Loading...
FNCUW2021-0002ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES EMAIL EXCHANGE: RE: FNCUW2021-0002 Hi Bill, So long as there is no functional difference in making the connections and the fittings, then yes C-900 may be used. It would be necessary to provide “As-Builts” prior to final inspection. Thank you, KOHL HETRICK Fire Safety Specialist / Office of the Fire Marshal Cal Fire/Riverside County Fire Department City of La Quinta Description: EXTENSION OF PVT FIRE MAIN FOR NEW SPRINKLER SYSTEM Type: FIRE NEW COMMERCIAL UNDERGROUND WATER (WEB) Subtype: Status: FINALED Applied: 9/13/2021 EPRS Parcel No: 600390011 Site Address: 79120 CORPORATE CENTER DR LA QUINTA,CA 92253 Approved: 9/27/2021 KHET Subdivision: PM 29351 Block: Lot: 1 Issued: 10/4/2021 JLIM Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 12/28/2021 KHET Valuation: $50,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: NEW UNDERGROUND FIRE MAIN SERVICE FOR SERVICE FOR NEW SELF-STORAGE BUILDING PER BCOM2021-0007. Printed: Friday, February 24, 2023 11:15:09 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FNCUW2021-0002 E-MAIL KOHL HETRICK 10/18/2021 10/18/2021 Desk: 760-777-7074 | Mobile: 760-409-5109 Inspection Hotline: 760-777-7131 78495 Calle Tampico, La Quinta, CA 92253 kohl.hetrick@fire.ca.gov | www.rvcfire.org Sch: Mon-Thurs Leadership, Competence, Integrity, Safety, Customer Service The Office of the County Fire Marshal is committed to facilitating fire and life safety solutions by empowering its employees to serve our community through innovation and partnership. From: William Strand <bstrand@strandengineeringinc.com> Sent: Monday, October 18, 2021 10:58 AM To: Hetrick, Kohl@CALFIRE <Kohl.Hetrick@fire.ca.gov> Subject: RE: La Quinta Extra Space Storage Building Warning: this message is from an external user and should be treated with caution. Kohl, During construction the contractor has exposed the existing 8” fire line and it is C900 not DIP as I had thought. The contractor want’s to know if the can use C900 instead of the DIP called out on the Fire Main Plans? Thank you for your assistance. William Strand, MS, PE, QSD Strand Engineering, Inc. www.strandengineeringinc.com 1001 Avenida Pico, Ste. C-121 San Clemente, CA 92673 O. (949) 431-0610 C. (209) 605-5753 CONDITIONS Printed: Friday, February 24, 2023 11:15:09 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FNCUW2021-0002 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT JUDY LEE 555 WEST 5TH STREET, 35TH FLOOR LOS ANGELES CA 90013 (949)829-3286 JUDY@LATIERRACONS ULTING.COM BILL TO JUDY LEE 555 WEST 5TH STREET, 35TH FLOOR LOS ANGELES CA 90013 (949)829-3286 JUDY@LATIERRACONS ULTING.COM CONTRACTOR INLAND VALLEY PIPELINE INC P O BOX 1084 TEMECULA CA 92593 (949)829-3286 OFFICE@INLANDVALLE YPIPELINE.COM OWNER EXTRA SPACE PROP 126 PO BOX 800729 DALLAS TX 75380 (949)829-3286 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE NEW COMMERCIAL - UNDERGROUND WATER 101-0000-42421 0 $483.00 $483.00 10/4/21 WEB9476 632803353 43 CREDIT JUDY LEE EPRS FIRE NEW COMMERCIAL - UNDERGROUND WATER PC 101-0000-42420 0 $403.00 $403.00 10/4/21 WEB9476 632803353 43 CREDIT JUDY LEE EPRS Total Paid for FIRE FEES: $886.00 $886.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 10/4/21 WEB9476 632803353 43 CREDIT JUDY LEE EPRS Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 10/4/21 WEB9476 632803353 43 CREDIT JUDY LEE EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$901.00 $901.00 Printed: Friday, February 24, 2023 11:15:09 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FNCUW2021-0002 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/13/2021 Etrakit Public Registration 1ST SUBMITTAL UNDERGROUND FIRE MAIN PLANS 1ST SUBMITTAL - UNDERGROUND FIRE MAIN PLANS.pdf 1 DOC 9/13/2021 Etrakit Public Registration 1ST SUBMITTAL UNDERGROUND FIRE MAIN CUT SHEETS 1ST SUBMITTAL - ALL CUT SHEETS.pdf 1 DOC 9/27/2021 KOHL HETRICK FNCUW2021-0002 - APPROVED PLANS.pdf FNCUW2021-0002 - APPROVED PLANS.pdf 1 DOC 9/27/2021 KOHL HETRICK 1ST SUBMITTAL - ALL CUT SHEETS.pdf 1ST SUBMITTAL - ALL CUT SHEETS_1.pdf 1 DOC 12/7/2021 KOHL HETRICK FNCUW2021-0002 - COA AND JOB CARD.pdf FNCUW2021-0002 - COA AND JOB CARD.pdf 1 BOND INFORMATION DATE DATE THRUST BLOCK PRE-POUR KHET 12/13/2021 12/13/2021 APPROVED Next inspection is hydro at line pressure only. UG HYDRO KHET 12/14/2021 12/14/2021 APPROVED POST POUR & HYDRO REMOTE VIDEO INSPECTION - OBSERVED SYSTEM STATIC PRESSURE. FLUSH KHET 12/28/2021 12/28/2021 APPROVED FIRE FINAL**KHET 12/28/2021 12/28/2021 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 9/13/2021 9/14/2021 9/13/2021 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 9/13/2021 9/27/2021 9/27/2021 APPROVED SEE ATTACHMENTS PARENT PROJECTS Printed: Friday, February 24, 2023 11:15:09 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FNCUW2021-0002 8" FIRE95 LF8" SDS=.0035168 LF8" SDS=.003524" SDS=0.095 LF8" SDS=.0035144 LF8" SDS=.003512" SDS=.002WWWWC.V.W.D. STORM WATER CHANNELQ10 = 1.7 CFS1001 Avenida Pico, Ste. C-121, San Clemente, CA 92673 (949) 431-0610C:\Users\stran\OneDrive\Projects\1012 Extra Space 1561 La Quinta\Engineering\ConDocs\Sheet-Files\1012-TS-Fire Main.dwg, TITLE, Sep 03, 2021 8:19am, stranKnow what'sRTITLE SHEETFIRE MAIN PLANEXTRA SPACE 1561 LA QUINTA79120 CORPORATE CENTER DRIVECITY OF LA QUINTA, CAPM 29351 PARCEL 1APN: 600-390-011SHEET INDEX1 TITLE SHEET3 DEMOLITION PLAN5 UTILITY/HORIZONTAL CONTROL PLAN7 DETAILSVICINITY MAPNOT TO SCALECORPORATE CENTER DRADAMS STREETHIGHWAY 111DUNE PALMS ROADLA QUINTA DRAUTO CENTER DRCORPORATE CENTER DRSITEC.V.W.D STORM WATER CHANNELNORTHWATER CONSTRUCTION NOTES1CONNECT TO EX. FIRE LINE WITH MECH. JOINT, WRAP IN POLYETHYLENE2STORM DRAIN CONSTRUCTION NOTESCONSTRUCTION NOTES1INSTALL AC PAVEMENT23SAWCUTESTIMATED QUANTITIES1,235 LFFEMA FLOODZONEZONE: X0.2% ANNUAL CHANCE FLOOD HAZARDLEGAL DESCRIPTIONPARCEL 1 AS SHOWN ON PM 29351IN THE CITY OF LA QUINTA, COUNTYOF RIVERSIDE, STATE OF CALIFORNIAAREA: 3.8 ACUTILITY CONTACT INFORMATIONWATER: COACHELLA VALLEY WATER DISTRICT (760) 398-2651ELECTRIC: IMPERIAL IRRIGATION DISTRICT (800) 303-7756TELEPHONE: VERIZON (888) 553-1555BENCHMARKCALIFORNIA DEPT. OF TRANSPORTATION, 3" BRASS DISK FOUND AT THEINTERSECTION OF HWY 111 AND LA QUINTA CENTER DRIVENAVD 88 ELEV = 81.62SOURCE OF TOPOGRAPHYTOPOGRAPHIC SURVEY CONDUCTED 7/1/2020 BYGRENIER & SONS, INC.REFERENCE DRAWINGSLA QUINTA SELF STORAGE II PRECISE GRADING PLAN SDP 2000-673STORM DRAIN SD571101-SD571105EARTHWORKCUT = 841 CYFILL= 841NET EXPORT= 0INDEX MAPSCALE 1"=40'NORTH5,088 SF215 LF2 EA86 LF533 LF4 EA5 EA1 LS174 LFLEGEND2.5" AC4" CLASS II A.B. COMPACTED TOMIN. 95% RELATIVE DENSITY12" COMPACTED SUBGRADE TOMIN. 90% RELATIVE DENSITYPAVEMENT SECTION*NOTE: ALL CONCRETE CONSTRUCTION SHALL BE IN CONFORMANCEWITH CITY STD. DETAIL 200INSTALL 3' CONC. VALLEY GUTTER PER DETAIL B, SHEET 71INSTALL PVC STORM DRAIN LINE (SCH40) PER MANUFACTURERRECOMMENDATIONS2INSTALL DOWNSPOUT CONNECTION PER DETAIL E, SHEET 73INSTALL CLEANOUT PER DETAIL G, SHEET 745INSTALL INFILTRATION TRENCH PER DETAIL D, SHEET 7INSTALL 24" NYLOPLAST DRAIN INLET W/ REM TR14CR(32) FILTER WITH MEDIAPER DETAIL A, SHEET 76INSTALL DRYWELL PER DETAIL F, SHEET 75 EAINSTALL 8" POLYETHYLENE WRAPPED DIP CL150 FIRE LINE PER DETAIL H, SHEET 73EX. FIRE HYDRANT, VALVE, GUARD POSTS - PROTECT IN PLACE45CONSTRUCT 4" POLYETHYLENE WRAPPED DIP FIRE RISER SERVICE W/BOLLARDS, 8"X4" TEE & VALVE PER DETAIL L, SHEET 73 EA1 EA1 EAREMOVE EX. FIRE HYDRANT, LATERAL TO VALVE, CLOSE VALVE, REMOVERISER, REMOVE VALVE BOX, BACKFILL TRENCH PER DETAIL H, SHEET 76INSTALL TYPE C BLUE REFLT. MARKER, CEMENT W/ HOTMELT BITUMEN ADHESIVE3EAINLAND VALLEY PIPELINE, INCCONT. LISC. # A-88725333020 HOWARD ROADMENIFEE, CA 92584(951) 541-6814OFFICE@INLANDVALLEYPIPELINE.COMCONTACT: JAIME BAHRFIRE LINE CONTRACTORLa Quinta Office of the Fire MarshalFire Safety Specialist Kohl Hetrick - 760-777-7074 / kohl.hetrick@fire.ca.govKohl HetrickReason: I am approving this documentContact Info: 760-409-5109Date: 2021.09.27 16:42:23-07'00' 696868 696868W W W W W WWWW WWWW8" FIRE PROPERTY LINEPROPERTY LINE PROPERTY LINE 1EX. FH, BOLLARDS,VALVE1EX. FH, BOLLARDS,VALVE9EX. FH, BOLLARDS,VALVE2222EX. CELL SITE1EX. TRASH ENCL1231EX. FIRE LINEEX. BUILDING11EX. FIRE LINE1EX. FIRE LINE1EX. TELEPHONE1EX. ELEC1EX.DRYWELLEX. BUILDING18APPROX. LOCATIONEX. IRRIGATION766666654C.V.W.D. STORM WATER CHANNELSTRAND ENGINEERING, INC.1001 Avenida Pico, Ste. C-121, San Clemente, CA 92673 (949) 431-0610C:\Users\stran\OneDrive\Projects\1012 Extra Space 1561 La Quinta\Engineering\ConDocs\Sheet-Files\1012-DM.dwg, DEMO, Aug 16, 2021 4:22pm, stranKnow what'sbelow.before you dig.CallREXTRA SPACE STORAGE2795 EAST COTTONWOOD PARKWAYSUITE 400SALT LAKE CITY, UT 841210204060feet1"=20'10DEMOLITION KEYNOTES1APPROXIMATE LIMIT OF SAWCUT2REMOVE AND DISPOSE OF EX. AC PAVEMENT3PROTECT IN PLACE EXISTING ITEM INDICATED.LEGENDDEMOLITION PLANREMOVE AND DISPOSE OF EX. CONC. VALLEY GUTTER4REMOVE AND DISPOSE OF EX. FIRE LINE5REMOVE AND DISPOSE OF EX. PARKING LIGHT AND POWER SUPPLY61. DEMOLITION LIMITS AND DESCRIPTIONS ARE APPROXIMATE. VERIFY EXISTINGSITE CONDITIONS AND INVESTIGATE EXISTING CONDITIONS AS REQUIRED TOPROPERLY COORDINATE PROPOSED IMPROVEMENTS WITH EXISTINGCONDITIONS.2.CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO START OFCONSTRUCTION.3.CONTRACTOR SHALL HAVE UTILITIES LOCATED WITHIN THE LIMITS OF WORKPRIOR TO THE START OF DEMOLITION. CONTRACTOR SHALL NOTIFY ENGINEEROF ANY POTENTIAL CONFLICTS.4.DEMOLITION AND REMOVALS SHALL INCLUDE ALL ITEMS IDENTIFIED FORDEMOLITION OR REMOVAL ON THIS SHEET AS WELL AS INCIDENTALDEMOLITION AND REMOVALS REQUIRED FOR CONSTRUCTION OF THEPROPOSED IMPROVEMENTS.5. CONTRACTOR SHALL PRESERVE AND PROTECT ALL EXISTING SITE FEATURESAND FACILITIES THAT ARE NOT SPECIFIED FOR DEMOLITION AND REMOVAL.6.CONTRACTOR SHALL INSTALL AND MAINTAIN ALL REQUIRED EROSION ANDSEDIMENTATION BMPS FOR THE DURATION OF THE PROJECT. CONTRACTORSHALL BE RESPONSIBLE FOR ANY RELATED FINES.7.CONTRACTOR IS RESPONSIBLE FOR PROPER REMOVAL AND DISPOSAL OF ALLDEMOLITION ITEMS.8.CONTRACTOR SHALL IMPLEMENT NECESSARY MEASURES AND SCHEDULING TOMINIMIZE IMPACT OF DEMOLITION WORK ON THE OPERATION OF THE EXISTINGSITE.9.ALL WORK TO CONFORM TO STANDARD SPECIFICATIONS FOR PUBLIC WORKSCONSTRUCTION (CURRENT EDITION) AS AMENDED BY THE CITY.GENERAL DEMOLITION NOTESCOORDINATE DEMOLITION LIMITS FOR CANOPY WITH CANOPY PLANS7EX. IRRIGATION LINE. PROTECT IN PLACE/RELOCATE.8REMOVE EX. HYDRANT, LATERAL TO VALVE, CLOSE VALVE, REMOVERISER, REMOVE VALVE BOX, BACKFILL TRENCH PER DETAIL H, SHEET 79 8" FIRE 95 LF 8" SD S=.0035 168 LF8" SDS=.003524" SDS=0.095 LF8" SDS=.0035 144 LF8" SDS=.003512" SD S=.002PROPOSED BUILDINGSLOPE FF11PROPOSED CARPORTFIRE SPRINKLERED23334PROPERTY LINEPROPERTY LINE PROPERTY LINE 5'7.5'5'5'5'53.4'C.V.W.D. STORM WATER CHANNEL5123456782.5'2.5'2.5'2.5'3'9101112131428'666W W W W W WWWW WWWW5'10'20'5'1516Point TablePoint #19234567810Raw DescriptionBLDGSDBLDGBLDGBLDGBLDGBLDGBLDGBLDGSDNorthing2202424.71722202453.18962202414.01452202354.01492202343.38442202344.43342202355.13612202415.13582202425.76632202453.7829Easting6551094.83526551086.73866551084.20476551084.40786551095.11056551405.10876551415.73926551415.53626551404.83356551262.0699Point TablePoint #111213141516Raw DescriptionCARPORTCARPORTCARPORTCARPORTFLFLNorthing2202548.37552202482.72632202455.29142202455.83752202446.27742202446.2069Easting6551086.83896551280.28196551264.56586551084.72966551260.34416551239.5158STRAND ENGINEERING, INC.1001 Avenida Pico, Ste. C-121, San Clemente, CA 92673 (949) 431-0610C:\Users\stran\OneDrive\Projects\1012 Extra Space 1561 La Quinta\Engineering\ConDocs\Sheet-Files\1012-UT.dwg, UTILITY, Aug 16, 2021 4:28pm, stranKnow what'sbelow.before you dig.CallREXTRA SPACE STORAGE2795 EAST COTTONWOOD PARKWAYSUITE 400SALT LAKE CITY, UT 84121WATER CONSTRUCTION NOTES1CONNECT TO EX. FIRE LINE WITH DIP MECH. JOINT WRAP IN POLYETHYLENE2INSTALL 8" POLYETHYLENE WRAPPED DIP CL150 FIRE LINE PER DETAIL H, SHEET 73EX. FIRE HYDRANT, VALVE, GUARD POSTS - PROTECT IN PLACEUTILITY/HORIZONTAL CONTROL PLAN0204060feet1"=20'10LEGEND1.CONTRACTOR TO CONFIRM PIPE SIZES AND LOCATIONS PRIOR TOCONSTRUCTION. 2.CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO START OF CONSTRUCTION.3.CONTRACTOR SHALL HAVE UTILITIES LOCATED WITHIN THE LIMITS OF WORKPRIOR TO THE START OF DEMOLITION. CONTRACTOR SHALL NOTIFY ENGINEEROF ANY POTENTIAL CONFLICTS.4.DEMOLITION AND REMOVALS SHALL INCLUDE ALL ITEMS IDENTIFIED FORDEMOLITION OR REMOVAL ON THIS SHEET AS WELL AS INCIDENTALDEMOLITION AND REMOVALS REQUIRED FOR CONSTRUCTION OF THEPROPOSED IMPROVEMENTS.5. CONTRACTOR SHALL PRESERVE AND PROTECT ALL EXISTING SITE FEATURESAND FACILITIES THAT ARE NOT SPECIFIED FOR DEMOLITION AND REMOVAL.SITE FEATURES DAMAGED BY CONTRACTOR SHALL BE REPAIRED OR REPLACEDAT CONTRACTOR'S EXPENSE.6.SITE KEYNOTE IMPROVEMENTS SHALL INCLUDE ALL ANCILLARY ITEMSNECESSARY FOR CONSTRUCTION IN THE UNIT COST.7.SITE FEATURES DESIGNATED FOR REMOVAL AND REPLACEMENT WHICH AREDAMAGED DURING REMOVAL SHALL BE REPLACED AT CONTRACTOR'SEXPENSE.8.CONTRACTOR SHALL INSTALL AND MAINTAIN ALL REQUIRED EROSION ANDSEDIMENTATION BMPS FOR THE DURATION OF THE PROJECT. CONTRACTORSHALL BE RESPONSIBLE FOR ANY RELATED FINES.9.CONTRACTOR IS RESPONSIBLE FOR PROPER REMOVAL AND DISPOSAL OF ALLDEMOLITION ITEMS.10.CONTRACTOR SHALL IMPLEMENT NECESSARY MEASURES AND SCHEDULING TOMINIMIZE IMPACT OF DEMOLITION WORK ON THE OPERATION OF THE EXISTINGSITE.11.ALL WORK TO CONFORM TO STANDARD SPECIFICATIONS FOR PUBLIC WORKSCONSTRUCTION (CURRENT EDITION) AS AMENDED BY THE CITY AND THECOACHELLA VALLEY WATER DISTRICT STANDARDS (CURRENT EDITION).GENERAL WATER NOTES4REMOVE EX. FIRE HYDRANT, LATERAL TO VALVE, CLOSE VALVE, REMOVERISER, REMOVE VALVE BOX, BACKFILL TRENCH PER DETAIL H, SHEET 75CONSTRUCT 4" POLYETHYLENE WRAPPED DIP FIRE RISER SERVICE W/BOLLARDS, 8"X4" TEE & GATE VALVE PER DETAIL L, SHEET 71. THIS HORIZONTAL CONTROL PLAN IS PROVIDED AS A COURTESY TO THE CONTRACTOR. ALL DIMENSIONS AND COORDINATES SHALL BE VERIFIED PRIOR TO CONSTRUCTION.2. THE CONTRACTOR SHALL HIRE A COMPETENT SURVEYOR TO PROVIDE CONSTRUCTION STAKING. THE SURVEYOR SHALL REVIEW THE PLANS AND ALERT THE ENGINEER OF ANY DISCREPANCIES IN ADVANCE OF STAKING TOALLOW THE ENGINEER ADEQUATE TIME TO PREPARE A RESPONSE.3. THE PROJECT CONTAINS BUILT ITEMS THAT ARE INCLUDED ON SEVERAL SETSOF PLANS (BUILDINGS, CARPORT, LIGHTING, MECHANICAL ETC.). THE CONTRACTOR AND HIS SURVEYOR SHALL REVIEW ALL SETS OF PLANS FOR CONFLICTS PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER OF ANYCONFLICTS IN ADVANCE OF STAKING TO ALLOW THE ENGINEER OR OTHER DESIGN PROFESSIONAL ADEQUATE TIME TO PREPARE A RESPONSE.HORIZONTAL CONTROL NOTESPRIVATE FIRE MAIN DETAILS PRESENTED HERE ARE "CONCEPTUAL ONLY" ASSEPARATE DEFERRED SUBMITTAL TO THE LQ OFFICE OF THE MARSHAL IS REQUIRED.6INSTALL TYPE C BLUE REFLT. MARKER, CEMENT W/ HOTMELT BITUMEN ADHESIVE STRAND ENGINEERING, INC.1001 Avenida Pico, Ste. C-121, San Clemente, CA 92673 (949) 431-0610C:\Users\stran\OneDrive\Projects\1012 Extra Space 1561 La Quinta\Engineering\ConDocs\Sheet-Files\1012-DT.dwg, DETAILS, Aug 16, 2021 4:29pm, stranKnow what'sbelow.before you dig.CallREXTRA SPACE STORAGE2795 EAST COTTONWOOD PARKWAYSUITE 400SALT LAKE CITY, UT 84121CONC. VALLEY GUTTER4" MIN 12" MIN 34" CRUSHED, WASHEDROCK.BACKFILL ZONE SHALLBE COMPACTED TO AMINIMUM 90%COMPACTION.NON-WOVENGEOTEXTILE FABRIC,OVERLAP 12"24" PERFORATEDHDPE3'6" P.C.C.4" CLASS II A.B. COMPACTED TO95% RELATIVE DENSITYSCARIFY 12" AND COMPACT TO90% RELATIVE DENSITY2-#4 BARS1" TO 3'1.5'BVALLEY GUTTERN.T.S.3" AC4" CLASS II A.B. COMPACTED TOMIN. 95% RELATIVE DENSITY12" COMPACTED SUBGRADE TOMIN. 90% RELATIVE DENSITYCAC PAVEMENT SECTIONN.T.S.AREM TR14CR(32) FILTER W/ MEDIAN.T.S.FDRYWELLN.T.S.DINFILTRATION TRENCHN.T.S.4" DOWNSPOUT PER ARCHITECTURAL6" PVC DRAINCONNECT TO STORMDRAIN1% MIN90° ELBOWEDOWNSPOUT CONNECTIONN.T.S.12" DIA PERFORATED PVC PIPE3/4" CRUSHED WASHED ROCK30"24"8"X12" PVC REDUCERPCC COLLAR, 560-C-3250BINGHAM & TAYLORCLEANOUT BOX NO. 76218" PVC PIPE6"PVC COND DRAINLINE FROM BUILDINGSEE PLANS FOR SIZELINE DRYWELL W/ MIRIFI 140N24"DETAILSFINISH SURFACE45° BENDNOTES:1.CHIMNEY SIZE AND CONNECTIONS SHALLBE 8".2.PIPE AND FITTINGS SHALL BE PVC3.BEDDING AND BACKFILL SHALL BE THESAME AS FOR STORM DRAIN MAIN.PROPOSED STORM DRAINVARIES VARIES 45° WYEGSTORM DRAIN CLEAN OUTN.T.S.BINGHAM & TAYLORCLEANOUT BOX NO. 7621PCC COLLAR, 560-C-32508" PVC PIPEA A SECTION A-APLAN24" MIN 12" MIN42" MINPCC, 560-C-3200JTHRUST BLOCKSN.T.S.UNDISTURBED SOILSHORING AND BRACING OF TRENCH IS THERESPONSIBILITY OF THE CONTRACTOR ANDSHALL BE IN COMPLIANCE WITH ALLAPPLICABLE CALIFORNIA SAFETY LAWSAC PAVEMENT SEEDETAIL THIS SHEET12" COMPACTED SUBGRADE TOMIN. 90% RELATIVE DENSITYFILL SAND OR PEAGRAVEL3' MINNOTE:TRENCH BACKFILL SHALL MEET REQUIREMENTS OF NFPA 24: 10.9.1 AS AMENDED BY CA FIRE CODE.BACKFILL SHALL BE WELL TAMPED IN LAYERS OR PUDDLE UNDER AND AROUND PIPES TO PREVENTSETTLEMENT OR LATERAL MOVEMENT. BACKFILL SHALL CONSIST OF CLEAN FILL SAND OR PEA GRAVELTO A MINIMUM 6" BELOW AND TO A MINIMUM 12" ABOVE PIPE AND SHALL CONTAIN NO ASHES,CINDERS, REFUSE, ORGANIC MATTER, OR OTHER CORROSIVE MATERIALS. OTHER BACKFILL MATERIALSAND METHODS ARE PERMITTED WHERE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER ANDAPPROVED BY THE ENFORCING AGENCY.HTRENCH DETAILN.T.S.PAINT WITH TWO COATS FIRE ENGINE REDTWO 3" BANDS OF REFLECTIVE WHITE TAPEKBOLLARDN.T.S.PCC, 560-C-320012"30" 6"THRUST BLOCK, SEE DETAILTHIS SHEETCLOW 860 HYDRANTCLOW LP619 BREAK-OFFCHECK VALVECHRISTY G8 TRAFFIC VALVE BOX.CAST IRON COVER & RIMINSCRIBED "FIRE"6" GATE VALVE WITHFLANGE & R.T. FITTINGSTHRUST BLOCK, SEE DETAILTHIS SHEET6" POLY WRAPPED DIP11"8"PCC, 560-C-3200TYPE C BLUE REFLT. MARKERCEMENT W/ HOTMELT BITUMEN ADHESIVEIFIRE HYDRANTN.T.S.TEE W/ 6" FLANGE & R.T.FITTINGS12" PVC SDR35 RISERLFIRE RISERN.T.S.SYSTEM RISERSEE FIRE SPRINKLERPLANS FOR DETAILS4" DIP CLASS 150POLY WRAPPEDJOINT RESTRAINTPAVEMENTDIP FLANGE AND SPIGOTPIECE, POLY WRAPBELOW GRADEFOOTINGCALCULATIONS:SANDY SILT (3,000 PSI)WORKING PRESSURE 150 PSI, SF 1.5MIN HORIZONTAL BEARING AREA FOR 8" MAIN (90°) 6.8 SFPER THRUST BLOCK SPREADSHEET10' MINIMUM12"6"2-BOLLARDS PERDETAIL K THISSHEET3' MIN Near-Cal Corp. 512 Chaney Street Lake Elsinore, California 92530 P: (951) 245-5400 Project: 2108 ESS LA QUINTA - 1561 46600 ADAMS ST LA QUINTA, California 92253     Submittal #6.0 - ESS LA QUINTA - 6-02500-0 UNDER GROUND UTILITIES SUBMITTAL   Revision 0 Submittal Manager Marilyn Jarvis (Near-Cal Corp.) Status Open Date Created Sep 8, 2021 Issue Date Sep 8, 2021 Spec Section Responsible Contractor INLAND VALLEY PIPELINE, INC.Received From JAIME BAHR (INLAND VALLEY PIPELINE, INC.) Received Date Sep 8, 2021 Submit By Sep 9, 2021 Final Due Date Sep 23, 2021 Lead Time Cost Code Location Type Product Information Approvers Marilyn Jarvis (Near-Cal Corp.), JEFF GOODMAN (JAMES GOODMAN ARCHITECTURE) Ball in Court JEFF GOODMAN (JAMES GOODMAN ARCHITECTURE) Distribution Kevin Tait (Near-Cal Corp.), Rick Rodriguez (NEAR-CAL CORP), JAMES GOODMAN (JAMES GOODMAN ARCHITECTURE), MARK GLASMIRE (EXTRA SPACE STORAGE) Description     Submittal Workflow Name Sent Date Due Date Returned Date Response Attachments General Information Attachments      EXTRA SPACE SUBS.pdf  JAIME BAHR Sep 8, 2021 Sep 9, 2021 Sep 8, 2021 Submitted EXTRA SPACE SUBS.pdf   Marilyn Jarvis Sep 8, 2021 Sep 16, 2021 Sep 8, 2021 Approved EXTRA SPACE SUBS.pdf (Current)  JEFF GOODMAN Sep 8, 2021 Sep 23, 2021  Pending     Near-Cal Corp.Page 1 of 1 Printed On: Sep 9, 2021 09:49 AM PDT    CONTACT JAIME BAHR PROJECT EXTRA SPACE LOCATION EXTRA SPACE - - AGENCY START DATE BOOK DATE 08/30/2021 PREPARED BY ALEX DENNIS TABLE OF CONTENTS 8in CL350 Ductile Iron Tyton-Joint Pipe CML with Gasket DI C153 8in MJ 45 Bend MJ Restraints with Accessories DI Pipe - Star FIRE HYDRANT DI C153 8x6in MJxFLG Tee 6in Mueller A-2362-19 E381 MJxFLG RW Gate Valve OL NDZ Stem 316 BN 6X48 DI 6-Hole PO Hydrant Bury CL with Gasket 6X24 DI 6-Hole Hydrant Extension Solid Without Groove CL ITP 6H Hydrant Break-Off Bolt & Nut Set A307 Zinc Plated Silicone Filled ITP Non-Asbestos NSF61 Ring Gasket 16th Inch Thick Clow LBI 400A 6 Break-Off Check Valve 6-Hole Low Lead STORM DRAIN WT PIPE Prinsco Goldflo HDPE Fittings Harco pvc_drain_basin_detail_sheet 2019-001 HARCO DEBRIS BAG DETAIL Layout1 PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 8in CL350 Ductile Iron Tyton-Joint Pipe CML with Gasket PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Smooth Running Jobs Ductile Iron Pipe ANSI/AWWA STANDARDS: PRESSURE CLASS 350 TYTON-JOINT® PIPE ANSI/AWWA C151/A21.5, Ductile Iron Pipe, Centrifugally Cast for Water. Ductile Iron Tyton Joint Pipe is centrifugally cast in metal molds in accordance with ANSI/ AWWA C151/A21.5. The asphaltic outside coating is in accordance with ANSI/AWWA C151/A21.51. ANSI/AWWA C111/A21.11 Standard for Rubber-Gasket Joints for Ductile Iron Pressure Pipe.The standard rubber compound is SBR – Styrene Butadiene Rubber. This material has a maximum service temperature rating of 150°F and is used as the predominant gasket material for Drinking Water, Sea Water, Sanitary Sewer, Reclaimed Water, Raw Water, & Storm Water. ANSI/AWWA C104/A21.4, Cement-Mortar Lining for Ductile-Iron Pipe and Fittings for Water. The cement-mortar lining and inside coating are in accordance with ANSI/AWWA C104/ A21.4. Special linings and/or coatings can be furnished for specific conditions. ANSI/AWWA C111/A21.11, Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings. Tyton Gaskets are furnished in accordance with ANSI/AWWA C111/A21.11. ANSI/AWWA C105/A21.5, Polyethylene Encasement for Ductile Iron Pipe Systems. If specifiers and users believe that corrosive soils will be encountered where our products are to be installed, please refer to ANSI/ AWWA C105/A21.5, for proper external protection procedures. ASTM A536 "Standard Specification for Ductile Iron Castings." Tyton joint pipe is NSF/ANSI 61 Certified for drinking water system components. MADE IN U.S.A. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS DI C153 8in MJ 45 Bend PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. IMPORT DUCTILE IRON MJ COMPACT FITTINGS ANSI/AWWA C153/A21.53 Ductile Iron per ASTM A536. *Flanged fittings rated at 250 psi. Mechanical joints 2” – 24” rated at 350 psi and 30” – 48” at 250 psi. *Note: With rubber annular ring flange gasket, 2” – 24” Flanged fittings can be rated at 350 psi. In accordance with ANSI/AWWA C153/A21.53 and UL Requirement. In accordance with ANSI/AWWA C153/A21.53. Fittings not listed in ANSI/AWWA have dimensions per as noted in Catalog. Do not include Accessories, Cement Lining and Coatings. Flanged ends on Fittings match ANSI/AWWA C115/A21.15 and ANSI B16.1 CLASS 125 Flanges. In accordance with ANSI/AWWA C104/A21.4. Asphaltic Seal Coat inside and out in accordance with ANSI/AWWA C104/A21.4 ANSI/AWWA C111/ A21.11. Compounded for water and sewer, NSF 61 Certified. Low Alloy Steel in accordance with ANSI/AWWA C111/A21.11. 3”- 24” Underwriters Laboratories Listed and UL/NSF 61. MATERIAL : PRESSURE : TESTING : LAYING LENGTH : GENERAL SPECIFICATIONS Smooth Running Jobs WEIGHTS : FLANGES : CEMENT LINING : COATING : GASKETS : T-BOLTS/NUTS : APPROVALS : PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS MJ Restraints with Accessories DI Pipe - Star PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. RESTRAINTS Stargrip® Mechanical Joint Wedge Action Restraint for DI Pipe Smooth Running Jobs Visit: www.starpipeproducts.com for more information Product Features • Gland is made from high strength Ductile Iron per ASTM A536, Grade 65-45-12 and is compatible with all Mechanical Joints conforming to ANSI/AWWA C111/A21.11. •A standard MJ gasket is used with this fitting. Meets ANSI/AWWA C111/A21.11 for gasket specs. •3/4” UNC T-bolts, heavy hex nuts, high strength, low alloy steel per AWWA C111. • The Wedge Assembly is designed with a Break-Off Torque Control Head, ensuring proper installation. • The Stargrip® offers a full 5° deflection through 12" size, 3° on 14"-24", 2° on 30"-36" and 1° on 42"-48". • Minimum safety factor of 2:1 • Stargrip® sizes 3"-36" are listed with Underwriters Laboratories Inc. and sizes 3"-12" are approved by Factory Mutual Research. • The Wedges are heat treated to a minimum of 370 BHN. • The Wedge Assembly is designed to fit specific pipe sizes. • Stargrip® eliminates tie rods and thrust blocks. • Standard gland color is Black. • Stargrip® may also be used on steel pipe* up to 12" (*transition gasket required on 12" and under). For 14" and larger steel applications, contact Star Pipe. STARGRIP for DUCTILE IRON PIPE ACCESSORY PACK (Stargrip, Gasket, Bolts and Nuts) FIRE HYDRANT PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS DI C153 8x6in MJxFLG Tee PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. IMPORT DUCTILE IRON MJ COMPACT FITTINGS ANSI/AWWA C153/A21.53 Ductile Iron per ASTM A536. *Flanged fittings rated at 250 psi. Mechanical joints 2” – 24” rated at 350 psi and 30” – 48” at 250 psi. *Note: With rubber annular ring flange gasket, 2” – 24” Flanged fittings can be rated at 350 psi. In accordance with ANSI/AWWA C153/A21.53 and UL Requirement. In accordance with ANSI/AWWA C153/A21.53. Fittings not listed in ANSI/AWWA have dimensions per as noted in Catalog. Do not include Accessories, Cement Lining and Coatings. Flanged ends on Fittings match ANSI/AWWA C115/A21.15 and ANSI B16.1 CLASS 125 Flanges. In accordance with ANSI/AWWA C104/A21.4. Asphaltic Seal Coat inside and out in accordance with ANSI/AWWA C104/A21.4 ANSI/AWWA C111/ A21.11. Compounded for water and sewer, NSF 61 Certified. Low Alloy Steel in accordance with ANSI/AWWA C111/A21.11. 3”- 24” Underwriters Laboratories Listed and UL/NSF 61. MATERIAL : PRESSURE : TESTING : LAYING LENGTH : GENERAL SPECIFICATIONS Smooth Running Jobs WEIGHTS : FLANGES : CEMENT LINING : COATING : GASKETS : T-BOLTS/NUTS : APPROVALS : PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6in Mueller A-2362-19 E381 MJxFLG RW Gate Valve OL NDZ Stem 316 BN PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. GATE VALVES 3"-12" A-2362 RW GATE VALVES MJ X FLG This information is based on the best data available at the date printed above. Please check with www.muellercompany.com for any updates or changes. 6" MJ x FLG RW GATE VALVE OPEN LEFT NDZ STEM T316 SS HARDWARE Smooth Running Jobs SPECIFICATIONS: Meets or exceeds all applicable requirements of ANSI/AWWA C509 and C515, UL Listed, FM Approved, and certified to ANSI/NSF 61 & 372. Standard Mechanical Joint ends comply with ANSI/AWWA C111 Flanged Ends (2” thru 12”) with flange drilling complying to ANSI B16.1 Class 125 Ductile Iron body with nominal 10 mils MUELLER® Pro-Gard® Fusion Epoxy Coated interior and exterior surfaces Epoxy coating meets or exceeds all applicable requirements of ANSI/AWWA C550 Standard and is certified to ANSI/NSF Standard 61 Ductile Iron wedge, symmetrical & fully encapsulated with molded *EPDM Rubber; no exposed iron Stem non-rising (NRS) Manganese **Bronze, ASTM B138 Alloy C67600 Triple O-ring seal stuffing box (2 upper & 1 lower O-rings) with fourth o-ring serving as dirt seal *EPDM Rubber 2" square wrench nut-open left *Bolts & Nuts for stuffing box and bonnet Type 316 Stainless Steel 350 psig (2400 kPa/24 barg) maximum working pressure, 700 psig (4800 kPa/48 barg) static test pressure UL Listed, FM Approved: 350 psig (2400 kPa/24 barg) Mueller valves are designed for potable water application **Bronze components meet current lead-free requirements A-2362-19 *E381 MANUFACTURED IN THE U.S.A. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6X48 DI 6-Hole PO Hydrant Bury CL with Gasket PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Part Number Description Size POB648-6 D.I. 6-Hole PO Hydrant Bury C/L with Gasket 6" x 48" Smooth Running Jobs Fire Hydrant Burys & Extension Spools Short Form Specification: Casting : As per ANSI/AWWA C153/A21.53Material : Ductile Iron per ASTM A536Cement Lining : As per ANSI/AWWA C104/A21.4, 1/8" thickness minimum Coating : Standard NSF-61 approved asphaltic coating inside-out Pressure Rating : 350 PSI hydrostatic pressure PUSH-ON HYDRANT BURYS Quality Manufacturers Since 1960 SIP Industries PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6X24 DI 6-Hole Hydrant Extension Solid Without Groove CL PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Part Number Description Size HE-624-6S D.I. 6-Hole Hydrant Extension Solid Without Groove C/L 6" x 24" Smooth Running Jobs Fire Hydrant Burys & Extension Spools Short Form Specification: HYDRANT SOLID EXTENSIONS 1.All Radii and Fillets to be 0.12 unless otherwise specified 2.PART NO letter size 0.31" high and 0.13" Raised 3.HEAT CODE and INDIA letter size 0.25" high and 0.13" Raised 4.Manufactured in accordance with AWWA Standard C-110 5.Extensions are Cement Lining in accordance with AWWA standard C-104 6.Meets ANSI/AWWA C110/A21.10 Specification 7.Cement Lined & Tar Coated per ANSI/AWWA C104/A21.4 8.Meets 250 PSI Water Working Pressure (CLASS 250) Quality Manufacturers Since 1960 SIP Industries PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS ITP 6H Hydrant Break-Off Bolt & Nut Set A307 Zinc Plated Silicone Filled PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. BOLTS & NUTS Smooth Running Jobs HEX HYDRANT BREAK-OFF BOLTS A307 GRADE A SUBMITTAL SPECIFICATIONS Abstract of ASTM A307 Grade A Grade: Low Carbon Steel 60,000 PSI **NOTE: These bolts have been altered to allow for shearing at the joint on impact. CHEMICAL REQUIREMENTS Chemical analysis shall be performed in accordance with ASTM A751 CARBON MAX MANGANESE MAX PHOPHOROUS MAX SULFER MAX 0.29 0.90 0.04 0.15 MECHANICAL REQUIREMENTS *Prior to drilling HARDNESS BRINEL MIN MAX HARDNESS ROCKWELL MIN MAX TENSILE STRENGTH (KSI) MIN MAX ELONGATION IN 2 IN (50MM) MIN 121 241 69 100 60 - 18 Hex Nuts ASTM A563 (ASME B18.2.2) Heavy hex Nuts ASTM A563 (ASME B18.2.2) Washers ASTM F844-90 FINISH Plain Zinc Plated Hot Dip Galvanized Cad Plated DIMENSIONAL DATA: Unless otherwise specified, threads shall be the coarse threaded series as specified in the latest issue of ANSI / ASME B1.1, page A-26. Class 2A tolerance. Grade A Bolts shall have Hex Bolt Dimensions as given in the latest issue of ANSI / ASME B 18.2.1 page C1. Unless otherwise specified Grade A Bolts should be used with Hex Nuts. ADDITIONAL INFORMATION: Additional information can be found in ASTM A307 DTD 2001, ASTM A563, DTD 2001 ADDITIONAL INFORMATION: Break Off Bolts have a drilled hole in the shank. Dimensions are 11/32 Hole for 5/8 Bolts; 13/32 for 3/4 Bolt. Hole Depth is 2 3/8”. OTHER: BOLTS ARE FILLED WITH SILICONE. BREAK-OFF BOLTS HAVE A HOLE DRILLED IN THE SHANK WITH THE DIMENSIONS OF 11/32 INCH (FOR 5/8” BOLTS) AND 13/32 INCH (FOR ¾” BOLTS) AND 2 3/8 INCHES DEEP. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS ITP Non-Asbestos NSF61 Ring Gasket 16th Inch Thick PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. FLANGE GASKETS TEADIT NA 1082SAN NSF61 APPROVED NON ASBESTOS GASKET Smooth Running Jobs SUBMITTAL SPECIFICATIONS GASKETS MEET THE PRESSURE RATINGS, DRILLING AND DIMENSIONS OF ANSI/ASME B16.21 AND AWWA C111 NSF 61 CERTIFIED FOR CHLORINATED POTABLE WATER TECHNICAL DATA MANUFACTURES STYLE COLOR BINDER TEMP MAX HARDNESS SHORE A TENSILE STRENGTH ASTM F- 152 ELONGATION APPLICATION CERTIFICATION MATERIAL Teadit. NA1082SAN Blue Proprietary 752 N/A 1885 N/A Potable Water Systems NSF 61 Non Asbestos Full Face Ring 1/16” 1/8” GENERAL DESCRIPTION: Teadit style NA1002SAN is specifically formulated to pass criteria established in NSF-61 for sealing materials, as well as providing excellent resistance to conductivity. ** Domestically manufactured in the USA** PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS Clow LBI 400A 6 Break-Off Check Valve 6-Hole Low Lead PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Refer to www.clowvalve.com for more information Part Number Description Size LBI 400A Break-Off Check Valve 6-Hole Low Lead 6" Smooth Running Jobs Clow LBI 400A Break-Off Check Valve The Clow LBI 400A is an efficient means for preventing the loss of water when a hydrant has been knocked off its mounting. A double-groove extension riser controls the break point enabling the bury to be protected during impact. As the break occurs, upward movement of a secured threaded stainless steel rod automatically releases a spring-loaded bronze valve flapper into the waterway. In static operation the valve flapper is housed in a recessed area out of the waterway.ea The Clow LBI 400A can easily be installed with any wet barrel fire hydrant regardless of model or manufacturer. Any bolt-hole pattern may be ordered upon request. All Clow LBI 400A are made standard with protective fusion epoxy lining. Conservation sensitive areas will also recognize the opportunity to reduce water losses by specifying the Clow LBI 400A . A hydrant broken from a 6” line under normal operating pressures can quickly result in large and highly visible water losses as indicated by the flow table below. TYPICAL FLOW RATES FOR A 6” LINE STORM DRAIN PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS WT PIPE PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Page 1 of 2 1717 16th St NE | Willmar, MN 56201 | 800.992.1725 | www.prinsco.com © Prinsco, Inc. 01/18 GOLDFLO WT® DUAL WALL SPECIFICATION Scope This specification designates the requirements for 4- through 60- inch I.D. Prinsco GOLDFLO WT® pipe for use in gravity-flow drainage applications. Pipe Requirements Prinsco GOLDFLO WT pipe shall have annular exterior corrugations with a smooth interior allowing for a Manning’s “n” design value of 0.012 and shall meet the following standards:  4- though 10- inch shall meet AASHTO M252, Type S  12- through 60- inch shall meet ASTM F2306 or AASHTO M294, Type S Materials GOLDFLO WT pipe and fabricated fittings shall be manufactured using High Density Polyethylene (HDPE) meeting the minimum requirements of cell classification of 424420C for 4- through 10- inch diameters and 435400C for 12- through 60- inch diameters, as defined and described in ASTM D3350 except the carbon black content shall be 2 – 4%. The HDPE pipe material for 12- through 60- inch diameters shall be tested for slow crack growth resistance using the notched constant ligament-stress (NCLS) test as specified in sections 9.4 and 5.1 of AASHTO M294 and ASTM F2306, respectively. Average failure time of the five test specimens shall not be less than 24 hours. Joint Performance GOLDFLO WT pipe shall be joined using watertight bell and spigot type joints meeting AASHTO M252, M294 or ASTM F2306. The integral joints shall be watertight according to ASTM D3212. Gaskets shall meet the requirements of ASTM F477 and shall be installed by the manufacturer. An approved joint lubricant, available from the manufacturer, shall be applied to the bell and gasket during installation. GOLDFLO WT joints shall be assembled in accordance with the manufacturer’s requirements to ensure installed watertight performance. Fittings Fittings shall meet the requirements of AASHTO M252, M294 or ASTM F2306. Standard fittings are available as listed on Prinsco’s website www.prinsco.com and custom fittings may be fabricated to customer specific requirements. Physical Pipe Dimensions Nominal ID (in) Approximate OD (in) Length (ft) Corrugation Pitch (in) Approximate Weight/foot (lb) Min. Pipe Stiffness @ 5% Deflection (psi) 4” 4.8 20 .67 0.5 50 6” 7.1 20 .80 1.0 50 8” 9.5 20 1.00 1.7 50 10” 11.9 20 1.30 2.3 50 12” 14.4 10, 20 2.00 3.1 50 15” 17.6 10, 20 2.67 4.5 42 18” 21.5 11, 20 3.00 6.5 40 24” 28.2 11, 20 4.00 11.0 34 30” 34.7 11, 20 4.00 14.6 29 36” 40.6 11, 20 4.70/ 3.90* 19.0 22.5 42” 47.5 11, 20 6.00 25 21 48” 54.1 11, 20 6.00 30 20 60” 66.8 12, 20 5.90 40 15 *Contact your Prinsco sales representative to determine actual corrugation pitch. Page 2 of 2 1717 16th St NE | Willmar, MN 56201 | 800.992.1725 | www.prinsco.com © Prinsco, Inc. 01/18 GOLDFLO WT® DUAL WALL SPECIFICATION Installation Pipe and fittings shall be installed in accordance with ASTM D2321 and Prinsco’s published installation guidelines. Minimum cover heights for AASHTO H-25 loads shall be 12” for 4- through 48-inch diameter pipe and 18” for 60-inch pipe. The minimum cover shall be measured from the top of the pipe to the bottom of flexible pavement or to the top of rigid pavement. Contact your local Prinsco representative or visit www.prinsco.com for the latest installation guidelines. Reference Specifications This specification references the latest edition and revisions of the following standard specifications:  AASHTO M294 – Standard Specification for Corrugated Polyethylene Pipe, 300- to 1500-mm (12- to 60-in.) Diameter  AASHTO M 252 – Standard Specification for Corrugated Polyethylene Drainage Pipe  ASTM F2306 – Standard Specification for 12 to 60-in. (300 to 1500 mm) Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings for Gravity-Flow Storm Sewer and Subsurface Drainage Applications  ASTM D3350 – Standard Specification for Polyethylene Plastics Pipe and Fittings Materials  ASTM D477 – Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe  ASTM D3212 – Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals  ASTM D2321 – Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications  ASTM F2487 – Standard Practice for Underground Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene Pipelines PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS Prinsco Goldflo HDPE Fittings PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. ACCESSORIES: GOLDFLO WT®| GOLDFLO®| ECOFLO WT®20 GASkET FOR SNAP COUPLER Size Number 4" GFGSK04 6" GFGSK06 8" GFGSK08 10" GFGSK10 SOIL TIGhT SPLIT COUPLER Size Number 4" SC04 6" SC06 8" SC08 10" SC10 12" SC12 15" SC15H 18" SC18 24" SC24 30" SC30 36" SC36 ELBOW - 45° Size Number 4" GFE0445 6" GFE0645 8" GFE0845 10" GFE1045 12" GFE1245 15" GFE1545 18" GFE1845 24" GFE2445 30" GFE3045 36" GFE3645 42" GFE4245 48" GFE4845 60" GFE6045 ELBOW - 90° (3-Piece) Size Number 4" GFE0490 6" GFE0690 8" GFE0890 10" GFE1090 12" GFE1290 15" GFE1590 18" GFE1890 24" GFE2490 30" GFE3090 36" GFE3690 42" GFE4290 48" GFE4890 60" GFE6090 ELBOW - 90° (2-Piece) Size Number 4" GFE04902 6" GFE06902 8" GFE08902 10" GFE10902 12" GFE12902 15" GFE15902 18" GFE18902 24" GFE24902 30" GFE30902 36" GFE36902 42" GFE42902 48" GFE48902 60" GFE60902 ELBOW - 22.5° Size Number 4" GFE0422 6" GFE0622 8" GFE0822 10" GFE1022 12" GFE1222 15" GFE1522 18" GFE1822 24" GFE2422 30" GFE3022 36" GFE3622 42" GFE4222 48" GFE4822 60" GFE6022 mARmAC COUPLER Size Number 4" MM4 6" MM6 8" MM8 10" MM10 12" MM12 15" MM15 18" MM18 24" MM24 30" MM30 36" MM36 42" MM42 48" MM48 60" MM60 ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® NEW! GOLDLOKTM couplers from Prinsco! SOILTIGhT GOLDLOkTm COUPLER 24" GFSTS24 30" GFSTS30 36" GFSTS36 42" GFSTS42 48" GFSTS48 WATERTIGhT GOLDLOkTm COUPLER 24" GFWTS24 30" GFWTS30 36" GFWTS36 42" GFWTS42 48" GFWTS48 ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® 800.992.1725 | www.prinsco.com ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® 800.992.1725 | www.prinsco.com CROSS TEE Size Number 4" GFCT04 6" GFTC06 8" GFTC08 10" GFTC10 12" GFCT12 15" GFCT15 18" GFCT18 24" GFCT24 30" GFTC30 TEE Size Number 4" GFT0404 6" GFT0606 8" GFT0808 10" GFT1010 12" GFT1212 15" GFT1515 18" GFT1818 24" GFT2424 30" GFT3030 36" GFT3636 42" GFT4242 48" GFT4848 60" GFT6060 21 PRINSCO DUAL-WALL CATCh BASINS Made to project specifications, maximum height up to 8'. Size Number Unit 12" GFCB12 Each 15" GFCB15 Each 18" GFCB18 Each 24" GFCB24 Each 30" GFCB30 Each 36" GFCB36 Each 42" GFCB42 Each 48" GFCB48 Each 60" GFCB60 Each REDUCER (One-Step) Size Reducer 6" Avail. in 4" 8" Avail. in 4"-6" 10" Avail. in 4"-8" 12" Avail. in 4"-10" 15" Avail. in 4"-12" 18" Avail. in 4"-15" 24" Avail. in 4"-18" 30" Avail. 4"- 24" 36" Avail. 4"-30" 42" Avail. 10"-36" 48" Avail. 10"-42" 60" Avail. 10"-48" WYE - 45° Size Number 4" GFY0404 6" GFY0606 8" GFY0808 10" GFY1010 12" GFY1212 15" GFY1515 18" GFY1818 24" GFY2424 30" GFY3030 ACCESSORIES: GOLDFLO WT®| GOLDFLO®| ECOFLO WT®See next page. 22 REDUCING TEESACCESSORIES: GOLDFLO WT®| GOLDFLO®| ECOFLO WT®ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® 800.992.1725 | www.prinsco.com REDUCING WYES 6" 8" 10" 12" 15" 18" 24" 30" Size Number GFY0604 6" X 4" Wye GFY0804 8" X 4" Wye GFY0806 8" X 6" Wye GFY1004 10" X 4" Wye GFY1006 10" X 6" Wye GFY1008 10" X 8" Wye GFY1204 12" TO 4" Wye GFY1206 12" TO 6" Wye GFY1208 12" TO 8" Wye GFY1210 12" TO 10" Wye GFY1504 15" X 4" Wye GFY1506 15" X 6" Wye GFY1508 15" X 8" Wye GFY1510 15" X 10" Wye GFY1512 15" X 12" Wye GFY1804 18" X 4" Wye GFY1806 18" X 6" Wye GFY1808 18" X 8" Wye GFY1810 18" X 10" Wye GFY1812 18" X 12" Wye GFY1815 18" X 15" Wye GFY2404 24" X 4" Wye GFY2406 24" X 6" Wye GFY2408 24" X 8" Wye GFY2410 24" X 10" Wye GFY2412 24" X 12" Wye GFY2415 24" X 15" Wye GFY2418 24" X 18" Wye GFY3004 30" X 4" Wye GFY3006 30" X 6" Wye GFY3008 30" X 8" Wye GFY3010 30" X 10" Wye GFY3012 30" X 12" Wye GFY3015 30" X 15" Wye GFY3018 30" X 18" Wye 36" 42" 48" 60" Size Number GFY3604 36" X 4" Wye GFY3606 36" X 6" Wye GFY3608 36" X 8" Wye GFY3610 36" X 10" Wye GFY3612 36" X 12" Wye GFY3615 36" X 15" Wye GFY3618 36" X 18" Wye GFY3624 36" X 24" Wye GFY4204 42" X 4" Wye GFY4206 42" X 6" Wye GFY4208 42" X 8" Wye GFY4210 42" X 10" Wye GFY4212 42" X 12" Wye GFY4215 42" X 15" Wye GFY4218 42" X 18" Wye GFY4804 48" X 4" Wye GFY4806 48" X 6" Wye GFY4808 48" X 8" Wye GFY4810 48" X 10" Wye GFY4812 48" X 12" Wye GFY4815 48" X 15" Wye GFY4818 48" X 18" Wye GFY4824 48" X 24" Wye GFY6004 60" X 4" Wye GFY6006 60" X 6" Wye GFY6008 60" X 8" Wye GFY6010 60" X 10" Wye GFY6012 60" X 12" Wye GFY6015 60" X 15" Wye GFY6018 60" X 18" Wye GFY6024 60" X 24" Wye 10" 12" 15" 18" 24" 30" 36" SADDLE TEES Size Number GFST1004 10" TO 4" GFST1006 10" TO 6" GFST1008 10" TO 8" GFST1204 12" TO 4" GFST1206 12" TO 6" GFST1208 12" TO 8 " GFST1210 12" TO 10" GFST1504 15" X 4" GFST1506 15" X 6" GFST1508 15" X 8" GFST1510 15" X 10" GFST1512 15" X 12" GFST1804 18" X 4" GFST1806 18" X 6" GFST1808 18" X 8" GFST1810 18" X 10" GFST1812 18" X 12" GFST1815 18" X 15" GFST2404 24" X 4" GFST2406 24" X 6" GFST2408 24" X 8" GFST2410 24" X 10" GFST2412 24" X 12" GFST3004 30" X 4" GFST3006 30" X 6" GFST3008 30" X 8" GFST3010 30" X 10" GFST3012 30" X 12" GFST3604 36" X 4" GFST3606 36" X 6" GFST3608 36" X 8 " GFST3610 36" X 10" GFST3612 36" X 12" 6" 8" 10" 12" 15" 18" 24" Size Number GFT0604 6" TO 4" Tee GFT0804 8" TO 4" Tee GFT0806 8" TO 6" Tee GFT1004 10" TO 4" Tee GFT1006 10" TO 6" Tee GFT1008 10" TO 8" Tee GFT1204 12" TO 4" Tee GFT1206 12" TO 6" Tee GFT1208 12" TO 8" Tee GFT1210 12" TO 10" Tee GFT1504 15" TO 4" Tee GFT1506 15" TO 6" Tee GFT1508 15" TO 8" Tee GFT1510 15" TO 10" Tee GFT1512 15" TO 12" Tee GFT1804 18" TO 4" Tee GFT1806 18" TO 6" Tee GFT1808 18" TO 8" Tee GFT1810 18" TO 10" Tee GFT1812 18" TO 12" Tee GFT1815 18" TO 15" Tee GFT2404 24" TO 4" Tee GFT2406 24" TO 6" Tee GFT2408 24" TO 8" Tee GFT2410 24" TO 10" Tee GFT2412 24" TO 12" Tee Size Number GFT2415 24" TO 15" Tee GFT2418 24" TO 18" Tee GFT3004 30" TO 4" Tee GFT3006 30" TO 6" Tee GFT3008 30" TO 8" Tee GFT3010 30’’ TO 10" Tee GFT3012 30’’ TO 12" Tee GFT3015 30’’ TO 15" Tee GFT3018 30’’ TO 18" Tee GFT3024 30’’ TO 24" Tee GFT3604 36’’ TO 4" Tee GFT3606 36’’ TO 6" Tee GFT3608 36’’ TO 8" Tee GFT3610 36’’ TO 10" Tee GFT3612 36’’ TO 12" Tee GFT3615 36’’ TO 15" Tee GFT3618 36’’ TO 18" Tee GFT3624 36’’ TO 24" Tee GFT3630 36" TO 30" Tee GFT4206 42" TO 6" Tee GFT4208 42" TO 8" Tee GFT4210 42" TO 10" Tee GFT4212 42" TO 12" Tee GFT4215 42" TO 15" Tee GFT4218 42" TO 18" Tee GFT4224 42" TO 24" Tee 24" 30" 36" 42" Size Number GFT4230 42" TO 30" Tee GFT4236 42" TO 36" Tee GFT4804 48" TO 4" Tee GFT4806 48" TO 6" Tee GFT4808 48" TO 8" Tee GFT4810 48" TO 10" Tee GFT4812 48" TO 12" Tee GFT4815 48" TO 15" Tee GFT4818 48" TO 18" Tee GFT4824 48" TO 24" Tee GFT4830 48" TO 30" Tee GFT4836 48" TO 36" Tee GFT4842 48" T0 42" Tee GFT6004 60" TO 4" Tee GFT6006 60" TO 6" Tee GFT6008 60" TO 8" Tee GFT6010 60" TO 10" Tee GFT6012 60" TO 12" Tee GFT6015 60" TO 15" Tee GFT6018 60" TO 18" Tee GFT6024 60" TO 24" Tee GFT6030 60" TO 30" Tee GFT6036 60" TO 36" Tee GFT6042 60" TO 42" Tee GFT6048 60" TO 48" Tee 42" 48" 60" PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS Harco pvc_drain_basin_detail_sheet PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 2019-001 HARCO DEBRIS BAG DETAIL Layout1 PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. CONTACT JAIME BAHR PROJECT EXTRA SPACE LOCATION EXTRA SPACE - - AGENCY START DATE BOOK DATE 08/30/2021 PREPARED BY ALEX DENNIS TABLE OF CONTENTS 8in CL350 Ductile Iron Tyton-Joint Pipe CML with Gasket DI C153 8in MJ 45 Bend MJ Restraints with Accessories DI Pipe - Star FIRE HYDRANT DI C153 8x6in MJxFLG Tee 6in Mueller A-2362-19 E381 MJxFLG RW Gate Valve OL NDZ Stem 316 BN 6X48 DI 6-Hole PO Hydrant Bury CL with Gasket 6X24 DI 6-Hole Hydrant Extension Solid Without Groove CL ITP 6H Hydrant Break-Off Bolt & Nut Set A307 Zinc Plated Silicone Filled ITP Non-Asbestos NSF61 Ring Gasket 16th Inch Thick Clow LBI 400A 6 Break-Off Check Valve 6-Hole Low Lead STORM DRAIN WT PIPE Prinsco Goldflo HDPE Fittings Harco pvc_drain_basin_detail_sheet 2019-001 HARCO DEBRIS BAG DETAIL Layout1 PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 8in CL350 Ductile Iron Tyton-Joint Pipe CML with Gasket PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Smooth Running Jobs Ductile Iron Pipe ANSI/AWWA STANDARDS: PRESSURE CLASS 350 TYTON-JOINT® PIPE ANSI/AWWA C151/A21.5, Ductile Iron Pipe, Centrifugally Cast for Water. Ductile Iron Tyton Joint Pipe is centrifugally cast in metal molds in accordance with ANSI/ AWWA C151/A21.5. The asphaltic outside coating is in accordance with ANSI/AWWA C151/A21.51. ANSI/AWWA C111/A21.11 Standard for Rubber-Gasket Joints for Ductile Iron Pressure Pipe.The standard rubber compound is SBR – Styrene Butadiene Rubber. This material has a maximum service temperature rating of 150°F and is used as the predominant gasket material for Drinking Water, Sea Water, Sanitary Sewer, Reclaimed Water, Raw Water, & Storm Water. ANSI/AWWA C104/A21.4, Cement-Mortar Lining for Ductile-Iron Pipe and Fittings for Water. The cement-mortar lining and inside coating are in accordance with ANSI/AWWA C104/ A21.4. Special linings and/or coatings can be furnished for specific conditions. ANSI/AWWA C111/A21.11, Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings. Tyton Gaskets are furnished in accordance with ANSI/AWWA C111/A21.11. ANSI/AWWA C105/A21.5, Polyethylene Encasement for Ductile Iron Pipe Systems. If specifiers and users believe that corrosive soils will be encountered where our products are to be installed, please refer to ANSI/ AWWA C105/A21.5, for proper external protection procedures. ASTM A536 "Standard Specification for Ductile Iron Castings." Tyton joint pipe is NSF/ANSI 61 Certified for drinking water system components. MADE IN U.S.A. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS DI C153 8in MJ 45 Bend PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. IMPORT DUCTILE IRON MJ COMPACT FITTINGS ANSI/AWWA C153/A21.53 Ductile Iron per ASTM A536. *Flanged fittings rated at 250 psi. Mechanical joints 2” – 24” rated at 350 psi and 30” – 48” at 250 psi. *Note: With rubber annular ring flange gasket, 2” – 24” Flanged fittings can be rated at 350 psi. In accordance with ANSI/AWWA C153/A21.53 and UL Requirement. In accordance with ANSI/AWWA C153/A21.53. Fittings not listed in ANSI/AWWA have dimensions per as noted in Catalog. Do not include Accessories, Cement Lining and Coatings. Flanged ends on Fittings match ANSI/AWWA C115/A21.15 and ANSI B16.1 CLASS 125 Flanges. In accordance with ANSI/AWWA C104/A21.4. Asphaltic Seal Coat inside and out in accordance with ANSI/AWWA C104/A21.4 ANSI/AWWA C111/ A21.11. Compounded for water and sewer, NSF 61 Certified. Low Alloy Steel in accordance with ANSI/AWWA C111/A21.11. 3”- 24” Underwriters Laboratories Listed and UL/NSF 61. MATERIAL : PRESSURE : TESTING : LAYING LENGTH : GENERAL SPECIFICATIONS Smooth Running Jobs WEIGHTS : FLANGES : CEMENT LINING : COATING : GASKETS : T-BOLTS/NUTS : APPROVALS : PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS MJ Restraints with Accessories DI Pipe - Star PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. RESTRAINTS Stargrip® Mechanical Joint Wedge Action Restraint for DI Pipe Smooth Running Jobs Visit: www.starpipeproducts.com for more information Product Features • Gland is made from high strength Ductile Iron per ASTM A536, Grade 65-45-12 and is compatible with all Mechanical Joints conforming to ANSI/AWWA C111/A21.11. •A standard MJ gasket is used with this fitting. Meets ANSI/AWWA C111/A21.11 for gasket specs. •3/4” UNC T-bolts, heavy hex nuts, high strength, low alloy steel per AWWA C111. • The Wedge Assembly is designed with a Break-Off Torque Control Head, ensuring proper installation. • The Stargrip® offers a full 5° deflection through 12" size, 3° on 14"-24", 2° on 30"-36" and 1° on 42"-48". • Minimum safety factor of 2:1 • Stargrip® sizes 3"-36" are listed with Underwriters Laboratories Inc. and sizes 3"-12" are approved by Factory Mutual Research. • The Wedges are heat treated to a minimum of 370 BHN. • The Wedge Assembly is designed to fit specific pipe sizes. • Stargrip® eliminates tie rods and thrust blocks. • Standard gland color is Black. • Stargrip® may also be used on steel pipe* up to 12" (*transition gasket required on 12" and under). For 14" and larger steel applications, contact Star Pipe. STARGRIP for DUCTILE IRON PIPE ACCESSORY PACK (Stargrip, Gasket, Bolts and Nuts) FIRE HYDRANT PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS DI C153 8x6in MJxFLG Tee PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. IMPORT DUCTILE IRON MJ COMPACT FITTINGS ANSI/AWWA C153/A21.53 Ductile Iron per ASTM A536. *Flanged fittings rated at 250 psi. Mechanical joints 2” – 24” rated at 350 psi and 30” – 48” at 250 psi. *Note: With rubber annular ring flange gasket, 2” – 24” Flanged fittings can be rated at 350 psi. In accordance with ANSI/AWWA C153/A21.53 and UL Requirement. In accordance with ANSI/AWWA C153/A21.53. Fittings not listed in ANSI/AWWA have dimensions per as noted in Catalog. Do not include Accessories, Cement Lining and Coatings. Flanged ends on Fittings match ANSI/AWWA C115/A21.15 and ANSI B16.1 CLASS 125 Flanges. In accordance with ANSI/AWWA C104/A21.4. Asphaltic Seal Coat inside and out in accordance with ANSI/AWWA C104/A21.4 ANSI/AWWA C111/ A21.11. Compounded for water and sewer, NSF 61 Certified. Low Alloy Steel in accordance with ANSI/AWWA C111/A21.11. 3”- 24” Underwriters Laboratories Listed and UL/NSF 61. MATERIAL : PRESSURE : TESTING : LAYING LENGTH : GENERAL SPECIFICATIONS Smooth Running Jobs WEIGHTS : FLANGES : CEMENT LINING : COATING : GASKETS : T-BOLTS/NUTS : APPROVALS : PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6in Mueller A-2362-19 E381 MJxFLG RW Gate Valve OL NDZ Stem 316 BN PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. GATE VALVES 3"-12" A-2362 RW GATE VALVES MJ X FLG This information is based on the best data available at the date printed above. Please check with www.muellercompany.com for any updates or changes. 6" MJ x FLG RW GATE VALVE OPEN LEFT NDZ STEM T316 SS HARDWARE Smooth Running Jobs SPECIFICATIONS: Meets or exceeds all applicable requirements of ANSI/AWWA C509 and C515, UL Listed, FM Approved, and certified to ANSI/NSF 61 & 372. Standard Mechanical Joint ends comply with ANSI/AWWA C111 Flanged Ends (2” thru 12”) with flange drilling complying to ANSI B16.1 Class 125 Ductile Iron body with nominal 10 mils MUELLER® Pro-Gard® Fusion Epoxy Coated interior and exterior surfaces Epoxy coating meets or exceeds all applicable requirements of ANSI/AWWA C550 Standard and is certified to ANSI/NSF Standard 61 Ductile Iron wedge, symmetrical & fully encapsulated with molded *EPDM Rubber; no exposed iron Stem non-rising (NRS) Manganese **Bronze, ASTM B138 Alloy C67600 Triple O-ring seal stuffing box (2 upper & 1 lower O-rings) with fourth o-ring serving as dirt seal *EPDM Rubber 2" square wrench nut-open left *Bolts & Nuts for stuffing box and bonnet Type 316 Stainless Steel 350 psig (2400 kPa/24 barg) maximum working pressure, 700 psig (4800 kPa/48 barg) static test pressure UL Listed, FM Approved: 350 psig (2400 kPa/24 barg) Mueller valves are designed for potable water application **Bronze components meet current lead-free requirements A-2362-19 *E381 MANUFACTURED IN THE U.S.A. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6X48 DI 6-Hole PO Hydrant Bury CL with Gasket PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Part Number Description Size POB648-6 D.I. 6-Hole PO Hydrant Bury C/L with Gasket 6" x 48" Smooth Running Jobs Fire Hydrant Burys & Extension Spools Short Form Specification: Casting : As per ANSI/AWWA C153/A21.53Material : Ductile Iron per ASTM A536Cement Lining : As per ANSI/AWWA C104/A21.4, 1/8" thickness minimum Coating : Standard NSF-61 approved asphaltic coating inside-out Pressure Rating : 350 PSI hydrostatic pressure PUSH-ON HYDRANT BURYS Quality Manufacturers Since 1960 SIP Industries PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6X24 DI 6-Hole Hydrant Extension Solid Without Groove CL PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Part Number Description Size HE-624-6S D.I. 6-Hole Hydrant Extension Solid Without Groove C/L 6" x 24" Smooth Running Jobs Fire Hydrant Burys & Extension Spools Short Form Specification: HYDRANT SOLID EXTENSIONS 1.All Radii and Fillets to be 0.12 unless otherwise specified 2.PART NO letter size 0.31" high and 0.13" Raised 3.HEAT CODE and INDIA letter size 0.25" high and 0.13" Raised 4.Manufactured in accordance with AWWA Standard C-110 5.Extensions are Cement Lining in accordance with AWWA standard C-104 6.Meets ANSI/AWWA C110/A21.10 Specification 7.Cement Lined & Tar Coated per ANSI/AWWA C104/A21.4 8.Meets 250 PSI Water Working Pressure (CLASS 250) Quality Manufacturers Since 1960 SIP Industries PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS ITP 6H Hydrant Break-Off Bolt & Nut Set A307 Zinc Plated Silicone Filled PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. BOLTS & NUTS Smooth Running Jobs HEX HYDRANT BREAK-OFF BOLTS A307 GRADE A SUBMITTAL SPECIFICATIONS Abstract of ASTM A307 Grade A Grade: Low Carbon Steel 60,000 PSI **NOTE: These bolts have been altered to allow for shearing at the joint on impact. CHEMICAL REQUIREMENTS Chemical analysis shall be performed in accordance with ASTM A751 CARBON MAX MANGANESE MAX PHOPHOROUS MAX SULFER MAX 0.29 0.90 0.04 0.15 MECHANICAL REQUIREMENTS *Prior to drilling HARDNESS BRINEL MIN MAX HARDNESS ROCKWELL MIN MAX TENSILE STRENGTH (KSI) MIN MAX ELONGATION IN 2 IN (50MM) MIN 121 241 69 100 60 - 18 Hex Nuts ASTM A563 (ASME B18.2.2) Heavy hex Nuts ASTM A563 (ASME B18.2.2) Washers ASTM F844-90 FINISH Plain Zinc Plated Hot Dip Galvanized Cad Plated DIMENSIONAL DATA: Unless otherwise specified, threads shall be the coarse threaded series as specified in the latest issue of ANSI / ASME B1.1, page A-26. Class 2A tolerance. Grade A Bolts shall have Hex Bolt Dimensions as given in the latest issue of ANSI / ASME B 18.2.1 page C1. Unless otherwise specified Grade A Bolts should be used with Hex Nuts. ADDITIONAL INFORMATION: Additional information can be found in ASTM A307 DTD 2001, ASTM A563, DTD 2001 ADDITIONAL INFORMATION: Break Off Bolts have a drilled hole in the shank. Dimensions are 11/32 Hole for 5/8 Bolts; 13/32 for 3/4 Bolt. Hole Depth is 2 3/8”. OTHER: BOLTS ARE FILLED WITH SILICONE. BREAK-OFF BOLTS HAVE A HOLE DRILLED IN THE SHANK WITH THE DIMENSIONS OF 11/32 INCH (FOR 5/8” BOLTS) AND 13/32 INCH (FOR ¾” BOLTS) AND 2 3/8 INCHES DEEP. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS ITP Non-Asbestos NSF61 Ring Gasket 16th Inch Thick PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. FLANGE GASKETS TEADIT NA 1082SAN NSF61 APPROVED NON ASBESTOS GASKET Smooth Running Jobs SUBMITTAL SPECIFICATIONS GASKETS MEET THE PRESSURE RATINGS, DRILLING AND DIMENSIONS OF ANSI/ASME B16.21 AND AWWA C111 NSF 61 CERTIFIED FOR CHLORINATED POTABLE WATER TECHNICAL DATA MANUFACTURES STYLE COLOR BINDER TEMP MAX HARDNESS SHORE A TENSILE STRENGTH ASTM F- 152 ELONGATION APPLICATION CERTIFICATION MATERIAL Teadit. NA1082SAN Blue Proprietary 752 N/A 1885 N/A Potable Water Systems NSF 61 Non Asbestos Full Face Ring 1/16” 1/8” GENERAL DESCRIPTION: Teadit style NA1002SAN is specifically formulated to pass criteria established in NSF-61 for sealing materials, as well as providing excellent resistance to conductivity. ** Domestically manufactured in the USA** PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS Clow LBI 400A 6 Break-Off Check Valve 6-Hole Low Lead PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Refer to www.clowvalve.com for more information Part Number Description Size LBI 400A Break-Off Check Valve 6-Hole Low Lead 6" Smooth Running Jobs Clow LBI 400A Break-Off Check Valve The Clow LBI 400A is an efficient means for preventing the loss of water when a hydrant has been knocked off its mounting. A double-groove extension riser controls the break point enabling the bury to be protected during impact. As the break occurs, upward movement of a secured threaded stainless steel rod automatically releases a spring-loaded bronze valve flapper into the waterway. In static operation the valve flapper is housed in a recessed area out of the waterway.ea The Clow LBI 400A can easily be installed with any wet barrel fire hydrant regardless of model or manufacturer. Any bolt-hole pattern may be ordered upon request. All Clow LBI 400A are made standard with protective fusion epoxy lining. Conservation sensitive areas will also recognize the opportunity to reduce water losses by specifying the Clow LBI 400A . A hydrant broken from a 6” line under normal operating pressures can quickly result in large and highly visible water losses as indicated by the flow table below. TYPICAL FLOW RATES FOR A 6” LINE STORM DRAIN PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS WT PIPE PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Page 1 of 2 1717 16th St NE | Willmar, MN 56201 | 800.992.1725 | www.prinsco.com © Prinsco, Inc. 01/18 GOLDFLO WT® DUAL WALL SPECIFICATION Scope This specification designates the requirements for 4- through 60- inch I.D. Prinsco GOLDFLO WT® pipe for use in gravity-flow drainage applications. Pipe Requirements Prinsco GOLDFLO WT pipe shall have annular exterior corrugations with a smooth interior allowing for a Manning’s “n” design value of 0.012 and shall meet the following standards:  4- though 10- inch shall meet AASHTO M252, Type S  12- through 60- inch shall meet ASTM F2306 or AASHTO M294, Type S Materials GOLDFLO WT pipe and fabricated fittings shall be manufactured using High Density Polyethylene (HDPE) meeting the minimum requirements of cell classification of 424420C for 4- through 10- inch diameters and 435400C for 12- through 60- inch diameters, as defined and described in ASTM D3350 except the carbon black content shall be 2 – 4%. The HDPE pipe material for 12- through 60- inch diameters shall be tested for slow crack growth resistance using the notched constant ligament-stress (NCLS) test as specified in sections 9.4 and 5.1 of AASHTO M294 and ASTM F2306, respectively. Average failure time of the five test specimens shall not be less than 24 hours. Joint Performance GOLDFLO WT pipe shall be joined using watertight bell and spigot type joints meeting AASHTO M252, M294 or ASTM F2306. The integral joints shall be watertight according to ASTM D3212. Gaskets shall meet the requirements of ASTM F477 and shall be installed by the manufacturer. An approved joint lubricant, available from the manufacturer, shall be applied to the bell and gasket during installation. GOLDFLO WT joints shall be assembled in accordance with the manufacturer’s requirements to ensure installed watertight performance. Fittings Fittings shall meet the requirements of AASHTO M252, M294 or ASTM F2306. Standard fittings are available as listed on Prinsco’s website www.prinsco.com and custom fittings may be fabricated to customer specific requirements. Physical Pipe Dimensions Nominal ID (in) Approximate OD (in) Length (ft) Corrugation Pitch (in) Approximate Weight/foot (lb) Min. Pipe Stiffness @ 5% Deflection (psi) 4” 4.8 20 .67 0.5 50 6” 7.1 20 .80 1.0 50 8” 9.5 20 1.00 1.7 50 10” 11.9 20 1.30 2.3 50 12” 14.4 10, 20 2.00 3.1 50 15” 17.6 10, 20 2.67 4.5 42 18” 21.5 11, 20 3.00 6.5 40 24” 28.2 11, 20 4.00 11.0 34 30” 34.7 11, 20 4.00 14.6 29 36” 40.6 11, 20 4.70/ 3.90* 19.0 22.5 42” 47.5 11, 20 6.00 25 21 48” 54.1 11, 20 6.00 30 20 60” 66.8 12, 20 5.90 40 15 *Contact your Prinsco sales representative to determine actual corrugation pitch. Page 2 of 2 1717 16th St NE | Willmar, MN 56201 | 800.992.1725 | www.prinsco.com © Prinsco, Inc. 01/18 GOLDFLO WT® DUAL WALL SPECIFICATION Installation Pipe and fittings shall be installed in accordance with ASTM D2321 and Prinsco’s published installation guidelines. Minimum cover heights for AASHTO H-25 loads shall be 12” for 4- through 48-inch diameter pipe and 18” for 60-inch pipe. The minimum cover shall be measured from the top of the pipe to the bottom of flexible pavement or to the top of rigid pavement. Contact your local Prinsco representative or visit www.prinsco.com for the latest installation guidelines. Reference Specifications This specification references the latest edition and revisions of the following standard specifications:  AASHTO M294 – Standard Specification for Corrugated Polyethylene Pipe, 300- to 1500-mm (12- to 60-in.) Diameter  AASHTO M 252 – Standard Specification for Corrugated Polyethylene Drainage Pipe  ASTM F2306 – Standard Specification for 12 to 60-in. (300 to 1500 mm) Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings for Gravity-Flow Storm Sewer and Subsurface Drainage Applications  ASTM D3350 – Standard Specification for Polyethylene Plastics Pipe and Fittings Materials  ASTM D477 – Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe  ASTM D3212 – Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals  ASTM D2321 – Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications  ASTM F2487 – Standard Practice for Underground Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene Pipelines PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS Prinsco Goldflo HDPE Fittings PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. ACCESSORIES: GOLDFLO WT®| GOLDFLO®| ECOFLO WT®20 GASkET FOR SNAP COUPLER Size Number 4" GFGSK04 6" GFGSK06 8" GFGSK08 10" GFGSK10 SOIL TIGhT SPLIT COUPLER Size Number 4" SC04 6" SC06 8" SC08 10" SC10 12" SC12 15" SC15H 18" SC18 24" SC24 30" SC30 36" SC36 ELBOW - 45° Size Number 4" GFE0445 6" GFE0645 8" GFE0845 10" GFE1045 12" GFE1245 15" GFE1545 18" GFE1845 24" GFE2445 30" GFE3045 36" GFE3645 42" GFE4245 48" GFE4845 60" GFE6045 ELBOW - 90° (3-Piece) Size Number 4" GFE0490 6" GFE0690 8" GFE0890 10" GFE1090 12" GFE1290 15" GFE1590 18" GFE1890 24" GFE2490 30" GFE3090 36" GFE3690 42" GFE4290 48" GFE4890 60" GFE6090 ELBOW - 90° (2-Piece) Size Number 4" GFE04902 6" GFE06902 8" GFE08902 10" GFE10902 12" GFE12902 15" GFE15902 18" GFE18902 24" GFE24902 30" GFE30902 36" GFE36902 42" GFE42902 48" GFE48902 60" GFE60902 ELBOW - 22.5° Size Number 4" GFE0422 6" GFE0622 8" GFE0822 10" GFE1022 12" GFE1222 15" GFE1522 18" GFE1822 24" GFE2422 30" GFE3022 36" GFE3622 42" GFE4222 48" GFE4822 60" GFE6022 mARmAC COUPLER Size Number 4" MM4 6" MM6 8" MM8 10" MM10 12" MM12 15" MM15 18" MM18 24" MM24 30" MM30 36" MM36 42" MM42 48" MM48 60" MM60 ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® NEW! GOLDLOKTM couplers from Prinsco! SOILTIGhT GOLDLOkTm COUPLER 24" GFSTS24 30" GFSTS30 36" GFSTS36 42" GFSTS42 48" GFSTS48 WATERTIGhT GOLDLOkTm COUPLER 24" GFWTS24 30" GFWTS30 36" GFWTS36 42" GFWTS42 48" GFWTS48 ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® 800.992.1725 | www.prinsco.com ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® 800.992.1725 | www.prinsco.com CROSS TEE Size Number 4" GFCT04 6" GFTC06 8" GFTC08 10" GFTC10 12" GFCT12 15" GFCT15 18" GFCT18 24" GFCT24 30" GFTC30 TEE Size Number 4" GFT0404 6" GFT0606 8" GFT0808 10" GFT1010 12" GFT1212 15" GFT1515 18" GFT1818 24" GFT2424 30" GFT3030 36" GFT3636 42" GFT4242 48" GFT4848 60" GFT6060 21 PRINSCO DUAL-WALL CATCh BASINS Made to project specifications, maximum height up to 8'. Size Number Unit 12" GFCB12 Each 15" GFCB15 Each 18" GFCB18 Each 24" GFCB24 Each 30" GFCB30 Each 36" GFCB36 Each 42" GFCB42 Each 48" GFCB48 Each 60" GFCB60 Each REDUCER (One-Step) Size Reducer 6" Avail. in 4" 8" Avail. in 4"-6" 10" Avail. in 4"-8" 12" Avail. in 4"-10" 15" Avail. in 4"-12" 18" Avail. in 4"-15" 24" Avail. in 4"-18" 30" Avail. 4"- 24" 36" Avail. 4"-30" 42" Avail. 10"-36" 48" Avail. 10"-42" 60" Avail. 10"-48" WYE - 45° Size Number 4" GFY0404 6" GFY0606 8" GFY0808 10" GFY1010 12" GFY1212 15" GFY1515 18" GFY1818 24" GFY2424 30" GFY3030 ACCESSORIES: GOLDFLO WT®| GOLDFLO®| ECOFLO WT®See next page. 22 REDUCING TEESACCESSORIES: GOLDFLO WT®| GOLDFLO®| ECOFLO WT®ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® 800.992.1725 | www.prinsco.com REDUCING WYES 6" 8" 10" 12" 15" 18" 24" 30" Size Number GFY0604 6" X 4" Wye GFY0804 8" X 4" Wye GFY0806 8" X 6" Wye GFY1004 10" X 4" Wye GFY1006 10" X 6" Wye GFY1008 10" X 8" Wye GFY1204 12" TO 4" Wye GFY1206 12" TO 6" Wye GFY1208 12" TO 8" Wye GFY1210 12" TO 10" Wye GFY1504 15" X 4" Wye GFY1506 15" X 6" Wye GFY1508 15" X 8" Wye GFY1510 15" X 10" Wye GFY1512 15" X 12" Wye GFY1804 18" X 4" Wye GFY1806 18" X 6" Wye GFY1808 18" X 8" Wye GFY1810 18" X 10" Wye GFY1812 18" X 12" Wye GFY1815 18" X 15" Wye GFY2404 24" X 4" Wye GFY2406 24" X 6" Wye GFY2408 24" X 8" Wye GFY2410 24" X 10" Wye GFY2412 24" X 12" Wye GFY2415 24" X 15" Wye GFY2418 24" X 18" Wye GFY3004 30" X 4" Wye GFY3006 30" X 6" Wye GFY3008 30" X 8" Wye GFY3010 30" X 10" Wye GFY3012 30" X 12" Wye GFY3015 30" X 15" Wye GFY3018 30" X 18" Wye 36" 42" 48" 60" Size Number GFY3604 36" X 4" Wye GFY3606 36" X 6" Wye GFY3608 36" X 8" Wye GFY3610 36" X 10" Wye GFY3612 36" X 12" Wye GFY3615 36" X 15" Wye GFY3618 36" X 18" Wye GFY3624 36" X 24" Wye GFY4204 42" X 4" Wye GFY4206 42" X 6" Wye GFY4208 42" X 8" Wye GFY4210 42" X 10" Wye GFY4212 42" X 12" Wye GFY4215 42" X 15" Wye GFY4218 42" X 18" Wye GFY4804 48" X 4" Wye GFY4806 48" X 6" Wye GFY4808 48" X 8" Wye GFY4810 48" X 10" Wye GFY4812 48" X 12" Wye GFY4815 48" X 15" Wye GFY4818 48" X 18" Wye GFY4824 48" X 24" Wye GFY6004 60" X 4" Wye GFY6006 60" X 6" Wye GFY6008 60" X 8" Wye GFY6010 60" X 10" Wye GFY6012 60" X 12" Wye GFY6015 60" X 15" Wye GFY6018 60" X 18" Wye GFY6024 60" X 24" Wye 10" 12" 15" 18" 24" 30" 36" SADDLE TEES Size Number GFST1004 10" TO 4" GFST1006 10" TO 6" GFST1008 10" TO 8" GFST1204 12" TO 4" GFST1206 12" TO 6" GFST1208 12" TO 8 " GFST1210 12" TO 10" GFST1504 15" X 4" GFST1506 15" X 6" GFST1508 15" X 8" GFST1510 15" X 10" GFST1512 15" X 12" GFST1804 18" X 4" GFST1806 18" X 6" GFST1808 18" X 8" GFST1810 18" X 10" GFST1812 18" X 12" GFST1815 18" X 15" GFST2404 24" X 4" GFST2406 24" X 6" GFST2408 24" X 8" GFST2410 24" X 10" GFST2412 24" X 12" GFST3004 30" X 4" GFST3006 30" X 6" GFST3008 30" X 8" GFST3010 30" X 10" GFST3012 30" X 12" GFST3604 36" X 4" GFST3606 36" X 6" GFST3608 36" X 8 " GFST3610 36" X 10" GFST3612 36" X 12" 6" 8" 10" 12" 15" 18" 24" Size Number GFT0604 6" TO 4" Tee GFT0804 8" TO 4" Tee GFT0806 8" TO 6" Tee GFT1004 10" TO 4" Tee GFT1006 10" TO 6" Tee GFT1008 10" TO 8" Tee GFT1204 12" TO 4" Tee GFT1206 12" TO 6" Tee GFT1208 12" TO 8" Tee GFT1210 12" TO 10" Tee GFT1504 15" TO 4" Tee GFT1506 15" TO 6" Tee GFT1508 15" TO 8" Tee GFT1510 15" TO 10" Tee GFT1512 15" TO 12" Tee GFT1804 18" TO 4" Tee GFT1806 18" TO 6" Tee GFT1808 18" TO 8" Tee GFT1810 18" TO 10" Tee GFT1812 18" TO 12" Tee GFT1815 18" TO 15" Tee GFT2404 24" TO 4" Tee GFT2406 24" TO 6" Tee GFT2408 24" TO 8" Tee GFT2410 24" TO 10" Tee GFT2412 24" TO 12" Tee Size Number GFT2415 24" TO 15" Tee GFT2418 24" TO 18" Tee GFT3004 30" TO 4" Tee GFT3006 30" TO 6" Tee GFT3008 30" TO 8" Tee GFT3010 30’’ TO 10" Tee GFT3012 30’’ TO 12" Tee GFT3015 30’’ TO 15" Tee GFT3018 30’’ TO 18" Tee GFT3024 30’’ TO 24" Tee GFT3604 36’’ TO 4" Tee GFT3606 36’’ TO 6" Tee GFT3608 36’’ TO 8" Tee GFT3610 36’’ TO 10" Tee GFT3612 36’’ TO 12" Tee GFT3615 36’’ TO 15" Tee GFT3618 36’’ TO 18" Tee GFT3624 36’’ TO 24" Tee GFT3630 36" TO 30" Tee GFT4206 42" TO 6" Tee GFT4208 42" TO 8" Tee GFT4210 42" TO 10" Tee GFT4212 42" TO 12" Tee GFT4215 42" TO 15" Tee GFT4218 42" TO 18" Tee GFT4224 42" TO 24" Tee 24" 30" 36" 42" Size Number GFT4230 42" TO 30" Tee GFT4236 42" TO 36" Tee GFT4804 48" TO 4" Tee GFT4806 48" TO 6" Tee GFT4808 48" TO 8" Tee GFT4810 48" TO 10" Tee GFT4812 48" TO 12" Tee GFT4815 48" TO 15" Tee GFT4818 48" TO 18" Tee GFT4824 48" TO 24" Tee GFT4830 48" TO 30" Tee GFT4836 48" TO 36" Tee GFT4842 48" T0 42" Tee GFT6004 60" TO 4" Tee GFT6006 60" TO 6" Tee GFT6008 60" TO 8" Tee GFT6010 60" TO 10" Tee GFT6012 60" TO 12" Tee GFT6015 60" TO 15" Tee GFT6018 60" TO 18" Tee GFT6024 60" TO 24" Tee GFT6030 60" TO 30" Tee GFT6036 60" TO 36" Tee GFT6042 60" TO 42" Tee GFT6048 60" TO 48" Tee 42" 48" 60" PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS Harco pvc_drain_basin_detail_sheet PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 2019-001 HARCO DEBRIS BAG DETAIL Layout1 PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. CONTACT JAIME BAHR PROJECT EXTRA SPACE LOCATION EXTRA SPACE - - AGENCY START DATE BOOK DATE 08/30/2021 PREPARED BY ALEX DENNIS TABLE OF CONTENTS 8in CL350 Ductile Iron Tyton-Joint Pipe CML with Gasket DI C153 8in MJ 45 Bend MJ Restraints with Accessories DI Pipe - Star FIRE HYDRANT DI C153 8x6in MJxFLG Tee 6in Mueller A-2362-19 E381 MJxFLG RW Gate Valve OL NDZ Stem 316 BN 6X48 DI 6-Hole PO Hydrant Bury CL with Gasket 6X24 DI 6-Hole Hydrant Extension Solid Without Groove CL ITP 6H Hydrant Break-Off Bolt & Nut Set A307 Zinc Plated Silicone Filled ITP Non-Asbestos NSF61 Ring Gasket 16th Inch Thick Clow LBI 400A 6 Break-Off Check Valve 6-Hole Low Lead STORM DRAIN WT PIPE Prinsco Goldflo HDPE Fittings Harco pvc_drain_basin_detail_sheet 2019-001 HARCO DEBRIS BAG DETAIL Layout1 PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 8in CL350 Ductile Iron Tyton-Joint Pipe CML with Gasket PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Smooth Running Jobs Ductile Iron Pipe ANSI/AWWA STANDARDS: PRESSURE CLASS 350 TYTON-JOINT® PIPE ANSI/AWWA C151/A21.5, Ductile Iron Pipe, Centrifugally Cast for Water. Ductile Iron Tyton Joint Pipe is centrifugally cast in metal molds in accordance with ANSI/ AWWA C151/A21.5. The asphaltic outside coating is in accordance with ANSI/AWWA C151/A21.51. ANSI/AWWA C111/A21.11 Standard for Rubber-Gasket Joints for Ductile Iron Pressure Pipe.The standard rubber compound is SBR – Styrene Butadiene Rubber. This material has a maximum service temperature rating of 150°F and is used as the predominant gasket material for Drinking Water, Sea Water, Sanitary Sewer, Reclaimed Water, Raw Water, & Storm Water. ANSI/AWWA C104/A21.4, Cement-Mortar Lining for Ductile-Iron Pipe and Fittings for Water. The cement-mortar lining and inside coating are in accordance with ANSI/AWWA C104/ A21.4. Special linings and/or coatings can be furnished for specific conditions. ANSI/AWWA C111/A21.11, Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings. Tyton Gaskets are furnished in accordance with ANSI/AWWA C111/A21.11. ANSI/AWWA C105/A21.5, Polyethylene Encasement for Ductile Iron Pipe Systems. If specifiers and users believe that corrosive soils will be encountered where our products are to be installed, please refer to ANSI/ AWWA C105/A21.5, for proper external protection procedures. ASTM A536 "Standard Specification for Ductile Iron Castings." Tyton joint pipe is NSF/ANSI 61 Certified for drinking water system components. MADE IN U.S.A. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS DI C153 8in MJ 45 Bend PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. IMPORT DUCTILE IRON MJ COMPACT FITTINGS ANSI/AWWA C153/A21.53 Ductile Iron per ASTM A536. *Flanged fittings rated at 250 psi. Mechanical joints 2” – 24” rated at 350 psi and 30” – 48” at 250 psi. *Note: With rubber annular ring flange gasket, 2” – 24” Flanged fittings can be rated at 350 psi. In accordance with ANSI/AWWA C153/A21.53 and UL Requirement. In accordance with ANSI/AWWA C153/A21.53. Fittings not listed in ANSI/AWWA have dimensions per as noted in Catalog. Do not include Accessories, Cement Lining and Coatings. Flanged ends on Fittings match ANSI/AWWA C115/A21.15 and ANSI B16.1 CLASS 125 Flanges. In accordance with ANSI/AWWA C104/A21.4. Asphaltic Seal Coat inside and out in accordance with ANSI/AWWA C104/A21.4 ANSI/AWWA C111/ A21.11. Compounded for water and sewer, NSF 61 Certified. Low Alloy Steel in accordance with ANSI/AWWA C111/A21.11. 3”- 24” Underwriters Laboratories Listed and UL/NSF 61. MATERIAL : PRESSURE : TESTING : LAYING LENGTH : GENERAL SPECIFICATIONS Smooth Running Jobs WEIGHTS : FLANGES : CEMENT LINING : COATING : GASKETS : T-BOLTS/NUTS : APPROVALS : PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS MJ Restraints with Accessories DI Pipe - Star PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. RESTRAINTS Stargrip® Mechanical Joint Wedge Action Restraint for DI Pipe Smooth Running Jobs Visit: www.starpipeproducts.com for more information Product Features • Gland is made from high strength Ductile Iron per ASTM A536, Grade 65-45-12 and is compatible with all Mechanical Joints conforming to ANSI/AWWA C111/A21.11. •A standard MJ gasket is used with this fitting. Meets ANSI/AWWA C111/A21.11 for gasket specs. •3/4” UNC T-bolts, heavy hex nuts, high strength, low alloy steel per AWWA C111. • The Wedge Assembly is designed with a Break-Off Torque Control Head, ensuring proper installation. • The Stargrip® offers a full 5° deflection through 12" size, 3° on 14"-24", 2° on 30"-36" and 1° on 42"-48". • Minimum safety factor of 2:1 • Stargrip® sizes 3"-36" are listed with Underwriters Laboratories Inc. and sizes 3"-12" are approved by Factory Mutual Research. • The Wedges are heat treated to a minimum of 370 BHN. • The Wedge Assembly is designed to fit specific pipe sizes. • Stargrip® eliminates tie rods and thrust blocks. • Standard gland color is Black. • Stargrip® may also be used on steel pipe* up to 12" (*transition gasket required on 12" and under). For 14" and larger steel applications, contact Star Pipe. STARGRIP for DUCTILE IRON PIPE ACCESSORY PACK (Stargrip, Gasket, Bolts and Nuts) FIRE HYDRANT PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS DI C153 8x6in MJxFLG Tee PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. IMPORT DUCTILE IRON MJ COMPACT FITTINGS ANSI/AWWA C153/A21.53 Ductile Iron per ASTM A536. *Flanged fittings rated at 250 psi. Mechanical joints 2” – 24” rated at 350 psi and 30” – 48” at 250 psi. *Note: With rubber annular ring flange gasket, 2” – 24” Flanged fittings can be rated at 350 psi. In accordance with ANSI/AWWA C153/A21.53 and UL Requirement. In accordance with ANSI/AWWA C153/A21.53. Fittings not listed in ANSI/AWWA have dimensions per as noted in Catalog. Do not include Accessories, Cement Lining and Coatings. Flanged ends on Fittings match ANSI/AWWA C115/A21.15 and ANSI B16.1 CLASS 125 Flanges. In accordance with ANSI/AWWA C104/A21.4. Asphaltic Seal Coat inside and out in accordance with ANSI/AWWA C104/A21.4 ANSI/AWWA C111/ A21.11. Compounded for water and sewer, NSF 61 Certified. Low Alloy Steel in accordance with ANSI/AWWA C111/A21.11. 3”- 24” Underwriters Laboratories Listed and UL/NSF 61. MATERIAL : PRESSURE : TESTING : LAYING LENGTH : GENERAL SPECIFICATIONS Smooth Running Jobs WEIGHTS : FLANGES : CEMENT LINING : COATING : GASKETS : T-BOLTS/NUTS : APPROVALS : PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6in Mueller A-2362-19 E381 MJxFLG RW Gate Valve OL NDZ Stem 316 BN PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. GATE VALVES 3"-12" A-2362 RW GATE VALVES MJ X FLG This information is based on the best data available at the date printed above. Please check with www.muellercompany.com for any updates or changes. 6" MJ x FLG RW GATE VALVE OPEN LEFT NDZ STEM T316 SS HARDWARE Smooth Running Jobs SPECIFICATIONS: Meets or exceeds all applicable requirements of ANSI/AWWA C509 and C515, UL Listed, FM Approved, and certified to ANSI/NSF 61 & 372. Standard Mechanical Joint ends comply with ANSI/AWWA C111 Flanged Ends (2” thru 12”) with flange drilling complying to ANSI B16.1 Class 125 Ductile Iron body with nominal 10 mils MUELLER® Pro-Gard® Fusion Epoxy Coated interior and exterior surfaces Epoxy coating meets or exceeds all applicable requirements of ANSI/AWWA C550 Standard and is certified to ANSI/NSF Standard 61 Ductile Iron wedge, symmetrical & fully encapsulated with molded *EPDM Rubber; no exposed iron Stem non-rising (NRS) Manganese **Bronze, ASTM B138 Alloy C67600 Triple O-ring seal stuffing box (2 upper & 1 lower O-rings) with fourth o-ring serving as dirt seal *EPDM Rubber 2" square wrench nut-open left *Bolts & Nuts for stuffing box and bonnet Type 316 Stainless Steel 350 psig (2400 kPa/24 barg) maximum working pressure, 700 psig (4800 kPa/48 barg) static test pressure UL Listed, FM Approved: 350 psig (2400 kPa/24 barg) Mueller valves are designed for potable water application **Bronze components meet current lead-free requirements A-2362-19 *E381 MANUFACTURED IN THE U.S.A. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6X48 DI 6-Hole PO Hydrant Bury CL with Gasket PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Part Number Description Size POB648-6 D.I. 6-Hole PO Hydrant Bury C/L with Gasket 6" x 48" Smooth Running Jobs Fire Hydrant Burys & Extension Spools Short Form Specification: Casting : As per ANSI/AWWA C153/A21.53Material : Ductile Iron per ASTM A536Cement Lining : As per ANSI/AWWA C104/A21.4, 1/8" thickness minimum Coating : Standard NSF-61 approved asphaltic coating inside-out Pressure Rating : 350 PSI hydrostatic pressure PUSH-ON HYDRANT BURYS Quality Manufacturers Since 1960 SIP Industries PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6X24 DI 6-Hole Hydrant Extension Solid Without Groove CL PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Part Number Description Size HE-624-6S D.I. 6-Hole Hydrant Extension Solid Without Groove C/L 6" x 24" Smooth Running Jobs Fire Hydrant Burys & Extension Spools Short Form Specification: HYDRANT SOLID EXTENSIONS 1.All Radii and Fillets to be 0.12 unless otherwise specified 2.PART NO letter size 0.31" high and 0.13" Raised 3.HEAT CODE and INDIA letter size 0.25" high and 0.13" Raised 4.Manufactured in accordance with AWWA Standard C-110 5.Extensions are Cement Lining in accordance with AWWA standard C-104 6.Meets ANSI/AWWA C110/A21.10 Specification 7.Cement Lined & Tar Coated per ANSI/AWWA C104/A21.4 8.Meets 250 PSI Water Working Pressure (CLASS 250) Quality Manufacturers Since 1960 SIP Industries PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS ITP 6H Hydrant Break-Off Bolt & Nut Set A307 Zinc Plated Silicone Filled PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. BOLTS & NUTS Smooth Running Jobs HEX HYDRANT BREAK-OFF BOLTS A307 GRADE A SUBMITTAL SPECIFICATIONS Abstract of ASTM A307 Grade A Grade: Low Carbon Steel 60,000 PSI **NOTE: These bolts have been altered to allow for shearing at the joint on impact. CHEMICAL REQUIREMENTS Chemical analysis shall be performed in accordance with ASTM A751 CARBON MAX MANGANESE MAX PHOPHOROUS MAX SULFER MAX 0.29 0.90 0.04 0.15 MECHANICAL REQUIREMENTS *Prior to drilling HARDNESS BRINEL MIN MAX HARDNESS ROCKWELL MIN MAX TENSILE STRENGTH (KSI) MIN MAX ELONGATION IN 2 IN (50MM) MIN 121 241 69 100 60 - 18 Hex Nuts ASTM A563 (ASME B18.2.2) Heavy hex Nuts ASTM A563 (ASME B18.2.2) Washers ASTM F844-90 FINISH Plain Zinc Plated Hot Dip Galvanized Cad Plated DIMENSIONAL DATA: Unless otherwise specified, threads shall be the coarse threaded series as specified in the latest issue of ANSI / ASME B1.1, page A-26. Class 2A tolerance. Grade A Bolts shall have Hex Bolt Dimensions as given in the latest issue of ANSI / ASME B 18.2.1 page C1. Unless otherwise specified Grade A Bolts should be used with Hex Nuts. ADDITIONAL INFORMATION: Additional information can be found in ASTM A307 DTD 2001, ASTM A563, DTD 2001 ADDITIONAL INFORMATION: Break Off Bolts have a drilled hole in the shank. Dimensions are 11/32 Hole for 5/8 Bolts; 13/32 for 3/4 Bolt. Hole Depth is 2 3/8”. OTHER: BOLTS ARE FILLED WITH SILICONE. BREAK-OFF BOLTS HAVE A HOLE DRILLED IN THE SHANK WITH THE DIMENSIONS OF 11/32 INCH (FOR 5/8” BOLTS) AND 13/32 INCH (FOR ¾” BOLTS) AND 2 3/8 INCHES DEEP. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS ITP Non-Asbestos NSF61 Ring Gasket 16th Inch Thick PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. FLANGE GASKETS TEADIT NA 1082SAN NSF61 APPROVED NON ASBESTOS GASKET Smooth Running Jobs SUBMITTAL SPECIFICATIONS GASKETS MEET THE PRESSURE RATINGS, DRILLING AND DIMENSIONS OF ANSI/ASME B16.21 AND AWWA C111 NSF 61 CERTIFIED FOR CHLORINATED POTABLE WATER TECHNICAL DATA MANUFACTURES STYLE COLOR BINDER TEMP MAX HARDNESS SHORE A TENSILE STRENGTH ASTM F- 152 ELONGATION APPLICATION CERTIFICATION MATERIAL Teadit. NA1082SAN Blue Proprietary 752 N/A 1885 N/A Potable Water Systems NSF 61 Non Asbestos Full Face Ring 1/16” 1/8” GENERAL DESCRIPTION: Teadit style NA1002SAN is specifically formulated to pass criteria established in NSF-61 for sealing materials, as well as providing excellent resistance to conductivity. ** Domestically manufactured in the USA** PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS Clow LBI 400A 6 Break-Off Check Valve 6-Hole Low Lead PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Refer to www.clowvalve.com for more information Part Number Description Size LBI 400A Break-Off Check Valve 6-Hole Low Lead 6" Smooth Running Jobs Clow LBI 400A Break-Off Check Valve The Clow LBI 400A is an efficient means for preventing the loss of water when a hydrant has been knocked off its mounting. A double-groove extension riser controls the break point enabling the bury to be protected during impact. As the break occurs, upward movement of a secured threaded stainless steel rod automatically releases a spring-loaded bronze valve flapper into the waterway. In static operation the valve flapper is housed in a recessed area out of the waterway.ea The Clow LBI 400A can easily be installed with any wet barrel fire hydrant regardless of model or manufacturer. Any bolt-hole pattern may be ordered upon request. All Clow LBI 400A are made standard with protective fusion epoxy lining. Conservation sensitive areas will also recognize the opportunity to reduce water losses by specifying the Clow LBI 400A . A hydrant broken from a 6” line under normal operating pressures can quickly result in large and highly visible water losses as indicated by the flow table below. TYPICAL FLOW RATES FOR A 6” LINE STORM DRAIN PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS WT PIPE PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Page 1 of 2 1717 16th St NE | Willmar, MN 56201 | 800.992.1725 | www.prinsco.com © Prinsco, Inc. 01/18 GOLDFLO WT® DUAL WALL SPECIFICATION Scope This specification designates the requirements for 4- through 60- inch I.D. Prinsco GOLDFLO WT® pipe for use in gravity-flow drainage applications. Pipe Requirements Prinsco GOLDFLO WT pipe shall have annular exterior corrugations with a smooth interior allowing for a Manning’s “n” design value of 0.012 and shall meet the following standards:  4- though 10- inch shall meet AASHTO M252, Type S  12- through 60- inch shall meet ASTM F2306 or AASHTO M294, Type S Materials GOLDFLO WT pipe and fabricated fittings shall be manufactured using High Density Polyethylene (HDPE) meeting the minimum requirements of cell classification of 424420C for 4- through 10- inch diameters and 435400C for 12- through 60- inch diameters, as defined and described in ASTM D3350 except the carbon black content shall be 2 – 4%. The HDPE pipe material for 12- through 60- inch diameters shall be tested for slow crack growth resistance using the notched constant ligament-stress (NCLS) test as specified in sections 9.4 and 5.1 of AASHTO M294 and ASTM F2306, respectively. Average failure time of the five test specimens shall not be less than 24 hours. Joint Performance GOLDFLO WT pipe shall be joined using watertight bell and spigot type joints meeting AASHTO M252, M294 or ASTM F2306. The integral joints shall be watertight according to ASTM D3212. Gaskets shall meet the requirements of ASTM F477 and shall be installed by the manufacturer. An approved joint lubricant, available from the manufacturer, shall be applied to the bell and gasket during installation. GOLDFLO WT joints shall be assembled in accordance with the manufacturer’s requirements to ensure installed watertight performance. Fittings Fittings shall meet the requirements of AASHTO M252, M294 or ASTM F2306. Standard fittings are available as listed on Prinsco’s website www.prinsco.com and custom fittings may be fabricated to customer specific requirements. Physical Pipe Dimensions Nominal ID (in) Approximate OD (in) Length (ft) Corrugation Pitch (in) Approximate Weight/foot (lb) Min. Pipe Stiffness @ 5% Deflection (psi) 4” 4.8 20 .67 0.5 50 6” 7.1 20 .80 1.0 50 8” 9.5 20 1.00 1.7 50 10” 11.9 20 1.30 2.3 50 12” 14.4 10, 20 2.00 3.1 50 15” 17.6 10, 20 2.67 4.5 42 18” 21.5 11, 20 3.00 6.5 40 24” 28.2 11, 20 4.00 11.0 34 30” 34.7 11, 20 4.00 14.6 29 36” 40.6 11, 20 4.70/ 3.90* 19.0 22.5 42” 47.5 11, 20 6.00 25 21 48” 54.1 11, 20 6.00 30 20 60” 66.8 12, 20 5.90 40 15 *Contact your Prinsco sales representative to determine actual corrugation pitch. Page 2 of 2 1717 16th St NE | Willmar, MN 56201 | 800.992.1725 | www.prinsco.com © Prinsco, Inc. 01/18 GOLDFLO WT® DUAL WALL SPECIFICATION Installation Pipe and fittings shall be installed in accordance with ASTM D2321 and Prinsco’s published installation guidelines. Minimum cover heights for AASHTO H-25 loads shall be 12” for 4- through 48-inch diameter pipe and 18” for 60-inch pipe. The minimum cover shall be measured from the top of the pipe to the bottom of flexible pavement or to the top of rigid pavement. Contact your local Prinsco representative or visit www.prinsco.com for the latest installation guidelines. Reference Specifications This specification references the latest edition and revisions of the following standard specifications:  AASHTO M294 – Standard Specification for Corrugated Polyethylene Pipe, 300- to 1500-mm (12- to 60-in.) Diameter  AASHTO M 252 – Standard Specification for Corrugated Polyethylene Drainage Pipe  ASTM F2306 – Standard Specification for 12 to 60-in. (300 to 1500 mm) Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings for Gravity-Flow Storm Sewer and Subsurface Drainage Applications  ASTM D3350 – Standard Specification for Polyethylene Plastics Pipe and Fittings Materials  ASTM D477 – Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe  ASTM D3212 – Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals  ASTM D2321 – Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications  ASTM F2487 – Standard Practice for Underground Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene Pipelines PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS Prinsco Goldflo HDPE Fittings PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. ACCESSORIES: GOLDFLO WT®| GOLDFLO®| ECOFLO WT®20 GASkET FOR SNAP COUPLER Size Number 4" GFGSK04 6" GFGSK06 8" GFGSK08 10" GFGSK10 SOIL TIGhT SPLIT COUPLER Size Number 4" SC04 6" SC06 8" SC08 10" SC10 12" SC12 15" SC15H 18" SC18 24" SC24 30" SC30 36" SC36 ELBOW - 45° Size Number 4" GFE0445 6" GFE0645 8" GFE0845 10" GFE1045 12" GFE1245 15" GFE1545 18" GFE1845 24" GFE2445 30" GFE3045 36" GFE3645 42" GFE4245 48" GFE4845 60" GFE6045 ELBOW - 90° (3-Piece) Size Number 4" GFE0490 6" GFE0690 8" GFE0890 10" GFE1090 12" GFE1290 15" GFE1590 18" GFE1890 24" GFE2490 30" GFE3090 36" GFE3690 42" GFE4290 48" GFE4890 60" GFE6090 ELBOW - 90° (2-Piece) Size Number 4" GFE04902 6" GFE06902 8" GFE08902 10" GFE10902 12" GFE12902 15" GFE15902 18" GFE18902 24" GFE24902 30" GFE30902 36" GFE36902 42" GFE42902 48" GFE48902 60" GFE60902 ELBOW - 22.5° Size Number 4" GFE0422 6" GFE0622 8" GFE0822 10" GFE1022 12" GFE1222 15" GFE1522 18" GFE1822 24" GFE2422 30" GFE3022 36" GFE3622 42" GFE4222 48" GFE4822 60" GFE6022 mARmAC COUPLER Size Number 4" MM4 6" MM6 8" MM8 10" MM10 12" MM12 15" MM15 18" MM18 24" MM24 30" MM30 36" MM36 42" MM42 48" MM48 60" MM60 ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® NEW! GOLDLOKTM couplers from Prinsco! SOILTIGhT GOLDLOkTm COUPLER 24" GFSTS24 30" GFSTS30 36" GFSTS36 42" GFSTS42 48" GFSTS48 WATERTIGhT GOLDLOkTm COUPLER 24" GFWTS24 30" GFWTS30 36" GFWTS36 42" GFWTS42 48" GFWTS48 ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® 800.992.1725 | www.prinsco.com ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® 800.992.1725 | www.prinsco.com CROSS TEE Size Number 4" GFCT04 6" GFTC06 8" GFTC08 10" GFTC10 12" GFCT12 15" GFCT15 18" GFCT18 24" GFCT24 30" GFTC30 TEE Size Number 4" GFT0404 6" GFT0606 8" GFT0808 10" GFT1010 12" GFT1212 15" GFT1515 18" GFT1818 24" GFT2424 30" GFT3030 36" GFT3636 42" GFT4242 48" GFT4848 60" GFT6060 21 PRINSCO DUAL-WALL CATCh BASINS Made to project specifications, maximum height up to 8'. Size Number Unit 12" GFCB12 Each 15" GFCB15 Each 18" GFCB18 Each 24" GFCB24 Each 30" GFCB30 Each 36" GFCB36 Each 42" GFCB42 Each 48" GFCB48 Each 60" GFCB60 Each REDUCER (One-Step) Size Reducer 6" Avail. in 4" 8" Avail. in 4"-6" 10" Avail. in 4"-8" 12" Avail. in 4"-10" 15" Avail. in 4"-12" 18" Avail. in 4"-15" 24" Avail. in 4"-18" 30" Avail. 4"- 24" 36" Avail. 4"-30" 42" Avail. 10"-36" 48" Avail. 10"-42" 60" Avail. 10"-48" WYE - 45° Size Number 4" GFY0404 6" GFY0606 8" GFY0808 10" GFY1010 12" GFY1212 15" GFY1515 18" GFY1818 24" GFY2424 30" GFY3030 ACCESSORIES: GOLDFLO WT®| GOLDFLO®| ECOFLO WT®See next page. 22 REDUCING TEESACCESSORIES: GOLDFLO WT®| GOLDFLO®| ECOFLO WT®ACCESSORIES GOLDFLO WT ®| GOLDFLO ®| ECOFLO WT ® 800.992.1725 | www.prinsco.com REDUCING WYES 6" 8" 10" 12" 15" 18" 24" 30" Size Number GFY0604 6" X 4" Wye GFY0804 8" X 4" Wye GFY0806 8" X 6" Wye GFY1004 10" X 4" Wye GFY1006 10" X 6" Wye GFY1008 10" X 8" Wye GFY1204 12" TO 4" Wye GFY1206 12" TO 6" Wye GFY1208 12" TO 8" Wye GFY1210 12" TO 10" Wye GFY1504 15" X 4" Wye GFY1506 15" X 6" Wye GFY1508 15" X 8" Wye GFY1510 15" X 10" Wye GFY1512 15" X 12" Wye GFY1804 18" X 4" Wye GFY1806 18" X 6" Wye GFY1808 18" X 8" Wye GFY1810 18" X 10" Wye GFY1812 18" X 12" Wye GFY1815 18" X 15" Wye GFY2404 24" X 4" Wye GFY2406 24" X 6" Wye GFY2408 24" X 8" Wye GFY2410 24" X 10" Wye GFY2412 24" X 12" Wye GFY2415 24" X 15" Wye GFY2418 24" X 18" Wye GFY3004 30" X 4" Wye GFY3006 30" X 6" Wye GFY3008 30" X 8" Wye GFY3010 30" X 10" Wye GFY3012 30" X 12" Wye GFY3015 30" X 15" Wye GFY3018 30" X 18" Wye 36" 42" 48" 60" Size Number GFY3604 36" X 4" Wye GFY3606 36" X 6" Wye GFY3608 36" X 8" Wye GFY3610 36" X 10" Wye GFY3612 36" X 12" Wye GFY3615 36" X 15" Wye GFY3618 36" X 18" Wye GFY3624 36" X 24" Wye GFY4204 42" X 4" Wye GFY4206 42" X 6" Wye GFY4208 42" X 8" Wye GFY4210 42" X 10" Wye GFY4212 42" X 12" Wye GFY4215 42" X 15" Wye GFY4218 42" X 18" Wye GFY4804 48" X 4" Wye GFY4806 48" X 6" Wye GFY4808 48" X 8" Wye GFY4810 48" X 10" Wye GFY4812 48" X 12" Wye GFY4815 48" X 15" Wye GFY4818 48" X 18" Wye GFY4824 48" X 24" Wye GFY6004 60" X 4" Wye GFY6006 60" X 6" Wye GFY6008 60" X 8" Wye GFY6010 60" X 10" Wye GFY6012 60" X 12" Wye GFY6015 60" X 15" Wye GFY6018 60" X 18" Wye GFY6024 60" X 24" Wye 10" 12" 15" 18" 24" 30" 36" SADDLE TEES Size Number GFST1004 10" TO 4" GFST1006 10" TO 6" GFST1008 10" TO 8" GFST1204 12" TO 4" GFST1206 12" TO 6" GFST1208 12" TO 8 " GFST1210 12" TO 10" GFST1504 15" X 4" GFST1506 15" X 6" GFST1508 15" X 8" GFST1510 15" X 10" GFST1512 15" X 12" GFST1804 18" X 4" GFST1806 18" X 6" GFST1808 18" X 8" GFST1810 18" X 10" GFST1812 18" X 12" GFST1815 18" X 15" GFST2404 24" X 4" GFST2406 24" X 6" GFST2408 24" X 8" GFST2410 24" X 10" GFST2412 24" X 12" GFST3004 30" X 4" GFST3006 30" X 6" GFST3008 30" X 8" GFST3010 30" X 10" GFST3012 30" X 12" GFST3604 36" X 4" GFST3606 36" X 6" GFST3608 36" X 8 " GFST3610 36" X 10" GFST3612 36" X 12" 6" 8" 10" 12" 15" 18" 24" Size Number GFT0604 6" TO 4" Tee GFT0804 8" TO 4" Tee GFT0806 8" TO 6" Tee GFT1004 10" TO 4" Tee GFT1006 10" TO 6" Tee GFT1008 10" TO 8" Tee GFT1204 12" TO 4" Tee GFT1206 12" TO 6" Tee GFT1208 12" TO 8" Tee GFT1210 12" TO 10" Tee GFT1504 15" TO 4" Tee GFT1506 15" TO 6" Tee GFT1508 15" TO 8" Tee GFT1510 15" TO 10" Tee GFT1512 15" TO 12" Tee GFT1804 18" TO 4" Tee GFT1806 18" TO 6" Tee GFT1808 18" TO 8" Tee GFT1810 18" TO 10" Tee GFT1812 18" TO 12" Tee GFT1815 18" TO 15" Tee GFT2404 24" TO 4" Tee GFT2406 24" TO 6" Tee GFT2408 24" TO 8" Tee GFT2410 24" TO 10" Tee GFT2412 24" TO 12" Tee Size Number GFT2415 24" TO 15" Tee GFT2418 24" TO 18" Tee GFT3004 30" TO 4" Tee GFT3006 30" TO 6" Tee GFT3008 30" TO 8" Tee GFT3010 30’’ TO 10" Tee GFT3012 30’’ TO 12" Tee GFT3015 30’’ TO 15" Tee GFT3018 30’’ TO 18" Tee GFT3024 30’’ TO 24" Tee GFT3604 36’’ TO 4" Tee GFT3606 36’’ TO 6" Tee GFT3608 36’’ TO 8" Tee GFT3610 36’’ TO 10" Tee GFT3612 36’’ TO 12" Tee GFT3615 36’’ TO 15" Tee GFT3618 36’’ TO 18" Tee GFT3624 36’’ TO 24" Tee GFT3630 36" TO 30" Tee GFT4206 42" TO 6" Tee GFT4208 42" TO 8" Tee GFT4210 42" TO 10" Tee GFT4212 42" TO 12" Tee GFT4215 42" TO 15" Tee GFT4218 42" TO 18" Tee GFT4224 42" TO 24" Tee 24" 30" 36" 42" Size Number GFT4230 42" TO 30" Tee GFT4236 42" TO 36" Tee GFT4804 48" TO 4" Tee GFT4806 48" TO 6" Tee GFT4808 48" TO 8" Tee GFT4810 48" TO 10" Tee GFT4812 48" TO 12" Tee GFT4815 48" TO 15" Tee GFT4818 48" TO 18" Tee GFT4824 48" TO 24" Tee GFT4830 48" TO 30" Tee GFT4836 48" TO 36" Tee GFT4842 48" T0 42" Tee GFT6004 60" TO 4" Tee GFT6006 60" TO 6" Tee GFT6008 60" TO 8" Tee GFT6010 60" TO 10" Tee GFT6012 60" TO 12" Tee GFT6015 60" TO 15" Tee GFT6018 60" TO 18" Tee GFT6024 60" TO 24" Tee GFT6030 60" TO 30" Tee GFT6036 60" TO 36" Tee GFT6042 60" TO 42" Tee GFT6048 60" TO 48" Tee 42" 48" 60" PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS Harco pvc_drain_basin_detail_sheet PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 2019-001 HARCO DEBRIS BAG DETAIL Layout1 PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org September 27, 2021 La Tierra Consulting 555 West 5th Street 35th Floor Los Angeles, CA 90013 Inland Valley Pipeline, INC 33020 Howard Road Menifee, CA 92584 Re: Private Fire Main Plan Review – EXTRA SPACE STORAGE 79120 CORPORATE CENTER DR, LA QUINTA, CA 92253 The private fire main plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections and tests must be observed: 1) Pre-Pour Thrust Block cutout inspection 2) Rough Piping / Hydrostatic Test a. Confirm pipe material, bury depth and backfill requirements b. Minimum 200 psi for two (2) hours or at 50 psi in excess of the maximum static pressure when it is in excess of 150 psi. 3) Underground Flush & Final - a. Flush of the underground supply line until clear of all debris and to the satisfaction of the inspector. b. The underground flush shall be done through a pipe or hose equal in size to the sprinkler underground supply pipe, prior to connection to the above ground sprinkler piping. c. Appropriate valve and connection signage is provided d. Private fire hydrants are painted red and provided with OSFM tag. e. Provide the completed Contractor’s Material and Test Certificate for Underground Pipe The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79120 CORPORATE CENTER DRIVE PERMIT#: FNCUW2021-0002 DATE ISSUED: 9/27/2021 DESCRIPTION: EXTRASPACE STORAGE FIRE MAIN CONTRACTOR: INLAND VALLEY PIPELINE, INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.