Loading...
FSS2018-0108ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT MARK TRELAK /DESERT FIRE EXTINGUISHER CO INC P O BOX 1607 PALM SPRINGS CA 92263 (760)322-0995 MARK@DESERT- FIRE.COM BILL TO DESERT FIRE EXTINGUISHER CO INC P O BOX 1607 PALM SPRINGS CA 92263 (760)322-0995 MARK@DESERT- FIRE.COM CONTRACTOR DESERT FIRE EXTINGUISHER CO INC P O BOX 1607 PALM SPRINGS CA 92263 (760)322-0995 MARK@DESERT- FIRE.COM CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE ARMANDO MAGALLON 7/17/2018 7/17/2018 PERMIT AND JOB CARD ISSUED PLAN CHECK PICKED UP ARMANDO MAGALLON 7/5/2018 7/5/2018 APPLICANT PICKED UP 3 SETS OF PLANS AND CUTSHEETS RESUBMITTAL STEPHANIE SWANSTROM 7/11/2018 7/11/2018 CONDITIONS Description: PGA / MULTI USE BUILDING Type: FIRE SPRINKLER Subtype: COMMERCIAL/INDUSTRIAL Status: FINALED Applied: 6/29/2018 AHI Parcel No: 775220027 Site Address: 55955 PGA BLVD LA QUINTA,CA 92253 Approved: 7/16/2018 EGO Subdivision: PM 24995 Block: Lot: 4 Issued: 7/17/2018 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 11/9/2018 EGO Valuation: $0.00 Occupancy Type: Construction Type: Expired: 5/8/2019 EGO No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Wednesday, January 18, 2023 4:40:14 PM 1 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0108 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FIRE FINAL**EGO APPROVED OVERHEAD ROUGH PIPING EGO 7/23/2018 7/24/2018 APPROVED W/EXCEPTIO N AS BUILT DRAWINGS TO BE SUBMITTED BEFORE FINAL. OVERHEAD HYRO EGO 7/23/2018 7/23/2018 APPROVED W/EXCEPTIO N AS BUILT DRAWINGS TO BE SUBMITTED BEFORE FINAL INSPECTION. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS COMMERCIAL/INDUSTR IAL 101-0000-42421 0 $234.00 $234.00 6/29/18 R37044 354 CHECK DESRT FIRE EXTINGUISHER AHI FIRE SPRINKLER SYSTEMS COMMERCIAL/INDUSTR IAL PC 101-0000-42420 0 $390.00 $390.00 6/29/18 R37044 354 CHECK DESRT FIRE EXTINGUISHER AHI Total Paid for FIRE FEES: $624.00 $624.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 6/29/18 R37044 354 CHECK DESRT FIRE EXTINGUISHER AHI Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/29/18 R37044 354 CHECK DESRT FIRE EXTINGUISHER AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$639.00 $639.00 Printed: Wednesday, January 18, 2023 4:40:14 PM 2 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0108 UG HYDRO EGO 10/25/2018 10/25/2018 APPROVED W/EXCEPTIO N FLUSH EGO 10/25/2018 10/25/2018 APPROVED W/EXCEPTIO N CORRECTIONS WRITTEN AND ISSUED TO CONTRACTOR. FIRE FINAL**EGO 11/9/2018 11/9/2018 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST FIRE (2 WK)EDGAR GONZALEZ 6/18/2018 7/2/2018 7/2/2018 REVISIONS REQUIRED PERMIT WAS APPLIED FOR ON 6/18/2018 AND NOT PROCESSED BY TECH APPLICANT CAME IN TO CHECK STATUS AND DISCOVERED MISTAKE. INFORMED APPLICANT WILL LET REVIEWER KNOW OF MISTAKE AND TRY TO EXPIDITE PARENT PROJECTS Printed: Wednesday, January 18, 2023 4:40:14 PM 3 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0108 1ST FIRE (2 WK)EDGAR GONZALEZ 6/18/2018 7/2/2018 7/2/2018 REVISIONS REQUIRED FIRE SPRINKLER - PLAN REVIEW - REVISIONS REQUESTED.The Riverside County Fire Department – City of La Quinta Fire Marshal’s Office has reviewed your submitted plans and the following corrections addressed before approval is granted:1.) Provide elevation plan for building.2.) Pipe lengths are not shown on floor plan. Please show pipe lengths in order to verify hydraulic calculations.3.) Note of building's details is not shown on plan. Provide building construction classification and square footage and occupancy classification for reference.4.) System's remote calculated area is not identified on plan. Please provide for reference on floor plan.5.) Fire flow test is not within a year's date. Only fire flow tests that were conducted within a year from current date will be taken. Please provide an updated fire flow report with a map locating fire hydrants that were utilized for testing for reference. 6.) Show fire sprinkler head spacing on plan.7.) Identify pipe diameter size from node point TR to 55. (Hydraulic calculations show 4'') 8.) Upright fire sprinklers for concealed spaces show 155 degree temperature heads. Please revise with an intermediate temperature fire sprinkler head or clarify.9.) Please note that underground fire service main plans/permit have not been submitted/approved. If underground fire main plans differ from the floor plan that was submitted, a resubmittal to this plan shall be provided upon field inspection. 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 6/29/2018 7/2/2018 7/2/2018 FIRE SPRINKLER SYSTEM - CONDITIONS OF APPROVAL. Printed: Wednesday, January 18, 2023 4:40:14 PM 4 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0108 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department – Office of the Fire Marshal personnel and are approved with the following conditions: Underground Fire Service Main Conditions: The following inspections and tests must be observed: 1) Pre-Pour Thrust Block cutout inspection 2) Rough Piping – Confirm pipe material, bury depth and backfill requirements 3) Hydrostatic Test – a. Minimum 200 psi for two (2) hours or at 50 psi in excess of the maximum static pressure when it is in excess of 150 psi. 4) Underground Flush & Final - a. Flush of the underground supply line until clear of all debris and to the satisfaction of the inspector. b. The underground flush shall be done through a pipe or hose equal in size to the sprinkler underground supply pipe, prior to connection to the above ground sprinkler piping. c. Appropriate valve and connection signage is provided Printed: Wednesday, January 18, 2023 4:40:14 PM 5 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0108 2ND FIRE (2 WK)EDGAR GONZALEZ 7/11/2018 7/25/2018 7/16/2018 APPROVED- CONDITIONS d. Private fire hydrants are painted red and provided with OSFM tag. e. Provide the completed Contractor’s Material and Test Certificate for Underground Pipe Fire Sprinkler System Conditions: 1) Approval of these plans does not include the piping of the underground system. Installing contractor shall provide separate underground plans for review and approval prior to installation. 2) The completed Contractor’s Material and Test Certificate for Aboveground Piping shall be provided to the fire inspector prior to a final inspection. 3) Permanently marked identification signs shall be attached to all control valves. 4) A sign shall be located adjacent to the alarm bell worded as follows: a) SPRINKLER FIRE ALARM - WHEN BELL RINGS CALL 911 5) Provide for 24 hour monitoring of the sprinkler alarm system. 6) The following inspections/tests are required to be witnessed by Office of the Fire Marshal staff: Printed: Wednesday, January 18, 2023 4:40:14 PM 6 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0108 a) Overhead Rough: All installed/relocated piping must be visible. b) Overhead Hydro: Entire system shall be hydrostatically tested at a minimum of 200 psi for 2 hours. c) Underground Supply Flush: Flush of the underground supply line until clear of all debris and to the satisfaction of the inspector. d) Final inspection: Water-flow signal test as performed from the inspector test valve. As-Built plans required to be maintained on site as approved by the inspector. General Information sign and Hydraulic Calculation plate(s) affixed to riser and engraved with information in a permanent fashion. Title 19 “New” system tag affixed to riser. NOTE: The underground flush shall be done through a pipe or hose equal in size to the sprinkler underground supply pipe, prior to connection to the above ground sprinkler piping. The Fire Department approved plans, job card and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777-7000. Printed: Wednesday, January 18, 2023 4:40:14 PM 7 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0108 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/15/2018 EDGAR GONZALEZ FSS2018-0108 PGA FIRE SPRINKLER UG HOLD HARMLESS.pdf FSS2018-0108 PGA FIRE SPRINKLER UG HOLD HARMLESS.pdf 1 DOC 11/15/2018 EDGAR GONZALEZ FSS2018-0108 PGA West Mutiuse Bldg Orr Hold Harmless - County Riverside ....pdf FSS2018-0108 PGA West Mutiuse Bldg Orr Hold Harmless - County Riverside ....pdf 1 DOC 11/15/2018 EDGAR GONZALEZ FSS2018-0108 PGA West Underground piping test certificate .pdf FSS2018-0108 PGA West Underground piping test certificate .pdf 1 BOND INFORMATION SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is subject to field inspection. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Printed: Wednesday, January 18, 2023 4:40:14 PM 8 of 8 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0108