Loading...
FNCUW2021-0004ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT JAMES A SHIRLEY CONSTRUCTION INC 59160 MESA DRIVE YUCCA VALLEY CA 92284137 3 (760)228-0447 OFFICE@JASHIRLEYINC. COM BILL TO JAMES A. SHIRLEY CONSTRUCTION, INC P.O. BOX 555 WEWOKA OK 74884 (760)228-0447 BILLING@JASHIRLEYIN C.COM CONTRACTOR JAMES A SHIRLEY CONSTRUCTION INC 59160 Mesa Dr.Yucca Valley CA 92284137 3 (760)228-0447 greg@jashirleyinc.com OWNER SUNRISE LQ, LLC 300 EAGLE DANCE CIR PALM DESERT CA 92211 (760)228-0447 CONDITIONS Description: TM 37790 LOT 42 SALES AND DESIGN CENTER/ PRIVATE FIRE LINE Type: FIRE NEW COMMERCIAL UNDERGROUND WATER (WEB) Subtype: Status: FINALED Applied: 10/27/2021 ECON Parcel No: 764200071 Site Address: 59140 MARBELLA LA QUINTA,CA 92253 Approved: 11/6/2021 KHET Subdivision: TR 37790 Block: Lot: 42 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/23/2022 KHET Valuation: $10,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Friday, February 24, 2023 2:25:22 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FNCUW2021-0004 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES THRUST BLOCK PRE-POUR KHET 1/4/2022 1/4/2022 APPROVED UG HYDRO KHET 1/5/2022 1/5/2022 APPROVED UG ROUGH PIPING KHET 1/5/2022 1/5/2022 APPROVED NEED TO CHECK TORQUE FLUSH KHET 1/5/2022 1/5/2022 APPROVED FIRE FINAL**KHET 1/5/2022 1/5/2022 NOT READY SEE NOTES *No Fees for reinspection (1) Need FDC and Address Signage. (2) Caps for FDC (3) Completed and signed Contractor's Material and Test Certificate. (Now Provided - See Attachments) DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE NEW COMMERCIAL - UNDERGROUND WATER 101-0000-42421 0 $500.00 $500.00 11/10/21 WEB9845 633538257 97 CREDIT 710357 ECON FIRE NEW COMMERCIAL - UNDERGROUND WATER PC 101-0000-42420 0 $417.00 $417.00 11/10/21 WEB9845 633538257 97 CREDIT 710357 ECON Total Paid for FIRE FEES: $917.00 $917.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 11/10/21 WEB9845 633538257 97 CREDIT 710357 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 11/10/21 WEB9845 633538257 97 CREDIT 710357 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$933.00 $933.00 Printed: Friday, February 24, 2023 2:25:22 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FNCUW2021-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/27/2021 Etrakit Contractor 1ST SUBMITTAL PLAN 21-0689 ANDALUSIA SALES and DESIGN FIRE SERVICE.pdf 1 DOC 11/6/2021 KOHL HETRICK FNCUW2021-0004 - APPROVED PLANS.pdf FNCUW2021-0004 - APPROVED PLANS.pdf 1 DOC 11/6/2021 KOHL HETRICK FNCUW2021-0004 - COA AND JOB CARD.pdf FNCUW2021-0004 - COA AND JOB CARD.pdf 1 DOC 1/10/2022 KOHL HETRICK FNCUW2021-0004 - CONTRACTOR CERT - SIGNED.pdf FNCUW2021-0004 - CONTRACTOR CERT - SIGNED.pdf 1 BOND INFORMATION FIRE FINAL**LIN 3/8/2022 3/8/2022 NOT READY FIRE FINAL**KHET 3/23/2022 3/23/2022 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 10/27/2021 10/28/2021 10/27/2021 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 10/27/2021 11/10/2021 11/6/2021 APPROVED SEE ATTACHMENTS PARENT PROJECTS Printed: Friday, February 24, 2023 2:25:22 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FNCUW2021-0004 ++VANACCESSIBLE ROUTEHCHCHC EXISTING PARKING LOT 40 SPACES TOTAL(3) EXISTING ACCESSIBLE SPACES(1) VAN ACCESSIBLE 24A1.411111NOTE: PATH IS A GENERALCIRCULATION PATH ALLOWEDBY 11B-206.2.1 EXCEPTION 3FOR GENERAL MAINTENANCEAND EQUIPMENT MONITORING(FIRE RISER CLOSET) 11-203.524" MIN24" MIN7 -0"60 X 60 PAD12A1.0A15'-0"RECESSED ENTRYRECESSEDENTRYACCESSIBLE ROUTE4 -0 4 -0 7'-0 "LIMIT OF EXISTING SIDEWALKNEW SIDEWALK9'-0" 9'-0" 9'-0"5'-0"8 -0"4'-0"18'-0"EXISTING ACCESSIBLEPARKING, RESTRIPE PERATTACHED DIAGRAM, TYPICALEXISTING ACCESSIBLE SIGN TO REMAIN, TYP.LOT 42LOT 41LOT 40LOT 39LOT 43LOT 44EXISTING CURB20'-0"20'-0"20'-0"40'-0"19'-5"START PTFOR FOUNDATION12'-6 15/32"23'-8"60'-0"60'-0"59'-2"4'-0"4'-0"8'-0"FS 441.50EXISTINGFS 442.36FS 442.68FS 443.50FS 443.50442.38FFE 443.50FFE 443.50FFE 443.50FS 443.50FFE 443.502.3%2.3%2.3%1.0%3.5%3.5%4" C-900 CL-305 DR 14 UGD57'-0 48'-10½72'-0½46'-10½15'-957'-3110'-0½28'-5½4970sfSTATE APPROVEDCOMMERCIALMODULARMARBELLAEX. 8" PVC CVWD MAIN4" GATE VALVEAMES C500 4" BACKFLOW W/ FDCHYDRANTEX.(POINT OF FLOW TEST)(POINT OF CONNECTION 6"-12" ABOVE SLAB)4" FIRE RISERN12342-WAY FDC 4x2½x2½ w/ BRASS FACE PLATE4" WAFER CHECK VALVE4" D.I.EL: -194" AMES C500 RPDA4" C-900 PVCTO BLDG.4" D.I.PER NFPA (2 IN.)NFPA 24 & WT-014" C-900 PVCFROM CITY12" MIN TAMPER DEVICES ON CONTROL VALVES CONSTANTLY MONITOREDCLEARANCE THRUST BLOCKS PER434" PVC C9004" STAINLESS STEELFROM ON-SITE U.G.4" STAINLESS STEELPOINT OF CONNECTION AT 6" FROM FINISHED FLOOR8" PVC CVWD MAIN2" ANNULAR CLEARANCETO BUILDINGEXTERIOR6'X6' AMES STAINLESS STEEL IN-BUILDING RISER 4" GROOVE X CAST IRON PIPE SIZE4" PVC C900THRUST BLOCKS PER NFPA 2436" MINFIRE HYDRANTTHRUST BLOCK (BY OTHERS)LEGENDVICINITY MAPFLOW TESTUNDERGROUND PIPING GENERAL NOTESFIRE SERVICE PLANSCALE: 1" = 20' 0"THE RECIPIENT OF THESE PLANS HEREBY ACKNOWLEDGES THAT ALL PLANS, DETAILS, SPECIFICATIONS AND/OR METHODS OF INSTALLATION CONTAINED IN THIS SET OF DRAWINGS IS THE SOLE PROPERTY OF SYMONS FIRE PROTECTION, INC., AND THAT ANY USE OF THIS SET OF DRAWINGS IS PROHIBITED AND IS A VIOLATION OF COPYRIGHT LAWS WITHOUT FIRST RECEIVING PERMISSION FROM SYMONSDATE-REVISIONSAS NOTEDMARKPHONE-MARBELLA LOT 42 & 43LA QUINTA, CACONTRACT WITH:FS1AUTHORITY HAVING JURISDICTIONDESCRIPTIONDRAWN BY: DEREK POWELLSCALE :PROJECT:ANDALUSIA SALES AND DESIGN CENTER(760) 564-2122-SHEET-21-0689JOBDATEDRAWING TITLE:LA QUINTA FIRE DEPARTMENT10-13-2021FIRE SERVICEBYSUNRISE LQ, LLCN1.Installation shall conform to N.F.P.A. 24 (2016 EDITION.) and the City Of LaQuinta regulations.2.Minimum depth of bury for underground piping to be 2'-6" in pedestrianareas. All piping under traffic areas to have a minimum bury of 3'-0" measuredfrom top of pipe.3.All underground piping, fittings, valves & equipment to be UL listed or FMapproved. Piping from 5'-0" outside the building foot print to be PVC C900.Piping within 5'-0" of building foot print to be Ames in-building riser.4.Excavation to proper depth for installation and backfill with native soils.compaction to 90% M.P.M. unless noted otherwise.5.Underground system to be flushed and hydrostatically tested at 200 psi or50 psi higher than the maximum system pressure for 2 hours per N.F.P.A. 24(10.10.2.2.1) before connection to sprinkler system. By installing contractor.6.Contractors material & test certification to be delivered upon inspection byinstalling contractor 7.Dimensions are approximate. Field verify all dimensions, and coordinate allinstallation with other trades and utilities.8.Thrust blocking shall be required at all changes of direction, restraining pipeadapters listed as a restraining adapter can be utilized in lieu of thrust blocks. 9.Pipe shall be installed with sand surrounding the pipe zone. see trenchdetails.10.All ferrous pipe and fittings below grade to be wrapped and coated. perN.F.P.A. 24 10.1.611.All fitting on PVC to be M.J. fittings with ductile iron gland, gasket, t-boltsand nuts or equal. Fittings attached to valves and transitions between PVC& ferrous piping are to be flange with mechanical joint adapters. 12.Underground piping to be C900 DR14 PVC. Exposed piping to be DuctileIron 52 pipe 13.All penetrations through slabs for in building feeding fire sprinkler risersshall require 2" annular clearance around the pipe. By installing contractor.14.Chain and lock and a tamper switch to be provided on backflow devicesby installing contractor at the time of installation. 15.Piping must be 1'-0" min. below the footing per NFPA 24(A.10.4.3.1.2)16. All required traffic control to be provided by installing contractor as wellas any traffic control plans.17.Point of connection and wet tap shown for reference only see additionaldetailed on civiL plan18.Fire sprinkler point of connection shall be 6"-12" max above slab.19.All onsite water and sewer facilities shown on this drawing are privateand shall be designed to meet requirements of the California uniformplumbing code and shall be reviewed as part of the building permit plancheckPRIVATE FIRE LINE CONTRACTORPRIVATE FIRE LINE CONTRACTORN.T.S.N.T.S.Cp=0.7APPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:FIRE SAFETY SPECIALIST11/06/2021 6:04:31 AMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.PERMIT # -FNCUW2021-0004Kohl HetrickReason: I am approving this documentContact Info: 760-409-5109 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org November 6, 2021 James A Shirley Construction Inc. 59160 Mesa Drive Yucca Valley, CA 92284 Re: Private Fire Main Plan Review – ANDALUSIA SALES CENTER FNCUW2021-0004 / 59140 MARBELLA, LA QUINTA, CA 92253 The private fire main plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections and tests must be observed: 1) Pre-Pour Thrust Block cutout inspection 2) Rough Piping / Hydrostatic Test a. Confirm pipe material, bury depth and backfill requirements b. Minimum 200 psi for two (2) hours or at 50 psi in excess of the maximum static pressure when it is in excess of 150 psi. 3) Underground Flush & Final - a. Flush of the underground supply line until clear of all debris and to the satisfaction of the inspector. b. The underground flush shall be done through a pipe or hose equal in size to the sprinkler underground supply pipe, prior to connection to the above ground sprinkler piping. c. Appropriate valve and connection signage is provided d. Private fire hydrants are painted red and provided with OSFM tag. e. Provide the completed Contractor’s Material and Test Certificate for Underground Pipe The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: PERMIT#: DATE ISSUED: DESCRIPTION: CONTRACTOR: HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.