Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FSS2017-0064
ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT ARC MECHANICAL P O BOX 1354 YUCCA VALLEY CA 92286 (760)289-9054 KFOSTERARC@GMAIL. COM BILL TO Arc Mechanical P.O. BOX 1354 Yucca Valley CA 92284 (760)289-9054 CONTRACTOR ARC MECHANICAL P.O. BOX 1354 Yucca Valley CA 92284 (760)289-9054 KFOSTERARC@GMAIL. COM OWNER HARRISON INV 90747 DIAMOND RIDGE LOOP EUGENE OR 97408 (760)289-9054 CONDITIONS Description: RESIDENTIAL FIRE SPRINKLER 13D Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 11/2/2017 ECON Parcel No: 777210030 Site Address: 53232 VIA PALACIO LA QUINTA,CA 92253 Approved: Subdivision: TR 29894-2 Block: Lot: 240 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/15/2018 RGR Valuation: $2,600.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Friday, January 27, 2023 4:44:11 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2017-0064 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING RGR 11/30/2017 11/30/2017 APPROVED FIRE FINAL**RGR 3/15/2018 3/15/2018 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY Credit Card Fee 101-0000-43505 0 $7.47 $7.47 11/2/17 WEB2050 CREDIT ARC MECHANICAL ECON Total Paid for Credit Card Fee: $7.47 $7.47 FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $156.00 $156.00 11/2/17 WEB2050 CREDIT ARC MECHANICAL ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $234.00 $234.00 11/2/17 WEB2050 CREDIT ARC MECHANICAL ECON Total Paid for FIRE FEES: $390.00 $390.00 RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $20.00 $20.00 11/2/17 WEB2050 CREDIT ARC MECHANICAL ECON Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00 $20.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 11/2/17 WEB2050 CREDIT ARC MECHANICAL ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$422.47 $422.47 Printed: Friday, January 27, 2023 4:44:11 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2017-0064 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/2/2017 EtrakitContractor Calcs Townsend Residence CALCS.pdf 1 DOC 11/2/2017 EtrakitContractor Sheet1 Townsendsheet1.pdf 1 DOC 11/2/2017 EtrakitContractor Sheet2 Townsendsheet2.pdf 1 DOC 11/2/2017 EtrakitContractor sheet3 Townsendsheet3.pdf 1 DOC 11/2/2017 EtrakitContractor sheet4 Townsendsheet4.pdf 1 BOND INFORMATION 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 11/2/2017 11/3/2017 11/3/2017 COMPLETE 1ST FIRE (2 WK)RONALD GRIESINGER 11/2/2017 11/13/2017 11/9/2017 APPROVED Printed: Friday, January 27, 2023 4:44:11 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2017-0064 TOWNSEND RESIDENCE Fire Sprinkler Reports for MASTER BEDROOM (2 SPRINKLERS) Prepared By: KIRTH FOSTER ARC MECHANICAL P.O. BOX 1354 YUCCA VALLEY, CA 92284 760-289-9054 NOVEMBER 2, 2017 Elite Software Development, Inc. TOWNSEND RESIDENCE Page 2 General Project Data Report General Data Project Title: TOWNSEND RESIDENCE Project File Name: MASTER BEDROOM..fiw Designed By: KIRTH FOSTER Date: NOVEMBER 2, 2017 Code Reference: NFPA 13D (2016) Approving Agency: Client Name: MASTER BEDROOM Phone: Address: (2 SPRINKLERS) City, State Zip Code: Company Name: ARC MECHANICAL Representative: KIRTH FOSTER Company Address: P.O. BOX 1354 City And State: YUCCA VALLEY, CA 92284 Phone: 760-289-9054 Building Name: TOWNSEND RESIDENCE Building Owner: Contact at Building: Phone at Building: Address Of Building: 53-232 VIA PALACIO City, State Zip Code: LA QUINTA, CA Project Data Description Of Hazard:RESIDENTIAL Sprinkler System Type:Wet Design Area Of Water Application: 512 ft² Maximum Area Per Sprinkler:256 ft² Default Sprinkler K-Factor:4.90 K Default Pipe Material: BLAZEMASTER CPVC Inside Hose Stream Allowance:0.00 gpm Outside Hose Stream Allowance:5.00 gpm In Rack Sprinkler Allowance:0.00 gpm Sprinkler Specifications Make:SENJU Model:RC-RES Size:1/2"Temperature Rating:162 F Water Supply Test Data Source Of Information: CVWD Test Hydrant ID: Date Of Test: 05-02-17 Hydrant Elevation: 0 ft Static Pressure: 66.02 psi Test Flow Rate: 0.00 gpm Test Residual Pressure: 0.00 psi Calculated System Flow Rate: 31.54 gpm Calculated Inflow Residual Pressure: 47.89 psi Calculation Project Data Calculation Mode:Demand HMD Minimum Residual Pressure: 7.04 psi Minimum Desired Flow Density:0.05 gpm/ft² Number Of Active Nodes:15 Number Of Active Pipes:15 Number Of Inactive Pipes:0 Number Of Active Sprinklers:2 Number Of Inactive Sprinklers:0 Elite Software Development, Inc. TOWNSEND RESIDENCE Page 3 Fire Sprinkler Input Data Node Input Data Node No. Node Description Branch Description Area Group Branch Dia. (in) Sprinkler KFactor (K) Branch Len. (ft) Pressure Estimate (psi) Branch Stnd Fittings Node Elev (ft) Branch Non- Stnd Fittings (ft) Non-Sprinkler Flow (gpm) Branch Sprk KFactor (K) 1 Sprinkler ---- ---- 0.000 4.90 0.0 7.63 ---- 12.00 0.0 0.00 0.00 2 Sprinkler ---- ---- 0.000 4.90 0.0 7.04 ---- 14.00 0.0 0.00 0.00 5 No Discharge ---- ---- 0.000 N/A 0.0 6.15 ---- 17.00 0.0 0.00 0.00 10 No Discharge ---- ---- 0.000 N/A 0.0 6.25 ---- 17.00 0.0 0.00 0.00 20 No Discharge ---- ---- 0.000 N/A 0.0 14.98 ---- 10.50 0.0 0.00 0.00 25 No Discharge ---- ---- 0.000 N/A 0.0 17.41 ---- 11.50 0.0 0.00 0.00 30 No Discharge ---- ---- 0.000 N/A 0.0 19.09 ---- 10.50 0.0 0.00 0.00 40 No Discharge ---- ---- 0.000 N/A 0.0 28.88 ---- 10.50 0.0 0.00 0.00 50 No Discharge ---- ---- 0.000 N/A 0.0 32.82 ---- 10.50 0.0 0.00 0.00 55 No Discharge ---- ---- 0.000 N/A 0.0 38.57 ---- 2.00 0.0 0.00 0.00 60 Non-Sprinkler ---- ---- 0.000 N/A 0.0 40.36 ---- 1.00 0.0 5.00 0.00 70 No Discharge ---- ---- 0.000 N/A 0.0 42.43 ---- -3.00 0.0 0.00 0.00 80 No Discharge ---- ---- 0.000 N/A 0.0 42.95 ---- -3.00 0.0 0.00 0.00 90 No Discharge ---- ---- 0.000 N/A 0.0 46.96 ---- -3.00 0.0 0.00 0.00 100 No Discharge ---- ---- 0.000 N/A 0.0 47.89 ---- -3.00 0.0 0.00 0.00 Elite Software Development, Inc. TOWNSEND RESIDENCE Page 4 Fire Sprinkler Output Data Overall Node Groupings Output Data Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. Node End. Node Type Group Flow Rate (gpm) At Beg. Node (gpm) Out (+) (gpm) In (-) (gpm) Residual Pressure (psi) Flow At Beg. Node (gpm) 1 5 0 -13.54 13.54 0.00 0.00 7.63 2 10 0 -13.00 13.00 0.00 0.00 7.04 0.00065 5 1 0 13.54 0.00 0.00 0.00 6.15 0.00000 5100 -13.54 10 2 0 13.00 0.00 0.00 0.00 6.25 -0.00063 10 5 0 13.54 10 20 0 -26.54 20 10 0 26.54 0.00 0.00 0.00 14.98 0.00000 20 30 0 -13.86 20 25 0 -12.68 25 20 0 12.68 0.00 0.00 0.00 17.41 0.00000 25 30 0 -12.68 30 20 0 13.86 0.00 0.00 0.00 19.09 0.00000 30 25 0 12.68 30 40 0 -26.54 40 30 0 26.54 0.00 0.00 0.00 28.88 0.00000 40 50 0 -26.54 50 40 0 26.54 0.00 0.00 0.00 32.82 0.00000 50 55 0 -26.54 55 50 0 26.54 0.00 0.00 0.00 38.57 0.00000 55 60 0 -26.54 60 55 0 26.54 0.00 5.00 0.00 40.36 0.00000 60 70 0 -31.54 70 60 0 31.54 0.00 0.00 0.00 42.43 0.00000 70 80 0 -31.54 80 70 0 31.54 0.00 0.00 0.00 42.95 -0.03046 80 90 0 -31.57 90 80 0 31.57 0.00 0.00 0.00 46.96 0.03046 90 100 0 -31.54 100 90 0 31.54 0.00 0.00 -31.54 47.89 Elite Software Development, Inc. TOWNSEND RESIDENCE Page 5 Fire Sprinkler Output Data Overall Pipe Output Data Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 1 4.90 12.00 13.54 7.63 1.00 13.54 0.03306 6.58 0.680 5 0.00 17.00 0.00 6.15 1.101 13.54 2E 14.00 -2.165 BLAZEMASTER CPVC 150 4.56 0 20.58 -1.485 2 4.90 14.00 13.00 7.04 1.00 13.00 0.03068 4.58 0.509 10 0.00 17.00 0.00 6.25 1.101 13.00 ET 12.00 -1.299 BLAZEMASTER CPVC 150 4.38 0 16.58 -0.790 5 0.00 17.00 0.00 6.15 1.00 0.00 0.03306 2.08 0.102 10 0.00 17.00 0.00 6.25 1.101 13.54 ----- 1.00 0.000 BLAZEMASTER CPVC 150 4.56 0 3.08 0.102 10 0.00 17.00 0.00 6.25 1.00 0.00 0.11487 28.50 5.916 20 0.00 10.50 0.00 14.98 1.101 26.54 2ET 23.00 2.815 BLAZEMASTER CPVC 150 8.94 0 51.50 8.730 20 0.00 10.50 0.00 14.98 1.00 12.68 0.02930 58.75 2.864 25 0.00 11.50 0.00 17.41 1.101 12.68 4ET 39.00 -0.433 BLAZEMASTER CPVC 150 4.27 0 97.75 2.431 20 0.00 10.50 0.00 14.98 1.00 13.86 0.03452 77.00 4.108 30 0.00 10.50 0.00 19.09 1.101 13.86 4ET 42.00 0.000 BLAZEMASTER CPVC 150 4.67 0 119.00 4.108 25 0.00 11.50 0.00 17.41 1.00 0.00 0.02930 21.42 1.243 30 0.00 10.50 0.00 19.09 1.101 12.68 2ET 21.00 0.433 BLAZEMASTER CPVC 150 4.27 0 42.42 1.676 30 0.00 10.50 0.00 19.09 1.00 0.00 0.11487 66.25 9.793 40 0.00 10.50 0.00 28.88 1.101 26.54 ET 19.00 0.000 BLAZEMASTER CPVC 150 8.94 0 85.25 9.793 40 0.00 10.50 0.00 28.88 1.00 0.00 0.11487 23.25 3.934 50 0.00 10.50 0.00 32.82 1.101 26.54 E 11.00 0.000 BLAZEMASTER CPVC 150 8.94 0 34.25 3.934 50 0.00 10.50 0.00 32.82 1.00 0.00 0.11487 8.50 2.079 55 0.00 2.00 0.00 38.57 1.101 26.54 C 9.60 3.681 BLAZEMASTER CPVC 150 8.94 0 18.10 5.760 55 0.00 2.00 0.00 38.57 1.00 0.00 0.16274 2.00 1.351 60 0.00 1.00 5.00 40.36 1.025 26.54 ET 6.30 0.433 TYPE L COPPER 150 10.32 0 8.30 1.784 60 0.00 1.00 5.00 40.36 1.50 5.00 0.03450 6.00 0.342 70 0.00 -3.00 0.00 42.43 1.505 31.54 EG 3.90 1.732 TYPE L COPPER 150 5.69 0 9.90 2.074 Elite Software Development, Inc. TOWNSEND RESIDENCE Page 6 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 70 0.00 -3.00 0.00 42.43 2.00 0.00 0.00771 60.00 0.519 80 0.00 -3.00 0.00 42.95 2.047 31.54 E 7.22 0.000 SCH. 40 PVC 150 3.07 0 67.22 0.519 80 Meter -3.00 42.95 31.57 90 4.00 psi -3.00 46.96 90 0.00 -3.00 0.00 46.96 1.50 0.00 0.03450 20.00 0.925 100 0.00 -3.00 0.00 47.89 1.505 31.54 TG 6.80 0.000 TYPE K COPPER 150 5.69 0 26.80 0.925 Fitting Legend: F = 45 Degree Elbow, E = 90 Degree Elbow, L = Long Turn Elbow, T = Tee or Cross, B = Butterfly Valve, G = Gate Valve, C = Check Valve Elite Software Development, Inc. TOWNSEND RESIDENCE Page 7 Fire Sprinkler Output Data Overall Sprinkler Output Data Flowing Sprinkler Node No. Area Group Code Sprinkler KFactor (K) Sprinkler Elevation (feet) Residual Pressure (psi) Flowing Area (ft²) Flowing Density (gpm/ft²) Sprinkler Discharge (gpm) 1 4.90 12.00 7.63 256.00 0.053 13.54 Sub Totals For Non-Group 256.00 0.053 13.54 2 4.90 14.00 7.04 256.00 0.051 13.00 Sub Totals For Non-Group 256.00 0.051 13.00 Totals For All Groups 512.00 0.052 26.54 Elite Software Development, Inc. TOWNSEND RESIDENCE Page 8 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number:2 HMD Actual Residual Pressure:7.04 psi HMD Actual GPM:13.00 gpm Sprinkler Summary Sprinkler System Type:Wet Specified Area Of Application:512.00 ft² Minimum Desired Density:0.050 gpm/ft² Application Average Density:0.052 gpm/ft² Application Average Area Per Sprinkler:256.00 ft² Sprinkler Flow:26.54 gpm Average Sprinkler Flow:13.27 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity ( In Pipe 55 - 60 )10.32 ft/sec Maximum Velocity Pressure ( In Pipe 55 - 60 )0.72 psi Allowable Maximum Nodal Pressure Imbalance:0.0100 psi Actual Maximum Nodal Pressure Imbalance:0.0064 psi Actual Average Nodal Pressure Imbalance:0.0012 psi Actual Maximum Nodal Flow Imbalance:0.0305 gpm Actual Average Nodal Flow Imbalance:0.0041 gpm Overall Network Summary Number Of Unique Pipe Sections:15 Number Of Flowing Sprinklers:2 Pipe System Water Volume:27.43 gal Sprinkler Flow:26.54 gpm Non-Sprinkler Flow:5.00 gpm Minimum Required Residual Pressure At System Inflow Node:47.89 psi Demand Flow At System Inflow Node:31.54 gpm Page:1 of 8 Document No.U085161 Date:Oct/06/2016 Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar1/2) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents’ escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. “Lead Free” is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA’s Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Page:2 of 8 Document No.U085161 Date:Oct/06/2016 TECHNICAL DATA Approvals: cULus Listed, NSF-61-G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (12.1bar) Discharge Coefficient (Nominal K-Factor): K=4.9 GPM/psi1/2 (70.6 LPM/bar1/2) Temperature Rating: 162℉ (72℃) Sprinkler with 140℉ (60℃) Cover Plate 175℉ (79℃) Sprinkler with 162℉ (72℃) Cover Plate Color Code (Sprinkler) 162℉ (72℃): Uncolored 175℉ (79℃): White Color Code (Cover Plate) 140℉ (60℃): No Mark 162℉ (72℃): White‐Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figure 1 OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart. This leads to allow the water flow to be distributed on the affected by fire area. (Ref. Figure 2) FIGURE 2. OPERATION PROCESS (The figure is for illustrative purpose only) FIGURE 1. Model RC-RES K=4.9 FIGURE 1-1. Marking (Color Code) Page:3 of 8 Document No.U085161 Date:Oct/06/2016 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D or 13R for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: (1) Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. (2) Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) – Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of “design sprinklers” as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the followings; ・ The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. Page:4 of 8 Document No.U085161 Date:Oct/06/2016 ・ A minimum discharge 0.1GPM/sq.ft. [4.07LPM/sq.m] over the “design area” comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 Ordinary Temperature Rating 162℉ (72℃) Intermediate Temperature Rating 175℉ (79℃) Maximum Coverage Area(a) Ft. × Ft. (m ×m) Maximum Spacing Ft. (m) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) 12×12 (3.7×3.7) 12 (3.7) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 14×14 (4.3×4.3) 14 (4.3) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 16×16 (4.9×4.9) 16 (4.9) 13 (49.2) 7.0 (0.48) 14 (53.0) 8.2 (0.57) 18×18 (5.5×5.5) 18 (5.5) 17 (64.3) 12.0 (0.83) 18 (68.1) 13.5 (0.93) 20×20 (6.1×6.1) 20 (6.1) 21 (79.5) 18.4 (1.27) ― ― Smooth Ceilings 3/8 to 7/8 Inches. Beamed Ceilings per NFPA 13D,13R or 13 Installed in beam 3/8 to 7/8 inches below bottom of beam. Concealed 8 (2.4) (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM/LPM from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. (c) For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Page:5 of 8 Document No.U085161 Date:Oct/06/2016 Use a torque of 7 to 14 ft.lbs (9.5 to 19.0Nm) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not force to rotate the Cap Remover RC to the left when placing the two hook arms into place. The installed sprinkler may become loosened, which may cause water leakage. Installing Procedure Step 1 The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the “Tolerance Limit of Ceiling Level” indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). FIGURE 3. INSTALLATION FIGURE 4 Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Page:6 of 8 Document No.U085161 Date:Oct/06/2016 FIGURE 5. PROTECTIVE CAP REMOVAL FIGURE 6 FIGURE 7. INSTALLATION (CORRECT OR INCORRECT) Page:7 of 8 Document No.U085161 Date:Oct/06/2016 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40℉ / 4℃ to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 100℉ / 38℃. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A “Hydraulic Design Criteria”). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Page:8 of 8 Document No.U085161 Date:Oct/06/2016 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Specify, Temp. and Finish). Sprinkler: Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162℉ (72℃) or 175℉ (79℃) ) Cover Plate Assembly: 2-5/8 inch (φ68mm) or 3-1/4 inch (φ83mm) or 2-5/8 inch square (□68mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Wood grain Custom Color Custom Pattern 2-5/8" Round, 140ºF ○ ○ - - - ○ - ○ ○ 3-1/4" Round, 140ºF ○ ○ ○ ○ ○ ○ ○ ○ ○ 2-5/8" Square, 140ºF ○ - - - - - - ○ ○ 2-5/8" Round, 162ºF ○ - - - - - - ○ ○ 3-1/4" Round, 162ºF ○ - - - - - - ○ ○ Tools for Installation of Model: RC-RES ・Socket for Model RC-RES ・Wrench & Socket for Model RC-RES ・Cap Remover RC Worldwide Contacts www.tyco-fire.com Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage Page 1 of 10 MARCH 2013 TFP171 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprin- klers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a • A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2 ˝ NPT TY1231: Pendent 2.8K, 1/2 ˝ NPT TY2131: Upright 4.2K, 1/2 ˝ NPT TY2231: Pendent 4.2K, 1/2 ˝ NPT TY3131: Upright 5.6K, 1/2 ˝ NPT TY3231: Pendent 5.6K, 1/2 ˝ NPT TY4131: Upright 8.0K, 3/4 ˝ NPT TY4231: Pendent 8.0K, 3/4 ˝ NPT TY4831: Upright* 8.0K, 1/2 ˝ NPT TY4931: Pendent* 8.0K, 1/2 ˝ NPT *Eastern Hemisphere Sales Only TFP171 Page 2 of 10 *** * ** * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 7/16" (11,1 mm) NOMINAL MAKE-IN ESCUTCHEON PLATE SEATING SURFACE STYLE 10 or 20 RECESSED ESCUTCHEON Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. WRENCH FLATS 2-3/16" (55,6 mm) Sealing Assembly Compression Screw 1 2 Button Frame - - Bulb 3 - 4 -6 -Deector 5 - 7 Bushing- 1/2" NPT 6 5 1 4 2 3 7 2-7/8" (73,0 mm) DIA. 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ** *** * * UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION 7/16" (11,1 mm) NOMINAL MAKE-IN ESCUTCHEON PLATE SEATING SURFACE STYLE 10 or 20 RECESSED ESCUTCHEON Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. WRENCH FLATS 2-3/16" (55,6 mm) 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) Sealing Assembly Compression Screw 1/2" NPT Frame Button-2 1 - Deector6- 2-7/8" (73,0 mm) DIA. 6 4 5 2 1 3 4 -Bulb 3 -5 - FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 3 of 10 *** ** * * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 7/16" (11,1 mm) NOMINAL MAKE-IN ESCUTCHEON PLATE SEATING SURFACE STYLE 10 or 20 RECESSED ESCUTCHEON Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. 2-7/8" (73,0 mm) DIA.1/2" NPT 1 2 Button Frame - - Bulb4-6 -Deector 5 6 4 2 3 1 3 -5 - WRENCH FLATS 2-3/16" (55,6 mm) 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) Sealing Assembly Compression Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT *** ** * * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 1/2" (12,7 mm) NOMINAL MAKE-IN ESCUTCHEON PLATE SEATING SURFACE STYLE 30 or 40 RECESSED ESCUTCHEON Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. WRENCH FLATS Sealing Assembly Compression Screw 3/4" NPT 1 2 Button Frame - - Bulb 3 - 4 -6 -Deector 5 - 5 6 4 2 3 1 2-7/8" (73,0 mm) DIA. 2-5/16" (58,7 mm) 1-9/16" (39,7 mm) 2-1/4" (57,2 mm) FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT TFP171 Page 4 of 10 Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi1/2 (40,3 LPM/bar1/2) K=4.2 GPM/psi1/2 (60,5 LPM/bar1/2) K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) K=8.0 GPM/psi1/2 (115,2 LPM/bar1/2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly . . . . . . . . .Beryllium Nickel w/TEFLON Bulb ......................Glass Compression Screw . . . . . . . . Bronze Deflector ...........Copper/Bronze Bushing (K=2.8) . . . . . . . . . . . Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprinklers are intended for fire protection sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the require- ments of FM’s Loss Prevention Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklersmust be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint shold be obtained by applying a min- imum to maximum torque of 7 to 14 ft.l-bs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening * ** ** * * PENDENTUPRIGHT CROSS SECTION 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) 2-3/16" (55,6 mm) Sealing Assembly WRENCH FLATS Compression Screw Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. CEILING PLATE SEATING SURFACE 7/16" (11,1 mm) NOMINAL MAKE-IN 1 2 Button Frame - - Bulb 3 - 4 - 6 -Deector 5 - 1/2" NPT 5 6 4 2 3 1 FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With refer- ence to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprin- kler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step C. After ceiling installation and finishing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED SIGNAL*** WHITE 2.8 1/2” NPT PENDENT (TY1231) and UPRIGHT (TY1131) 135°F (57°C)Orange 1, 2, 3, 4 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY1231)* Figure 6 135°F (57°C)Orange 1, 2, 4 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green RECESSED PENDENT (TY1231)** Figure 7 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 4.2 1/2” NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F (57°C)Orange 1, 2 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY2231)* Figure 8 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green RECESSED PENDENT (TY2231)** Figure 9 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2” NPT) or Style 40 (3/4” NPT) 3/4” Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2” NPT) or Style 30 (3/4” NPT) 1/2” Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED SIGNAL*** WHITE LEAD COATED 5.6 1/2” NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F (57°C)Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY3231)* Figure 10 135°F (57°C)Orange 1, 2, 4, 5 N/A 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY3231)** Figure 11 135°F (57°C)Orange 1, 2, 3, 4, 5 N/A 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 8.0 3/4” NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F (57°C)Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY4231)* Figure 12 135°F (57°C)Orange 1, 2, 5 N/A 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY4231)** Figure 13 135°F (57°C)Orange 1, 2, 3, 5 N/A 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 8.0 1/2” NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F (57°C)Orange 1, 2, 4, 5, 6 1, 2, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2” NPT) or Style 40 (3/4” NPT) 3/4” Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2” NPT) or Style 30 (3/4” NPT) 1/2” Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. SPRINKLER FINISH K FACTOR TYPE NATURAL BRASS CHROME PLATED SIGNAL WHITE LEAD COATED 2.8 1/2” NPT PENDENT (TY1231) and UPRIGHT (TY1131)175 PSI (12,1 BAR)N/A RECESSED PENDENT (TY1231) 4.2 1/2” NPT PENDENT (TY2231) and UPRIGHT (TY2131)175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) 5.6 1/2” NPT PENDENT (TY3231) and UPRIGHT (TY3131) 250 PSI (17,2 BAR) OR 175 PSI (12,1 BAR) (SEE NOTE 1) 175 PSI (12,1 BAR) RECESSED PENDENT (TY3231)N/A 8.0 3/4” NPT PENDENT (TY4231) and UPRIGHT (TY4131)175 PSI (12,1 BAR) 175 PSI (12,1 BAR) RECESSED PENDENT (TY4231)N/A 8.0 1/2” NPT PENDENT (TY4931) and UPRIGHT (TY4831)175 PSI (12,1 BAR)175 PSI (12,1 BAR) NOTES:1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE TFP171 Page 8 of 10 2-1/4" DIA. (57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING MOUNTING PLATE 1/8" (3,2 mm) SERIES TY-FRBCLOSURE 13/16" (20,6 mm) 1-5/16" (33,3 mm) 1/4" (6,4 mm) 3/4" (19,1 mm)5/8±1/4" (15,9±6,4 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 1/2±1/8" (12,7±3,2 mm)2-1/4" DIA. (57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE CLOSURE FACE OF SPRINKLER FITTING 1-1/16" (27,0 mm) 1-5/16" (33,3 mm) MOUNTING PLATE 1/8" (3,2 mm) 1/4" (6,4 mm) 1/2" (12,7 mm) SERIES TY-FRB FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-1/4" DIA. (57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING MOUNTING PLATE 1/8" (3,2 mm) SERIES TY-FRB 5/8±1/4" (15,9±6,4 mm) CLOSURE 3/4" (19,1 mm) 1-1/4" (31,8 mm) 1/4" (6,4 mm) 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 1/2±1/8" (12,7±3,2 mm)2-1/4" DIA. (57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING MOUNTING PLATE 1/8" (3,2 mm) SERIES TY-FRBCLOSURE 1" (25,4 mm) 1-1/4" (31,8 mm) 1/4" (6,4 mm) 1/2" (12,7 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 9 of 10 2-1/4" DIA. (57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING MOUNTING PLATE 1/8" (3,2 mm) SERIES TY-FRB 5/8±1/4" (15,9±6,4 mm) CLOSURE 3/4" (19,1 mm) 1-1/4" (31,8 mm) 1/4" (6,4 mm) 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 1/2±1/8" (12,7±3,2 mm)2-1/4" DIA. (57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING MOUNTING PLATE 1/8" (3,2 mm) SERIES TY-FRBCLOSURE 1" (25,4 mm) 1-1/4" (31,8 mm) 1/4" (6,4 mm) 1/2" (12,7 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-1/4" DIA. (57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING MOUNTING PLATE 1/8" (3,2 mm) SERIES TY-FRB 5/8±1/4" (15,9±6,4 mm) CLOSURE 1-5/16" (33,3 mm) 13/16" (20,6 mm) 3/4" (19,1 mm) 1/4" (6,4 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 1/2±1/8" (12,7±3,2 mm)2-1/4" DIA. (57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING MOUNTING PLATE 1/8" (3,2 mm) SERIES TY-FRB CLOSURE 1-5/16" (33,3 mm) 1-1/16" (27,0 mm) 1/2" (12,7 mm) 1/4" (6,4 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP171 Page 10 of 10 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION P/N 57 – XXX – X – XXX SPRINKLER FINISH 1 NATURAL BRASS 3 PURE WHITE (RAL9010)* 4 SIGNAL WHITE (RAL9003) 7 LEAD COATED 9 CHROME PLATED X JET BLACK (RAL9005)** TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) SIN 330 2.8K UPRIGHT (1/2”NPT)TY1131 331 2.8K PENDENT (1/2”NPT)TY1231 340 4.2K UPRIGHT (1/2”NPT)TY2131 341 4.2K PENDENT (1/2”NPT)TY2231 370 5.6K UPRIGHT (1/2”NPT)TY3131 371 5.6K PENDENT (1/2”NPT)TY3231 390 8.0K UPRIGHT (3/4”NPT)TY4131 391 8.0K PENDENT (3/4”NPT)TY4231 360 8.0K UPRIGHT (1/2”NPT)TY4831* 361 8.0K PENDENT (1/2”NPT)TY4931* * Eastern Hemisphere sales only. ** Available in only 2.8K, 4.2K, and 8.0K, 155°F (68°C) and 200°F (93°C); requires lead time to manufacture. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread ConnectionsSpecify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) tempera- ture rating, (specify) finish or coating, P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*). Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. * Refer to Technical Data Sheet TFP770.