Loading...
FS2022-0004 (2)ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT ECHO FIRE PROTECTION CO PO BOX 862 GLENDORA CA 91740 (626)331-0819 MDONNELL@ECHOFIR EPROTECTION.COM BILL TO Michael Donnell P O Box 862 Glendora CA 91740 (626)331-0819 mdonnell@echofirepro tection.com CONTRACTOR ECHO FIRE PROTECTION CO P O Box 862 Glendora CA 91740 (626)331-0819 mdonnell@echofirepro tection.com OWNER Streivor Inc.2150 Kitty Hawk rd.Livermore Ca 94551 (626)331-0819 CONDITIONS Description: HOOD SUPRESSION - MONTAGE CONFERENCE CENTER Type: FIRE SUPRESSION (WEB)Subtype: HOOD & DUCT Status: ISSUED Applied: 5/4/2022 ECON Parcel No: 777490011 Site Address: 52027 SILVERROCK WY LA QUINTA,CA 92253 Approved: 6/7/2022 KHET Subdivision: Block: Lot: Issued: 6/8/2022 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $10,000.00 Occupancy Type: Construction Type: Expired: 12/5/2022 ECON No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Monday, March 06, 2023 1:49:49 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FS2022-0004 BOND INFORMATION INSPECTIONS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)KOHL HETRICK 5/4/2022 5/18/2022 6/7/2022 APPROVED SEE ATTACHMENTS 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 5/4/2022 5/5/2022 5/4/2022 COMPLETE PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE COMMERCIAL COOKING HOOD AND DUCT SYSTEMS 101-0000-42421 0 $167.00 $167.00 6/8/22 WEB12048 637563392 22 CREDIT 429191 ECON FIRE COMMERCIAL COOKING HOOD AND DUCT SYSTEMS PC 101-0000-42420 0 $250.00 $250.00 6/8/22 WEB12048 637563392 22 CREDIT 429191 ECON Total Paid for FIRE FEES: $417.00 $417.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 6/8/22 WEB12048 637563392 22 CREDIT 429191 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/8/22 WEB12048 637563392 22 CREDIT 429191 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$433.00 $433.00 Printed: Monday, March 06, 2023 1:49:49 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FS2022-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/4/2022 Etrakit Contractor 1ST SUBMITTAL PLANS Silver Rock-Conference Center-Plans.pdf 1 DOC 5/4/2022 Etrakit Contractor 1ST SUBMITTAL SPECS Pyro Chem manual.pdf 1 DOC 6/7/2022 KOHL HETRICK FS2022-0004 - APPROVED PLANS.pdf FS2022-0004 - APPROVED PLANS.pdf 1 DOC 6/7/2022 KOHL HETRICK FS2022-0004 - COA AND JOB CARD.pdf FS2022-0004 - COA AND JOB CARD.pdf 1 Printed: Monday, March 06, 2023 1:49:49 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FS2022-0004 DUCT NOZZLE COVERAGE 2D: 100" PERIMETER 2D 11 10 DUCT NOZZLE COVERAGE 2D: 100" PERIMETER 2D 11 10 1H PLENUM NOZZLE COVERAGE 1H: 120 LONG x 48 WIDE 73 x 18 1H PLENUM NOZZLE COVERAGE 1H: 120 LONG x 48 WIDE 74 x 18 DUCT NOZZLE COVERAGE 2D: 100" PERIMETER 2D 15 10 DUCT NOZZLE COVERAGE 2D: 100" PERIMETER 2D 15 10 1H PLENUM NOZZLE COVERAGE 1H: 120 LONG x 48 WIDE 75 x 18 1H PLENUM NOZZLE COVERAGE 1H: 120 LONG x 48 WIDE 75 x 18 DUCT NOZZLE COVERAGE 2D: 100" PERIMETER 2D 17 10 1H PLENUM NOZZLE COVERAGE 1H: 120 LONG x 48 WIDE 114 x 18 2H 12 2H 13 2H 13 26 155 8 2H 155 8 2H 155 8 2H 2712 24 1H 24 2H 24 1H 24 2L 28 24 2L 24 2H MAX COVERAGE: TILT SKILLET 2H: 27.75x18 FRYER 2H: 18x27.75 FRYER 2H: 18x27.75 FRYER 2H: 18x27.75 1H: 24x26 GAS RADIANT BROILER GRIDDLE 2H: 30x36 1H: 24x26 GAS RADIANT BROILER RANGE 2L: 28x28 RANGE 2L: 28x28 GRIDDLE 2H: 30x36 TILT KETTLE OVEN OVEN NOTES TO ARCHITECT AND/OR CONTRACTOR: STREIVOR, INC. (STREIVOR AIR SYSTEMS, STREIVOR STAINLESS) IS A SPECIALIST IN THE LAYOUT AND DESIGN OF KITCHEN VENTILATION SYSTEMS, AND IN NO WAY PURPORTS TO BE ARCHITECTS OR ENGINEERS. THIS PLAN IS SUBMITTED FOR THE CONVENIENCE OF THE ARCHITECT AND/OR CONTRACTOR AND IS DONE FROM AVAILABLE ARCHITECTURAL INFORMATION. ALL MEASUREMENTS ARE SUBJECT TO PHYSICAL VERIFICATION AND ANY DEVIATIONS OR DISCREPANCIES SHALL BE DIRECTED TO THE ATTENTION OF STREIVOR, INC. IN WRITING. STREIVOR, INC. ACCEPTS NO RESPONSIBILITY FOR WORK DONE BY SAID ARCHITECT OR GENERAL CONTRACTOR OR THEIR REPRESENTATIVES OR SUBCONTRACTORS, AND WILL NOT STAND ANY EXPENSE FOR CHANGES MADE NECESSARY DUE TO LOCAL BUILDING CODES, ORDINANCES, STRUCTURAL CONDITIONS, OR BY ANY SUBSTITUTIONS OR CHANGES IN EQUIPMENT SHOWN ON THIS PLAN. ANY ERRORS, AMBIGUITIES OR OMISSIONS IN THIS PLAN OR SPECIFICATIONS SHALL BE REPORTED TO STREIVOR, INC. FOR CORRECTIONS BEFORE ANY OF THE WORK IS STARTED. UNLESS EXPRESSLY STIPULATED, NO ADDITIONAL ALLOWANCE WILL BE MADE IN FAVOR OF THE OWNER OR CONTRACTOR. BY VIRTUE OF ERROR, AMBIGUITY OR OMISSION WHICH SHOULD HAVE BEEN DISCOVERED DURING THE PREPARATION OF BID ESTIMATES, AND DIRECTED TO THE ATTENTION OF STREIVOR, INC. IN A TIMELY MANNER. GENERAL NOTES: SYSTEM #1 - HOOD #113 INSTALLER: DESCRIPTION DATE INT DATE: SCALE: DRAWN BY: CHECKED BY: CONSULTANT: 1/2" = 1' - 0" HOOD #: IF BAR DOES NOT MEASURE 1" THIS DRAWING IS NOT PLOTTED TO SCALE (UNLESS OTHERWISE NOTED) SYSTEM #: 147 ITEM #: CYLINDER #1 FROM WALL MOUNTED UTILITY CABINET ------/--/----- ------/--/----- ------/--/----- ------/--/----- ------/--/----- --- --- --- --- DRAWING: F-01 SHEET OF01 03 HIGH BACK SHELVES YES NO PULL STATION LOCATION(S)YES NO UTILITY CABINET LOCATION(S)YES NO YES NO AGENT DISTRIBUTION HOSE AND RESTRAINING CABLE KIT RANGE COOKING SURFACE DEPTH GREATER THAN 28" YES NO COOKING EQUIPMENT VERIFICATION CEILING HEIGHT ' - " NOTE TO REVIEWER: ANY CHANGES IN COOKING EQUIPMENT SUCH AS EQUIPMENT POSITION, TYPE AND/OR INCREASE IN ENERGY OUTPUT MAY EFFECT EXHAUST AIRFLOW. STREIVOR AIR SYSTEMS MUST BE NOTIFIED OF ANY CHANGES THAT OCCUR PRIOR TO FABRICATION, A RE-ENGINEERING OF THE EXHAUST AIRFLOW MAY BE REQUIRED. ADDITIONAL SITE VISIT FOR FIRE SUPPRESSION PRE-TEST IS NOT INCLUDED UNLESS SPECIFICALLY LISTED IN QUOTE. CUSTOMER APPROVAL VERIFY THE FOLLOWING: _____________________________________ APPROVED BY DATE 63 2150 KITTY HAWK ROAD, LIVERMORE, CA 94551PHONE: (925) 960-9090 FAX:(925) 960-9055WWW.STREIVOR.COM COPYRIGHT © 2021 STREIVOR, INC. PROJECT: INSTALLATION REQUIREMENTS 1.ALL PIPE SHALL BE SCHEDULE 40 BLACK IRON. CHROME PLATED/SLEEVED WHERE EXPOSED. 2.ALL CYLINDER SYSTEMS SHALL HAVE 3/8" SUPPLY LINES AND 3/8" BRANCH LINES. 3.ALL WIRE ROPE SHALL BE 1/16" STAINLESS STEEL AND RUN THROUGH 1/2" EMT CONDUIT. 4.U.L. LISTED CORNER PULLEYS REQUIRED WHENEVER THE STAINLESS STEEL CABLE DIRECTION CHANGES. 5.ALL EQUIPMENT WITH FIRE PROTECTION MUST BE SECURED TO FLOOR. (NOT BY STREIVOR) 6.SWIVEL ADAPTERS MAY BE ADDED TO NOZZLES FOR UP TO 30° ROTATION. R THIS WET CHEMICAL EXTINGUISHING SYSTEM IS ENGINEERED TO PROVIDE FIRE PROTECTION FOR RESTAURANT HOODS, DUCTS AND COOKING APPLIANCES, IS UL 300 LISTED AND IS TO BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS: LISTINGS & STANDARDS N PFAR 300 ·NFPA 17A 2017 EDITION ·NFPA 10 2018 EDITION ·NFPA 96 2017 EDITION SECTIONS & CODES NFPA 10 2018 EDITION (6.6.2) MAXIMUM TRAVEL DISTANCE SHALL NOT EXCEED 30 FT (9.1 M) FROM THE HAZARD TO THE EXTINGUISHER(S) NFPA 17A 2017 EDITION (5.2.1.10.1) EACH MANUAL ACTUATION DEVICE SHALL BE INSTALLED NO MORE THAN 48 IN. (1200 MM) AND NO LESS THAN 42 IN. (1067 MM) ABOVE THE FLOOR. NFPA 96 2017 EDITION (8.2.3.1)A HOOD EXHAUST FAN(S) SHALL CONTINUE TO OPERATE AFTER THE EXTINGUISHING SYSTEM HAS BEEN ACTIVATED UNLESS FAN SHUTDOWN IS REQUIRED BY A LISTED COMPONENT OF THE VENTILATION SYSTEM OR BY THE DESIGN OF THE EXTINGUISHING SYSTEM. (8.2.3.2)THE HOOD EXHAUST FAN SHALL START UPON ACTIVATION OF THE EXTINGUISHING SYSTEM IF THE EXHAUST FAN AND ALL COOKING EQUIPMENT SERVED BY THE FAN HAVE BEEN SHUT DOWN, UNLESS FAN SHUTDOWN IS REQUIRED BY A LISTED COMPONENT OF THE VENTILATION SYSTEM OR BY THE LISTING OF THE EXTINGUISHING SYSTEM. (8.3.2)WHEN THE FIRE-EXTINGUISHING SYSTEM ACTIVATES, MAKEUP AIR SUPPLIED INTERNALLY TO A HOOD SHALL BE SHUT OFF. (10.4.1)UPON ACTIVATION OF ANY FIRE EXTINGUISHING SYSTEM FOR A COOKING OPERATION, ALL SOURCES OF FUEL AND ELECTRICAL POWER THAT PRODUCE HEAT TO ALL EQUIPMENT REQUIRING PROTECTION BY THAT SYSTEM SHALL AUTOMATICALLY SHUT OFF. (10.4.3)ANY GAS APPLIANCE NOT REQUIRING PROTECTION BUT LOCATED UNDER VENTILATING EQUIPMENT WHERE PROTECTED APPLIANCES ARE LOCATED SHALL BE AUTOMATICALLY SHUT OFF UPON ACTIVATION OF THE EXTINGUISHING SYSTEM (10.4.4)SHUTOFF DEVICE SHALL REQUIRE MANUAL RESET. (10.5.1.1)AT LEAST ONE MANUAL ACTUATION DEVICE SHALL BE LOCATED IN A MEANS OF EGRESS OR AT A LOCATION ACCEPTABLE TO THE AHJ. (10.5.1.2)THE MANUAL ACTUATION DEVICE SHALL CLEARLY IDENTIFY THE HAZARD PROTECTED. CMC 2018 EDITION (513.5) MANUAL ACTIVATION SHALL BE ACCESSIBLE IN THE EVENT OF A FIRE. NOT LESS THAN ONE MANUAL ACTUATION DEVICE SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) AND NOT MORE THAN 20 FEET (6096 MM) FROM THE PROTECTED EXHAUST SYSTEM(S). [IBC 2018: 904.12.1]DUCTPLENUMAPPLIANCEZONE COVERAGE CYLINDER #1 COVERAGE DESCRIPTION NOZZLE FLOW POINTSQTY.PAGE TOTAL FLOW POINTS PIPING LIMITATIONS MAXIMUM ALLOTTED CYLINDER FLOW POINTS TOTAL FIRST TO LAST NOZZZLE LENGTH*VOLUME LENGTH*VOLUME FT ML FT ML PCL-460 14 90.67 3400 80.00 3000 FT ML FT ML1345.00 1688 32.00 1200 13 LEGEND 24 APPLIANCE NOZZLE AND HEIGHT CONTROL HEAD DETECTOR BRACKET (FRONT VIEW) DETECTOR BRACKET (PLAN VIEW) DOWNWARD FACING NOZZLE ANGLED NOZZLE AND TARGET LOCATION PULL STATION NOZZLE COVERAGE K-CLASS FIRE EXTINGUISHER (NOT SUPPLIED BY STREIVOR) PIPING FIELD PIPING PATH OF EGRESS PAC-10 PNEUMATIC TUBING DETECTION LINE ROUTE 48 1H 1X 1X 120 1H PLENUM NOZZLE MAX PLENUM LENGTH DUCT NOZZLE MAX PERIMETER100 2D PS K GAS VALVEGV RESET RELAYRR FIELD WIRING NOT BY STRIEVOR CYLINDER #3 FROM WALL MOUNTED UTILITY CABINET CYLINDER #2 FROM WALL MOUNTED UTILITY CABINET TO ACTIVATE FIRE SUPPRESSION SYSTEM PULL STATION IN CASE OF FIRE PULL 4x4 J-BOX TO BE RECESSED OR SURFACE MOUNT "D" RING PULL HANDLE RED PLASTIC BREAK ROD ALUMINUM FACE PLATE (PART # 551074) FINISHED CEILING 12" E.M.T. CONDUIT (RECESSED) 42"-48" A.F.F. STUBBED MIN. 6" ABOVE FINISHED CEILING FINISHED FLOOR CORNER PULLEY PROVIDED BY FIRE SUPPRESSION INSTALLER 2" CL NMCH3 CONTROL HEAD PULL STATION CONNECTION N.C.N.O.COMLOW VOLTAGE ALARM SWITCH WIRING ·EXCEPT FOR ALARM INITIATING SWITCH, NO ELECTRICAL CONNECTIONS ARE TO BE MADE INSIDE THE CONTROL HEAD ENCLOSURE. (PART # 551203) ELECTRICAL SWITCHES SPARE ELECTRICAL SWITCH TO DEMANDAIRE CONTROL PANEL TO BUILDING ALARM ELECTRICAL SWITCH WIRING ·REFER TO NFPA 96 CODES 8.3.2 & 10.4.1 FOR MORE INFORMATION ·SHUNT DEVICE TO BE NORMALLY OPEN (NOT PROVIDED BY STREIVOR) ·EXCEPT FOR ALARM INITIATING SWITCH, NO ELECTRICAL CONNECTIONS ARE TO BE MADE INSIDE THE CONTROL HEAD ENCLOSURE. SPARE ELECTRICAL SWITCH ALARM SWITCH N.C. N.O. COM NORMALLY OPEN (BLACK) COMMON (RED) NORMALLY CLOSED (BROWN) ACTUATING ARM ·QUANTITY: 1 ·SWITCH IS RATED AT 28 VDC, 50 mA ·FIRE SUPPRESSION SYSTEM TO BE FIELD WIRED INTO BUILDING FIRE ALARM SYSTEM (BY OTHERS). (PART # 550077) N.C. N.O. COM ACTUATING ARM PRESS CONNECTOR TIGHTLY AGAINST SWITCH COMMON (RED) NORMALLY OPEN (BLACK) NORMALLY CLOSED (BROWN) ·QUANITITY: 3 ·SWITCH IS RATED AT 250 VAC, 21A RESISTIVE; 250 VAC, 2 HP; 125 VAC, 1 HP ELECTRICAL SWITCH (PART # 551154) SECTION A-A A A ELECTRIC GAS SHUT-OFF VALVE & FLANGED Y-STRAINER ·GAS SHUT-OFF VALVE(S) TO BE SIZED AND LOCATED PER MEP DRAWINGS (MAXIMUM VALVE SIZE: 3" NPT) ·VALVE(S) AND STRAINERS TO BE INSTALLED BY DIVISION 22 (PLUMBING) ·EACH VALVE REQUIRES SEPARATE 120VAC/1, 15A CIRCUIT ·ACTIVATION OF THE FIRE EXTINGUISHING SYSTEM WILL SHUT OFF THE VALVE PREVENTING GAS FLOW AND WILL REMAIN CLOSED UNTIL THE RESET RELAY IS MANUALLY PRESSED. ·Y-STRAINER REQUIRED FOR THE PROTECTION OF THE GAS VALVE. INSTALL A Y-STRAINER ON THE INLET SIDE OF THE GAS VALVE (AS CLOSE AS POSSIBLE). Y-STRAINER NOT PROVIDED BY STREIVOR UNLESS SPECIFICALLY INCLUDED IN PURCHASE ORDER. (SEE MEP DRAWINGS FOR LOCATION)DEMANDAIRE RESET RELAY STAINLESS STEEL SCREEN #40 MESH GAS PIPE & FLANGED PIPE FITTINGS NOT BY STREIVOR REMOVABLE DRAIN PLUG ASME B16.5 FLANGED ENDS JUNCTION BOX FROM DEMANDAIRE CONTROL PANEL 120V / 15A MAX ELECTRICAL CONNECTION(S) FIELD WIRED BY OTHERS ·REFER TO DEMANDAIRE DRAWINGS FOR MORE INFORMATION AND LOCATION FROM ELECTRICAL SWITCH COM NO DEMANDAIRE CONTROL PANELNC TO NORMALLY OPEN SHUNT DEVICE NH TO ELECTRIC GAS VALVE(S) (UP TO 3 IN PARALLEL) DEMANDAIRE POWER IN FROM CIRCUIT BREAKER (120 VAC / 20A MAX) H/N/GND H1 N1 H1/N1/GND ELECTRIC GAS VALVE POWER IN FROM CIRCUIT BREAKER (120 VAC / 15A MAX) TYPICAL JUNCTION BOX (NOT PROVIDED BY STREIVOR) TO DEMANDAIRE CONTROL PANEL FUSIBLE LINK CONNECTION ELECTRICAL CONNECTIONS TO BE MADE OUTSIDE OF CONTROL HEAD FIELD WIRING BY OTHERS 115 1 111, 112, & 113 12/02/2021 KSK KCS THE MARSHALL ASSOCIATES SILVER ROCK - CONFERENCE CENTER 79-179 AHMANSON LANE LA QUINTA, CA 92253 TRIMARK ORANGE COUNTY SYSTEM #1 - HOOD #112 SYSTEM #1 - HOOD #111 150 114 123 3512 351 2 36 36 5512 5 22 58 1212 1212 201 2 1512 1512 412 42 15 24 24 24 91 2 3 DUCTPLENUMAPPLIANCEZONE COVERAGE CYLINDER #2 COVERAGE DESCRIPTION NOZZLE FLOW POINTSQTY.PAGE TOTAL FLOW POINTS PIPING LIMITATIONS MAXIMUM ALLOTTED CYLINDER FLOW POINTS TOTAL FIRST TO LAST NOZZZLE LENGTH*VOLUME LENGTH*VOLUME FT ML FT ML PCL-460 14 90.67 3400 80.00 3000 FT ML FT ML1463.00 2363 38.00 1425 14 DUCTPLENUMAPPLIANCEZONE COVERAGE CYLINDER #3 COVERAGE DESCRIPTION NOZZLE FLOW POINTSQTY.PAGE TOTAL FLOW POINTS PIPING LIMITATIONS MAXIMUM ALLOTTED CYLINDER FLOW POINTS TOTAL FIRST TO LAST NOZZZLE LENGTH*VOLUME LENGTH*VOLUME FT ML FT ML PCL-460 14 90.67 3400 80.00 3000 FT ML FT ML1064.00 2400 29.00 1088 10 RANGE 2 L 2 4 3-7 PLENUM 1 H 2 2 3-3 DUCT 2 D 2 4 3-1 GRIDDLE 2 H 2 4 3-10 FRYER 2 H 1 2 3-5 BROILER 1 H 2 2 3-11 PLENUM 1 H 2 2 3-3 DUCT 2 D 2 4 3-1 FRYER 2 H 2 4 3-5 TILT SKILLET 2 H 3 6 3-14 PLENUM 1 H 1 1 3-3 DUCT 2 D 1 2 3-1 SYSTEM #1 * CALCULATIONS BASED ON 3/8" PIPE (37.5 ML/FT) (SEE pg. 3-18) **ML STYLE FUSIBLE LINK INCLUDED WITH SYSTEM (NOT SUPPLIED BY STREIVOR). FUSIBLE LINK TEMPERATURE RATING TO BE VERIFIED AND DETERMINED IN FIELD. PAGE NUMBERS REFERENCED FROM THE PYROCHEM FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL LENGTH PULLEYS BRACKETS FUSIBLE LINK (pg. 4-5) MAXIMUM 150.00 FT 40 20 ALLOTTED 65.00 FT 12 13 ** PULL STATION(S) (pg. 4-9) MAXIMUM 150.00 FT 40 N/A ALLOTTED 70.00 FT 2 N/A GAS VALVE(S) (pg. 4-10) MAXIMUM 100.00 FT 30 N/A ALLOTTED --.--FT --N/A CABLE/LINE LIMITATIONS - CONTROL HEAD 1 : 113 1 : 112 1 : 111 1 : 183 PSK PS K 1 : 182 12 66 NOTES TO ARCHITECT AND/OR CONTRACTOR: STREIVOR, INC. (STREIVOR AIR SYSTEMS, STREIVOR STAINLESS) IS A SPECIALIST IN THE LAYOUT AND DESIGN OF KITCHEN VENTILATION SYSTEMS, AND IN NO WAY PURPORTS TO BE ARCHITECTS OR ENGINEERS. THIS PLAN IS SUBMITTED FOR THE CONVENIENCE OF THE ARCHITECT AND/OR CONTRACTOR AND IS DONE FROM AVAILABLE ARCHITECTURAL INFORMATION. ALL MEASUREMENTS ARE SUBJECT TO PHYSICAL VERIFICATION AND ANY DEVIATIONS OR DISCREPANCIES SHALL BE DIRECTED TO THE ATTENTION OF STREIVOR, INC. IN WRITING. STREIVOR, INC. ACCEPTS NO RESPONSIBILITY FOR WORK DONE BY SAID ARCHITECT OR GENERAL CONTRACTOR OR THEIR REPRESENTATIVES OR SUBCONTRACTORS, AND WILL NOT STAND ANY EXPENSE FOR CHANGES MADE NECESSARY DUE TO LOCAL BUILDING CODES, ORDINANCES, STRUCTURAL CONDITIONS, OR BY ANY SUBSTITUTIONS OR CHANGES IN EQUIPMENT SHOWN ON THIS PLAN. ANY ERRORS, AMBIGUITIES OR OMISSIONS IN THIS PLAN OR SPECIFICATIONS SHALL BE REPORTED TO STREIVOR, INC. FOR CORRECTIONS BEFORE ANY OF THE WORK IS STARTED. UNLESS EXPRESSLY STIPULATED, NO ADDITIONAL ALLOWANCE WILL BE MADE IN FAVOR OF THE OWNER OR CONTRACTOR. BY VIRTUE OF ERROR, AMBIGUITY OR OMISSION WHICH SHOULD HAVE BEEN DISCOVERED DURING THE PREPARATION OF BID ESTIMATES, AND DIRECTED TO THE ATTENTION OF STREIVOR, INC. IN A TIMELY MANNER. GENERAL NOTES: INSTALLER: DESCRIPTION DATE INT DATE: SCALE: DRAWN BY: CHECKED BY: CONSULTANT: 1/2" = 1' - 0" HOOD #: IF BAR DOES NOT MEASURE 1" THIS DRAWING IS NOT PLOTTED TO SCALE (UNLESS OTHERWISE NOTED) SYSTEM #: ITEM #: ------/--/----- ------/--/----- ------/--/----- ------/--/----- ------/--/----- 115 1 111, 112, & 113 12/02/2021 KSK KCS THE MARSHALL ASSOCIATES --- --- --- --- DRAWING: F-02 SHEET OF02 03 HIGH BACK SHELVES YES NO PULL STATION LOCATION(S)YES NO UTILITY CABINET LOCATION(S)YES NO YES NO AGENT DISTRIBUTION HOSE AND RESTRAINING CABLE KIT RANGE COOKING SURFACE DEPTH GREATER THAN 28" YES NO COOKING EQUIPMENT VERIFICATION CEILING HEIGHT ' - " NOTE TO REVIEWER: ANY CHANGES IN COOKING EQUIPMENT SUCH AS EQUIPMENT POSITION, TYPE AND/OR INCREASE IN ENERGY OUTPUT MAY EFFECT EXHAUST AIRFLOW. STREIVOR AIR SYSTEMS MUST BE NOTIFIED OF ANY CHANGES THAT OCCUR PRIOR TO FABRICATION, A RE-ENGINEERING OF THE EXHAUST AIRFLOW MAY BE REQUIRED. ADDITIONAL SITE VISIT FOR FIRE SUPPRESSION PRE-TEST IS NOT INCLUDED UNLESS SPECIFICALLY LISTED IN QUOTE. CUSTOMER APPROVAL VERIFY THE FOLLOWING: _____________________________________ APPROVED BY DATE2150 KITTY HAWK ROAD, LIVERMORE, CA 94551PHONE: (925) 960-9090 FAX:(925) 960-9055WWW.STREIVOR.COM COPYRIGHT © 2021 STREIVOR, INC. PROJECT: SILVER ROCK - CONFERENCE CENTER 79-179 AHMANSON LANE LA QUINTA, CA 92253 TRIMARK ORANGE COUNTY INSTALLATION REQUIREMENTS 1.ALL PIPE SHALL BE SCHEDULE 40 BLACK IRON. CHROME PLATED/SLEEVED WHERE EXPOSED. 2.ALL CYLINDER SYSTEMS SHALL HAVE 3/8" SUPPLY LINES AND 3/8" BRANCH LINES. 3.ALL WIRE ROPE SHALL BE 1/16" STAINLESS STEEL AND RUN THROUGH 1/2" EMT CONDUIT. 4.U.L. LISTED CORNER PULLEYS REQUIRED WHENEVER THE STAINLESS STEEL CABLE DIRECTION CHANGES. 5.ALL EQUIPMENT WITH FIRE PROTECTION MUST BE SECURED TO FLOOR. (NOT BY STREIVOR) 6.SWIVEL ADAPTERS MAY BE ADDED TO NOZZLES FOR UP TO 30° ROTATION. R THIS WET CHEMICAL EXTINGUISHING SYSTEM IS ENGINEERED TO PROVIDE FIRE PROTECTION FOR RESTAURANT HOODS, DUCTS AND COOKING APPLIANCES, IS UL 300 LISTED AND IS TO BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS: LISTINGS & STANDARDS N PFAR 300 ·NFPA 17A 2017 EDITION ·NFPA 10 2018 EDITION ·NFPA 96 2017 EDITION SECTIONS & CODES NFPA 10 2018 EDITION (6.6.2) MAXIMUM TRAVEL DISTANCE SHALL NOT EXCEED 30 FT (9.1 M) FROM THE HAZARD TO THE EXTINGUISHER(S) NFPA 17A 2017 EDITION (5.2.1.10.1) EACH MANUAL ACTUATION DEVICE SHALL BE INSTALLED NO MORE THAN 48 IN. (1200 MM) AND NO LESS THAN 42 IN. (1067 MM) ABOVE THE FLOOR. NFPA 96 2017 EDITION (8.2.3.1)A HOOD EXHAUST FAN(S) SHALL CONTINUE TO OPERATE AFTER THE EXTINGUISHING SYSTEM HAS BEEN ACTIVATED UNLESS FAN SHUTDOWN IS REQUIRED BY A LISTED COMPONENT OF THE VENTILATION SYSTEM OR BY THE DESIGN OF THE EXTINGUISHING SYSTEM. (8.2.3.2)THE HOOD EXHAUST FAN SHALL START UPON ACTIVATION OF THE EXTINGUISHING SYSTEM IF THE EXHAUST FAN AND ALL COOKING EQUIPMENT SERVED BY THE FAN HAVE BEEN SHUT DOWN, UNLESS FAN SHUTDOWN IS REQUIRED BY A LISTED COMPONENT OF THE VENTILATION SYSTEM OR BY THE LISTING OF THE EXTINGUISHING SYSTEM. (8.3.2)WHEN THE FIRE-EXTINGUISHING SYSTEM ACTIVATES, MAKEUP AIR SUPPLIED INTERNALLY TO A HOOD SHALL BE SHUT OFF. (10.4.1)UPON ACTIVATION OF ANY FIRE EXTINGUISHING SYSTEM FOR A COOKING OPERATION, ALL SOURCES OF FUEL AND ELECTRICAL POWER THAT PRODUCE HEAT TO ALL EQUIPMENT REQUIRING PROTECTION BY THAT SYSTEM SHALL AUTOMATICALLY SHUT OFF. (10.4.3)ANY GAS APPLIANCE NOT REQUIRING PROTECTION BUT LOCATED UNDER VENTILATING EQUIPMENT WHERE PROTECTED APPLIANCES ARE LOCATED SHALL BE AUTOMATICALLY SHUT OFF UPON ACTIVATION OF THE EXTINGUISHING SYSTEM (10.4.4)SHUTOFF DEVICE SHALL REQUIRE MANUAL RESET. (10.5.1.1)AT LEAST ONE MANUAL ACTUATION DEVICE SHALL BE LOCATED IN A MEANS OF EGRESS OR AT A LOCATION ACCEPTABLE TO THE AHJ. (10.5.1.2)THE MANUAL ACTUATION DEVICE SHALL CLEARLY IDENTIFY THE HAZARD PROTECTED. CMC 2018 EDITION (513.5) MANUAL ACTIVATION SHALL BE ACCESSIBLE IN THE EVENT OF A FIRE. NOT LESS THAN ONE MANUAL ACTUATION DEVICE SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) AND NOT MORE THAN 20 FEET (6096 MM) FROM THE PROTECTED EXHAUST SYSTEM(S). [IBC 2018: 904.12.1] SYSTEM # : HOOD # NOTE: FIELD PIPING TO BE INSTALLED BY A STREIVOR APPOINTED FIRE INSTALLER FIRE SUPPRESSION SYSTEM CABINET PCL-160 34 LBS CYLINDER WEIGHT PCL-300 53 LBS PCL-460 83 LBS ·36" MINIMUM CLEARANCE REQURIED IN FRONT OF THE REMOVABLE CABINET DOOR. ·SUPPORT BACKING REQUIRED IF CABINET MOUNTS TO WALL ·CABINET AND FIRE SUPPRESSION SYSTEM COMPONENTS APPROXIMATELY 100 LBS/FT. SEE PATH OF EGRESS DRAWING FOR CABINET DIMENSIONS) PATH OF EGRESS SCALE: ISOMETRIC APPLIANCE LAYOUT SCALE:N.T.S. 1"x1"x1 8" ANGLE IRON TO BE SCREWED TO WALL BACKING NMCH3 1/4" = 1'-0" LEGEND 24 APPLIANCE NOZZLE AND HEIGHT CONTROL HEAD DETECTOR BRACKET (FRONT VIEW) DETECTOR BRACKET (PLAN VIEW) DOWNWARD FACING NOZZLE ANGLED NOZZLE AND TARGET LOCATION PULL STATION NOZZLE COVERAGE K-CLASS FIRE EXTINGUISHER (NOT SUPPLIED BY STREIVOR) PIPING FIELD PIPING PATH OF EGRESS PAC-10 PNEUMATIC TUBING DETECTION LINE ROUTE 48 1H 1X 1X 120 1H PLENUM NOZZLE MAX PLENUM LENGTH DUCT NOZZLE MAX PERIMETER100 2D PS K GAS VALVEGV RESET RELAYRR FIELD WIRING NOT BY STRIEVOR TO ACTIVATE FIRE SUPPRESSION SYSTEM PULL STATION IN CASE OF FIRE PULL 4x4 J-BOX TO BE RECESSED OR SURFACE MOUNT "D" RING PULL HANDLE RED PLASTIC BREAK ROD ALUMINUM FACE PLATE (PART # 551074) FINISHED CEILING 12" E.M.T. CONDUIT (RECESSED) 42"-48" A.F.F. STUBBED MIN. 6" ABOVE FINISHED CEILING FINISHED FLOOR CORNER PULLEY PROVIDED BY FIRE SUPPRESSION INSTALLER 2" CL NMCH3 CONTROL HEAD PULL STATION CONNECTION N.C.N.O.COMLOW VOLTAGE ALARM SWITCH WIRING ·EXCEPT FOR ALARM INITIATING SWITCH, NO ELECTRICAL CONNECTIONS ARE TO BE MADE INSIDE THE CONTROL HEAD ENCLOSURE. (PART # 551203) ELECTRICAL SWITCHES SPARE ELECTRICAL SWITCH TO DEMANDAIRE CONTROL PANEL TO BUILDING ALARM ELECTRICAL SWITCH WIRING ·REFER TO NFPA 96 CODES 8.3.2 & 10.4.1 FOR MORE INFORMATION ·SHUNT DEVICE TO BE NORMALLY OPEN (NOT PROVIDED BY STREIVOR) ·EXCEPT FOR ALARM INITIATING SWITCH, NO ELECTRICAL CONNECTIONS ARE TO BE MADE INSIDE THE CONTROL HEAD ENCLOSURE. SPARE ELECTRICAL SWITCH ALARM SWITCH N.C. N.O. COM NORMALLY OPEN (BLACK) COMMON (RED) NORMALLY CLOSED (BROWN) ACTUATING ARM ·QUANTITY: 1 ·SWITCH IS RATED AT 28 VDC, 50 mA ·FIRE SUPPRESSION SYSTEM TO BE FIELD WIRED INTO BUILDING FIRE ALARM SYSTEM (BY OTHERS). (PART # 550077) N.C. N.O. COM ACTUATING ARM PRESS CONNECTOR TIGHTLY AGAINST SWITCH COMMON (RED) NORMALLY OPEN (BLACK) NORMALLY CLOSED (BROWN) ·QUANITITY: 3 ·SWITCH IS RATED AT 250 VAC, 21A RESISTIVE; 250 VAC, 2 HP; 125 VAC, 1 HP ELECTRICAL SWITCH (PART # 551154) SECTION A-A A A GV ·GAS SHUT-OFF VALVE(S) TO BE SIZED AND LOCATED PER MEP DRAWINGS (MAXIMUM VALVE SIZE: 3" NPT) ·REFER TO ELECTRIC GAS SHUT-OFF VALVE & FLANGED Y-STRAINER DETAIL ·MUST BE ACCESSIBLE ELECTRIC GAS SHUT-OFF VALVE & FLANGED Y-STRAINER ·GAS SHUT-OFF VALVE(S) TO BE SIZED AND LOCATED PER MEP DRAWINGS (MAXIMUM VALVE SIZE: 3" NPT) ·VALVE(S) AND STRAINERS TO BE INSTALLED BY DIVISION 22 (PLUMBING) ·EACH VALVE REQUIRES SEPARATE 120VAC/1, 15A CIRCUIT ·ACTIVATION OF THE FIRE EXTINGUISHING SYSTEM WILL SHUT OFF THE VALVE PREVENTING GAS FLOW AND WILL REMAIN CLOSED UNTIL THE RESET RELAY IS MANUALLY PRESSED. ·Y-STRAINER REQUIRED FOR THE PROTECTION OF THE GAS VALVE. INSTALL A Y-STRAINER ON THE INLET SIDE OF THE GAS VALVE (AS CLOSE AS POSSIBLE). Y-STRAINER NOT PROVIDED BY STREIVOR UNLESS SPECIFICALLY INCLUDED IN PURCHASE ORDER. (SEE MEP DRAWINGS FOR LOCATION)DEMANDAIRE RESET RELAY STAINLESS STEEL SCREEN #40 MESH GAS PIPE & FLANGED PIPE FITTINGS NOT BY STREIVOR REMOVABLE DRAIN PLUG ASME B16.5 FLANGED ENDS JUNCTION BOX FROM DEMANDAIRE CONTROL PANEL 120V / 15A MAX ELECTRICAL CONNECTION(S) FIELD WIRED BY OTHERS ·REFER TO DEMANDAIRE DRAWINGS FOR MORE INFORMATION AND LOCATION FROM ELECTRICAL SWITCH COM NO DEMANDAIRE CONTROL PANELNC TO NORMALLY OPEN SHUNT DEVICE NH TO ELECTRIC GAS VALVE(S) (UP TO 3 IN PARALLEL) DEMANDAIRE POWER IN FROM CIRCUIT BREAKER (120 VAC / 20A MAX) H/N/GND H1 N1 H1/N1/GND ELECTRIC GAS VALVE POWER IN FROM CIRCUIT BREAKER (120 VAC / 15A MAX) TYPICAL JUNCTION BOX (NOT PROVIDED BY STREIVOR) TO DEMANDAIRE CONTROL PANEL FUSIBLE LINK CONNECTION ELECTRICAL CONNECTIONS TO BE MADE OUTSIDE OF CONTROL HEAD FIELD WIRING BY OTHERS CONTROL HEAD ·SEE NMCH3 CONTROL HEAD DETAIL FOR MORE INFORMATION ·SEE FIRE SUPPRESSION SYSTEM CABINET DETAIL FOR MORE INFORMATIONDUCTPLENUMAPPLIANCEZONE COVERAGE CYLINDER #1 COVERAGE DESCRIPTION NOZZLE FLOW POINTSQTY.PAGE TOTAL FLOW POINTS PIPING LIMITATIONS MAXIMUM ALLOTTED CYLINDER FLOW POINTS TOTAL FIRST TO LAST NOZZZLE LENGTH*VOLUME LENGTH*VOLUME FT ML FT ML PCL-460 14 90.67 3400 80.00 3000 FT ML FT ML1345.00 1688 32.00 1200 13 DUCTPLENUMAPPLIANCEZONE COVERAGE CYLINDER #2 COVERAGE DESCRIPTION NOZZLE FLOW POINTSQTY.PAGE TOTAL FLOW POINTS PIPING LIMITATIONS MAXIMUM ALLOTTED CYLINDER FLOW POINTS TOTAL FIRST TO LAST NOZZZLE LENGTH*VOLUME LENGTH*VOLUME FT ML FT ML PCL-460 14 90.67 3400 80.00 3000 FT ML FT ML1463.00 2363 38.00 1425 14 DUCTPLENUMAPPLIANCEZONE COVERAGE CYLINDER #3 COVERAGE DESCRIPTION NOZZLE FLOW POINTSQTY.PAGE TOTAL FLOW POINTS PIPING LIMITATIONS MAXIMUM ALLOTTED CYLINDER FLOW POINTS TOTAL FIRST TO LAST NOZZZLE LENGTH*VOLUME LENGTH*VOLUME FT ML FT ML PCL-460 14 90.67 3400 80.00 3000 FT ML FT ML1064.00 2400 29.00 1088 10 RANGE 2 L 2 4 3-7 PLENUM 1 H 2 2 3-3 DUCT 2 D 2 4 3-1 GRIDDLE 2 H 2 4 3-10 FRYER 2 H 1 2 3-5 BROILER 1 H 2 2 3-11 PLENUM 1 H 2 2 3-3 DUCT 2 D 2 4 3-1 FRYER 2 H 2 4 3-5 TILT SKILLET 2 H 3 6 3-14 PLENUM 1 H 1 1 3-3 DUCT 2 D 1 2 3-1 SYSTEM #1 * CALCULATIONS BASED ON 3/8" PIPE (37.5 ML/FT) (SEE pg. 3-18) **ML STYLE FUSIBLE LINK INCLUDED WITH SYSTEM (NOT SUPPLIED BY STREIVOR). FUSIBLE LINK TEMPERATURE RATING TO BE VERIFIED AND DETERMINED IN FIELD. PAGE NUMBERS REFERENCED FROM THE PYROCHEM FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL LENGTH PULLEYS BRACKETS FUSIBLE LINK (pg. 4-5) MAXIMUM 150.00 FT 40 20 ALLOTTED 65.00 FT 12 13 ** PULL STATION(S) (pg. 4-9) MAXIMUM 150.00 FT 40 N/A ALLOTTED 70.00 FT 2 N/A GAS VALVE(S) (pg. 4-10) MAXIMUM 100.00 FT 30 N/A ALLOTTED --.--FT --N/A CABLE/LINE LIMITATIONS - CONTROL HEAD DUCT NOZZLE COVERAGE 2D: 100" PERIMETER 2D 16 10 1H PLENUM NOZZLE COVERAGE 1H: 120 LONG x 48 WIDE 111 x 18 1H PLENUM NOZZLE COVERAGE 1H: 120 LONG x 48 WIDE 2D DUCT NOZZLE COVERAGE Ø10 2D: 37" DIAMETER 55 1412 1412 12 1H 1H 2L 2L 24 MAX COVERAGE: BAXTER OVEN (ALL FIELD PIPING) 1H: 28x12 RANGE 2L: 28x28 OVEN 1 : 113 1 : 112 1 : 111 1 : 183 K PS K 1 : 182 12 66 NOTES TO ARCHITECT AND/OR CONTRACTOR: STREIVOR, INC. (STREIVOR AIR SYSTEMS, STREIVOR STAINLESS) IS A SPECIALIST IN THE LAYOUT AND DESIGN OF KITCHEN VENTILATION SYSTEMS, AND IN NO WAY PURPORTS TO BE ARCHITECTS OR ENGINEERS. THIS PLAN IS SUBMITTED FOR THE CONVENIENCE OF THE ARCHITECT AND/OR CONTRACTOR AND IS DONE FROM AVAILABLE ARCHITECTURAL INFORMATION. ALL MEASUREMENTS ARE SUBJECT TO PHYSICAL VERIFICATION AND ANY DEVIATIONS OR DISCREPANCIES SHALL BE DIRECTED TO THE ATTENTION OF STREIVOR, INC. IN WRITING. STREIVOR, INC. ACCEPTS NO RESPONSIBILITY FOR WORK DONE BY SAID ARCHITECT OR GENERAL CONTRACTOR OR THEIR REPRESENTATIVES OR SUBCONTRACTORS, AND WILL NOT STAND ANY EXPENSE FOR CHANGES MADE NECESSARY DUE TO LOCAL BUILDING CODES, ORDINANCES, STRUCTURAL CONDITIONS, OR BY ANY SUBSTITUTIONS OR CHANGES IN EQUIPMENT SHOWN ON THIS PLAN. ANY ERRORS, AMBIGUITIES OR OMISSIONS IN THIS PLAN OR SPECIFICATIONS SHALL BE REPORTED TO STREIVOR, INC. FOR CORRECTIONS BEFORE ANY OF THE WORK IS STARTED. UNLESS EXPRESSLY STIPULATED, NO ADDITIONAL ALLOWANCE WILL BE MADE IN FAVOR OF THE OWNER OR CONTRACTOR. BY VIRTUE OF ERROR, AMBIGUITY OR OMISSION WHICH SHOULD HAVE BEEN DISCOVERED DURING THE PREPARATION OF BID ESTIMATES, AND DIRECTED TO THE ATTENTION OF STREIVOR, INC. IN A TIMELY MANNER. GENERAL NOTES: SYSTEM #1 - HOOD #183 INSTALLER: DESCRIPTION DATE INT DATE: SCALE: DRAWN BY: CHECKED BY: CONSULTANT: 1/2" = 1' - 0" HOOD #: IF BAR DOES NOT MEASURE 1" THIS DRAWING IS NOT PLOTTED TO SCALE (UNLESS OTHERWISE NOTED) SYSTEM #: 111 ITEM #: CYLINDER #4 FROM WALL MOUNTED UTILITY CABINET ------/--/----- ------/--/----- ------/--/----- ------/--/----- ------/--/----- --- --- --- --- DRAWING: F-03 SHEET OF03 03 HIGH BACK SHELVES YES NO PULL STATION LOCATION(S)YES NO UTILITY CABINET LOCATION(S)YES NO YES NO AGENT DISTRIBUTION HOSE AND RESTRAINING CABLE KIT RANGE COOKING SURFACE DEPTH GREATER THAN 28" YES NO COOKING EQUIPMENT VERIFICATION CEILING HEIGHT ' - " NOTE TO REVIEWER: ANY CHANGES IN COOKING EQUIPMENT SUCH AS EQUIPMENT POSITION, TYPE AND/OR INCREASE IN ENERGY OUTPUT MAY EFFECT EXHAUST AIRFLOW. STREIVOR AIR SYSTEMS MUST BE NOTIFIED OF ANY CHANGES THAT OCCUR PRIOR TO FABRICATION, A RE-ENGINEERING OF THE EXHAUST AIRFLOW MAY BE REQUIRED. ADDITIONAL SITE VISIT FOR FIRE SUPPRESSION PRE-TEST IS NOT INCLUDED UNLESS SPECIFICALLY LISTED IN QUOTE. CUSTOMER APPROVAL VERIFY THE FOLLOWING: _____________________________________ APPROVED BY DATE2150 KITTY HAWK ROAD, LIVERMORE, CA 94551PHONE: (925) 960-9090 FAX:(925) 960-9055WWW.STREIVOR.COM COPYRIGHT © 2021 STREIVOR, INC. PROJECT: INSTALLATION REQUIREMENTS 1.ALL PIPE SHALL BE SCHEDULE 40 BLACK IRON. CHROME PLATED/SLEEVED WHERE EXPOSED. 2.ALL CYLINDER SYSTEMS SHALL HAVE 3/8" SUPPLY LINES AND 3/8" BRANCH LINES. 3.ALL WIRE ROPE SHALL BE 1/16" STAINLESS STEEL AND RUN THROUGH 1/2" EMT CONDUIT. 4.U.L. LISTED CORNER PULLEYS REQUIRED WHENEVER THE STAINLESS STEEL CABLE DIRECTION CHANGES. 5.ALL EQUIPMENT WITH FIRE PROTECTION MUST BE SECURED TO FLOOR. (NOT BY STREIVOR) 6.SWIVEL ADAPTERS MAY BE ADDED TO NOZZLES FOR UP TO 30° ROTATION. R THIS WET CHEMICAL EXTINGUISHING SYSTEM IS ENGINEERED TO PROVIDE FIRE PROTECTION FOR RESTAURANT HOODS, DUCTS AND COOKING APPLIANCES, IS UL 300 LISTED AND IS TO BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS: LISTINGS & STANDARDS N PFAR 300 ·NFPA 17A 2017 EDITION ·NFPA 10 2018 EDITION ·NFPA 96 2017 EDITION SECTIONS & CODES NFPA 10 2018 EDITION (6.6.2) MAXIMUM TRAVEL DISTANCE SHALL NOT EXCEED 30 FT (9.1 M) FROM THE HAZARD TO THE EXTINGUISHER(S) NFPA 17A 2017 EDITION (5.2.1.10.1) EACH MANUAL ACTUATION DEVICE SHALL BE INSTALLED NO MORE THAN 48 IN. (1200 MM) AND NO LESS THAN 42 IN. (1067 MM) ABOVE THE FLOOR. NFPA 96 2017 EDITION (8.2.3.1)A HOOD EXHAUST FAN(S) SHALL CONTINUE TO OPERATE AFTER THE EXTINGUISHING SYSTEM HAS BEEN ACTIVATED UNLESS FAN SHUTDOWN IS REQUIRED BY A LISTED COMPONENT OF THE VENTILATION SYSTEM OR BY THE DESIGN OF THE EXTINGUISHING SYSTEM. (8.2.3.2)THE HOOD EXHAUST FAN SHALL START UPON ACTIVATION OF THE EXTINGUISHING SYSTEM IF THE EXHAUST FAN AND ALL COOKING EQUIPMENT SERVED BY THE FAN HAVE BEEN SHUT DOWN, UNLESS FAN SHUTDOWN IS REQUIRED BY A LISTED COMPONENT OF THE VENTILATION SYSTEM OR BY THE LISTING OF THE EXTINGUISHING SYSTEM. (8.3.2)WHEN THE FIRE-EXTINGUISHING SYSTEM ACTIVATES, MAKEUP AIR SUPPLIED INTERNALLY TO A HOOD SHALL BE SHUT OFF. (10.4.1)UPON ACTIVATION OF ANY FIRE EXTINGUISHING SYSTEM FOR A COOKING OPERATION, ALL SOURCES OF FUEL AND ELECTRICAL POWER THAT PRODUCE HEAT TO ALL EQUIPMENT REQUIRING PROTECTION BY THAT SYSTEM SHALL AUTOMATICALLY SHUT OFF. (10.4.3)ANY GAS APPLIANCE NOT REQUIRING PROTECTION BUT LOCATED UNDER VENTILATING EQUIPMENT WHERE PROTECTED APPLIANCES ARE LOCATED SHALL BE AUTOMATICALLY SHUT OFF UPON ACTIVATION OF THE EXTINGUISHING SYSTEM (10.4.4)SHUTOFF DEVICE SHALL REQUIRE MANUAL RESET. (10.5.1.1)AT LEAST ONE MANUAL ACTUATION DEVICE SHALL BE LOCATED IN A MEANS OF EGRESS OR AT A LOCATION ACCEPTABLE TO THE AHJ. (10.5.1.2)THE MANUAL ACTUATION DEVICE SHALL CLEARLY IDENTIFY THE HAZARD PROTECTED. CMC 2018 EDITION (513.5) MANUAL ACTIVATION SHALL BE ACCESSIBLE IN THE EVENT OF A FIRE. NOT LESS THAN ONE MANUAL ACTUATION DEVICE SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) AND NOT MORE THAN 20 FEET (6096 MM) FROM THE PROTECTED EXHAUST SYSTEM(S). [IBC 2018: 904.12.1] SYSTEM #1 * CALCULATIONS BASED ON 3/8" PIPE (37.5 ML/FT) (SEE pg. 3-18) **ML STYLE FUSIBLE LINK INCLUDED WITH SYSTEM (NOT SUPPLIED BY STREIVOR). FUSIBLE LINK TEMPERATURE RATING TO BE VERIFIED AND DETERMINED IN FIELD. PAGE NUMBERS REFERENCED FROM THE PYROCHEM FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL LENGTH PULLEYS BRACKETS FUSIBLE LINK (pg. 4-5) MAXIMUM 150.00 FT 40 20 ALLOTTED 65.00 FT 12 13 ** PULL STATION(S) (pg. 4-9) MAXIMUM 150.00 FT 40 N/A ALLOTTED 70.00 FT 2 N/A GAS VALVE(S) (pg. 4-10) MAXIMUM 100.00 FT 30 N/A ALLOTTED --.--FT --N/A CABLE/LINE LIMITATIONS - CONTROL HEAD SYSTEM # : HOOD #DUCTPLENUMAPPLIANCEZONE COVERAGE CYLINDER #4 COVERAGE DESCRIPTION NOZZLE FLOW POINTSQTY.PAGE TOTAL FLOW POINTS PIPING LIMITATIONS MAXIMUM ALLOTTED CYLINDER FLOW POINTS TOTAL FIRST TO LAST NOZZZLE LENGTH*VOLUME LENGTH*VOLUME FT ML FT ML PCL-460 14 90.67 3400 80.00 3000 FT ML FT ML1246.00 1725 35.00 1313 12 DUCT 2 D 2 4 3-1 PLENUM 1 H 2 2 3-3 RANGE 2 L 2 4 3-7 RANGE 1 H 2 2 3-6 NOTE: FIELD PIPING TO BE INSTALLED BY A STREIVOR APPOINTED FIRE INSTALLER FIRE SUPPRESSION SYSTEM CABINET PCL-160 34 LBS CYLINDER WEIGHT PCL-300 53 LBS PCL-460 83 LBS ·36" MINIMUM CLEARANCE REQURIED IN FRONT OF THE REMOVABLE CABINET DOOR. ·SUPPORT BACKING REQUIRED IF CABINET MOUNTS TO WALL ·CABINET AND FIRE SUPPRESSION SYSTEM COMPONENTS APPROXIMATELY 100 LBS/FT. SEE PATH OF EGRESS DRAWING FOR CABINET DIMENSIONS) PATH OF EGRESS SCALE: ISOMETRIC APPLIANCE LAYOUT SCALE:N.T.S. 1"x1"x1 8" ANGLE IRON TO BE SCREWED TO WALL BACKING NMCH3 3/16" = 1'-0" LEGEND 24 APPLIANCE NOZZLE AND HEIGHT CONTROL HEAD DETECTOR BRACKET (FRONT VIEW) DETECTOR BRACKET (PLAN VIEW) DOWNWARD FACING NOZZLE ANGLED NOZZLE AND TARGET LOCATION PULL STATION NOZZLE COVERAGE K-CLASS FIRE EXTINGUISHER (NOT SUPPLIED BY STREIVOR) PIPING FIELD PIPING PATH OF EGRESS PAC-10 PNEUMATIC TUBING DETECTION LINE ROUTE 48 1H 1X 1X 120 1H PLENUM NOZZLE MAX PLENUM LENGTH DUCT NOZZLE MAX PERIMETER100 2D PS K GAS VALVEGV RESET RELAYRR FIELD WIRING NOT BY STRIEVOR TO ACTIVATE FIRE SUPPRESSION SYSTEM PULL STATION IN CASE OF FIRE PULL 4x4 J-BOX TO BE RECESSED OR SURFACE MOUNT "D" RING PULL HANDLE RED PLASTIC BREAK ROD ALUMINUM FACE PLATE (PART # 551074) FINISHED CEILING 12" E.M.T. CONDUIT (RECESSED) 42"-48" A.F.F. STUBBED MIN. 6" ABOVE FINISHED CEILING FINISHED FLOOR CORNER PULLEY PROVIDED BY FIRE SUPPRESSION INSTALLER 2" CL NMCH3 CONTROL HEAD PULL STATION CONNECTION N.C.N.O.COMLOW VOLTAGE ALARM SWITCH WIRING ·EXCEPT FOR ALARM INITIATING SWITCH, NO ELECTRICAL CONNECTIONS ARE TO BE MADE INSIDE THE CONTROL HEAD ENCLOSURE. (PART # 551203) ELECTRICAL SWITCHES SPARE ELECTRICAL SWITCH TO DEMANDAIRE CONTROL PANEL TO BUILDING ALARM ELECTRICAL SWITCH WIRING ·REFER TO NFPA 96 CODES 8.3.2 & 10.4.1 FOR MORE INFORMATION ·SHUNT DEVICE TO BE NORMALLY OPEN (NOT PROVIDED BY STREIVOR) ·EXCEPT FOR ALARM INITIATING SWITCH, NO ELECTRICAL CONNECTIONS ARE TO BE MADE INSIDE THE CONTROL HEAD ENCLOSURE. SPARE ELECTRICAL SWITCH ALARM SWITCH N.C. N.O. COM NORMALLY OPEN (BLACK) COMMON (RED) NORMALLY CLOSED (BROWN) ACTUATING ARM ·QUANTITY: 1 ·SWITCH IS RATED AT 28 VDC, 50 mA ·FIRE SUPPRESSION SYSTEM TO BE FIELD WIRED INTO BUILDING FIRE ALARM SYSTEM (BY OTHERS). (PART # 550077) N.C. N.O. COM ACTUATING ARM PRESS CONNECTOR TIGHTLY AGAINST SWITCH COMMON (RED) NORMALLY OPEN (BLACK) NORMALLY CLOSED (BROWN) ·QUANITITY: 3 ·SWITCH IS RATED AT 250 VAC, 21A RESISTIVE; 250 VAC, 2 HP; 125 VAC, 1 HP ELECTRICAL SWITCH (PART # 551154) SECTION A-A A A GV ·GAS SHUT-OFF VALVE(S) TO BE SIZED AND LOCATED PER MEP DRAWINGS (MAXIMUM VALVE SIZE: 3" NPT) ·REFER TO ELECTRIC GAS SHUT-OFF VALVE & FLANGED Y-STRAINER DETAIL ·MUST BE ACCESSIBLE CONTROL HEAD ·SEE NMCH3 CONTROL HEAD DETAIL FOR MORE INFORMATION ·SEE FIRE SUPPRESSION SYSTEM CABINET DETAIL FOR MORE INFORMATION ELECTRIC GAS SHUT-OFF VALVE & FLANGED Y-STRAINER ·GAS SHUT-OFF VALVE(S) TO BE SIZED AND LOCATED PER MEP DRAWINGS (MAXIMUM VALVE SIZE: 3" NPT) ·VALVE(S) AND STRAINERS TO BE INSTALLED BY DIVISION 22 (PLUMBING) ·EACH VALVE REQUIRES SEPARATE 120VAC/1, 15A CIRCUIT ·ACTIVATION OF THE FIRE EXTINGUISHING SYSTEM WILL SHUT OFF THE VALVE PREVENTING GAS FLOW AND WILL REMAIN CLOSED UNTIL THE RESET RELAY IS MANUALLY PRESSED. ·Y-STRAINER REQUIRED FOR THE PROTECTION OF THE GAS VALVE. INSTALL A Y-STRAINER ON THE INLET SIDE OF THE GAS VALVE (AS CLOSE AS POSSIBLE). Y-STRAINER NOT PROVIDED BY STREIVOR UNLESS SPECIFICALLY INCLUDED IN PURCHASE ORDER. (SEE MEP DRAWINGS FOR LOCATION)DEMANDAIRE RESET RELAY STAINLESS STEEL SCREEN #40 MESH GAS PIPE & FLANGED PIPE FITTINGS NOT BY STREIVOR REMOVABLE DRAIN PLUG ASME B16.5 FLANGED ENDS JUNCTION BOX FROM DEMANDAIRE CONTROL PANEL 120V / 15A MAX ELECTRICAL CONNECTION(S) FIELD WIRED BY OTHERS ·REFER TO DEMANDAIRE DRAWINGS FOR MORE INFORMATION AND LOCATION FROM ELECTRICAL SWITCH COM NO DEMANDAIRE CONTROL PANELNC TO NORMALLY OPEN SHUNT DEVICE NH TO ELECTRIC GAS VALVE(S) (UP TO 3 IN PARALLEL) DEMANDAIRE POWER IN FROM CIRCUIT BREAKER (120 VAC / 20A MAX) H/N/GND H1 N1 H1/N1/GND ELECTRIC GAS VALVE POWER IN FROM CIRCUIT BREAKER (120 VAC / 15A MAX) TYPICAL JUNCTION BOX (NOT PROVIDED BY STREIVOR) TO DEMANDAIRE CONTROL PANEL FUSIBLE LINK CONNECTION ELECTRICAL CONNECTIONS TO BE MADE OUTSIDE OF CONTROL HEAD FIELD WIRING BY OTHERS SYSTEM #1 - HOOD #182 54 19 5 3 60 12 6 6712 18 131 2 115 1 182 & 183 12/03/2021 KCS KSK THE MARSHALL ASSOCIATES SILVER ROCK - CONFERENCE CENTER 79-179 AHMANSON LANE LA QUINTA, CA 92253 TRIMARK ORANGE COUNTY TECHNICAL MANUAL KITCHEN KNIGHT II Restaurant Fire Suppression Manual UL EX3830 ULC EX3830 2014-NOV-10 REV. 06 This manual is intended for use with PYRO-CHEM KITCHEN KNIGHT II Restaurant Fire Suppression Systems. Those who install, operate, recharge, or maintain these fire suppression systems should read this entire manual. Specific responsibilities. Design, installation, recharge, and maintenance of the system must conform to the limitations detailed in this manual and per- formed by an individual who attended a PYRO-CHEM training program and became trained to install, recharge, design, and maintain the PYRO-CHEM system. Fire suppression systems are mechanical devices. They need periodic care. Maintenance is a vital step in the performance of your fire suppression system. As such it must be performed in accordance with NFPA 96 (Standard for the Installation of Equipment for the Removal of Smoke and Grease-Laden Vapors from Commercial Cooking Equipment) and NFPA 17A (Standard on Wet Chemical Extinguishing Systems) by an authorized PYRO-CHEM distributor. To provide maximum assurance that the fire suppression system will operate effec- tively and safely, maintenance must be conducted at six-month intervals, or earlier if the situation dictates. Twelve-year main- tenance must include agent tank hydrostatic testing. PART NO. 551274-06 PYRO-CHEM, KITCHEN KNIGHT, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. UL EX3830 ULC EX3830 REV. 06 2014-NOV-10 ! Indicates a hazardous situation in which a person will expe- rience serious personal injury or death if the situation is not avoided. ! Indicates a hazardous situation in which a person could expe- rience serious personal injury or death if the situation is not avoided. ! Indicates a hazardous situation in which a person could expe- rience minor or moderate personal injury if the situation is not avoided. Addresses practices not related to personal injury, such as a system part malfunctioning, property damage, or system failure. NOTICE Addresses general practices or observations related to system function that are not related to personal injury. UL EX3830 ULC EX3830 2014-NOV-10 REV. 06 PAGE 1 KITCHEN KNIGHT II Restaurant Fire Suppression Manual UL EX3830 ULC EX3830 2014-NOV-10 REV. 06 PAGE 1 Indicates revised information. Indicates change in page sequence. 2014-NOV-10 Complete manual has been reformatted along with several revised pages that contain updated technical information. For clarity, all pages have been changed to Revision 06, regardless of previous revision number. Technical information changes have been noted with a revision indicator (). DATE PAGE REV. NO. DATE PAGE REV. NO. UL EX3830 ULC EX3830 PAGE 2 REV. 06 2014-NOV-10 Indicates revised information. Indicates change in page sequence. DATE PAGE REV. NO. DATE PAGE REV. NO. UL EX3470 ULC EX3470 2014-NOV-10 REV. 06 PAGE TOC-1 INTRODUCTION 1-1 Temperature Limitations 1-1 UL Listing 1-1 ULC Listing 1-1 MEA Approval 1-1 CYLINDERS & VALVE 2-1 WET VALVE REBUILDING EQUIPMENT 2-1 Wet Valve Seal Rebuilding Kit 2-1 Pressure Regulator Assembly 2-2 Pressure Regulator Rebuilding Kit 2-2 Model VT-1 Tool 2-2 CYLINDER BRACKETING 2-2 EXTINGUISHING AGENT 2-2 MCH3 MECHANICAL CONTROL HEAD 2-3 ECH3 ELECTRICAL CONTROL HEAD 2-3 NMCH3 MECHANICAL CONTROL HEAD 2-3 EN-MCU3 ENCLOSURE 2-3 EN-S ENCLOSURE 2-4 16 GRAM CO2 CARTRIDGE 2-4 MB-P2 MOUNTING BRACKET 2-4 PNEUMATIC ACTUATING CYLINDERS 2-4 Model PAC-10 2-4 DETECTION EQUIPMENT 2-5 Model FLK-1 2-5 Model FLK-1A 2-5 Model FLH-1 2-5 A-PC Fusible Links 2-6 Thermal Detectors 2-6 Flexible Conduit 2-6 RPS-M – REMOTE PULL STATION 2-7 “QUIK-SEAL” ADAPTOR 2-7 “COMPRESSION-SEAL” ADAPTOR 2-7 “HOOD SEAL” ADAPTOR ASSEMBLY 2-7 GAS SHUT-OFF VALVES 2-8 GV Shut-off Valve 2-8 EGVSO Gas Shut-off Valve 2-8 CORNER PULLEYS 2-9 SBP-1 Corner Pulley 2-9 CBP-1 Corner Pulley 2-9 WBP-1 Corner Pulley 2-9 TEE PULLEY 2-9 WIRE ROPE 2-9 ELECTRICAL SWITCHES 2-10 SM-120 SOLENOID MONITOR 2-10 PIPE AND FITTINGS 2-10 AGENT DISTRIBUTION HOSE AND 2-11 RESTRAINING CABLE KIT 2-11 STAINLESS STEEL ACTUATION HOSE 2-11 NOZZLES 2-11 RUBBER BLOW-OFF CAPS 2-11 SWIVEL ADAPTOR 2-11 NOZZLE AIMING DEVICE 2-12 HORN/STROBE ASSEMBLY 2-12 COMPONENTS LIST 2-13 GENERAL 3-1 NOZZLE COVERAGE AND PLACEMENT 3-1 Duct Protection 3-1 Modularizing Duct 3-2 Transition Ducts 3-3 Electrostatic Precipitator 3-3 Plenum Protection 3-3 Appliance Protection 3-4 Design Chart 3-4 Fryers 3-5 Range (Small) 3-6 High-Proximity Backshelf 3-7 Range (Large) 3-7 Nozzle Positioning Table 3-7 Small Wok 3-9 Large Wok 3-9 Small Griddle 3-10 Large Griddle 3-10 Radiant/Electric Char-Broiler 3-11 Lava Rock Char-Broiler 3-11 Natural Charcoal Char-Broiler 3-12 Mesquite Char-Broiler 3-12 Salamander Broiler 3-12 Upright/Salamander Broiler 3-13 Chain Broiler 3-13 Tilt Skillet/Braising Pan 3-14 SPECIFIC APPLICATION BY MODEL 3-15 Henny Penny Fryer – Models 690, 691, 692 3-15 Henny Penny Fryer – Models 580, 3-16 581, 582, 590, 591, 592, 680, 682 Nieco Broiler – Model MPB-84 3-17 Nieco Broiler – Model JF94E 3-17 PIPING LIMITATIONS 3-18 General Piping Requirements 3-19 Design Steps 3-19 DETECTOR PLACEMENT 3-23 Exhaust Duct(s) 3-23 Electrostatic Precipitator 3-23 Cooking Appliance(s) 3-24 UL EX3470 ULC EX3470 PAGE TOC-2 REV. 06 2014-NOV-10 GENERAL 4-1 CYLINDER INSTALLATION 4-1 CONTROL HEAD INSTALLATION 4-1 Single Cylinder Installation 4-1 Multiple Cylinder Installation 4-2 DETECTOR INSTALLATION 4-4 Fusible Link Detection 4-4 Fusible Links Without Hangers 4-5 Fusible Links With Link Hangers 4-6 Thermal Detection 4-6 SETTING THE CONTROL HEAD 4-7 MCH3/NMCH3 Control Head 4-7 ECH3 Control Head 4-7 SOLENOID MONITOR INSTALLATION 4-8 In Detection Circuit 4-8 Solenoid Monitor When Used as a 4-8 Reset Relay REMOTE PULL STATION INSTALLATION 4-8 GAS SHUT-OFF VALVE INSTALLATION 4-10 Mechanical Gas Shut-off 4-10 Valve Installation Electrical Gas Shut-off Valve Installation 4-11 PULLEY TEE INSTALLATION 4-11 ELECTRICAL (SNAP-ACTION) SWITCH 4-11 INSTALLATION PIPE AND NOZZLE INSTALLATION 4-12 INSTALLATION INSTRUCTIONS FOR 4-13 CASTERED/MOVEABLE EQUIPMENT USING AGENT DISTRIBUTION HOSE Critical Installation Requirements 4-13 AGENT DISTRIBUTION HOSE INSTALLATION 4-13 General Requirements 4-13 Installation Requirements 4-13 Restraining Cable Installation 4-14 Final Installation Guidelines and 4-15 Checkout Procedures Agent Distribution Hose/Restraining 4-16 Cable Six-Month Maintenance Blank Page 4-17 SYSTEM CHECKOUT AFTER INSTALLATION 4-18 Model MCH3/NMCH3 Mechanical 4-18 Control Head Model ECH3-24/120 Electrical 4-18 Control Head Testing Thermal Detectors 4-18 Testing Remote Pull Station 4-18 Completing System Checkout 4-19 ENCLOSURE INSTALLATION INSTRUCTIONS 4-19 – MODEL EN-MCU3 AND MODEL EN-S Enclosure Mounting 4-19 Fusible Link Detector Installation 4-20 Setting the EN-MCU3 4-20 Remote Pull Station Installation 4-20 Gas Shut-off Valve Installation 4-20 Electrical (Snap-Action) Switch Installation 4-21 Cylinder Installation 4-21 Single Cylinder Installation 4-21 Multiple Cylinder Installation 4-22 System Checkout After Installation 4-22 FLEXIBLE CONDUIT INSTALLATION 4-23 Design Requirements 4-23 Installation Requirements 4-24 Connecting Flexible Conduit to Control 4-24 Head, Electrical Box, Pull Station, or Mechanical Gas Valve Connecting Flexible Conduit to Pulley 4-26 Elbows, Pulley Tees, or Union Fittings Installing Flexible Conduit Through a 4-27 Conduit Offset Flexible Conduit Splicing 4-29 Testing Pull Station/Mechanical Gas Valve 4-31 GENERAL 5-1 SEMI-ANNUAL MAINTENANCE 5-1 ANNUAL MAINTENANCE 5-1 12-YEAR MAINTENANCE 5-2 GENERAL 6-1 SYSTEM CLEANUP 6-1 SYSTEM RECHARGE 6-1 ! ! ! ! ! ! ! ! OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org June 7, 2022 Echo Fire Protection PO Box 862 Glendora, CA 91702 Re: Kitchen Suppression System Plan Review – MONTAGE – CONFERENCE CENTER FS2022-0004 / 52027 SILVERROCK WAY, LA QUINTA, CA 92253 The plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department and are approved with the following conditions: o Operation instructions must be posted in a visible location. o The hood/duct system must be monitored by the fire alarm system if building is currently monitored. o In a pre-engineered system, only listed components from a single manufacturer shall be used. o When hood/duct system is activated, the gas supply, electric supply, and make up air must automatically shut off. The hood exhaust fan shall remain on after system activation. o A “K” rated extinguisher must be mounted in the kitchen area. The “K” rated extinguisher shall not substitute for the required conventional dry chemical extinguishers in the kitchen. The following inspections/tests shall be witnessed by the Fire Department: o System operation checkout and final test to be performed by the installer. Alarm company representative must also be present at the time of hood/duct inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 52027 SILVERROCK WAY PERMIT#: FS2022-0004 DATE ISSUED: 6/7/2022 DESCRIPTION: MONTAGE CONVENTION CENTER CONTRACTOR: ECHO FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.