGORY:7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE:System Sensor, Unincorporated Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant,Lisa (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee’s Installation Instruction Manual for details. NOTES: This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/20/2022 Listing Expires: 06/30/2023 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division *Rev 04-04-19 gt Page 2 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org January 4, 2023 COMTRON 41651 Corporate Way #6 Palm Desert, CA 92260 Re: Fire Alarm System Plan Review – RD RNNR FA2022-0014 / 78065 MAIN STREET #200, LA QUINTA, CA 92253 The fire alarm system plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Duct Detector / Velocity Testing – Requires provision of magnometer/magnahelic gauge. c) Function Test / Start 24-hour Battery - The alarm installer shall provide all needed testing equipment to complete the final alarm inspection. d) 5-Minute Ring-out / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78065 MAIN STREET #200 PERMIT#: FA2022-0014 DATE ISSUED: 1/4/2023 DESCRIPTION: RD RNNR – NOTIFICATION ALARM SYS CONTRACTOR: COMTRON HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Insp ector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.