Loading...
FSEV2023-0004ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT TOWN AND COUNTRY EVENT RENTALS 7725 AIRPORT BUSINESS PARK WAY VAN NUYS CA 91406 (818)489-1295 laurent@tacer.biz BILL TO TOWN AND COUNTRY EVENT RENTALS 7725 AIRPORT BUSINESS PARK WAY VAN NUYS CA 91406 (818)489-1295 info@tacer.biz CONTRACTOR TOWN AND COUNTRY EVENT RENTALS 7725 AIRPORT BUSINESS PARK WAY VAN NUYS CA 91406 (818)489-1295 lminniti@tacer.biz OWNER TOWN AND COUNTRY EVENT RENTALS 7725 AIRPORT BUSINESS PARK WAY VAN NUYS CA 91406 (818)489-1295 info@tacer.biz CONDITIONS Description: MADISON CLUB - SPRING EVENTS TENT Type: FIRE SPECIAL EVENT (WEB)Subtype: Status: FINALED Applied: 2/27/2023 ECON Parcel No: 767871006 Site Address: 53035 MERIWETHER WY LA QUINTA,CA 92253 Approved: 3/16/2023 KHET Subdivision: TR 34969 Block: Lot: 1 Issued: 3/21/2023 ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/21/2023 LRO Valuation: $30,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Wednesday, September 27, 2023 12:02:48 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSEV2023-0004 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FIRE INSPECTOR LRO 3/18/2023 3/18/2023 APPROVED TENT CONSTRUCTION INSP FIRE FINAL**LRO 3/21/2023 3/21/2023 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 2/27/2023 2/28/2023 2/28/2023 COMPLETE PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL FIELD INSPECTIONS (EXCESSIVE) EACH 101-0000-42421 0 $175.00 $175.00 3/21/23 WEB14692 836770519 CREDIT AEC913 ECON FIRE SPECIAL EVENT PERMIT 101-0000-42421 0 $263.00 $263.00 3/21/23 WEB14692 836770519 CREDIT AEC913 ECON FIRE SPECIAL EVENT PERMIT PC 101-0000-42420 0 $175.00 $175.00 3/21/23 WEB14692 836770519 CREDIT AEC913 ECON Total Paid for FIRE FEES: $613.00 $613.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 3/21/23 WEB14692 836770519 CREDIT AEC913 ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $8.00 $8.00 3/21/23 WEB14692 836770519 CREDIT AEC913 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $8.00 $8.00 TOTALS:$632.00 $632.00 Printed: Wednesday, September 27, 2023 12:02:48 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSEV2023-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 2/27/2023 Etrakit Contractor 1ST SUBMITTAL TENT STRUCTURE 18m x 50m - 59_x164_ Structure 13_ Legs.pdf 1 DOC 2/27/2023 Etrakit Contractor 1ST SUBMITTAL Event Diagram Madison Club Lot 3 v4.pdf 1 DOC 3/14/2023 Etrakit Contractor Engineering Stamp UT-7449-23 The Madision Club 18Mx50M Tent_Signed.pdf 1 DOC 3/16/2023 KOHL HETRICK Losberger Liri 18m Roof Cover Flame Certificate.pdf Losberger Liri 18m Roof Cover Flame Certificate.pdf 1 DOC 3/16/2023 KOHL HETRICK LQ Special Event Application 031623.pdf LQ Special Event Application 031623.pdf 1 DOC 3/16/2023 KOHL HETRICK Madison Club Lot 3 Final 1-16.pdf Madison Club Lot 3 Final 1-16.pdf 1 DOC 3/16/2023 KOHL HETRICK Tent 20xExpandable White Flame Certificate.pdf Tent 20xExpandable White Flame Certificate.pdf 1 BOND INFORMATION 1ST FIRE (2 WK)KOHL HETRICK 2/27/2023 3/13/2023 3/16/2023 APPROVED SEE ATTACHMENTS Emailed applicant as the submittal is incomplete and requires the LQ Fire Special Event Permit Application and additional floorplan and decoration details of the tent. All required details provided. Approved. Will require 2 inspections. 1st inspection is of the tent construction completion. 2nd is of the tent decorations, furnishings and uses completed and ready for use. Printed: Wednesday, September 27, 2023 12:02:48 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSEV2023-0004 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/16/2023 KOHL HETRICK UT-7449-23 The Madision Club 18Mx50M Tent_Signed.pdf UT-7449-23 The Madision Club 18Mx50M Tent_Signed_1.pdf 1 DOC 3/16/2023 KOHL HETRICK Voile White Flame Resistance Certificate v1.pdf Voile White Flame Resistance Certificate v1.pdf 1 DOC 3/16/2023 KOHL HETRICK Man Cave 2023 Lighting.pdf Man Cave 2023 Lighting.pdf 1 DOC 3/16/2023 KOHL HETRICK Tent Kitchen Details.pdf Tent Kitchen Details.pdf 1 DOC 3/16/2023 KOHL HETRICK FSEV2023-0004 - COA AND JOB CARD.pdf FSEV2023-0004 - COA AND JOB CARD.pdf 1 DOC 3/16/2023 KOHL HETRICK FSEV2023-0004 - APPROVED PLANS AND DOCUMENTS.pdf FSEV2023-0004 - APPROVED PLANS AND DOCUMENTS.pdf 1 Printed: Wednesday, September 27, 2023 12:02:48 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSEV2023-0004 APPROVED By: FIRE SAFETY SPECIALIST 03/16/2023 2:01:05 PM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. PERMIT # -FSEV2023-0004 64'-0"Structure 60'x164' Frame Tent 20'x60' Subfloor 64'x168' Plywood/Kitchen 20'x64' Fire Lane Fire Lane Fire Lane Fire Lane Fire Lane N 81610 Shackleton WayAccess Access ADA - Access Ramp TBD during Site visit 20'-0" 8'x20' Fire Exit 60' Open Top TentGlass Windows (3) 4'x12' 8'x20'8'x20'8'x28'8'x28'8'x32'8'x32'20'x40' X-Braces X-Braces H/VACH/VAC H/VAC X-Braces X-Braces H/VAC X-Braces H/VAC X-Braces 8' EXIT DOOR8' STAFFEntrance DoorH/VAC EXITEXIT168'-0" 20'x60' Kitchen Frame Tent Double Door Double Door Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Plywood Floor Plywood Floor0 10 20 30 40 50 FT Town & Country 7725 Airport Business Park Way (818) 908-4211 TACER.BIZ Van Nuys, CA 91406 The Madison Club Lot 3 53035 Merriwether Way Consultant: Designer: Drawn By: Scale: Install Date: Event Date: Strike Date: Guest Count:Page Size: 3/15/23 4/8/23 4/11/23 TBD Laurent Minniti N/A Laurent Minniti 1/32" = 1'11"x17" EVENT ID#: R2: R3: R4: R5: R6: R7: R8: R9: R10: R11: R12: R13: R14: 2/22/23 La Quinta, CA 92253 Copyright C Town & Country Event Rentals, All Rights Reserved. No part of this publication may be reproduced, or transmitted in any form by any means - electronic, photocopying, or otherwise - without the express written consent of Town & Country Event Rentals. R15: Date: Feb 22, 2023 Time: 10:46:41 AM File name: Madison Club Lot 3 v3.vwx K K EXIT Cordoban Brown Subfloor 64'x168' = 10,496 sqft Cordoban Brown Terraces = 1,328 sqft Plywood for Prep Tent 22'x64' = 1,408 sqft Plywood Ramp TBD = 128 sqft Fire Lane Fire Lane Structure 60'x164' - Frame Tent 20'x60' 8'x16'8'x24'8'x24'8'x16'4'x12' Plexiglas Railing 16'x40'BBQC/OC/O8'FRY 8'griddle8'8'8'x8' Plywood Ramp Cordoban Brown Plywood + Astro Turf K 8'8'TCTCTCTC RcFzDD REF.DD REF.4'6'4'4'4'8'8'8'SINK8'8' EXIT DOOR w/ glass 8'8'stainless tablesTerraces/Stairs Cordoban Brown H/VACPlywood RampTBDsame level as main floor Glass Windows Glass Windows X-Braces X-Braces H/VACH/VAC H/VAC X-Braces X-Braces H/VAC X-Braces H/VAC H/VAC EXITEXITGlass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass WindowsGlass WindowsGlass Windows168'-0" 640 384 256486" step6" step6" step6" step6" step6" step22'-0"15'-0" 8' EXIT DOOR w/ glass white wall X-Braces white wall white wall white wall white wall white wall white wallwhite wallwhite wall w/Doorswhite wall w/DoorsTown & Country 7725 Airport Business Park Way (818) 908-4211 TACER.BIZ Van Nuys, CA 91406 The Madison Club Lot 3 81610 address 53035 Merriwether Way Consultant: Designer: Drawn By: Scale: Install Date: Event Date: Strike Date: Guest Count:Page Size: 3/15/23 4/8/23 4/11/23 TBD Laurent Minniti N/A Laurent Minniti 1/16" = 1'11"x17" EVENT ID#: R2: R3: R4: R5: R6: R7: R8: R9: R10: R11: R12: R13: R14: 2/22/23 3/13 - Final 3/11/23La Quinta, CA 92253 Copyright C Town & Country Event Rentals, All Rights Reserved. No part of this publication may be reproduced, or transmitted in any form by any means - electronic, photocopying, or otherwise - without the express written consent of Town & Country Event Rentals. R15: E033786 Plywood starts 15' away from grass ABC F/E ABC F/E ABC F/E ABC F/E ABC F/E ABC F/E ABC F/E ABC F/EABC F/EABC F/E ABC F/E Type K F/E 13'-0"9'-7 3/4"16'-4 7/8"13'-3"22'-7 3/4"242 594 242 242 242242 16'-4 7/8"13'-3"164'-0 1/2"59'-0 5/8"16'-4 7/8"16'-4 7/8"Town & Country 7725 Airport Business Park Way (818) 988-4211 TACER.BIZ Van Nuys, CA 91406 18m x 50m / 59' x 164' Uniflex - 13' Legs Copyright C Town & Country Event Rentals, All Rights Reserved. No part of this publication may be reproduced, or transmitted in any form by any means - electronic, photocopying, or otherwise - without the express written consent of Town & Country Event Rentals. MAXIMUM WEIGHT LOADS IF WEIGHT IS SPREAD OUT OVER THE WIDTH OF THE ENTIRE ARCH. MAXIMUM WEIGHT LOAD PER ARCH FROM PEAK ONLY. (NOTHING ELSE MAY BE HUNG FROM THE SAME ARCH!) WEIGHT LOADS RIDGED "X" BRACES EVERY 4 - 5 BAYS & ALL BAY ENDS 1,750 LB CONCRETE BLOCK: USING "A" OR "B" BALLAST CRADLE ONE BLOCK PER LEG. TWO BLOCKS ON LEGS THAT SUPPORT CROSS BRACES. USE MEDEIUM SIZE BEAM CLAMPS. STAKES: DEPENDING ON WEATHER CONDITIONS EXITH/VAC 8' STAFFEntrance8'x20' Fire Exit H/VAC 8' EXIT DOORH/VAC Tuesday: Dessert Wed - Sat: Breakfast Wagon Carts/Tiered display Split between fruit/pastry / salsa topping bar Vermont Island & Carving board 8’ ice Con & 3 Chafers 4 Transit Cabinets FreezerDouble Door Fridge2 Stainless Steel Tables8’8’8’4’Hand WashDouble Door FridgeOpen/uncovered area for any propane/cooking equipment 8’6’4’ 8’8’8’Trash Trash Trash Trash Trash Storage & Scullery Only 4’Liquid Dirty Dishes Dirty GlassDrop tableSort table8’Clean GlassLinen/ Roll Up Station Clean DishScrape/Sort Linen 40’GeneratorRamp8’8’Convectrion Ovens (2)SUBFLOOR Grass/Dirt Lot 8’GriddleDeep Fryer4’20’Smoker8’Trash Trash Trash Enclosed Tent w/ AC - Direct entry to Structure SchakeltonDirt DrivewayGrill Charcoal8’Generator to be at least 20-feet from side of tent structure and screened from access. Shall be grounded. Cordoban Brown Subfloor 64'x168' = 10,496 sqft Cordoban Brown Terraces = 1,328 sqft Plywood for Prep Tent 22'x64' = 1,408 sqft Plywood Ramp TBD = 128 sqft Fire Lane Fire Lane Fire Lane 81610 Shackleton WayDrive RangeNStructure 60'x164' - Frame Tent 20'x60' 8'x16'8'x24'8'x24'8'x16'4'x12' Plexiglas Railing 16'x48'BBQC/OC/OFRY griddle8'8'x8' Plywood Ramp X-Braces Cordoban Brown Plywood + Astro K 8'8'TCTCTCTC RcFzDD REF.DD REF.4'6'4'4'4'8'8'SINK8'8' EXIT DOOR 8'8'stainless tablesMulch berm Mulch berm Terraces/Stairs Cordoban Brown H/VACPlywood RampTBDsame level as main floor Glass Windows Glass Windows X-Braces H/VAC H/VAC H/VAC H/VAC H/VAC EXITEXITGlass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass Windows Glass WindowsGlass WindowsGlass Windows8' EXIT DOOR 168'-0"64'-0"640 384 256486" step6" step6" step6" step6" step6" step22'-0" 15'-0" 0 10 20 30 40 50 FT Town & Country 7725 Airport Business Park Way (818) 908-4211 TACER.BIZ Van Nuys, CA 91406 The Madison Club Lot 3 81610 address 53035 Merriwether Way Consultant: Designer: Drawn By: Scale: Install Date: Event Date: Strike Date: Guest Count:Page Size: 3/15/23 4/8/23 4/11/23 TBD Laurent Minniti N/A Laurent Minniti 1/32" = 1'11"x17" EVENT ID#: R2: R3: R4: R5: R6: R7: R8: R9: R10: R11: R12: R13: R14: 2/22/23 La Quinta, CA 92253 Copyright C Town & Country Event Rentals, All Rights Reserved. No part of this publication may be reproduced, or transmitted in any form by any means - electronic, photocopying, or otherwise - without the express written consent of Town & Country Event Rentals. R15: Date: Feb 22, 2023 Time: 10:46:41 AM File name: Madison Club Lot 3 v3.vwx Wht WallWht WallSmoker8'Generator Generator for HVAC ONLY Lighting/ Kitchen GeneratorLighting/ Kitchen Ramp RampGlass WindowsGlass Windows Vinyl Wall for ACVinyl Wall for AC Vinyl Wall for AC Vinyl Wall for ACVinyl Wall for ACGlass door w/ clear vinyl surroundGlass door w/ clear vinyl surroundGlass door w/ clear vinyl surround Glass door w/ clear vinyl surround Glass door w/ clear vinyl surroundGlass door w/ clear vinyl surroundGeneratorLighting/ KitchenPool TableFooseball 12 player Air HockeyShueboard Beer Pong Beer Pong Ping PongBAR DJ IV Station Beer Pong Beer Pong 8’ L 3’ W Generator to be at least 20-feet from side of tent structure and screened from access. Shall be grounded. 64'-0"X-Braces EXITEXITH/VACH/VAC H/VAC X-Braces X-Braces H/VAC X-Braces H/VAC X-Braces 8' STAFFEntrance22'-0" 8'x20' Fire Exit H/VAC 60'X-Braces 8' EXIT DOORH/VAC 24’ stage, 10 Esp Wall, 6’ blk bar for Scoring EXITarcade gamesPool TablePool TableFooseball 12 player Air HockeyShueboard Beer Pong Beer Pong Ping PongBAR This to certify that the material describe has been tested according to National Fire Protection Association Standard Methods of Fire Test for Flame-Resistant Textiles and Film (2004 Edition), and meets the requrements stated therein for fabric or other materials used in curtains, draperies, or other window treatments. The terms curtains, draperies, or other window treatments, include, but are not limited to: window curtains, stage or theatre curtains, vertical folding shades, roll-type window shades, hospital privacy curtains, window draperies, fabric vertical shades or blinds, horizontal folding shades, fabric horizontal shades or blinds, table skirts, table linens, disply booth separators, and textile wall hangings.shades or blinds, table skirts, table linens, disply booth separators, and textile wall hangings. The flame resistant is durable to washing. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org March 16, 2023 Town & Country Event Rentals 7725 Airport Business Park Way Van Nuys, CA 91406 Re: Special Event / Tent / Canopy – Construction and Operational Fire Plan Review – MADISON CLUB – SPRING EVENTS TENT FSEV2023-0004 / 53035 MERIWETHER WAY, LA QUINTA, CA 92253 The plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. FIRE LANES/ACCESS [CFC 503] No designated fire lanes, fire hydrants or any other Fire Department appliances shall be blocked or obstructed. Fire lanes shall be clearly identified in an approved manner throughout the event grounds by posting “NO PARKING FIRE LANE” or other approved means. All motor vehicles shall be parked in designated parking areas. GENERATORS AND INTERNAL COMBUSTION POWER SOURCES Generators (and/or internal combustion power sources) shall be separated from temporary membrane structures, tents, canopies by a minimum of 20 feet and be isolated from contact with the public [CFC 3107.16]. Additional fuel containers will not be allowed to be stored with the generator. Each generator will need to have a 10BC fire extinguisher, with a current service tag (within one year). Combustible material (including trash) shall be kept clear of the generators. EXTENSION CORDS Extension cords shall be over-current protected and/or ground-fault interrupter protected. No additional taps are to be in any device. All extension cords shall be of 12/3 gauge wire or greater with approved connectors. HEATING AND COOKING EQUIPMENT [CFC 3107.12] At least one 2A10BC fire extinguisher, with a current service tag (within one year), shall be provided at all vendor booths that are cooking. One Class K type fire extinguisher, with a current service tag (within one year), shall be provided for each vendor booth with a deep fat fryer. Deep fat fryers shall be located outside tents and protected from the public, unless otherwise directed or approved by The Department of Environmental Health and the Fire Department. All L.P.G. tanks (empty or full) shall be secured with a chain or other approved device to prevent tipping over/unintentional movement and kept a safe distance from open flame. The pressure relief vent should be pointed away from any open flame. COMBUSTIBLE MATERIAL [CFC 3107.19] Accumulation of combustible material (including trash) will be prohibited near any ignition sources within 30-feet of the perimeter of tents and membrane structures. Such waste shall be stored in approved containers and removed from the premises not less than once a day. TENTS AND CANOPY(S) [CFC Chapter 31] Tents over 400 square feet and canopies over 700 square feet shall comply with the following conditions: [1] Extinguishers- At least one 2A10BC fire extinguisher, with a current service tag (within one year), shall be provided within every 75 feet of travel distance. [CFC 3107.9] [2] Exit Signs and Egress Lighting- Tents with side walls shall have illuminated exit signs and means of egress lighting pursuant to CFC Chapter 31 when the tent has an occupant load of 50 or more. [CFC 3103.12.6 & .7] [3] Seating Configuration- Seating configuration needs to comply with CFC Chapter 10 and California Code of Regulations (CCR) Title 19. [4] No Smoking- Smoking shall not be permitted in any tent or canopy or in any adjacent area where hay, sawdust or any other combustible materials are stored. NO SMOKING signs shall be conspicuously posted in all tents and canopies open to the public. [CFC 3107.3] [5] Alternative Anchorage – The alternative concrete weight ballasting is approved with the conditional requirement that each of the tent or canopy legs to be affixed or secured to the weight ballast. The leg shall be secured within 12-inches of the ground. [6] Obstructing exits- Furnishings, decorations or other objects shall not be placed so as to obstruct exits, access thereto, egress therefrom, or visibility thereof. Hangings and draperies shall not be placed over exit doors or otherwise be located to conceal or obstruct an exit. [CFC 3107.20] [7] Decorative Materials- Curtains, draperies, hangings and other decorative materials suspended from walls or ceilings shall meet the flame propagation performance criteria of CCR Title 19 in accordance with section 807.2 or be non-combustible, when the tent has an occupant load of 50 or more. [Ref CFC 807.1] [8] High-Wind Evacuation Plan – The tent supplier and event coordinator shall understand that the use of the tent or canopy in winds at 40 mph or greater is not permitted. Event coordinator is responsible to take necessary actions to stop occupancy and use of the tent or canopy when winds of 40 mph or greater are observed or expected. ASSEMBLY AND MAXIMUM OCCUPANT LOADS Assembly functions and gatherings of more than 50 persons shall be provided with adequate means of egress access in compliance with the expected occupant loads. Identified maximum occupant loads for rooms or spaces shall not be exceeded and shall be controlled. OPEN FLAMES & CANDLES Candles, torches or similar that produce an open flame effect shall be approved prior to use in assembly areas, dining areas of restaurants and drinking establishments. Candle devices shall be located within stable candle holders the are resistant to tipping over. In the event of tipping over the candle wick and flaming element shall not extend beyond the opening of the candle holder. All combustible decorations, including floral arrangements, shall not be located near or above the placement of the open flame device(s). FOOD TRUCKS All food truck apparatus shall be of the motorized type to provide easy relocating and evacuation in the event of an emergency or where otherwise required. All food trucks shall have their own compliment of a minimum 2A10BC (5lb) fire extinguisher under current service tag. All food trucks that have fuel-fire equipment shall be provided with adequate ventilation and a commercial kitchen hood extinguishing system. The hood, plenum and duct shall be maintained in a clean and safe operation. The hood suppression system shall be operational and provided with current service tag TEMPORARY AMUSEMENT RIDES Amusement and Carnival rides shall have current Cal/OSHA certification tag, portable fire extinguisher with current annual service tag and be installed/constructed on stable ground or foundation. All rides shall have a stopping device within reach of the operator for use in case of an emergency. Equipment Operators shall be trained in the specific operation of the particular ride. The operator shall be in good health and of sound mind. PORTABLE OUTDOOR GAS-FIRED HEATERS The storage or use of portable outdoor gas-fired heating appliances is prohibited inside tents, canopies and membrane structures. The heating appliance shall be located not less than 5-feet from buildings, exits and exit discharges. The heating appliance shall not be located beneath or closer than 5-feet to combustible decorations and combustible overhangs, awnings, sunshades or similar combustible attachments to buildings. Heating appliances shall be listed and labeled in accordance with ANSI Z83.26/CSA2.37 and provided with a tip-over switch that automatically shuts off the flow of gas if the appliance is tilted more than 15 degrees from vertical. PORTABLE OUTDOOR FIREPLACES Portable outdoor fireplaces shall be used in accordance with the manufacturer’s instructions and shall not be operated within 15 feet (3048 mm) of a structure or combustible material. DESIGNATED SMOKING AREAS [CFC 3106.4.5] Smoking shall be permitted only in designated areas. Other areas shall have approved “No Smoking” signs conspicuously posted and maintained. FIREWORKS/PYRO/FIRE PERFORMERS Fireworks, pyrotechnics or fire performers shall require an additional permit and approval. FIRE INSPECTION Prior to this Special Event, you must be cleared by the Fire Department by way of a Pre-Event Fire Safety Inspection. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 53035 Meriwether Way PERMIT#: FSEV2023-0004 DATE ISSUED: 3/16/2023 DESCRIPTION: MADISON CLUB – SPRING EVENTS TENT CONTRACTOR: TOWN AND COUNTRY EVENT RENTALS HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation OUTDOOR PUBLIC EVENT Air flow test SPEC. AMUSEMENT STRUCTURE Mechanical interlock TENT/CANOPY Extinguishing system PYROTECHNIC Fire alarm connection OPEN FLAME DEVICE Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.