FSS2019-0028ADDITIONAL SITES
CHRONOLOGY
CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES
NOTE ARMANDO MAGALLON 2/28/2019 2/28/2019
I CALLED APPLICANT 2 TIMES AND WAS NOT ABLE TO LEAVE
VOICEMAIL.
I CHANGED THE STATUS OF PERMIT TO INCOMPLETE
SUBMITTAL SINCE THEY DID NOT ATTACH ANY DOCUMENTS
TO THE PERMIT FOR REVIEW.
REVIEWS HAVE BEEN VOIDED.
I EMAILED APPLICANT AND LET THEM KNOW ATTACHMENTS
WERE NOT RECEIVED.
NOTE KAYLI ALFORD 7/13/2020 7/13/2020
CONTRACTOR CALLED AND REQUESTED INSPECTION.
INFORMED THEM THE PERMIT IS EXPIRED AND AN
EXTENSION REQUEST LETTER AND EXTENSION FEE WOULD BE
REQUIRED PRIOR TO EXTENDING.
Description: RESIDENTIAL 13D DESIGN
Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM
HOMES
Status: FINALED Applied: 2/26/2019 ECON
Parcel No: 777180006 Site Address: 53095 VIA VICENZE LA QUINTA,CA 92253 Approved: 3/26/2019 EGO
Subdivision: TR 29894-2 Block: Lot: 181 Issued: 4/1/2019 JLIM
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 7/22/2020 KHET
Valuation: $10,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details:
Printed: Friday, February 03, 2023 3:22:47 PM 1 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2019-0028
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT ARC MECHANICAL P O BOX 1354 YUCCA VALLEY CA 92286 (760)289-9054 KFOSTERARC@GMAIL.
COM
BILL TO ARC MECHANICAL P.O. BOX 1354 Yucca Valley CA 92286 (760)289-9054 kfosterarc@gmail.com
CONTRACTOR ARC MECHANICAL P O BOX 1354 YUCCA VALLEY CA 92286 (760)289-9054 KFOSTERARC@GMAIL.
COM
OWNER HOBBS AND CARR DEVELOPMENT
CORP
ONE PARK PLAZA IRVINE CA 92614 (760)289-9054
NOTE KAYLI ALFORD 7/13/2020 7/13/2020
EXTENDED PERMIT TO 7/14/20 SO CONTRACTOR CAN PAY
ONLINE.
EXTENSION LETTER RECEIVED AND EXTENSION PAYMENT
RECEIVED. EXTENDED PERMIT 6 MOS.
NOTE KAYLI PIERCE 2/27/2019 2/27/2019
NO ATTACHMENTS RECEIVED. ARMANDO WILL CONTACT
APPLICANT & WILL LET HIM KNOW TO SUBMIT DOCUMENTS
BEFORE CONTINUING PROCESS.
CONDITIONS
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
Credit Card Fee 101-0000-43505 0 $7.47 $7.47 2/26/19 WEB3376 CREDIT ARC MECHANICAL ECON
Total Paid for Credit Card Fee: $7.47 $7.47
FIRE SPRINKLER
SYSTEMS - SINGLE
FAMILY DETACHED
101-0000-42421 0 $160.00 $160.00 2/26/19 WEB3376 CREDIT ARC MECHANICAL ECON
FIRE SPRINKLER
SYSTEMS - SINGLE
FAMILY DETACHED PC
101-0000-42420 0 $240.00 $240.00 2/26/19 WEB3376 CREDIT ARC MECHANICAL ECON
FIRE STAFF - PER HOUR 101-0000-42420 0.25 $40.25 $40.25 7/13/20 WEB5666 CREDIT ARC MECHANICAL ECON
Total Paid for FIRE FEES: $440.25 $440.25
Printed: Friday, February 03, 2023 3:22:47 PM 2 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2019-0028
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
OVERHEAD HYRO EGO 4/11/2019 5/13/2019 PARTIALLY
APPROVED
OVERHEAD ROUGH
PIPING EGO 5/12/2019 6/13/2019 PARTIALLY
APPROVED
OVERHEAD ROUGH
PIPING
EGO 6/13/2019 6/13/2019 APPROVED
OVERHEAD HYRO EGO 6/13/2019 6/13/2019 APPROVED
FIRE FINAL**KHET 7/22/2020 7/22/2020 APPROVED SCAN OF AS-builts to be added
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS REMARKS NOTES
1ST PERMIT TECH (1
DAY)
ARMANDO
MAGALLON
2/26/2019 2/27/2019 2/28/2019 INCOMPLETE
1ST FIRE - ETRAKIT
(2 WK)
EDGAR
GONZALEZ 3/5/2019 3/19/2019 3/26/2019 APPROVED-
CONDITIONS See attached letter of conditions.
PARENT PROJECTS
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 2/26/19 WEB3376 CREDIT ARC MECHANICAL ECON
Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 2/26/19 WEB3376 CREDIT ARC MECHANICAL ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS:$462.72 $462.72
Printed: Friday, February 03, 2023 3:22:47 PM 3 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2019-0028
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 3/4/2019 ARMANDO MAGALLON 1ST SUBMITTAL - PLAN
SET
1ST SUBMITTAL - PLAN
SET.pdf 0
DOC 3/3/2019 EtrakitContractor PAGE 1 Hideaway Lot 181
Residence 01-29-19.pdf 1
DOC 3/3/2019 EtrakitContractor PAGE 2- 3
Hideaway
181sprinklersheet2and3
complete.pdf
1
DOC 3/3/2019 EtrakitContractor 1ST SUBMITTAL -
CALCS/WATER LETTER
Hideaway Lot 181
Residence CALCS.pdf 1
DOC 3/26/2019 EDGAR GONZALEZ
1ST SUBMITTAL - PLAN
SET - FIRE APPROVED
SET.pdf
1ST SUBMITTAL - PLAN
SET - FIRE APPROVED
SET.pdf
1
DOC 3/26/2019 EDGAR GONZALEZ
FSS2019-0028 -
HIDEAWAY LOT 181 - 53
-095 VIA VICENZE - FIRE
SPRINKLER (COA).docx
FSS2019-0028 -
HIDEAWAY LOT 181 - 53
-095 VIA VICENZE - FIRE
SPRINKLER (COA).docx
1
DOC 4/3/2019 EDGAR GONZALEZ
FSS2018-0028 -
HIDEAWAY LOT 181 -
FIRE SPRINKLER OH
CORRECTION NOTICE -
ISSUED 4-4-2019.pdf
FSS2018-0028 -
HIDEAWAY LOT 181 -
FIRE SPRINKLER OH
CORRECTION NOTICE -
ISSUED 4-4-2019.pdf
1
DOC 7/13/2020 KAYLI ALFORD Extension Request
FSS2019-0058.pdf
Extension Request
FSS2019-0058.pdf 0
BOND INFORMATION
Printed: Friday, February 03, 2023 3:22:47 PM 4 of 4
Permit Details
City of La Quinta
PERMIT NUMBER
FSS2019-0028
HIDEAWAY LOT 181 RESIDENCE
Fire Sprinkler Reports
for
CLOSET / BATH 2
(2 SPRINKLERS)
Prepared By:
KIRTH FOSTER
ARC MECHANICAL
P.O. BOX 1354
YUCCA VALLEY, CA 92284
760-289-9054
JANUARY 29, 2019
Elite Software Development, Inc.
HIDEAWAY LOT 181 RESIDENCE
Page 2
General Project Data Report
General Data
Project Title: HIDEAWAY LOT 181 RESIDENCE Project File Name: CLOSET..fiw
Designed By: KIRTH FOSTER Date: JANUARY 29, 2019
Code Reference: NFPA 13D (2016) Approving Agency:
Client Name: CLOSET / BATH 2 Phone:
Address: (2 SPRINKLERS) City, State Zip Code:
Company Name: ARC MECHANICAL Representative: KIRTH FOSTER
Company Address: P.O. BOX 1354 City And State: YUCCA VALLEY, CA 92284
Phone: 760-289-9054
Building Name: HIDEAWAY LOT 181 RESIDENCE Building Owner:
Contact at Building: Phone at Building:
Address Of Building: 53-095 VIA VICENZE City, State Zip Code: LA QUINTA, CA 92253
Project Data
Description Of Hazard:RESIDENTIAL Sprinkler System Type:Wet
Design Area Of Water Application: 512 ft² Maximum Area Per Sprinkler:256 ft²
Default Sprinkler K-Factor:4.90 K Default Pipe Material: BLAZEMASTER CPVC
Inside Hose Stream Allowance:0.00 gpm Outside Hose Stream Allowance:5.00 gpm
In Rack Sprinkler Allowance:0.00 gpm
Sprinkler Specifications
Make:VIKING Model:VK494
Size:1/2"Temperature Rating:155 F
Water Supply Test Data
Source Of Information: CVWD
Test Hydrant ID: Date Of Test: 01-17-19
Hydrant Elevation: 0 ft Static Pressure: 76.84 psi
Test Flow Rate: 0.00 gpm Test Residual Pressure: 0.00 psi
Calculated System Flow Rate: 31.08 gpm Calculated Inflow Residual Pressure: 53.23 psi
Calculation Project Data
Calculation Mode:Demand
HMD Minimum Residual Pressure: 7.04 psi Minimum Desired Flow Density:0.05 gpm/ft²
Number Of Active Nodes:13
Number Of Active Pipes:12 Number Of Inactive Pipes:0
Number Of Active Sprinklers:2 Number Of Inactive Sprinklers:0
Elite Software Development, Inc.
HIDEAWAY LOT 181 RESIDENCE
Page 3
Fire Sprinkler Input Data
Node Input Data
Node
No.
Node Description
Branch Description
Area Group
Branch Dia.
(in)
Sprinkler
KFactor (K)
Branch Len.
(ft)
Pressure
Estimate (psi)
Branch Stnd
Fittings
Node Elev (ft)
Branch Non-
Stnd Fittings
(ft)
Non-Sprinkler
Flow (gpm)
Branch Sprk
KFactor (K)
1 Sprinkler
----
----
0.000
4.90
0.0
7.04
----
9.00
0.0
0.00
0.00
2 Sprinkler
----
----
0.000
4.90
0.0
7.13
----
9.00
0.0
0.00
0.00
5 No Discharge
----
----
0.000
N/A
0.0
7.76
----
9.50
0.0
0.00
0.00
10 No Discharge
----
----
0.000
N/A
0.0
18.93
----
10.50
0.0
0.00
0.00
15 No Discharge
----
----
0.000
N/A
0.0
30.49
----
10.50
0.0
0.00
0.00
20 No Discharge
----
----
0.000
N/A
0.0
40.47
----
10.50
0.0
0.00
0.00
50 No Discharge
----
----
0.000
N/A
0.0
42.70
----
10.50
0.0
0.00
0.00
55 No Discharge
----
----
0.000
N/A
0.0
47.05
----
2.00
0.0
0.00
0.00
60 Non-Sprinkler
----
----
0.000
N/A
0.0
47.93
----
1.00
0.0
5.00
0.00
70 No Discharge
----
----
0.000
N/A
0.0
50.37
----
-3.00
0.0
0.00
0.00
80 No Discharge
----
----
0.000
N/A
0.0
50.87
----
-3.00
0.0
0.00
0.00
90 No Discharge
----
----
0.000
N/A
0.0
52.88
----
-3.00
0.0
0.00
0.00
100 No Discharge
----
----
0.000
N/A
0.0
53.23
----
-3.00
0.0
0.00
0.00
Elite Software Development, Inc.
HIDEAWAY LOT 181 RESIDENCE
Page 4
Fire Sprinkler Output Data
Overall Node Groupings Output Data
Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance
Beg.
Node
End.
Node
Type
Group
Flow Rate
(gpm)
At Beg. Node
(gpm)
Out (+)
(gpm)
In (-)
(gpm)
Residual
Pressure (psi)
Flow At Beg.
Node (gpm)
1 5 0 -13.00 13.00 0.00 0.00 7.04
2 5 0 -13.08 13.08 0.00 0.00 7.13 0.00044
5 1 0 13.00 0.00 0.00 0.00 7.76 -0.00004
5 2 0 13.08
5100 -26.08
10 5 0 26.08 0.00 0.00 0.00 18.93 0.00000
10 15 0 -26.08
15 10 0 26.08 0.00 0.00 0.00 30.49 0.00000
15 20 0 -26.08
20 15 0 26.08 0.00 0.00 0.00 40.47 -0.00002
20 50 0 -26.08
50 20 0 26.08 0.00 0.00 0.00 42.70 -0.00002
50 55 0 -26.08
55 50 0 26.08 0.00 0.00 0.00 47.05 -0.00001
55 60 0 -26.08
60 55 0 26.08 0.00 5.00 0.00 47.93 0.00014
60 70 0 -31.08
70 60 0 31.08 0.00 0.00 0.00 50.37 -0.00001
70 80 0 -31.08
80 70 0 31.08 0.00 0.00 0.00 50.87 0.06024
80 90 0 -31.02
90 80 0 31.02 0.00 0.00 0.00 52.88 -0.06025
90 100 0 -31.08
100 90 0 31.08 0.00 0.00 -31.08 53.23
Elite Software Development, Inc.
HIDEAWAY LOT 181 RESIDENCE
Page 5
Fire Sprinkler Output Data
Overall Pipe Output Data
Beg.
End.
Node
Nodal
KFactor
(K)
Elevation
(feet)
Spk/Hose
Discharge
(gpm)
Residual
Pressure
(psi)
Nom. Dia.
Inside Dia.
C-Value
q (gpm)
Q (gpm)
Velocity
(fps)
F. L./ft
(psi/ft)
Fittings
Type-Grp
Pipe-Len.
Fit-Len.
Tot-Len.
(ft)
PF-(psi)
PE-(psi)
PT-(psi)
1 4.90 9.00 13.00 7.04 1.00 13.00 0.03068 11.50 0.936
5 0.00 9.50 0.00 7.76 1.101 13.00 2ET 19.00 -0.217
BLAZEMASTER CPVC 150 4.38 0 30.50 0.719
2 4.90 9.00 13.08 7.13 1.00 13.08 0.03104 8.25 0.846
5 0.00 9.50 0.00 7.76 1.101 13.08 2ET 19.00 -0.217
BLAZEMASTER CPVC 150 4.41 0 27.25 0.629
5 0.00 9.50 0.00 7.76 1.00 0.00 0.11127 56.33 11.608
10 0.00 10.50 0.00 18.93 1.101 26.08 4E3T 48.00 -0.433
BLAZEMASTER CPVC 150 8.79 0 104.33 11.175
10 0.00 10.50 0.00 18.93 1.00 0.00 0.11127 63.83 11.553
15 0.00 10.50 0.00 30.49 1.101 26.08 4ET 40.00 0.000
BLAZEMASTER CPVC 150 8.79 0 103.83 11.553
15 0.00 10.50 0.00 30.49 1.00 0.00 0.11127 70.75 9.986
20 0.00 10.50 0.00 40.47 1.101 26.08 FT 19.00 0.000
BLAZEMASTER CPVC 150 8.79 0 89.75 9.986
20 0.00 10.50 0.00 40.47 1.00 0.00 0.11127 11.00 2.225
50 0.00 10.50 0.00 42.70 1.101 26.08 E 9.00 0.000
BLAZEMASTER CPVC 150 8.79 0 20.00 2.225
50 0.00 10.50 0.00 42.70 1.25 0.00 0.03526 8.50 0.670
55 0.00 2.00 0.00 47.05 1.394 26.08 C 10.50 3.681
BLAZEMASTER CPVC 150 5.48 0 19.00 4.350
55 0.00 2.00 0.00 47.05 1.25 0.00 0.05658 2.00 0.447
60 0.00 1.00 5.00 47.93 1.265 26.08 ET 5.90 0.433
TYPE L COPPER 150 6.66 0 7.90 0.880
60 0.00 1.00 5.00 47.93 1.25 5.00 0.07827 6.00 0.704
70 0.00 -3.00 0.00 50.37 1.265 31.08 EG 3.00 1.732
TYPE L COPPER 150 7.94 0 9.00 2.436
70 0.00 -3.00 0.00 50.37 2.00 0.00 0.00751 60.00 0.505
80 0.00 -3.00 0.00 50.87 2.047 31.08 E 7.22 0.000
SCH. 40 PVC 150 3.03 0 67.22 0.505
80 Meter -3.00 50.87 31.02
90 2.00 psi -3.00 52.88
90 0.00 -3.00 0.00 52.88 2.00 0.00 0.01080 30.00 0.345
100 0.00 -3.00 0.00 53.23 1.900 31.08 TG 2.00 0.000
TYPE K COPPER 150 3.52 0 32.00 0.345
Elite Software Development, Inc.
HIDEAWAY LOT 181 RESIDENCE
Page 6
Fire Sprinkler Output Data
Overall Pipe Output Data (cont'd)
Beg.
End.
Node
Nodal
KFactor
(K)
Elevation
(feet)
Spk/Hose
Discharge
(gpm)
Residual
Pressure
(psi)
Nom. Dia.
Inside Dia.
C-Value
q (gpm)
Q (gpm)
Velocity
(fps)
F. L./ft
(psi/ft)
Fittings
Type-Grp
Pipe-Len.
Fit-Len.
Tot-Len.
(ft)
PF-(psi)
PE-(psi)
PT-(psi)
Fitting Legend: F = 45 Degree Elbow, E = 90 Degree Elbow, L = Long Turn Elbow, T = Tee or Cross, B = Butterfly Valve, G = Gate
Valve, C = Check Valve
Elite Software Development, Inc.
HIDEAWAY LOT 181 RESIDENCE
Page 7
Fire Sprinkler Output Data
Overall Sprinkler Output Data
Flowing
Sprinkler
Node No.
Area Group
Code
Sprinkler
KFactor (K)
Sprinkler
Elevation
(feet)
Residual
Pressure
(psi)
Flowing
Area (ft²)
Flowing
Density
(gpm/ft²)
Sprinkler
Discharge
(gpm)
1 4.90 9.00 7.04 256.00 0.051 13.00
Sub Totals For Non-Group 256.00 0.051 13.00
2 4.90 9.00 7.13 256.00 0.051 13.08
Sub Totals For Non-Group 256.00 0.051 13.08
Totals For All Groups 512.00 0.051 26.09
Elite Software Development, Inc.
HIDEAWAY LOT 181 RESIDENCE
Page 8
Fire Sprinkler Output Summary
Hydraulically Most Demanding Sprinkler Node
HMD Sprinkler Node Number:1
HMD Actual Residual Pressure:7.04 psi
HMD Actual GPM:13.00 gpm
Sprinkler Summary
Sprinkler System Type:Wet
Specified Area Of Application:512.00 ft²
Minimum Desired Density:0.050 gpm/ft²
Application Average Density:0.051 gpm/ft²
Application Average Area Per Sprinkler:256.00 ft²
Sprinkler Flow:26.09 gpm
Average Sprinkler Flow:13.04 gpm
Flow Velocity And Imbalance Summary
Maximum Flow Velocity ( In Pipe 20 - 50 )8.79 ft/sec
Maximum Velocity Pressure ( In Pipe 20 - 50 )0.52 psi
Allowable Maximum Nodal Pressure Imbalance:0.0100 psi
Actual Maximum Nodal Pressure Imbalance:0.0096 psi
Actual Average Nodal Pressure Imbalance:0.0026 psi
Actual Maximum Nodal Flow Imbalance:-0.0602 gpm
Actual Average Nodal Flow Imbalance:0.0093 gpm
Overall Network Summary
Number Of Unique Pipe Sections:12
Number Of Flowing Sprinklers:2
Pipe System Water Volume:26.84 gal
Sprinkler Flow:26.09 gpm
Non-Sprinkler Flow:5.00 gpm
Minimum Required Residual Pressure At System Inflow
Node:53.23 psi
Demand Flow At System Inflow Node:31.08 gpm
freedom® residential
concealed pendent
sprinkler vk494 (k4.9)
tecHnical data
the viking corporation, 210 n industrial park drive, Hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com
visit the viking website for the latest edition of this technical data page www.vikinggroupinc.com
Page 1 of 5
Form No. F_012116 17.04.20 Rev 17.2
1. description
Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards.
The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated.
2.listinGs and approvals
Ul listed (c-Ul-Us-eU): Category VKKW
Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing
requirements that must be followed.
3.tecHnical dataSpecifications:Minimum Operating Pressure: Refer to the Approval Chart.Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500psi (34.5 bar).Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*)Glass-bulb fluid temperature rated to -65 °F (-55 °C)
* Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric
K-factor shown by 10.0.
material standards:Sprinkler Body: Brass UNS-C84400 or QM BrassDeflector: Phosphor Bronze UNS-C51000Deflector Pins: Stainless Steel UNS-S30200Button: Brass UNS-C36000Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400Compression Screw: 18-8 Stainless SteelYoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-C51000Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE TapeCover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc PlatingShipping Cap: Polyethylenecover plate materials:Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800Spring: Beryllium NickelSolder: Eutecticordering information: (Also refer to the current Viking price list.)Viking Freedom® Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately:sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for thetemperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JNTemperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = EFor example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE.cover plate assembly: Base Part No. 13504 (2-3/4” diameter), Base Part No. 13642 (3-5/16” diameter), or Base Part No. 15394(square cover plate, 3-5/16” diameter)
Replaces Form No. F_012116 Rev 17.1
(added alt. material for yoke)
freedom® residential
concealed pendent
sprinkler vk494 (k4.9)
tecHnical data
the viking corporation, 210 n industrial park drive, Hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com
visit the viking website for the latest edition of this technical data page www.vikinggroupinc.com
Page 2 of 5
Form No. F_012116 17.04.20 Rev 17.2
Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number:Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/BTemperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA.
available finishes and temperature ratings: Refer to Table 1.
accessories: (Also refer to the Viking website.)sprinkler Wrenches**:A. Heavy Duty Part No. 14047W/B** (available since 2006), orB. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007)D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007)
**Requires a ½” ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets.
sprinkler cabinet: Part No. 01731A (available since 1971)
4. installation
Refer to appropriate NFPA Installation Standards.
5. operation
During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. . Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres-sure at the sprinkler to extinguish or control the fire.
6. inspections, tests and maintenance
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
7. availability
Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation
web site for the closest distributor or contact The Viking Corporation.
8. GUarantee
For details of warranty, refer to Viking’s current list price schedule or contact Viking directly.
table 1: available sprinkler temperatUre ratinGs and finisHes
sprinkler
temperature
classification
sprinkler
nominal
temperature
rating1
maximum
ambient
ceiling
temperature2
temperature rating
of the cover
assembly
(required)3
cover
plate
base part
number4
large
cover plate
base part
number4
square
cover plate
base part
number4
bulb color
Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C)13504 13642 15394 Red
Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C)13504 13642 15394 Green
sprinkler finishes: Brass and ENT
cover plate finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black
corrosion resistant coatings5: ENT
footnotes
1 The sprinkler temperature rating is stamped on the deflector.
2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having
Jurisdiction. Refer to specific installation standards.
3 Maximum ambient temperature for cover assembly is 100 °F (38 °C).
4 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule.
5 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and
do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed
environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring
is exposed.
freedom® residential
concealed pendent
sprinkler vk494 (k4.9)
tecHnical data
the viking corporation, 210 n industrial park drive, Hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com
visit the viking website for the latest edition of this technical data page www.vikinggroupinc.com
Page 3 of 5
Form No. F_012116 17.04.20 Rev 17.2
approval chartviking vk494, 4.9 k-factor residential concealed pendent sprinkler
for systems designed to nfpa 13d or nfpa 13r. for systems designed to nfpa 13, refer to the design criteria. for ceiling types refer to
current editions of nfpa 13, 13r or 13d
sprinkler base
part number 1 sin npt thread size nominal k-factor maximum Water Wor-
king pressureinchesmmU.s. metric
2
20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar)
max. coverage
area 6
W X l
ft. X ft.
(m X m)
flow
Gpm
(lpm)
pressure
psi (bar)Deflector to
ceiling
installation
type
listings and
approvals3,5
minimum
spacing
ft.
(m)155 °F (68 °C), 200 °F (93 °C) Temperature
Rated Sprinklers
4
12 X 12
(3.7 X 3.7)
13
(49.2)
7.0
(0.48)
Refer to Figure 2
Concealed with
Cover Plate
Assembly.
See Footnote 9.
See Footnotes 7,10, & 11 8
(2.4)
14 X 14
(4.3 X 4.3)
13
(49.2)
7.0
(0.48)
16 X 16
(4.9 X 4.9)
13
(49.2)
7.0
(0.48)
18 X 18
(5.5 X 5.5)
17
(64.4)
12.0
(0.83)
20 X 20
(6.1 X 6.1)
20
(75.7)
16.7
(1.15)
footnotes
1 Part number shown is the base part number. For complete part number, refer to current Viking price schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals.
Refer also to Design Criteria.
4 Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union.
5 Meets New York City requirements, effective July 1, 2008.
6 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from
sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used.
7 Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate).
9 Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking
for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3.
10 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or
Painted Black 9.
11 C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT)
freedom® residential
concealed pendent
sprinkler vk494 (k4.9)
tecHnical data
the viking corporation, 210 n industrial park drive, Hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com
visit the viking website for the latest edition of this technical data page www.vikinggroupinc.com
Page 4 of 5
Form No. F_012116 17.04.20 Rev 17.2
desiGn criteria
(Also refer to the Approval Chart on page 3.)
Ul listing requirements (c-Ul-Us-eU):
When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover-age and minimum water supply requirements shown in the Approval Chart.
For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following:
• The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or
• Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13.
• Minimum distance between residential sprinklers: 8 ft. (2.4 m).
note: concealed sprinklers must be installed in neutral or negative pressure plenums only.
important: always refer to bulletin form no. f_080415 - best practices for residential sprinkler Handling and installation. also refer to form no. f_080614 for general care, installation, and maintenance information. viking sprinklers are to be in-stalled in accordance with the latest edition of viking technical data, the appropriate standards of nfpa and any other similar authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. final approval and acceptance of all residential sprinkler installations must be obtained from the authorities Having Jurisdiction.
sprinkler and adapter assembly
• protective cap removed
• Use wrench 14047W/b**
step 1:
carefully slide the
wrench sideways around
the deflector and pins
sprinkler Wrench
part no. 14047W/b**
** a 1/2” ratchet is required (not available from viking)
2-1/4” (57 mm)
diameter opening
required in the
ceiling.
step 2:
carefully press the wrench upward and
turn slightly to ensure engagement with
the sprinkler wrench flats.
figure 1: sprinkler installation and proper Wrench Usage
never install the sprinkler by applying the installation
wrench across the frame arms. do not overtighten.
Use only the designated sprinkler wrenches, viking
part numbers 14047W/b** or 14031**. a leak tight seal
should be achieved by turning the sprinkler clockwise
1 to 1-1/2 turns beyond finger tight.
sprinkler
wrench flat
sprinkler
frame arms
freedom® residential
concealed pendent
sprinkler vk494 (k4.9)
tecHnical data
the viking corporation, 210 n industrial park drive, Hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com
visit the viking website for the latest edition of this technical data page www.vikinggroupinc.com
Page 5 of 5
Form No. F_012116 17.04.20 Rev 17.2
figure 2: sprinkler dimensions and cover installation
1/2” (15 mm) npt
2-1/4”(58 mm)2-9/16” (65 mm)maximum 2-1/16” (52 mm)minimum
2-3/4” (70 mm) or
3-5/16” (84 mm)note: Upon sprinkler activation, the deflector descends
to approximately 13/16” (21 mm) below the sprinkler body.
figure 3: identification of custom paint for concealed covers
All custom color painted cover plates will have an
identifying label affixed to the inside of the cover that
indicates the custom color and will have a representative
sample (a paint dot) of the paint on the label.FACTORY APPLIE D C USTO
M
P
AI
NT COLORfigure 4: square cover assembly 15394
3-5/16” (84 mm)
Replaces Form No. F_012116 Rev 17.1
(added alt. material for yoke)
Office of the Fire Marshal
City of La Quinta
78-495 Calle Tampico, La Quinta CA 92253
• Phone (760)777-7000 •Direct (760)777-7074
3/26/2019
Kirth Foster
Arch Mechanical
P O Box 1354
Yucca Valley, CA 92286
Re: Residential Fire Sprinkler Plan Review – Hideaway Lot 181
FSS2019-0028
53-095 Via Vicenze
La Quinta, CA 92253
The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside
County Fire Department - Office of the Fire Marshal personnel and are approved with the following
conditions.
Permanently marked identification signs shall be attached to all control valves.
The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff:
(a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating
pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to
contact CPVC piping once insulation is installed.
(b) Final inspection
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777-7131.
SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural
integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable
regulations. Final approval is subject to field inspection.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Edgar Gonzalez
Fire Safety Specialist