FM2021-0004ADDITIONAL SITES
CHRONOLOGY
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT MSA CONSULTING - JULIANNE
LEVINE
34200 Bob Hope Drive RANCHO
MIRAGE
CA 92270 (760)320-9811 arowe@msaconsultingi
nc.com
CONTRACTOR MSA CONSULTING - ERIN BOHLIN 34200 Bob Hope Drive RANCHO
MIRAGE
CA 92270 (760)320-9811 ebohlin@msaconsultin
ginc.com
OWNER SLF ADAMS STREET, LA QUINTA LLC 2 PARK PLAZA STE 200 IRVINE CA 92614 (760)320-9811 CMCLARAND@SHOPOF
F.COM
CONDITIONS
Description: VEHICULAR GATE SUBMITTAL
Type: FIRE MISCELLANEOUS (WEB)Subtype: Status: APPROVED Applied: 10/4/2021 ECON
Parcel No: 600340048 Site Address: 47260 ADAMS ST LA QUINTA,CA 92253 Approved: 12/21/2021 KHET
Subdivision: Block: Lot: 1 Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled:
Valuation: $100,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: Per comments on Planning Doc (FLP2021-0006), submitting separately for review of vehicular gate to Fire ONLY.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
FIRE STAFF - PER HOUR 101-0000-42420 0.5 $83.50 $0.00
Printed: Friday, February 24, 2023 10:33:44 AM 1 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FM2021-0004
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 10/4/2021 Etrakit Contractor
LANDSCAPE
CONSTRUCTION DOC
SET
2021-09-28 2609 Centre
at La Quinta - Landscape
Construction
Sheets_CVWD
Approved.pdf
1
DOC 12/7/2021 Etrakit Contractor FM2021-0004 - 2ND
SUBMITTAL
2021-11-29 2609 Centre
at La Quinta - Landscape
Construction Sheets.pdf
1
DOC 12/7/2021 Etrakit Contractor
FM2021-0004 -
RESPONSE TO
COMMENTS
2021-11-29 2609
Response To Comments
Ltr.pdf
1
BOND INFORMATION
INSPECTIONS
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS REMARKS NOTES
1ST FIRE (1 WK)KOHL
HETRICK 11/8/2021 11/16/2021 11/17/2021 REVISIONS REQUIRED SEE ATTACHMENTS SEE PLAN COMMENTS LOCATED IN
ATTACHMENTS
2ND FIRE (1 WK)KOHL
HETRICK
12/7/2021 12/14/2021 12/21/2021 APPROVED SEE ATTACHMENTS
PARENT PROJECTS
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
FIRE STAFF - PER HOUR 101-0000-42420 0.5 $83.50 $0.00
FIRE STAFF - PER HOUR 101-0000-42420 1 $167.00 $0.00
Total Paid for FIRE FEES: $334.00 $0.00
TOTALS:$334.00 $0.00
Printed: Friday, February 24, 2023 10:33:44 AM 2 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FM2021-0004
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 11/23/2021 KOHL HETRICK
FM2021-0004 - 1ST
REVIEW - PLAN
CORRECTIONS.pdf
FM2021-0004 - 1ST
REVIEW - PLAN
CORRECTIONS.pdf
1
DOC 12/21/2021 KOHL HETRICK
FM2021-0004 -
APPROVED GATE
PLANS.pdf
FM2021-0004 -
APPROVED GATE
PLANS.pdf
1
DOC 12/21/2021 KOHL HETRICK FM2021-0004 - COA
AND JOB CARD.pdf
FM2021-0004 - COA
AND JOB CARD.pdf 1
Printed: Friday, February 24, 2023 10:33:44 AM 3 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FM2021-0004
CVWD ENGINEERING APPROVALPREPARED FOR:THE CENTRE AT LA QUINTAINDEX:PROJ. NO.:ISSUED DATE:PROJECT NO.:PROJECT NAME:2609REVISIONS/SUBMITTALSTHE CENTRE AT LA QUINTAVICINITY MAP:CONSULTANTS:STANDARD SYMBOLS AND ABBREVIATIONSSCORE JOINT+12"ALIGNELEVATION DETAILHDRTYPDNRDETAIL NUMBERLIMIT OF WORKMOUNDING (NOT TO EXCEED 3:1)SHEET MATCHLINEHIGH POINT OF MOUND (IN INCHES)KEYNOTE, SEE MASTER LIST OF SHEETSHEET NUMBEREXPANSION JOINTPOINT OF BEGINNING FOR DIMENSIONINGDIRECTION OF SLOPE. % MIN. ON HARDSCAPELOW POINTHEIGHTDIAMETERCONTINUOUSSIMILARPACDECOMPOSED GRANITEEQWSMINCOLHPLPDIACONTHTSIMO.CDGLPLTWTYPICALPLANTING AREACENTER LINEPROPERTY LINERADIUSEQUALWATER SURFACE LEVELALIGN ACCORDINGLYHEADER BOARDSPECIFICATIONS FOR THIS PROJECT ARE TO BE INCLUDED INELECTRONIC BOOK FORMAT. IF A COPY OF THE SPECIFICATIONS WASNOT RECEIVED, PLEASE CONTACT THE LANDSCAPE ARCHITECT OFRECORD FOR A COPY.DOWN RISERSMINIMUMCOLUMNHEIGHT POINTTOP OF WALL (AS MEASUREDFROM THE ADJACENT FINISH GRADE)ON CENTER811LANDSCAPEARCHITECTTWO WORKING DAYS BEFORE YOU DIGNORTHUNDERGROUNDSERVICE ALERTRGA PROJECT MANAGER:SPECIFICATIONS:CONSTRUCTION PLANCONSTRUCTION DETAILSIRRIGATION PLANIRRIGATION DETAILSPLANTING & LIGHTING PLANPLANTING DETAILSLIGHTING DETAILS260903/25/2021CITY COMMENT16/14/21EW L-1.00 THRU L-1.07L-2.00 THRU L-2.03L-3.00 THRU L-3.16L-4.00 THRU L-4.01L-5.00 THRU L-5.13L-6.00L-7.00ADAMS STTRACT 37359APN 600-340-048-1Shopoff34200 BOB HOPE DRIVE, RANCHO MIRAGE, CA 92270760.320.9811 MSACONSULTINGINC.COMWATER CONSERVATION STATEMENT:TOM MILLERtmiller@msaconsultinginc.com.comATTN: Torry Lozano2 Park Plaza, Suite 700Irvine, CA 92614E: tlozano@shopoff.com REAR YARD TYPICAL ENLARGEMENTS AREFOUND ON SHEETS L-X.09 THRU L-X.13WATER CALCULATIONSFOUND ON SHEETS L-3.14THRU L-3.16WASHINGTON STADAMS STDUNE PALMS RDJEFFERSON STAVENUE 48HWY 111SITECITY COMMENT : PLANTING RE UTILITIES29/28/21EBCITY COMMENT : VINES IN RETENTION BASIN310/19/21EBMAILBOX ADDITIONS411/17/21EBAPPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST12/21/2021 3:33:39 PMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FM2021-0004VEHICLE GATES - FIRE ACCESSKohl HetrickReason: I am approving this documentContact Info: 760-409-5109
PROD. 1-2APROD. 1-4APROD. 1-2APROD. 1-3APROD. 1-4APROD. 1-3A
PROD 2-1CPROD 2-1CPROD 2-2APROD 2-4APROD 2-3APROD 2-3APROD. 1-1XPROD. 1-1XPROD. 1-3APROD. 1-3APROD. 1-4APROD. 1-1XPROD. 1-1XPROD. 1-4APROD. 1-3APROD. 1-2APROD. 1-4APROD. 1-1APROD. 1-3APROD. 1-2APROD. 1-4APROD. 1-1APROD. 1-2APROD. 1-4APROD. 1-3APROD. 1-1APROD. 1-4APROD. 1-3APROD. 1-3APROD. 1-2APROD. 1-4APROD. 1-1APROD. 1-2APROD. 1-4APROD. 1-3APROD. 1-1APROD. 1-3APROD. 1-2APROD. 1-2APROD. 1-4APROD. 1-3APROD. 1-1APROD. 1-4APROD. 1-2APROD. 1-3APROD. 1-4APROD. 1-1XPROD. 1-1XPROD. 1-4APROD. 1-3APROD. 1-2APROD. 1-1XPROD. 1-1XPROD. 1-3APROD. 1-4APROD. 1-2APROD. 1-2APROD. 1-4APROD. 1-3APROD. 1-2A
PROD. 1-3A
PROD. 1-4A
PROD. 1-1A
PROD 2-4APROD 2-1CPROD 2-1CPROD 2-2APROD 2-3APROD 2-3APROD 2-4APROD 2-1CPROD 2-1CPROD 2-3APROD 2-3APROD 2-2APROD 2-2APROD 2-1CPROD 2-1CPROD 2-4APROD 2-3APROD 2-3APROD 2-1CPROD 2-1CPROD 2-2APROD 2-4APROD 2-3APROD 2-3APROD 2-1CPROD 2-1CPROD 2-2APROD 2-4APROD 2-3APROD 2-1CPROD 2-1CPROD 2-2APROD 2-4APROD 2-3APROD 2-3APROD 2-3APROD 2-3APROD 2-4APROD 2-2APROD 2-1CPROD 2-1CPROD 2-3APROD 2-3APROD 2-3APROD 2-4APROD 2-2APROD 2-1CPROD 2-1CPROD 2-3APROD 2-3APROD 2-4APROD 2-2APROD 2-1CPROD 2-1CPROD 2-3APROD 2-3APROD 2-4APROD. 1-2APROD. 1-2APROD. 1-2APROD. 1-1XPROD. 1-1X176124 PLAYSENSE
DESIGN 30
164075 DOUBLE
BOBBLE SPRING
RIDER
PRECISION
CAP
6x2x16
ACCENT BLOCK
SPLIT FACE BAND
8X8X16
PRECISION
CMU BLOCK
8X8X16
VARIESSEE CIVIL PLAN2"3'-6"1'MIN8X8X16
SCORE LINE BLOCK
2" SQ TUBE POST
@ 8' O.C.
1
2" SQ
TUBE PICKET
@4" O.C
1" SQ TUBE
RAILING 5'-9"8X8X16
SCORE LINE BLOCK
6X2X16
WALL CAP
1'3"2'4"4'-9"5"2" SQ TUBE POST
@ 8' O.C.
1
2" SQ
TUBE PICKET
@4" O.C
1" SQ TUBE
RAILING
1" SQ TUBE
RAILING
6'5'-6"DIMENSION KEYNOTES
NORTH CONSTRUCTION PLAN6/14/21
9/27/21
10/19/21
-
-
-
-
1
CITY COMMENTS
2
3
-
-
CITY COMMENTS:
PLANTING
FIRE DEPT COMMENTS:
PLANTING
-
-
-
-
-
-
EW
EB
EB
-
-
-PROJECT:SHEET TITLELANDSCAPE ARCHITECT:
PROJECT MANAGER:
DRAWN:
CHECKED:
PROJ. N0.
DATE:
SCALE:
REVISIONS:INIT.
SHEET N0:
TM
TM
2609
3/25/2021LA QUINTA, CA-
-
--
-
-
---
CONTINGENCY NOTE:
LANDSCAPE CONTRACTOR SHALL INCLUDE A CONTINGENCY
EQUAL TO 10% OF THEIR BID TO PROVIDE ADDITIONAL WORK OR
MATERIALS DURING CONSTRUCTION IF REQUESTED BY OWNER
OR LANDSCAPE ARCHITECT. ANY CONTINGENCY FUNDS NOT
USED SHALL BE REMITTED TO OWNER.
UTILITY EASEMENT NOTE:
ALL UTILITY EASEMENTS ARE TO REMAIN FREE OF ANY TREES, PLANTINGS OR STRUCTURES THAT WILL CAUSE A PROBLEM FOR THE
UTILITY COMPANY TO ACCESS OR TO USE THAT DEDICATED PORTION OF THE PROPERTY. THE UTILITY COMPANIES ARE WITHIN THE
LAW TO DEMOLISH OR DAMAGE ANYTHING THAT IS LOCATED WITHIN THE UTILITY EASEMENT THAT PREVENTS ACCESS AND USE OF
THE DEDICATED PORTION OF THE PROPERTY IF NECESSARY. UTILITY COMPANIES HAVE THE RIGHT TO ACCESS THEIR FACILITIES AT
ANY TIME FOR MAINTENANCE AND EMERGENCY PURPOSES. IF NECESSARY, THE UTILITY MAY REMOVE LANDSCAPING, STRUCTURES
OR ANYTHING ELSE BLOCKING ACCESS TO THEIR FACILITIES AT OWNER EXPENSE. UTILITIES ARE NOT RESPONSIBLE FOR REPLACING
ANY PLANTING WITHIN THEIR EASEMENT.
LANDSCAPE ARCHITECTS
A DESIGN STUDIO OF MSA CONSULTING, INC .
> LANDSCAPE ARCHITECTURE > PLANNING
> CIVIL ENGINEERING > LAND SURVEYING
34200 BOB HOPE DRIVE, RANCHO MIRAGE, CA 92270
760.320.9811 MSACONSULTINGINC.COM
MSA CONSULTING, INC.
-THE CENTRE AT LA QUINTAGRAPHIC SCALE
SCALE: 1" = 50'-0"
GRAPHIC SCALE
100'025'50'150'
L-1.00
-
1"=50'-0"
W1
PA
1.02A
1.02C
1.02D
1.02B
1.02F
1.02
1.01B
W2
F2
F2
F3
P1P1
P1
P1
P2
P2
P3
P3
P2
P4P5
PA
PA
PA
PAPA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
P1
P2
1
2
2
2
5
1
1.01A
1.02E
1.04 1.05
P1 LA QUINTA DRIVEADAMS STREETPERIMETER WALL 6' HIGH
8X8X16 PRECISION BLOCK W/
2X8X16 WALL CAP BY ORCO.
STACK PATTERN. SEE CIVIL PLAN
FOR RETAINING CONDITION
OCCURS
6' HIGH FENCE.
FENCE POST @ 8' O.C.
3'-6" HIGH FENCE ON
RETAINING WALL
8X8X16 503 SCORE ONE SIDE
PRECISION BLOCK BY ORCO.
STACK BOND PATTERN.
GARDEN WALL 5'-9" HIGH
8X8X16 503 SCORE BOTH SIDE
PRECISION BLOCK BY ORCO.
STACK PATTERN. SEE CIVIL PLAN
FOR RETAINING CONDITION
OCCURS
1/2" = 1'-0"1/4" = 1'-0"
1/4" = 1'-0"
FINISH: PRECISION
COLOR :
SOURDOUGH(ORCO)
MORTAR: MATCH
FINISH: SPLIT FACE
COLOR :
SOURDOUGH(ORCO)
MORTAR: MATCH
FINISH: PRECISION
COLOR :
SOURDOUGH(ORCO)
MORTAR: MATCH
1/4" = 1'-0"
FINISH: PRECISION
COLOR :
SOURDOUGH(ORCO)
MORTAR: MATCH
NOTES:
1.FOOTING SIZE AND REINFORCING FOR BIDDING
PURPOSES ONLY. IF STRUCTURAL DESIGN IS
REQUIRED, THAT SHALL BE PROVIDED BY A LICENSED
STRUCTURAL ENGINEER
2.CMU MANUFACTURE: ORCO BLOCK (760-347-3245)
5
24
W1. PERIMETER WALL W2. GARDEN WALL
F2. POOL FENCEF1. FENCE ON RETAINING WALL
COLOR:
DUNN EDWARD
DET681
MODERN CLASS
SEMI-GLOSS ENAMEL
19
23
(1) 16 CMPRT
CBU
23
(1) LARGE
PARCEL LOCKER
23(1) 8 CMPRT
CBU
(1) 13 CMPRT
CBU
23
(1) 12 CMPRT
CBU
(1) 8 CMPRT CBU
(1) 13 CMPRT CBU
2323
(1) 8 CMPRT CBU
(2) 12 CMPRT CBU
23(2) 13 CMPRT
CBU
(1) 16 CMPRT
CBU
8'-9"2'-6"3'-2"2'-6"3'-3"2'-6"2'-6"
22'19'-3"22'6'5'4'2'R40'PROD 2-4A5'37'5'3'-9"6'-9"
16'-6"6'-9"4'-6"5'-3"1
3'-3"ALIGN W/ STRUCTURE/OPENING
ALIGN/CENTER ON STRUCTURE, WALL OR OPENING
ALIGN CONTROL JOINTS I CONC-SLAB W/ RADIUS POINT OF CURB
1
2
DIMENSION KEYNOTES
CONSTRUCTION PLAN6/14/21
9/27/21
10/19/21
-
-
-
-
1
CITY COMMENTS
2
3
-
-
CITY COMMENTS:
PLANTING
FIRE DEPT COMMENTS:
PLANTING
-
-
-
-
-
-
EW
EB
EB
-
-
-PROJECT:SHEET TITLELANDSCAPE ARCHITECT:
PROJECT MANAGER:
DRAWN:
CHECKED:
PROJ. N0.
DATE:
SCALE:
REVISIONS:INIT.
SHEET N0:
TM
TM
2609
3/25/2021LA QUINTA, CA-
-
--
-
-
---
CONTINGENCY NOTE:
LANDSCAPE CONTRACTOR SHALL INCLUDE A CONTINGENCY
EQUAL TO 10% OF THEIR BID TO PROVIDE ADDITIONAL WORK OR
MATERIALS DURING CONSTRUCTION IF REQUESTED BY OWNER
OR LANDSCAPE ARCHITECT. ANY CONTINGENCY FUNDS NOT
USED SHALL BE REMITTED TO OWNER.
UTILITY EASEMENT NOTE:
ALL UTILITY EASEMENTS ARE TO REMAIN FREE OF ANY TREES, PLANTINGS OR STRUCTURES THAT WILL CAUSE A PROBLEM FOR THE
UTILITY COMPANY TO ACCESS OR TO USE THAT DEDICATED PORTION OF THE PROPERTY. THE UTILITY COMPANIES ARE WITHIN THE
LAW TO DEMOLISH OR DAMAGE ANYTHING THAT IS LOCATED WITHIN THE UTILITY EASEMENT THAT PREVENTS ACCESS AND USE OF
THE DEDICATED PORTION OF THE PROPERTY IF NECESSARY. UTILITY COMPANIES HAVE THE RIGHT TO ACCESS THEIR FACILITIES AT
ANY TIME FOR MAINTENANCE AND EMERGENCY PURPOSES. IF NECESSARY, THE UTILITY MAY REMOVE LANDSCAPING, STRUCTURES
OR ANYTHING ELSE BLOCKING ACCESS TO THEIR FACILITIES AT OWNER EXPENSE. UTILITIES ARE NOT RESPONSIBLE FOR REPLACING
ANY PLANTING WITHIN THEIR EASEMENT.
CVWD NOTE:
NO PERMANENT STRUCTURES OR TREES WITHIN CVWD OR USBR
EASEMENTS. CVWD WILL NOT BE RESPONSIBLE FOR CHANGE OR
REPLACEMENT OF ANY SURFACE IMPROVEMENTS,INCLUDING
BUT NOT LIMITED TO DECORATIVE CONCRETE, LANDSCAPING,
CURB, GUTTER, SIDEWALKS,PLANTERS, GATES AND RELATED
IMPROVEMENTS INSTALLED WITHIN CVWD AND /OR USBR
EASEMENT
LANDSCAPE ARCHITECTS
A DESIGN STUDIO OF MSA CONSULTING, INC .
> LANDSCAPE ARCHITECTURE > PLANNING
> CIVIL ENGINEERING > LAND SURVEYING
34200 BOB HOPE DRIVE, RANCHO MIRAGE, CA 92270
760.320.9811 MSACONSULTINGINC.COM
MSA CONSULTING, INC.
-THE CENTRE AT LA QUINTAL-1.01
-
1"=20'-0"
L-1.01
A
L-1.01
B L-1.02
A
L-1.02
B
L-1.02
C
L-1.02
D
L-1.02
E
L-1.02
F
L-1.03
L-1.04 L-1.05
LA QUINTA DRIVEADAMS STREETNORTH
20'0
GRAPHIC SCALE
5'10'
SCALE: 1" = 10'-0"
30'
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
P3
P3
P1
3
W1
W2
W1
P2
1
2
1
P2
P1
P1
P1
P1
2
2
1
W1
W2
W1
AREA A AREA B LA QUINTA DRIVEPA
PA
GATE OPERATION EQUIPMENT
LOCATION, SPECIFICATIONS, &
ELECTRICAL CONNECTION TO BE
COORDINATED WITH OWNER AND
PROVIDED BY GATE CONTRACTOR.
GATE OPERATION EQUIPMENT
LOCATION, SPECIFICATIONS, &
ELECTRICAL CONNECTION TO BE
COORDINATED WITH OWNER AND
PROVIDED BY GATE CONTRACTOR.
11
2
3
4
5
6
2" SQ. TUBE STEEL FRAME
HINGE DESIGN BY GATE FABRICATOR
9
7
ADJACENT 8X8X16 BLOCK WALL
PERFORATED METAL
3" SQ. STEEL POST. ATTACH TO BLOCK
WALL W/ 1
2" DIAM. WELDED STUDS @ 16
O.C. WELD END CAP TO TOP OF
CHANNEL
NOTE
1.WELD ALL CONNECTIONS & GRIND SMOOTH. FINISH ALL METAL SURFACES W/1
COAT OF ZINC-CHROMATE PRIMER & 2 COATS OF EXTERIOR GRADE / SEMI-GLOSS
ENAMEL. COLOR TO BE DUNN EDWARDS 681 CONTRACTOR TO SUBMIT SHOP
DRAWINGS TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO FABRICATION.
2.ALL STEEL TO BE GALVANIZED
3.PILASTER FOUNDATION BY OTHERS
PEDESTRIAN GATE
1/2" = 1'-0"-
8
PRECISION COLUMN BLOCK
16X8X16
FINISH: SPLIT FACE
COLOR: SOURDOUGH
PRECISION CAP 4X2X16
FINISH/COLOR MATCH COLUMN
9 8
PLAN VIEW a
SECTION a - a 6'8"6"
7
FG
8
14 GAGE 2" WIDE STEEL LOCK
BOX, 2 3/4" BACKSET FLAT
SURFACE W/ ASTRAGAL
#K-BXSGL234-2W BY KEEDEX.
EXTERIOR GRADE LOCK SET TO
BE MOUNTED AT 42" ABOVE
ADJACENT FINISH GRADE.
CONTRACTOR RESPONSIBLE TO
PROVIDE SPECIFICATION TO
OWNERSHIP PRIOR TO
INSTALLATION.
6
5
134 2
29
3"5'-9"5'-0"
SITE VERIFIED
2'-9"
ELEVATION
10 #4 HORIZONTAL
10
11
11 #4 32" O.C. VERTICAL
12 CONCRETE FOOTING BY OTHERS
12
RECESSED 3200 SERIES KNOX BOX SHALL BE MOUTNED TO THE RIGHT
OF THE GATE SO THE TOP IS 6FT IN HEIGHT FACING THE STREET. SEE
GATE/FIRE DEPARTMENT NOTES BELOW. AN ELECTRONIC KNOX BOX
KEY SWITCH IS REQUIRED ON THE MONUMENT. VISIT
WWW.KNOXBOX.COM TO ORDER THE KNOX BOX KEY SWITCH.
RECESSED 3200 SERIES KNOX BOX SHALL BE MOUTNED TO THE RIGHT
OF THE GATE SO THE TOP IS 6FT IN HEIGHT FACING THE STREET. SEE
GATE/FIRE DEPARTMENT NOTES BELOW. AN ELECTRONIC KNOX BOX
KEY SWITCH IS REQUIRED ON THE MONUMENT. VISIT
WWW.KNOXBOX.COM TO ORDER THE KNOX BOX KEY SWITCH.
1 245
11
2
3
4
5
6
67
7
10'-10" SITE VERIFIED 1'-4"5'-6"7"HINGE DESIGN BY GATE FABRICATOR
9
10
10
9
VEHICULAR GATE
1/2" = 1'-0"-
PERFORATED METAL FOR GATE INFILL PANEL EQUAL TO
QUALITY 3/8" SQUARE ON 1/2" CENTER PERFORATED
METAL PLAN STEEL WITH 56% OPENING BY MCNICHOLS.
-
b
3" SQ. TUBE STEEL FRAME.
1"X2" TUBE STEEL FRAME
1"x2" RECTANGULAR PICKETS @4" O.C.
W/1" FACING OUT
A. MAIN ENTRY AUTOMATIC - HALF
B. SECONDARY ENTRY MANUAL OPERATION - HALF
8 1'-2"3
6'-0"1 24567
18'-10" SITE VERIFIED 1'-1"5'-6"7"10
9
1'-2"3
6'-0"4 1/2" x 4 1/2" SINGLE ACTION SPRING HINGES SELF
CLOSING (MIN. OF 3) PER GATE EQUAL TO PR(S) CAL
ROYAL STAINLESS STEEL
4 - 1/2" x 4" STRONG-TIE TITEN HD SCREW STEEL ANCHOR
BY SIMPSON
COLUMN. SEE DETAIL L, SECTION a-a
ADJACENT BLOCK WALL. SEE DETAIL W1 SHEET L-1.00
6X8 STEEL TUBE POST W/ STUD BOLTS SET W/ CMU
11 FOOTING BY OTHERS
11
11
1213567
10'-0" SITE VERIFIED 5'-6"3"10
9
C. MAINTENANCE ENTRY MANUAL OPERATION-HALF6'-0"12 2" SQ TUBE STEEL FRAME
13 3/4" SQ TUBE PICKETS @4" O.C.
12135616
7'-6" SITE VERIFIED 5'-6"3"D. MAINTENANCE ENTRY MANUAL OPERATION - HALFSEE CIVIL PLANSECTION b-b
14 1" SQ TUBE PICKETS @4" O.C.
15
15
1515
16 ADJACENT RETAINING WALL & FENCE COMBINATION. SEE
DETAIL F1, SHEET L-1.00
11
11
GENERAL GATE NOTES:
1. GATE CONTRACTOR TO SUPPLY KNOX KEY BOX LOCATION AND SPECIFICATIONS PER FIRE DEPARTMENT REQUIREMENTS.
2. WELD ALL CONNECTIONS & GRIND SMOOTH. ALL STEEL TO BE HOT DIPPED GALVANIZED. FINISH ALL METAL SURFACES W/1 COAT OF
ZINC-CHROMATE PRIMER & 2 COATS OF SEMI-GLOSS EXTERIOR GRADE ENAMEL. COLOR TO BE SELECTED BY OWNER.
3. CONTRACTOR TO SUBMIT SHOP DRAWINGS TO LANDSCAPE ARCHITECT FOR APPROVAL OF GATES PRIOR TO FABRICATION.
4. ALL STRUCTURAL DETAILS TO BE PROVIDED BY CALIFORNIA LICENSED STRUCTURAL ENGINEER.
5. GATE WIDTHS TO BE DETERMINED AFTER WALL CONSTRUCTION. CONTRACTOR TO FIELD VERIFY PRIOR TO CONSTRUCTION OF GATES.
GATE/FIRE DEPARTMENT NOTES:
1. THE RESIDENTIAL ENTRY GATES WILL BE INSTALLED IN ACCORDANCE WITH UL 325, ASTM F2200 STANDARDS, 2019 CALIFORNIA FIRE CODE. CFC
503.6
2. KNOX BOXES SHALL BE MOUNTED TO THE RIGHT OF THE GATE, SO THE TOP IS 6 FEET IN HEIGHT FACING THE STREET. VISIT WWW.KNOXBOX.COM
TO ORDER THE KNOX BOX. PROVIDE A SET OF KEYS WITH IDENTIFICATION TAGS FOR THE VEHICULAR EMERGENCY ACCESS GATES WHICH WILL BE
STORED INSIDE THE KNOX BOXES FOR FIRE DEPARTMENT ACCESS. CFC 506.1.
3. THE GATE OR ARM, WHEN FULLY OPENED SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 24 FEET FOR SINGLE ROADWAY GATES. SUB-DIVISIONS
MAY HAVE A DIVIDED ENTRANCE AND EXIT GATES. THE ENTRANCE SIDE SHALL HAVE A CLEARANCE OF 16 FEET CLEAR WIDTH, THE EXIT SIDE 16
FEET CLEAR WIDTH. IF A BOULEVARD IS PRESENT, THE DIMENSIONS INCREASE TO 24 FEET ON BOTH SIDES. CITY OF INDIO ORDINANCE, CHAPTER 5
SECTION 503.2.1
4. NOTHING IN LA QUINTA FIRE DEPARTMENT’S REVIEW SHALL BE CONSTRUED AS ENCOMPASSING STRUCTURAL INTEGRITY. REVIEW OF THIS PLAN
DOES NOT AUTHORIZE OR APPROVE ANY OMISSION OR DEVIATION FROM ALL APPLICABLE REGULATIONS. FINAL FIELD INSPECTION SHALL VERIFY
ALL REQUIREMENTS. ALL QUESTIONS REGARDING THE MEANING OF THE CODE REQUIREMENTS SHOULD BE REFERRED TO THE FIRE PREVENTION
BUREAU AT 760-564-2122.
5. A FINAL INSPECTION IS REQUIRED BY THE FIRE DEPARTMENT WITH GATE CONTRACTOR PRESENT. INSPECTIONS CAN BE SCHEDULED BY
CALLING 760-347-0756 A MINIMUM OF 48 HOURS IN ADVANCE OF THE INSPECTION DATE.
HEAVY DUTY EXTERIOR GRADE LOCK TO BE
PROVIDED BY GATE CONTRACTOR. SEE FIRE
DEPARTMENT NOTES FOR FURTHER LOCK
INFORMATION.
GATE/FIRE DEPT NOTES CONTINUED:
6. AN APPROVED OPTICAL TRAFFIC PREEMPTION DEVICE (TPD) MUST BE INSTALLED ON ALL
AUTOMATICALLY OPERATED GATES. THESE DEVICES MUST BE OF DIGITAL DESIGN.
ANALOG UNITS ARE NOT ACCEPTABLE. BI-DIRECTIONAL OR MULTIPLE DEVICES MAY BE
NEEEDED IN ORDER TO ACHIEVE THE DESIRED PERFORMANCE WHEN ENTRY
CONFIGURATIONS ARE OF A MORE COMPLEX NATURE.
7. ACTIVATION OF THE TPD SHALL RESULT IN THE GATE REMAINING IN THE OPEN POSITION
FOR A MINIMUM OF 30 SECONDS TO ALLOW FIRE DEPARTMENT UNITS TO GAIN
UNRESTRICTED ENTRY AFTER WHICH TIME THE GATE SHALL AUTOMATICALLY RESET BACK TO
NORMAL OPERATION.
6
591'-4"1 4
CONCRETE FOOTING BY OTHERS
COMPACTED SUBGRADE
#4 HORIZONTAL
#4 32" O.C. VERTICAL 2"7
8
5
6
FG
SIGN MONUMENT
1/2" = 1'-0"-
2
6
7
8
11
2
3
4
5
PRECISION CMU CAP 6x2x16
4
2'-0"6'-0"8"8"8'-0"
LA QUINTA
2
3
4
NOTE:
1.SIGN DETAILS BY SIGN COMPANY , PER SEPARATED PERMIT
2.REFER TO DETAIL W1, SHEET L-2.00 FOR CONSTRUCTION DETAIL OF WALL.
3.FONT STYLE, SIZE, MATERIALS AND MOUNTING DETAILS PER SIGN CONTRACTOR.
6"
9
9
1
EQEQ
PRECISION CMU CAP 8X8X16
ACCENT BLOCK SPLIT FACE BAND
8X8X16
2
3
9
SECTION a - a
ELEVATION
LETTER "LA QUINTA"
6" DEEP FREE STANDING LETTERS
"CENTRE"CONSTRUCTION DETAILSL-2.01
PER DETAIL
6/14/21
9/27/21
10/19/21
-
-
-
-
1
CITY COMMENTS
2
3
-
-
CITY COMMENTS:
PLANTING
FIRE DEPT COMMENTS:
PLANTING
-
-
-
-
-
-
EW
EB
EB
-
-
-PROJECT:SHEET TITLELANDSCAPE ARCHITECT:
PROJECT MANAGER:
DRAWN:
CHECKED:
PROJ. N0.
DATE:
SCALE:
REVISIONS:INIT.
SHEET N0:
TM
TM
2609
3/25/2021LA QUINTA, CA-
-
--
-
-
---
LANDSCAPE ARCHITECTS
A DESIGN STUDIO OF MSA CONSULTING, INC .
> LANDSCAPE ARCHITECTURE > PLANNING
> CIVIL ENGINEERING > LAND SURVEYING
34200 BOB HOPE DRIVE, RANCHO MIRAGE, CA 92270
760.320.9811 MSACONSULTINGINC.COM
MSA CONSULTING, INC.
-THE CENTRE AT LA QUINTAEW
K L
--
PERFORATED METAL
DESIGNER PERFORATED, SQUARE,
LATTICE 0853, ALUMINUM, ALLOY
3003-H14, .1250" THICK (8 GAUGE), 1/2"
SQUARE ON 11/16" STRAIGHT CENTERS,
53% OPEN AREA
ENAMEL
DUNN EDWARD DET681
MODERN CLASS
SEMI-GLOSS ENAMEL
NELEVATION
NTSM SECONDARY ENTRY
MAIN ENTRY
1
Hetrick, Kohl@CALFIRE
From:Hetrick, Kohl@CALFIRE
Sent:Tuesday, April 18, 2023 1:00 PM
To:David Kinnett
Cc:Jose Delgado; Rojas, Leilani@CALFIRE
Subject:Solterra Gates - Call Box Location
Attachments:FSINSP2022-0010 - 9-20-2022 - INSPECTION REPORT - FLAT.pdf; FM2021-0004 - COA AND JOB CARD.pdf; FM2021-0004 - APPROVED
GATE PLANS.pdf
Dave,
AƩached is the historical Fire InspecƟon report associated with Fire Access and Water verificaƟon.
Also the CondiƟons of Approval LeƩer & Job Card, as well as the approved gate plans for referenced permit FM2021-0004. The permit was approved on 12/21/2021 and
fees are sƟll due for payment.
In regards to the CallBox locaƟon for the main entry:
Thank you,
KOHL HETRICK
Fire Safety Specialist / Office of the Fire Marshal
City of La Quinta & County Strategic Planning
CAL FIRE/Riverside County Fire Department
Desk: 760-777-7074 | Mobile: 760-409-5109
Inspection Hotline: 760-777-7131
78495 Calle Tampico, La Quinta, CA 92253
kohl.hetrick@fire.ca.gov | www.rvcfire.org
Sch: Mon-Thurs
Leadership, Competence, Integrity, Safety, Customer Service
The Office of the County Fire Marshal is committed to facilitating fire and life safety solutions by empowering its employees to serve our community through innovation and
partnership.
RESPONSE TO COMMENTS
DATE: 29 November 2021
PROJECT: Centre at La Quinta:
PROJECT NO: 2609
SUBJECT: Main & Emergency Entry Gates Fire Submittal: Comments Re Eqpmt
Description of review/agency comments
1. Redlines on cover sheet to indicate need to remove water conservation statement
and CVWD approval stamp/record.
a. Response: Water Conservation statement and CVWD Landscape Approval
indication are removed from this set.
2. Main Entry, L-1.01: Identify location of KNOX key switch and provision of OPTICOM
IR Receiver for rapid Fire Access through the gate. Preference of KNOX key switch
on Pedestal.
a. Response: Official design and technical information to be supplied by Gate
Contractor. Knox box proposed location & notes added on Detail M
(Elevations), Sheet L-2.01
b. Additional Gate/Fire Dept Notes (6 & 7) regarding TPD added on Detail K, L-
2.01
3. Main Entry, L-1.01: Identify the location, make, model and UL325 compliant electric
gate operators.
a. Response: Approximate size and location added to plan. Official design and
technical information to be supplied by Gate Contractor.
4. Emergency Entry, L-1.01: Identify location of KNOX key switch and provision of
OPTICOM IR Receiver for rapid Fire Access through the gate.
a. Response: Official design and technical information to be supplied by Gate
Contractor. Knox box proposed location & notes added on Detail M
(Elevations), Sheet L-2.01
b. Additional Gate/Fire Dept Notes (6 & 7) regarding TPD added on Detail K, L-
2.01
5. Emergency Entry, L-1.01: Identify the location, make, model and UL325 compliant
electric gate operators.
a. Response: Approximate size and location added to plan. Official design and
technical information to be supplied by Gate Contractor.
OFFICE OF THE FIRE MARSHAL – LA QUINTA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
December 21, 2021
SLF Adams Street, La Quinta LLC
2 Park Plaza #200
Irvine, CA 92614
Re: Vehicle Gate – Fire Access - Plan Review – THE CENTRE – LA QUINTA
FM2021-0004 / ADAMS STREET X SUNFLOWER LANE
The plans you submitted for the above referenced project have been reviewed by Riverside County Fire
Department - Office of the Fire Marshal personnel and are approved with the following conditions.
The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff:
(a) Gate Clear Opening Width
(b) UL325 Listed Electric Gate Operator confirmed
(c) KNOX Access
(d) Infrared Signal Access – Will need to coordinate Fire Apparatus to perform site visit and operate
emergency lights to create the access activation.
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
RIVERSIDE COUNTY FIRE PROTECTION PLANNING
RECORD OF INSPECTIONS / PERMIT CARD
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS: THE CENTRE TM 37359 PERMIT#: FM2021-0004 DATE
ISSUED: 12/21/2021
DESCRIPTION: VEHICLE GATES – FIRE ACCESS APPLICANT: SLF ADAMS STREET, LA QUINTA LLC
HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS
Thrust block pre-pour Door fan test
UG rough piping Abort test
UG hydro Mechanical shutdown
Flush Detector test
Final E F Deluge/pre-action
SPRINKLER U.G. Final E F
Thrust block pre-pour UST/AST TANK
UG rough piping Installation
UG hydro Removal
Flush Emergency shut off
Final E F Primary piping
FIRE SPRINKLER Secondary piping
Weld inspection Dispensers & shear valves
Overhead rough piping Final E F
Overhead hydro MISC. INSPECTIONS
UG flush / OK to connect Spray booths
Main drain/inspectors’ test Hood/duct extinguishing
High pile storage High pile rack storage
In-rack sprinklers H.P. vents/access/corridors
Hose racks Tract access/hydrant verification
Final E F Access & Address verification
HOOD EXTINGUISHING OTHER CONST. PERMIT
Detection system Vehicle Gate – Fire Access
Function test UL325 Listed Elec. Gate Operators
Gas/electrical shut-off Infrared Signal Access
Nozzle model/placement
Fire alarm connection
Final E F
SPRAY BOOTHS FIRE CODE PERMIT(S)
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final E F
FIRE ALARM KNOX SYSTEM
Rough-wire inspection Building Knox box
Function test Gate access Knox box/padlock
Duct detectors/velocity BUILDING INSPECTIONS
24 hr. battery test T/I final
Sprinkler monitoring Shell final
Final E F Final for occupancy
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE**
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspections. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.