Loading...
FM2021-0004ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT MSA CONSULTING - JULIANNE LEVINE 34200 Bob Hope Drive RANCHO MIRAGE CA 92270 (760)320-9811 arowe@msaconsultingi nc.com CONTRACTOR MSA CONSULTING - ERIN BOHLIN 34200 Bob Hope Drive RANCHO MIRAGE CA 92270 (760)320-9811 ebohlin@msaconsultin ginc.com OWNER SLF ADAMS STREET, LA QUINTA LLC 2 PARK PLAZA STE 200 IRVINE CA 92614 (760)320-9811 CMCLARAND@SHOPOF F.COM CONDITIONS Description: VEHICULAR GATE SUBMITTAL Type: FIRE MISCELLANEOUS (WEB)Subtype: Status: APPROVED Applied: 10/4/2021 ECON Parcel No: 600340048 Site Address: 47260 ADAMS ST LA QUINTA,CA 92253 Approved: 12/21/2021 KHET Subdivision: Block: Lot: 1 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $100,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Per comments on Planning Doc (FLP2021-0006), submitting separately for review of vehicular gate to Fire ONLY. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE STAFF - PER HOUR 101-0000-42420 0.5 $83.50 $0.00 Printed: Friday, February 24, 2023 10:33:44 AM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FM2021-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/4/2021 Etrakit Contractor LANDSCAPE CONSTRUCTION DOC SET 2021-09-28 2609 Centre at La Quinta - Landscape Construction Sheets_CVWD Approved.pdf 1 DOC 12/7/2021 Etrakit Contractor FM2021-0004 - 2ND SUBMITTAL 2021-11-29 2609 Centre at La Quinta - Landscape Construction Sheets.pdf 1 DOC 12/7/2021 Etrakit Contractor FM2021-0004 - RESPONSE TO COMMENTS 2021-11-29 2609 Response To Comments Ltr.pdf 1 BOND INFORMATION INSPECTIONS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (1 WK)KOHL HETRICK 11/8/2021 11/16/2021 11/17/2021 REVISIONS REQUIRED SEE ATTACHMENTS SEE PLAN COMMENTS LOCATED IN ATTACHMENTS 2ND FIRE (1 WK)KOHL HETRICK 12/7/2021 12/14/2021 12/21/2021 APPROVED SEE ATTACHMENTS PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE STAFF - PER HOUR 101-0000-42420 0.5 $83.50 $0.00 FIRE STAFF - PER HOUR 101-0000-42420 1 $167.00 $0.00 Total Paid for FIRE FEES: $334.00 $0.00 TOTALS:$334.00 $0.00 Printed: Friday, February 24, 2023 10:33:44 AM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FM2021-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/23/2021 KOHL HETRICK FM2021-0004 - 1ST REVIEW - PLAN CORRECTIONS.pdf FM2021-0004 - 1ST REVIEW - PLAN CORRECTIONS.pdf 1 DOC 12/21/2021 KOHL HETRICK FM2021-0004 - APPROVED GATE PLANS.pdf FM2021-0004 - APPROVED GATE PLANS.pdf 1 DOC 12/21/2021 KOHL HETRICK FM2021-0004 - COA AND JOB CARD.pdf FM2021-0004 - COA AND JOB CARD.pdf 1 Printed: Friday, February 24, 2023 10:33:44 AM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FM2021-0004 CVWD ENGINEERING APPROVALPREPARED FOR:THE CENTRE AT LA QUINTAINDEX:PROJ. NO.:ISSUED DATE:PROJECT NO.:PROJECT NAME:2609REVISIONS/SUBMITTALSTHE CENTRE AT LA QUINTAVICINITY MAP:CONSULTANTS:STANDARD SYMBOLS AND ABBREVIATIONSSCORE JOINT+12"ALIGNELEVATION DETAILHDRTYPDNRDETAIL NUMBERLIMIT OF WORKMOUNDING (NOT TO EXCEED 3:1)SHEET MATCHLINEHIGH POINT OF MOUND (IN INCHES)KEYNOTE, SEE MASTER LIST OF SHEETSHEET NUMBEREXPANSION JOINTPOINT OF BEGINNING FOR DIMENSIONINGDIRECTION OF SLOPE. % MIN. ON HARDSCAPELOW POINTHEIGHTDIAMETERCONTINUOUSSIMILARPACDECOMPOSED GRANITEEQWSMINCOLHPLPDIACONTHTSIMO.CDGLPLTWTYPICALPLANTING AREACENTER LINEPROPERTY LINERADIUSEQUALWATER SURFACE LEVELALIGN ACCORDINGLYHEADER BOARDSPECIFICATIONS FOR THIS PROJECT ARE TO BE INCLUDED INELECTRONIC BOOK FORMAT. IF A COPY OF THE SPECIFICATIONS WASNOT RECEIVED, PLEASE CONTACT THE LANDSCAPE ARCHITECT OFRECORD FOR A COPY.DOWN RISERSMINIMUMCOLUMNHEIGHT POINTTOP OF WALL (AS MEASUREDFROM THE ADJACENT FINISH GRADE)ON CENTER811LANDSCAPEARCHITECTTWO WORKING DAYS BEFORE YOU DIGNORTHUNDERGROUNDSERVICE ALERTRGA PROJECT MANAGER:SPECIFICATIONS:CONSTRUCTION PLANCONSTRUCTION DETAILSIRRIGATION PLANIRRIGATION DETAILSPLANTING & LIGHTING PLANPLANTING DETAILSLIGHTING DETAILS260903/25/2021CITY COMMENT16/14/21EW L-1.00 THRU L-1.07L-2.00 THRU L-2.03L-3.00 THRU L-3.16L-4.00 THRU L-4.01L-5.00 THRU L-5.13L-6.00L-7.00ADAMS STTRACT 37359APN 600-340-048-1Shopoff34200 BOB HOPE DRIVE, RANCHO MIRAGE, CA 92270760.320.9811 MSACONSULTINGINC.COMWATER CONSERVATION STATEMENT:TOM MILLERtmiller@msaconsultinginc.com.comATTN: Torry Lozano2 Park Plaza, Suite 700Irvine, CA 92614E: tlozano@shopoff.com REAR YARD TYPICAL ENLARGEMENTS AREFOUND ON SHEETS L-X.09 THRU L-X.13WATER CALCULATIONSFOUND ON SHEETS L-3.14THRU L-3.16WASHINGTON STADAMS STDUNE PALMS RDJEFFERSON STAVENUE 48HWY 111SITECITY COMMENT : PLANTING RE UTILITIES29/28/21EBCITY COMMENT : VINES IN RETENTION BASIN310/19/21EBMAILBOX ADDITIONS411/17/21EBAPPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST12/21/2021 3:33:39 PMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FM2021-0004VEHICLE GATES - FIRE ACCESSKohl HetrickReason: I am approving this documentContact Info: 760-409-5109 PROD. 1-2APROD. 1-4APROD. 1-2APROD. 1-3APROD. 1-4APROD. 1-3A PROD 2-1CPROD 2-1CPROD 2-2APROD 2-4APROD 2-3APROD 2-3APROD. 1-1XPROD. 1-1XPROD. 1-3APROD. 1-3APROD. 1-4APROD. 1-1XPROD. 1-1XPROD. 1-4APROD. 1-3APROD. 1-2APROD. 1-4APROD. 1-1APROD. 1-3APROD. 1-2APROD. 1-4APROD. 1-1APROD. 1-2APROD. 1-4APROD. 1-3APROD. 1-1APROD. 1-4APROD. 1-3APROD. 1-3APROD. 1-2APROD. 1-4APROD. 1-1APROD. 1-2APROD. 1-4APROD. 1-3APROD. 1-1APROD. 1-3APROD. 1-2APROD. 1-2APROD. 1-4APROD. 1-3APROD. 1-1APROD. 1-4APROD. 1-2APROD. 1-3APROD. 1-4APROD. 1-1XPROD. 1-1XPROD. 1-4APROD. 1-3APROD. 1-2APROD. 1-1XPROD. 1-1XPROD. 1-3APROD. 1-4APROD. 1-2APROD. 1-2APROD. 1-4APROD. 1-3APROD. 1-2A PROD. 1-3A PROD. 1-4A PROD. 1-1A PROD 2-4APROD 2-1CPROD 2-1CPROD 2-2APROD 2-3APROD 2-3APROD 2-4APROD 2-1CPROD 2-1CPROD 2-3APROD 2-3APROD 2-2APROD 2-2APROD 2-1CPROD 2-1CPROD 2-4APROD 2-3APROD 2-3APROD 2-1CPROD 2-1CPROD 2-2APROD 2-4APROD 2-3APROD 2-3APROD 2-1CPROD 2-1CPROD 2-2APROD 2-4APROD 2-3APROD 2-1CPROD 2-1CPROD 2-2APROD 2-4APROD 2-3APROD 2-3APROD 2-3APROD 2-3APROD 2-4APROD 2-2APROD 2-1CPROD 2-1CPROD 2-3APROD 2-3APROD 2-3APROD 2-4APROD 2-2APROD 2-1CPROD 2-1CPROD 2-3APROD 2-3APROD 2-4APROD 2-2APROD 2-1CPROD 2-1CPROD 2-3APROD 2-3APROD 2-4APROD. 1-2APROD. 1-2APROD. 1-2APROD. 1-1XPROD. 1-1X176124 PLAYSENSE DESIGN 30 164075 DOUBLE BOBBLE SPRING RIDER PRECISION CAP 6x2x16 ACCENT BLOCK SPLIT FACE BAND 8X8X16 PRECISION CMU BLOCK 8X8X16 VARIESSEE CIVIL PLAN2"3'-6"1'MIN8X8X16 SCORE LINE BLOCK 2" SQ TUBE POST @ 8' O.C. 1 2" SQ TUBE PICKET @4" O.C 1" SQ TUBE RAILING 5'-9"8X8X16 SCORE LINE BLOCK 6X2X16 WALL CAP 1'3"2'4"4'-9"5"2" SQ TUBE POST @ 8' O.C. 1 2" SQ TUBE PICKET @4" O.C 1" SQ TUBE RAILING 1" SQ TUBE RAILING 6'5'-6"DIMENSION KEYNOTES NORTH CONSTRUCTION PLAN6/14/21 9/27/21 10/19/21 - - - - 1 CITY COMMENTS 2 3 - - CITY COMMENTS: PLANTING FIRE DEPT COMMENTS: PLANTING - - - - - - EW EB EB - - -PROJECT:SHEET TITLELANDSCAPE ARCHITECT: PROJECT MANAGER: DRAWN: CHECKED: PROJ. N0. DATE: SCALE: REVISIONS:INIT. SHEET N0: TM TM 2609 3/25/2021LA QUINTA, CA- - -- - - --- CONTINGENCY NOTE: LANDSCAPE CONTRACTOR SHALL INCLUDE A CONTINGENCY EQUAL TO 10% OF THEIR BID TO PROVIDE ADDITIONAL WORK OR MATERIALS DURING CONSTRUCTION IF REQUESTED BY OWNER OR LANDSCAPE ARCHITECT.  ANY CONTINGENCY FUNDS NOT USED SHALL BE REMITTED TO OWNER.   UTILITY EASEMENT NOTE: ALL UTILITY EASEMENTS ARE TO REMAIN FREE OF ANY TREES, PLANTINGS OR STRUCTURES THAT WILL CAUSE A PROBLEM FOR THE UTILITY COMPANY TO ACCESS OR TO USE THAT DEDICATED PORTION OF THE PROPERTY. THE UTILITY COMPANIES ARE WITHIN THE LAW TO DEMOLISH OR DAMAGE ANYTHING THAT IS LOCATED WITHIN THE UTILITY EASEMENT THAT PREVENTS ACCESS AND USE OF THE DEDICATED PORTION OF THE PROPERTY IF NECESSARY.  UTILITY COMPANIES HAVE THE RIGHT TO ACCESS THEIR FACILITIES AT ANY TIME FOR MAINTENANCE AND EMERGENCY PURPOSES.  IF NECESSARY, THE UTILITY MAY REMOVE LANDSCAPING, STRUCTURES OR ANYTHING ELSE BLOCKING ACCESS TO THEIR FACILITIES AT OWNER EXPENSE.  UTILITIES ARE NOT RESPONSIBLE FOR REPLACING ANY PLANTING WITHIN THEIR EASEMENT.  LANDSCAPE ARCHITECTS A DESIGN STUDIO OF MSA CONSULTING, INC . > LANDSCAPE ARCHITECTURE > PLANNING > CIVIL ENGINEERING > LAND SURVEYING 34200 BOB HOPE DRIVE, RANCHO MIRAGE, CA 92270 760.320.9811 MSACONSULTINGINC.COM MSA CONSULTING, INC. -THE CENTRE AT LA QUINTAGRAPHIC SCALE SCALE: 1" = 50'-0" GRAPHIC SCALE 100'025'50'150' L-1.00 - 1"=50'-0" W1 PA 1.02A 1.02C 1.02D 1.02B 1.02F 1.02 1.01B W2 F2 F2 F3 P1P1 P1 P1 P2 P2 P3 P3 P2 P4P5 PA PA PA PAPA PA PA PA PA PA PA PA PA PA PA P1 P2 1 2 2 2 5 1 1.01A 1.02E 1.04 1.05 P1 LA QUINTA DRIVEADAMS STREETPERIMETER WALL 6' HIGH 8X8X16 PRECISION BLOCK W/ 2X8X16 WALL CAP BY ORCO. STACK PATTERN. SEE CIVIL PLAN FOR RETAINING CONDITION OCCURS 6' HIGH FENCE. FENCE POST @ 8' O.C. 3'-6" HIGH FENCE ON RETAINING WALL 8X8X16 503 SCORE ONE SIDE PRECISION BLOCK BY ORCO. STACK BOND PATTERN.  GARDEN WALL 5'-9" HIGH 8X8X16 503 SCORE BOTH SIDE PRECISION BLOCK BY ORCO. STACK PATTERN. SEE CIVIL PLAN FOR RETAINING CONDITION OCCURS 1/2" = 1'-0"1/4" = 1'-0" 1/4" = 1'-0" FINISH: PRECISION COLOR : SOURDOUGH(ORCO) MORTAR: MATCH FINISH: SPLIT FACE COLOR : SOURDOUGH(ORCO) MORTAR: MATCH FINISH: PRECISION COLOR : SOURDOUGH(ORCO) MORTAR: MATCH 1/4" = 1'-0" FINISH: PRECISION COLOR : SOURDOUGH(ORCO) MORTAR: MATCH NOTES: 1.FOOTING SIZE AND REINFORCING FOR BIDDING PURPOSES ONLY. IF STRUCTURAL DESIGN IS REQUIRED, THAT SHALL BE PROVIDED BY A LICENSED STRUCTURAL ENGINEER 2.CMU MANUFACTURE: ORCO BLOCK (760-347-3245) 5 24 W1. PERIMETER WALL W2. GARDEN WALL F2. POOL FENCEF1. FENCE ON RETAINING WALL COLOR: DUNN EDWARD DET681 MODERN CLASS SEMI-GLOSS ENAMEL 19 23 (1) 16 CMPRT CBU 23 (1) LARGE PARCEL LOCKER 23(1) 8 CMPRT CBU (1) 13 CMPRT CBU 23 (1) 12 CMPRT CBU (1) 8 CMPRT CBU (1) 13 CMPRT CBU 2323 (1) 8 CMPRT CBU (2) 12 CMPRT CBU 23(2) 13 CMPRT CBU (1) 16 CMPRT CBU 8'-9"2'-6"3'-2"2'-6"3'-3"2'-6"2'-6" 22'19'-3"22'6'5'4'2'R40'PROD 2-4A5'37'5'3'-9"6'-9" 16'-6"6'-9"4'-6"5'-3"1 3'-3"ALIGN W/ STRUCTURE/OPENING ALIGN/CENTER ON STRUCTURE, WALL OR OPENING ALIGN CONTROL JOINTS I CONC-SLAB W/ RADIUS POINT OF CURB 1 2 DIMENSION KEYNOTES CONSTRUCTION PLAN6/14/21 9/27/21 10/19/21 - - - - 1 CITY COMMENTS 2 3 - - CITY COMMENTS: PLANTING FIRE DEPT COMMENTS: PLANTING - - - - - - EW EB EB - - -PROJECT:SHEET TITLELANDSCAPE ARCHITECT: PROJECT MANAGER: DRAWN: CHECKED: PROJ. N0. DATE: SCALE: REVISIONS:INIT. SHEET N0: TM TM 2609 3/25/2021LA QUINTA, CA- - -- - - --- CONTINGENCY NOTE: LANDSCAPE CONTRACTOR SHALL INCLUDE A CONTINGENCY EQUAL TO 10% OF THEIR BID TO PROVIDE ADDITIONAL WORK OR MATERIALS DURING CONSTRUCTION IF REQUESTED BY OWNER OR LANDSCAPE ARCHITECT.  ANY CONTINGENCY FUNDS NOT USED SHALL BE REMITTED TO OWNER.   UTILITY EASEMENT NOTE: ALL UTILITY EASEMENTS ARE TO REMAIN FREE OF ANY TREES, PLANTINGS OR STRUCTURES THAT WILL CAUSE A PROBLEM FOR THE UTILITY COMPANY TO ACCESS OR TO USE THAT DEDICATED PORTION OF THE PROPERTY. THE UTILITY COMPANIES ARE WITHIN THE LAW TO DEMOLISH OR DAMAGE ANYTHING THAT IS LOCATED WITHIN THE UTILITY EASEMENT THAT PREVENTS ACCESS AND USE OF THE DEDICATED PORTION OF THE PROPERTY IF NECESSARY.  UTILITY COMPANIES HAVE THE RIGHT TO ACCESS THEIR FACILITIES AT ANY TIME FOR MAINTENANCE AND EMERGENCY PURPOSES.  IF NECESSARY, THE UTILITY MAY REMOVE LANDSCAPING, STRUCTURES OR ANYTHING ELSE BLOCKING ACCESS TO THEIR FACILITIES AT OWNER EXPENSE.  UTILITIES ARE NOT RESPONSIBLE FOR REPLACING ANY PLANTING WITHIN THEIR EASEMENT.  CVWD NOTE: NO PERMANENT STRUCTURES OR TREES WITHIN CVWD OR USBR EASEMENTS. CVWD WILL NOT BE RESPONSIBLE FOR CHANGE OR REPLACEMENT OF ANY SURFACE IMPROVEMENTS,INCLUDING BUT NOT LIMITED TO DECORATIVE CONCRETE, LANDSCAPING, CURB, GUTTER, SIDEWALKS,PLANTERS, GATES AND RELATED IMPROVEMENTS INSTALLED WITHIN CVWD AND /OR USBR EASEMENT LANDSCAPE ARCHITECTS A DESIGN STUDIO OF MSA CONSULTING, INC . > LANDSCAPE ARCHITECTURE > PLANNING > CIVIL ENGINEERING > LAND SURVEYING 34200 BOB HOPE DRIVE, RANCHO MIRAGE, CA 92270 760.320.9811 MSACONSULTINGINC.COM MSA CONSULTING, INC. -THE CENTRE AT LA QUINTAL-1.01 - 1"=20'-0" L-1.01 A L-1.01 B L-1.02 A L-1.02 B L-1.02 C L-1.02 D L-1.02 E L-1.02 F L-1.03 L-1.04 L-1.05 LA QUINTA DRIVEADAMS STREETNORTH 20'0 GRAPHIC SCALE 5'10' SCALE: 1" = 10'-0" 30' PA PA PA PA PA PA PA PA PA PA PA PA PA P3 P3 P1 3 W1 W2 W1 P2 1 2 1 P2 P1 P1 P1 P1 2 2 1 W1 W2 W1 AREA A AREA B LA QUINTA DRIVEPA PA GATE OPERATION EQUIPMENT LOCATION, SPECIFICATIONS, & ELECTRICAL CONNECTION TO BE COORDINATED WITH OWNER AND PROVIDED BY GATE CONTRACTOR. GATE OPERATION EQUIPMENT LOCATION, SPECIFICATIONS, & ELECTRICAL CONNECTION TO BE COORDINATED WITH OWNER AND PROVIDED BY GATE CONTRACTOR. 11 2 3 4 5 6 2" SQ. TUBE STEEL FRAME HINGE DESIGN BY GATE FABRICATOR 9 7 ADJACENT 8X8X16 BLOCK WALL PERFORATED METAL 3" SQ. STEEL POST. ATTACH TO BLOCK WALL W/ 1 2" DIAM. WELDED STUDS @ 16 O.C. WELD END CAP TO TOP OF CHANNEL NOTE 1.WELD ALL CONNECTIONS & GRIND SMOOTH. FINISH ALL METAL SURFACES W/1 COAT OF ZINC-CHROMATE PRIMER & 2 COATS OF EXTERIOR GRADE / SEMI-GLOSS ENAMEL. COLOR TO BE DUNN EDWARDS 681 CONTRACTOR TO SUBMIT SHOP DRAWINGS TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO FABRICATION. 2.ALL STEEL TO BE GALVANIZED 3.PILASTER FOUNDATION BY OTHERS PEDESTRIAN GATE 1/2" = 1'-0"- 8 PRECISION COLUMN BLOCK 16X8X16 FINISH: SPLIT FACE COLOR: SOURDOUGH PRECISION CAP 4X2X16 FINISH/COLOR MATCH COLUMN 9 8 PLAN VIEW a SECTION a - a 6'8"6" 7 FG 8 14 GAGE 2" WIDE STEEL LOCK BOX, 2 3/4" BACKSET FLAT SURFACE W/ ASTRAGAL #K-BXSGL234-2W BY KEEDEX. EXTERIOR GRADE LOCK SET TO BE MOUNTED AT 42" ABOVE ADJACENT FINISH GRADE. CONTRACTOR RESPONSIBLE TO PROVIDE SPECIFICATION TO OWNERSHIP PRIOR TO INSTALLATION. 6 5 134 2 29 3"5'-9"5'-0" SITE VERIFIED 2'-9" ELEVATION 10 #4 HORIZONTAL 10 11 11 #4 32" O.C. VERTICAL 12 CONCRETE FOOTING BY OTHERS 12 RECESSED 3200 SERIES KNOX BOX SHALL BE MOUTNED TO THE RIGHT OF THE GATE SO THE TOP IS 6FT IN HEIGHT FACING THE STREET. SEE GATE/FIRE DEPARTMENT NOTES BELOW. AN ELECTRONIC KNOX BOX KEY SWITCH IS REQUIRED ON THE MONUMENT. VISIT WWW.KNOXBOX.COM TO ORDER THE KNOX BOX KEY SWITCH. RECESSED 3200 SERIES KNOX BOX SHALL BE MOUTNED TO THE RIGHT OF THE GATE SO THE TOP IS 6FT IN HEIGHT FACING THE STREET. SEE GATE/FIRE DEPARTMENT NOTES BELOW. AN ELECTRONIC KNOX BOX KEY SWITCH IS REQUIRED ON THE MONUMENT. VISIT WWW.KNOXBOX.COM TO ORDER THE KNOX BOX KEY SWITCH. 1 245 11 2 3 4 5 6 67 7 10'-10" SITE VERIFIED 1'-4"5'-6"7"HINGE DESIGN BY GATE FABRICATOR 9 10 10 9 VEHICULAR GATE 1/2" = 1'-0"- PERFORATED METAL FOR GATE INFILL PANEL EQUAL TO QUALITY 3/8" SQUARE ON 1/2" CENTER PERFORATED METAL PLAN STEEL WITH 56% OPENING BY MCNICHOLS. - b 3" SQ. TUBE STEEL FRAME. 1"X2" TUBE STEEL FRAME 1"x2" RECTANGULAR PICKETS @4" O.C. W/1" FACING OUT A. MAIN ENTRY AUTOMATIC - HALF B. SECONDARY ENTRY MANUAL OPERATION - HALF 8 1'-2"3 6'-0"1 24567 18'-10" SITE VERIFIED 1'-1"5'-6"7"10 9 1'-2"3 6'-0"4 1/2" x 4 1/2" SINGLE ACTION SPRING HINGES SELF CLOSING (MIN. OF 3) PER GATE EQUAL TO PR(S) CAL ROYAL STAINLESS STEEL 4 - 1/2" x 4" STRONG-TIE TITEN HD SCREW STEEL ANCHOR BY SIMPSON COLUMN. SEE DETAIL L, SECTION a-a ADJACENT BLOCK WALL. SEE DETAIL W1 SHEET L-1.00 6X8 STEEL TUBE POST W/ STUD BOLTS SET W/ CMU 11 FOOTING BY OTHERS 11 11 1213567 10'-0" SITE VERIFIED 5'-6"3"10 9 C. MAINTENANCE ENTRY MANUAL OPERATION-HALF6'-0"12 2" SQ TUBE STEEL FRAME 13 3/4" SQ TUBE PICKETS @4" O.C. 12135616 7'-6" SITE VERIFIED 5'-6"3"D. MAINTENANCE ENTRY MANUAL OPERATION - HALFSEE CIVIL PLANSECTION b-b 14 1" SQ TUBE PICKETS @4" O.C. 15 15 1515 16 ADJACENT RETAINING WALL & FENCE COMBINATION. SEE DETAIL F1, SHEET L-1.00 11 11 GENERAL GATE NOTES: 1. GATE CONTRACTOR TO SUPPLY KNOX KEY BOX LOCATION AND SPECIFICATIONS PER FIRE DEPARTMENT REQUIREMENTS. 2. WELD ALL CONNECTIONS & GRIND SMOOTH. ALL STEEL TO BE HOT DIPPED GALVANIZED. FINISH ALL METAL SURFACES W/1 COAT OF ZINC-CHROMATE PRIMER & 2 COATS OF SEMI-GLOSS EXTERIOR GRADE ENAMEL. COLOR TO BE SELECTED BY OWNER. 3. CONTRACTOR TO SUBMIT SHOP DRAWINGS TO LANDSCAPE ARCHITECT FOR APPROVAL OF GATES PRIOR TO FABRICATION. 4. ALL STRUCTURAL DETAILS TO BE PROVIDED BY CALIFORNIA LICENSED STRUCTURAL ENGINEER. 5. GATE WIDTHS TO BE DETERMINED AFTER WALL CONSTRUCTION. CONTRACTOR TO FIELD VERIFY PRIOR TO CONSTRUCTION OF GATES. GATE/FIRE DEPARTMENT NOTES: 1. THE RESIDENTIAL ENTRY GATES WILL BE INSTALLED IN ACCORDANCE WITH UL 325, ASTM F2200 STANDARDS, 2019 CALIFORNIA FIRE CODE. CFC 503.6 2. KNOX BOXES SHALL BE MOUNTED TO THE RIGHT OF THE GATE, SO THE TOP IS 6 FEET IN HEIGHT FACING THE STREET. VISIT WWW.KNOXBOX.COM TO ORDER THE KNOX BOX. PROVIDE A SET OF KEYS WITH IDENTIFICATION TAGS FOR THE VEHICULAR EMERGENCY ACCESS GATES WHICH WILL BE STORED INSIDE THE KNOX BOXES FOR FIRE DEPARTMENT ACCESS. CFC 506.1. 3. THE GATE OR ARM, WHEN FULLY OPENED SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 24 FEET FOR SINGLE ROADWAY GATES. SUB-DIVISIONS MAY HAVE A DIVIDED ENTRANCE AND EXIT GATES. THE ENTRANCE SIDE SHALL HAVE A CLEARANCE OF 16 FEET CLEAR WIDTH, THE EXIT SIDE 16 FEET CLEAR WIDTH. IF A BOULEVARD IS PRESENT, THE DIMENSIONS INCREASE TO 24 FEET ON BOTH SIDES. CITY OF INDIO ORDINANCE, CHAPTER 5 SECTION 503.2.1 4. NOTHING IN LA QUINTA FIRE DEPARTMENT’S REVIEW SHALL BE CONSTRUED AS ENCOMPASSING STRUCTURAL INTEGRITY. REVIEW OF THIS PLAN DOES NOT AUTHORIZE OR APPROVE ANY OMISSION OR DEVIATION FROM ALL APPLICABLE REGULATIONS. FINAL FIELD INSPECTION SHALL VERIFY ALL REQUIREMENTS. ALL QUESTIONS REGARDING THE MEANING OF THE CODE REQUIREMENTS SHOULD BE REFERRED TO THE FIRE PREVENTION BUREAU AT 760-564-2122. 5. A FINAL INSPECTION IS REQUIRED BY THE FIRE DEPARTMENT WITH GATE CONTRACTOR PRESENT. INSPECTIONS CAN BE SCHEDULED BY CALLING 760-347-0756 A MINIMUM OF 48 HOURS IN ADVANCE OF THE INSPECTION DATE. HEAVY DUTY EXTERIOR GRADE LOCK TO BE PROVIDED BY GATE CONTRACTOR. SEE FIRE DEPARTMENT NOTES FOR FURTHER LOCK INFORMATION. GATE/FIRE DEPT NOTES CONTINUED: 6. AN APPROVED OPTICAL TRAFFIC PREEMPTION DEVICE (TPD) MUST BE INSTALLED ON ALL AUTOMATICALLY OPERATED GATES. THESE DEVICES MUST BE OF DIGITAL DESIGN. ANALOG UNITS ARE NOT ACCEPTABLE. BI-DIRECTIONAL OR MULTIPLE DEVICES MAY BE NEEEDED IN ORDER TO ACHIEVE THE DESIRED PERFORMANCE WHEN ENTRY CONFIGURATIONS ARE OF A MORE COMPLEX NATURE. 7. ACTIVATION OF THE TPD SHALL RESULT IN THE GATE REMAINING IN THE OPEN POSITION FOR A MINIMUM OF 30 SECONDS TO ALLOW FIRE DEPARTMENT UNITS TO GAIN UNRESTRICTED ENTRY AFTER WHICH TIME THE GATE SHALL AUTOMATICALLY RESET BACK TO NORMAL OPERATION. 6 591'-4"1 4 CONCRETE FOOTING BY OTHERS COMPACTED SUBGRADE #4 HORIZONTAL #4 32" O.C. VERTICAL 2"7 8 5 6 FG SIGN MONUMENT 1/2" = 1'-0"- 2 6 7 8 11 2 3 4 5 PRECISION CMU CAP 6x2x16 4 2'-0"6'-0"8"8"8'-0" LA QUINTA 2 3 4 NOTE: 1.SIGN DETAILS BY SIGN COMPANY , PER SEPARATED PERMIT 2.REFER TO DETAIL W1, SHEET L-2.00 FOR CONSTRUCTION DETAIL OF WALL. 3.FONT STYLE, SIZE, MATERIALS AND MOUNTING DETAILS PER SIGN CONTRACTOR. 6" 9 9 1 EQEQ PRECISION CMU CAP 8X8X16 ACCENT BLOCK SPLIT FACE BAND 8X8X16 2 3 9 SECTION a - a ELEVATION LETTER "LA QUINTA" 6" DEEP FREE STANDING LETTERS "CENTRE"CONSTRUCTION DETAILSL-2.01 PER DETAIL 6/14/21 9/27/21 10/19/21 - - - - 1 CITY COMMENTS 2 3 - - CITY COMMENTS: PLANTING FIRE DEPT COMMENTS: PLANTING - - - - - - EW EB EB - - -PROJECT:SHEET TITLELANDSCAPE ARCHITECT: PROJECT MANAGER: DRAWN: CHECKED: PROJ. N0. DATE: SCALE: REVISIONS:INIT. SHEET N0: TM TM 2609 3/25/2021LA QUINTA, CA- - -- - - --- LANDSCAPE ARCHITECTS A DESIGN STUDIO OF MSA CONSULTING, INC . > LANDSCAPE ARCHITECTURE > PLANNING > CIVIL ENGINEERING > LAND SURVEYING 34200 BOB HOPE DRIVE, RANCHO MIRAGE, CA 92270 760.320.9811 MSACONSULTINGINC.COM MSA CONSULTING, INC. -THE CENTRE AT LA QUINTAEW K L -- PERFORATED METAL DESIGNER PERFORATED, SQUARE, LATTICE 0853, ALUMINUM, ALLOY 3003-H14, .1250" THICK (8 GAUGE), 1/2" SQUARE ON 11/16" STRAIGHT CENTERS, 53% OPEN AREA ENAMEL DUNN EDWARD DET681 MODERN CLASS SEMI-GLOSS ENAMEL NELEVATION NTSM SECONDARY ENTRY MAIN ENTRY 1 Hetrick, Kohl@CALFIRE From:Hetrick, Kohl@CALFIRE Sent:Tuesday, April 18, 2023 1:00 PM To:David Kinnett Cc:Jose Delgado; Rojas, Leilani@CALFIRE Subject:Solterra Gates - Call Box Location Attachments:FSINSP2022-0010 - 9-20-2022 - INSPECTION REPORT - FLAT.pdf; FM2021-0004 - COA AND JOB CARD.pdf; FM2021-0004 - APPROVED GATE PLANS.pdf Dave, AƩached is the historical Fire InspecƟon report associated with Fire Access and Water verificaƟon. Also the CondiƟons of Approval LeƩer & Job Card, as well as the approved gate plans for referenced permit FM2021-0004. The permit was approved on 12/21/2021 and fees are sƟll due for payment. In regards to the CallBox locaƟon for the main entry: Thank you, KOHL HETRICK Fire Safety Specialist / Office of the Fire Marshal City of La Quinta & County Strategic Planning CAL FIRE/Riverside County Fire Department Desk: 760-777-7074 | Mobile: 760-409-5109 Inspection Hotline: 760-777-7131 78495 Calle Tampico, La Quinta, CA 92253 kohl.hetrick@fire.ca.gov | www.rvcfire.org Sch: Mon-Thurs Leadership, Competence, Integrity, Safety, Customer Service The Office of the County Fire Marshal is committed to facilitating fire and life safety solutions by empowering its employees to serve our community through innovation and partnership. RESPONSE TO COMMENTS DATE: 29 November 2021 PROJECT: Centre at La Quinta: PROJECT NO: 2609 SUBJECT: Main & Emergency Entry Gates Fire Submittal: Comments Re Eqpmt Description of review/agency comments 1. Redlines on cover sheet to indicate need to remove water conservation statement and CVWD approval stamp/record. a. Response: Water Conservation statement and CVWD Landscape Approval indication are removed from this set. 2. Main Entry, L-1.01: Identify location of KNOX key switch and provision of OPTICOM IR Receiver for rapid Fire Access through the gate. Preference of KNOX key switch on Pedestal. a. Response: Official design and technical information to be supplied by Gate Contractor. Knox box proposed location & notes added on Detail M (Elevations), Sheet L-2.01 b. Additional Gate/Fire Dept Notes (6 & 7) regarding TPD added on Detail K, L- 2.01 3. Main Entry, L-1.01: Identify the location, make, model and UL325 compliant electric gate operators. a. Response: Approximate size and location added to plan. Official design and technical information to be supplied by Gate Contractor. 4. Emergency Entry, L-1.01: Identify location of KNOX key switch and provision of OPTICOM IR Receiver for rapid Fire Access through the gate. a. Response: Official design and technical information to be supplied by Gate Contractor. Knox box proposed location & notes added on Detail M (Elevations), Sheet L-2.01 b. Additional Gate/Fire Dept Notes (6 & 7) regarding TPD added on Detail K, L- 2.01 5. Emergency Entry, L-1.01: Identify the location, make, model and UL325 compliant electric gate operators. a. Response: Approximate size and location added to plan. Official design and technical information to be supplied by Gate Contractor. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org December 21, 2021 SLF Adams Street, La Quinta LLC 2 Park Plaza #200 Irvine, CA 92614 Re: Vehicle Gate – Fire Access - Plan Review – THE CENTRE – LA QUINTA FM2021-0004 / ADAMS STREET X SUNFLOWER LANE The plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Gate Clear Opening Width (b) UL325 Listed Electric Gate Operator confirmed (c) KNOX Access (d) Infrared Signal Access – Will need to coordinate Fire Apparatus to perform site visit and operate emergency lights to create the access activation. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: THE CENTRE TM 37359 PERMIT#: FM2021-0004 DATE ISSUED: 12/21/2021 DESCRIPTION: VEHICLE GATES – FIRE ACCESS APPLICANT: SLF ADAMS STREET, LA QUINTA LLC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Vehicle Gate – Fire Access Function test UL325 Listed Elec. Gate Operators Gas/electrical shut-off Infrared Signal Access Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.