Loading...
FNCUW2022-0001ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT JUDY LEE 555 WEST 5TH STREET, 35TH FLOOR LOS ANGELES CA 90013 (909)721-1636 JUDY@LATIERRACONS ULTING.COM BILL TO Judy Lee 2549 Eastbluff Drive, Unit 384 Newport Beach CA 92660 (909)721-1636 judy@latierraconsultin g.com CONTRACTOR NEAR-CAL CORP 512 CHANEY STREET LAKE ELSINORE CA 92530 (909)721-1636 davida@nearcal.com OWNER EXTRA SPACE PROP 126 PO BOX 800729 DALLAS TX 75380 (909)721-1636 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 3/1/2022 3/1/2022 REQUESTED HYDRAUILIC CALCS AND SPECS. CONDITIONS Description: Underground service for RV carport. Type: FIRE NEW COMMERCIAL UNDERGROUND WATER (WEB) Subtype: Status: FINALED Applied: 2/24/2022 EPRS Parcel No: 600390011 Site Address: 79120 CORPORATE CENTER DR LA QUINTA,CA 92253 Approved: 3/2/2022 KHET Subdivision: PM 29351 Block: Lot: 1 Issued: 3/2/2022 JLIM Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/2/2022 KHET Valuation: $125,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: See related permit BCOM2021-0103. FINANCIAL INFORMATION Printed: Friday, March 03, 2023 3:49:53 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FNCUW2022-0001 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES THRUST BLOCK PRE-POUR KHET 4/27/2022 4/27/2022 APPROVED UG HYDRO KHET 5/2/2022 5/2/2022 APPROVED UG ROUGH PIPING KHET 5/2/2022 5/2/2022 APPROVED FLUSH KHET 5/2/2022 5/2/2022 APPROVED FIRE FINAL**KHET 5/2/2022 5/2/2022 APPROVED REVIEWS RETURNED PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE NEW COMMERCIAL - UNDERGROUND WATER 101-0000-42421 0 $334.00 $334.00 3/2/22 WEB10892 635729544 08 CREDIT JUDY LEE EPRS FIRE NEW COMMERCIAL - UNDERGROUND WATER PC 101-0000-42420 0 $167.00 $167.00 3/2/22 WEB10892 635729544 08 CREDIT JUDY LEE EPRS Total Paid for FIRE FEES: $501.00 $501.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 3/2/22 WEB10892 635729544 08 CREDIT JUDY LEE EPRS Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 3/2/22 WEB10892 635729544 08 CREDIT JUDY LEE EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$517.00 $517.00 Printed: Friday, March 03, 2023 3:49:53 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FNCUW2022-0001 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 2/24/2022 Etrakit Public Registration 1st SUBMITTAL - UNDERGOUND SERVICE PLANS 2022-01-22 - Utility Plan v1.pdf 1 DOC 3/2/2022 KOHL HETRICK 1ST SUBMITTAL - ALL CUT SHEETS_1.pdf 1ST SUBMITTAL - ALL CUT SHEETS_1.pdf 1 DOC 3/2/2022 KOHL HETRICK FNCUW2022-0001 - APPROVED PLANS.pdf FNCUW2022-0001 - APPROVED PLANS_1.pdf 1 DOC 3/2/2022 KOHL HETRICK FNCUW2022-0001 - COA AND JOB CARD.pdf FNCUW2022-0001 - COA AND JOB CARD.pdf 1 BOND INFORMATION REVIEW TYPE REVIEWER SENT DATE DUE DATE DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 2/24/2022 2/25/2022 3/1/2022 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 2/24/2022 3/10/2022 3/2/2022 APPROVED SEE ATTACHMENTS Printed: Friday, March 03, 2023 3:49:53 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FNCUW2022-0001 La Quinta Office of the Fire MarshalFire Safety Specialist Kohl Hetrick - 760-777-7074 / kohl.hetrick@fire.ca.gov STRAND ENGINEERING, INC.1001 Avenida Pico, Ste. C-121, San Clemente, CA 92673 (949) 431-0610C:\Users\stran\OneDrive\Projects\1012 Extra Space 1561 La Quinta\Engineering\ConDocs\Sheet-Files\1012-DT.dwg, DETAILS, Aug 16, 2021 4:29pm, stranKnow what'sbelow.before you dig.CallREXTRA SPACE STORAGE2795 EAST COTTONWOOD PARKWAYSUITE 400SALT LAKE CITY, UT 84121CONC. VALLEY GUTTER4" MIN 12" MIN 34" CRUSHED, WASHEDROCK.BACKFILL ZONE SHALLBE COMPACTED TO AMINIMUM 90%COMPACTION.NON-WOVENGEOTEXTILE FABRIC,OVERLAP 12"24" PERFORATEDHDPE3'6" P.C.C.4" CLASS II A.B. COMPACTED TO95% RELATIVE DENSITYSCARIFY 12" AND COMPACT TO90% RELATIVE DENSITY2-#4 BARS1" TO 3'1.5'BVALLEY GUTTERN.T.S.3" AC4" CLASS II A.B. COMPACTED TOMIN. 95% RELATIVE DENSITY12" COMPACTED SUBGRADE TOMIN. 90% RELATIVE DENSITYCAC PAVEMENT SECTIONN.T.S.AREM TR14CR(32) FILTER W/ MEDIAN.T.S.FDRYWELLN.T.S.DINFILTRATION TRENCHN.T.S.4" DOWNSPOUT PER ARCHITECTURAL6" PVC DRAINCONNECT TO STORMDRAIN1% MIN90° ELBOWEDOWNSPOUT CONNECTIONN.T.S.12" DIA PERFORATED PVC PIPE3/4" CRUSHED WASHED ROCK30"24"8"X12" PVC REDUCERPCC COLLAR, 560-C-3250BINGHAM & TAYLORCLEANOUT BOX NO. 76218" PVC PIPE6"PVC COND DRAINLINE FROM BUILDINGSEE PLANS FOR SIZELINE DRYWELL W/ MIRIFI 140N24"DETAILSFINISH SURFACE45° BENDNOTES:1.CHIMNEY SIZE AND CONNECTIONS SHALLBE 8".2.PIPE AND FITTINGS SHALL BE PVC3.BEDDING AND BACKFILL SHALL BE THESAME AS FOR STORM DRAIN MAIN.PROPOSED STORM DRAINVARIES VARIES 45° WYEGSTORM DRAIN CLEAN OUTN.T.S.BINGHAM & TAYLORCLEANOUT BOX NO. 7621PCC COLLAR, 560-C-32508" PVC PIPEA A SECTION A-APLAN24" MIN 12" MIN42" MINPCC, 560-C-3200JTHRUST BLOCKSN.T.S.UNDISTURBED SOILSHORING AND BRACING OF TRENCH IS THERESPONSIBILITY OF THE CONTRACTOR ANDSHALL BE IN COMPLIANCE WITH ALLAPPLICABLE CALIFORNIA SAFETY LAWSAC PAVEMENT SEEDETAIL THIS SHEET12" COMPACTED SUBGRADE TOMIN. 90% RELATIVE DENSITYFILL SAND OR PEAGRAVEL3' MINNOTE:TRENCH BACKFILL SHALL MEET REQUIREMENTS OF NFPA 24: 10.9.1 AS AMENDED BY CA FIRE CODE.BACKFILL SHALL BE WELL TAMPED IN LAYERS OR PUDDLE UNDER AND AROUND PIPES TO PREVENTSETTLEMENT OR LATERAL MOVEMENT. BACKFILL SHALL CONSIST OF CLEAN FILL SAND OR PEA GRAVELTO A MINIMUM 6" BELOW AND TO A MINIMUM 12" ABOVE PIPE AND SHALL CONTAIN NO ASHES,CINDERS, REFUSE, ORGANIC MATTER, OR OTHER CORROSIVE MATERIALS. OTHER BACKFILL MATERIALSAND METHODS ARE PERMITTED WHERE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER ANDAPPROVED BY THE ENFORCING AGENCY.HTRENCH DETAILN.T.S.PAINT WITH TWO COATS FIRE ENGINE REDTWO 3" BANDS OF REFLECTIVE WHITE TAPEKBOLLARDN.T.S.PCC, 560-C-320012"30" 6"THRUST BLOCK, SEE DETAILTHIS SHEETCLOW 860 HYDRANTCLOW LP619 BREAK-OFFCHECK VALVECHRISTY G8 TRAFFIC VALVE BOX.CAST IRON COVER & RIMINSCRIBED "FIRE"6" GATE VALVE WITHFLANGE & R.T. FITTINGSTHRUST BLOCK, SEE DETAILTHIS SHEET6" POLY WRAPPED DIP11"8"PCC, 560-C-3200TYPE C BLUE REFLT. MARKERCEMENT W/ HOTMELT BITUMEN ADHESIVEIFIRE HYDRANTN.T.S.TEE W/ 6" FLANGE & R.T.FITTINGS12" PVC SDR35 RISERLFIRE RISERN.T.S.SYSTEM RISERSEE FIRE SPRINKLERPLANS FOR DETAILS4" DIP CLASS 150POLY WRAPPEDJOINT RESTRAINTPAVEMENTDIP FLANGE AND SPIGOTPIECE, POLY WRAPBELOW GRADEFOOTINGCALCULATIONS:SANDY SILT (3,000 PSI)WORKING PRESSURE 150 PSI, SF 1.5MIN HORIZONTAL BEARING AREA FOR 8" MAIN (90°) 6.8 SFPER THRUST BLOCK SPREADSHEET10' MINIMUM12"6"2-BOLLARDS PERDETAIL K THISSHEET3' MIN Near-Cal Corp. 512 Chaney Street Lake Elsinore, California 92530 P: (951) 245-5400 Project: 2108 ESS LA QUINTA - 1561 46600 ADAMS ST LA QUINTA, California 92253     Submittal #6.0 - ESS LA QUINTA - 6-02500-0 UNDER GROUND UTILITIES SUBMITTAL   Revision 0 Submittal Manager Marilyn Jarvis (Near-Cal Corp.) Status Open Date Created Sep 8, 2021 Issue Date Sep 8, 2021 Spec Section Responsible Contractor INLAND VALLEY PIPELINE, INC.Received From JAIME BAHR (INLAND VALLEY PIPELINE, INC.) Received Date Sep 8, 2021 Submit By Sep 9, 2021 Final Due Date Sep 23, 2021 Lead Time Cost Code Location Type Product Information Approvers Marilyn Jarvis (Near-Cal Corp.), JEFF GOODMAN (JAMES GOODMAN ARCHITECTURE) Ball in Court JEFF GOODMAN (JAMES GOODMAN ARCHITECTURE) Distribution Kevin Tait (Near-Cal Corp.), Rick Rodriguez (NEAR-CAL CORP), JAMES GOODMAN (JAMES GOODMAN ARCHITECTURE), MARK GLASMIRE (EXTRA SPACE STORAGE) Description     Submittal Workflow Name Sent Date Due Date Returned Date Response Attachments General Information Attachments      EXTRA SPACE SUBS.pdf  JAIME BAHR Sep 8, 2021 Sep 9, 2021 Sep 8, 2021 Submitted EXTRA SPACE SUBS.pdf   Marilyn Jarvis Sep 8, 2021 Sep 16, 2021 Sep 8, 2021 Approved EXTRA SPACE SUBS.pdf (Current)  JEFF GOODMAN Sep 8, 2021 Sep 23, 2021  Pending     Near-Cal Corp.Page 1 of 1 Printed On: Sep 9, 2021 09:49 AM PDT    CONTACT JAIME BAHR PROJECT EXTRA SPACE LOCATION EXTRA SPACE - - AGENCY START DATE BOOK DATE 08/30/2021 PREPARED BY ALEX DENNIS TABLE OF CONTENTS 8in CL350 Ductile Iron Tyton-Joint Pipe CML with Gasket DI C153 8in MJ 45 Bend MJ Restraints with Accessories DI Pipe - Star FIRE HYDRANT DI C153 8x6in MJxFLG Tee 6in Mueller A-2362-19 E381 MJxFLG RW Gate Valve OL NDZ Stem 316 BN 6X48 DI 6-Hole PO Hydrant Bury CL with Gasket 6X24 DI 6-Hole Hydrant Extension Solid Without Groove CL ITP 6H Hydrant Break-Off Bolt & Nut Set A307 Zinc Plated Silicone Filled ITP Non-Asbestos NSF61 Ring Gasket 16th Inch Thick Clow LBI 400A 6 Break-Off Check Valve 6-Hole Low Lead STORM DRAIN WT PIPE Prinsco Goldflo HDPE Fittings Harco pvc_drain_basin_detail_sheet 2019-001 HARCO DEBRIS BAG DETAIL Layout1 PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 8in CL350 Ductile Iron Tyton-Joint Pipe CML with Gasket PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Smooth Running Jobs Ductile Iron Pipe ANSI/AWWA STANDARDS: PRESSURE CLASS 350 TYTON-JOINT® PIPE ANSI/AWWA C151/A21.5, Ductile Iron Pipe, Centrifugally Cast for Water. Ductile Iron Tyton Joint Pipe is centrifugally cast in metal molds in accordance with ANSI/ AWWA C151/A21.5. The asphaltic outside coating is in accordance with ANSI/AWWA C151/A21.51. ANSI/AWWA C111/A21.11 Standard for Rubber-Gasket Joints for Ductile Iron Pressure Pipe.The standard rubber compound is SBR – Styrene Butadiene Rubber. This material has a maximum service temperature rating of 150°F and is used as the predominant gasket material for Drinking Water, Sea Water, Sanitary Sewer, Reclaimed Water, Raw Water, & Storm Water. ANSI/AWWA C104/A21.4, Cement-Mortar Lining for Ductile-Iron Pipe and Fittings for Water. The cement-mortar lining and inside coating are in accordance with ANSI/AWWA C104/ A21.4. Special linings and/or coatings can be furnished for specific conditions. ANSI/AWWA C111/A21.11, Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings. Tyton Gaskets are furnished in accordance with ANSI/AWWA C111/A21.11. ANSI/AWWA C105/A21.5, Polyethylene Encasement for Ductile Iron Pipe Systems. If specifiers and users believe that corrosive soils will be encountered where our products are to be installed, please refer to ANSI/ AWWA C105/A21.5, for proper external protection procedures. ASTM A536 "Standard Specification for Ductile Iron Castings." Tyton joint pipe is NSF/ANSI 61 Certified for drinking water system components. MADE IN U.S.A. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS DI C153 8in MJ 45 Bend PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. IMPORT DUCTILE IRON MJ COMPACT FITTINGS ANSI/AWWA C153/A21.53 Ductile Iron per ASTM A536. *Flanged fittings rated at 250 psi. Mechanical joints 2” – 24” rated at 350 psi and 30” – 48” at 250 psi. *Note: With rubber annular ring flange gasket, 2” – 24” Flanged fittings can be rated at 350 psi. In accordance with ANSI/AWWA C153/A21.53 and UL Requirement. In accordance with ANSI/AWWA C153/A21.53. Fittings not listed in ANSI/AWWA have dimensions per as noted in Catalog. Do not include Accessories, Cement Lining and Coatings. Flanged ends on Fittings match ANSI/AWWA C115/A21.15 and ANSI B16.1 CLASS 125 Flanges. In accordance with ANSI/AWWA C104/A21.4. Asphaltic Seal Coat inside and out in accordance with ANSI/AWWA C104/A21.4 ANSI/AWWA C111/ A21.11. Compounded for water and sewer, NSF 61 Certified. Low Alloy Steel in accordance with ANSI/AWWA C111/A21.11. 3”- 24” Underwriters Laboratories Listed and UL/NSF 61. MATERIAL : PRESSURE : TESTING : LAYING LENGTH : GENERAL SPECIFICATIONS Smooth Running Jobs WEIGHTS : FLANGES : CEMENT LINING : COATING : GASKETS : T-BOLTS/NUTS : APPROVALS : PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS MJ Restraints with Accessories DI Pipe - Star PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. RESTRAINTS Stargrip® Mechanical Joint Wedge Action Restraint for DI Pipe Smooth Running Jobs Visit: www.starpipeproducts.com for more information Product Features • Gland is made from high strength Ductile Iron per ASTM A536, Grade 65-45-12 and is compatible with all Mechanical Joints conforming to ANSI/AWWA C111/A21.11. •A standard MJ gasket is used with this fitting. Meets ANSI/AWWA C111/A21.11 for gasket specs. •3/4” UNC T-bolts, heavy hex nuts, high strength, low alloy steel per AWWA C111. • The Wedge Assembly is designed with a Break-Off Torque Control Head, ensuring proper installation. • The Stargrip® offers a full 5° deflection through 12" size, 3° on 14"-24", 2° on 30"-36" and 1° on 42"-48". • Minimum safety factor of 2:1 • Stargrip® sizes 3"-36" are listed with Underwriters Laboratories Inc. and sizes 3"-12" are approved by Factory Mutual Research. • The Wedges are heat treated to a minimum of 370 BHN. • The Wedge Assembly is designed to fit specific pipe sizes. • Stargrip® eliminates tie rods and thrust blocks. • Standard gland color is Black. • Stargrip® may also be used on steel pipe* up to 12" (*transition gasket required on 12" and under). For 14" and larger steel applications, contact Star Pipe. STARGRIP for DUCTILE IRON PIPE ACCESSORY PACK (Stargrip, Gasket, Bolts and Nuts) FIRE HYDRANT PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS DI C153 8x6in MJxFLG Tee PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. IMPORT DUCTILE IRON MJ COMPACT FITTINGS ANSI/AWWA C153/A21.53 Ductile Iron per ASTM A536. *Flanged fittings rated at 250 psi. Mechanical joints 2” – 24” rated at 350 psi and 30” – 48” at 250 psi. *Note: With rubber annular ring flange gasket, 2” – 24” Flanged fittings can be rated at 350 psi. In accordance with ANSI/AWWA C153/A21.53 and UL Requirement. In accordance with ANSI/AWWA C153/A21.53. Fittings not listed in ANSI/AWWA have dimensions per as noted in Catalog. Do not include Accessories, Cement Lining and Coatings. Flanged ends on Fittings match ANSI/AWWA C115/A21.15 and ANSI B16.1 CLASS 125 Flanges. In accordance with ANSI/AWWA C104/A21.4. Asphaltic Seal Coat inside and out in accordance with ANSI/AWWA C104/A21.4 ANSI/AWWA C111/ A21.11. Compounded for water and sewer, NSF 61 Certified. Low Alloy Steel in accordance with ANSI/AWWA C111/A21.11. 3”- 24” Underwriters Laboratories Listed and UL/NSF 61. MATERIAL : PRESSURE : TESTING : LAYING LENGTH : GENERAL SPECIFICATIONS Smooth Running Jobs WEIGHTS : FLANGES : CEMENT LINING : COATING : GASKETS : T-BOLTS/NUTS : APPROVALS : PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6in Mueller A-2362-19 E381 MJxFLG RW Gate Valve OL NDZ Stem 316 BN PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. GATE VALVES 3"-12" A-2362 RW GATE VALVES MJ X FLG This information is based on the best data available at the date printed above. Please check with www.muellercompany.com for any updates or changes. 6" MJ x FLG RW GATE VALVE OPEN LEFT NDZ STEM T316 SS HARDWARE Smooth Running Jobs SPECIFICATIONS: Meets or exceeds all applicable requirements of ANSI/AWWA C509 and C515, UL Listed, FM Approved, and certified to ANSI/NSF 61 & 372. Standard Mechanical Joint ends comply with ANSI/AWWA C111 Flanged Ends (2” thru 12”) with flange drilling complying to ANSI B16.1 Class 125 Ductile Iron body with nominal 10 mils MUELLER® Pro-Gard® Fusion Epoxy Coated interior and exterior surfaces Epoxy coating meets or exceeds all applicable requirements of ANSI/AWWA C550 Standard and is certified to ANSI/NSF Standard 61 Ductile Iron wedge, symmetrical & fully encapsulated with molded *EPDM Rubber; no exposed iron Stem non-rising (NRS) Manganese **Bronze, ASTM B138 Alloy C67600 Triple O-ring seal stuffing box (2 upper & 1 lower O-rings) with fourth o-ring serving as dirt seal *EPDM Rubber 2" square wrench nut-open left *Bolts & Nuts for stuffing box and bonnet Type 316 Stainless Steel 350 psig (2400 kPa/24 barg) maximum working pressure, 700 psig (4800 kPa/48 barg) static test pressure UL Listed, FM Approved: 350 psig (2400 kPa/24 barg) Mueller valves are designed for potable water application **Bronze components meet current lead-free requirements A-2362-19 *E381 MANUFACTURED IN THE U.S.A. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6X48 DI 6-Hole PO Hydrant Bury CL with Gasket PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Part Number Description Size POB648-6 D.I. 6-Hole PO Hydrant Bury C/L with Gasket 6" x 48" Smooth Running Jobs Fire Hydrant Burys & Extension Spools Short Form Specification: Casting : As per ANSI/AWWA C153/A21.53Material : Ductile Iron per ASTM A536Cement Lining : As per ANSI/AWWA C104/A21.4, 1/8" thickness minimum Coating : Standard NSF-61 approved asphaltic coating inside-out Pressure Rating : 350 PSI hydrostatic pressure PUSH-ON HYDRANT BURYS Quality Manufacturers Since 1960 SIP Industries PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS 6X24 DI 6-Hole Hydrant Extension Solid Without Groove CL PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Part Number Description Size HE-624-6S D.I. 6-Hole Hydrant Extension Solid Without Groove C/L 6" x 24" Smooth Running Jobs Fire Hydrant Burys & Extension Spools Short Form Specification: HYDRANT SOLID EXTENSIONS 1.All Radii and Fillets to be 0.12 unless otherwise specified 2.PART NO letter size 0.31" high and 0.13" Raised 3.HEAT CODE and INDIA letter size 0.25" high and 0.13" Raised 4.Manufactured in accordance with AWWA Standard C-110 5.Extensions are Cement Lining in accordance with AWWA standard C-104 6.Meets ANSI/AWWA C110/A21.10 Specification 7.Cement Lined & Tar Coated per ANSI/AWWA C104/A21.4 8.Meets 250 PSI Water Working Pressure (CLASS 250) Quality Manufacturers Since 1960 SIP Industries PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS ITP 6H Hydrant Break-Off Bolt & Nut Set A307 Zinc Plated Silicone Filled PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. BOLTS & NUTS Smooth Running Jobs HEX HYDRANT BREAK-OFF BOLTS A307 GRADE A SUBMITTAL SPECIFICATIONS Abstract of ASTM A307 Grade A Grade: Low Carbon Steel 60,000 PSI **NOTE: These bolts have been altered to allow for shearing at the joint on impact. CHEMICAL REQUIREMENTS Chemical analysis shall be performed in accordance with ASTM A751 CARBON MAX MANGANESE MAX PHOPHOROUS MAX SULFER MAX 0.29 0.90 0.04 0.15 MECHANICAL REQUIREMENTS *Prior to drilling HARDNESS BRINEL MIN MAX HARDNESS ROCKWELL MIN MAX TENSILE STRENGTH (KSI) MIN MAX ELONGATION IN 2 IN (50MM) MIN 121 241 69 100 60 - 18 Hex Nuts ASTM A563 (ASME B18.2.2) Heavy hex Nuts ASTM A563 (ASME B18.2.2) Washers ASTM F844-90 FINISH Plain Zinc Plated Hot Dip Galvanized Cad Plated DIMENSIONAL DATA: Unless otherwise specified, threads shall be the coarse threaded series as specified in the latest issue of ANSI / ASME B1.1, page A-26. Class 2A tolerance. Grade A Bolts shall have Hex Bolt Dimensions as given in the latest issue of ANSI / ASME B 18.2.1 page C1. Unless otherwise specified Grade A Bolts should be used with Hex Nuts. ADDITIONAL INFORMATION: Additional information can be found in ASTM A307 DTD 2001, ASTM A563, DTD 2001 ADDITIONAL INFORMATION: Break Off Bolts have a drilled hole in the shank. Dimensions are 11/32 Hole for 5/8 Bolts; 13/32 for 3/4 Bolt. Hole Depth is 2 3/8”. OTHER: BOLTS ARE FILLED WITH SILICONE. BREAK-OFF BOLTS HAVE A HOLE DRILLED IN THE SHANK WITH THE DIMENSIONS OF 11/32 INCH (FOR 5/8” BOLTS) AND 13/32 INCH (FOR ¾” BOLTS) AND 2 3/8 INCHES DEEP. PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS ITP Non-Asbestos NSF61 Ring Gasket 16th Inch Thick PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. FLANGE GASKETS TEADIT NA 1082SAN NSF61 APPROVED NON ASBESTOS GASKET Smooth Running Jobs SUBMITTAL SPECIFICATIONS GASKETS MEET THE PRESSURE RATINGS, DRILLING AND DIMENSIONS OF ANSI/ASME B16.21 AND AWWA C111 NSF 61 CERTIFIED FOR CHLORINATED POTABLE WATER TECHNICAL DATA MANUFACTURES STYLE COLOR BINDER TEMP MAX HARDNESS SHORE A TENSILE STRENGTH ASTM F- 152 ELONGATION APPLICATION CERTIFICATION MATERIAL Teadit. NA1082SAN Blue Proprietary 752 N/A 1885 N/A Potable Water Systems NSF 61 Non Asbestos Full Face Ring 1/16” 1/8” GENERAL DESCRIPTION: Teadit style NA1002SAN is specifically formulated to pass criteria established in NSF-61 for sealing materials, as well as providing excellent resistance to conductivity. ** Domestically manufactured in the USA** PHONE (909) 597-7000 FAX (909) 597-7050 SUBMITTAL DATA MATERIALS Clow LBI 400A 6 Break-Off Check Valve 6-Hole Low Lead PROJECT EXTRA SPACE AGENCY SPEC SECTION COMMENT PREPARED BY WESTERN WATER WORKS SUPPLY CO. Refer to www.clowvalve.com for more information Part Number Description Size LBI 400A Break-Off Check Valve 6-Hole Low Lead 6" Smooth Running Jobs Clow LBI 400A Break-Off Check Valve The Clow LBI 400A is an efficient means for preventing the loss of water when a hydrant has been knocked off its mounting. A double-groove extension riser controls the break point enabling the bury to be protected during impact. As the break occurs, upward movement of a secured threaded stainless steel rod automatically releases a spring-loaded bronze valve flapper into the waterway. In static operation the valve flapper is housed in a recessed area out of the waterway.ea The Clow LBI 400A can easily be installed with any wet barrel fire hydrant regardless of model or manufacturer. Any bolt-hole pattern may be ordered upon request. All Clow LBI 400A are made standard with protective fusion epoxy lining. Conservation sensitive areas will also recognize the opportunity to reduce water losses by specifying the Clow LBI 400A . A hydrant broken from a 6” line under normal operating pressures can quickly result in large and highly visible water losses as indicated by the flow table below. TYPICAL FLOW RATES FOR A 6” LINE OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org March 2, 2022 Inland Valley Pipeline, INC 33020 Howard Road Menifee, CA 92584 Re: Private Fire Main Plan Review – EXTRA SPACE STORAGE – RV CANOPY – SPK UG FNCUW2022-0001 / 79120 CORPORATE CENTER DRIVE, LA QUINTA, CA 92253 The private fire main plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections and tests must be observed: 1) Pre-Pour Thrust Block cutout inspection 2) Rough Piping / Hydrostatic Test a. Confirm pipe material, bury depth and backfill requirements b. Minimum 200 psi for two (2) hours or at 50 psi in excess of the maximum static pressure when it is in excess of 150 psi. 3) Underground Flush & Final - a. Flush of the underground supply line until clear of all debris and to the satisfaction of the inspector. b. The underground flush shall be done through a pipe or hose equal in size to the sprinkler underground supply pipe, prior to connection to the above ground sprinkler piping. c. Appropriate valve and connection signage is provided d. Private fire hydrants are painted red and provided with OSFM tag. e. Provide the completed Contractor’s Material and Test Certificate for Underground Pipe The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79120 CORPORATE CENTER DRIVE PERMIT#: FNCUW2022-0001 DATE ISSUED: 3/2/2022 DESCRIPTION: RV CANOPY – SPRK UNDEGROUND MAIN CONTRACTOR: INLAND VALLEY PIPELINE INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.