Loading...
FSEV2021-0002ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT TOWN AND COUNTRY EVENT RENTALS 7725 AIRPORT BUSINESS PARK WAY VAN NUYS CA 91406 (818)908-4211 lminniti@tacer.biz BILL TO TOWN & COUNTRY EVENT RENTAls 7725 Airport business Park Way Van Nuys CA 91406 (818)908-4211 laurent@tacer.biz CONTRACTOR TOWN AND COUNTRY EVENT RENTALS 7725 AIRPORT BUSINESS PARK WAY VAN NUYS CA 91406 (818)908-4211 lminniti@tacer.biz OWNER THE MADISON CLUB 53035 MERIWETHER WY LA QUINTA CA 92253 (818)908-4211 cclark@madisonclubca. com CONDITIONS Description: TEMPORARY TENT & SUBFLOOR Type: FIRE SPECIAL EVENT (WEB)Subtype: Status: FINALED Applied: 12/28/2021 ECON Parcel No: 767871006 Site Address: 53035 MERIWETHER WY LA QUINTA,CA 92253 Approved: 1/10/2022 KHET Subdivision: TR 34969 Block: Lot: 1 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 1/17/2022 KHET Valuation: $30,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Monday, February 27, 2023 10:31:53 AM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSEV2021-0002 BOND INFORMATION INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FIRE FINAL**KHET 1/17/2022 1/17/2022 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 12/28/2021 12/29/2021 12/29/2021 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 12/28/2021 1/13/2022 1/10/2022 APPROVED SEE ATTACHMENTS PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPECIAL EVENT 101-0000-42421 0 $250.00 $250.00 1/12/22 WEB10359 634768451 10 CREDIT AEC913 ECON FIRE SPECIAL EVENT PC 101-0000-42420 0 $167.00 $167.00 1/12/22 WEB10359 634768451 10 CREDIT AEC913 ECON Total Paid for FIRE FEES: $417.00 $417.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 1/12/22 WEB10359 634768451 10 CREDIT AEC913 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 1/12/22 WEB10359 634768451 10 CREDIT AEC913 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$433.00 $433.00 Printed: Monday, February 27, 2023 10:31:53 AM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSEV2021-0002 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/28/2021 Etrakit Contractor 1ST SUBMITTAL SITE PLAN 1 The Madison Club La Quinta Pool Lawn 40x82 v2.pdf 1 DOC 12/28/2021 Etrakit Contractor 1ST SUBMITTAL SITE PLAN 2 Birds Eye View v2.pdf 1 DOC 12/28/2021 Etrakit Contractor 1ST SUBMITTAL APPLICATION LQ Special Event Application v1.pdf 1 DOC 1/6/2022 Etrakit Contractor 1ST SUBMITTAL STRUCTURAL CALCULATIONS UT-CV-4787-21 Madison Club 40x82 Liri Tent Calculations_Signed.pdf 1 DOC 1/6/2022 Etrakit Contractor 1ST SUBMITTAL REGISTERED FLAME Losberger Liri 12mClear Roof Cover Flame Certificate.pdf 1 DOC 1/10/2022 KOHL HETRICK FSEV2021-0002 - COA AND APPROVED DOCUMENTS.pdf FSEV2021-0002 - COA AND APPROVED DOCUMENTS.pdf 1 Printed: Monday, February 27, 2023 10:31:53 AM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSEV2021-0002 CALIFORNIA DEPARTMENT OF FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL REGISTERED FLAME RESISTANT PRODUCT Product: Registration No. DURASKIN FA-53001 12m clear roof cover Product Marketed By: VERSEIDAG INDUTEX GMBH INDUSTRIESTR 56 47803 KREFELD GERMANY This product meets the minimum requirements of flame resistance established by the California State Fire Marshal for products identified in Section 13115, California Health and Safety Code and passes NFPA 701-96. The scope of the approved use of this product is provided in the current edition of the CALIFORNIA APPROVED LIST OF FLAME RETARDANT CHEMICALS AND FABRICS, GENERAL AND LIMITED APPLICATIONS CONCERNS published by the California State Fire Marshal. _________________________________ Deputy State Fire Marshal OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org January 10, 2022 Town & Country Event Rentals 7725 Airport Business Park Way Van Nuys, CA 91406 The Madison Club 53035 Meriwether Way La Quinta, CA 92253 Re: Special Event / Tent / Canopy – Construction and Operational Fire Plan Review – THE MADISON CLUB – CHARITY DINNER FSEV2021-0002 / 53035 MERIWETHER WAY, LA QUINTA, CA 92253 DATE OF EVENT: 1/17/2022 / TIME: 1700-2200 HOURS / ATTENDANCE: ~100 The plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. FIRE LANES/ACCESS [CFC 503] No designated fire lanes, fire hydrants or any other Fire Department appliances shall be blocked or obstructed. Fire lanes shall be clearly identified in an approved manner throughout the event grounds by posting “NO PARKING FIRE LANE” or other approved means. All motor vehicles shall be parked in designated parking areas. GENERATORS AND INTERNAL COMBUSTION POWER SOURCES Generators (and/or internal combustion power sources) shall be separated from temporary membrane structures, tents, canopies by a minimum of 20 feet and be isolated from contact with the public [CFC 3107.16]. Additional fuel containers will not be allowed to be stored with the generator. Each generator will need to have a 10BC fire extinguisher, with a current service tag (within one year). Combustible material (including trash) shall be kept clear of the generators. EXTENSION CORDS Extension cords shall be over-current protected and/or ground-fault interrupter protected. No additional taps are to be in any device. All extension cords shall be of 12/3 gauge wire or greater with approved connectors. HEATING AND COOKING EQUIPMENT [CFC 3107.12] At least one 2A10BC fire extinguisher, with a current service tag (within one year), shall be provided at all vendor booths that are cooking. One Class K type fire extinguisher, with a current service tag (within one year), shall be provided for each vendor booth with a deep fat fryer. Deep fat fryers shall be located outside tents and protected from the public, unless otherwise directed or approved by The Department of Environmental Health and the Fire Department. All L.P.G. tanks (empty or full) shall be secured with a chain or other approved device to prevent tipping over/unintentional movement and kept a safe distance from open flame. The pressure relief vent should be pointed away from any open flame. COMBUSTIBLE MATERIAL [CFC 3107.19] Accumulation of combustible material (including trash) will be prohibited near any ignition sources within 30-feet of the perimeter of tents and membrane structures. Such waste shall be stored in approved containers and removed from the premises not less than once a day. TENTS AND CANOPY(S) [CFC Chapter 31] Tents over 400 square feet and canopies over 700 square feet shall comply with the following conditions: [1] Extinguishers- At least one 2A10BC fire extinguisher, with a current service tag (within one year), shall be provided within every 75 feet of travel distance. [CFC 3107.9] [2] Exit Signs and Egress Lighting- Tents with side walls shall have illuminated exit signs and means of egress lighting pursuant to CFC Chapter 31 when the tent has an occupant load of 50 or more. [CFC 3103.12.6 & .7] [3] Seating Configuration- Seating configuration needs to comply with CFC Chapter 10 and California Code of Regulations (CCR) Title 19. [4] No Smoking- Smoking shall not be permitted in any tent or canopy or in any adjacent area where hay, sawdust or any other combustible materials are stored. NO SMOKING signs shall be conspicuously posted in all tents and canopies open to the public. [CFC 3107.3] [5] Obstructing exits- Furnishings, decorations or other objects shall not be placed so as to obstruct exits, access thereto, egress therefrom, or visibility thereof. Hangings and draperies shall not be placed over exit doors or otherwise be located to conceal or obstruct an exit. [CFC 3107.20] [6] Decorative Materials- Curtains, draperies, hangings and other decorative materials suspended from walls or ceilings shall meet the flame propagation performance criteria of CCR Title 19 in accordance with section 807.2 or be non-combustible, when the tent has an occupant load of 50 or more. [Ref CFC 807.1] [7] High-Wind Evacuation Plan – The tent supplier and event coordinator shall understand that the use of the tent or canopy in winds at 40 mph or greater is not permitted. Event coordinator is responsible to take necessary actions to stop occupancy and use of the tent or canopy when winds of 40 mph or greater are observed or expected. DESIGNATED SMOKING AREAS [CFC 3106.4.5] Smoking shall be permitted only in designated areas. Other areas shall have approved “No Smoking” signs conspicuously posted and maintained. FIREWORKS/PYRO/FIRE PERFORMERS Fireworks, pyrotechnics or fire performers shall require an additional permit and approval. FIRE INSPECTION Prior to this Special Event, you must be cleared by the Fire Department by way of a Pre-Event Fire Safety Inspection. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: PERMIT#: DATE ISSUED: DESCRIPTION: CONTRACTOR: HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation OUTDOOR PUBLIC EVENT Air flow test SPEC. AMUSEMENT STRUCTURE Mechanical interlock TENT/CANOPY Extinguishing system PYROTECHNIC Fire alarm connection OPEN FLAME DEVICE Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. La Quinta Office of the Fire Marshal 78-495 Calle Tampico La Quinta, CA 92253 760-777-7000 Special Event Application Event Name: Event Contact: Event Address: Contact Phone: City/Zip: Contact Email: Event Date(s): Hours of Operation: Daily Expected/Peak Attendance: Description/Scope of Event: Company Name: Applicant Name: Address: Phone: City/Zip: Email: Food & Beverage: Tents / Canopies:*Tents include any membrane structure with 1 or more sidewall / Canopy = No Sidewall Tents >400 sq ft: Canopies >700 sq ft: Copy of fire retardant certification provided: Display / Vendor Booths: Number of Booths: Cooking in any Booths: Fuel Fire Generator Use:Quantity: Temporary Special Event Structure (Stage, Platform, Rigging, Tower, etc): Special Amusement / Ride Attractions: Description: Open Flame / Pyrotechnics Proposed:*Separate Pyro Permit may be Description: required Parking: Coordinated Parking Management: Planned Emergency/Medical Service Provisions: Level of Service: Planned Traffic Routing Changes / Restrictions: Event / Site Security Proposed: Level of Service: EVENT INFORMATION APPLICANT/SPONSORING ORGANIZATION INFORMATION EVENT ATTRACTIONS, FACILITIES AND SERVICES OF INTEREST *Mark all that apply EVENT PLANNING, SAFETY & MANAGEMENT Catered On-site / Off-site Barbeques / Grills Deep Fryers Ranges Woks Food Truck / Trailer YES NO YES NO YES NO YES NO YES NO On-Site Off-Site YES NO YES NO Lifeguard First Aid Booth Ambulance - BLS Ambulance - ALS Fire / Rescue YES NO YES NO YES NO Private Security - Unarmed Private Security - Armed Law Enforcement