Loading...
FS2021-0001ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT DESERT FIRE EXTINGUISHER CO INC PO BOX 1607 PALM SPRINGS CA 92263 (760)322-0995 MARK@DESERT- FIRE.COM CONTRACTOR DESERT FIRE EXTINGUISHER CO INC PO BOX 1607 PALM SPRINGS CA 92263 (760)322-0995 MARK@DESERT- FIRE.COM OWNER WASHINGTON ADAM PARTNERSHIP 42620 CAROLINE CT 102 PALM DESERT CA 92253 (760)322-0995 CONDITIONS Description: TIFFANY'S SWEET SPOT / ANSUL HOOD SYSTEM Type: FIRE SUPRESSION (WEB)Subtype: HOOD & DUCT Status: FINALED Applied: 1/21/2021 ECON Parcel No: 604050037 Site Address: 78590 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 2/4/2021 KHET Subdivision: Block: Lot: Issued: 4/1/2021 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 4/7/2021 KHET Valuation: $4,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Friday, February 24, 2023 3:14:03 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FS2021-0001 BOND INFORMATION INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FIRE FINAL**KHET 4/7/2021 4/7/2021 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 1/21/2021 2/4/2021 2/4/2021 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) ARMANDO MAGALLON 1/21/2021 1/22/2021 2/24/2021 COMPLETE PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE COMMERCIAL COOKING HOOD AND DUCT SYSTEMS 101-0000-42421 0 $161.00 $161.00 4/1/21 WEB7796 075424 CREDIT DESERT FIRE EXTINGUISHER CO INC ECON FIRE COMMERCIAL COOKING HOOD AND DUCT SYSTEMS PC 101-0000-42420 0 $242.00 $242.00 4/1/21 WEB7796 075424 CREDIT DESERT FIRE EXTINGUISHER CO INC ECON Total Paid for FIRE FEES: $403.00 $403.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 4/1/21 WEB7796 075424 CREDIT DESERT FIRE EXTINGUISHER CO INC ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 4/1/21 WEB7796 075424 CREDIT DESERT FIRE EXTINGUISHER CO INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$418.00 $418.00 Printed: Friday, February 24, 2023 3:14:03 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FS2021-0001 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 1/21/2021 EtrakitContractor 1ST SUBMITTAL - CUT SHEETS Cut sheets.pdf 1 DOC 1/21/2021 EtrakitContractor APPLICATION Fire App.pdf 1 DOC 1/21/2021 EtrakitContractor 1ST SUBMITTAL - PLAN SET TIFFANYS SWEET SPOT PLANS.pdf 1 DOC 2/4/2021 KOHL HETRICK FS2021-0001 - COA AND JOB CARD.pdf FS2021-0001 - COA AND JOB CARD.pdf 1 Printed: Friday, February 24, 2023 3:14:03 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FS2021-0001 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org February 4, 2021 Desert Fire Extinguisher PO Box 1607 Palm Springs, CA 92263 Re: Kitchen Suppression System Plan Review – TIFFANY’S SWEET SPOT FS2021-0001 / 78590 HIGHWAY 111, LA QUINTA, CA 92253 The plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department and are approved with the following conditions: o Operation instructions must be posted in a visible location. o The hood/duct system must be monitored by the fire alarm system if building is currently monitored. o In a pre-engineered system, only listed components from a single manufacturer shall be used. o When hood/duct system is activated, the gas supply, electric supply, and make up air must automatically shut off. The hood exhaust fan shall remain on after system activation. o A “K” rated extinguisher must be mounted in the kitchen area. The “K” rated extinguisher shall not substitute for the required conventional dry chemical extinguishers in the kitchen. The following inspections/tests shall be witnessed by the Fire Department: o System operation checkout and final test to be performed by the installer. Alarm company representative must also be present at the time of hood/duct inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78590 HIGHWAY 111 PERMIT#: FS2021-0001 DATE ISSUED: 2/4/2021 DESCRIPTION: TIFFANY’S SWEET SPOT CONTRACTOR: DESERT FIRE HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.