FS2022-0002 (2)ADDITIONAL SITES
CHRONOLOGY
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT ECHO FIRE PROTECTION CO PO BOX 862 GLENDORA CA 91740 (626)331-0819 MDONNELL@ECHOFIR
EPROTECTION.COM
BILL TO Echo Fire Protection Co.P O Box 862 Glendora CA 91702917
4
(626)331-0819 mdonnell@echofirepro
tection.com
CONTRACTOR Michael Donnell PO BOX 862 GLENDORA CA 91740 (626)331-0819 MDONNELL@ECHOFIR
EPROTECTION.COM
OWNER Streivor Inc.2150 Kitty Hawk rd.Livermore CA 91740945
5
(626)331-0819 mdonnell@echofirepro
tection.com
CONDITIONS
Description: HOOD SUPPRESSION - SILVERROCK SHARED SERVICES
Type: FIRE SUPRESSION (WEB)Subtype: HOOD & DUCT Status: ISSUED Applied: 5/2/2022 ECON
Parcel No: 777490011 Site Address: 52049 SILVERROCK WY LA QUINTA,CA 92253 Approved: 6/6/2022 KHET
Subdivision: Block: Lot: Issued: 6/6/2022 ONLINE
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled:
Valuation: $4,000.00 Occupancy Type: Construction Type: Expired: 12/3/2022 ECON
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details:
FINANCIAL INFORMATION
Printed: Monday, March 06, 2023 1:39:44 PM 1 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FS2022-0002
BOND INFORMATION
INSPECTIONS
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS REMARKS NOTES
1ST FIRE (2 WK)KOHL
HETRICK
5/2/2022 5/16/2022 6/6/2022 APPROVED SEE ATTACHMENTS
1ST PERMIT TECH (1
DAY)
PERMIT TECH
BUCKET
5/2/2022 5/3/2022 5/2/2022 COMPLETE
PARENT PROJECTS
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
FIRE COMMERCIAL
COOKING HOOD AND
DUCT SYSTEMS
101-0000-42421 0 $167.00 $167.00 6/6/22 WEB12019 637539310
95 CREDIT 429191 ECON
FIRE COMMERCIAL
COOKING HOOD AND
DUCT SYSTEMS PC
101-0000-42420 0 $250.00 $250.00 6/6/22 WEB12019 637539310
95 CREDIT 429191 ECON
Total Paid for FIRE FEES: $417.00 $417.00
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 6/6/22 WEB12019 637539310
95 CREDIT 429191 ECON
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/6/22 WEB12019 637539310
95 CREDIT 429191 ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS:$433.00 $433.00
Printed: Monday, March 06, 2023 1:39:44 PM 2 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FS2022-0002
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 5/2/2022 Etrakit Contractor 1ST SUBMITTAL PLAN Silver Rock-Shared
Services.pdf 1
DOC 5/2/2022 Etrakit Contractor 1ST SUBMITTAL
MANUAL Pyro Chem manual.pdf 1
DOC 6/6/2022 KOHL HETRICK FS2022-0002 - COA AND
JOB CARD.pdf
FS2022-0002 - COA AND
JOB CARD.pdf 1
DOC 6/7/2022 KOHL HETRICK FS2022-0002 -
APPROVED PLANS.pdf
FS2022-0002 -
APPROVED PLANS.pdf 1
Printed: Monday, March 06, 2023 1:39:44 PM 3 of 3
Permit Details
City of La Quinta
PERMIT NUMBER
FS2022-0002
By:PERMIT # -
TECHNICAL MANUAL
KITCHEN KNIGHT II Restaurant Fire Suppression Manual
UL EX3830 ULC EX3830
2014-NOV-10 REV. 06
This manual is intended for use with PYRO-CHEM KITCHEN
KNIGHT II Restaurant Fire Suppression Systems.
Those who install, operate, recharge, or maintain these fire
suppression systems should read this entire manual. Specific
responsibilities.
Design, installation, recharge, and maintenance of the system
must conform to the limitations detailed in this manual and per-
formed by an individual who attended a PYRO-CHEM training
program and became trained to install, recharge, design, and
maintain the PYRO-CHEM system.
Fire suppression systems are mechanical devices. They need
periodic care. Maintenance is a vital step in the performance
of your fire suppression system. As such it must be performed
in accordance with NFPA 96 (Standard for the Installation
of Equipment for the Removal of Smoke and Grease-Laden
Vapors from Commercial Cooking Equipment) and NFPA
17A (Standard on Wet Chemical Extinguishing Systems) by
an authorized PYRO-CHEM distributor. To provide maximum
assurance that the fire suppression system will operate effec-
tively and safely, maintenance must be conducted at six-month
intervals, or earlier if the situation dictates. Twelve-year main-
tenance must include agent tank hydrostatic testing.
PART NO. 551274-06
PYRO-CHEM, KITCHEN KNIGHT, and the product names listed in this material are marks
and/or registered marks. Unauthorized use is strictly prohibited.
UL EX3830 ULC EX3830
REV. 06 2014-NOV-10
!
Indicates a hazardous situation in which a person will expe-
rience serious personal injury or death if the situation is not
avoided.
!
Indicates a hazardous situation in which a person could expe-
rience serious personal injury or death if the situation is not
avoided.
!
Indicates a hazardous situation in which a person could expe-
rience minor or moderate personal injury if the situation is not
avoided.
Addresses practices not related to personal injury, such as
a system part malfunctioning, property damage, or system
failure.
NOTICE
Addresses general practices or observations
related to system function that are not related
to personal injury.
UL EX3830 ULC EX3830
2014-NOV-10 REV. 06 PAGE 1
KITCHEN KNIGHT II Restaurant Fire Suppression Manual
UL EX3830 ULC EX3830
2014-NOV-10 REV. 06 PAGE 1
Indicates revised information.
Indicates change in page sequence.
2014-NOV-10 Complete manual has
been reformatted along
with several revised
pages that contain
updated technical
information. For clarity,
all pages have been
changed to Revision 06,
regardless of previous
revision number.
Technical information
changes have been
noted with a revision
indicator ().
DATE PAGE REV. NO. DATE PAGE REV. NO.
UL EX3830 ULC EX3830
PAGE 2 REV. 06 2014-NOV-10
Indicates revised information.
Indicates change in page sequence.
DATE PAGE REV. NO. DATE PAGE REV. NO.
UL EX3470 ULC EX3470
2014-NOV-10 REV. 06 PAGE TOC-1
INTRODUCTION 1-1
Temperature Limitations 1-1
UL Listing 1-1
ULC Listing 1-1
MEA Approval 1-1
CYLINDERS & VALVE 2-1
WET VALVE REBUILDING EQUIPMENT 2-1
Wet Valve Seal Rebuilding Kit 2-1
Pressure Regulator Assembly 2-2
Pressure Regulator Rebuilding Kit 2-2
Model VT-1 Tool 2-2
CYLINDER BRACKETING 2-2
EXTINGUISHING AGENT 2-2
MCH3 MECHANICAL CONTROL HEAD 2-3
ECH3 ELECTRICAL CONTROL HEAD 2-3
NMCH3 MECHANICAL CONTROL HEAD 2-3
EN-MCU3 ENCLOSURE 2-3
EN-S ENCLOSURE 2-4
16 GRAM CO2 CARTRIDGE 2-4
MB-P2 MOUNTING BRACKET 2-4
PNEUMATIC ACTUATING CYLINDERS 2-4
Model PAC-10 2-4
DETECTION EQUIPMENT 2-5
Model FLK-1 2-5
Model FLK-1A 2-5
Model FLH-1 2-5
A-PC Fusible Links 2-6
Thermal Detectors 2-6
Flexible Conduit 2-6
RPS-M – REMOTE PULL STATION 2-7
“QUIK-SEAL” ADAPTOR 2-7
“COMPRESSION-SEAL” ADAPTOR 2-7
“HOOD SEAL” ADAPTOR ASSEMBLY 2-7
GAS SHUT-OFF VALVES 2-8
GV Shut-off Valve 2-8
EGVSO Gas Shut-off Valve 2-8
CORNER PULLEYS 2-9
SBP-1 Corner Pulley 2-9
CBP-1 Corner Pulley 2-9
WBP-1 Corner Pulley 2-9
TEE PULLEY 2-9
WIRE ROPE 2-9
ELECTRICAL SWITCHES 2-10
SM-120 SOLENOID MONITOR 2-10
PIPE AND FITTINGS 2-10
AGENT DISTRIBUTION HOSE AND 2-11
RESTRAINING CABLE KIT 2-11
STAINLESS STEEL ACTUATION HOSE 2-11
NOZZLES 2-11
RUBBER BLOW-OFF CAPS 2-11
SWIVEL ADAPTOR 2-11
NOZZLE AIMING DEVICE 2-12
HORN/STROBE ASSEMBLY 2-12
COMPONENTS LIST 2-13
GENERAL 3-1
NOZZLE COVERAGE AND PLACEMENT 3-1
Duct Protection 3-1
Modularizing Duct 3-2
Transition Ducts 3-3
Electrostatic Precipitator 3-3
Plenum Protection 3-3
Appliance Protection 3-4
Design Chart 3-4
Fryers 3-5
Range (Small) 3-6
High-Proximity Backshelf 3-7
Range (Large) 3-7
Nozzle Positioning Table 3-7
Small Wok 3-9
Large Wok 3-9
Small Griddle 3-10
Large Griddle 3-10
Radiant/Electric Char-Broiler 3-11
Lava Rock Char-Broiler 3-11
Natural Charcoal Char-Broiler 3-12
Mesquite Char-Broiler 3-12
Salamander Broiler 3-12
Upright/Salamander Broiler 3-13
Chain Broiler 3-13
Tilt Skillet/Braising Pan 3-14
SPECIFIC APPLICATION BY MODEL 3-15
Henny Penny Fryer – Models 690, 691, 692 3-15
Henny Penny Fryer – Models 580, 3-16
581, 582, 590, 591, 592, 680, 682
Nieco Broiler – Model MPB-84 3-17
Nieco Broiler – Model JF94E 3-17
PIPING LIMITATIONS 3-18
General Piping Requirements 3-19
Design Steps 3-19
DETECTOR PLACEMENT 3-23
Exhaust Duct(s) 3-23
Electrostatic Precipitator 3-23
Cooking Appliance(s) 3-24
UL EX3470 ULC EX3470
PAGE TOC-2 REV. 06 2014-NOV-10
GENERAL 4-1
CYLINDER INSTALLATION 4-1
CONTROL HEAD INSTALLATION 4-1
Single Cylinder Installation 4-1
Multiple Cylinder Installation 4-2
DETECTOR INSTALLATION 4-4
Fusible Link Detection 4-4
Fusible Links Without Hangers 4-5
Fusible Links With Link Hangers 4-6
Thermal Detection 4-6
SETTING THE CONTROL HEAD 4-7
MCH3/NMCH3 Control Head 4-7
ECH3 Control Head 4-7
SOLENOID MONITOR INSTALLATION 4-8
In Detection Circuit 4-8
Solenoid Monitor When Used as a 4-8
Reset Relay
REMOTE PULL STATION INSTALLATION 4-8
GAS SHUT-OFF VALVE INSTALLATION 4-10
Mechanical Gas Shut-off 4-10
Valve Installation
Electrical Gas Shut-off Valve Installation 4-11
PULLEY TEE INSTALLATION 4-11
ELECTRICAL (SNAP-ACTION) SWITCH 4-11
INSTALLATION
PIPE AND NOZZLE INSTALLATION 4-12
INSTALLATION INSTRUCTIONS FOR 4-13
CASTERED/MOVEABLE EQUIPMENT
USING AGENT DISTRIBUTION HOSE
Critical Installation Requirements 4-13
AGENT DISTRIBUTION HOSE INSTALLATION 4-13
General Requirements 4-13
Installation Requirements 4-13
Restraining Cable Installation 4-14
Final Installation Guidelines and 4-15
Checkout Procedures
Agent Distribution Hose/Restraining 4-16
Cable Six-Month Maintenance
Blank Page 4-17
SYSTEM CHECKOUT AFTER INSTALLATION 4-18
Model MCH3/NMCH3 Mechanical 4-18
Control Head
Model ECH3-24/120 Electrical 4-18
Control Head
Testing Thermal Detectors 4-18
Testing Remote Pull Station 4-18
Completing System Checkout 4-19
ENCLOSURE INSTALLATION INSTRUCTIONS 4-19
– MODEL EN-MCU3 AND MODEL EN-S
Enclosure Mounting 4-19
Fusible Link Detector Installation 4-20
Setting the EN-MCU3 4-20
Remote Pull Station Installation 4-20
Gas Shut-off Valve Installation 4-20
Electrical (Snap-Action) Switch Installation 4-21
Cylinder Installation 4-21
Single Cylinder Installation 4-21
Multiple Cylinder Installation 4-22
System Checkout After Installation 4-22
FLEXIBLE CONDUIT INSTALLATION 4-23
Design Requirements 4-23
Installation Requirements 4-24
Connecting Flexible Conduit to Control 4-24
Head, Electrical Box, Pull Station, or
Mechanical Gas Valve
Connecting Flexible Conduit to Pulley 4-26
Elbows, Pulley Tees, or Union Fittings
Installing Flexible Conduit Through a 4-27
Conduit Offset
Flexible Conduit Splicing 4-29
Testing Pull Station/Mechanical Gas Valve 4-31
GENERAL 5-1
SEMI-ANNUAL MAINTENANCE 5-1
ANNUAL MAINTENANCE 5-1
12-YEAR MAINTENANCE 5-2
GENERAL 6-1
SYSTEM CLEANUP 6-1
SYSTEM RECHARGE 6-1
!
!
!
!
!
!
!
!
OFFICE OF THE FIRE MARSHAL – LA QUINTA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
June 6, 2022
Echo Fire Protection
PO Box 862
Glendora, CA 91702
Re: Kitchen Suppression System Plan Review – SILVERROCK – SHARED SERVICES
FS2022-0002 / 52049 SILVERROCK WAY, LA QUINTA, CA 92253
The plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department
and are approved with the following conditions:
o Operation instructions must be posted in a visible location.
o The hood/duct system must be monitored by the fire alarm system if building is currently monitored.
o In a pre-engineered system, only listed components from a single manufacturer shall be used.
o When hood/duct system is activated, the gas supply, electric supply, and make up air must automatically shut
off. The hood exhaust fan shall remain on after system activation.
o A “K” rated extinguisher must be mounted in the kitchen area. The “K” rated extinguisher shall not substitute
for the required conventional dry chemical extinguishers in the kitchen.
The following inspections/tests shall be witnessed by the Fire Department:
o System operation checkout and final test to be performed by the installer. Alarm company representative must
also be present at the time of hood/duct inspection.
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
RIVERSIDE COUNTY FIRE PROTECTION PLANNING
RECORD OF INSPECTIONS / PERMIT CARD
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS: 52049 SILVERROCK WAY PERMIT#: FS2022-0002 DATE
ISSUED: 6/6/2022
DESCRIPTION: SHARED SERVICES – HOOD SUPP CONTRACTOR: ECHO FIRE PROTECTION
HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS
Thrust block pre-pour Door fan test
UG rough piping Abort test
UG hydro Mechanical shutdown
Flush Detector test
Final E F Deluge/pre-action
SPRINKLER U.G. Final E F
Thrust block pre-pour UST/AST TANK
UG rough piping Installation
UG hydro Removal
Flush Emergency shut off
Final E F Primary piping
FIRE SPRINKLER Secondary piping
Weld inspection Dispensers & shear valves
Overhead rough piping Final E F
Overhead hydro MISC. INSPECTIONS
UG flush / OK to connect Spray booths
Main drain/inspectors’ test Hood/duct extinguishing
High pile storage High pile rack storage
In-rack sprinklers H.P. vents/access/corridors
Hose racks Tract access/hydrant verification
Final E F Access & Address verification
HOOD EXTINGUISHING OTHER CONST. PERMIT
Detection system
Function test
Gas/electrical shut-off
Nozzle model/placement
Fire alarm connection
Final E F
SPRAY BOOTHS FIRE CODE PERMIT(S)
Installation
Air flow test
Mechanical interlock
Extinguishing system
Fire alarm connection
Final E F
FIRE ALARM KNOX SYSTEM
Rough-wire inspection Building Knox box
Function test Gate access Knox box/padlock
Duct detectors/velocity BUILDING INSPECTIONS
24 hr. battery test T/I final
Sprinkler monitoring Shell final
Final E F Final for occupancy
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE**
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspections. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.