Loading...
FA2023-0001ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT TRL SYSTEMS INCORPORATED 9531 MILLIKEN AVE RANCHO CUCAMONGA CA 91730 (909)390-8392 ACCOUNTING@TRLSYS TEMS.COM BILL TO TRL SYSTEMS INCORPORATED 9531 MILLIKEN AVE RANCHO CUCAMONGA CA 91730 (909)390-8392 sboice@trlsystems.co m CONTRACTOR TRL SYSTEMS INCORPORATED 9531 MILLIKEN AVE RANCHO CUCAMONGA CA 91730 (909)390-8392 ACCOUNTING@TRLSYS TEMS.COM OWNER Welbehealth La Qunita 46-805 Dune Palms Rd.La Qunita CA 92253 (909)390-8392 allison@goldenconst.c om CONDITIONS Description: INSTALL NEW FIRE ALARM SYSTEM ( 89 FA DEVICES) Type: FIRE ALARM (WEB)Subtype: COMMERCIAL - FIRE ALARM SYSTEM Status: FINALED Applied: 1/25/2023 ECON Parcel No: 600390023 Site Address: 46805 DUNE PALMS RD RD LA QUINTA,CA 92253 Approved: 5/15/2023 KHET Subdivision: Block: Lot: Issued: 6/5/2023 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 7/26/2023 KHET Valuation: $29,300.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Thursday, July 27, 2023 3:17:38 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2023-0001 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH-WIRE INSPECTION KHET 6/6/2023 6/6/2023 APPROVED SEE NOTES Redline inspection notes were taken and can be found in the permit attachments. Revised plans are required for review and approval based on as-built conditions, prior to final inspection request. FUNCTION TEST KHET 7/24/2023 7/24/2023 DISAPPROVE D Partially started and ran out of time PIV monitoring was not operating at the maximum 2.5-turns. Need to function test all smoke/pull devices. Technician was trouble shooting the Silence/Resetting of the FACP and was not able to verify AC loss to start 24-hour battery test. FUNCTION TEST KHET 7/25/2023 7/25/2023 APPROVED DUCT DETECTORS/VELOCITY KHET 7/25/2023 7/25/2023 APPROVED DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE ALARM SYSTEMS 101-0000-42421 0 $525.00 $525.00 6/5/23 WEB15339 886166706 CREDIT 413747 ECON FIRE ALARM SYSTEMS PC 101-0000-42420 0 $613.00 $613.00 6/5/23 WEB15339 886166706 CREDIT 413747 ECON Total Paid for FIRE FEES: $1,138.00 $1,138.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 6/5/23 WEB15339 886166706 CREDIT 413747 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $8.00 $8.00 6/5/23 WEB15339 886166706 CREDIT 413747 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $8.00 $8.00 TOTALS:$1,157.00 $1,157.00 Printed: Thursday, July 27, 2023 3:17:38 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2023-0001 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 1/25/2023 Etrakit Contractor 1st SUBMITTAL - FIRE ALARM DRAWINGS 1st SUBMITTAL - FIRE ALARM DRAWINGS.pdf 1 DOC 1/25/2023 Etrakit Contractor 1st SUBMITTAL - FIRE ALARM SPEC BOOK 1st SUBMITTAL - FIRE ALARM SPEC BOOK.pdf 1 DOC 4/21/2023 Etrakit Contractor 2nd SUBMITTAL - FIRE ALARM DRAWINGS 2nd SUBMITTAL - FIRE ALARM DRAWINGS.pdf 1 DOC 4/21/2023 Etrakit Contractor Comment-Response List 2nd SUBMITTAL - Comment-Response List.pdf 1 DOC 6/12/2023 Etrakit Contractor 3RD SUBMITTAL - FIRE ALARM AS-BUILTS 3RD SUBMITTAL - FIRE ALARM DRAWINGS.pdf 1 BOND INFORMATION 24 HR. BATTERY TEST KHET 7/26/2023 7/26/2023 APPROVED FIRE FINAL**KHET 7/26/2023 7/26/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 1/25/2023 2/8/2023 3/23/2023 REVISIONS REQUIRED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 1/25/2023 1/26/2023 1/25/2023 COMPLETE 2ND FIRE - ETRAKIT (1 WK) KOHL HETRICK 4/21/2023 4/28/2023 5/15/2023 APPROVED SEE ATTACHMENTS 3RD FIRE (1 WK)KOHL HETRICK 6/12/2023 6/19/2023 7/13/2023 APPROVED As-Builts PARENT PROJECTS Printed: Thursday, July 27, 2023 3:17:38 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2023-0001 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/23/2023 KOHL HETRICK FA2023-0001 - 1ST REVIEW - FIRE CORRECTIONS.pdf FA2023-0001 - 1ST REVIEW - FIRE CORRECTIONS.pdf 1 DOC 5/15/2023 KOHL HETRICK FA2023-0001 - APPROVED PLANS.pdf FA2023-0001 - APPROVED PLANS.pdf 1 DOC 5/15/2023 KOHL HETRICK FA2023-0001 - PLANS FOR INSPECTION.pdf FA2023-0001 - PLANS FOR INSPECTION.pdf 0 DOC 5/15/2023 KOHL HETRICK FA2023-0001 - COA AND JOB CARD.pdf FA2023-0001 - COA AND JOB CARD.pdf 1 DOC 6/6/2023 KOHL HETRICK FA2023-0001 - Insp Notes 6_6_2023.pdf FA2023-0001 - Insp Notes 6_6_2023.pdf 1 DOC 7/13/2023 KOHL HETRICK FA2023-0001 - AS- BUILTS - APPROVED.pdf FA2023-0001 - AS- BUILTS - APPROVED.pdf 1 DOC 7/26/2023 KOHL HETRICK FA2023-0001 - NPFA 72 - REC OF COMPLETION.pdf FA2023-0001 - NPFA 72 - REC OF COMPLETION.pdf 1 Printed: Thursday, July 27, 2023 3:17:38 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FA2023-0001 SystemsWhen Reliability CountsN I C E TCERTIFIEDNICET certificationWe support and encourageFILE #S36741Professional Stamp:Agency Stamp:Project Name:REVISION / ISSUENO.DATEThese drawings and specifications are the property and copyright of TRLSystems, Inc. and shall not be used on any other work except by writtenagreement with TRL Systems, Inc. All Rights Reserved.Date:COPYRIGHT - 2023CScale:TRL Proj. #OfSheetsSheet Number:Drawn By:Sheet Title:Facility:Tel: 800.266.1392909.390.8392Fax: 909.390.8397www.trlsystems.comEmail: info@trlsystems.comLic. #: C10/C16 - 413747Rancho Cucamonga - Corporate Headquarters:9531 Milliken Avenue, Rancho Cucamonga, CA 91730Burbank - Regional Office:695 South Glenwood Place, Burbank, CA 91506Tustin - Regional Office:1451 Edinger Avenue, Suite #A, Tustin, CA 92780San Diego - Regional Office:9155 Brown Deer Road, Suite #7, San Diego, CA 92121Y.L./I.L.13852AS NOTED03.24.230546805 DUNE PALMS RD. LA QUINTA, CA 92253 MSD WELBEHEALTH LA QUINTA PACE CENTER FIRE ALARM SYSTEM INSTALLATION EXP. 11/30/2023NO. 413747CALI FORN IA DRAOBENECILETATSRO T CARTNOC STATEOFSC TRL S Y S TEMS, INCORPORATED ELECTRICAL C10/ C 16 04.18.23CITYREVISIONY.L.06.08.23AS BUILTY.L.INTELLIGENT OPTICAL SMOKE DETECTOR4-INCH DETECTOR MOUNTING BASE WITH TRIM SKIRTEDWARDS #SIGA-OSDEDWARDS #SIGA-SB4EDWARDS #SIGA-270MANUAL PULL STATIONSYMBOLQTY. OFNEW DEVICESMODEL NUMBERDESCRIPTIONMOUNTS TO DETECTOR BASESINGLE GANG BOX, DEEP, VERTICALSTANDARD 4" SQUARE, DEEP, BOX WITH 3-0 PLASTER RING7150-1657:01297300-1657:0120BACK BOX REQUIREMENTSCSFM LISTING7272-1657:0511PEDWARDS #iO1000RDFIRE ALARM CONTROL PANELSURFACE MOUNT 15.75" x 28" x 3.85" (W,H,D)7165-1657:0244EDWARDS #SIGA-CT1INPUT MODULE7300-1657:0121SINGLE GANG, 2-1/2" DEEP, BOXCELLULAR COMMUNICATORTELGUARD #TG7LVF01SURFACE MOUNT WALLBOX - 12.5" x 12.5" x 4.25" (W,H,D)7300-1402:0110SYMBOL LEGENDEDWARDS #SIGA-LEDREMOTE ALARM LEDSINGLE GANG BOX, DEEP7300-1657:0127INTELLIGENT DUCT SMOKE DETECTOR HOUSINGMOUNTS TO DUCT3240-1657:0517EDWARDS #SIGA-SDHINTELLIGENT OPTICAL SMOKE DETECTOREDWARDS #SIGA-OSDMOUNTS TO DETECTOR BASE7272-1657:0511-------------END OF LINE RESISTORSPACE AGE #ACE-11SYSTEM RECORD DOCUMENTS CABINET REDSURFACE MOUNT WALLBOX - 12" x 13" x 2 1/4" (H,W,D)7300-0553:01101EDWARDS #SA-232SLIDE INTO SLOT PROVIDEDRS232 INTERFACE CARD7165-1657:0244LCD TEXT ANNUNCIATORSTANDARD 4" SQUARE BOX, 2-1/8" DEEPEDWARDS #RLCD-C7120-1657:0254WEATHERPROOF WALL MOUNT HORN/STROBE -FIELD SELECTABLE 6, 12, 28 & 35cdEDWARDS #WG4WF- HVMC7125-1657:0311MOUNT TO 449 WEATHERPROOF BACK BOXEDWARDS #449EDWARDS #WG4WTSWEATHERPROOF BACK BOXSURFACE SKIRT FOR GENESIS WG4 APPLIANCE FAMILY, WHITESURFACE MOUNT TO WALLCDWATER FLOW SWITCH (EXISTING TO REMAIN)VALVE TAMPER SWITCH (EXISTING TO REMAIN)POTTER #PCVS-1 (OR EQUIVALENT)POTTER #VSR-F (OR EQUIVALENT)VSWFRISER UP/DOWNEDWARDS #SIGA-CT2DUAL INPUT MODULE7300-1657:0121SINGLE GANG, 2-1/2" DEEP, BOXCT2------------------------------------------------------------------------------------------------------------------------------------------111117733371222------------EDWARDS #SA-DACTDIALER (DACT) MOUNTS TO LOCAL RAIL7165-1657:02441TELGUARD #TG-PEMPOWER AND EXPANSION MODULE7300-1402:0501MOUNT INSIDE DIALER CABINET1WALL MOUNT LED HORN/STROBE - FIELD SELECTABLE 15, 30, 75 & 110 cdEDWARDS #G4AVWF7125-1657:0504ATTACH TO WIRING PLATECD161666CONTROL RELAY MODULEEDWARDS #SIGA-CRCONTROL RELAYSINGLE GANG, DEEP, BOX7300-1555:01007300-1657:0121FUNCTIONAL DEVICES, INC. #RIBU1CSINGLE GANG, 2-1/2" DEEP, BOXRRCDWALL MOUNT LED STROBE - FIELD SELECTABLE 15, 30, 75 & 110 cdEDWARDS #G4VWF7125-1657:0505ATTACH TO WIRING PLATE3636JUNCTION BOX (SIZE PER C.E.C.)J---------------------------------------POTTER #PCVS-1 (OR EQUIVALENT)DENOTES ELEVATOR RECALLDUCT DETECTOR MOUNTING PLATESTANDARD DETECTOR MOUNTING BASEEDWARDS #SIGA-SBEDWARDS #SIGA-DMP-------------MOUNTS TO PLATEMOUNTS TO DUCTNOT APPLICABLEER7300-1657:0120INTELLIGENT OPTICAL SMOKE DETECTOREDWARDS #SIGA-OSDMOUNTS TO DETECTOR BASE7272-1657:0511EDWARDS #GCAVWFCEILING MOUNT LED HORN/STROBE - FIELD SELECTABLE 15, 30, 75 & 115cdATTACH TO WIRING PLATECD7125-1657:0515EDWARDS #GRSWROOM SIDE WIRING PLATE (ORDERED IN PACKS OF 10 - GRSW-10)STANDARD 4" SQUARE BOX, 2-1/8" DEEP WITH 4S EXTENSION RING7320-1657:0516POST INDICATOR VALVE (EXISTING TO REMAIN)PIVASDEDWARDS #SIGA-CT1INPUT MODULE7300-1657:0121SINGLE GANG, 2-1/2" DEEP, BOXCT14-INCH DETECTOR MOUNTING BASE WITH TRIM SKIRTINTELLIGENT FIXED TEMPERATURE/RATE-OF-RISE HEAT DETECTOREDWARDS #SIGA-SB4EDWARDS. #SIGA-HRDMOUNTS TO DETECTOR BASESTANDARD 4" SQUARE, DEEP, BOX WITH 3-0 PLASTER RING7270-1657:03337300-1657:0120EDWARDS #GRSWROOM SIDE WIRING PLATE (ORDERED IN PACKS OF 10 - GRSW-10)STANDARD 4" SQUARE BOX, 2-1/8" DEEP WITH 4S EXTENSION RING7320-1657:0516EDWARDS #GRSWROOM SIDE WIRING PLATE (ORDERED IN PACKS OF 10 - GRSW-10)STANDARD 4" SQUARE BOX, 2-1/8" DEEP WITH 4S EXTENSION RING7320-1657:0516221-------------COMBINATION SMOKE/FIRE DAMPER (EXISTING TO REMAIN)CSFD----------------------------------------------------DENOTES EXISTING DEVICE TO REMAINE---------------------------------------33322---112EDWARDS #SIGA-CT1INPUT MODULE7300-1657:0121SINGLE GANG, 2-1/2" DEEP, BOXCONTROL RELAY MODULEEDWARDS #SIGA-CR7300-1657:0121SINGLE GANG, 2-1/2" DEEP, BOXCONTROL RELAYSINGLE GANG, DEEP, BOX7300-1555:0100FUNCTIONAL DEVICES, INC. #RIBU1CALARM DESIGN CRITERIA1.OCCUPANCY TYPE: I-4/B2.CONSTRUCTION TYPE: TYPE V-B3.AREA OF WORK:FIRST FLOOR 12,641 SQUARE FEET (APPX.)SECOND FLOOR 5,338 SQUARE FEET (APPX.)TOTAL AREA 17,979 SQUARE FEET (APPX.)4.TYPE OF ALARM SYSTEM: POWER LIMITED ANALOG ADDRESSABLE FIRE ALARM SYSTEM.5.SCOPE OF PROJECT:FURNISH AND INSTALL THE FOLLOWING DEVICES AS A PART OF THE NEW FIRE ALARMSYSTEM INSTALLATION IN THE PROJECT AREA.·NEW IO1000RD FIRE ALARM CONTROL PANEL IN FIRE RISER ROOM - FIRST FLOOR.·NEW REMOTE ANNUNCIATOR IN THE RECEPTION - FIRST FLOOR.·NEW CELLULAR COMMUNICATOR.·NEW VISUAL AND AUDIO/VISUAL NOTIFICATION DEVICES AS REQUIRED BY THE CODE.·NEW SMOKE DETECTORS IN ELEVATOR LOBBIES AND ELEVATOR MACHINE ROOMSFOR ELEVATOR RECALL.·NEW HEAT DETECTORS IN ELEVATOR MACHINE ROOMS FOR ELEVATOR SHUNT TRIP.·NEW DUCT SMOKE DETECTOR WITH REMOTE ALARM LED INDICATOR FOR AIR HANDLER UNITS.·NEW DUCT SMOKE DETECTOR WITH REMOTE ALARM LED INDICATOR FOR COMBINATIONSMOKE/FIRE DAMPER.·NEW MANUAL PULL STATIONS AS REQUIRED BY THE CODE.·NEW CONTROL RELAYS FOR COMBINATION SMOKE/FIRE DAMPER RELEASE AND AIRHANDLER UNIT SHUTDOWN.·NEW INPUT MODULES TO MONITOR 'WATER FLOW SWITCH, VALVE TAMPER SWITCH AND POSTINDICATOR VALVE.·THIS FACILITY IS FULLY SPRINKLERED.CENTRAL STATION MONITORING FACILITY:RAPID RESPONSE MONITORING SERVICES INC400 E. RINCON,SUITE #300,CORONA, CA 92879PHONE : (800) 558-7767U.L. LISTING NUMBER: S3282-3APPLICABLE CODES AND STANDARDS2019 -California Administrative Code (CAC)Part 1, Title 24, California Code of Regulations (CCR)2019 -California Building Code (CBC)Part 2, Title 24, CCRBased on the 2018 International Building Code (IBC)2019 -California Electrical Code (CEC)Part 3, Title 24, CCRBased on the 2017 National Electrical Code (NEC)2019 -California Mechanical Code (CMC)Part 4, Title 24, CCRBased on the 2018 Uniform Mechanical Code (UMC)2019 -California Plumbing Code (CPC)Part 5, Title 24, CCRBased on the 2018 Uniform Plumbing Code (UPC)2019 -California Fire Code (CFC)Part 9, Title 24, CCRBased on the 2018 International Fire Code (IFC)NFPA No. 72. 2016 Edition, National Fire Alarm Code(With California Amendments).GENERAL NOTES1.UPON COMPLETION OF THE FIRE ALARM SYSTEM A SATISFACTORY TEST OF THE ENTIRE SYSTEMSHALL BE MADE IN THE PRESENCE OF THE LOCAL FIRE MARSHAL.2.THE FIRE ALARM SYSTEM SHALL CONFORM TO ARTICLE 760 OF THE CALIFORNIA ELECTRIC CODE.3.A MINIMUM OF 48 HOURS NOTICE SHALL BE REQUIRED FOR ANY INSPECTION AND/OR TESTING.4.A STAMPED SET OF APPROVED FIRE ALARM PLANS SHALL BE ON THE JOB SITE AND USED FORINSTALLATION. ANY DEVIATION FROM THE APPROVED PLANS, INCLUDING THE SUBSTITUTION OFDEVICES, SHALL BE APPROVED BY THE LOCAL FIRE MARSHAL.5.ALL DEVICES OF THE FIRE ALARM SYSTEM SHALL BE APPROVED AND LISTED BY THE CALIFORNIASTATE FIRE MARSHAL.6.DESIGN DRAWINGS ARE DIAGRAMMATIC. FIELD CONDITIONS SHALL BE TAKEN INTO CONSIDERATIONWHEN INSTALLING WIRE, CONDUIT AND DEVICES. ALL CHANGES FROM THE APPROVED DESIGNDRAWINGS SHALL BE DOCUMENTED AND INCLUDED ON THE RECORD DRAWINGS.7.A CERTIFICATE OF COMPLIANCE SHALL BE PREPARED BY THE INSTALLER AND GIVEN TO THE LOCALFIRE MARSHAL UPON COMPLETION OF THE INSTALLATION.8.AUDIBILITY TO BE DETERMINED PER THE REQUIREMENTS OF NFPA 72.9.THE FACILITY MUST MAINTAIN ITS REGULAR SERVICES INCLUDING ALL EXITS DURING THE TIME THEFIRE ALARM INSTALLATION IS IN PROGRESS.10.AREA SMOKE DETECTORS SHALL BE LOCATED NO CLOSER THAN 3'-0" FROM CEILING / WALLREGISTERS.11.FIRE ALARM SIGNALING CIRCUITRY SHALL BE IDENTIFIED AT TERMINAL AND JUNCTION BOXLOCATIONS.12.DUCT DETECTORS WITH SAMPLING TUBES SHALL BE SUBJECT TO AN AIR DIFFERENTIAL PRESSURETEST. DUCTS ASSOCIATED WITH PLENUM MOUNTED DUCT DETECTORS SHALL BE SUBJECT TO ANAIR VELOCITY TEST (F.B.O).13.ELEVATOR RECALL:FOR ELEVATOR #1 AND #2, THE FIRST FLOOR SHALL BE THE PRIMARY FLOOR, AND THE SECONDFLOOR SHALL BE THE ALTERNATE FLOOR.14.ALL WIRING, INITIATING DEVICES, AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THEPRINCIPAL POINT OF ANNUNCIATION (F/A PANEL TO SUPERVISE THE ANNUNCIATOR PANEL ALLCIRCUITS AND INITIATING DEVICES).15.WIRING SHALL NOT BE LOOPED THROUGH DEVICES; WIRE MUST BE CUT FOR IN AND OUT.16.POINT AND COMMON ANNUNCIATION PROHIBITED. NON-ADDRESSABLE CIRCUITS T-TAPPING ISPROHIBITED.17.ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED TO MANUFACTURERSSPECIFICATIONS.18.AUDIBILITY OF ALARM AND VOICE COMMUNICATION SHALL BE NOT LESS THAN 15 DBA ABOVEAMBIENT SOUND, BUT NOT LESS THAN 75 DBA, THROUGHOUT AREA OF ALARM.19.AREAS HAVING MORE THAN 2 STROBES IN THE FIELD OF VIEW SHALL BE SYNCHRONIZED.20.SMOKE DETECTORS AND HEAT DETECTOR LOCATIONS ARE BASED ON SMOOTH CEILING WITHMAXIMUM HEIGHT OF 10 FEET UNLESS OTHERWISE NOTED.21.STROBE LOCATION IS BASED ON 10 FOOT CEILING HEIGHT AND ARE INSTALLED ACCORDING TO NFPA72 REQUIREMENTS UNLESS OTHERWISE NOTED.22.WALL-MOUNTED STROBES SHALL HAVE THEIR BOTTOMS NOT LESS THAN 80 INCHES ABOVE FINISHEDFLOOR AND NO GREATER THAN 96 INCHES ABOVE FINISHED FLOOR.23.HANDLE OF PULL STATIONS SHALL BE MOUNTED AT 48” ABOVE FLOOR LEVEL.24.FIRE ALARM SIGNAL SHALL MEET ANSI S3.41, AUDIBLE EMERGENCY EVACUATION SIGNAL (TEMPORALPATTERN).25.THE FIRE ALARM SYSTEM SHALL IDENTIFY THE SPECIFIC INITIATING DEVICE ADDRESS, LOCATION,DEVICE TYPE, FLOOR LEVEL WHERE APPLICABLE AND STATUS INCLUDING INDICATION OF NORMAL,ALARM, TROUBLE AND SUPERVISORY STATUS, AS APPROPRIATE.SEQUENCE OF OPERATIONWIRE AND CONDUIT NOTES1.ALL NEW WIRE IS TO BE INSTALLED IN 3/4" CONDUIT UNLESS OTHERWISE NOTED.2.CONDUIT SYSTEM TO BE FURNISHED AND INSTALLED BY OTHERS.3.CONDUIT FILL SHALL BE SIZED PER C.E.C., CHAPTER 9, TABLE #4.4.THE WIRE MANUFACTURER AND MODEL NUMBERS LISTED ABOVE ARE FOR REFERENCE ONLY. AN EQUALMODEL FROM ANOTHER MANUFACTURER SHALL BE ACCEPTABLE.5.ALL WIRING SHALL BE INSTALLED IN ACCORDANCE WITH C.E.C. ARTICLE 760, POWER LIMITED FIRE ALARMCIRCUITS.6.SIGNALING LINE CIRCUITS (SLCs) SHALL BE CLASS B.NOTIFICATION APPLIANCE CIRCUITS (NACs) SHALL BE CLASS B.600SINGLE CONDUCTORTFN#18 AWG.0783"VOLTS# OF COND.TYPESIZENOM. O.D. (in.)MANUFACTURER #TWO CONDUCTOR300#16 AWG.164"USETWISTEDNETWORKWEST PENN #60991B FPLPOR EQUAL600SINGLE CONDUCTORTHHN#14 AWG.101"600SINGLE CONDUCTORTHHN#12 AWG.120"ENCORE WIRE #TFNOR EQUALSLCENCORE WIRE #THHNOR EQUALNACENCORE WIRE #THHNOR EQUAL120VacABCD0.622"1/2"TRADESIZE3/4"1"1-1/4"1-1/2"2"2-1/2"NOMINAL INTERNALDIAMETER (in.)0.824"1.049"1.380"1.610"2.067"2.731"TOTAL AREA100%0.304 IN. SQ.0.533 IN. SQ.0.864 IN. SQ.1.496 IN. SQ.2.036 IN. SQ.3.356 IN. SQ.5.858 IN. SQ.ALLOWABLE FILLOVER 2 WIRES 40%0.122 IN. SQ.0.213 IN. SQ.0.346 IN. SQ.0.598 IN. SQ.0.814 IN. SQ.1.342 IN. SQ.2.343 IN. SQ.ELECTRICAL METALLIC TUBING (EMT)#18 AWGTFNTYPETRADE SIZE1/2"22MAXIMUM NUMBER OR CONDUCTORS IN ELECTRICAL METALLIC TUBING (EMT)C.E.C., CHAPTER 9, TABLE #4C.E.C., INFORMATIVE ANNEX C, TABLE #C.1CONDUCTOR SIZE3/4"381"631-1/4"1081-1/2"1482"244#14 AWGTHHN12223561841382-1/2"---241#12 AWGTHHN916264561101176NEC WIRE TYPE:FPLP-POWER-LIMITED FIRE PROTECTIVE SIGNALING CIRCUIT CABLE - PLENUM RATED.TFN-HEAT-RESISTANT THERMO-PLASTIC COVERED WIRE - SOLID - IN CONDUIT.THHN-HEAT-RESISTANT THERMO-PLASTIC COVERED WIRE - SOLID - IN CONDUIT.UNSHEILDEDATTIC SPACECEILINGFLOORFINISHEDNOTE: DETAIL PROVIDED FOR SMOOTH CEILINGS UP TO 10'-0" IN HEIGHT. FOR ALL OTHER APPLICATIONS REFERENCE 2019, NFPA 72.REMOTEDISCON -NECTDRILL SIGNALSILENCE ACK/PANE LSILENCE RESETFIRE ALARMSUPAC POWERTROUBLE DISA BLEMONITOR TESTSERV ICE DETECTORGROUNDFAULT0#*,8TUV 9WXYZ7PQRS5JKL 6MNO4GHI 2ABC 3DEF1 ANNUNCIATOR DISPLAY80 CHARACTERSPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARE72" A.F.F.PULL STATION5'-0" MAX.BACK BOX:STANDARD 4"SQUARE, DEEP, BOXWITH SINGLE GANGRING OR SINGLEGANG, DEEP, BOX,VERTICAL.EXIT@ 48"O.C.A.F.F.FLUSH MOUNT TOCEILING USING ASTANDARD 4" SQUAREBOX W/3-O PLASTERRING.36" MIN.SMOKEDETECTORSRETURN/SUPPLYOPENINGSMOKETYPICAL DEVICE MOUNTING DETAILDOCUMENTSSYSTEM RECORDMOUNT DOCUMENTCABINET ADJACENTTO FIRE ALARMCONTROL PANEL60" A.F.F.DIALER60" A.F.F.CELLULAR ALARMCOMMUNICATORFIELD VERIFYiO10002000 CFMGREATER THANAIR HANDLER UNITREQUIRED TO SHUT DOWN AIR HANDLER UNITSGREATER THAN 2,000 CFM. DUCT DETECTORSTO BE INSTALLED ON SUPPLY SIDE OF AIRHANDLER UNIT. MOUNT ON SIDE OF DUCT.DUCT DETECTORFLUSH MOUNT TOCEILING USING ASTANDARD SINGLEGANG BOX, DEEP.REMOTE LEDHORN/STROBEBACK BOX:VISUAL - AUDIO/ VISUAL -SINGLE GANG,DEEP, BOX,VERTICAL80"A.F.F.MIN. TOBOTTOMOFSTROBELENS96"A.F.F.MAX. TOTOP OFSTROBELENSPowerFire A la rmSuperviso ryGround FaultTroub leControls Enab ledAck/SilenceLamp TestRLCD-C - FIREALARMREMOTEANNUNCIATOR'ANN'.66" A.F.F.HORN/STROBEBACK BOX:HORN STROBE - MOUNT TO449 WEATHERPROOF BACKBOXSTROBE24" MAX.ELEVATOR MACHINEROOM SPRINKLER HEADSURFACE MOUNT USINGA STANDARD 4" SQUAREDEEP BOX.HEATANNUNCIATE AT FIRE ALARMCONTROL PANEL(TROUBLE & ALARM)ANNUNCIATE AT OFF SITECENTRAL STATION(TROUBLE & ALARM)ACTIVATE AUDIBLE ANDVISUAL ALARM SIGNALSCLOSE RELATED SMOKE/FIREDAMPERSELEV. LOBBY SMOKEDETECTORSYSTEMRESPONSEDEVICEYESRECALL ALL ELEVATORSSERVING FLOOR OF ALARMNOYESNONOYESNOYESYESYESYESNOYESNONONONONOMANUAL PULLSTATIONAREA SMOKEDETECTORSDUCT SMOKEDETECTORELEVATOR SHAFTSMOKE/HEATDETECTORSPRINKLERWATERFLOW SWITCHSPRINKLER VALVETAMPER SWITCHBUILDING POWERFAILUREYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESYESSHUT DOWN RELATED AIRHANDLING(HVAC)NONOYESNOANNUNCIATE AT ALL REMOTEANNUNCIATORS(TROUBLE & ALARM)YESYESYESYESYESYESYESYESNONONONONONO(SUPERVISORY)(SUPERVISORY)(SUPERVISORY)NONONOPOST INDICATORVALVEYESYESNOYESNONONOCELLULARCOMMUNICATORYESYESYESNONONONONONEMA 3WEATHER ENCLOSUREIF EXPOSED TOTHE ELEMENTS.5'-0" MAX(INSIDE DUCT)DUCT DETECTORCOMBINATION SMOKEFIRE DAMPERMOUNT ON TOP ORSIDE OF DUCT.NEVER MOUNT ONBOTTOM OF DUCT.HORN/STROBESTROBE100'-0" MAX.IN CORRIDOR15'-0" MAX.TO END OFCORRIDORBACK BOX:AUDIO/VISUAL - STANDARD 4"SQUARE BOX, 2-1/8" DEEP.HORN/STROBEFIRE ALARM SYMBOLLEGEND, SEQUENCEOF OPERATION,NOTES AND DETAILFA-13CONTROL RELAY MODULEEDWARDS #SIGA-CR7300-1657:0121SINGLE GANG, 2-1/2" DEEP, BOX----------------------- 3535SystemsWhen Reliability CountsN I C E TCERTIFIEDNICET certificationWe support and encourageFILE #S36741Professional Stamp:Agency Stamp:Project Name:REVISION / ISSUENO.DATEThese drawings and specifications are the property and copyright of TRLSystems, Inc. and shall not be used on any other work except by writtenagreement with TRL Systems, Inc. All Rights Reserved.Date:COPYRIGHT - 2023CScale:TRL Proj. #OfSheetsSheet Number:Drawn By:Sheet Title:Facility:Tel: 800.266.1392909.390.8392Fax: 909.390.8397www.trlsystems.comEmail: info@trlsystems.comLic. #: C10/C16 - 413747Rancho Cucamonga - Corporate Headquarters:9531 Milliken Avenue, Rancho Cucamonga, CA 91730Burbank - Regional Office:695 South Glenwood Place, Burbank, CA 91506Tustin - Regional Office:1451 Edinger Avenue, Suite #A, Tustin, CA 92780San Diego - Regional Office:9155 Brown Deer Road, Suite #7, San Diego, CA 92121Y.L./I.L.13852AS NOTED03.24.230546805 DUNE PALMS RD. LA QUINTA, CA 92253 MSD WELBEHEALTH LA QUINTA PACE CENTER FIRE ALARM SYSTEM INSTALLATION EXP. 11/30/2023NO. 413747CALIFORN IA DRAOBENECILETATSRO T CARTNOC STATEOFSC TRL S Y S TEMS, INCORPORATED ELECTRICAL C10/ C 16 04.18.23CITYREVISIONY.L.06.08.23AS BUILTY.L.SPECIFIC NOTESTO SPARE 120 Vac CIRCUIT AT EXISTING ELECTRICAL PANEL. FIELD VERIFY PANEL LOCATIONAND CIRCUIT NUMBER.TIE NEW INITIATING DEVICES TO NEW ADDRESSABLE LOOP AT NEW FIRE ALARM CONTROLPANEL 'FACP'. EXTEND WIRE AS NECESSARY FOR PROPER OPERATION.TIE NEW VISUAL AND AUDIO/VISUAL DEVICES TO NEW SPARE NOTIFICATION APPLIANCECIRCUIT AT NEW FIRE ALARM CONTROL PANEL 'FACP'. EXTEND WIRE AS NECESSARY FORPROPER OPERATION.NEW CONTROL RELAY PROVIDED FOR COMBINATION SMOKE/FIRE DAMPER RELEASE UPONTHE RELATED DUCT DETECTOR ACTIVATION.NEW CONTROL RELAY PROVIDED FOR THE AIR HANDLER UNIT SHUTDOWN UPON THERELATED DUCT DETECTOR ACTIVATION.NEW HEAT DETECTOR PROVIDED IN ELEVATOR MACHINE ROOM (FIELD VERIFY ROOMLOCATION) TO BE MOUNTED WITHIN 2'-0" OF EACH SPRINKLER HEAD FOR THE ELEVATOR'SHUNT-TRIP' EXTEND WIRE AS NECESSARY FOR PROPER OPERATION.NOTES:·ALL DEVICES DESIGNATED WITH 'E' ARE EXISTING DEVICES TO REMAIN.·ALL DEVICES NOT DESIGNATED WITH 'E' ARE NEW DEVICES TO BE INSTALLED.CABLE LEGENDFIRST FLOOR PLAN1/8"=1'-0"NORTHN1/8"=1'-0"NORTHNSECOND AND FIRST FLOOR ROOF FLOOR PLANNOTE: ALL WIRE TO BE RUN IN 3/4" CONDUIT (FURNISHED AND INSTALLED BY OTHERS)UNLESS OTHERWISE NOTED.NEW CONDUIT600SINGLE CONDUCTORTFN#18 AWG.0783"VOLTS# OF COND.TYPESIZENOM. O.D. (in.)MANUFACTURER #TWO CONDUCTOR300#16 AWG.164"USETWISTEDNETWORKWEST PENN #60991B FPLPOR EQUAL600SINGLE CONDUCTORTHHN#14 AWG.101"600SINGLE CONDUCTORTHHN#12 AWG.120"ENCORE WIRE #TFNOR EQUALSLCENCORE WIRE #THHNOR EQUALNACENCORE WIRE #THHNOR EQUAL120VacABCDUNSHEILDEDFIRST FLOORSECOND AND FIRST FLOOR ROOF FLOORRISER DIAGRAMFIRST & SECOND AND FIRSTFLOOR ROOF FLOOR PLANSAND RISER DIAGRAMFA-2ER75PIVASDCT115151101575151575753035351103011015153015151515151511015153030151515757515307515151515301511030CT2VSWFEEEPPRI.ALT.HATSHUNTRRERRRRRASDRR1515151515751515PASDPRRPERPPPRR1515 SystemsWhen Reliability CountsN I C E TCERTIFIEDNICET certificationWe support and encourageFILE #S36741Professional Stamp:Agency Stamp:Project Name:REVISION / ISSUENO.DATEThese drawings and specifications are the property and copyright of TRLSystems, Inc. and shall not be used on any other work except by writtenagreement with TRL Systems, Inc. All Rights Reserved.Date:COPYRIGHT - 2023CScale:TRL Proj. #OfSheetsSheet Number:Drawn By:Sheet Title:Facility:Tel: 800.266.1392909.390.8392Fax: 909.390.8397www.trlsystems.comEmail: info@trlsystems.comLic. #: C10/C16 - 413747Rancho Cucamonga - Corporate Headquarters:9531 Milliken Avenue, Rancho Cucamonga, CA 91730Burbank - Regional Office:695 South Glenwood Place, Burbank, CA 91506Tustin - Regional Office:1451 Edinger Avenue, Suite #A, Tustin, CA 92780San Diego - Regional Office:9155 Brown Deer Road, Suite #7, San Diego, CA 92121Y.L./I.L.13852AS NOTED03.24.230546805 DUNE PALMS RD. LA QUINTA, CA 92253 MSD WELBEHEALTH LA QUINTA PACE CENTER FIRE ALARM SYSTEM INSTALLATION EXP. 11/30/2023NO. 413747CALI FORN IA DRAOBENECILETATSRO T CARTNOC STATEOFSC TRL S Y S TEMS, INCORPORATED ELECTRICAL C10 / C 16 04.18.23CITYREVISIONY.L.06.08.23AS BUILTY.L.VOLTAGE DROP CALCULATIONNEW 'FACP' BATTERY CALCULATIONTOTAL0.2590STANDBY0.1720BATTERY CALCULATIONiO1000 BASE PANELEXTERNAL DEVICESDEVICEFIRE ALARM CONTROL PANEL 'FACP'TOTALSQUANT.1STANDBY0.1720TOTALALARM0.4990ALARM0.26700.2670CONTROL RELAYS (SIGA-CR)SIGA SMOKE DETECTORS (SIGA-OSD)0.0039020.0004160.00075TOTALS0.0000320.00007513100.0000450.0000752.4167050.000750.0005850.0004MODULES (SIGA-270,CT1)0.002250.0002590.00360.0990RLCD-CANNUNCIATOR10.09900.11500.1150TOTAL BATTERY IS BASED ON 20% SPARE CAPACITYBATTERY PROVIDED8.6856480.2525592-12V @10.7258484AMP-HRAMP-HRAMP-HR18.0 A.H.24 HOURS STANDBY =5 MINUTES ALARM =8.938207AMP-HRTOTAL BATTERY =+ 20% SPARE CAPACITY =0.0990TOTALS0.1150REMOTE ALARM LED (SIGA-LED)0.002030.00000.00000.0060RIBU1C RELAYS0.000080.00000.00000.0000**NOT SUPPORTED BY MONITORING SYSTEM**0.00068MODULES (SIGA-CT2)0.0003960.00039610.000680.0460TELGUARD #TG7LVF01 & #TG-PEM - DIALER10.04600.13200.13200.0410SA-DACT10.04100.10000.1000WALL MOUNT LED HORN/STROBE WP WALL MOUNT HORN/STROBE 35cd0.0500160.00000.00000.80000.238020.00000.00000.4760WALL MOUNT LED STROBE 0.0280360.00000.00001.0080CEILING MOUNT LED HORN/STROBE 0.060020.00000.00000.1200SIGA HEAT DETECTORS (SIGA-HRD)0.0000900.00004520.0000450.000090GENESIS OUTDOOR HORN/STROBE: WG4BackplateOptional trim skirtWG4Gasket2-GANG(SURFACE MOUNT)WEATHERPROOFELECTRICAL BOX (449)Front coverSignal Out -Signal Out +Signal In -Signal In +9000756 XX Wire slotPULLHERETOREMOVECandellasetting switch(S2)Horn patternjumper (JP1)Strobe patternjumper (JP4)Horn volumejumper (JP3)GENESIS OUTDOOR HORN/STROBE: WG4CDOUBLE GANGELECTRICAL BOXTRIM PLATE(OPTIONAL)MOUNTINGPLATEMACHINESCREWSHORTINGCLIPSIGNALINGAPPLIANCEGENESIS WALL MOUNT: G4 SERIESGENESIS LED: GC STROBE+-STROBE CIRCUITIN (SIGNALPOLARITY SHOWNIN THE ACTIVECONDITION)+-STROBECIRCUITOUTSHORTINGCLIPGENESIS CEILING MOUNT: GC SERIESELECTRICALBOXWIRING PLATE(REQUIRED, ORDEREDSEPARATELY)MACHINE SCREW(2X, SUPPLIED WITHWIRING PLATE)GC SIGNALINGAPPLIANCETRIM PLATE(OPTIONAL)MODULEALARMSIGA-CR/SIGA-CT1/SIGA-CT2: MOUNTINGMOUNT EST SIGA SERIES MODULESSIGA-CT1, SIGA-CT2, SIGA-CR, TOSTANDARD SINGLE GANG 2-1/2" DEEPELECTRICAL BOX. THE TERMINALS WILLACCEPT #14AWG WIRE.SINGLE GANG,2-1/2" DEEPELECTRICAL BOXWALL PLATE, WHITE(1 GANG)SIGA-CR: ELEVATOR INTERFACEHSIGA-CR: 120 VAC FAN SHUTDOWN CIRCUIT4321867N.O.C.N.C.DATA IN (+)DATA IN (-)DATA OUT (+)DATA OUT (-)SIGA-CRCONTROL RELAYRIBU1C RELAYAUTOBASAOHMSOL120 VACN/ANSIGA-CR: 120 VAC DAMPER CIRCUIT CONTROLH4321867N.O.C.N.C.DATA IN (+)DATA IN (-)DATA OUT (+)DATA OUT (-)SIGA-CRCONTROL RELAYRIBU1C RELAYNH120 VACNHN120 VACPOWER TONEXTDAMPERCSFDCSFD4321867N.O.C.N.C.DATA IN (+)DATA IN (-)DATA OUT (+)DATA OUT (-)SIGA-CRCONTROL RELAYN.C.COMMONN.O.PRIMARYELEVATORRECALL4321867N.O.C.N.C.SIGA-CRCONTROL RELAYN.C.COMMONN.O.ALTERNATEELEVATORRECALLUTIIIZE N.C. CONTACTS IFPOSSIBLE TO OBTAINFAIL-SAFE WIRING.4321867N.O.C.N.C.SIGA-CRCONTROL RELAYN.C.COMMONN.O.ELEVATORVISUALWARNING (HAT)UTIIIZE N.C. CONTACTS IFPOSSIBLE TO OBTAINFAIL-SAFE WIRING.UTIIIZE N.C. CONTACTS IFPOSSIBLE TO OBTAINFAIL-SAFE WIRING.ELEVATOR SHUNT TRIP784312DATA OUT (+)DATA OUT (-)SIGA-CT1SINGLE INPUT MODULERIBU1C RELAYEND OF LINE4321867N.O.C.N.C.SIGA-CRCONTROL RELAYRIBU1C RELAYELEVATORSHUNT TRIPDISCONNECTINGMEANSNHNH120 VACPOWERCIRCUITDATA IN (+)DATA IN (-)DATA IN (+)SIGA-CT2: DUAL INPUT MODULE4321CAT. NO. SIGA-CT2876547KINPUT 1CONTACTINPUT 2CONTACTSTATUS/ALARMSTATUS/ALARM0.5 Amp @ 120VAC2.0 Amp @ 24VDCCONTACT RATING:DATA IN (-)DATA OUT (+)DATA OUT (-)DUAL INPUT MODULEEOLR47KEOLR784312SIGA-CT1: INPUT MODULEDATA IN (+)CAT. NO. SIGA-CT147KINPUT 1CONTACTSTATUS/ALARMDATA IN (-)DATA OUT (+)DATA OUT (-)SINGLE INPUT MODULEEOLRSYSTEM CALCULATIONS,WIRING DIAGRAMSANDMOUNTING DETAILSFA-3396FIRST FLOOR - FACP24#14A/V-0-1WORST CASE HARD WIRE VOLTAGE DROP CALCULATIONPOWER SOURCE:SIGNAL CIRCUIT:WIRE GAUGE (AWG):DISTANCE IN FEET:PS OUTPUT VOLTAGE:20.485% OF PS VOLTAGE:3.14OHM / kFT:CLASS BCIRCUIT TYPE:NOMINAL DEVICE INPUT VOLTAGE:MINIMUM DEVICE INPUT VOLTAGE:24 Vdc16 Vdc20.47680.22460.300TOTALS:171.060DEVICETYPEQUANTITYDEVICECURRENT (mA)TOTAL DEVICECURRENT (mA)792(DISTANCE IN FEET * 2) * (OHM/kFT / 1000) = CIRCUIT RESISTANCE0.00314*=2.48785% OF PS VOLTAGE - ( TOTAL DEVICE CURRENT * CIRCUIT RESISTANCE ) = END OF LINE VOLTAGE20.4-(*)=1.0602.48717.76WP HORN-STROBE 35cd (WP)0.238WALL STROBE 15,30,75 & 110cd0.028WALL HORN-STROBE 15,30,75 & 110cd0.05010.060CEILING HORN-STROBE 15,30,75 & 115cd0.060 SystemsWhen Reliability CountsN I C E TCERTIFIEDNICET certificationWe support and encourageFILE #S36741Professional Stamp:Agency Stamp:Project Name:REVISION / ISSUENO.DATEThese drawings and specifications are the property and copyright of TRLSystems, Inc. and shall not be used on any other work except by writtenagreement with TRL Systems, Inc. All Rights Reserved.Date:COPYRIGHT - 2023CScale:TRL Proj. #OfSheetsSheet Number:Drawn By:Sheet Title:Facility:Tel: 800.266.1392909.390.8392Fax: 909.390.8397www.trlsystems.comEmail: info@trlsystems.comLic. #: C10/C16 - 413747Rancho Cucamonga - Corporate Headquarters:9531 Milliken Avenue, Rancho Cucamonga, CA 91730Burbank - Regional Office:695 South Glenwood Place, Burbank, CA 91506Tustin - Regional Office:1451 Edinger Avenue, Suite #A, Tustin, CA 92780San Diego - Regional Office:9155 Brown Deer Road, Suite #7, San Diego, CA 92121Y.L./I.L.13852AS NOTED03.24.230546805 DUNE PALMS RD. LA QUINTA, CA 92253 MSD WELBEHEALTH LA QUINTA PACE CENTER FIRE ALARM SYSTEM INSTALLATION EXP. 11/30/2023NO. 413747CALIFORN IA DRAOBENECILETATSRO T CARTNOC STATEOFSC TRL S Y S TEMS, INCORPORATED ELECTRICAL C10 / C 16 04.18.23CITYREVISIONY.L.06.08.23AS BUILTY.L.L IFT N O R M A L A L A R M E P U L L I N C A S E O F F I R E F I R E BLANK COVER PLATECONTROL RELAY MODULEBLANK COVER PLATE &REMOTE LED SIGA-LEDSIGA-CR412378SIGA-270: MANUAL PULL STATIONCAT. NO. SIGA-270FIRE ALARM STATIONDATA IN (+)DATA IN (-)DATA OUT (+)DATA OUT (-)6543 271DATA IN (+)DATA IN (-)DATA OUT (+)DATA OUT (-)CAT. NO. SIGA-SBSTANDARD BASESIGA-SB(4): STANDARD BASETERMDESCRIPTION1NOT USED2DATA IN/OUT (+)3NOT USED4DATA IN (-)5NOT USED6NOT USED7DATA OUT (-)COVERRELEASESCREWSIGA-270: MOUNTINGBACKPLATESINGLE GANG DEEPELECTRICAL BOXTOGGLESWITCHGLASS RODRELEASELEVERSIGA-DMP: DUCT MOUNTING PLATEBASECOMPATIBLEDETECTORCOMPATIBLESIGA-SB(4)/SIGA-LED: REMOTE LED6543 271DATA IN (+)DATA IN (-)DATA OUT (+)DATA OUT (-)CAT. NO. SIGA-SBSTANDARD BASETERMDESCRIPTION1NOT USED2DATA IN/OUT (+)3NOT USED4DATA IN (-)4REMOTE LED5REMOTE LED6NOT USED7DATA OUT (-)-SIGA-LED+SMOKE/HEAT DETECTOR: MOUNTING123DETECTOR MOUNT BASE TO 4" SQUARESTANDARD ELECTRICAL BOX 1-1/2" DEEP(SIGA-SB4/RB4)STANDARD ELECTRICAL BOX 2-1/8" DEEP.(SIGA-AB4G)1. TAMPER-RESIST LEVER ARM ON BASE(BREAK OFF TO DISABLE).2.ACCESS SLOT FOR TAMPER-RESISTMECHANISM.3.LED INDICATOR.CEILING LINESIGA-SB4/RB4BASESIGA-XXSDETECTORSTANDARD 4"SQUARE DEEPBOX WITH 3-0PLASTER RINGDO NOT PAINTDO NOT PAINTGASKET(PREASSEMBLED)DUCT HOUSINGCOVERSMOKECHAMBER TOPCOMPATIBLESMOKE DETECTORSMOKE CHAMBER BOTTOM(PREASSEMBLED)DUCT HOUSINGBOXCOUPLINGSAMPLING TUBE(ORDERED SEPARATELY)RUBBERSTOPPEREXHAUSTTUBE#4 x 3/8 SCREW (4X)DUCT HOUSINGBOXSMOKE CHAMBER BOTTOM(PREASSEMBLED)SIGA-SDH: DUCT DETECTOR MOUNTINGREMOTE LED – REMOTE LED + SLC + IN/OUT SLC – IN / SLC – OUTDATA IN (+)DATA IN (-)DATA OUT (+)DATA OUT (-)SIGA-SDH: DUCT DETECTOR WIRINGWIRING DIAGRAMSANDMOUNTING DETAILSFA-4DIP SwitchPowerFire AlarmSupervisoryGround FaultTroubleControls EnabledAck/SilenceLamp TestABCDEFV(+)V(-)N/C(+)(-)OUTExpander CableTerminalsRemoteKeyswitchTerminals24 (-) OUT24 (+) OUT24 (-) IN24 (+) INCH2 (-) OUTCH2 (+) OUTCH2 (-) INCH2 (+) INCH1 (-) OUTCH1 (+) OUTCH1 (-) INCH1 (+) INRXTXFIRE ALARM REMOTE ANNUNCIATOR TYPICAL 'ANN' DETAIL Scale: 1:2WIRING DETAILRLCD-C-+IN FROM FIRE ALARMCONTROL PANEL (RS485)-+IN FROM FIRE ALARMCONTROL PANEL (24Vdc)-+-+OUT TO NEXT REMOTEANNUNCIATOR (RS485)OUT TO NEXT REMOTEANNUNCIATOR (24Vdc)RLCD-C: REMOTE ANNUNCIATORResetSignal SilenceDrill15.75"28.00"USE THIS EXAMPLE FOR 'FACP'FACE MOUNT TO WALL MONITORING PANELCENTRAL STATIONTO WALL STUDS (MIN.3)PER POWER-STRUTMETAL SCREWS(3)-#10x1-1/2"(TOTAL 4)PANEL TO EACH POWER-STRUT1/4" FENDER WASHERS PER(2) 1/4x20 x 3/4" BOLTS W/AT 16" O.C. (TYP.)(18 GAUGE)AMS 20HDS400 STUD WALL/PANEL ELEVATION TO MINIMUM 3 STUDS).(EXTEND / CONNECT1-5/8" x 1" (TYP. OF 2)POWER-STRUT #PS400(APPX. WT. 30lbs.)CONTROL PANELFIRE ALARM5/8" GYP. BOARD5/8" GYP. BOARD SECTION AT PANEL TO MINIMUM 3 STUDS).(EXTEND / CONNECT1-5/8" x 1" (TYP. OF 2)POWER-STRUT #PS400SCREWS PER POWER-STRUT(3) #10 x 1-1/2" METALTO WALL STUD (MIN.3).(18 GAUGE)AMS 20HDS400 STUDAT 16" O.C.NOTE:APPROXIMATE WEIGHT OF FULLY ASSEMBLEDFIRE ALARM PANEL:'FACP' > 20lbsNO OTHER EQUIPMENT EXCEEDS 20lbs.iO10003.86"iO1000: SURFACE MOUNT PANEL ANCHORAGEPANEL MAY BE MOUNTEDANYWHERE IN THIS RANGE WITHIN3" FROM END OF POWER-STRUTNOT USEDNOT USEDNOT USEDNOT USED REMOTEDISCON-NECTDRILLSIGNALSILENCEACK/PANELSILENCERESETFIRE ALARMSUPAC POWERTROUBLEDISABLEMONITORTESTSERVICEDETECTORGROUNDFAULT0#*,8TUV9WXYZ7PQRS5JKL6MNO4GHI2ABC3DEF1EARTHXFMRINBATTERY+-+-BASLC1+-+-BASLC2+-+-CH1CH2ANN+BSLC1-+-A+-NAC2+-NAC1+-NAC4+-NAC3+-SA-DACTDUAL LINE DIALERJ1J4LINE 1LINE 2SA-232SERIAL PORT(RS-232)OUT TOSYSTEMPRINTER.GNDRTSTXDRXDNGL120VacTRANSFORMERANNUNCIATOR DISPLAY80 CHARACTERNOTRB CNCNOSUP CNCALM CNOCONTINUOUS (+)COM (-)CONTINUOUS (+)COMMONTROUBLERELAYCOMMONSUPERVISORYRELAYCOMMONALARMRELAYCONTINUOUSAUXILIARYPOWER+-OUT TO REMOTEANNUNCIATOR(S) (RS485).8 MAX.OUT TO REMOTEANNUNCIATOR(S) (24Vdc).8 MAX.+-OUT TO FIELDADDRESSABLEDEVICES.+-BATTERY12V, 18AH+DATE OF INSTALLATION:_____________-BATTERY12V, 18AH+DATE OF INSTALLATION:_____________-REMOTEDISCON-NECTDRILLSIGNALSILENCEACK/PANELSILENCERESETFIRE ALARMSUPAC POWERTROUBLEDISABLEMONITORTESTSERVICEDETECTORGROUNDFAULT0#*,8TUV9WXYZ7PQRS5JKL6MNO4GHI2ABC3DEF1ANNUNCIATOR DISPLAY80 CHARACTERSPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPAREFIRE ALARM CONTROL PANEL 'FACP' 'FACP' DETAIL Scale: 1:2WIRING DETAILiO1000OUT TOEXISTINGPHONELINETO EXISTING 120VacEMERGENCY POWER CIRCUITZONE INPUTSREMOTEANTENNA784312DATA IN (+)CAT. NO. SIGA-CT1DATA IN (-)DATA OUT (+)DATA OUT (-)SINGLE INPUT MODULE1212345612312EARTHGROUNDTRIPINPUTSTC1(N.O.)STC2(N.C.)RTSIMTELGUARDDigital TG-712345678Power LEDNot UsedNot UsedSystem StatusLEDsLED ModeToggle ButtonDCGNDDCGNDTG-PEMNOTIFICATION APPLIANCE CIRCUIT (NAC) A/V-0-115 K EOLNOTIFICATION APPLIANCE CIRCUIT (NAC) A/V-0-215 K EOL SystemsWhen Reliability CountsN I C E TCERTIFIEDNICET certificationWe support and encourageFILE #S36741Professional Stamp:Agency Stamp:Project Name:REVISION / ISSUENO.DATEThese drawings and specifications are the property and copyright of TRLSystems, Inc. and shall not be used on any other work except by writtenagreement with TRL Systems, Inc. All Rights Reserved.Date:COPYRIGHT - 2023CScale:TRL Proj. #OfSheetsSheet Number:Drawn By:Sheet Title:Facility:Tel: 800.266.1392909.390.8392Fax: 909.390.8397www.trlsystems.comEmail: info@trlsystems.comLic. #: C10/C16 - 413747Rancho Cucamonga - Corporate Headquarters:9531 Milliken Avenue, Rancho Cucamonga, CA 91730Burbank - Regional Office:695 South Glenwood Place, Burbank, CA 91506Tustin - Regional Office:1451 Edinger Avenue, Suite #A, Tustin, CA 92780San Diego - Regional Office:9155 Brown Deer Road, Suite #7, San Diego, CA 92121Y.L./I.L.13852AS NOTED03.24.230546805 DUNE PALMS RD. LA QUINTA, CA 92253 MSD WELBEHEALTH LA QUINTA PACE CENTER FIRE ALARM SYSTEM INSTALLATION EXP. 11/30/2023NO. 413747CALI FORN IA DRAOBENECILETATSRO T CARTNOC STATEOFSC TRL S Y S TEMS, INCORPORATED ELECTRICAL C10 / C 16 04.18.23CITYREVISIONY.L.06.08.23AS BUILTY.L.NOTIFICATION APPLIANCE CIRCUIT (NAC) A/V-0-315 K EOL FIRE ALARMCONTROL PANELWIRING DIAGRAMSFA-5NEW FIRE ALARM CONTROL PANEL 'FACP' WIRING DIAGRAM 3535SystemsWhen Reliability CountsN I C E TCERTIFIEDNICET certificationWe support and encourageFILE #S36741Professional Stamp:Agency Stamp:Project Name:REVISION / ISSUENO.DATEThese drawings and specifications are the property and copyright of TRLSystems, Inc. and shall not be used on any other work except by writtenagreement with TRL Systems, Inc. All Rights Reserved.Date:COPYRIGHT - 2023CScale:TRL Proj. #OfSheetsSheet Number:Drawn By:Sheet Title:Facility:Tel: 800.266.1392909.390.8392Fax: 909.390.8397www.trlsystems.comEmail: info@trlsystems.comLic. #: C10/C16 - 413747Rancho Cucamonga - Corporate Headquarters:9531 Milliken Avenue, Rancho Cucamonga, CA 91730Burbank - Regional Office:695 South Glenwood Place, Burbank, CA 91506Tustin - Regional Office:1451 Edinger Avenue, Suite #A, Tustin, CA 92780San Diego - Regional Office:9155 Brown Deer Road, Suite #7, San Diego, CA 92121Y.L./I.L.13852AS NOTED03.24.230546805 DUNE PALMS RD. LA QUINTA, CA 92253 MSD WELBEHEALTH LA QUINTA PACE CENTER FIRE ALARM SYSTEM INSTALLATION EXP. 11/30/2023NO. 413747CALI FORN IA DRAOBENECILETATSRO T CARTNOC STATEOFSC TRL S Y S TEMS, INCORPORATED ELECTRICAL C10 / C 16 04.18.23CITYREVISIONY.L.SPECIFIC NOTESTO SPARE 120 Vac CIRCUIT AT EXISTING ELECTRICAL PANEL. FIELD VERIFY PANEL LOCATIONAND CIRCUIT NUMBER.TIE NEW INITIATING DEVICES TO NEW ADDRESSABLE LOOP AT NEW FIRE ALARM CONTROLPANEL 'FACP'. EXTEND WIRE AS NECESSARY FOR PROPER OPERATION.TIE NEW VISUAL AND AUDIO/VISUAL DEVICES TO NEW SPARE NOTIFICATION APPLIANCECIRCUIT AT NEW FIRE ALARM CONTROL PANEL 'FACP'. EXTEND WIRE AS NECESSARY FORPROPER OPERATION.NEW CONTROL RELAY PROVIDED FOR COMBINATION SMOKE/FIRE DAMPER RELEASE UPONTHE RELATED DUCT DETECTOR ACTIVATION.NEW CONTROL RELAY PROVIDED FOR THE AIR HANDLER UNIT SHUTDOWN UPON THERELATED DUCT DETECTOR ACTIVATION.NEW HEAT DETECTOR PROVIDED IN ELEVATOR MACHINE ROOM (FIELD VERIFY ROOMLOCATION) TO BE MOUNTED WITHIN 2'-0" OF EACH SPRINKLER HEAD FOR THE ELEVATOR'SHUNT-TRIP' EXTEND WIRE AS NECESSARY FOR PROPER OPERATION.NOTES:·ALL DEVICES DESIGNATED WITH 'E' ARE EXISTING DEVICES TO REMAIN.·ALL DEVICES NOT DESIGNATED WITH 'E' ARE NEW DEVICES TO BE INSTALLED.CABLE LEGENDFIRST FLOOR PLAN1/8"=1'-0"NORTHN1/8"=1'-0"NORTHNSECOND AND FIRST FLOOR ROOF FLOOR PLANNOTE: ALL WIRE TO BE RUN IN 3/4" CONDUIT (FURNISHED AND INSTALLED BY OTHERS)UNLESS OTHERWISE NOTED.NEW CONDUIT600SINGLE CONDUCTORTFN#18 AWG.0783"VOLTS# OF COND.TYPESIZENOM. O.D. (in.)MANUFACTURER #TWO CONDUCTOR300#16 AWG.164"USETWISTEDNETWORKWEST PENN #60991B FPLPOR EQUAL600SINGLE CONDUCTORTHHN#14 AWG.101"600SINGLE CONDUCTORTHHN#12 AWG.120"ENCORE WIRE #TFNOR EQUALSLCENCORE WIRE #THHNOR EQUALNACENCORE WIRE #THHNOR EQUAL120VacABCDUNSHEILDEDFIRST FLOORSECOND AND FIRST FLOOR ROOF FLOORRISER DIAGRAMFIRST & SECOND AND FIRSTFLOOR ROOF FLOOR PLANSAND RISER DIAGRAMFA-2ER115PIVASDCT1151511015751515757530353511030110151530151515151515110151530301515151575751530151515151530151530CT2VSWFEEEPPRI.ALT.HATSHUNTRRERRRRRASDRR151515151515751515PASDPRRPERPPPRR NFPA 72, Fig. 4.5.2.1 (p. 1 of 6) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. Protected Property Information Name of property: MSD Welbehealth La Quinta Pace Center Permit# 23-0001 Address: 46805 Dune Palms Road La Quinta, Ca.92253 Description of property: Healthcare Facility Occupancy type: I-4/B Name of property representative: Hondo Shaver Address: 46805 Dune Palms Road La Quinta, Ca.92253 Phone: 703.283.8327 Fax: E-mail: hondo.shaver@welbehealth.com Authority having jurisdiction over this property: Riverside County Fire Phone: Fax: E-mail: 2. Fire Alarm System Installation, Service, and Testing Information Installation contractor for this equipment: TRL Systems Address: 9531 MILLIKEN AVENUE Phone: 800-266-1392 Fax: E-mail: www.trlsystems.com Service organization for this equipment: TRL SYSTEMS Address: 9531 MILLIKEN AVENUE Phone: 800-266-1392 Fax: E-mail: www.trlsystems.com Location of as-built drawings: TRL SYSTEMS Location of Historical Test Reports: TRL SYSTEMS OFFICE Location of system operation and maintenance manuals: FACILITY MAINT. DEPARTMENT A contract for test and inspection in accordance with NFPA standards is in effect as of N/A Contracted testing company: TRL SYSTEMS INC. Address: 9531 Milliken Avenue Phone: 909 390 8392 Fax: 909-390-8397 E-mail: Contract expires: n/a Contract number: Frequency of routine inspections: 3. Type of Fire Alarm System or Service NFPA 72®, Chapter Reference of System Type: CHAPTER 3 Name of organization receiving alarm signals with phone numbers (if applicable): Alarm: Rapid Response Monitoring Phone: 18002661392 Supervisory: Rapid Response Monitoring Phone: 18002661392 Trouble: Rapid Response Monitoring Phone: 18002661392 Entity to which alarms are retransmitted: Phone: Method of retransmission of alarms to that organization or location: DACT NFPA 72, Fig. 4.5.2.1 (p. 2 of 6) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. If Chapter 8, note the means of transmission from the protected premises to the central station: Digital alarm communicator McCulloh Multiplex 2-way radio 1-way radio N/A If Chapter 9, note the type of connection: Local energy Shunt N/A 3.1 System Software Operating system (executive) software revision level: Edward I/O 1000 Site-specific software revision date: 7-26-23 Revision completed by: TRL SYSTEMS 4. Signaling Line Circuits Characteristics of signaling line circuits connected to this system (see NFPA 72 ®, Table 6.6.1): Quantity: 3 Style: W Class: B 5. Alarm-Initiating Devices and Circuits Characteristics of initiating device circuits connected to this system (see NFPA 72®, Table 6.5): Quantity: 1 Style: 4 Class: B 5.1 Manual Initiating Devices 5.1.1 Manual Pull Stations Number of manual pull stations: 7 Type of devices: Addressable Conventional Coded Transmitter N/A 5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors Number of smoke detectors: 6 Type of coverage: Complete area Partial area Nonrequired partial area N/A Type of devices: Addressable Conventional Coded Transmitter N/A Type of smoke detector sensing technology: Ionization Photoelectric 5.2.2 Duct Smoke Detectors Number of duct smoke detectors: 6 Type of coverage: Partial Smoke coverage Type of devices: Addressable Conventional Coded Transmitter N/A Type of smoke detector sensing technology: Ionization Photoelectric 5.2.3 Heat Detectors Number of heat detectors: 2 Type of coverage: Complete area Partial area Nonrequired partial area N/A Type of devices: Addressable Conventional Coded Transmitter N/A 5.2.4 Sprinkler Waterflow Detectors Number of waterflow detectors: 1 Type of devices: Addressable Conventional Coded Transmitter N/A 5.2.5 Alarm Verification Number of devices subject to alarm verification: N/A Alarm verification on this system is: Enabled Disabled Set for seconds 6. Supervisory Signal-Initiating Devices and Circuits 6.1 Sprinkler System Number of valve supervisory switches: 2 Type of devices: Addressable Conventional Coded Transmitter N/A NFPA 72, Fig. 4.5.2.1 (p. 3 of 6) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 6.2 Fire Pump Type of fire pump: Electric Diesel Type of fire pump supervisory devices: Addressable Conventional Coded Transmitter N/A Fire Pump Functions Supervised Fire pump power Fire pump running Fire pump phase reversal Selector switch not in auto Engine or control panel trouble Low fuel Other: None 6.3 Engine-Driven Generator Type of generator supervisory devices: Addressable Conventional Coded Transmitter N/A Engine or control panel trouble Generator running Selector switch not in auto Low fuel Other: None 7. Annunciators 7.1 Annunciator 1 Local Remote Type: Addressable Directory Graphic N/A Location: Main Entrance 7.2 Annunciator 2 Local Remote Type: Addressable Directory Graphic N/A Location: 7.3 Annunciator 3 Local Remote Type: Addressable Directory Graphic N/A Location: 8. Alarm Notification Devices and Circuits 8.1 Emergency Voice Alarm Service Number of single voice alarm channels: N/A Number of multiple voice alarm channels: Number of speakers: Number of speaker zones: 8.2 Telephone Jacks Number of telephone jacks installed: N/A Number of telephone handsets stored on site: Type of telephone system installed: Electrically powered Sound powered N/A 8.3 Nonvoice Audible System Characteristics of notification device circuits connected to this system (see NFPA 72®, Table 6.5): Quantity: 3 Style: W Class: B NFPA 72, Fig. 4.5.2.1 (p. 4 of 6) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 8.4 Types and Quantities of Nonvoice Notification Appliances Installed Bells: With visual device: Horns: 20 With visual device: 20 Chimes: With visual device: Bells: With visual device: Visual devices without audible devices: 36 Other (describe): 9. Emergency Control Functions Activated Hold-open door releasing devices Smoke management or smoke control Door unlocking Elevator recall Other 10. System Power Supply 10.1 Primary Power Nominal voltage: 120V Amps: 20 AMP Overcurrent protection: Type: cir#7 breaker Amps: 20 AMP Location (of primary supply panelboard): FACP Disconnecting means location: 10.2 Secondary Power Location: Existing Type: Stand by Nominal voltage: 24v Current rating: 18.0 AH Number of standby batteries: 2 Amp hour rating: 18.0 AH Location of emergency generator: N/A Location of fuel storage: N/A Calculated capacity of secondary power to drive the system In standby mode: 24hrs. In alarm mode: 5 minutes NFPA 72, Fig. 4.5.2.1 (p. 5 of 6) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 11. Record of System Installation Fill out after all installation is complete and wiring has been checked for opens, shorts, ground faults, and improper branching, but before conducting operational acceptance tests. The system has been installed in accordance with the following NFPA standards: (Note any or all that apply.) NFPA 72® NFPA 70®, Article 760 Manufacturer’s published instructions Other (please specify): System deviations from referenced NFPA standards: N/A Signed: Printed name: Frank Arellano Date: 7-26-23 Organization: TRL Systems Title: Project Manager Phone: 800-266-1392 12. Record of System Operation All operational features and functions of this system were tested by or in the presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the r equirements of: NFPA 72® NFPA 70®, Article 760 Manufacturer’s published instructions Other (please specify): Documentation in accordance with Inspection and Testing Form (Figure 10.6.2.3 of NFPA 72®) is attached Signed: Printed name: Frank Arellano Date: 7-26-23 Organization: TRL Systems Title: Project Manager Phone: 800-266-1392 13. Certifications and Approvals 13.1 System Installation Contractor This system as specified herein has been installed and tested according to all NFPA standards cited herein. Signed: Printed name: Frank Arellano Date: 7-26-23 Organization: TRL Systems Title: Project Manager Phone: 800-266-1392 13.2 System Service Contractor This system as specified herein has been installed and tested according to all NFPA standards cited herein. Signed: Printed name: Frank Arellano Date: 7-26-23 Organization: TRL Systems Title: Project Manager Phone: 800-266-1392 13.3 Central Station This system as specified herein will be monitored according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.4 Property Representative I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.5 Authority Having Jurisdiction NFPA 72, Fig. 4.5.2.1 (p. 6 of 6) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and specifications, its approved sequence of operations, and with all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org May 15, 2023 TRL Systems Incorporated 9531 Milliken Ave Rancho Cucamonga, CA 91730 Re: Fire Alarm System Plan Review – WelBeHealth – I-4 OCCUPANCY FA2023-0001 / 46805 DUNE PALMS ROAD, LA QUINTA, CA 92253 The fire alarm system plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Duct Detector / Velocity Testing – Requires provision of magnometer/magnahelic gauge. c) Function Test / Start 24-hour Battery - The alarm installer shall provide all needed testing equipment to complete the final alarm inspection. d) 5-Minute Ring-out / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 46805 DUNE PALMS ROAD PERMIT#: FA2023-0001 DATE ISSUED: 5/15/2023 DESCRIPTION: WELBEHEALTH I-4 OCC CONTRACTOR: TRL SYSTEMS INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Insp ector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.