Loading...
FSS2018-0134ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT John Paulus 72120 Northshore St. Ste. "C" Thousand Palms CA 92276 (760)404-1350 jpaulus@shastafire.co m BILL TO Shasta Fire Protection 72120 Northshore St (C) Thousand Palms CA 92276 (760)404-1350 jpaulus@shastafire.co m CONTRACTOR Shasta Fire Protection 72120 Northshore St (C) Thousand Palms CA 92276 (760)404-1350 jpaulus@shastafire.co m OWNER WESTATES HOLDINGS 988 VILLA MONTES CIR CORONA CA 92253 (760)404-1350 CONDITIONS Description: DESIGN & INSTALL AUTO FIRE SPKRS WITHIN EXISTING T.I. Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 8/24/2018 EPRS Parcel No: 600390004 Site Address: 79440 HIGHWAY 111 STE 104 LA QUINTA,CA 92253 Approved: 9/7/2018 EGO Subdivision: PM 31172 Block: Lot: 4 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 12/11/2018 EGO Valuation: $9,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Friday, February 10, 2023 11:26:23 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0134 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING EGO OVERHEAD HYRO EGO FIRE FINAL**EGO APPROVED REVIEWS PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY Credit Card Fee 101-0000-43505 0 $7.29 $7.29 8/24/18 WEB2851 CREDIT John Paulus EPRS Total Paid for Credit Card Fee: $7.29 $7.29 FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $156.00 $156.00 8/24/18 WEB2851 CREDIT John Paulus EPRS FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $234.00 $234.00 8/24/18 WEB2851 CREDIT John Paulus EPRS Total Paid for FIRE FEES: $390.00 $390.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 8/24/18 WEB2851 CREDIT John Paulus EPRS Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 8/24/18 WEB2851 CREDIT John Paulus EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$412.29 $412.29 Printed: Friday, February 10, 2023 11:26:23 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0134 REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 8/24/2018 8/27/2018 8/24/2018 COMPLETE 1ST FIRE (2 WK)EDGAR GONZALEZ 8/24/2018 9/7/2018 9/7/2018 APPROVED- CONDITIONS 9/7/2018 John Paulus Shasta Fire Protection 72120 Northshore St. - C Thousand Palms CA, Re: La Quinta OBGYN – Fire Sprinkler TI FSS2018-0134 79-440 Hwy 111 – 104 La Quinta CA, 92253 The Fire Sprinkler TI plans you submitted for the above referenced project have been reviewed by the Riverside County Fire Department and are approved with the following conditions: 1.) Provide spare sprinkler head of each type installed at fire sprinkler riser’s spare head box (at least 1.) 2.) Existing fire sprinkler system shall have a current 5 year inspection/certification. Proof shall be provided on or before final is granted. 3.) Fire Sprinkler system tenant improvements with 20 or more heads augmented/affected shall be hydrostatically tested at 200 psi or 50 above static pressure, whichever is greater. 4.) Approval of this plan is subject on the following field inspections: • Overhead Rough/Piping Inspection • Final Inspection The Fire Department approved plans and Printed: Friday, February 10, 2023 11:26:23 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0134 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/7/2018 EDGAR GONZALEZ FSS2018-0134 - LA QUINTA OBGYN - 79- 440 HWY 111 - 104 - FIRE SPRINKLER TI (COA).docx FSS2018-0134 - LA QUINTA OBGYN - 79- 440 HWY 111 - 104 - FIRE SPRINKLER TI (COA).docx 1 DOC 9/10/2018 EDGAR GONZALEZ LQ OBGYN Fire Sprinkler Plans - APPROVED..pdf LQ OBGYN Fire Sprinkler Plans - APPROVED..pdf 1 DOC 8/24/2018 EtrakitPublicReg FIRE SPRINKLER T.I. PLAN LQ OBGYN Fire Sprinkler Plans.pdf 1 DOC 8/24/2018 EtrakitPublicReg SPEC SHEETS FOR T.I.Spec Sheets.pdf 1 BOND INFORMATION conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777-7131. SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is subject to field inspection. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Edgar Gonzalez - Fire Safety Specialist Printed: Friday, February 10, 2023 11:26:23 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0134 COPIERCLG 9'-8"RECEPTIONCLG 9'-8"EXAM 1CLG 9'-8"EXAM 2CLG 9'-8"OPEN OFFICECLG 9'-8"HALLCLG 9'-8"HALLCLG 9'-8"LABCLG 9'-8"RESTROOMCLG 9'-8"RESTROOMCLG 9'-8"HALLCLG 9'-8"EXAM 4CLG 9'-8"EXAM 5CLG 9'-8"LOUNGECLG 9'-8"RESTROOMCLG 8'-0"SHOWERCLG 8'-0"EXAM 7CLG 9'-8"NURSE STATIONCLG 9'-8"EXAM 3CLG 9'-8"WAITINGCLG 9'-8"FETAL MONITORINGCLG 9'-8"EXAM 6CLG 9'-8"CLG 8'-2"CLG 8'-2"HANGER LEGENDSTANDARD SYMBOLS1 - U - HOOK2 - C CLAMP, ROD, & RING3 - POWDER STUD, ROD, & RING5 - EYE ROD, & RING4 - ANGLE CLIP, ROD, & RING6 - COACH SCREW, ROD, & RING7 - CONC. SHELL, ROD, & RING - CHECK VALVE - O. S. & Y. VALVE - FIRE DEPT. CONNECTION - FIRE HYDRANT - KEY VALVE - POST INDICATOR VALVE - UNDG. BY SHASTA FIRE - UNDG. BY OTHERSSTANDARD SYMBOLS - RISER WITH ALARM VALVE - RISER WITH FLOW SWITCH - WATER MOTOR GONG - ELECTRIC BELL - PIPE HANGER LOCATION - FOUR WAY SWAY BRACE - TWO WAY SWAY BRACE - HYDRAULIC NODE POINTNOZZLEMFG.DEGREEK-FACTORFINISHQUANTITYCONTRACT WITHARCHITECTWATER COMPANYFIELD INSPECTIONNO. DATE:REVISIONSSCALE:PROJECT:STATE LIC. NO.(CA.) 476633(AZ.) 101519LIC. CLASS C-16DRAWN BY:DATE:JOB NO.DRWG. NO.OFPHONE: (760) 323-5993FAX: (760) 323-8895info@shastafire.com18-0478-22-18KEVIN G.1/4"=1'-0"SHASTA FIRE PROTECTION, INC.72120 Northshore St. Suite CThousand Palms, Ca. 92276RIVERSIDE COUNTY FIRE DEPT.NPAGE CONTENTS:SYSTEMSYSTEM DESIGN DATAWETDATA REQUIREMENT SQ. FT./HEAD APPLICATIONALLOWANCEOF RISERSUPPLYP.S.I.P.S.I.FLOWINGSOURCE:DATE:TIME:DRYCALCULATEDPIPE SCHEDULEPRE-ACTIONDELUGETYPEHYD. DESIGNAREA OFHOSETOTAL SYSTEM@ BASEWATERSTATICRESIDUALG.P.M.PIPING PLAN1238CHROME155VK302 PENDENTVIKING5.6FIRE SPRINKLER GENERAL NOTES1.SPRINKLER PLANS SHALL BE APPROVED PRIOR TO INSTALLATION OF ANY PIPE. A SET OFAPPROVED PLANS SHALL BE MAINTAINED AT ALL TIMES AT THE CONSTRUCTION SITE.2.THIS AUTOMATIC FIRE PROTECTION SYSTEM SHALL BE DESIGNED, FABRICATED ANDINSTALLED IN ACCORDANCE WITH THE 2016 NFPA 13 WITH CALIFORNIA AMENDMENTS,2016 CFC , AND LOCAL CODES.3.SPRINKLER SYSTEM IS WET.4.ALL MATERIAL TO BE NEW AND U.L. LISTED FOR FIRE PROTECTION SERVICE. ONLY NEWU.L. LISTED FIRE SPRINKLERS SHALL BE INSTALLED IN THE FIRE SPRINKLER SYSTEM.5.ALL STEEL PIPE TO BE SCHEDULED APPROVED FOR FIRE PROTECTION SERVICE.6.ALL GROOVED FITTINGS AND/ OR SADDLES TO BE VICTUALIC FIRELOCK OR EQUAL. ALLGROOVED FITTINGS ARE TO BE RIDGED UNLESS NOTED OTHERWISE.7.ALL COUPON DISCS FROM MECHANICAL TEE'S WILL BE WIRED TO PIPE AND RETAINED FORINSPECTION.8.PENETRATIONS OF RATED CORRIDORS, WALLS, AND ASSEMBLIES SHALL BE SEALED INACCORDANCE 2016 CBC.9.UNSUPPORTED STEEL ARMOVERS LENGTH SHALL NOT EXCEED OVER 24 INCHES WHENSTATIC PRESSURE IS LESS THAN 100 PSI10.A STOCK OF SPARE FIRE SPRINKLERS OF EACH STYLE, TYPE, AND TEMPERATURE RATINGALONG WITH A SPRINKLER WRENCH SHALL BE LOCATED AT THE MAIN SYSTEM RISER OROTHER APPROVED LOCATION.11.ALL VALVES SHALL HAVE A PERMANENTLY AFFIXED SIGN INDICATING FUNCTION ANDBUILDING PROTECTED.12.THE INSTALLER SHALL PERFORM ALL REQUIRED ACCEPTANCE TESTS IN THE PRESENCEOF THE FIRE INSPECTOR.13.WHERE ADDITION OR MODIFICATION IS MADE TO AN EXISTING SYSTEM AFFECTING MORETHAN 20 SPRINKLERS, THE NEW PORTION SHALL BE ISOLATED AND TESTED AT NO LESSTHAN 200 PSI OR 50 POUNDS OVER THE STATIC PRESSURE OF THE SYSTEM IF HIGHERFOR 2 HOURS.14.SPRINKLER SYSTEM SHALL BE FLUSHED TO REMOVE FOREIGN MATERIAL THAT MAY HAVEENTERED THE OVERHEAD SYSTEM DURING INSTALLATION. THE WATER SHALL BEFLUSHED UNTIL THE WATER IS CLEAR AND ACCEPTED BY THE INSPECTO15.A COPY OF THE NFPA 25, 2016 CALIFORNIA EDITION SHALL BE GIVEN TO THE OWNER ANDTENANT.OVERHEAD / MATERIAL NOTESINTERNAL DIAMETERS FOR THREADABLE THIN-WALL ARE AS FOLLOWS:1" 1.080 ID1 1/4" 1.408 ID1 1/2"1.639 ID2" 2.104 IDINTERNAL DIAMETERS FOR BLACK STEEL SCH. 40 ARE AS FOLLOWS:1" 1.049 ID1 1/4" 1.380 ID1 1/2" 1.610 ID2" 2.067 ID·THREADABLE THIN-WALL OR BLACK STEEL SCH. 40 PIPING TO HAVE THREADED ENDSAND CAST IRON CLASS 125 SCREWED FITTINGS·ALL "RISER NIPPLES" FROM MAIN TO LINE PIPE, WILL BE SCH. 30 BLK. STEEL·ALL "DROPS" TO SPRINKLER HEADS, WILL BE SCH. 30 BLK. STEEL·SPACING OF AUTOMATIC FIRE SPRINKLER HEADS WILL BE IN ACCORDANCE WITH NFPA13D (2016 EDITION)·SPRINKLER HEADS AT FINISHED CEILING WILL BE SPACED PER CODE·ALL AUTOMATIC FIRE SPRINKLER SYSTEM PIPING (OVERHEAD) TO BE INSPECTED, ANDHYDROSTATICALLY TESTED FOR TWO (2) HOURS, AND WITNESSED BY FIRE DEPT.,PRIOR TO FINISHED CEILING BEING INSTALLED·SHASTA FIRE PROTECTION INC., TAKES NO RESPONSIBILITY FOR STRUCTURAL FAILUREDUE TO WATER FILLED SPRINKLER PIPING LOADS·SYSTEM DESIGN WILL BE IN ACCORDANCE WITH NFPA 13D (2016 EDITION)·THREADABLE THINWALL OR BLACK STEEL SCH. 40·PIPING TO HAVE THREADED ENDS AND CAST IRON CLASS 125 SCREWED FITTINGSTENANT IMPROVEMENT NOTES1.THIS BUILDING HAS BEEN FULLY FIRE SPRINKLERED (SHELL & CORE) TO MEET THEREQUIREMENTS OF THE LOCAL FIRE AUTHORITY.2.THE EXISTING AUTOMATIC SPRINKLER SYSTEM HAS BEEN DESIGNED TO SUPPLY FUTURETENANT IMPROVEMENT FINISHED CEILING SPRINKLER HEADS.3.ALL PIPE AND MATERIAL USED FOR NEW T.I. WILL BE U.L. LISTED AND RATED FOR 175 lbs.P.S.I. ALL HANGERS AND BRACING REQUIRED WILL BE ATTACHED AND SPACED per N.F.P.A.13 (2016). ANY WORK (ADDED HEADS ABOVE OR BELOW CEILING) BEYOND WALLS OF THISDESIGN IS NOT IN THIS CONTRACT.SCOPE OF WORKSHASTA FIRE PROTECTION, INC.'S SCOPE OF WORK FOR THIS SYSTEM IS TO DESIGN ANDINSTALL AUTOMATIC FIRE SPRINKLERS AT THE FINISHED CEILING LEVEL PER N.F.P.A 13(2016) AND ANY FIRE DEPARTMENT REQUIREMENTS. NEW FIRE SPRINKLER HEAD SUPPLYWILL BE TAKEN FROM THE EXISTING AUTOMATIC SPRINKLER SYSTEM SUPPLY OUTLETSAND / OR NEW MECHANICAL TAP FOR SUPPLY AT THE EXISTING PIPE. IN EITHER CASE THEPIPE SIZING TO THE NEW HEADS WILL BE THE SAME AS THE EXISTING SYSTEM. EXISTINGUPRIGHT ATTIC PROTECTION WILL REMAIN "AS-IS".APPROVAL BLOCKVIKING VK-302 PENDENTINFORMATIONK=5.6, 155o, SIN#VK302MAXIMUM AREA OF COVERAGE:15' X 15' (7'-6" TO ANY WALL)MINIMUM WATER SUPPLY REQUIREMENT:14.8 G.P.M. @ 7.0 P.S.I.1" TO 12" BELOW FINISHED CEILINGCOACHELLA VALLEY WATER760-863-8886760-398-2651EXISTING UPRIGHT ON ROOSTER-TAILEXISTING PIPENEW PIPELOWER EDGE OF ROOF DECKCEILING SPRINKLER1" PLUG FOR FUTUREOUTLET FOR FUTURE CEIL. SPRINKLER `ROOSTER TAIL' W/ 1"TYPICAL @ THIS HEAD SYMBOL1 X 1/2 X 1 C.I. TEEUPRIGHT IN 2'-0" CENTERLINEBRANCHLINESIDE SAMMYSAMMY SCREWRING HANGERFIG 200JOIST2X4TYPICAL ARMOVER310-10310-0311-11311-0310-8310-1034-9318-10 1¼ 4-10 1½ 9-8 1¼ 11-0 1¼ 11-0 14-0½14-0½18-016-916-2½13-6 14-1114-10 1 8 - 1½16-7½16-31 5- 1 0 ½ 1 5-0 ½15-815-3½12-512-4½12-714-1012-0½10-11½11-6½14-111-1013-9½11-013-11 1- 8 ½12-912-9½11-3½1 3- 2 ½15-1110-913-4½15-0½13-9½12-8½HAZARD CLASSIFICATION: LIGHT HAZARDVARISCO DESIGNS949-679-6300VARISCO DESIGNS949-679-6300LA QUINTA OB/GYN TI79440 HWY 111, SUITES 104-105LA QUINTA, CA COPIERCLG 9'-8"RECEPTIONCLG 9'-8"EXAM 1CLG 9'-8"EXAM 2CLG 9'-8"OPEN OFFICECLG 9'-8"HALLCLG 9'-8"HALLCLG 9'-8"LABCLG 9'-8"RESTROOMCLG 9'-8"RESTROOMCLG 9'-8"HALLCLG 9'-8"EXAM 4CLG 9'-8"EXAM 5CLG 9'-8"LOUNGECLG 9'-8"RESTROOMCLG 8'-0"SHOWERCLG 8'-0"EXAM 7CLG 9'-8"NURSE STATIONCLG 9'-8"EXAM 3CLG 9'-8"WAITINGCLG 9'-8"FETAL MONITORINGCLG 9'-8"EXAM 6CLG 9'-8"CLG 8'-2"CLG 8'-2"HANGER LEGENDSTANDARD SYMBOLS1 - U - HOOK2 - C CLAMP, ROD, & RING3 - POWDER STUD, ROD, & RING5 - EYE ROD, & RING4 - ANGLE CLIP, ROD, & RING6 - COACH SCREW, ROD, & RING7 - CONC. SHELL, ROD, & RING - CHECK VALVE - O. S. & Y. VALVE - FIRE DEPT. CONNECTION - FIRE HYDRANT - KEY VALVE - POST INDICATOR VALVE - UNDG. BY SHASTA FIRE - UNDG. BY OTHERSSTANDARD SYMBOLS - RISER WITH ALARM VALVE - RISER WITH FLOW SWITCH - WATER MOTOR GONG - ELECTRIC BELL - PIPE HANGER LOCATION - FOUR WAY SWAY BRACE - TWO WAY SWAY BRACE - HYDRAULIC NODE POINTNOZZLEMFG.DEGREEK-FACTORFINISHQUANTITYCONTRACT WITHARCHITECTWATER COMPANYFIELD INSPECTIONNO. DATE:REVISIONSSCALE:PROJECT:STATE LIC. NO.(CA.) 476633(AZ.) 101519LIC. CLASS C-16DRAWN BY:DATE:JOB NO.DRWG. NO.OFPHONE: (760) 323-5993FAX: (760) 323-8895info@shastafire.comLA QUINTA OB/GYN TI79440 HWY 111, SUITES 104-105LA QUINTA, CA18-0478-22-18KEVIN G.1/4"=1'-0"SHASTA FIRE PROTECTION, INC.72120 Northshore St. Suite CThousand Palms, Ca. 92276RIVERSIDE COUNTY FIRE DEPT.PAGE CONTENTS:SYSTEMSYSTEM DESIGN DATAWETHAZARD CLASSIFICATION: LIGHT HAZARDDATA REQUIREMENT SQ. FT./HEAD APPLICATIONALLOWANCEOF RISERSUPPLYP.S.I.P.S.I.FLOWINGSOURCE:DATE:TIME:DRYCALCULATEDPIPE SCHEDULEPRE-ACTIONDELUGETYPEHYD. DESIGNAREA OFHOSETOTAL SYSTEM@ BASEWATERSTATICRESIDUALG.P.M.REFLECTED CEILING PLAN2VARISCO DESIGNS949-679-6300238CHROME155VK302 PENDENTVIKING5.6FIRE SPRINKLER GENERAL NOTES1.SPRINKLER PLANS SHALL BE APPROVED PRIOR TO INSTALLATION OF ANY PIPE. A SET OFAPPROVED PLANS SHALL BE MAINTAINED AT ALL TIMES AT THE CONSTRUCTION SITE.2.THIS AUTOMATIC FIRE PROTECTION SYSTEM SHALL BE DESIGNED, FABRICATED ANDINSTALLED IN ACCORDANCE WITH THE 2016 NFPA 13 WITH CALIFORNIA AMENDMENTS,2016 CFC , AND LOCAL CODES.3.SPRINKLER SYSTEM IS WET.4.ALL MATERIAL TO BE NEW AND U.L. LISTED FOR FIRE PROTECTION SERVICE. ONLY NEWU.L. LISTED FIRE SPRINKLERS SHALL BE INSTALLED IN THE FIRE SPRINKLER SYSTEM.5.ALL STEEL PIPE TO BE SCHEDULED APPROVED FOR FIRE PROTECTION SERVICE.6.ALL GROOVED FITTINGS AND/ OR SADDLES TO BE VICTUALIC FIRELOCK OR EQUAL. ALLGROOVED FITTINGS ARE TO BE RIDGED UNLESS NOTED OTHERWISE.7.ALL COUPON DISCS FROM MECHANICAL TEE'S WILL BE WIRED TO PIPE AND RETAINED FORINSPECTION.8.PENETRATIONS OF RATED CORRIDORS, WALLS, AND ASSEMBLIES SHALL BE SEALED INACCORDANCE 2016 CBC.9.UNSUPPORTED STEEL ARMOVERS LENGTH SHALL NOT EXCEED OVER 24 INCHES WHENSTATIC PRESSURE IS LESS THAN 100 PSI10.A STOCK OF SPARE FIRE SPRINKLERS OF EACH STYLE, TYPE, AND TEMPERATURE RATINGALONG WITH A SPRINKLER WRENCH SHALL BE LOCATED AT THE MAIN SYSTEM RISER OROTHER APPROVED LOCATION.11.ALL VALVES SHALL HAVE A PERMANENTLY AFFIXED SIGN INDICATING FUNCTION ANDBUILDING PROTECTED.12.THE INSTALLER SHALL PERFORM ALL REQUIRED ACCEPTANCE TESTS IN THE PRESENCEOF THE FIRE INSPECTOR.13.WHERE ADDITION OR MODIFICATION IS MADE TO AN EXISTING SYSTEM AFFECTING MORETHAN 20 SPRINKLERS, THE NEW PORTION SHALL BE ISOLATED AND TESTED AT NO LESSTHAN 200 PSI OR 50 POUNDS OVER THE STATIC PRESSURE OF THE SYSTEM IF HIGHERFOR 2 HOURS.14.SPRINKLER SYSTEM SHALL BE FLUSHED TO REMOVE FOREIGN MATERIAL THAT MAY HAVEENTERED THE OVERHEAD SYSTEM DURING INSTALLATION. THE WATER SHALL BEFLUSHED UNTIL THE WATER IS CLEAR AND ACCEPTED BY THE INSPECTO15.A COPY OF THE NFPA 25, 2016 CALIFORNIA EDITION SHALL BE GIVEN TO THE OWNER ANDTENANT.OVERHEAD / MATERIAL NOTESINTERNAL DIAMETERS FOR THREADABLE THIN-WALL ARE AS FOLLOWS:1" 1.080 ID1 1/4" 1.408 ID1 1/2"1.639 ID2" 2.104 IDINTERNAL DIAMETERS FOR BLACK STEEL SCH. 40 ARE AS FOLLOWS:1" 1.049 ID1 1/4" 1.380 ID1 1/2" 1.610 ID2" 2.067 ID·THREADABLE THIN-WALL OR BLACK STEEL SCH. 40 PIPING TO HAVE THREADED ENDSAND CAST IRON CLASS 125 SCREWED FITTINGS·ALL "RISER NIPPLES" FROM MAIN TO LINE PIPE, WILL BE SCH. 30 BLK. STEEL·ALL "DROPS" TO SPRINKLER HEADS, WILL BE SCH. 30 BLK. STEEL·SPACING OF AUTOMATIC FIRE SPRINKLER HEADS WILL BE IN ACCORDANCE WITH NFPA13D (2016 EDITION)·SPRINKLER HEADS AT FINISHED CEILING WILL BE SPACED PER CODE·ALL AUTOMATIC FIRE SPRINKLER SYSTEM PIPING (OVERHEAD) TO BE INSPECTED, ANDHYDROSTATICALLY TESTED FOR TWO (2) HOURS, AND WITNESSED BY FIRE DEPT.,PRIOR TO FINISHED CEILING BEING INSTALLED·SHASTA FIRE PROTECTION INC., TAKES NO RESPONSIBILITY FOR STRUCTURAL FAILUREDUE TO WATER FILLED SPRINKLER PIPING LOADS·SYSTEM DESIGN WILL BE IN ACCORDANCE WITH NFPA 13D (2016 EDITION)·THREADABLE THINWALL OR BLACK STEEL SCH. 40·PIPING TO HAVE THREADED ENDS AND CAST IRON CLASS 125 SCREWED FITTINGSTENANT IMPROVEMENT NOTES1.THIS BUILDING HAS BEEN FULLY FIRE SPRINKLERED (SHELL & CORE) TO MEET THEREQUIREMENTS OF THE LOCAL FIRE AUTHORITY.2.THE EXISTING AUTOMATIC SPRINKLER SYSTEM HAS BEEN DESIGNED TO SUPPLY FUTURETENANT IMPROVEMENT FINISHED CEILING SPRINKLER HEADS.3.ALL PIPE AND MATERIAL USED FOR NEW T.I. WILL BE U.L. LISTED AND RATED FOR 175 lbs.P.S.I. ALL HANGERS AND BRACING REQUIRED WILL BE ATTACHED AND SPACED per N.F.P.A.13 (2016). ANY WORK (ADDED HEADS ABOVE OR BELOW CEILING) BEYOND WALLS OF THISDESIGN IS NOT IN THIS CONTRACT.SCOPE OF WORKSHASTA FIRE PROTECTION, INC.'S SCOPE OF WORK FOR THIS SYSTEM IS TO DESIGN ANDINSTALL AUTOMATIC FIRE SPRINKLERS AT THE FINISHED CEILING LEVEL PER N.F.P.A 13(2016) AND ANY FIRE DEPARTMENT REQUIREMENTS. NEW FIRE SPRINKLER HEAD SUPPLYWILL BE TAKEN FROM THE EXISTING AUTOMATIC SPRINKLER SYSTEM SUPPLY OUTLETSAND / OR NEW MECHANICAL TAP FOR SUPPLY AT THE EXISTING PIPE. IN EITHER CASE THEPIPE SIZING TO THE NEW HEADS WILL BE THE SAME AS THE EXISTING SYSTEM. EXISTINGUPRIGHT ATTIC PROTECTION WILL REMAIN "AS-IS".APPROVAL BLOCKVIKING VK-302 PENDENTINFORMATIONK=5.6, 155o, SIN#VK302MAXIMUM AREA OF COVERAGE:15' X 15' (7'-6" TO ANY WALL)MINIMUM WATER SUPPLY REQUIREMENT:14.8 G.P.M. @ 7.0 P.S.I.1" TO 12" BELOW FINISHED CEILINGCOACHELLA VALLEY WATER760-863-8886760-398-2651EXISTING UPRIGHT ON ROOSTER-TAILEXISTING PIPENEW PIPELOWER EDGE OF ROOF DECKCEILING SPRINKLER1" PLUG FOR FUTUREOUTLET FOR FUTURE CEIL. SPRINKLER `ROOSTER TAIL' W/ 1"TYPICAL @ THIS HEAD SYMBOL1 X 1/2 X 1 C.I. TEEUPRIGHT IN 2'-0" CENTERLINEBRANCHLINESIDE SAMMYSAMMY SCREWRING HANGERFIG 200JOIST2X4TYPICAL ARMOVERNVARISCO DESIGNS949-679-6300 microfast® quick response pendent sprinkler Vk302 (k5.6) tecHnical data Form No. F_033314 17.10.05 Rev 17.2 Page 1 of 6 the Viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. description The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: fm Global approves ent finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) 2. listinGs and approVals culus listed: Category VNIV fm approved: Class Series 2000 Vds approved: Certificates G414009 and G414010 lpcB approved ce certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-S0021 cccf approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. tecHnical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2” NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4” (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). material standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. ordering information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB available finishes and temperature ratings: Refer to Table 1. accessories: (Also refer to the current Viking price list.) Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) microfast® quick response pendent sprinkler Vk302 (k5.6) tecHnical data Form No. F_033314 17.10.05 Rev 17.2 Page 2 of 6 the Viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017). B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A ½” ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1” diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. sprinkler cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. installation Refer to appropriate NFPA Installation Standards. 5. operation During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. aVailaBility The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. figure 1: standard sprinkler Wrench 21475m/B protective sprinkler cap Wrench flat microfast® quick response pendent sprinkler Vk302 (k5.6) tecHnical data Form No. F_033314 17.10.05 Rev 17.2 Page 3 of 6 the Viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com taBle 1: aVailaBle sprinkler temperature ratinGs and finisHes sprinkler temperature classification sprinkler nominal temperature rating1 maximum ambient ceiling temperature2 Bulb color Ordinary 135 °F (57 °C)100 °F (38 °C)Orange Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue sprinkler finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT corrosion-resistant coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. figure 2: Wrench 13655W/B for recessed pendent sprinklers carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats sprinkler wrench 13655W/B** for recessed pendent sprinklers ** a 1/2” ratchet is required (not available from Viking) microfast® quick response pendent sprinkler Vk302 (k5.6) tecHnical data Form No. F_033314 17.10.05 Rev 17.2 Page 4 of 6 the Viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com approval chart 1 (ul) the Viking microfast® quick response pendent sprinkler Vk302 maximum 175 psi (12 Bar) WWp Base part number1 sin sprinkler style thread size nominal k-factor overall length listings and approvals3 (refer also to design criteria.) npt Bsp u.s.metric2 inches mm culus4 Vds lpcB 7 12979 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X A1 A1Z, B1Y D1Z, C1Y ---- 19780 VK302 Pendent 1/2” --5.6 80.6 2-1/4 58 ----------D3 21354 VK302 Pendent --15 mm 5.6 80.6 2-1/4 58 ----------D3 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06662B VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X ---------- 18021 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1X, B1Y A1 A1X, B1Y D1X, C1Y8 D1X, C1Y9 -- approved temperature ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) approved finishes 1 - Brass, Chrome, White Polyester5,6, Black Polyes- ter5,6 2 - ENT5 3 - Chrome approved escutcheons X - Standard surface-mounted escutcheon or the Viking Micromatic® Model E-1 Recessed Escutcheon Y - Standard surface-mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro- matic® Model E-1, E-2, or E-3 Recessed Escutcheon Z - Standard surface-mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. 9 MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. desiGn criteria - ul (Also refer to Approval Chart 1 above.) culus listing requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. important: always refer to Bulletin form no. f_091699 - care and Handling of sprinklers. also refer to form no. f_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of nfpa, lpcB, apsad, Vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. microfast® quick response pendent sprinkler Vk302 (k5.6) tecHnical data Form No. F_033314 17.10.05 Rev 17.2 Page 5 of 6 the Viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com approval chart 2 (fm) the Viking microfast® quick response pendent sprinkler Vk302 maximum 175 psi (12 Bar) WWp Base part number1 sin sprinkler style thread size nominal k-factor overall length fm approvals3 (refer also to design criteria.)npt Bsp u.s.metric2 inches mm 12979 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06662B VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y approved temperature ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) approved finishes 1 - Brass, Chrome, White Polyester4, and Black Polyester4 2 - ENT5 approved escutcheons X - Standard surface-mounted escutcheon or the Viking Micromatic® Model E-1 Recessed Escutcheon Y - Standard surface-mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon, or recessed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon Z - Standard surface-mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion resistant. desiGn criteria - fm (Also refer to Approval Chart 2 above.) fm approval requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. note: the fm installation guidelines may differ from culus and/or nfpa criteria. important: always refer to Bulletin form no. f_091699 - care and Handling of sprinklers. also refer to page f_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of nfpa, fm Global, lpcB, apsad, Vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. microfast® quick response pendent sprinkler Vk302 (k5.6) tecHnical data Form No. F_033314 17.10.05 Rev 17.2 Page 6 of 6 the Viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com figure 4: sprinkler dimensions with the model e-1 and e-2 recessed escutcheons figure 3: sprinkler dimensions with a standard escutcheon and the model f-1 adjustable escutcheon 1/2” (15 mm) npt 2-1/4” (57 mm)1-3/4” (45 mm) 2” (51 mm)max. 2-1/8” (54 mm) 1-1/2” (38 mm)min. installed with a standard 1/8” surface-mounted escutcheon installed with a microfast model f-1 adjustable escutcheon ceiling opening size: 2-5/16” (59 mm) minimum 2-1/2” (64 mm) maximum note: at maximum, adapter is exposed 1/2” (13 mm) from face of ceiling 1-3/4” (45 mm)max. 2-1/8” (54 mm) 1-1/8” (29 mm)min. 2”” (51 mm)max. 1-1/8” (29 mm)min. 2-1/8” (54 mm) ceiling opening size: 2-5/16” (59 mm) minimum 2-1/2” (64 mm) maximum installed with a model e-1 recessed escutcheon installed with a model e-2 thread-on recessed escutcheon Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) 5 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETENot less than 2” nominal width (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bot- tom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Floor Joist Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) Box Qty Case Qty HORIZONTAL MOUNT 1/4"8019957 SWG 200 1/4 x 2"1725 (Fir)25 125 3/8"8020957 SWG 10 1/4 x 1"622 (Fir)300 25 125 3/8"8021957 SWG 20 1/4 x 2"1725 (Fir)1050 25 125 3/8"8073925 SWG 20-SS 1/4 x 2"1725 (Fir)850 25 125 3/8"*8022925 SWG 25-380 3/8 x 2-1/2"2249 (Fir)1500 25 125 3/8"8023925 SWG 30 1/4 x 3"1884 (Fir)25 125#14 SW Red Nut Driver Part # 8114910 • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Made in the U.S.A. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Box Qty Case Qty SWIVEL MOUNT 3/8"8139957 SH-GST 20 1/4 x 2"1257 (Fir)1050 1475 25 125 3/8"8141957 SH-GST 30 1/4 x 3"1720 (Fir)1500 1475 25 125 3/8"*8269957 SH-GST/CST 20 5/16 x 1-3/4” 1903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 1500 850 @ 45°25 125 1/2”8303957 SH-GST/CST 2.0 5/16 x 1-3/4” 903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 25 125 #14 Black Nut DriverPart # 8113910 • Eliminates distortion of threaded rod. • Accommodates up to 3 ½” x 12 pitch roof. • Allows 17° deflection from vertical. • Saves time from traditional methods. • Reduces installation costs. • Made in the U.S.A. Application Product Features Application Product Features Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380. Tool available on page 11. Watch a video demonstration atwww.itwbuildex.com SIDEWINDER® FOR WOOD - Horizontal Application SAMMYS SWIVEL HEAD™ FOR WOOD - Swivel Application #14 SH Orange Nut DriverPart # 8273910 * May require pre-drilling; consult joist manufacturer. * May require pre-drilling; consult joist manufacturer. Pipe HangersPipe Hangers 60 Eaton All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports TOLCO™Fig. 200 - “Trimline” Adjustable Band Hanger TOLCO™Fig. 200F - “Trimline” Adjustable Band Hanger with Felt Lining for Copper Tubing TOLCO™Fig. 200C - “Trimline” Adjustable Band Hanger with Plastic Coated TOLCO™Fig. 200S - “Trimline” Adjustable Band Hanger with Removable Nut (For sizes 1” thru 2”) Size Range: Fig. 200 - 1/2” (15mm)thru 8” (200mm)pipe Material:Steel, Pre-Galvanized to G90 specifications Function:For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: •1/2” (15mm)thru 2” (50mm)sizes have flared edges for ease of installation on all pipe types and protects CPVC plastic pipe from abrasion. Captured knurled nut design (flared top) on 1” thru 2” sizes keep nut from separating with hanger. Hanger is easily installed around pipe. •1/2” (15mm), 3/4” (20mm), and 21/2” (65mm)thru 8” (200mm)) Spring tension on nut holds it securely in hanger before installation. Knurled nut is easily removed. • For 1/2” (15mm)and 3/4” (20mm)sizes with non-captured knurl nuts order Fig. 200S Approvals:Underwriters Laboratories listed (1/2” (15mm)thru 8” (200mm)) in the USA (UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4” (20mm)thru 8” (200mm)). Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature:650°F (343°C) Finish:Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By:Part number and pipe size ** Note:For metric hanger rod sizes add the metric rod size to the figure number. Example: 200M8-11/2 or 200M10-1 1/2 A B D Fig. 200-1 to 200-2 Fig. 200-1/2 & 200-3/4 Fig. 200-21/2 to 200-8 Pipe Size Rod Size ABDMax. Rec. Load Approx. Wt./100 Part No.** in. (mm) in. mm** in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 200-1/2 1/2"(15)3/8"-16 M8 or M10 3 1/8"(79.4)25/8"(66.7)111/32"(34.1) 400 (1.78)11 (5.0) 200-3/4 3/4"(20)3/8"-16 M8 or M10 3 1/8"(79.4)21/2"(63.5)11/16"(27.0) 400 (1.78)11 (5.0) 200-1 1"(25)3/8"-16 M8 or M10 3 3/8"(85.7)25/8"(66.7)11/8"(28.6)400 (1.78)12 (5.5) 200-11/4 11/4"(32)3/8"-16 M8 or M10 3 3/4"(94.0)27/8"(73.0)15/32"(29.3) 400 (1.78)13 (5.9) 200-11/2 11/2"(40)3/8"-16 M8 or M10 3 7/8"(98.4)27/8"(73.0)13/16"(30.2) 400 (1.78)14 (6.4) 200-2 2"(50)3/8"-16 M8 or M10 4 1/2"(114.3)3"(76.3)13/16"(30.2) 400 (1.78)15 (6.9) 200-21/2 21/2"(65)3/8"-16 M10 5 5/8"(142.9)41/8"(104.7)17/16"(36.5) 600 (2.67)27 (12.3) 200-3 3"(75)3/8"-16 M10 5 7/8"(149.1)4"(101.6)11/4"(31.7) 600 (2.67)29 (13.3) 200-31/2 31/2"(90)3/8"-16 M10 7 3/8"(187.3)51/4"(133.3)23/16"(55.6) 600 (2.67)34 (15.6) 200-4 4"(100)3/8"-16 M10 7 3/8"(187.3)5"(127.0)13/8"(34.9) 1000 (4.45)35 (16.0) 200-5 5"(125)1/2"-13 M12 9 1/8"(231.8)61/4"(158.7)311/32"(84.9) 1250 (5.56)66 (30.2) 200-6 6"(150)1/2"-13 M12 10 1/8"(257.2)63/4"(171.4)27/32"(56.3) 1250 (5.56)73 (33.4) 200-8 8"(200)1/2"-13 M12 13 1/8"(333.4)83/4"(222.2)37/32"(81.7) 1250 (5.56)136 (62.3) Fig. 200C 200C-11/2 shown Fig. 200F 200F-11/2 shown Fig. 200 & Fig. 200S shown with non-captured nut Fig. 200 shown with captured nut 1” thru 2” sizes only A Overall Height B Center of pipe to top of knurled hanger rod nut. D Top of pipe to bottom of hanger rod nut. As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. SCHEDULE 10 & 40 ADVANTAGES: • UL listed (US & Canada) and FM approved • ASTM A135 and A795 Type E, Grade A Certified • Complies with NFPA-13, 13R and 14 • Industry-leading hydraulic characteristics • CRR of 1.0 and greater • All pipe NDT weld tested OTHER BENEFITS/SERVICES: • We have the most stocking locations in the industry, for best delivery and availability • Plain end or roll groove • Eddy Guard II™ bacterial-resistant internal coating • Custom length options • Hot dipped galvanization • Reddi-Pipe® red or black pipe eliminates field painting • Compatible for use in wet, dry, preaction and deluge sprinkler systems • The only maker with EPDs (to help earn LEED points). Always ready to protect your most valuable assets. SCHEDULE 10 & 40 Exclusive maker of Reddi-Pipe® RED OR BLACK PAINTED PIPE. 800.325.4467 sales@BullMooseIndustries.com BullMooseTube.com Nominal Pipe Size (Inches)1"1-1/4" 1-1/2"2"2-1/2"3"4"6"8" O.D. (in)1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 I.D. (in)1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 Empty Weight (lb/ft)1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 Water Filled Weight (lb/ft)1.820 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.086 C.R.R.15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 Pieces per Lift 91 61 61 37 30 19 19 10 7 Lift Weight (lbs) 21' lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 1,951 2,490 Lift Weight (lbs) 24' lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 Lift Weight (lbs) 25' lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670SCHEDULE 10NPS (In.)1"1-1/4" 1-1/2"2"2-1/2"3"4" 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.049 1.380 1.610 2.067 2.469 3.068 4.026 1.680 2.270 2.720 3.660 5.800 7.580 10.800 2.055 2.918 3.602 5.114 7.875 10.783 16.316 1.00 1.00 1.00 1.00 1.00 1.00 1.00 70 51 44 30 30 19 19 2,470 2,431 2,513 2,306 3,654 3,024 4,309 2,822 2,778 2,872 2,635 4,176 3,456 4,925 2,940 2,894 2,992 2,745 4,350 3,601 5,130SCHEDULE 40Bull Moose Fire Sprinkler Pipe Product Information PF-6.13 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: MALLEABLE IRON FITTINGS Class 150 (Standard) Note: See following page for pressure-temperature ratings. Galvanized weights may vary. Please contact your Anvil Representative if you need verification. All Elbows & Tees 3/8" (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) FIGURE 1101 90˚ Elbow Size A Unit Weight Black Galv. NPS DN in mm lbs kg lbs kg 1/8 6 11/16 17 0.06 0.03 0.06 0.03 1/4 8 13/16 22 0.11 0.05 0.11 0.05 3/8 10 15/16 24 0.17 0.08 0.17 0.08 1/2 15 11/8 29 0.30 0.14 0.30 0.14 3/4 20 15/16 33 0.45 0.20 0.45 0.20 1 25 11/2 38 0.73 0.33 0.73 0.33 11/4 32 13/4 44 0.97 0.44 0.97 0.44 11/2 40 115/16 49 1.30 0.59 1.30 0.59 2 50 21/4 57 2.06 0.93 2.06 0.93 21/2 65 211/16 68 3.55 1.61 3.55 1.61 3 80 31/16 78 5.46 2.48 5.46 2.48 31/2 90 37/16 87 7.10 3.22 7.10 3.22 4 100 313/16 98 8.95 4.06 8.95 4.06 5 125 41/2 114 13.90 6.30 13.90 6.30 6 150 51/8 130 23.00 10.43 23.00 10.43 A A q MALLEABLE IRON FITTINGS PF-11.16 Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME B16.39. ALL ELBOWS & TEES 3⁄8" (10 DN) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 Sizes 1⁄4"–1" (6–25 mm) Sizes 11⁄4"–2" (32–51 mm) Sizes 21⁄2"–3" (64–76 mm) (°F)(°C)psi bar psi bar psi bar psi bar -20° to 150° -28.9° to 65.6° 300 20.7 2,000 137.9 1,500 103.4 1,000 68.9 200°93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 250°121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 300°148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 350°176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 400°204.4 ––935 64.5 750 51.7 560 38.6 450°232.2 ––725 50.0 600 41.4 475 32.8 500°260.0 ––510 35.2 450 31.0 385 26.5 550°287.8 ––300 20.7 300 20.7 300 20.7 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil Sales Representative. Standards and Specifications Dimensions Material Galvanizing *Thread Pressure Rating MALLEABLE IRON FITTINGS Class 150/PN 20 ASME B16.3 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.3 Class 300/PN 50 ASME B16.3 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.3 MALLEABLE IRON UNIONS Class 150/PN 20 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 Class 250 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 Class 300/PN 50 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 * ASTM B 633. Type I, SC 4, may be supplied as alternate zinc coating per applicable ASME B16 product standard. Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature Pressure Class 150 Class 250 Class 300 (°F) (°C)psi bar psi bar psi bar -20° to 150° -28.9° to 65.6° 300 20.7 500 34.5 600 41.4 200°93.3°265 18.3 455 31.4 550 37.9 250°121.1°225 15.5 405 27.9 505 34.8 300°148.9°185 12.8 360 24.8 460 31.7 350°176.7°150 10.3 315 21.7 415 28.6 400°204.4°110 7.6 270 18.6 370 25.5 450°232.2°75 5.2 225 15.5 325 22.4 500°260.0°––180 12.4 280 19.3 550°287.8°––130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F MALLEABLE IRON FITTINGS 1) Inspect both male and female components prior to assembly. • Threads should be free from mechanical damage, dirt, chips and excess cutting oil. • Clean or replace components as necessary. 2) Application of thread sealant • Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant may be utilized. • Thoroughly mix the thread sealant prior to application. • Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3) Joint Makeup • For sizes up to and including 2" pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for 1⁄2" through 2" thread varies from 41⁄2 turns to 5 turns. • For 2 1⁄2" through 4" sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 2 1⁄2" through 4" thread varies from 51⁄2 turns to 63⁄4 turns. General Assembly of Threaded Fittings PF-11.13 Office of the Fire Marshal City of La Quinta 78-495 Calle Tampico, La Quinta CA 92253 • Phone (760)777-7000 •Direct (760)777-7074 9/7/2018 John Paulus Shasta Fire Protection 72120 Northshore St. - C Thousand Palms CA, Re: La Quinta OBGYN – Fire Sprinkler TI FSS2018-0134 79-440 Hwy 111 – 104 La Quinta CA, 92253 The Fire Sprinkler TI plans you submitted for the above referenced project have been reviewed by the Riverside County Fire Department and are approved with the following conditions: 1.) Provide spare sprinkler head of each type installed at fire sprinkler riser’s spare head box (at least 1.) 2.) Existing fire sprinkler system shall have a current 5 year inspection/certification. Proof shall be provided on or before final is granted. 3.) Fire Sprinkler system tenant improvements with 20 or more heads augmented/affected shall be hydrostatically tested at 200 psi or 50 above static pressure, whichever is greater. 4.) Approval of this plan is subject on the following field inspections: • Overhead Rough/Piping Inspection • Final Inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777- 7131. SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is subject to field inspection. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Edgar Gonzalez - Fire Safety Specialist