Loading...
FSS2018-0182ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET BILL TO J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET OWNER PATRICIA HUNTER 52743 VIA SAVONA LA QUINTA CA 0 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PLAN CHECK PICKED UP STEPHANIE SWANSTROM 12/13/2018 12/13/2018 PLAN CHECK PICKED UP BY JC FIRE RESUBMITTAL AARON HICKSON 12/17/2018 12/17/2018 CONDITIONS Description: HUNTER RESIDENCE - FIRE SPRINKLER SYSTEM Type: FIRE SPRINKLER Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 11/28/2018 AHI Parcel No: 777210018 Site Address: 80160 VIA PESSARO LA QUINTA,CA 92253 Approved: 12/18/2018 EGO Subdivision: TR 29894-2 Block: Lot: 204 Issued: 12/20/2018 JLIM Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 6/26/2019 EGO Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Thursday, January 12, 2023 2:48:51 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0182 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING EGO 1/15/2019 1/17/2019 APPROVED W/EXCEPTIO N 2 HEADS REQUIRE RE-ADJUSTMENT IN BEDROOM. SEE APPROVED PLAN FOR FURTHER DETAILS. OVERHEAD HYRO EGO 1/16/2019 1/16/2019 APPROVED FIRE FINAL**EGO 6/4/2019 6/5/2019 NOT READY NEEDS TO SEND PICTURE OF MISSING ESCUTCHEON TRIMS ON EXTERIOR WALKWAY. FIRE FINAL**EGO 6/24/2019 6/26/2019 APPROVED PARENT PROJECTS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $160.00 $160.00 11/28/18 R41747 1557 CHECK JC FIRE AHI FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $240.00 $240.00 11/28/18 R41747 1557 CHECK JC FIRE AHI Total Paid for FIRE FEES: $400.00 $400.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 11/28/18 R41747 1557 CHECK JC FIRE AHI Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 11/28/18 R41747 1557 CHECK JC FIRE AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$415.00 $415.00 Printed: Thursday, January 12, 2023 2:48:51 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0182 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/12/2018 EDGAR GONZALEZ FSS2018-0182 - HUNTER RESIDENCE - 80-160 VIA PESSARO - FIRE SPRINKLER (CORRECTIONS).docx FSS2018-0182 - HUNTER RESIDENCE - 80-160 VIA PESSARO - FIRE SPRINKLER (CORRECTIONS).docx 1 DOC 12/18/2018 EDGAR GONZALEZ FSS2018-00182 - HUNTER RESIDENCE - 80 -160 VIA PESSARO - FIRE SPRINKLER (COA).docx FSS2018-00182 - HUNTER RESIDENCE - 80 -160 VIA PESSARO - FIRE SPRINKLER (COA).docx 1 DOC 12/9/2021 JOSE DELGADO FSS2018-0182 1ST SUBMITTAL.pdf FSS2018-0182 1ST SUBMITTAL.pdf 0 DOC 12/9/2021 JOSE DELGADO FSS2018-0182 2ND SUBMITTAL.pdf FSS2018-0182 2ND SUBMITTAL.pdf 0 DOC 12/9/2021 JOSE DELGADO Fire Review Application.pdf Fire Review Application.pdf 0 BOND INFORMATION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 11/28/2018 11/29/2018 11/28/2018 COMPLETE 1ST FIRE (2 WK)EDGAR GONZALEZ 11/28/2018 12/12/2018 12/12/2018 REVISIONS REQUIRED SEE CORRECTION NOTICE ATTACHED. 2ND FIRE (2 WK)EDGAR GONZALEZ 12/18/2018 1/2/2019 12/18/2018 APPROVED- CONDITIONS CORRECTIONS SUBMITTED SEE ATTACHED CONDITIONS LETTER. Printed: Thursday, January 12, 2023 2:48:51 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0182 Residential Connection Charge Estimate .March 8, 2018 (.760) 899>593QBill HunterCustomer Name:'^ Parcel No.l Address: t « ! (Phone No, 06-07-09-3777-210^018 Geo. ‘ f• 80160 Via PessarO;-La Quinta ‘696682UD:1 Block No.i [size of lot: f -12,632 !..'sq. ft.Lot No. I Type of Service: 29894-2• • 204 Tract No.i: . □HI □Duplex;Triplex:Apts:R-1: B SWSC:r $ ' WSBFC: I $ SCC:i $ ^ Meter: i $ Meter surcharge:! $ Service:! $ Meter & Service:! $ Backflow: I $ Other;! $ Sewer Lateral:! $ SWSC;!$13,Q110Q./acre0.293,773.19 >Acres:; t $2,436/edu Collection: $2,415/edu, 2,436.00 ;Treatment: 3/4 . inch390.00 Meter Size: | I inch1 'Service Size:! Mprrtf—oo - neuO—S" — '— —^—=/ Tract No. 29894-2, Hideaway. Per Agreement only the SWSC and TFC of SCC Is to be collected. WSBFC has been satisfied. Per Dwg. 31119 a 1" service exists and per Dwg. 31107 a 4" lateral exists.PZ18-8714$6,599.19Total: Fees Approved by;Technician: Ruben Montiel Date; information Supplied By Customer CVWD System Data Domestic Water Demand*Service Connection** 5 , gpm 26.3 . gpmMax. Fiow*= Inlet Pressure Outlet Pressure= Max. Flow=j Min. Pressures-' Fire Sprinkler Demand* Max. Flow=: 32.2 psi 65.37 psi 3;6.31 .psi 26.3 • gpni 3/4 inch32.2 Meter Size = Service Size^ ^ Prior to Pressure Regulating Valve For Calculation Purposes- Service Connection Includes; Service Connection PipesSO', Meter Stop, Meter, Check Vaive & Shut Off Valve - 1 ' „ inc «* Min. Pressure=i psi U hSystem Type; Stand AloneMulti * CVWD USES WORST CASE CONDITION 3/4 " METER • itCalculations: L'ake Cahuilia USE 1 SERVICE i. ‘^L^alves etc.=I NO C58195 Maxlflow '.RSt ';p' C psiPz=6065.37 11.17 > 145HGL= RES.#= RES./HT= 32 PROP. ELEV.= 10 67 25 17.89 36.31 26.30 GPM 32.2 psi> I -ir I Ps is OK QK tp provide serviceA/ // LPkd/) M /^/7/'y-?*^^Date;• '^^/'^Tv'T^^VAppoved by: The meter sizing is for plan check purposes only. The'ultjmatejr^sp'onsibility resides with the Engirteer-of-F^cord for the project. TRY: Fire Sprinkler Demand Butlodn 006 September 2018 Reliable Model RFC Series Residential Sprinklers Flat Cover Plate, Cor^cealed Pendent Sprinkler cULus Listed Features • cULus Listed as Residential Sprinklers • Push-On cover plate installation • Low water flow requirements -• • • • # : IProduct Description Mode! RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended (or installation in accofdaice with NFPA 13, NFPA 13R. or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac cordance with UL 1626. In addition. Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL). Model RFC30 & RFC30LL Model RFC43 & RFC43LL Model RFC30. RFC43. and RFC49 sprinklers have a 165‘’F (74'’C) temperature rated fusible-link operating element. Model RFC58 and RFC76 sprinklers are offered with eiiher a ISST (74'’C) or 212'‘F (lOO'C) temperature rated fusible-link operating element. Spxinklers with a 165"F (74'’C) tempera ture rating are ordinary temperature classification and are listed lor use with a 135T (57'"C) temperature rated cover plate. Sprinklers wilh a 212^F f lOOX) temperature rating are intermediate temperature classification aixf are listed for use wiith a 165‘’F (74”C) temperature rated cover plate. Model RFC49 & RFC49LL Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by ei ther pushing or threading the cover plate into the sprinkler cup Model RFC30, RFC30LL. RFC43. RFC43LL. RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjust ment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC cover plates are avail able in a variety of finishes as listed in Table H.Model RFC76 Model RFC Cover Plate Table A Nominal K-Factor gpm/psi’'* (l/min/bar’'*) Max. Coverage Area ft X ft (m X m) Listings & Approvals Sprinkler identification Number (SIN)Sprinkler Model RFC30 3.0 (43)14 X 14(4.3x4.3)RA0611cULus RFC30LL RA32n3.0 (43)14 X 14(4.3X4.3)CULus, LL RFC43 4.3 (62)20x20(6.1 x6.1)RA0612cULus RFC43LL 4.3 (62)20x20(6.1 x6.1)cULus. LL RA3212 RFC49 RA06164.9 (71)20 x 20(6.1 x6.1)cULus FIA3216RFC49LL4.9 (71)20x20(6.1 x6.1)cULus, LL RA0613RFC585.8 (84)20x20(6.1 x6.1)cULus RA0618RFC767.6(109)20x20(6.1 x6.1)CULus cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Prot^lion Service LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex Q (Less than 0.26% Lead content). WWW feliabfesprinkler.com U- RFC30: SINRA0611 RFC30LL: SINRA3211 Model RFC30 & RFC30LL Residential Sprinklers Technical Specifications Style: Flat Concealed Pendent Threads: 1/2’ NPT or ISO 7-1R1/2 Nominal K-Facton 3.0 (43 melric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 6 ft. (2.4 m) Cover Plate Finishes (See Table H) Sensitivity Fasl-response Temperature Rating 165"F(74''C) sprinkler 135'F (57“C) cover plate Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alk^ Yoke: Brass Alloy SeaHng Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector Bronze Alloy Cup: Steel Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrer>chable cap) Model W3 (with wrenchable cap) Bottom ViewListings and Approvals cULus Listed to UL 1626 cULus Certified lor Health Etfects to NSF/iU^SI Standard 61 Annex O (RFC30LL only) Model RFC30 & RFC30LL Sprinkler Components and Dimensions Figure 2-5/16' (56 mm) Dia.Threads Body - - Tower 1-3/4" (44 mm) +/-1/4" (6 mm) Nominal face of fitting to ceihngFusible Link li Deflector (retracted) Pin (extended) Deflector (extended) N N S N N \ S ' WSNN \ V' 3/16" (5 mm) T CeilingModel RFC Cover Plate 3-5/16” (84 mm) Dia. TableModel RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria i Minimum Flow and Residual Pressure Max. Coverage Area<^ ft. xft. (m X m) Row gpm (l/min) Pressure psi (bar) 9.012 X 12 (3.6 X 3.6) 9 (34)(0.62) 11.01014x 14 (4.3 X 4.3)(0.76)(38) Notes: 1. For NFPA 13 installations the flow per sprinkler niust be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density ol 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Page 2 ol 8 WWW fetiabiesprinkler.com Bulletin 006 September 2018 I £igimTi RFC43: SINRA0612 FIFC43LL: SINRA3212 Model RFC43 & RFC43LL Residential Sprinklers Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7.1R1/2 Nominal K-Facton 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165"F (74‘^C) sprinkler 135“F (ST^C) cover plate : Material Specifications Thermal Sensor Nickel Alloy Solder Link I Sprinkler Body: Brass Aioy I Levers: Bronze Alley j Yoke: Brass Alloy I Sealing Assembly: Nickel Alloy with PTFE I Load Screw: Bronze Alloy i Towers: Copper Alloy I Pins: Stainless Steel I Deflector Bronze Alloy i Cup: Steel Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrenchabie cap) Model W3 (with wrenchable cap) Bottom View Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Arviex G (RFC43LL only) Model RFC43 & RFC43LL Sprinkler Components and Dimensions Figure 2-5/16* (58 mm) Dia.Threads 1Body — Cup — Tower - Fusible Link Deflector (retracted) 1-3/4* (44 mm) 1/4* (6 mm) Nominal face of fitting to ceiimg N \ \ \ \ S N ' S \ \ S \ \ S ' \ \ V's V\ V » / / / / ^ / / / i 3/16" (5 mm) £Pin (extended) Deflector (extended) - I I TiIt CeilingModel RPC Cover Plate 3-5/16* (84 mm) Dia.It- TableModel RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure i** Max. Coverage Area ^ ft. xft. (m X m) PressureRow psigpm (bar)(l/min) 12 7,815x 15 (4.6 X 4.6)(45)(0.54) 9.116x 16 (49x4.9) 13 (0.63)(49) 18 17.518x 18 (5.5 X 5.5)(1.21)(68) 23.820x20 (6,1 X 6.1) 21 (79)(1.64) Notas: 1 For NFPA 13 insialialions the flow per sprinkler must be the greater of: (l) the flow listed in Tabie C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the r>exl larger max. coverage area listed. Page 3 of 8 www.reliablesprinkler.com Bulleiin 006 September 2018 £ nFC49: SINRA0616 RFC49LL; SINRA3216 Model RFC49 & RFC49LL Residential Sprinklers •1 Technic^ Specifications Styte: Fiat Concealed Pendent Threads: ^/2' NPToriSO 7-1R1/2 Nominal K-Factor 4.9 (71 metric) Max. Working Pressure; 175 psi (12 bar) Min. Spacing: a ft. (2.4 m) Cover Plate Finishes (See Table H) Sensitivity Fast*response Temperature Rating t65'F(74'’C) sprinkler 135*F (57'C) cover plate Material Specifications Thermal Sensor Nictol Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel MTIector Bronze Alloy Cup: Steel Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrenchabie cap) Model W3 (with wrenchabie cap) Bottorn View Listings and Approvals cULus Listed to UL 1626 cULus Certified for Healih Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions Figure d Threads Body ^ Cup Tower - Fusible Lmk Deflector (retracted) 1-3/4* (44 mm) ♦/-1/4* (6 mm) Nomirtai face of fitting to eeilmg xvvvssv / f r ^ ^ t / ✓y / . 3/16* (5 mm) r Pin (extended) Deflector (extended)T Model RFC Cover Plate 3-6/16* (64 mm) Oia.Ceiling 5Model RFC49 & RFC49LL Sprinkler HydrauHc Desifln Criteria Table Minimum Flow and Residual Pressure'^ Max. Coverage Area<^ ft. xft. (m X m) Flow Pressure psigpm (l/min)(bar) 16x 16 (4.9x49) 13 7.0 (49.0)(0.48) 13x 18 (5.5 x 5.5) 17 12.0 (64,3)(0.83) 20x20 (6.1 x6.1) 20 16.7 (75.7)(1.15) Notes: 1 For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpnVsq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max coverage area listed. Bulletin 006 September 2016 Page 4 ot 8 WWW reiiablesprinkler.comBfelinblc Model RFC58 Residential Sprinkler SIN RA0613 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2”NPTorlSO 7-1R1/2 Nominal K’Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 Oar) Min. Spacing: 6 ft. (2.4 m) Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165*F (74°C) sprinkler ISS^F (57''C) cover plate Intermediate; 2l2'’F(100“C) sprinkler 165*F (74®C) cover plate Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Brc^e Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Slair>less Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Model RFC Cover Plate Sprinkler Wrench Model FC Bottom View Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions Figure 4 ^ 2-5/16" (58 mm) Dia. Threads Body Cup Tower rp T 1-7/8" (48 mm) ♦/- 3/8* (9 mm) Nominal face of fitting to ceilingFusible Lmk — Deflector (retracted) Pm (extended) Deflector (extended) - W N \ S V, S ' VSNN' S \ S \ \ \ S ' 3/16* <5minj/ / / ^ / / / i £ Hf T Model RFC Cover Plate 3-5/16" (84 mm) Dia.Ceiling TableModel RFC58 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure**’ Max. Coverage Area ^ ft. xft. (m X m) Flow gpm (l/min) Pressure psi (bar) 7.616 X 16 (4.9 X 4.9) 16 (0.53)(60.6) 18x 18 (6.5 X 5.5) 18 9.6 (0.66)(68.1) 20x20 (6.1 x6.1) 20 11.9 (0.82)(75.7) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow Nsted in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq fl over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Page 5 of 8 wvw/.reliablesprinkler.com Bulletin 006 September 2018 iETITFrai Model RFC76 Residential Sprinkler SIN RA0618 Technical Specifications Style: Flat Concealed Pendent Threads: 3/4" NPT or ISO 7-1R3/4 Nominal K*Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165“F(74“C) sprinkler 135"F (ST^C) cover plate Inlemiediate: 212“F(100''C) Sprinkler 165°F (74"C) cover plate Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: BrcKize Alloy Yoke: Brass Alloy Sealing Assembly: Nkkel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Sleel Cover Plate Model RFC Cover Plate Sprinkler Wrench Model FC Bottom View Ustir>gs and Approvals cULus Listed Model RFC76 Sprinkler Components and Dimensions Figure -j ^ 2-5/16* (58 mm) ^ Dia. Threads Body Cup Tower i vV bsy*—!1 -7/8’ (48 mm) +/- 3/8* (9 mm) Nominal face of fitting to ceiling f'r -[[1 'J t>i| i Fusible Link t Deflector (retracted) Pin (extended) Deflector (extended) 3/16* (6 mm) n n tf Sf H ■#' .Y i 3-5/16* (84 mm) Dia.CeilingModel RFC Cover Plate TableModel RFC76 Flat Concealed Sprinkler Hydraulic Design Criterta Minimum Flow and Residual Pressure^') Max. Coverage Area (m X m) Flow gpm (l/mln) Pressure psi (bar) 7.6I6x 16 (4.9 X 4.9) 21 (0.52)(79.5) 9.918x 18 (5.5 X 5.5) 24 (0.68)(90.8) 2020x20 (6.1 X 6.1) 34 (128.7)(1.4) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. !?r For coverage area dimensions less than those listed above, use the minimum required flow tor the next larger metx. coverage area listed. Page 6 of 8 www.reliablespfinkler.comI£Bulletin 006 September 2018 mi FIT Cover Plate Finishes''’Table H Standard Finishes Sp6<>ial Application Finishes White Polyester OK White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad'-"Custom Color Painf Notes: I - i „ , 1. Paint or any other coating applied over the factory finish will void ail approves and warranties. 2. Custom color paint is semi-gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side. Cover plates are not listed or approved as corrosion resistant. Stainless steel dad cover plates are not available perforated. Installation Dimensions Table d Min. to Max. Dropped Deflector Distance below Ceiling inch (mm) Min. to Max. Face of Fitting to Ceiling*'’ inch (mm) Recommended Hole Diameter in Ceiling inch (mm) Cover Plate Diameter inch (mm) Cover Plate Adjustment inch (mm) Cover Plate Model Cover Plate Temperature Rating Sprinkler Model RFC30. RFC30LL. RFC43. RFC43LL. RFC49. RFC49LL 3-5/16 2-5/8 1/2 1-1/2 to 2 (38 to 51) 1/2 to 1 (13 to 25) 135‘'F (57"C)RFC (84)(67)(13) 135T'^' RFC58. RFC76 3-5/16 2-5/8 3/4 M/2 to 2-1/4 (38 to 57) 1/4 to 1 (6 to 25) (57''C)RFC or 165^'P^'(84)(67)(19) (74-C) Notes: 1. Face of filling to celling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2’ x 1/2’ brass nipple extension (Reliable P/N 6999991900) is available where necessary (or replacement of existing sprinklers. 2. For use with 165®F (74®C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100®F (38®C}. 3. For use with 212®F (100*C) temperature rated sprinklers with (he Maximum Ceiling Temperature does not exceed 160®F (66*’C). Installation Model RFC series sprinklers are intended to be installed in ac cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a protective cap that should remain on the sprinkler until installed. The fxotective cap should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover ii^ate by hand by pushing the cover plate into the cup and turning the cover in the clockvwse direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13. NFPA 13R, and NFPA 130. The sprinklers are concealed pen dent residential sprinklers. Model RFC series sprinklers are installed with the Model FC wrench. The use of any other wrench to installed Model RFC se ries sprinklers is not permitted and may damage the sprinkler. Temporarily remove the protective cap during installation of the sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model FC wrench is designed to be turned with a standard 1/2" square drive. Tighten the sprin kler into the fitting after applying a PTFE based thread sealant to the sprinkler’s threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4" thread sprinklers. Model RFC 30. RFC30LL. RFC43. RFC43LL. RFC49 and RFC49 LL sprinklers are available in ordinary temperature classifica tion for installation where the Maximum Ceiling Temperature does not exceed lOO ’F (38''C). Model RFC58 and RFC76 sprin klers are available in either ordinary or intermediate tempera ture classification for installation where the Maximum Ceiling Temperature does not exceed 1(X)"F (38‘'C) or 150"F (66'^C). respectively. Page 7 of 8 www.reliablesprinkter.com Bulletin 006 September ^18 Wrench iV L<»Model FC For use with Models RFC30. RFC43. and RFC 49 without wrenchable cap and Models RFC58 and RFC76 Model W3 For use with Models RFC30. RFC43, and RFC49 with wrenchable cap Maintenance Guarantee Model RFC series sprinklers should be ir\specled and the sprk^kler system maintained in accordance with NFPA 25. Do noi clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A slock of spare sprinklers should be maintained to allow quick replace ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper ation. For the Reliable Automatic Sprinkler Co.. Inc. guarantee, terms, and conditions, visit www.r6ilablesprinkler.com. Patents Model RFC30. RFC30LL. RFC43. RFC43CL, RFC49. RFC49LL. RFC58. and RFC76 sprinklers are covered by U.S. Patent No. 9.248,327 and U.S. Patent No. 7.275,603. Model RFC30, RFC30LL. RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776.903. Listings and Approvals Ordering information Listed by Underwriters Laboratories. Inc, and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-prolection Service (cULus). Certified by Underwriters Laboratories. Inc. and Underwriters Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43a, and RFC49LL only). Specify the following when ordering. Sprinkler • Model (RFC30. RFC30LL. RFC43, RFC43LL RFC49, RFC49LL. RFC58. RFC76) • Temperature Rating Cover Plate • Model RFC • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC • Model W3 5 o Page 8 ol 8 vvww.reltabiesprinKler.coni Bulletin 006 September 2018 1 - u 7 ti/ca F/re <8i Building / Products r m TU HesiRB Faisg Sp^se3GSQ.ii{3 Sv§?ii£^ Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 ^ a Pj O Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are designed exclusively for use In wet pipe automatic fire sprinkler systems. They are made from a speciedly devel oped thermoplastic compound com posed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFBP BlazeMaster CPVC products are easier to Install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as com pared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic pip ing. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. WARMING Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein mustbe Installed and maintained in compliance with this document, as well as with the applica ble standards of the National Fire Pro tection Association, in addition to the standards ofany otherauthorities hav ing jurisdiction. Failure to do so may impair the performance of these de vices. The owner is responsible for maintain ing their fire protection system and de vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sizes 3/4"to 3" Maximum Working Pressure 175 psi Approvais UL. FM. CCUL, NSF, Dade County LPCB, MEA, and the City of Los Ange les. (Refer to IH-1900, Rev. 0, Janu ary 2005 "Installation Instruction & Technical Handbook" for exact iist- ing/approval information.) Manufacture Source U.S.A. Material 0 Pipe: ASTM F442, SDR 13.5 ° Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange BlazeMaste/^ is a registered trademark of Noveon IP Holding Corp. Pag® 1 of 6 JANOAPY, 2006 TFP1915 7 Page 2 of6 WATER FILLED WEIGHT ’lbs./Tt WEIGHT PER UR-NOMINAL FT. OF PIPE PER LIFT AVERAGE WEIGHT lbs./ft. AVERAGE [1^.SIZE O.D.I.D. 3/4"13391.050‘0.874'0.18 0.44 7875 1“13201.315” 1.660" 1.900"- a375''‘ a875" 3.500" 1.101'0.26 0.67 5040 1-1/4" 1-1/2“ 11911.394" 1.598" 2.003" a423“ a952" 0.42 28351.08 0.54 1.41 2205 1213 2"0.84 2.20 1260 1084 2-1/2”15311.26 3.26 1215 3“7201.87 4.83 1344 FIGURE 1 - PIPE DIMENSIONS a a Tyco Fire and Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord ance with lH-1900, Rev. 0, January 2005 “Installation Instruction&Techni- cal Handbook”. The owner Is responsible for the in spection, testing, and maintenance of their fire protection system and de vices in compliance with this docu ment, as well as with the applicable standards of the National Fire Protec tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The In stalling contractor or product manufac turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Bstore closing a fire protection system control valve lor Inspection or mainte nance work on the fire protection sys tem that it controls, permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system In service, notify the proper authorities and advise those responsible for moni toring proprietary and/or central sta tion alarms. V| ^Ti *0 & ,-(n “0 o Co) o &> TFP1915 mriNG TYPE PART NOMINAL 1AKEK)UTNOMINAL SIZE WSGHTNUMBERSCHD.fT/O)Ob.) 4SO E130W T/O-f 60050 60051 80052 60053 80054 80055 80056 3M"3/8'40 0.08 r S/&40 0.11 1-1/4" 1-1/2' 3/4"40 0.20 1/2"80 0.31 2"3/4'80 0.56 2-1/2“13/16*80 0.89 3"1“80 1.19 80075 80076 80077 80078 80079 80080 80081 3/4‘1/8'40 0,07COUPLING & REDUCING COUPLING 1“1^40 0.11 1-1M* 1-1S" 8/16*40 0.12 3/16“80 0.25 2“3/16"80 0.38 2-1/Z*1/4'80 0.67 3“t-T/0 3/16*80 0.91 80220 1"x3/4'1/8"40 0.08 80200 80201 80202 80203 80204 80205 80206 80207 80208 80209 60215 80214 80213 80211 80210 80212 1“x3/4* 1-1/4“x3/4" 1-1/4" XI" 1-1/2" X 3/4“ 1-1/2“ Xl“ 1-1/2“ X1-1/4“ 2“X3/4" 2* XI" 2“ X 1-1/4" 2“ X1-1/2“ 2-1/2“ X1“ 2-1/2“ X1-1/4’ 2-1/2“ X1-1/2“ 2-1/2" X 2“ 3“X2“ S'X 2-1/2" 7/16“40 0.04 1/2“40 0.11 6/16“40 0.12 5/8“80 0.16 REDUCER BUSHING 1/2“60 0.14 3/8“80 0.17 13/16“ 11/16" 80 0.27 80 0.26 9/16“80 0.24 7/16“60 0.19 16/16“ 13/16” 11/16" 80 0.42 80 0.45 80 0.46 Sfff 80 0.29 3/4“80 0.72 1/2“80 0.47 80100 80101 80102 80103 80104 801 OS 60106 CAP 3/4"5^6“40 0.04 1"3«“40 0.06 1-1/4“ 1-1/2’ 7/16"40 0.10 11/16“80 0.20 2” 80 0.31T/O-l 2-1/2*7/8“80 0.58 3“1"80 0.88 GROOVED COUPLING ADAPTER T/0 PIPE O.D. 80160 80161 80162 80163 80164 80169 j-1-1/4“ X1-1/4“ Groove 1-1/2“ X1-1/2" Groove 2“ X 2“ Groove 2-1/2“ X 2-1/2“ Groove S“x3“ Groove 2-1C" X 76.1 mm Groove 2-5/16" 2-6/16" 2-5/16" 2-5fl6’ 2-1/4* 2-5/16" 1-1/4" (1.660") 1-1/2“ (1.900*) 2" (2.375") 2-1/2“ (2.875^ S" (3.S00") 76,1 mm (3.000") 40 0.78 80PIPE 0.95 O.D.80 1.42 L 80 2.28 80 3.001—T/O—J 80 2.28 FIGURE 2 - FnriNQ DIMENSIONS (Pert 2 of 4) RTTINQ PART numbertype NOMINAL flcfS nominal take-out WEIGHTSCHD.(T/O)SPRINKLER HEAD adapter m 80175E 80176E 80175WL 80179 S/4“X1/3*NPT rx1S"NPT 3/4"xiy2*NPT 1'X8/4*NPT 7/16*80 0^0 7/16" 7/16* 13/16" 80 0.22 40 0.16 KT/0 40 0.43 SPRINKLER head adapter 80175W 80176W SAI’xI^NPT 1’x1/2» NPT 1/2* •40 0.19 1/2“40 0.18MVO SPRINKLER HEAD adapter (SPIGOT) 80177L 80176 80180 S/4* X1/8* NPT 1"X1/2*NPT 1"x3/4"NPT 1/2"40 0.16 9/16*40 0.20 -I -T 7/8"40/O 0.40 FEI9ALE ADAPTER 80142 80145 80146 80147 80148 3/4* X 3/4’NPT 1'X1*NPT l-Wx^lM'-NPr 1-1/2*X1.1/2“NPT 2*x?NPT 18/18“40 0.41 7/8*40 0.63 1-1/8'5^.^ n 40 1.03 1-3/B"60 1.42 M70 1-11/16*80 2.66 MALE ADAPTER I 80167 80158 3/4* X 3/4’NPT I'xl’NPT 1-5/16* 1-3ffl* 40 0.33 40 - 0.56 XkYxZ XSPRINKLER HEAD ADAPTER TEE Y Z 80250 80251 80249 60266 80252 80257 80254 80258 80253 3/4“ X 8/4* X1/2" NPT 1*X1"X1/2’NPT 1"xrxl“ NPT 1-1/4* xl-xl/? NPT 1-1/4* X1-1/4" xl/Z* NPT 1-1/2" X1-1/4" X1/2* NPT 1-ia*x1-1/2"x1/2"NPT 2" X1-1/2" X1/2* NPT 2“ X 2* X1/2“ NPT 9/16"9/18"1*40 0.2211/16'T/O 11/16" 15/16* 1-3/16' 1-9/16" 1-6/16" 1-5/16" 1-7/16" 1-7/16" 1-11/16" 1-11/16" 40 0.2915/16“ 40 0.737/16*9n&‘40 0.307/16*7/1®* 11/16* VT 40 0.311/2" 80 0.431/2*1/2"60T/O 0.461/2"5/8"80 0.561/2“1^80 0.62 FIGUHE2 — FITTING DIMENSIONS (Part 3 of 4) Psge 6 cf 6 TFP1915 mriNQ MRT NUMBERTYPE nominal size NOMINAL TAKE-OUT WEIGHTSCHD.(TAJ)(»b.) BACK-T04ACKTEB XxYxZ X Y.Z T/D 60459 60460 rxl/2*NPTxiy?NPT rxl/2* NPTxl/? NPT S/B*1-5/16* i-s/ie* 40 0.46vNVn 5/8' 40 : 0.46 TAD •T/0 BACK-TO-BACK CROSS XxVxZxW X,Y z,w T/0 60462 80463 1'xrx1/2-NPTxl/? NPT I'xl'xl/?- NPTxl/2* NPT 5/8"1-3/16" 1-S/16* 40 0.46 5/9" 40 0.47 Y T/0 ■T/0 TINKLER HEADADAPTER SO* ELBOW XxY X Y Y TO 80199 80196 80196 SM'XI/Z’NPT rxl/2" NPT 1’x3/4*NPT 9/16"1"40 0.203M"xT 1-1/4" 1-7A6" 40 0.261-1/16"40 0.26 l-TO figure 2 -FITTING DIMENSIONS (Part 4 of 4) Limited Warranty by TFBP to be defective shall be either repaired or replaced, at TFBP’s sole neither assumes, norauthorizes any person to assume for Itany other obligation In connection withthe sale of products or parts of prod-ucte. TFBP shall not be responsible forsprinkler system design errors or Inac-curate or Incomplete information sup*plied by Buyer or Buyer’s repre sentatives. ^ fl f merchantability fl nH fitness for » nar.ticmarpiirp«7j:;ft This limited warranty sets forth theelusive remedy for claims based onfailure of or defect In products, materi-as or components, whether the claimIS made in contract, tort, strict Ilabilltv or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, inwhole or part, of any portion of this warranty will not affect the remainder. ex-manufactured by Tyco Fire &Building Products (TFBP) are war-ram^solely to the original Buyer forten (10) years against defects In material and workmanship when paid forand properly installed and maintainedunder normal use and service Thiswarranty will expire ten (10) yearsfrom date of shipment by TFBP. No warranty is given for products or com- companiesnot affiliated by ownership with TFBPor tor products and components which subject to misuse, Impropermallatlon, corrosion, or which havenot been installed, maintained, modl- accordance with ap- p National FireProtection Association, and/or the AuthoritiesHaving Jurisdiction. Materials found TYCO FIRE E BULDINQ PRODUCTS, 45, Nonh Avenue, Lanadale, Penns^vanta In no event shall TFBP be liable ucontract, tort, strict liability or underany other legal theory, for incidentalindirect, special or consequential damages, including but not limited to laborcharges, regardless of whether TFBPwas informed about the possibility of ®''ent shallTFBP 8 liability exceed equal to the sales price. Ifte fgreqninn warranty ic |p .j^..rH other warrflntiftri, nnpress nr implied, incltiding warrapfip;:, In an amount > “ em F8KI SPRAWtOEK P1ISS|M© PSODUCTS» COiPp 2000 DRAIN VALVE Socketx Socket E w D B ^Numb^ 6622-007CO Size C D ESM1-13rt6 Ma 3-9/16 26622010CO 312-1/16 1-3M 4 2-5/16NotULUsted 3-7/16 CPVC SWING CHECK VALVES Soviet X Socket A D i B Part Number 81S20-10CO smieco SItt A B C D Apprex.Wt(Lb8) 1 1-11/16 26/16 4^6 26/8 .331-1rt 2-1rt8 2-1S/16 6-1/2 3e«.42S1S20-15CO 1-1/2 2-7/16 3 666 36/8 idNotULUsted CPVC SPECIAL RHNFORCED THREAD INLET SWING CHECK VALVES SR Fiplx Socket A O i: 1 B Part Number A B C D Approx. Wt (Lbs) S1620-10FSRSCO S162Q-12^(^ 1 1-11/16 2-isn6 4-9^6 26/8 i3l-IM 2-1/16 36/8 5-1/2 3-3/8 A281620-16F8R6CO NotULUsted 1-1/2 2-7/16 3-11/16 5618 36/8 i9 27 SPEARS® MANUFACTURING COMPANY \\Pape Olampi Fig, 28 - "Stand-OfT Hanger & ResSiraDner for OPVC Plastic Pipe & IPS Steel Pipe size Range: — 3/4’ {20mm) through 2' (50mm) Material: — Steel, Pre-Galvanized Function: — Designed to be used as a hanger and restrainer for CPVC piping where the 'standoff design will ease installation by eliminating the need for wood blocking. Features: 0 Flared edge design protects CPVC pipe from any rough or abrasive surfaces. 0 Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation, o The 'Stand-Off design eliminates the need for wood block extension. 0 Can be installed on horizontal or vertical piping regardless of mounting surface orientation, o Attaches easily to wood structure with two hex head self-threading screws furnished with product Installs easily using rechargeable electrical driver with W (7.8mm) extension socket eliminating impact tool damage to pipe, o Attaches easily to steel, minimum 18 gauge (1.024mm) with (2) V4* x 1' tek type self drilling tapping screws. 0 UL Listed as a hanger and a restralner for fire sprinkler piping. Approvals: — Underwriters Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be Installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) V4’ x 1' tek type screws. Meets and exceeds the requirements of NFPA13,13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8" (9,6mm) composite wood material. Use two Rg. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by: — Rgure number and pipe size. Pat. # 7455,268, Pat. # 7832,248 { I iI v • » I n 1 u •»with reduced spacing, consult factory. Rg.27B ^ (2) Required \f Rg.27B ^ (1) Required ^ High Side of Hanger Application « ■g 1 {. Hanger and RestaintHanger Application Application Pipe Size Part No. In, (nun) -2SJ/4 '■ -3/4' '(20) 1' (25) 28-11/4 11/4" (32) 2B-11A 11/2" (40) 2" (50)28-2 A B C Max Hanger Spacing ft (m) Vlft/100 Ib$. (hg)In. (onn)In. (min) ' 31/32" (77.0) ‘ SS/ieT (84.1) 35/8" (911) 4" (101.6) 31/2" (88.9) 31/2' (88.9) ‘ 3l/2"':;(8W) 31/f (88.9) ■ 35/8' 19”2.1): • 2" (SOi) 23/IB: (55.6) 23/8“ (603) 2V2* (63.5) ••' 41/2' (1143) • . 211/16" (683) 51/2 (1.67) 6 (1.83) .61/2 (1.98) 7 (2.13) . ' 8 (2.44) 18 (8.1) 21 (93) 23 (10.4} 31 (143) .VU (15.4) All dimensions in charts and on drawings are In inches. Dimensions shown in parentheses are in millimeters unless otherwise spewfiei-Una Fire Protection Solu'40by 7** ,C Fig. ^ - Double Offset Hanger Restrainer for CPVC PBastic Pipe & IPS Steel Pipe msize Range; Available in 3/4* KOmm) and 1' (26mm) pipe sizes Material: Pre-Galvanized Steei , Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkier pipe. Provides double offset IV2" (20mm) x 1V2" (20mm) from mounting surface. This design wiii ease Installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: o Thumb tab provides protection to restrain pipe In rough job site conditions Tab IS not required to be bent for listed installation. 0 Offset edge eliminates abrasion. 0 Attaches easily to wood structure with two special #10 x 1" hex head self-threading screws furnished vwth product, o Can be used as a single offset hanger by aligning 'dimples* with top of mounting surface and utilizing two fasteners in two of the three holes provided. ^provalK Underwriters Laboratories Usted In-the USA (UL) and Canada (cUL) as a of Nto" 3 ^ 13R a"nd 1 requirements Finish: Pre-Galvanized Order By: Figure number and pipe size. Patent Pending c’! 1.5" {38.1mm) I u. '^9 r' «*With reduced spacing, consult factory. I A 'r. 4,0.. 1.5" (38.1 mm) I *15 Q y \ L Double Offset I Single Offeet ^,1 IrrSL nrAwinln 1^ iif^ ® ® ® attachment with the special hex head self-tappingthTq^AWQ^n thL m ^ screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of^^ ^ nnounpng surface. Thumb tab may be bent up to provide additional protection to the pipe, but is notrequired for performance of the hanger / restrainer function. ^ All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specifis B-UneI Page 1 of 5I NIKING FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services; 877-384-5464 Fax: 269-818-1680 Email; techsvcs@vikingcorp.com DESCRIPTION Viking Freedom* Residential Pendent Sprinkler VK470 is a thermosensitive, glass-bulb residen tial sprinkler available in several different finishes and temperature ratings to meet varying de sign requirements. The Electroless Nickel PTFE (ENT) coating has been investigated for instal lation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Chart. The sprinkler orifice design, with a K-Factor of 3.0 (43.2 metric*), allows efficient use of available water supplies for the hydraulically designed fire-protection system. The glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. LISTINGS AND APPROVALS c®M (C-UL-US-EU): Category VKKW Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed. EU 1. 2. 3. TECHNICAL DATA Specifications: Avaiilable since 2012. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 3.0 U.S. (43.2 metric*) ’ Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 "F (-55 “C) Overall Length: 2-1/4” (58 mm) Material Standards: Frame Casting: QM Brass Deflector: Phosphor Bronze UNS-C51000 or Brass UNS-C23000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For ENT coated sprinklers: Belleville spring - Exposed. Screw and Pipcao - ENT plated. Ordering Information; (Also refer to the current Viking price list.) Sprinkler; Base Part No. 17147 Order Sprinkler VK470 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera ture rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 155 T (68 "C) = B, 175 'F (79 X) = D For example, sprinkler VK470 with a Brass finish and a 155 °F (68 "C) temperature rating = Part No. 17147AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories; (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrenches; A. Standard Wrench: Part No. 10896W/B (available since 2000) B. Wrench for Recessed Sprinklers: Part No. 16036W/B*' (available since 2011) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010.) ”A Yi" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1” diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) Form No. F 061011 Rev 14.1 Viking Technical Data may be found on The Viking Corporation's Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. (Added EU Listing) Page 2 of 5 MIKING FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection. Testing and Maintenance requirements. 7. AVAILABILITY The Viking Model VK470 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES [GeHih^TemperaturesiiCIassiflcationl 100 "F (38 “C)155 T (68 “C)RedOrdinary 150 T (65 X)Yellow175 T (79 “C)Intermediate Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion Resistant Coatings^: ENT Footnotes ’ The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat ible with or suitable for the proposed environment. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with ENT coating. Wrench Flats Protective Sprinkler Cap 10896 Figure 1: Standard Sprinkler Wrench 10896W/B ■ormNo. F 061011 Rov11.1 Page 3 of 5 MIKING FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com n S2E11@Jed2 '!aaig]\!5{is5!&Gi]a0i 0 «isy 4ERe 1 Overall LengthNPT Thread Size Nominal K-Factor Maximum Water Working Pressure Sprinkler Base Part Number 1 SIN metric ^InchesInchesU.S.mmmm 175 psi (12 bar)2-1/4 58153.0 43.2VK4701/217147 Ordinary Temp Rating (155 “F/eS X) Intermediate Temp Rating (175‘’F/79 X)Listings and Approvals ^ Minimum Spacing Max. Coverage Area * Ft.X Ft. (m X m) Deflector Installation Typeto Ft.Pressure^Flow^ GPM (L/min) Pressure*Flow* GPM (L/min) Ceiling (m)NYC NSFPSIPSI (bar)(bar)lU standard surface- mounted escutch eons, the Microfast® Model F-1 Adjustable Escutcheon, or recessed with the Micromatic® Model E-1. E- 2. or E-3 Recessed Escutcheon 7.11 8 7.11812X12 (3.7 X 3.7)(0.49)(30.3)(0.49)(30.3) See Footnotes 6 and 9 See1011.1114X 14 (4.3 X 4.3) 10 11.11 81-1/8 to 2 inch Foot note 7 (0.77)(37.9)(0.77)(37.9)(2.4) 18.818.8 1316X 16 (4.9 X 4.9) 13 (49.2)(1.29)(49.2)(1.29) Footnotes Part number shown is the base part number. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K- factor shown by 10.0. 5 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. * For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. ® Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. ® Approved Finishes are; Brass, Chrome, White Polyester, and Black Polyester ®. ^ Meets New York City requirements, effective July 1, 2008. Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. ® Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. 1 e Form No. F 061011 Rev 14.1 Page 4 of 5 MIKING FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269*945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com MDESiGNILklilibkIAjP [(^soTreferitSlth'e^ApprovallGlTaft^y UL Listing Requirements fC»UL-US-Elh: When using Viking Residential Pendent Sprinkler VK470 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The mini mum required discharge from each of the four sprinklers Is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA13R applications for each listed area of coverage, • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. \I\/ \I\/ I] A — Sprinkler V/rench 16036V/B** for instaUing recessed sprinkler VK470 ■■A 1/2' rotchet Is required (not avollatole fron VlklngX Carefully slide the wrench sideways around the protective cap, ensuring engage ment with the sprinkler wrench flats. nn S»VsWs I* Figure 2: Wrench 16036W/B for Installing Recessed Sprinkier VK470 Ceiling Opening Sizes 2-5/16' <58.7 nn) mininun 2-1/2' <63.5 nrt) naxinun TT j1/2' RljpiHMiliK<15 nn) INPT 1-1/2' <38.1 nn) Mininun 2' <50.8 nn) Maxinun1-3/4' <44.5 nn) 2-1/4' <58 nn)i1-1/2' <38,1 nn) i Installed with a Microfast Model F-1 Adjustable Escutcheon Installed with a standard 1/8' <3.1 nn) surface-nounted escutcheon Figure 3: Sprinkler VK470 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon <28.7 nn) Form No. F 061011 Rev 14.1 Page 5 of 5 MIKING FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Teiephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Emaii: techsvcs@vikingcorp.com Ceiling Opening Sizes 2-5/16' <58.7 nn) ninirnun E-1/2' <63,5 nn) naxinun 3:. 3 ¨T 1-1/8' <28,6 nn) Mfninun 1-1/8' <28.6 nn) Mininun 2'1-3/4' (44.5 nn) Maxinun <50.8 nn) Max nunt i Installed with a Micronatic Model E-1 Recessed Escutcheon Installed with a threaded Micronatic Model E-E Recessed Escutcheon Figure 4: Sprinkler VK470 Dimensions with the Model E-1 and E-2 Recessed Escutcheons (Added EU Listing)Form No. F 061011 Rev 14.1 (. Fire • Fire Sprinkler Hydraulics Calculation Program Living Water Designs Scottsdale. AZ 85260 Elite Software Development, Inc. HUNTER Page 1 General Project Data Report General Data Project Title: Designed By: Code Reference: HUNTER Vallie Schilt Project File Name: Date: Approving Agency: JCF-HUNTER LF..fiw NOVEMBER 1.2018 T" FITTING = -r RUN Client Name: Address: Company Name: Company Address: Phone: Building Name: Contact at Building: Address Of Building: Phone: City. State Zip Code: Representative: City And State: MASTER 2 HEAD @14X14 Building Owner: Phone at Building: City, State Zip Code;80160 VIA PESSARO LA QUINTA, CA Description Of Hazard: Design Area Of Water Application: Default Sprinkler K-Factor: Inside Hose Stream Allowance: In Rack Sprinkler Allowance: Residential Sprinkler System Type: Maximum Area Per Sprinkler: Default Pipe Material: Outside Hose Stream Allowance: Wet 392 ft2 0.00 K 196 ft2 BLAZEMASTER CPVC 0.00 gpm0.00 gpm 0.00 gpm Sprinkler Specifications Make: Size; RELIABLE Model: Temperature Rating: RFC30 155 F7/16 Water Supply Test Data Source Of Information: Test Hydrant ID:Date Of Test; Hydrant Elevation: Test Flow Rate: Calculated System Flow Rate: Available Residual Pressure At System Flow: 0 ft Static Pressure: Test Residual Pressure: Calculated Inflow Residual Pressure: 36.00 32.00 30.59 psi 26.00 25.02 gpm psi gpm psi 32.28 pSi Calculation Pro^x^ Data Calculation Mode: HMD Minimum Residual Pressure: Maximum Water Velocity: Number Of Active Nodes: Number Of Active Pipes: Number Of Active Sprinklers: Demand 11.12 psi 0.00 ft/s Minimum Desired Flow Density: Maximum Frictional Loss /100 feet; 0.05 gpm/ft® 20.00 psi 13 13 Number Of Inactive Pipes: Number Of Inactive Sprinklers: 37 2 0 Monday, December 10, 2018, 9:53 PM *T Rre - Fire Sprinkier Hydraulics Calculation Program Living Water Designs Scottsdale. AZ 85260 Elite Software Development, Inc. HUNTER Page 2 Fire Sprinkler Output Data Overall Pipe Output Data q (gpm) Q (gpm) Velocity (fps) Type-Grp F. L./ft Pipe-Len. (psi/ft) Fittings Flt-Len. Tot-Len. Beg. Nodal End. KFactor Node (K) Spk/Hose Residual Nom. Dia. Discharge Pressure Inside Dia. (psi) C-Value(gpm) PF-(psi) PE-(psi) PT-(psi) Elevation (feet) (ft) 1 10.00 12.50 BLAZEMASTER CPVC 3.00 0.00 10.00 11.12 10.43 1.00 10.00 10.00 0.01889 9.00 0.397 -1.083 -0.686 ET30.00 1.101 12.00 21.001503.37 0 2 10.00 12.50 BLAZEMASTER CPVC 3.00 0.00 10.01 11.14 10.43 1.00 10.01 0.01892 8.00 0.378 -1.083 -0.704 3 ET0.00 1.101 10.01 12.00 20.001503.37 0 3 12.50 12.50 BLAZEMASTER CPVC 0.00 0.00 0.00 10.43 13.02 1.00 0.00 0.06817 20.02 F2T 27.00 11.00 38.00 2.591 0.000 2.591 4 0.00 1.101 150 6.75 0 4 12.50 12.50 BLAZEMASTER CPVC 0.00 0.00 0.00 13.02 14.57 1.00 9.92 0.01861 9.92 6F4ET 1.550 0.000 1.550 44.30 39.00 83.30 5 0.00 1.101 150 3.34 0 4 12.50 10.50 BLAZEMASTER CPVC 0.00 0.00 0.00 13.02 15.54 0.01921 9F2ET 58.00 28.00 86.00 1.00 10.09 10.09 1.652 0.866 2.518 6 0.00 1.101 01503.40 5 12.50 10.50 BLAZEMASTER CPVC 0.00 0.00 0.00 14.57 17.02 0.00 0.01861 9.92 8F2ET 58.00 27.00 85.00 1.582 0.866 2.448 1.00 7 0.00 1.101 150 3.34 0 6 10.50 10.50 BLAZEMASTER CPVC 0.00 0.00 0.00 15.54 17.02 1.00 0.00 0.01921 10.09 4F4E 45.00 32.00 77.00 1.479 0.000 1.479 7 0.00 1.101 01503.40 7 17.02 18.70 0.00 0.06817 20.02 FE 16.60 1.677 0.000 1.677 10.50 10.50 BLAZEMASTER CPVC 0.00 0.00 0.00 1.00 75 8.000.00 1.101 0 24.601506.75 75 0.00 10.50 0.00 18.70 21.42 1.25 0.00 0.02160 20.02 3F 9.50 0.335 2.382 2.716 6.001000.00 5.00 0.00 1.394 BLAZEMASTER CPVC 15.501504.21 0 FS100 5.00 21.42 24.42 19.99 110 3.00 psi 5.00 0.745 2.165 2.910 24.42 27.33 1.25 0.00 0.03467 20.02 ETC 5.501100.00 5.00 0.00 5.00 1.265 16.00 21.50 120 0.00 0.00 TYPE L COPPER TUBE 150 5.11 0 5.00 0.05237 25.02 3E 3.00 0.628 0.866 1.494 120 0.00 0.00 5.00 27.33 28.82 1.25 9.001300.00 -2.00 0.00 1.265 TYPE L COPPER TUBE 0 12.001506.39 Monday December 10. 2018, 9:53 PM , Fire - Fire Sprinkler Hydraulics Calculation Program Living Water Designs Scottsdale. AZ 85260 Elite Software Oerelopment, Inc. HUNTER Page 3 m Fire Sprinkler Output Data Overall Pipe Ou^uit Data (cont'd) F. L/ft Pipe-Len. (psi/ft) Fittings Fit-Len. Tot-Len. q (gpm) Q (gpm) Velocity (fps) Type-Grp Beg. Nodal End. KFactor Node (K) Spk/Hose Residual Norn. Dia. Discharge Pressure Inside Dia. C-Value(gpm)(psi) PF-(psi) PE-(psi) PT-(psi} Elevation (feet) (ft) 130 0.00 0.03681 25.02 2E 1.767 0.000 1.767 0.00 -2.00 -2.00 SCHEDULE 40 PVC 0.00 28.82 30.59 1.25 40.00 140 0.00 0.00 1.360 8.00 150 5.53 0 48.00 Rtting Legend: F = 45 Degree Elbow, E = 90 Degree Elbow, L = Long Turn Elbow, T = Tee or Cross, B = Butterfly Valve, G = Gate Valve, C = Check Valve Monday, December 10, 2018, 9:53 PM Rre • Rre SprinUer Hydraulics Calculation Program Living Water Designs ' Scottsdale. AZ 85260 Elite Software Development, Inc. HUNTER Page 4 I) Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number: HMD Actual Residual Pressure: HMD Actual GPM: 1 11.12 psi 10.00 gpm Sprinkler Summary Sprinkler System Type: Specified Area Of Application: Minimum Desired Density: Application Average Density: Application Average Area Per Sprinkler: Sprinkler Flow: Average Sprinkler Flow: Wet 392.00 ft2 0.050 gpm/ft^ 0.051 gpm/ft^ 196.00 ft2 20.02 gpm 10.01 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity (In Pipe 7 - 75) Maximum Velocity Pressure (In Pipe 7 - 75 ) 6.75 ft/sec 0.31 psi Allowable Maximum Nodal Pressure Imbalance: Actual Maximum Nodal Pressure Imbalance: Actual Average Nodal Pressure Imbalance: Actual Maximum Nodal Flow Imbalance: Actual Average Nodal Flow Imbalance: 0.0100 psi 0.0065 psi 0.0020 psi 0.0233 gpm 0.0036 gpm Overali Network Summary Number Of Unique Pipe Sections: Number Of Flowing Sprinklers: 13 2 Pipe System Water Volume:13.15 gal Sprinkler Flow: Non-Sprinkler Flow: 20.02 gpm 5.00 gpm Minimum Required Residual Pressure At System Inflow Node: Demand Flow At System Inflow Node: 30.59 psi 25.02 gpm Monday, December 10, 2018, 9:53 PM Fire - Fire Sprinkler Hydraulics Caicuiation Program I Living Water Designs Scottsdale. AZ 85260 Elite teftware Development, Inc. HUNTER Page 5 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph w Q. (D W (/i <X) CL Flowrate(xlOO) gpm Supply Curve Data Static Pressure: 36 psi Test Residual Pressure: 32 psi Test Flow Rate: 26 gpm Demand Curve Data Calculated Residual Pressure: 30.59 psi Calculated Flow Rate: 25.02 gpm Excess Available Residual Pressure At Calculated Flow: 1.69 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 0.00 psi \ Monday, December 10, 2018, 9:53 PM