Loading...
FSS2018-0110ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)819-5476 JCFIREPROTECTION@V ERIZON.NET BILL TO J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)819-5476 JCFIREPROTECTION@V ERIZON.NET CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 (760)819-5476 JCFIREPROTECTION@V ERIZON.NET OWNER BRIAN STEMMER 52940 AVENIDA VELASCO LA QUINTA CA 92253 (760)819-5476 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PLAN CHECK PICKED UP AARON HICKSON 8/10/2018 8/10/2018 BRIAN STEMMER PICKED UP PLAN CHECK CONDITIONS Description: STEMMER / VELASCO FIRE SPRINKLER Type: FIRE SPRINKLER Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 7/2/2018 AHI Parcel No: 774054025 Site Address: 53095 AVENIDA VELASCO LA QUINTA,CA 92253 Approved: 7/20/2018 EGO Subdivision: SANTA CARMELITA VALE LA QUINTA UNIT 21 Block: 217 Lot: 5 Issued: 9/17/2018 AHI Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 1/9/2019 EGO Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Tuesday, January 31, 2023 12:02:40 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0110 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING EGO 10/30/2018 10/30/2018 APPROVED OVERHEAD HYRO EGO 10/30/2018 10/30/2018 APPROVED FIRE FINAL**EGO 1/9/2019 1/9/2019 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $156.00 $156.00 7/2/18 R37135 1447 CHECK J C FIRE PROTECTION AHI FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $234.00 $234.00 7/2/18 R37135 1447 CHECK J C FIRE PROTECTION AHI Total Paid for FIRE FEES: $390.00 $390.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 7/2/18 R37135 1447 CHECK J C FIRE PROTECTION AHI Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/2/18 R37135 1447 CHECK J C FIRE PROTECTION AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$405.00 $405.00 Printed: Tuesday, January 31, 2023 12:02:40 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0110 1ST PERMIT TECH (1 DAY) AARON HICKSON 7/2/2018 7/3/2018 7/3/2018 COMPLETE 1ST FIRE (2 WK)EDGAR GONZALEZ 7/2/2018 7/16/2018 7/20/2018 APPROVED- CONDITIONS The Riverside County Fire Department has reviewed the Residential Fire Sprinkler plans and they are approved with the following conditions in accordance with NPFA 13D 2016: General Requirements 1. Installation of sprinkler system shall only be performed by people knowledgeable and trained in such systems. Provide proof of training. NFPA 13D Sec. 4.6 2. Contractors Test and Material Certificate shall be submitted upon final inspection. (NFPA 13 Sec. 24.1) 3. An owner’s manual for the fire sprinkler system shall be provided to the owner. 4. A sign or valve tag shall be installed at the main shutoff valve(s) to the water distribution system stating: “Warning, the water system in this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure automatically shut off the water to the fire sprinkler system, such as water softeners filtration systems and automatic shutoff valves, shall not be added to the system without a review of the fire sprinkler system by a fire protection specialist. Do not remove this sign.” 5. Local water flow alarms shall be provided on all sprinkler systems in homes not equipped with smoke detectors. (NFPA 13D Sec. 7.6) Printed: Tuesday, January 31, 2023 12:02:40 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0110 ATTACHMENTS BOND INFORMATION Inspection Requirements 1. Rough and Hydro: All piping must be visible and hydrostatically tested for leakage at normal system operating pressure OR manufacturer’s prescribed pressure, PRIOR TO CONCEALMENT. 2. Final Inspection. The Fire Department job card, approved plans and conditions letter must be at the job site always. Approval of this plan is subject to field inspection. Should there be need for further information and/or clarification, please contact the undersigned. Thank you for your continuing cooperation in advance. Edgar Gonzalez Fire Safety Specialist Printed: Tuesday, January 31, 2023 12:02:40 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0110