FSEV2022-0007ADDITIONAL SITES
CHRONOLOGY
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT John Stojevich 2550 Ninth St., Suite
207 B
Berkeley CA 94710 (651)230-1708 john@planexperiential
.com
BILL TO Summit Series, We Work - Brent
Sutherland
901 Woodland st.Nashville TN 37206 (651)230-1708 brent@summit.co
OWNER HP LQ INVESTMENT LP 150 RADNOR CHESTER
RD STE A-270
RADNOR PA 19087 (651)230-1708
CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES
E-MAIL AARON HICKSON 11/1/2022 11/1/2022
Regarding the above submittal. Please upload any documents
for review. Usually a minimum of a site plan and description
of events is required.
CONDITIONS
Description: CONFERENCE, MEETING AND ENTERTAINMENT
Type: FIRE SPECIAL EVENT (WEB)Subtype: Status: FINALED Applied: 11/1/2022 EPRS
Parcel No: 658190011 Site Address: 49499 EISENHOWER DR LA QUINTA,CA 92253 Approved: 11/7/2022 KHET
Subdivision: TR 28545-3 Block: Lot: 30 Issued: ONLINE
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 11/11/2022 LIN
Valuation: $3,000,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details:
Printed: Wednesday, September 27, 2023 10:40:03 AM 1 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSEV2022-0007
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
FIRE FINAL**LIN 11/11/2022 11/11/2022 APPROVED
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE STATUS REMARKS NOTES
1ST PERMIT TECH (1
DAY)
AARON
HICKSON 11/1/2022 11/2/2022 11/1/2022 COMPLETE DELETED DUPLICATE FILES
1ST FIRE (2 WK)KOHL
HETRICK 11/1/2022 11/8/2022 11/7/2022 APPROVED COA IN
ATTACHMENTS
PARENT PROJECTS
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
FIRE SPECIAL EVENT
PERMIT 101-0000-42421 0 $263.00 $263.00 11/7/22 WEB13535 749560039 CREDIT John Stojevich EPRS
FIRE SPECIAL EVENT
PERMIT PC 101-0000-42420 0 $175.00 $175.00 11/7/22 WEB13535 749560039 CREDIT John Stojevich EPRS
Total Paid for FIRE FEES: $438.00 $438.00
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 11/7/22 WEB13535 749560039 CREDIT John Stojevich EPRS
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $8.00 $8.00 11/7/22 WEB13535 749560039 CREDIT John Stojevich EPRS
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $8.00 $8.00
TOTALS:$457.00 $457.00
Printed: Wednesday, September 27, 2023 10:40:03 AM 2 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSEV2022-0007
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 11/2/2022 Etrakit Public
Registration
1ST SUBMITTAL ART
INSTALLATION
ART INSTALL Adelita
Specs.pdf 1
DOC 11/2/2022 Etrakit Public
Registration
1ST SUBMITTAL
STATGES AND TENTS
ALL PLAN PSFD Summit
Palm Desert 2022 .pdf 1
DOC 11/2/2022 Etrakit Public
Registration
1ST SUBMITTAL
APPLICATION
APPLICATION Summit
Series LQ Special Event
Application.pdf
1
DOC 11/2/2022 Etrakit Public
Registration
1ST SUBMITTAL
STRUCTURAL
TENT SPEC 1 12 21 2022
LIB 2019 Quinoa 1st
Subm Calcs.pdf
1
DOC 11/2/2022 Etrakit Public
Registration Fire Watch Form FPS_x06-02_Fire_Watch
LQ.pdf 1
DOC 11/2/2022 Etrakit Public
Registration Fire Watch Schedule Summit FIre Watch 10-
31-22.xlsx.pdf 1
BOND INFORMATION
1ST BLDG NS (1
DAY)JAKE FUSON 11/2/2022 11/3/2022 11/2/2022 APPROVED-
CONDITIONS
-PROVIDE ELECTRICAL DESIGNS IF ON-SITE
GENERATORS ARE TO BE USED, INCLUDE SYSTEM
GROUNDING DESIGNS AND LOCATIONS OF
PANELBOARDS AND ELECTRICAL EQUIPMENT IF
UTILIZED.
NOTE: THIS REVIEW DOES NOT INCLUDE REVIEW
FOR DISABLED ACCESS, OWNER/OPERATORS TO
DETERMINE WHETHER STAGE AND OTHER SITE
FEATURES MUST BE ACCESSIBLE TO DISABLED
PERSONS AND MUST COMPLY WITH CBC &
FEDERAL ADA REQUIREMENTS AS APPLICABLE.
1ST PLANNING –
ETRAKIT (1 DAY)
CARLOS
FLORES 11/2/2022 11/3/2022 11/2/2022 APPROVED
Summit Series Event at LQ Resort - 11/9-11/13
MEETS ALLOWANCES WITHIN SPECIFIC PLAN, NO
SPECIAL EVENT PERMIT NEEDED
Printed: Wednesday, September 27, 2023 10:40:03 AM 3 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSEV2022-0007
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 11/2/2022 Etrakit Public
Registration
SUMMIT SERIES FPS x06
02 Fire Watch LQ.pdf 1
DOC 11/2/2022 Etrakit Public
Registration
Summit FIre
Watch_1.pdf 1
DOC 11/7/2022 KOHL HETRICK
PSFD_ Summit Palm
Desert _22 _ Fire
UPDATE_12032022.pdf
PSFD_ Summit Palm
Desert _22 _ Fire
UPDATE_12032022.pdf
1
DOC 11/7/2022 KOHL HETRICK
FSEV2022-0007 -
APPROVED
DOCUMENTS.pdf
FSEV2022-0007 -
APPROVED
DOCUMENTS.pdf
1
DOC 11/7/2022 KOHL HETRICK FSEV2022-0007 - COA
AND PERMIT CARD.pdf
FSEV2022-0007 - COA
AND PERMIT CARD.pdf 1
Printed: Wednesday, September 27, 2023 10:40:03 AM 4 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSEV2022-0007
La Quinta Office of the Fire Marshal
78-495 Calle Tampico
La Quinta, CA 92253
760-777-7000
Special Event Application
Event Name: Event Contact:
Event Address: Contact Phone:
City/Zip: Contact Email:
Event Date(s): Hours of Operation:
Daily Expected/Peak Attendance:
Description/Scope of Event:
Company Name: Applicant Name:
Address: Phone:
City/Zip: Email:
Food & Beverage:
Tents / Canopies:*Tents include any membrane structure with 1 or more sidewall / Canopy = No Sidewall
Tents >400 sq ft: Canopies >700 sq ft:
Copy of fire retardant certification provided:
Display / Vendor Booths:
Number of Booths: Cooking in any Booths:
Fuel Fire Generator Use:Quantity:
Temporary Special Event Structure (Stage, Platform, Rigging, Tower, etc):
Special Amusement / Ride Attractions:
Description:
Open Flame / Pyrotechnics Proposed:*Separate Pyro Permit may be
Description: required
Parking: Coordinated Parking Management:
Planned Emergency/Medical Service Provisions:
Level of Service:
Planned Traffic Routing Changes / Restrictions:
Event / Site Security Proposed:
Level of Service:
EVENT INFORMATION
APPLICANT/SPONSORING ORGANIZATION INFORMATION
EVENT ATTRACTIONS, FACILITIES AND SERVICES
OF INTEREST *Mark all that apply
EVENT PLANNING, SAFETY & MANAGEMENT
Catered On-site / Off-site Barbeques / Grills Deep Fryers Ranges Woks Food Truck / Trailer
YES NO
YES NO
YES NO
YES NO
YES NO
On-Site Off-Site YES NO
YES NO
Lifeguard First Aid Booth Ambulance - BLS Ambulance - ALS Fire / Rescue
YES NO
YES NO
YES NO
Private Security - Unarmed Private Security - Armed Law Enforcement
SUMMIT PALM DESERT
November 11-14, 2022
Stages or Tents
Over 400’sq
Flores Ballroom
main content space
Flores Ballroom
main content space
Fiesta Ballroom
Music space
Fiesta Ballroom
Music space
The Orchard Stage
Outdoor - Music on the Lawn
The Orchard Stage
Outdoor - Music on the Lawn
The Orchard Stage
Outdoor - Music on the Lawn
Haven
Outdoor - Tent at the Main
Pool Lawn
Haven
Outdoor - Tent at the Main
Pool Lawn
ALSO SUPPORTED BY (Quinoa)-1st Subm Calcs.pdf
(ATTACHED)
Haven
Outdoor - Tent at the Main
Pool Lawn
Stages, Tents, &
Art
Under 400’sq
The Studios
Late Night Music
Night Market and
Back Of House
UPDATED 11/3/2023
Night Market Zone
detail
UPDATED 11/3/2023
The Grove
Outdoor - Activation space
CHRIS CARNABUCCHI
ORCHARD - Adelita
CHRIS CARNABUCCHI
ORCHARD - Adelita
CHRIS CARNABUCCHI
ORCHARD - Adelita
1401 Dove Street, Suite 520 | Newport Beach, CA | 92660
949.503.5323 [Office]| www.morengineers.com
Date:
Project: Structural engineering for the Quinoa/Namaste Yoga structure in the
City of Bakersfield, CA.
Subject: Structural plans, details, and calculations.
Code: 2016 California Building Code/Title 24
Engineer of: Kyle Morris
Record
Notice: The content of these documents is understood to be an
expression of professional opinion. It is based on our best
knowledge, information and belief. No guarantee or
warranty is expressed or implied.
(Lightning In A Bottle
CA.
2017)
Dec. 21, 2018
THIS STRUCTURE HAS PREVIOUSLY BEEN PLAN CHECKED
FOR LIGHTNING IN A BOTTLE 2018 FESTIVAL. THESE
CALCULATIONS HAVE BEEN UPDATED FOR CODE. THERE
ARE NO CHANGES TO THE DESIGN OR INSTALLATION.
Structural Criteria
The following calculations and details are for temporary structures for the Lightning In A Bottle
Festival in the city of Bakersfield, CA. The structures will be constructed from May 22 through May 27
2019. The structures are meant to be placed in direct contact with the soil with no special foundation
required.
Structures Notes (2019)
1. Structures/plans have been designed and shall comply with the 2016 California Building Code.
2. Structures have been designed for material weight and wind loading (wind loading governing
over seismic loading). Structures designed for 60 MPH.
3. Structures have not been designed for occupant loads (No people allowed on structure).
Evacuation Program (2019)
If wind speeds/gusts exceeding 45 MPH, do the following immediately:
1. For structures with sails, sails shall be cut away from the structure. Structures with solid
surfaces, provide tie downs with tent stakes.
2. People should be evacuated a minimum of 100 feet away from the structure in all
directions.
3. As a condition of approval, either Kyle Morris of Mor Engineers Inc, or one of his engineers, will
monitor the wind and structures and provide direction for evacuation and the cutting of
sails/providing tie downs for the duration of the event. Wind speed is monitored on via online
weather report and wind monitors provided onsite. If wind speeds are predicted/reported to be 45
mph gusts or more, Kyle Morris will contact the artist and on-site security to monitor the structures
or remove fabric/areas that catch the wind. Cables are to remain in place.
4. People may return when weather reports document wind speeds will remain below 45 mph and also
given the release from Mor Engineers Inc.
Contact Info
Kyle Morris
Mor Engineers Inc.
kyle@morengineers.com
Office 949-502-5323
Mobile 714-943-2384
Cable/Wire Rope 6x19
Steel Plate A36
W‐Shaped Steel Beams A36 (Min)
2x/4x Lumber Douglas‐Fir Larch #1
Plywood ASX Ext. 1
Pipes ASTM A53 Grade‐B (Schedule 40)
Welds E70XX
Poles Southern Pine ASTM D25
Steel Bolts A307 Grade 5
Nylon Tether See attached certificate
All general materials noted. Not all may apply to this particular structure.
Material Specifications
SIMILAR BUILD TYPE FOR NAMASTE YOGA STRUCTURE
SIMILAR BUILD TYPE FOR NAMASTE YOGA STRUCTURE
SIMILAR BUILD TYPE FOR NAMASTE YOGA STRUCTURE
Pictures for Detail A
Picture for Detail B
Kz 0.9 T 27.3‐1
Kzt 1 26.8‐1
Kd 0.85 T 26.6‐1
V 100 Fig. 26.5‐1A
V' 75 ASCE 37‐02 6.2.1
q 11.016 27.3‐1
G 0.85 26.9.1
CN 1.1 Fig. 27.4‐5
p 10.29996 psf 27.4‐3
0.6*p (ASD) 6.179976 psf
Penetrators
A (ft^2)3150 ft^2
F 19466.92 lbs
Number of Bases 14
F per penetrator 1390.495 lbs
Number of Stakes Per 2
F per Stake 695.2473 lbs Tent Stake Capacity: 800 lbs
Tension Cables
F per cable (2) 695.2473 lbs <= 2740 lb (Factor of Safety of 2) for 1/4" Cable
Columns
6x6 slenderness ratio 43.63636
4x4 slenderness ratio 44.57143
Wind Calc per ASCE 7‐10 Section 27.4.3
OFFICE OF THE FIRE MARSHAL – LA QUINTA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
November 7, 2022
Plan Experiential
2550 Ninth Street, Suite 207 B
Berkeley, CA 94710
Re: Special Event / Exhibits & Trade Shows / Tent / Canopy – Construction and Operational Fire
Plan Review – SUMMIT SERIES @ LQ RESORT
FSEV2022-0007 / 49499 EISENHOWER DRIVE, LA QUINTA, CA 92253
11/11/2022 TO 11/13/2022
The plans you submitted for the above referenced project have been reviewed by Riverside County Fire
Department - Office of the Fire Marshal personnel and are approved with the following conditions.
FIRE LANES/ACCESS [CFC 503]
No designated fire lanes, fire hydrants or any other Fire Department appliances shall be blocked or
obstructed. Fire lanes shall be clearly identified in an approved manner throughout the event grounds by
posting “NO PARKING FIRE LANE” or other approved means. All motor vehicles shall be parked in
designated parking areas.
GENERATORS AND INTERNAL COMBUSTION POWER SOURCES
Generators (and/or internal combustion power sources) shall be separated from temporary membrane
structures, tents, canopies by a minimum of 20 feet and be isolated from contact with the public [CFC
3107.16]. Additional fuel containers will not be allowed to be stored with the generator. Each generator will
need to have a 10BC fire extinguisher, with a current service tag (within one year). Combustible material
(including trash) shall be kept clear of the generators.
EXTENSION CORDS
Extension cords shall be over-current protected and/or ground-fault interrupter protected. No additional taps
are to be in any device. All extension cords shall be of 12/3 gauge wire or greater with approved connectors.
HEATING AND COOKING EQUIPMENT [CFC 3107.12]
At least one 2A10BC fire extinguisher, with a current service tag (within one year), shall be provided at all
vendor booths that are cooking. One Class K type fire extinguisher, with a current service tag (within one
year), shall be provided for each vendor booth with a deep fat fryer. Deep fat fryers shall be located outside
tents and protected from the public, unless otherwise directed or approved by The Department of
Environmental Health and the Fire Department.
All L.P.G. tanks (empty or full) shall be secured with a chain or other approved device to prevent tipping
over/unintentional movement and kept a safe distance from open flame. The pressure relief vent should be
pointed away from any open flame.
COMBUSTIBLE MATERIAL [CFC 3107.19]
Accumulation of combustible material (including trash) will be prohibited near any ignition sources within
30-feet of the perimeter of tents and membrane structures. Such waste shall be stored in approved containers
and removed from the premises not less than once a day.
TENTS AND CANOPY(S) [CFC Chapter 31]
Tents over 400 square feet and canopies over 700 square feet shall comply with the following conditions:
[1] Extinguishers- At least one 2A10BC fire extinguisher, with a current service tag (within one year),
shall be provided within every 75 feet of travel distance. [CFC 3107.9]
[2] Exit Signs and Egress Lighting- Tents with side walls shall have illuminated exit signs and means of
egress lighting pursuant to CFC Chapter 31 when the tent has an occupant load of 50 or more. [CFC
3103.12.6 & .7]
[3] Seating Configuration- Seating configuration needs to comply with CFC Chapter 10 and California
Code of Regulations (CCR) Title 19.
[4] No Smoking- Smoking shall not be permitted in any tent or canopy or in any adjacent area where
hay, sawdust or any other combustible materials are stored. NO SMOKING signs shall be
conspicuously posted in all tents and canopies open to the public. [CFC 3107.3]
[5] Alternative Anchorage – The alternative concrete weight ballasting is approved with the conditional
requirement that each of the tent or canopy legs to be affixed or secured to the weight ballast. The
leg shall be secured within 12-inches of the ground.
[6] Obstructing exits- Furnishings, decorations or other objects shall not be placed so as to obstruct
exits, access thereto, egress therefrom, or visibility thereof. Hangings and draperies shall not be
placed over exit doors or otherwise be located to conceal or obstruct an exit. [CFC 3107.20]
[7] Decorative Materials- Curtains, draperies, hangings and other decorative materials suspended from
walls or ceilings shall meet the flame propagation performance criteria of CCR Title 19 in
accordance with section 807.2 or be non-combustible, when the tent has an occupant load of 50 or
more. [Ref CFC 807.1]
[8] High-Wind Evacuation Plan – The tent supplier and event coordinator shall understand that the use
of the tent or canopy in winds at 40 mph or greater is not permitted. Event coordinator is
responsible to take necessary actions to stop occupancy and use of the tent or canopy when winds of
40 mph or greater are observed or expected.
FOOD TRUCKS
All food truck apparatus shall be of the motorized type to provide easy relocating and evacuation in the
event of an emergency or where otherwise required. All food trucks shall have their own compliment of a
minimum 2A10BC (5lb) fire extinguisher under current service tag. All food trucks that have fuel-fire
equipment shall be provided with adequate ventilation and a commercial kitchen hood extinguishing system.
The hood, plenum and duct shall be maintained in a clean and safe operation. The hood suppression system
shall be operational and provided with current service tag
TEMPORARY AMUSEMENT RIDES
None Proposed
DESIGNATED SMOKING AREAS [CFC 3106.4.5]
Smoking shall be permitted only in designated areas. Other areas shall have approved “No Smoking” signs
conspicuously posted and maintained.
FIREWORKS/PYRO/FIRE PERFORMERS
Fireworks, pyrotechnics or fire performers shall require an additional permit and approval.
CROWD MANAGERS [CFC 3106.4.3]
A minimum of 1 trained crowd manager for every 250 persons in attendance is required to be functioning
during the hours of the event. The Crowd Manager's duties shall follow the requirements of CFC 403.12.3.3.
PUBLIC SAFETY COORDINATION/CONTACT INFORMATION
At the time of the fire inspection, provide the onsite contact information for all public safety points of
contact (ex. Sheriff, contracted medical staff, private security, parking supervisor, life guard etc.). Provide
any information for any pre-event safety meetings.
ASSEMBLY AND MAXIMUM OCCUPANT LOADS
Assembly functions and gatherings of more than 50 persons shall be provided with adequate means of
egress access in compliance with the expected occupant loads. Identified maximum occupant loads for
rooms or spaces shall not be exceeded and shall be controlled.
MAINTENANCE OF AISLES
Minimum clear width of aisles and pathways to means of egress shall be in compliance with applicable
sections of CFC Chapter 10.
PLANNED BLOCKING OF EXITS AND EXIT ACCESSES
For indoor assembly rooms, banquet halls and conference centers with many points of Exit Access, plans for
blocking and screening Exit doorways and Exit Access points shall be approved. Where Exit elements are
approved to be blocked and screened, illuminated Exit signs shall be covered.
INTERIOR FINISH AND DECORATIVE MATERIALS
Interior finish, interior trim, furniture, furnishings and decorative materials, including decorative vegetation,
used in exhibition areas shall comply with the CFC Chapter 8 for fire resistance rating. The materials used
for interior wall and ceiling finish of exhibit booths and displays in exhibition areas shall comply with one
of the following:
o Non-sprinklered – Class A finish in accordance with CFC 803
o Sprinklered – Class B finish in accordance with CFC 803
FIRE ALARM NOTIFICATION MAINTENANCE
Building and Occupancy Fire Alarm Systems with Notification appliances shall be maintained in an
operational state. A proposal for disconnecting sensing and notification circuits was provided and is
approved with the specific requirement of a Fire Watch during the periods that the Fire Alarm system is
altered.
ONSITE FIRE WATCH
This Special Event requires an onsite Fire Watch by trained personnel. Documentation and reporting of the
Fire Watch shall be maintained on the RVC Fire Prevention Standard 06-02 log sheet and provided to the
Office of the Fire Marshal within 24-hours of activation.
FIRE INSPECTION
Prior to this Special Event, you must be cleared by the Fire Department by way of a Pre-Event Fire Safety
Inspection.
STRUCTURAL BUILDING INSPECTION
Prior to this Special Event, you must be cleared by the La Quinta Building Department by way of a facility
and temporary event structure inspection. Call (760)777-7153 or (760)777-7125 to schedule the inspection
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
RIVERSIDE COUNTY FIRE PROTECTION PLANNING
RECORD OF INSPECTIONS / PERMIT CARD
THIS CARD IS TO REMAIN ON SITE AT ALL TIMES.
INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE.
JOB
ADDRESS: PERMIT#: DATE
ISSUED:
DESCRIPTION: CONTRACTOR:
HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS
Thrust block pre-pour Door fan test
UG rough piping Abort test
UG hydro Mechanical shutdown
Flush Detector test
Final E F Deluge/pre-action
SPRINKLER U.G. Final E F
Thrust block pre-pour UST/AST TANK
UG rough piping Installation
UG hydro Removal
Flush Emergency shut off
Final E F Primary piping
FIRE SPRINKLER Secondary piping
Weld inspection Dispensers & shear valves
Overhead rough piping Final E F
Overhead hydro MISC. INSPECTIONS
UG flush / OK to connect Spray booths
Main drain/inspectors’ test Hood/duct extinguishing
High pile storage High pile rack storage
In-rack sprinklers H.P. vents/access/corridors
Hose racks Tract access/hydrant verification
Final E F Access & Address verification
HOOD EXTINGUISHING OTHER CONST. PERMIT
Detection system
Function test
Gas/electrical shut-off
Nozzle model/placement
Fire alarm connection
Final E F
SPRAY BOOTHS FIRE CODE PERMIT(S)
Installation OUTDOOR PUBLIC EVENT
Air flow test SPEC. AMUSEMENT STRUCTURE
Mechanical interlock TENT/CANOPY
Extinguishing system
Fire alarm connection
Final E F
FIRE ALARM KNOX SYSTEM
Rough-wire inspection Building Knox box
Function test Gate access Knox box/padlock
Duct detectors/velocity BUILDING INSPECTIONS
24 hr. battery test T/I final
Sprinkler monitoring Shell final
Final E F Final for occupancy
FINAL INSPECTION DATE: INSPECTORS SIGNATURE:
**WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE**
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
INSPECTION NOTES
1. Sway bracing and hangers will be inspected at the time of rough piping inspection.
2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler
Systems)
3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be requi red.
4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test.
5. Contractor shall supply all testing equipment, access and operating instructions at time of test.
6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the
affected system to be covered or hidden.
POLICIES ON FIELD INSPECTIONS
A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when
scheduling inspections. For City of La Quinta inspections call: (760) 777-7131.
B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence
without approved plans.
C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required
to schedule the necessary inspections and be present on site for inspections.
D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not
on site or where previously noted corrections have not been completed.
E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into
the structure until clearance has been granted by the Fire Dept and Building Official.
F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance
has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official.
INSPECTION NOTES:
THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE
AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS.
THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180
DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE.
THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE
REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.