Loading...
FSS2018-0103ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT CHARLES F BROWN FIRE PROTECTION DESIGN 21386 LILIUM COURT MORENO VALLEY CA 92557 CHUCK92234@AOL.CO M BILL TO CHARLES F BROWN FIRE PROTECTION DESIGN 21386 LILIUM COURT MORENO VALLEY CA 92557 CHUCK92234@AOL.CO M CONTRACTOR CHARLES F BROWN FIRE PROTECTION DESIGN 21386 LILIUM COURT MORENO VALLEY CA 92557 CHUCK92234@AOL.CO M OWNER TIMOTHY HALL 44474 W NEES AVE FIREBAUGH CA 0 CONDITIONS Description: DEWEY / BRES2017-0261 / FIRE SPRINKLER Type: FIRE SPRINKLER Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 6/19/2018 RCA Parcel No: 777370013 Site Address: 52935 VIA SAVONA LA QUINTA,CA 92253 Approved: 7/12/2018 AMA Subdivision: TR 29894-3 Block: Lot: 26 Issued: 7/16/2018 SSW Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 1/28/2019 EGO Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Wednesday, August 23, 2023 10:50:22 AM 1 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0103 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING EGO 8/8/2018 8/8/2018 DISAPPROVE D Fire sprinkler head coverage was missing in 4 separate areas. OVERHEAD HYRO EGO 8/8/2018 8/8/2018 DISAPPROVE D Fire sprinkler head coverage was missing in 4 separate areas. OVERHEAD ROUGH PIPING EGO 8/13/2018 8/13/2018 APPROVED OVERHEAD HYRO EGO 8/13/2018 8/13/2018 APPROVED FIRE FINAL**EGO 1/7/2019 1/7/2019 DISAPPROVE D NO RELIABLE WATER SOURCE AT TIME OF INSPECTION. FIRE FINAL**EGO 1/24/2019 1/28/2019 APPROVED DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $156.00 $156.00 6/19/18 R36694 4677 CHECK CHARLES F BROWN FIRE PROTECTIO AHI FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $234.00 $234.00 6/19/18 R36694 4677 CHECK CHARLES F BROWN FIRE PROTECTIO AHI Total Paid for FIRE FEES: $390.00 $390.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 6/19/18 R36694 4677 CHECK CHARLES F BROWN FIRE PROTECTIO AHI Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/19/18 R36694 4677 CHECK CHARLES F BROWN FIRE PROTECTIO AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$405.00 $405.00 Printed: Wednesday, August 23, 2023 10:50:22 AM 2 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0103 REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) REYNA CAMARENA 6/19/2018 6/19/2018 6/19/2018 COMPLETE 1ST FIRE (2 WK)EDGAR GONZALEZ 6/19/2018 7/4/2018 7/3/2018 REVISIONS REQUIRED FIRE SPRINKLER SYSTEM PLAN REVIEW - REVISIONS REQUIRED: The Riverside County Fire Department – City of La Quinta Fire Marshal’s Office has reviewed your submitted plans and the following corrections addressed before approval is granted: 1.) Head legend indicates globe fire sprinkler heads are being used for install, yet no cut sheets were provided for such heads. Please provide appropriate cut sheets to review minimum operating pressure/flow or correct head legend to specify what fire sprinkler head will be used. Maybe reliable fire sprinklers? 2.) Show underground detail on plan along with pipe length, pipe diameter, and node points. This will be required to verify fiction loss form source to fire riser. Water meter node point need to be shown as well (MTR1 and 2). The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be PARENT PROJECTS Printed: Wednesday, August 23, 2023 10:50:22 AM 3 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0103 BOND INFORMATION 2ND FIRE - ETRAKIT (1 WK) EDGAR GONZALEZ 7/6/2018 7/13/2018 7/12/2018 APPROVED- CONDITIONS witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777-7000. SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is subject to field inspection. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Edgar Gonzalez - Fire Safety Specialist 3RD FIRE (2 WK)EDGAR GONZALEZ 8/9/2018 8/23/2018 8/23/2018 APPROVED- CONDITIONS REVISION TO FSS CONDITIONS TO REMAIN. Printed: Wednesday, August 23, 2023 10:50:22 AM 4 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0103 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 1/3/2022 JULIA AGGREH Hydraulic Cal Master Bedrm with notes 8 9 18.pdf Hydraulic Cal Master Bedrm with notes 8 9 18.pdf 0 DOC 1/3/2022 JULIA AGGREH Hydraulic Cal Master Bedroom 8 9 18.pdf Hydraulic Cal Master Bedroom 8 9 18.pdf 0 DOC 1/3/2022 JULIA AGGREH Inspection Log FSS2018- 0103 8 8 18.pdf Inspection Log FSS2018- 0103 8 8 18.pdf 0 DOC 1/3/2022 JULIA AGGREH Residential Connection Charge Estimate.pdf Residential Connection Charge Estimate.pdf 0 DOC 1/3/2022 JULIA AGGREH FSS2018-0103 PLAN 52935 1st FL Via Savona_Rev 1.pdf FSS2018-0103 PLAN 52935 1st FL Via Savona_Rev 1.pdf 0 DOC 1/3/2022 JULIA AGGREH FSS2018-0103 PLAN 52935 2nd FL Via Savona_2nd.pdf FSS2018-0103 PLAN 52935 2nd FL Via Savona_2nd.pdf 0 Printed: Wednesday, August 23, 2023 10:50:22 AM 5 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0103