FHPR2020-0001ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AJ ORTEGA 10/13/2020 10/13/2020 EMAIL SENT TO APPLICANT THAT A SEPARATE BUILDING PERMIT WILL BE REQUIRED, NEEDS TO APPLY FOR A "STURCTURE OTHER THAN BUILDING" FOR THE CONSTRUCTION OF THE PROPOSED WORK. NOTE AARON HICKSON 10/6/2020 10/6/2020 STR ONLY TO HR GREEN PER JF. AND BUILDING REVIEW TELEPHONE CALL KOHL HETRICK 1/28/2021 1/28/2021 Spoke with Bedros, Requested update as to the planned resubmittal. Bedros is hoping to have the documents ready to submit early next week (first week of February 2021). I continue to do drive by inspection of the tire stacking to ensure they are maintaining it below 6-feet as was ordered, pending High-Pile Storage permit CONDITIONS Description: AMERICAN TIRE DEPOT / HIGH PILE STORAGE Type: FIRE HIGH PILE RACK STORAGE (WEB) Subtype: Status: FINALED Applied: 10/6/2020 EPRS Parcel No: 600010023 Site Address: 79762 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 2/17/2021 KHET Subdivision: PM 28593 Block: Lot: 2 Issued: 3/4/2021 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/13/2021 KHET Valuation: $7,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Thursday, February 16, 2023 11:57:14 AM 1 of 7 Permit Details City of La Quinta PERMIT NUMBER FHPR2020-0001 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT BEDROS DARKJIAN 2411 e. foothill bl pasadena CA 91107 (626)215-4826 darkjian@aol.com OWNER ARA TCHAGHLASSIAN 4490 AYERS AVE.VERNON OK 90053 (626)215-4826 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY HOURLY CHARGE - HR GREEN JUNIOR PROFESSIONAL 101-0000-42600 1 $130.00 $130.00 3/4/21 WEB7545 02186D CREDIT BEDROS DARKJIAN EPRS Total Paid for BLDG CITY STAFF - PER HOUR: $130.00 $130.00 FIRE HIGH PILE RACK STORAGE 101-0000-42421 0 $161.00 $161.00 10/5/20 R62669 WEB6416 CREDIT BEDROS DARKJIAN AMA FIRE HIGH PILE RACK STORAGE PC 101-0000-42420 0 $161.00 $161.00 10/5/20 R62669 WEB6416 CREDIT BEDROS DARKJIAN AMA Total Paid for FIRE FEES: $322.00 $322.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 10/5/20 R62669 WEB6416 CREDIT BEDROS DARKJIAN AMA Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 10/5/20 R62669 WEB6416 CREDIT BEDROS DARKJIAN AMA Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$467.00 $467.00 Printed: Thursday, February 16, 2023 11:57:14 AM 2 of 7 Permit Details City of La Quinta PERMIT NUMBER FHPR2020-0001 FIRE INSPECTOR KHET 4/22/2021 4/22/2021 DISAPPROVE D *Courtesy Checked-in on status of installed and adjusted racks. No inspections have been appropriately requested. Sought opportunity to educate and assist the management and ownership on how to finalize project. Emailed results: I have visited the site today to observe the current conditions. I’m trying to help in getting this project completed and finaled. To note, the 4th row of racks (3rd double- row) has been eliminated due to the impacts to the operational work space needs. The cross arm assembly spanning the overhead of the aisleways and connecting the rack verticals has been modified by a welding of an approximately 8-inch extension. Here is a link to view the photos I took. https://photos.app.goo.gl/NxpzZrCKze8Ta1 zW8 Attached are my field notes documented on the fire plan set. I have included slight measurement modifications observed. I will defer to building as far as any revision needs or certifications. Regardless, coordinated and scheduled inspections both with Building and Fire are needed. Respectfully, Printed: Thursday, February 16, 2023 11:57:14 AM 3 of 7 Permit Details City of La Quinta PERMIT NUMBER FHPR2020-0001 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/6/2020 EtrakitPublicReg 1ST SUBMITTAL SITE PLAN 001652_Americn Tire Depot_Site Plan (1).pdf 1 BOND INFORMATION HIGH PILE RACK STORAGE KHET 5/12/2021 5/12/2021 APPROVED APPROVED AS-BUILTS ATTACHED FIRE FINAL**KHET 5/12/2021 5/13/2021 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST BLDG STR (2 WK) HR GREEN 10/6/2020 10/20/2020 10/12/2020 REVISIONS REQUIRED 1ST BLDG NS (2 WK)AJ ORTEGA 10/6/2020 10/20/2020 10/13/2020 NOT REQUIRED THIS IS A FIRE APPLICATION THAT BUILDING DOES NOT REVIEW FOR APPROVAL, APPLICANT TO SEPARATELY SUBMIT FOR A PERMIT TYPE OF "STRUCTURE OTHER THAN BUILDING" FOR REVIEW AND APPROVAL OF PROPOSED SCOPE OF WORK. 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 10/6/2020 10/7/2020 10/6/2020 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 10/6/2020 10/20/2020 10/19/2020 REVISIONS REQUIRED SEE ATTACHMENTS 2ND FIRE (1 WK)KOHL HETRICK 11/30/2020 12/7/2020 12/7/2020 REVISIONS REQUIRED SEE ATTACHMENTS BLDG TO REVIEW UNDER NEW BOTH2020-0009 RACK PERMIT. 3RD FIRE (1 WK)KOHL HETRICK 2/8/2021 2/17/2021 2/17/2021 APPROVED SEE ATTACHMENTS Date Due posted out 2 days due to County Holidays PARENT PROJECTS Printed: Thursday, February 16, 2023 11:57:14 AM 4 of 7 Permit Details City of La Quinta PERMIT NUMBER FHPR2020-0001 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/6/2020 EtrakitPublicReg 1ST SUBMITTAL FLOOR PLAN 001652_Americn Tire Depot_Floor Plan (1).pdf 1 DOC 10/6/2020 EtrakitPublicReg 1ST SUBMITTAL COVER SHEET LA QUINTA COVER SHEET SITE PLAN.pdf 1 DOC 10/6/2020 EtrakitPublicReg 1ST SUBMITTAL BUILDING APPLICATION APPLICATION.pdf 1 DOC 10/6/2020 EtrakitPublicReg 1ST SUBMITTAL STRUCTURAL CALCS structural calcs..pdf 1 DOC 10/6/2020 EtrakitPublicReg 1ST SUBMITTAL STRUCTRAL PLAN SHEET STRUCTURAL_1.pdf 1 DOC 11/30/2020 EtrakitPublicReg 2ND SUBMITTAL - HIGH- PILE RACK PLAN 001652_Americn Tire Depot_Merged_FPE Stamped 11-18-20.pdf 1 DOC 11/30/2020 EtrakitPublicReg 2ND SUBMITTAL - APPLICANT RESPONSE TO CORRECTIONS American Tire Depot (La Quinta)_Response Letter (1).pdf 1 DOC 11/30/2020 EtrakitPublicReg 2nd Submittal - FPE TECHNICAL REPORT Technical Report_American Tire Depot_FPE Stamped (1).pdf 1 DOC 3/4/2021 EtrakitPublicReg site plan A-1.pdf 1 DOC 3/4/2021 EtrakitPublicReg floor plan A-2.pdf 1 DOC 3/4/2021 EtrakitPublicReg structural plan S1 (3).pdf 1 DOC 3/4/2021 EtrakitPublicReg calculations 20345-79840 State Highway 111, La Quinta.pdf 1 DOC 10/12/2020 HR GREEN 1ST REVIEW STRUCTURAL PLAN MARKUP STRUCTURAL_1- corrections.pdf 0 Printed: Thursday, February 16, 2023 11:57:14 AM 5 of 7 Permit Details City of La Quinta PERMIT NUMBER FHPR2020-0001 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/12/2020 HR GREEN 1ST REVIEW STRUCTURAL CORRECTION LIST FHPR2020-0001 correction list.pdf 0 DOC 10/12/2020 HR GREEN 1ST REVIEW STRUCTURAL TRANSMITTAL FHPR2020-0001 79840 Highway 111 correction transmittal.pdf 0 DOC 10/19/2020 KOHL HETRICK FHPR2020-0001 - 1ST REVIEW - CORRECTIONS.pdf FHPR2020-0001 - 1ST REVIEW - CORRECTIONS.pdf 1 DOC 12/7/2020 KOHL HETRICK FHPR2020-0001 - FPE TECH RPT - APPROVED.pdf FHPR2020-0001 - FPE TECH RPT - APPROVED.pdf 1 DOC 12/7/2020 KOHL HETRICK FHPR2020-0001 - 2ND REVIEW - CORRECTIONS.pdf FHPR2020-0001 - 2ND REVIEW - CORRECTIONS.pdf 1 DOC 12/7/2020 KOHL HETRICK FHPR2020-0001 - 2ND PC - CORRECTIONS.pdf FHPR2020-0001 - 2ND PC - CORRECTIONS.pdf 1 DOC 2/17/2021 KOHL HETRICK FHPR2020-0001 - APPROVED PLANS.pdf FHPR2020-0001 - APPROVED PLANS.pdf 1 DOC 2/17/2021 KOHL HETRICK FHPR2020-0001 - COA AND JOB CARD.pdf FHPR2020-0001 - COA AND JOB CARD.pdf 1 DOC 4/22/2021 KOHL HETRICK FHPR2020-0001 - 4-22- 2021 - INSP NOTES.pdf FHPR2020-0001 - 4-22- 2021 - INSP NOTES.pdf 1 DOC 5/13/2021 KOHL HETRICK FHPR2020-0001 - 5-12- 2021 - APPROVED AS- BUILTS.pdf FHPR2020-0001 - 5-12- 2021 - APPROVED AS- BUILTS.pdf 1 PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0463.JPG IMG_0463.JPG 0 PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0464.JPG IMG_0464.JPG 0 Printed: Thursday, February 16, 2023 11:57:14 AM 6 of 7 Permit Details City of La Quinta PERMIT NUMBER FHPR2020-0001 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0465.JPG IMG_0465.JPG 0 PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0466.JPG IMG_0466.JPG 0 PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0467.JPG IMG_0467.JPG 0 PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0469.JPG IMG_0469.JPG 0 PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0474.JPG IMG_0474.JPG 0 PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0475.JPG IMG_0475.JPG 0 PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0477.JPG IMG_0477.JPG 0 PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0478.JPG IMG_0478.JPG 0 PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0479.JPG IMG_0479.JPG 0 PHOTO 10/7/2020 KOHL HETRICK Code Case IMG_0480.JPG IMG_0480.JPG 0 Printed: Thursday, February 16, 2023 11:57:14 AM 7 of 7 Permit Details City of La Quinta PERMIT NUMBER FHPR2020-0001 HIGH PILE STORAGE - SITE PLANAMERICAN TIRE DEPOT79840 HIGHWAY 111LA QUINTA, CA 92253C. KAANOIJ.MARTINEZ10/01/2010/01/20PWP016521" = 20'-0"D12PREMIER WAREHOUSE PERMITS, INC565 PORTER WAYPLACENTIA, CA 92870PH: 714.269.8693INFO@WAREHOUSEPERMITS.COMH I G H W A Y 1 1 1SCOPE OFWORKVICINITY MAPCODE INFORMATIONAPPLICABLE CODES:3.)2019 CALIFORNIA GREEN BUILDING CODE (C.G.C.)4.)2019 CALIFORNIA REFERENCE STANDARDS CODE5.)2019 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE6.)CCR TITLE 19 - PUBLIC SAFETY: DIVISION 1 - STATE FIRE MARSHAL7.)2016 NFPA 13 - STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS8.)APPLICABLE ORDINANCES OF THE STATE FIRE MARSHAL1.)2.)THE 2019 EDITION OF THE CALIFORNIA BUILDING CODE (CBC) ADOPTS THE 2018INTERNATIONAL BUILDING CODE (IBC) AND THE 2019 CALIFORNIA AMENDMENTS.THE 2019 EDITION OF THE CALIFORNIA FIRE CODE (CFC) ADOPTS THE 2018INTERNATIONAL FIRE CODE (IFC) AND THE 2019 CALIFORNIA AMENDMENTS.1 OF 22 OF 2SITE PLANFLOOR PLANNO.SHEET TITLEENGINEERING:1 OF 1STORAGE RACK DETAILSPROPERTY OWNER:PROJECT DIRECTORY14407 ALONDRA BLVD.LA MIRADA, CA 90638SHEET INDEXTENANT79840 HIGHWAY 111LA QUINTA, CA 92253ROLL UPDOORSFIRE DEPARTMENT ACCESS ROADFIRE DEPARTMENT ACCESS ROADFIRE DEPARTMENT ACCESS ROADFIRE DEPARTMENT ACCESS ROADEXISTINGFDC LOCATIONFIREHYDRANTTYPE OF CONSTRUCTION PER C.B.C.:OCCUPANCY GROUP PER C.B.C.:BUILDING (OFFICE / MANUFACTURING / WAREHOUSE) B AND S-1EXISTING BUILDING HEIGHT :PROJECT INFORMATIONEXISTING USE :PROPOSED USE :BUILDINGS ON SITE :REQUIRED PERMITS :BUILDING ADDRESS :WAREHOUSE79840 HIGHWAY 111LA QUINTA, CA 92253 BUILDING AND SAFTEY ANDFIRE PERVENTIONDETAILED SCOPE OF WORK:22'-0"ASSESSOR'S PARCEL NUMBER :WAREHOUSEINSTALL HIGH PILE STORAGE RACKS IN WAREHOUSE AREA.TYPE III-B6000100231NUMBER OF STORIES:AREA:SPRINKLERED.:YESFHPR2020-0001AS-BUILTS TRANSVERSE: MINIMUM 3 INCHES, VERTICALLY ALIGNED NOT REQUIRED LONGITUDINAL: NOT REQUIRED CFC TABLE 3208.3 SINGLE ROW RACKS -DEPTH OF RACKS: -MAXIMUM STORAGE HEIGHT: NUMBER OF TIERS: STORAGE METHOD: 5 BEAM LEVELS RACK STORAGE 15'-0" FT. RACK STORAGE 1'-2" FEET 3" TRANSVERSE / 6" LONGITUDINAL-FLUE SPACE: 4' FT - 0" INCHES MINIMUM -AISLE WIDTHS BETWEEN RACKS: -WIDTH OF INDIVIDUAL BAYS:60" WIDE BAYS BEAM LOADED OR WIRE MESH DECKS-SHELF TYPE: 5,746 SQ. FT. OF WAREHOUSE AREA-WAREHOUSE AREA: 2,480 SQ. FT. OF HIGH-PILE STORAGE-WAREHOUSE HIGH-PILE AREA: OCCUPANCY TYPE: B (OFFICE), S-1 (STORAGE), M (MANUFACTURING CONSTRUCTION TYPE: TYPE V-B FIRE SPRINKLERS: FULLY SPRINKLED BUILDING HEIGHT: 22'-0" PER TABLE 3206.2 OF CFC (501 - 2,500 SQ. FT) HIGH HAZARD NON-PUBLIC DRAFT CURTAINS ARE NOT REQUIRED BUILDING ACCESS IS NOT REQUIRED (SEE PLAN FOR ACCESS ROAD AND DOORS) PER TABLE 3206.2 OF CFC (501 - 2,500 SQ. FT) HIGH HAZARD NON-PUBLIC A FIRE DETECTION SYSTEM IS NOT REQUIRED PER TABLE 3206.2 OF CFC (501 - 2,500 SQ. FT) HIGH HAZARD NON-PUBLIC PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN ACCORDANCE WITH 2019 CFC SECTION 906 AND RIVERSIDE COUNTY FIRE DEPARTMENT STANDARDS DEPARTMENT STANDARDS, LOCATIONS SHALL BE PROVIDED BY PROPERTY OWNER KNOX BOXES SHALL BE PROVIDED IN ACCORDANCE WITH RIVERSIDE COUNTY FIRE KNOX BOX LOCATION LOCATED IN FRONT ENTRANCE OF OFFICE IF ANY HOSE RACKS EXIST, THEY CAN BE REMOVED AND CAPPED OFF AT THE PROPERTY EQUIPPED WITH FIRE DEPARTMENT CONNECTIONS THERE WILL BE NO IDLE PALLET STORAGE IN THIS WAREHOUSE AT THIS TIME SPRINKLER SYSTEM AT THIS TIME, IF ANY ALTERNATIONS ARE TO BE PERFORMED THERE WILL NOT BE ANY FIRE SPRINKLER ALTERATIONS TO THE EXISTING A SEPARATE PERMIT WILL NEEDED TO PERFORM SUCH WORK RIVERSIDE COUNTY FIRE DEPARTMENT STANDARDS ALL PRIVATE FIRE HYDRANT CAPS MUST BE PAINTED IN ACCORDANCE WITH HAZARDOUS MATERIALS TO BE PRESENT. IF THERE ARE TO BE ANY HAZARDOUS THIS REVIEW DID NOT INCLUDE ANALYSIS OF ANY FLAMMABLE LIQUIDS OR MATERIALS PRESENT IN EXCESS OF EXEMPT AMOUNTS, THE APPLICANT MUST PROVIDE IT TO THE FIRE DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO INTRODUCTION OF A LETTER IDENTIFYING THE MATERIALS TO BE STORED AND/OR USED AND RETURN SUCH MATERIALS INTO THE BUILDING. GROUP A PLASTIC COMMODITIES: PER CFC TABLE 3203.8 - RUBBER, NATURAL (NONEXPANDED) COMMODITY: RUBBER TIRES, ON TREAD (UPRIGHT) STORED EXPOSED DIRECTLY ON FIXED RACKS. PLACED ON RACKS TO A HEIGHT OF 15'-0" TOP OF STORAGE. ACCESSIBLE HYDRANT(S) SHALL BE PROVIDED AND LOCATED WITHIN 150 FEET OF ALL PORTIONS OF EXTERIOR WALL ON THE FIRST FLOOR AS MEASURED IN AN APPROVED ROUTE AROUND THE BUILDING IN CONFORMANCE WITH CITY STANDARDS. FIRE DEPARTMENT FINAL INSPECTION REQUIRED. SCHEDULE ALL INSPECTIONS A MINIMUM 48 HOURS IN ADVANCE BY CALLING (760) 777-7131 SHALL BE APPROVED PRIOR TO INSTALLATION AND SHALL BE IN COMPLIANCE FIRE APPARATUS ACCESS ROADS SHALL BE UNOBSTRUCTED. ACCESS GATES WITH 2019 CFC 504 AND RIVERSIDE COUNTY FIRE DEPARTMENT STANDARDS 2019 CFC CHAPTER 9. A SEPARATE PLAN SUBMITTAL IS REQUIRED FOR THE MONITORED BY A U.L. LISTED CENTRAL ALARM STATION OR BE SUPERVISED PER AUTOMATIC FIRE SPRINKLER SYSTEMS AND ALL CONTROL VALVES SHALL BE INSTALLATION OF THE MONITORING SYSTEM. THUMB-TURN LOCKS OR DEADBOLTS THAT DO NOT UNLATCH IN TANDEM WITH THE OR ANY SPECIAL KNOWLEDGE OR EFFORT. DOORS SHALL NOT BE PROVIDED WITH EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITH OUT THE USE OF A KEY NORMAL OPERATING LEVEL. THE OPENING FORCE FOR INTERIOR DOORS WITHOUT CLOSER SHALL NOT EXCEED 5 POUNDS THE UNLATCHING AND OPENING FORCE FOR OTHER DOORS SHALL NOT EXCEED 15 POUNDS 2019 C.B.C. 1010. ONE MOTION HARDWARE ACCESSIBLE FROM INSIDE AND OUTSIDE. ALL ACCESS ALL EXTERIOR ACCESS DOORS SHALL BE 6'-8" X 3'-0" MAN DOORS WITH DOORS TO HAVE EXTERIOR LEVER HARDWARE AND ABLE TO OPEN FROM OUTSIDE. A 5 YEAR SPRINKLER CERTIFICATION IS REQUIRED TO BE CURRENT ISSUED BY AN RIVERSIDE COUNTY FIRE DEPARTMENT FIRE INSPECTOR. A CFC PERMIT IS REQUIRED FOR HIGH PILE STORAGE. THIS PERMIT WILL BE CEILING. A SEPARATE PERMIT IS REQUIRED FOR SUCH WORK. 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA FIRE CODE NFPA 13 2016 EDITION RIVERSIDE COUNTY FIRE DEPARTMENT STANDARDS THIS PLAN IS INTENDED FOR CONSTRUCTION IT IS A HIGH PILED STORAGE DESIGN AND REPORT IN CONJUCTION WITH BUILDING STRUCTURAL PLANS. IT'S PURPOSE IT TO ESTABLISH THE STORAGE REQUIREMENTS FOR THE TENANT AND BUILDING WHICH AND 2019 CALIFORNIA BUILDING CODE REQUIREMENTS. ANY AND ALL MODIFICATIONS COMPLIES WITH THE APPLICABLE 2019 CALIFORNIA FIRE CODE, NFPA 13 2016 EDITION, TO THE BUILDING ARE THE SOLE RESPONSIBILITY OF THE OWNER/TENANT. THE OWNER/TENANT SHALL OBTAIN A LICENSED CONTRACTOR TO PERFORM SUCH WORK. ALONG WITH THE NECESSARY PERMIT FOR SUCH WORK. THE EXISTING SPRINKLER SYSTEM IS A 35 PSI EARLY SUPPRESSION FAST RESPONSE SYSTEM (ESFR) WITH ESFR K-16.8 HEADS NFPA 13 (2016) EDITION TABLE 18.4(D) ESFR (PROTECTION OF RUBBER TIRES) THIS SPRINKLER SYSTEM ALLOWS FOR RACK TIRE STORAGE UP TO 25'-0" -RUBBER TIRE STORAGE, STORED ON TREAD IN RACKS, NON-ENCAPSULATED OR WITHIN 36" OF SPRINKLER HEADS, WHICHEVER IS LESS FOR THE REQUIRES AN ESFR SYSTEM WITH A MINIMUM OPERATING PRESSURE OF 35 PSI RACK STORAGE: UTILIZING K-16.8 HEADS WITH A MAXIMUM STORAGE HEIGHT OF 25'-0" TOP SPRINKLER HEAD TEMPERATURE RATING: 212°F STORAGE AND A MAXIMUM CEILING HEIGHT OF 30'-0" FOLLOWING COMMODITIES: -NO OPEN TOP CONTAINERS PER NFPA 13 (2016) 18.2.4 NOT REQUIRED: WHEN (ESFR) EARLY SUPPRESSION FAST RESPONSE SPRINKLER SYSTEMS IS PROTECTING THE HIGH PILE STORAGE AREAS AND STEEL COLUMNS -NO SOLID SHELVES TRANSVERSE: MINIMUM 3 INCHES, VERTICALLY ALIGNED NOT REQUIRED LONGITUDINAL: MINIMUM 6 INCHES CFC TABLE 3208.3 DOUBLE ROW RACKS OPTION #2 BUILDINGS PER 3206.9.1.1 MINIMUM 44" WIDE AISLES REQUIRED FOR HIGH PILED STORAGE IN SPRINKLER REQUIRED, THE EXIT ACCESS SHALL BE ARRANGED SUCH THAT THERE ARE NO PER SECTION 1020.4 WHERE MORE THAN ONE EXIT OR EXIT ACCESS DOORWAY IS DEAD END IN CORRIDORS MORE THAN 20 FEET IN LENGTH. EXCEPTION #2: IN OCCUPANCIES IN GROUPS "S" WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 THE LENGTH OF THE DEAD-END CORRIDORS SHALL NOT EXCEED 50 FEET. OCCUPANCY FOR THIS BUILDING IS S (WAREHOUSE) ALL SMOKE AND HEAT VENTS ARE NOT REQUIRED FOR HIGH PILE STORAGE PER TABLE 3206.2 OF CFC (501 - 2,500 SQ. FT) HIGH HAZARD NON-PUBLIC WHERE STORAGE AREAS WITH AN EXIT ACCESS TRAVEL DISTANCE OF 250 FEET OR LESS ARE PROTECTED BY AN ESFR SYSTEM. SMOKE VENTS ARE NOT REQUIRED WHEN STORAGE AREAS WITH AN EXIT TRAVEL DISTANCE OF 250 FEET OR LESS AREA PROTECTED BY AN EARLY SUPPRESSION FAST RESPONSE (ESFR) SPRINKLER SYSTEMS INSTALLED IN ACCORDANCE WITH SEC. 903.3.1.1 FIRE EXTINGUISHERS SHALL BE A MINIMUM 4A:60B:C MAXIMUM TRAVEL DISTANCE SHALL NOT EXCEED 75 FEET FOR EXTRA HAZARD 60" 7" 35" 35" 35" 35" 156" TOP OF UPRIGHT 12"12" 32'-8"43'-11"28'-2"26'-3"21'-3"30'-7"2'3'-8"HIGH PILE STORAGE - FLOOR PLANAMERICAN TIRE DEPOT79840 HIGHWAY 111LA QUINTA, CA 92253C. KAANOIJ.MARTINEZ10/01/2010/01/20PWP01652 3 32" = 1'-0" D 2 2PREMIER WAREHOUSE PERMITS, INC565 PORTER WAYPLACENTIA, CA 92870PH: 714.269.8693INFO@WAREHOUSEPERMITS.COMROLL UPDOORSELECTIVE RACK TYPE A 6"15'-0" TOP OF STORAGE22'-0" CEILING HEIGHT66" MINIMUM CLEARANCE TO CEILING SPRINKLERS 4'-8" 4'-8" 4'-8" A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A4'-3"12"1" 6"4'-8" 3'-8" 2' 2'-2" 1'-6" AMERICAN TIRE DEPOT79-840 HIGHWAY 111,LA QUINTA,CA.92253SHEET CONTENTARCHITECTURAL STRUCTURAL PLANSPROJECT CONSULTANTS1ƒ : 1ƒ ( PARCEL 3PM 285731ƒ : 1ƒ ( BASIS OF BEARINGSHIGHWAY 11118'X14' ROLL UP DOOR SUMP PUMPVICINITY MAPSYMBOLS & ABBREVIATIONS PROJECT INFORMATION APPLICABLE CODESSITE PLANSCOPE OF WORK#/'4+%#06+4'&'216 Ä*+)*9#; .#37+06#%# (14/4#4#6%*#)*.#55+#0 PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCTPRODUCED BY AN AUTODESK EDUCATIONAL PRODUCTPRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT S-1 COLD-FORMED METAL FRAMING STRUCTURAL STEEL GENERAL NOTES: REINFORCING STEEL: SOIL INFO.: CONCRETE: PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCTPRODUCED BY AN AUTODESK EDUCATIONAL PRODUCTPRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT ________________________________________________________________________ High Piled Combustible Storage Technical Report American Tire Depot 79840 Highway 111 La Quinta, CA 92253 565 Porter Way Placentia, Ca 92870 Ph: (714) 269-8693 Fx: (877) 269-8657 High Pile Storage Technical Report, American Tire Depot 1 Table of Contents 1.0 Introduction: Page 2 2.0 Code References Page 2 3.0 Warehouse Description Page 2 4.0 Code Analysis Page 2 4.1 High Pile Storage Commodities and Arrangement Page 3 4.2 Designation of High Pile Storage Areas Page 3 4.3 General Fire Protection and Life Safety Requirements Page 4 4.3.1 Automatic Fire Extinguishing System Page 4 4.3.2 Building Access Page 5 4.3.3 Smoke and Heat Vent Removal Page 5 4.3.4 Flue Space Requirements Page 6 4.3.5 General Requirements Page 6 4.3.6 Curtain Board Information Page 7 4.3.7 Fire Detection System Page 7 5.0 General Warehouse Information Page 7 6.0 Conclusion Page 7 Site Plan Page 8 Floorplan Page 9 High Pile Storage Technical Report, American Tire Depot 2 1.0 Intro: American Tire Depot contracted Premier Warehouse Permits, Inc. to provide a thorough High Pile Storage analysis for their facility located at 79840 Highway 111, La Quinta CA 92253. This analysis will identify all applicable code requirements for their warehouse and determine whether their existing fire sprinkler protection system shall be adequate for High Pile Storage and provide analysis for other warehouse features to determine if those features meet or exceed current code requirements. 2.0 Code References: The following code references were used in determining this High Pile Storage Report: 1. California Fire Code, 2019 Edition (CFC) 2. NFPA 13, Installation of Fire Sprinkler Systems, 2016 Edition 3. California Building Code, 2019 Edition (CBC) 4. City of La Quinta Municipal Code 3.0 Warehouse Description: The warehouse located at 79840 Highway 111, La Quinta CA 92253 is a single-story structure with a Construction Type of III-B per (CBC) with automatic sprinklers. ` The total floor area is approximately 5,746 square feet with a Ceiling Height of 22’-0” at the peak of the warehouse. American Tire Depot intends to occupy the entire warehouse (5,746 square feet) in which 2,392 square feet is proposed to be used for High Pile Storage. 4.0 Code Analysis: High Pile Storage defined as per CFC 2019 Edition (3202.1 Definitions) states “Storage of combustible materials in closely packed piles or combustible materials on pallets, in racks, or on shelves where the top of storage is greater than 12’-0” in height. When required by the fire code official, high-piled combustible storage also includes certain high-hazard commodities, such as rubber tires, Group A plastics, flammable liquids, idle pallets and similar commodities where the top of storage is greater than 6’-0” in Height. The requirements applicable to American Tire Depot at 79840 Highway 111, La Quinta CA 92253 will be addressed in a thorough High-Pile Storage Analysis listed in this report. This analysis will identify the necessary requirements and recommend any additional requirements that need to be addressed. This analysis will also provide a complete classification of commodities to be stored as defined by applicable fire codes. High Pile Storage Technical Report, American Tire Depot 3 4.1 High Pile Storage Commodities & Arrangement: American Tire Depot is proposing to store the following: High Hazard/Group A Plastic Tires. Tires will be stored uprights on Tread and exposed. The listed commodities in the rack storage configuration will have a maximum storage height of 15’-0” (to the top of the commodity). The High Pile Storage Design will maintain aisle widths of 4’-0” or greater at all times. The types of commodities and code reference that classifies these commodities will follow. Plastic pallets will not be stored or utilized throughout the warehouse. Group A Plastics/High Hazard Commodities: Per CFC (2019) 3203.8 Tires to be stored uprights on Tread and exposed: - Rubber Tires. Commodity: Rubber Tires. Tires to be stored upright on Tread and exposed, placed on racks to a height of 15’-0” top of storage. 4.2 Designation of High-Piled Storage Areas: California Fire Code (2019 Edition) establishes requirements for Sprinkler Systems, Smoke & Heat Vents, Fire Detection Systems, Building Access, aisle widths, and pile sizes. The Fire Code Defines a High Pile Storage Area as stated, “An area within a building which is designated, intended proposed or actually used for High-Piled combustible storage.” The proposed area of the High-Piled Storage area located at 79840 Highway 111, La Quinta CA 92253 will be approximately 2,392 square feet. High Pile Storage areas and portions of High-Piled storage areas intended for storage of different commodity class than adjacent areas shall be designed and specifically designated to contain Class I, Class II, Class III, Class IV or High Hazard Commodities. The designation of a High-Piled combustible storage area, or portion thereof, intended for storage of a different commodity class shall be based on the highest hazard commodity class stored except as provided in section 3204.2 of the CFC (2019 Edition). As proposed in Section 4.1, the highest hazards of commodities stored at 79840 Highway 111, La Quinta CA 92253 will be Rubber Tires/Unexpanded Group A Plastics. Section 3206.3 of the California Fire Code (2019 Edition) requires separation of High- Piled Storage areas from other portions of the building where required by Sections 3206.3.1 through 3206.3.2.2. Section 3206.3.1 requires separation of mixed occupancies shall be in accordance with California Building Code (2019 Edition). Based on 2019 CBC Table 508.4 there is no requirements for occupancy separation between B (Office) and S-1 (Warehouse) occupancies. High Pile Storage Technical Report, American Tire Depot 4 4.3 General Fire Protection and Life Safety Requirements: Based on the proposed commodities in Section 4.1 of this report and the High-Pile storage area in section 4.2 of this report, the following features will be required based on Table 3206.2 of the CFC 2019 (High Hazard Commodities 501 – 2,500 sq. ft.): 1. Automatic Fire Extinguishing System (Section 4.3.1) (Required) 2. Building Access (Section 4.3.2) (Not Required) 3. Smoke and Heat Vent Removal (Sections 3206. and 910) (Not Required) 4. General Storage Requirements (Section 4.3.4) 5. Fire Detection System (Section 4.3.6) (Not Required) 4.3.1 Automatic Fire Extinguishing System: (Required) Table 3206.2 of CFC (2019 Edition) requires that adequate Fire Extinguishing Systems be installed for High Pile Storage. This building is protected with an Automatic wet pipe Sprinkler System. The current system installed at 79840 Highway 111, La Quinta CA 92253 is an Early Suppression Fast Response (ESFR) Sprinkler System. This system is installed throughout the warehouse. The ESFR Systems are designed with K-16.8 Sprinkler Heads operating at a minimum of 35 PSI. The aforementioned information was acquired by reading the existing sprinkler placard located on the existing fire sprinkler riser. Per NFPA 13 (2016 Edition) the sprinkler design criteria for High Pile Storage for Tire Storage can be found in Table 18.4(D) ESFR Protection of Rubber Tires. This table shows the allowable storage height, maximum ceiling height, minimum operating pressure, and required sprinkler head. Below you will find the needed protection for this High Pile Storage application Rack Storage Design: NFPA 13 (2016) Edition Table 18.4(D) ESFR Protection of Rubber Tire Commodities Requires: ESFR Sprinkler System with a minimum operating pressure of 35 PSI and Nominal K- Factor of 16.8 Sprinkler heads with a temperature rating of 212°F and a maximum ceiling height of 30’-0”. This allows for Storage up to 25’-0” Feet or within 36” of Sprinkler Heads (whichever is less) of the following Commodities: - Rubber Tires - Stored Upright on Tread Exposed American Tire Depot intends to store Rubber Tires to a height of 15 feet on racks. See section 4.1 of this report for a precise description of the commodities. 984 High Pile Storage Technical Report, American Tire Depot 5 4.3.2 Building Access: (Not Required) Per Table 3206.2 of the CFC (2019) states that building access is not required. Section 3206.6 states that fire apparatus access roads in accordance with Section 503 shall be provided within 150 feet of all portions of the exterior wall of buildings used for High- Pile Storage. Fire apparatus access roads shall have unobstructed width of not less than 20 feet except for approved security gates in accordance with section 503.6, and an unobstructed vertical clearance of not less than 13 feet 6 inches. A turning radius shall be provided. Dead-end fire apparatus access roads in excess of 150 feet in length shall be provided with an approved area for turning around fire apparatus. Section 3206.6.1.1 requires one (1) access door shall be provided in each 100 lineal feet, or fraction thereof, of the exterior walls which face required fire apparatus roads. The building in question is in compliance with all building access requirements. Please see High-Pile Storage drawings for fire apparatus access roads and access doors. It should be noted that this building, although existing, also complies with the Riverside County Fire Department Codes and Standards for the width of Fire Department Access Lanes. 4.3.3 Smoke Vents and Heat Removal (Not Required) Per table 3206.2 of CFC 2019 (501 – 2,500 Sq. Ft.) High Hazard Commodities All smoke and heat vents are not required for High Pile Storage when High Pile Storage areas do not exceed 2,500 Sq. Ft. High Pile Storage Area for this project is 2, 0 Square Feet Storage area was calculated using 15’-0” beyond the Storage Racks. 4.3.4 Flue Space Requirements: CFC Table 3208.3 Single Row Rack (Option #1) Longitudinal: Not Required Transverse: Minimum 3 Inches, Vertically Aligned Not Required CFC Table 3208.3 Double Row Rack (Option #1) Longitudinal: 6 Transverse: Minimum 3 Inches, Vertically Aligned Not Required 4.3.5 General Requirements: The limitations stated above comply with the proposed storage arrangement for this building. Aisles in sprinklered buildings shall be a minimum of 48 inches wide. Dead-end aisles shall be a maximum length of 50’-0” in accordance with Chapter 10.. Portable Fire extinguisher shall be provided in accordance with 2016 California Fire Section 906 (Type 4A). Maximum travel distance 75 Feet 840 8 APPROVED By: FIRE SAFETY SPECIALIST 12/07/2020 1:42:41 PM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. PERMIT # -FHPR2020-0001 Page 1 of 2 City of La Quinta BUILDING AND SAFETY PLAN CHECK COMMENTS PLAN CHECK NO.: FHPR2020-0001 STATUS: CORRECTIONS PROJECT ADDRESS: 79840 Highway 111 DATE SUBMITTED: 10/06/2020 WORK DESCRIPTION: High Pile Storage Racks APPLICANT NAME: TEL NO: ADDRESS: EMAIL: USE OCCUPANCY GROUP FLOOR AREA SF OCCUPANT LOAD TYPE OF CONSTR. NO. OF STORIES FIRE SPRINKLER (Y/N) VALUATION U The approval of plans and specifications does not permit the violation of any sections of the California Building Codes, local ordinances, or state laws. In an effort to speed up the plan review process, follow the steps provided below to ensure that there is no delay in processing your application and reviewing your responses to these plan check comments. • Revised plans and calculations shall incorporate and address all comments marked on the original checked set of plans, calculations, and this plan check comment list. • Provide a written response to each comment adjacent to the comment listed • Cloud the location on the plan where it has been addressed and how. • Identify, in your response letter, the sheet number, detail, or reference note on the revised plans where the corrections were made. • Time spent searching for the corrected items on the revised plans or c alculations may delay the review and approval process. PLAN CHECKER: Beth Jay TEL. NO.: 213-375-8744 ADDRESS: 78-495 Calle Tampico, La Quinta, CA 92253 DATE: 10/09/2020 Should you have any questions or need clarification pertaining to the comments made on your project, you may contact the plan check staff by telephone from 8:00 A.M. to 4:00 P.M. • Bring the original checked set of plans and calculations along with this comment list to the City of La Quinta . • Do not submit plans for review with the plan check staff until all comments have been addressed. • Return this Comment list with separate itemized list showing how the item was resolved and where to find it on the plans and the Red Marked set of plans along with (3) three complete revised sets of plans, calculations (if applicable). Defaced, incomplete, indefinite, or faded drawings or calculations will not be accepted. Failing to provide the information may result in your review being delayed or returned for additional information. Page 2 of 2 A. STRUCTURAL COMMENTS 1. Have engineer of record sign and date all sheets. 2. Update all codes referenced to current codes including 2019 CBC. END OF PLAN REVIEW ________________________________________________________________________ Attn: Kohl Hetrick Riverside County Fire Department Re: FHPR2020-0001 (Corrections) Correction #1: Understood Correction #2: Understood Correction #3A: Plans have been stamped by an FPE and Tech Report included Correction #3B: Revised floor plan to show current racking configuration Correction #3C: All dimensions have been confirmed Correction #3D: All dimensions have been confirmed Correction #3E: Understood, see Tech Report 565 Porter Way Placentia, CA 92870 Ph: (714) 269-8693 Fx: (877) 269-8657 PIAN CHECK COMMENTS TRANSMITTAL SHEET HRGreen Project Address: 79840 Highway 111 Occupancl Group: U Storiesi 1 Plan Check Coordinator: Beth Jay til 1st Review E] 2nd Review E 3rd Review til 4th or More Hourly Plan Check Hours: 1.0 hour The project plans were reviewed for compliance with the following codes and standards: 2019 CBC; 2019 CRC, 2019 CPC; 2019 CEC; 2019 CMC; 2019 Building Energy Efficiency Standards; 2019 CAL Green Building Standards Code The code section references are from the 2019 CBC, unless otherwise stated. FOR PROJECT APPROVAT: .1. Please provide a written response indicating how and where each comment was resolved on the plans. .:. Resubmit all previously reviewed plans, updated plans, and supporting documents with each subsequent review- t For clarification ofany plan review comment, please callthe Plan Checker Coordinator listed above. * For plan check status, please call .760].777-7L25 GORRECTIONS Plan Check No.: FHPR2020-0001 Structural Review Only Type of Construction: Phone:1-213-375-87rt4 t+ri OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org October 19, 2020 Darkjian Associates 2411 E Foothill Blvd Pasadena, CA 91107 Re: High-Pile / Rack Storage – 1st Fire Plan Review – AMERICAN TIRE DEPOT FHPR2020-0001 The plans and report you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and require the following corrections: 1) La Quinta Building Department: a. This is a Fire Application that Building does not review for approval. Applicant to separately submit for a permit type of “Structure Other Than Building” for review and approval of proposed scope of work. 2) Structural Comments (By HRGreen): a. Have structural engineer of record sign and date all sheets. b. Update all codes referenced to current codes including 2019 CBC. c. See green-line notes on returned documents for additional details. 3) Fire Comments: a. La Quinta Municipal Code has amended the CA Fire Code section 3204.2.1 to require a Technical Report from a Fire Protection Engineer. Plans and document shall be stamped and signed by a CA registered Fire Protection Engineer. b. Rack Locations as detailed in the submitted documents is not consistent with present conditions. i. Confirm rack orientation and locations. c. Confirm all dimensions of rack assembly system. d. Confirm dimensions of maintained aisles. Be clear that minimum aisle dimensions is maintained when considering tire on tread protrusions from rack assembly. e. Technical Report elements shall adequately reference all Code and Standard citations. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org December 7, 2020 Darkjian Associates 2411 E Foothill Blvd Pasadena, CA 91107 Re: High-Pile / Rack Storage – 2nd Fire Plan Review – AMERICAN TIRE DEPOT FHPR2020-0001 / 79762 HIGHWAY 111, LA QUINTA, CA 92253 The plans and report you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and require the following corrections: 1) Fire Comments (Sheet 2 – Floorplan and Elevation details): a. The Floorplan detail no longer identifies the location and dimension of the (3) existing partition (screen) walls that are in place approximately 2’2” off the exterior wall windows. In communication with Bedros Darkjian, there is no current plan to remove or modify these partition walls. b. The location of the East partition wall creates a too narrow aisle passageway, therefore creating (2) dead-end aisles in the rack assembly area. The length of the proposed rack assembly scaled out to 58-feet. CFC 3206.10.3 prohibits dead-end aisles from exceeding 50- feet. c. In the Elevation Detail, and as commonly observed in this tire-rack storage assembly, a tire- in-rack protrusion is detailed. Current detail estimates a 6-inch tire-in-rack protrusion, which is believed to be a minimum dimension and not an average expected. Analyses of the largest diameter tire to be commonly stored should be considered to better identify expected protrusion into the aisle space. d. Tire-rack storage assemblies shall be installed an appropriate distance from the other, with consideration to the dimensions of protrusion likely to be observed, in order to maintain a minimum 44-inch clear aisle width dimension. (CFC 3206.10.1.1) 2) *The provided High-Piled Storage Technical Report as signed by FPE Steven Biship (FP-1556) has been stamped approved by La Quinta Office of the Fire Marshal. 3) **Building Department is reviewing Structural separately under permit BOTH2020-0009. Plans and details shall match appropriately. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org February 17, 2021 AVA Prop Inv. 14407 Alondra Blvd. La Mirada, CA 90638 Re: High-Pile / Rack Storage - Fire Plan Review – AMERICAN TIRE DEPOT FHPR2020-0001 / 79840 HIGHWAY 111, LA QUINTA, CA 92253 The building plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Approval of the Building Permit (BOTH2020-0009) shall be granted by the La Quinta Building Official. Plans shall be consistent with the Fire Permit plans and details. The following inspections and tests shall be completed: 1. Bare-rack Inspection – prior to any commodities being stored – Confirm aisle spacing, flue space maintenance, Storage-height limitation signage and rack anchoring. 2. Final/Commodity Inspection – Confirm type(s) of commodities in compliance with approved Technical Report and storage-heights and suppression system is as approved on plans. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79840 HIGHWAY 111 (79762/APN:600010023) PERMIT#: FHPR2020-0001 DATE ISSUED: 2/17/2021 DESCRIPTION: HIGH PILE – RUBBER TIRE STORAGE CONTRACTOR: AMERICAN TIRE DEPOT HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.