Loading...
FSS2018-0097ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT CHARLES F BROWN FIRE PROTECTION DESIGN 21386 LILIUM COURT MORENO VALLEY CA 92557 (951)712-4959 CHUCK92234@AOL.CO M BILL TO CHARLES F BROWN FIRE PROTECTION DESIGN 21386 LILIUM COURT MORENO VALLEY CA 92557 (951)712-4959 CHUCK92234@AOL.CO M CONTRACTOR CHARLES F BROWN FIRE PROTECTION DESIGN 21386 LILIUM COURT MORENO VALLEY CA 92557 (951)712-4959 CHUCK92234@AOL.CO M CONDITIONS Description: CORONEL / SFD SPRINKLER Type: FIRE SPRINKLER Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 6/6/2018 SSW Parcel No: 773233007 Site Address: 52140 AVENIDA MENDOZA LA QUINTA,CA 92253 Approved: 7/12/2018 RCA Subdivision: SANTA CARMELITA VALE LA QUINTA UNIT 11 Block: 94 Lot: 16 Issued: 7/16/2018 SSW Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 10/11/2018 EGO Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 1.) Show underground detail with water meter size and node points on plan. 2.) Show scaled dimensions of pipe lengths on plan. 3.) Add fire sprinkler protection in FAU Room. Fire sprinkler head to be intermediate temperature. 4.) Show hanger location on plan. Several pipe areas on plans are lacking hangers. 5.) Provide water meter cut sheet for review. 6.) Show 10% safety margin on hydraulic calculations. PLANS WERE APPROVED PER EG ON 7/12/18. I CHANGED STATUS TO APPROVED AND ADJUSTED DATE TO MATCH. Printed: Friday, January 27, 2023 9:51:37 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0097 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL OWNER DARIO SANCHEZ 417 VIA MALAGA REDONDO BEACH CA 0 (951)712-4959 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD HYRO EGO 7/16/2018 7/16/2018 APPROVED OVERHEAD ROUGH PIPING EGO 7/16/2018 7/16/2018 APPROVED FIRE FINAL**EGO 9/27/2018 9/27/2018 NOT READY FIRE FINAL**EGO 10/11/2018 10/11/2018 APPROVED PARENT PROJECTS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $156.00 $156.00 6/6/18 R36215 4665 CHECK CHARLES F BROWN FIRE PROTECTIO SSW Total Paid for FIRE FEES: $156.00 $156.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 6/6/18 R36215 4665 CHECK CHARLES F BROWN FIRE PROTECTIO SSW Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/6/18 R36215 4665 CHECK CHARLES F BROWN FIRE PROTECTIO SSW Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$171.00 $171.00 Printed: Friday, January 27, 2023 9:51:37 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0097 REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) STEPHANIE SWANSTROM 6/6/2018 6/7/2018 6/13/2018 COMPLETE 1ST FIRE (2 WK)EDGAR GONZALEZ 6/13/2018 6/18/2018 6/19/2018 REVISIONS REQUIRED 1.) Show underground detail with water meter size and node points on plan. 2.) Show scaled dimensions of pipe lengths on plan. 3.) Add fire sprinkler protection in FAU Room. Fire sprinkler head to be intermediate temperature. 4.) Show hanger location on plan. Several pipe areas on plans are lacking hangers. 5.) Provide water meter cut sheet for review. 6.) Show 10% safety margin on hydraulic calculations. 2ND FIRE (2 WK)EDGAR GONZALEZ 6/28/2018 7/12/2018 7/12/2018 APPROVED- CONDITIONS The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Printed: Friday, January 27, 2023 9:51:37 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0097 ATTACHMENTS BOND INFORMATION Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777-7000. SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is subject to field inspection. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Edgar Gonzalez - Fire Safety Specialist Printed: Friday, January 27, 2023 9:51:37 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0097