Loading...
FS2022-0002 (2)ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT ECHO FIRE PROTECTION CO PO BOX 862 GLENDORA CA 91740 (626)331-0819 MDONNELL@ECHOFIR EPROTECTION.COM BILL TO Echo Fire Protection Co.P O Box 862 Glendora CA 91702917 4 (626)331-0819 mdonnell@echofirepro tection.com CONTRACTOR Michael Donnell PO BOX 862 GLENDORA CA 91740 (626)331-0819 MDONNELL@ECHOFIR EPROTECTION.COM OWNER Streivor Inc.2150 Kitty Hawk rd.Livermore CA 91740945 5 (626)331-0819 mdonnell@echofirepro tection.com CONDITIONS Description: HOOD SUPPRESSION - SILVERROCK SHARED SERVICES Type: FIRE SUPRESSION (WEB)Subtype: HOOD & DUCT Status: ISSUED Applied: 5/2/2022 ECON Parcel No: 777490011 Site Address: 52049 SILVERROCK WY LA QUINTA,CA 92253 Approved: 6/6/2022 KHET Subdivision: Block: Lot: Issued: 6/6/2022 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $4,000.00 Occupancy Type: Construction Type: Expired: 12/3/2022 ECON No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Monday, March 06, 2023 1:39:44 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FS2022-0002 BOND INFORMATION INSPECTIONS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 5/2/2022 5/16/2022 6/6/2022 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 5/2/2022 5/3/2022 5/2/2022 COMPLETE PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE COMMERCIAL COOKING HOOD AND DUCT SYSTEMS 101-0000-42421 0 $167.00 $167.00 6/6/22 WEB12019 637539310 95 CREDIT 429191 ECON FIRE COMMERCIAL COOKING HOOD AND DUCT SYSTEMS PC 101-0000-42420 0 $250.00 $250.00 6/6/22 WEB12019 637539310 95 CREDIT 429191 ECON Total Paid for FIRE FEES: $417.00 $417.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 6/6/22 WEB12019 637539310 95 CREDIT 429191 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/6/22 WEB12019 637539310 95 CREDIT 429191 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$433.00 $433.00 Printed: Monday, March 06, 2023 1:39:44 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FS2022-0002 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/2/2022 Etrakit Contractor 1ST SUBMITTAL PLAN Silver Rock-Shared Services.pdf 1 DOC 5/2/2022 Etrakit Contractor 1ST SUBMITTAL MANUAL Pyro Chem manual.pdf 1 DOC 6/6/2022 KOHL HETRICK FS2022-0002 - COA AND JOB CARD.pdf FS2022-0002 - COA AND JOB CARD.pdf 1 DOC 6/7/2022 KOHL HETRICK FS2022-0002 - APPROVED PLANS.pdf FS2022-0002 - APPROVED PLANS.pdf 1 Printed: Monday, March 06, 2023 1:39:44 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FS2022-0002 By:PERMIT # - TECHNICAL MANUAL KITCHEN KNIGHT II Restaurant Fire Suppression Manual UL EX3830 ULC EX3830 2014-NOV-10 REV. 06 This manual is intended for use with PYRO-CHEM KITCHEN KNIGHT II Restaurant Fire Suppression Systems. Those who install, operate, recharge, or maintain these fire suppression systems should read this entire manual. Specific responsibilities. Design, installation, recharge, and maintenance of the system must conform to the limitations detailed in this manual and per- formed by an individual who attended a PYRO-CHEM training program and became trained to install, recharge, design, and maintain the PYRO-CHEM system. Fire suppression systems are mechanical devices. They need periodic care. Maintenance is a vital step in the performance of your fire suppression system. As such it must be performed in accordance with NFPA 96 (Standard for the Installation of Equipment for the Removal of Smoke and Grease-Laden Vapors from Commercial Cooking Equipment) and NFPA 17A (Standard on Wet Chemical Extinguishing Systems) by an authorized PYRO-CHEM distributor. To provide maximum assurance that the fire suppression system will operate effec- tively and safely, maintenance must be conducted at six-month intervals, or earlier if the situation dictates. Twelve-year main- tenance must include agent tank hydrostatic testing. PART NO. 551274-06 PYRO-CHEM, KITCHEN KNIGHT, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. UL EX3830 ULC EX3830 REV. 06 2014-NOV-10 ! Indicates a hazardous situation in which a person will expe- rience serious personal injury or death if the situation is not avoided. ! Indicates a hazardous situation in which a person could expe- rience serious personal injury or death if the situation is not avoided. ! Indicates a hazardous situation in which a person could expe- rience minor or moderate personal injury if the situation is not avoided. Addresses practices not related to personal injury, such as a system part malfunctioning, property damage, or system failure. NOTICE Addresses general practices or observations related to system function that are not related to personal injury. UL EX3830 ULC EX3830 2014-NOV-10 REV. 06 PAGE 1 KITCHEN KNIGHT II Restaurant Fire Suppression Manual UL EX3830 ULC EX3830 2014-NOV-10 REV. 06 PAGE 1 Indicates revised information. Indicates change in page sequence. 2014-NOV-10 Complete manual has been reformatted along with several revised pages that contain updated technical information. For clarity, all pages have been changed to Revision 06, regardless of previous revision number. Technical information changes have been noted with a revision indicator (). DATE PAGE REV. NO. DATE PAGE REV. NO. UL EX3830 ULC EX3830 PAGE 2 REV. 06 2014-NOV-10 Indicates revised information. Indicates change in page sequence. DATE PAGE REV. NO. DATE PAGE REV. NO. UL EX3470 ULC EX3470 2014-NOV-10 REV. 06 PAGE TOC-1 INTRODUCTION 1-1 Temperature Limitations 1-1 UL Listing 1-1 ULC Listing 1-1 MEA Approval 1-1 CYLINDERS & VALVE 2-1 WET VALVE REBUILDING EQUIPMENT 2-1 Wet Valve Seal Rebuilding Kit 2-1 Pressure Regulator Assembly 2-2 Pressure Regulator Rebuilding Kit 2-2 Model VT-1 Tool 2-2 CYLINDER BRACKETING 2-2 EXTINGUISHING AGENT 2-2 MCH3 MECHANICAL CONTROL HEAD 2-3 ECH3 ELECTRICAL CONTROL HEAD 2-3 NMCH3 MECHANICAL CONTROL HEAD 2-3 EN-MCU3 ENCLOSURE 2-3 EN-S ENCLOSURE 2-4 16 GRAM CO2 CARTRIDGE 2-4 MB-P2 MOUNTING BRACKET 2-4 PNEUMATIC ACTUATING CYLINDERS 2-4 Model PAC-10 2-4 DETECTION EQUIPMENT 2-5 Model FLK-1 2-5 Model FLK-1A 2-5 Model FLH-1 2-5 A-PC Fusible Links 2-6 Thermal Detectors 2-6 Flexible Conduit 2-6 RPS-M – REMOTE PULL STATION 2-7 “QUIK-SEAL” ADAPTOR 2-7 “COMPRESSION-SEAL” ADAPTOR 2-7 “HOOD SEAL” ADAPTOR ASSEMBLY 2-7 GAS SHUT-OFF VALVES 2-8 GV Shut-off Valve 2-8 EGVSO Gas Shut-off Valve 2-8 CORNER PULLEYS 2-9 SBP-1 Corner Pulley 2-9 CBP-1 Corner Pulley 2-9 WBP-1 Corner Pulley 2-9 TEE PULLEY 2-9 WIRE ROPE 2-9 ELECTRICAL SWITCHES 2-10 SM-120 SOLENOID MONITOR 2-10 PIPE AND FITTINGS 2-10 AGENT DISTRIBUTION HOSE AND 2-11 RESTRAINING CABLE KIT 2-11 STAINLESS STEEL ACTUATION HOSE 2-11 NOZZLES 2-11 RUBBER BLOW-OFF CAPS 2-11 SWIVEL ADAPTOR 2-11 NOZZLE AIMING DEVICE 2-12 HORN/STROBE ASSEMBLY 2-12 COMPONENTS LIST 2-13 GENERAL 3-1 NOZZLE COVERAGE AND PLACEMENT 3-1 Duct Protection 3-1 Modularizing Duct 3-2 Transition Ducts 3-3 Electrostatic Precipitator 3-3 Plenum Protection 3-3 Appliance Protection 3-4 Design Chart 3-4 Fryers 3-5 Range (Small) 3-6 High-Proximity Backshelf 3-7 Range (Large) 3-7 Nozzle Positioning Table 3-7 Small Wok 3-9 Large Wok 3-9 Small Griddle 3-10 Large Griddle 3-10 Radiant/Electric Char-Broiler 3-11 Lava Rock Char-Broiler 3-11 Natural Charcoal Char-Broiler 3-12 Mesquite Char-Broiler 3-12 Salamander Broiler 3-12 Upright/Salamander Broiler 3-13 Chain Broiler 3-13 Tilt Skillet/Braising Pan 3-14 SPECIFIC APPLICATION BY MODEL 3-15 Henny Penny Fryer – Models 690, 691, 692 3-15 Henny Penny Fryer – Models 580, 3-16 581, 582, 590, 591, 592, 680, 682 Nieco Broiler – Model MPB-84 3-17 Nieco Broiler – Model JF94E 3-17 PIPING LIMITATIONS 3-18 General Piping Requirements 3-19 Design Steps 3-19 DETECTOR PLACEMENT 3-23 Exhaust Duct(s) 3-23 Electrostatic Precipitator 3-23 Cooking Appliance(s) 3-24 UL EX3470 ULC EX3470 PAGE TOC-2 REV. 06 2014-NOV-10 GENERAL 4-1 CYLINDER INSTALLATION 4-1 CONTROL HEAD INSTALLATION 4-1 Single Cylinder Installation 4-1 Multiple Cylinder Installation 4-2 DETECTOR INSTALLATION 4-4 Fusible Link Detection 4-4 Fusible Links Without Hangers 4-5 Fusible Links With Link Hangers 4-6 Thermal Detection 4-6 SETTING THE CONTROL HEAD 4-7 MCH3/NMCH3 Control Head 4-7 ECH3 Control Head 4-7 SOLENOID MONITOR INSTALLATION 4-8 In Detection Circuit 4-8 Solenoid Monitor When Used as a 4-8 Reset Relay REMOTE PULL STATION INSTALLATION 4-8 GAS SHUT-OFF VALVE INSTALLATION 4-10 Mechanical Gas Shut-off 4-10 Valve Installation Electrical Gas Shut-off Valve Installation 4-11 PULLEY TEE INSTALLATION 4-11 ELECTRICAL (SNAP-ACTION) SWITCH 4-11 INSTALLATION PIPE AND NOZZLE INSTALLATION 4-12 INSTALLATION INSTRUCTIONS FOR 4-13 CASTERED/MOVEABLE EQUIPMENT USING AGENT DISTRIBUTION HOSE Critical Installation Requirements 4-13 AGENT DISTRIBUTION HOSE INSTALLATION 4-13 General Requirements 4-13 Installation Requirements 4-13 Restraining Cable Installation 4-14 Final Installation Guidelines and 4-15 Checkout Procedures Agent Distribution Hose/Restraining 4-16 Cable Six-Month Maintenance Blank Page 4-17 SYSTEM CHECKOUT AFTER INSTALLATION 4-18 Model MCH3/NMCH3 Mechanical 4-18 Control Head Model ECH3-24/120 Electrical 4-18 Control Head Testing Thermal Detectors 4-18 Testing Remote Pull Station 4-18 Completing System Checkout 4-19 ENCLOSURE INSTALLATION INSTRUCTIONS 4-19 – MODEL EN-MCU3 AND MODEL EN-S Enclosure Mounting 4-19 Fusible Link Detector Installation 4-20 Setting the EN-MCU3 4-20 Remote Pull Station Installation 4-20 Gas Shut-off Valve Installation 4-20 Electrical (Snap-Action) Switch Installation 4-21 Cylinder Installation 4-21 Single Cylinder Installation 4-21 Multiple Cylinder Installation 4-22 System Checkout After Installation 4-22 FLEXIBLE CONDUIT INSTALLATION 4-23 Design Requirements 4-23 Installation Requirements 4-24 Connecting Flexible Conduit to Control 4-24 Head, Electrical Box, Pull Station, or Mechanical Gas Valve Connecting Flexible Conduit to Pulley 4-26 Elbows, Pulley Tees, or Union Fittings Installing Flexible Conduit Through a 4-27 Conduit Offset Flexible Conduit Splicing 4-29 Testing Pull Station/Mechanical Gas Valve 4-31 GENERAL 5-1 SEMI-ANNUAL MAINTENANCE 5-1 ANNUAL MAINTENANCE 5-1 12-YEAR MAINTENANCE 5-2 GENERAL 6-1 SYSTEM CLEANUP 6-1 SYSTEM RECHARGE 6-1 ! ! ! ! ! ! ! ! OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org June 6, 2022 Echo Fire Protection PO Box 862 Glendora, CA 91702 Re: Kitchen Suppression System Plan Review – SILVERROCK – SHARED SERVICES FS2022-0002 / 52049 SILVERROCK WAY, LA QUINTA, CA 92253 The plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department and are approved with the following conditions: o Operation instructions must be posted in a visible location. o The hood/duct system must be monitored by the fire alarm system if building is currently monitored. o In a pre-engineered system, only listed components from a single manufacturer shall be used. o When hood/duct system is activated, the gas supply, electric supply, and make up air must automatically shut off. The hood exhaust fan shall remain on after system activation. o A “K” rated extinguisher must be mounted in the kitchen area. The “K” rated extinguisher shall not substitute for the required conventional dry chemical extinguishers in the kitchen. The following inspections/tests shall be witnessed by the Fire Department: o System operation checkout and final test to be performed by the installer. Alarm company representative must also be present at the time of hood/duct inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 52049 SILVERROCK WAY PERMIT#: FS2022-0002 DATE ISSUED: 6/6/2022 DESCRIPTION: SHARED SERVICES – HOOD SUPP CONTRACTOR: ECHO FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.