FSS2019-0043
ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE KAYLI ALFORD 5/28/2019 5/28/2019 ISSUED JOB CARD TO CHANTEL VASQUEZ NOTE KAYLI ALFORD 5/7/2020 5/7/2020 RECEIVED REQUEST TO EXTEND PERMIT FROM CONTRACTOR. ROUGH/HYDRO INSPECTIONS WERE NOT CLEARED BY FSS EDGAR GONZALEZ IN THE SYSTEM, SO I REQUESTED JOB CARD FROM CONTRACTOR. SEE ATTACHED. UPON ENTERING THE INSPECTIONS IN THE SYSTEM, THE SYSTEM MISTAKENLY EXTENDED PERMIT BY 6 MOS FROM TODAY'S DATE, BUT SHOULD HAVE EXPIRED 11/3/19 (6 MOS FROM DATE OF LAST INSPECTION). I WILL EXTEND THE PERMIT OUT BY 1 DAY FROM TODAY SO THAT CONTRACTOR CAN PAY ONLINE VIA ETRAKIT. SEE EXTENSION REQUEST LETTER ATTACHED. OK TO EXTEND PER KOHL. EXTENSION FEE PAID. PERMIT EXTENDED 6 MOS FROM TODAY. Description: DESIGN & INSTALL AUTO FIRE SPKRS. IN NEW RESIDENCE Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - TRACT HOMES Status: FINALED Applied: 3/29/2019 ECON Parcel No: 770240008 Site Address: 78340 COYOTE CANYON CT LA QUINTA,CA 92253 Approved: 4/18/2019 EGO Subdivision: TR 28470-1 Block: Lot: 50 Issued: 5/28/2019 KAL Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/13/2020 crw Valuation: $19,500.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Tuesday, February 14, 2023 11:35:22 AM 1 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0043 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT John Paulus Paulus 72120 Northshore St. Ste. "C" Thousand Palms CA 92276 (760)404-1350 jpaulus@shastafire.co m BILL TO SHASTA FIRE PROTECTION 72120 Northshore St. Ste. "C" Thousand Palms CA 92276 (760)404-1350 jstahl@shastafire.com CONTRACTOR John Paulus Paulus 72120 Northshore St. Ste. "C" Thousand Palms CA 92276 (760)404-1350 jstahl@shastafire.com OWNER ROBERT ZERBST 72120 Northshore St. Ste. "C" Thousand Palms CA 92276 (760)404-1350 jstahl@shastafire.com CONDITIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY Credit Card Fee 101-0000-43505 0 $7.47 $7.47 3/29/19 WEB3510 CREDIT STAHL, LINDA ECON Total Paid for Credit Card Fee: $7.47 $7.47 FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 5/12/20 WEB5107 CREDIT SHASTA FIRE PROTECTION INC ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $160.00 $160.00 3/29/19 WEB3510 CREDIT STAHL, LINDA ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $240.00 $240.00 3/29/19 WEB3510 CREDIT STAHL, LINDA ECON FIRE STAFF - PER HOUR 101-0000-42420 0.25 $40.25 $40.25 5/7/20 WEB5068 CREDIT SHASTA FIRE PROTECTION INC ECON Total Paid for FIRE FEES: $601.25 $601.25 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 3/29/19 WEB3510 CREDIT STAHL, LINDA ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 Printed: Tuesday, February 14, 2023 11:35:22 AM 2 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0043 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING EGO 6/3/2019 5/7/2020 APPROVED APPROVED BY FSS EDGAR GONZALEZ PER THE ATTACHED JOB CARD OVERHEAD HYRO EGO 6/3/2019 5/7/2020 APPROVED APPROVED BY FSS EDGAR GONZALEZ PER THE ATTACHED JOB CARD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 3/29/19 WEB3510 CREDIT STAHL, LINDA ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$623.72 $623.72 Printed: Tuesday, February 14, 2023 11:35:22 AM 3 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0043 FIRE FINAL**KHET 5/11/2020 5/11/2020 DISAPPROVE D SEE NOTES *REMOTE VIDEO INSPECTION: 1) Water meter was 3/4" when plans calculate for 1" WM. We contacted the superintendent to clarify if there were plans to upgrade, which there is not. 1a) I am requiring at least one bucket test to be performed to confirm the operational adequacy of the 3/4" WM. Bedroom 2 can reasonably no longer be considered a (2) head 20x20 room as there is a 6-inch soffit at the room entry, effectively separating into 2 ceiling heights (compartments) each served by a single head. Minimum 18x18 spacing demand is still necessary here. 1b) I am suggesting (1) head bucket test at this single most remote head needing to meet 18x18 demand requirements. 1c) I am further suggesting (2) bucket test at the 2 heads located in the hall leading to Bedroom 2. Measurement will need to be taken of these 2 heads to identify minimum demand requirements. *Typically 3/4 WM will not allow adequate flow for more than 16x16 (2) head calc. 2) Closet for Bedroom 3 measured 5'x6' and therefore requires a head to be added. FIRE FINAL**KHET 5/13/2020 5/13/2020 APPROVED WITH BUCKET TEST 2-head bucket test revealed 20.8 gpm from each head, meeting the 20x20 spacing required by the 18'9" spacing observed in the remote hallway. (3/4 WM)Replaced 1 of 2 gauges on the riser due to continuous pressure difference between them of 10-15 psi.92 psi static at riser.1-head bucket test revealed 29.3 gpm, meeting the 20x20 spacing required for the room. PARENT PROJECTS Printed: Tuesday, February 14, 2023 11:35:22 AM 4 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0043 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/29/2019 EtrakitContractor FLOW TEST REPORT Flow test.pdf 1 DOC 3/29/2019 EtrakitContractor SPEC SHEETS Spec Sheets.pdf 1 DOC 3/29/2019 EtrakitContractor FIRE SPKR PLANS Zerbst Residence Fire Sprinkler Plans.pdf 1 DOC 3/29/2019 EtrakitContractor HYD CALCS Zerbst Residence Hydo Calcs.pdf 1 DOC 4/18/2019 EDGAR GONZALEZ Zerbst Residence Fire Sprinkler Plans - FIRE APPROVED SET..pdf Zerbst Residence Fire Sprinkler Plans - FIRE APPROVED SET..pdf 1 DOC 4/18/2019 EDGAR GONZALEZ FSS2019-0043 - ZERBST RESIDENCE - 78-340 COYOTE CANYON CT - FIRE SPRINKLER (COA).docx FSS2019-0043 - ZERBST RESIDENCE - 78-340 COYOTE CANYON CT - FIRE SPRINKLER (COA).docx 1 DOC 5/7/2020 KAYLI ALFORD Job Card FSS2019- 0043.pdf Job Card FSS2019- 0043.pdf 0 DOC 5/7/2020 KAYLI ALFORD FSS2019-0043 EXTENSION REQUEST.pdf FSS2019-0043 EXTENSION REQUEST.pdf 0 BOND INFORMATION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 3/29/2019 4/1/2019 4/1/2019 COMPLETE 1ST FIRE (2 WK)EDGAR GONZALEZ 3/29/2019 4/12/2019 4/18/2019 APPROVED- CONDITIONS SEE ATTACHED CONDITIONS OF APPROVAL. Printed: Tuesday, February 14, 2023 11:35:22 AM 5 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0043 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/11/2020 KOHL HETRICK FSS2019-0043 - AS- BUILT PLANS - OBSERVED - APPROVED.pdf FSS2019-0043 - AS- BUILT PLANS - OBSERVED - APPROVED.pdf 1 Printed: Tuesday, February 14, 2023 11:35:22 AM 6 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0043 12SRC1001514101112BOR13GPM5BEDROOM4BATH 4CASITACARTGARAGEGARAGEMECH.HALLLAUNDRYPOWDERMASTERCLOSETMASTERBATHMASTERSUITEGREATROOMKITCHENDININGFOYERBEDROOM 3BATH 3CLOSETLAUNDRYMECH.LINENCLO.TOILETROOMCLO.CLO.BATH 2HALLBEDROOM 2STR.34BREEZEWAYPATIOPATIO1HANGER LEGEND STANDARD SYMBOLS1 - U - HOOK2 - C CLAMP, ROD, & RING3 - POWDER STUD, ROD, & RING5 - EYE ROD, & RING4 - ANGLE CLIP, ROD, & RING6 - COACH SCREW, ROD, & RING7 - CONC. SHELL, ROD, & RING - CHECK VALVE - O. S. & Y. VALVE - FIRE DEPT. CONNECTION - FIRE HYDRANT - KEY VALVE - POST INDICATOR VALVE - UNDG. BY SHASTA FIRE - UNDG. BY OTHERSSTANDARD SYMBOLS - RISER WITH ALARM VALVE - RISER WITH FLOW SWITCH - WATER MOTOR GONG - ELECTRIC BELL - PIPE HANGER LOCATION - FOUR WAY SWAY BRACE - TWO WAY SWAY BRACE - HYDRAULIC NODE POINTNOZZLE MFG. DEGREE ESCUTCHEON FINISH QUANTITYCONTRACT WITHARCHITECTWATER COMPANYFIELD INSPECTIONNO. DATE:REVISIONSSCALE:PROJECT:STATE LIC. NO.(CA.) 476633 (AZ.) 101519LIC. CLASS C-16DRAWN BY:DATE:JOB NO.DRWG. NO.OFPHONE: (760) 323-5993FAX: (760) 323-8895info@shastafire.comZERBST RESIDENCEAT COYOTE CANYON COURTTRADITION GOLF CLUB, LOT 50LA QUINTA, CA 92253218-0783-28-19SHASTA FIRE PROTECTION, INC.72120 Northshore St. Suite CThousand Palms, Ca. 92276NFIRE RISER, DIAGRAMMATIC114" SCH 30 MINIMUM PIPESIZEPLAN NOTES1. SHASTA FIRE PROTECTION'S POINT OF CONNECTION TO FIRE SPRINKLERSYSTEM IS 0'-6" ABOVE FINISHED FLOOR LINE WITHIN GARAGE OFDWELLING UNIT. ALL MATERIALS, DEVICES, WORK, ETC. UPSTREAM OF THISPOINT, WILL BE BY OTHERS2. THIS PLAN DIAGRAMS THE APPROXIMATE LOCATIONS OF UNDERGROUNDPIPING SHOWN ONLY FOR REVIEW OF FIRE SPRINKLER PLAN ANDHYDRAULIC CALCULATIONS PLEASE REFER TO CIVIL DRAWING FORINSTALLATION OF UNDERGROUND PIPE AND DEVICESNOTE TO CONTRACTOR3. ANY PRESSURE REDUCING DEVICE FOR DOMESTIC WATER SERVICE MUST BEINSTALLED DOWNSTREAM OF WATER SUPPLY WHERE THE DOMESTIC AND FIRESERVICE INTERSECT. THE FIRE SPRINKLER SYSTEM HAS BEEN HYDRAULICALLYCALCULATED WITH THE FULL PRESSURE THAT IS AVAILABLE.GENERAL NOTES1. SYSTEM DESIGN WILL BE IN ACCORDANCE WITH NFPA 13D (2016 EDITION)AND PER. THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVINGJURISDICTION.2. AUTO. FIRE SPKR. SYSTEM SHALL BE DESIGNED FOR LIGHT HAZARDOCCUPANCY. MAX. SPRINKLER SPACING AT ROOF OR CEILING LEVEL,SHALL BE 400 SQ. FT. PER. HEAD. SYSTEM SHALL BE HYDRAULICALLYCALCULATED FOR .05 G.P.M. PER. SQ. FT. OVER THE MOST REMOTE TWOHEADS3. ALL HANGERS AND THEIR METHOD OF INSTALLATION, SHALL CONFORMWITH NFPA 13D (SEE PLAN FOR SPECIFIC TYPE AND LOCATION OF HANGER)4. ALL SWAY BRACING AND PROTECTION OF PIPING, SHALL CONFORM WITHNFPA 13D5. SPRINKLER HEADS TO BE LOCATED PER. CODE6. SHASTA FIRE PROTECTION INC., TAKES NO RESPONSIBILITY FORSTRUCTURAL FAILURE DUE TO WATER FILLED SPRINKLER PIPING LOADS1312VIKING RESIDENTIAL CONCEALEDPENDENT HEAD INFORMATIONK=4.9, 155o/200o, SIN#VK949MAXIMUM AREA OF COVERAGE:20' X 20' (10' TO ANY WALL)MINIMUM WATER SUPPLY REQUIREMENT:20 G.P.M. @ 16.7 P.S.I.SYSTEMSYSTEM DESIGN DATAWETHAZARD CLASSIFICATION:DATA G.P.M./SQ. FT. REQUIREMENT SQ. FT./HEAD APPLICATION ALLOWANCEOF RISERSUPPLY P.S.I. P.S.I. FLOWINGSOURCE: DATE: TIME:CVWD94.12 HEADS.055256LIGHT1/31/19DRYCALCULATEDPIPE SCHEDULEPRE-ACTIONDELUGETYPEHYD. DESIGNAREA OF HOSETOTAL SYSTEM@ BASEWATER STATIC RESIDUAL G.P.M.GPM40.78 GPM @ 39.45 PSIPAGE CONTENTS:PIPING PLANINSPECTOR'S TEST VALVEHORN AND STROBEVIKING VK-302 PENDENTINFORMATIONK=4.0, 165o, SIN#VK4800MAXIMUM AREA OF COVERAGE:16' X 18' (8'-0" TO ANY WALL)MINIMUM WATER SUPPLY REQUIREMENT:18 G.P.M. @ 20.3 P.S.I.12" BELOW FINISHED CEILINGCOYOTE COURTSOURCE1" MINIMUMWATER METER ASSEMBLYWM71.48 1525APPROXIMATE UNDERGROUNDPLAN FOR HYDRAULICREFERENCE ONLY.NOT PART OF THIS CONTRACT.(6-7)1(4-9)(9-4)1(4-5)1(5-4)1(10-0)(15-0)11(10-4)(3-7)1(9-10)111(6-7)1(3-5)1(3-11)1(8-1)1(4-8)(8-9)1(2-0)1(8-2)1(3-7)1(6-7)1(6-9)1(3-5)1111(13-3)111(1-0)111(1-1)1(8-6)(6-7)(6-7)(6-7)(6-7)(15-0)1(15-0)1(15-0)(7-2)(3-4)1(1-5)(6-3)(2-11)(7-7)(0-6)1(5-0)1(5-0)1(0-4)1(0-4)1(5-4)(6-7)(1-0)1(4-8)(2-0)1 10'-0"WPWPWPJJJJWPWPWP10'-0"10'-0"9'-0"10'-0"10'-0"10'-0"9'-0"10'-0"10'-0"19'-10"10'-0"9'-0"9'-0"10'-0"10'-0"14'-0"9'-0"10'-0"10'-0"10'-0"9'-0"10'-0"9'-0"9'-6"11'-10"SCSCSCSCSCSCSSCSSSSSSSSSS12x10 TYP, 12x10 TYP,12x10 TYP,12x10 TYP,14x18 RIDGE BEAM12x10 BEAM 12x10 BEAM12x10 BEAM12x10 BEAM12x10 BEAM 12x10 BEAM 12x10 BEAM 12x10 BEAM 12x10 BEAM 12x10 BEAM12x10 BEAM12x10 BEAM12x10 BEAM 12x10 BEAM 12x10 BEAM 12x10 BEAM BEDROOM4BATH 4CASITACARTGARAGEGARAGEMECH.HALLLAUNDRYPOWDERMASTERCLOSETMASTERBATHMASTERSUITEGREATROOMKITCHENDININGFOYERBEDROOM 3BATH 3CLOSETLAUNDRYMECH.LINENCLO.TOILETROOMCLO.CLO.BATH 2HALLBEDROOM 2STR.BREEZEWAYPATIOPATIO16'-5"16'-5"12x10 BEAM12x10 BEAM 12x10 BEAM 12x10 BEAM 12x10 BEAM12x10 BEAM12x10 BEAM12x10 BEAM12x10 BEAM12x10 BEAM2HANGER LEGENDSTANDARD SYMBOLS1 - U - HOOK2 - C CLAMP, ROD, & RING3 - POWDER STUD, ROD, & RING5 - EYE ROD, & RING4 - ANGLE CLIP, ROD, & RING6 - COACH SCREW, ROD, & RING7 - CONC. SHELL, ROD, & RING - CHECK VALVE - O. S. & Y. VALVE - FIRE DEPT. CONNECTION - FIRE HYDRANT - KEY VALVE - POST INDICATOR VALVE - UNDG. BY SHASTA FIRE - UNDG. BY OTHERSSTANDARD SYMBOLS - RISER WITH ALARM VALVE - RISER WITH FLOW SWITCH - WATER MOTOR GONG - ELECTRIC BELL - PIPE HANGER LOCATION - FOUR WAY SWAY BRACE - TWO WAY SWAY BRACE - HYDRAULIC NODE POINTNOZZLEMFG.DEGREEESCUTCHEONFINISHQUANTITYCONTRACT WITHARCHITECTWATER COMPANYFIELD INSPECTIONNO. DATE:REVISIONSSCALE:PROJECT:STATE LIC. NO.(CA.) 476633(AZ.) 101519LIC. CLASS C-16DRAWN BY:DATE:JOB NO.DRWG. NO.OFPHONE: (760) 323-5993FAX: (760) 323-8895info@shastafire.comZERBST RESIDENCEAT COYOTE CANYON COURTTRADITION GOLF CLUB, LOT 50LA QUINTA, CA 92253218-0783-28-19KEVIN G.SHASTA FIRE PROTECTION, INC.72120 Northshore St. Suite CThousand Palms, Ca. 92276NPLAN NOTES1.SHASTA FIRE PROTECTION'S POINT OF CONNECTION TO FIRE SPRINKLERSYSTEM IS 0'-6" ABOVE FINISHED FLOOR LINE WITHIN GARAGE OFDWELLING UNIT. ALL MATERIALS, DEVICES, WORK, ETC. UPSTREAM OF THISPOINT, WILL BE BY OTHERS2.THIS PLAN DIAGRAMS THE APPROXIMATE LOCATIONS OF UNDERGROUNDPIPING SHOWN ONLY FOR REVIEW OF FIRE SPRINKLER PLAN ANDHYDRAULIC CALCULATIONS PLEASE REFER TO CIVIL DRAWING FORINSTALLATION OF UNDERGROUND PIPE AND DEVICESNOTE TO CONTRACTOR3.ANY PRESSURE REDUCING DEVICE FOR DOMESTIC WATER SERVICE MUST BEINSTALLED DOWNSTREAM OF WATER SUPPLY WHERE THE DOMESTIC AND FIRESERVICE INTERSECT. THE FIRE SPRINKLER SYSTEM HAS BEEN HYDRAULICALLYCALCULATED WITH THE FULL PRESSURE THAT IS AVAILABLE.GENERAL NOTES1.SYSTEM DESIGN WILL BE IN ACCORDANCE WITH NFPA 13D (2016 EDITION)AND PER. THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVINGJURISDICTION.2.AUTO. FIRE SPKR. SYSTEM SHALL BE DESIGNED FOR LIGHT HAZARDOCCUPANCY. MAX. SPRINKLER SPACING AT ROOF OR CEILING LEVEL,SHALL BE 400 SQ. FT. PER. HEAD. SYSTEM SHALL BE HYDRAULICALLYCALCULATED FOR .05 G.P.M. PER. SQ. FT. OVER THE MOST REMOTE TWOHEADS3.ALL HANGERS AND THEIR METHOD OF INSTALLATION, SHALL CONFORMWITH NFPA 13D (SEE PLAN FOR SPECIFIC TYPE AND LOCATION OF HANGER)4.ALL SWAY BRACING AND PROTECTION OF PIPING, SHALL CONFORM WITHNFPA 13D5.SPRINKLER HEADS TO BE LOCATED PER. CODE6.SHASTA FIRE PROTECTION INC., TAKES NO RESPONSIBILITY FORSTRUCTURAL FAILURE DUE TO WATER FILLED SPRINKLER PIPING LOADSVIKING RESIDENTIAL CONCEALEDPENDENT HEAD INFORMATIONK=4.9, 155o/200o, SIN#VK949MAXIMUM AREA OF COVERAGE:20' X 20' (10' TO ANY WALL)MINIMUM WATER SUPPLY REQUIREMENT:20 G.P.M. @ 16.7 P.S.I.SYSTEMSYSTEM DESIGN DATAWETHAZARD CLASSIFICATION:DATA G.P.M./SQ. FT. REQUIREMENT SQ. FT./HEAD APPLICATIONALLOWANCEOF RISERSUPPLYP.S.I.P.S.I.FLOWINGSOURCE:DATE:TIME:CVWD94.12 HEADS.055256LIGHT1/31/19DRYCALCULATEDPIPE SCHEDULEPRE-ACTIONDELUGETYPEHYD. DESIGNAREA OFHOSETOTAL SYSTEM@ BASEWATERSTATICRESIDUALG.P.M.GPM40.78 GPM @ 39.45 PSIPAGE CONTENTS:REFLECTED CEILING PLANHORN AND STROBEVIKING VK-302 PENDENTINFORMATIONK=4.0, 165o, SIN#VK4800MAXIMUM AREA OF COVERAGE:16' X 18' (8'-0" TO ANY WALL)MINIMUM WATER SUPPLY REQUIREMENT:18 G.P.M. @ 20.3 P.S.I.12" BELOW FINISHED CEILING71.481525FIRE RISER, DIAGRAMMATIC114" SCH 30 MINIMUM PIPESIZE1312INSPECTOR'S TEST VALVE 12SRC1001514101112BOR13GPM5BEDROOM4BATH 4CASITACARTGARAGEGARAGEMECH.HALLLAUNDRYPOWDERMASTERCLOSETMASTERBATHMASTERSUITEGREATROOMKITCHENDININGFOYERBEDROOM 3BATH 3CLOSETLAUNDRYMECH.LINENCLO.TOILETROOMCLO.CLO.BATH 2HALLBEDROOM 2STR.34BREEZEWAYPATIOPATIO1HANGER LEGENDSTANDARD SYMBOLS1 - U - HOOK2 - C CLAMP, ROD, & RING3 - POWDER STUD, ROD, & RING5 - EYE ROD, & RING4 - ANGLE CLIP, ROD, & RING6 - COACH SCREW, ROD, & RING7 - CONC. SHELL, ROD, & RING - CHECK VALVE - O. S. & Y. VALVE - FIRE DEPT. CONNECTION - FIRE HYDRANT - KEY VALVE - POST INDICATOR VALVE - UNDG. BY SHASTA FIRE - UNDG. BY OTHERSSTANDARD SYMBOLS - RISER WITH ALARM VALVE - RISER WITH FLOW SWITCH - WATER MOTOR GONG - ELECTRIC BELL - PIPE HANGER LOCATION - FOUR WAY SWAY BRACE - TWO WAY SWAY BRACE - HYDRAULIC NODE POINTNOZZLEMFG.DEGREEESCUTCHEONFINISHQUANTITYCONTRACT WITHARCHITECTWATER COMPANYFIELD INSPECTIONNO. DATE:REVISIONSSCALE:PROJECT:STATE LIC. NO.(CA.) 476633(AZ.) 101519LIC. CLASS C-16DRAWN BY:DATE:JOB NO.DRWG. NO.OFPHONE: (760) 323-5993FAX: (760) 323-8895info@shastafire.comZERBST RESIDENCEAT COYOTE CANYON COURTTRADITION GOLF CLUB, LOT 50LA QUINTA, CA 92253218-0783-28-19KEVIN G.SHASTA FIRE PROTECTION, INC.72120 Northshore St. Suite CThousand Palms, Ca. 92276NFIRE RISER, DIAGRAMMATIC114" SCH 30 MINIMUM PIPESIZEPLAN NOTES1.SHASTA FIRE PROTECTION'S POINT OF CONNECTION TO FIRE SPRINKLERSYSTEM IS 0'-6" ABOVE FINISHED FLOOR LINE WITHIN GARAGE OFDWELLING UNIT. ALL MATERIALS, DEVICES, WORK, ETC. UPSTREAM OF THISPOINT, WILL BE BY OTHERS2.THIS PLAN DIAGRAMS THE APPROXIMATE LOCATIONS OF UNDERGROUNDPIPING SHOWN ONLY FOR REVIEW OF FIRE SPRINKLER PLAN ANDHYDRAULIC CALCULATIONS PLEASE REFER TO CIVIL DRAWING FORINSTALLATION OF UNDERGROUND PIPE AND DEVICESNOTE TO CONTRACTOR3.ANY PRESSURE REDUCING DEVICE FOR DOMESTIC WATER SERVICE MUST BEINSTALLED DOWNSTREAM OF WATER SUPPLY WHERE THE DOMESTIC AND FIRESERVICE INTERSECT. THE FIRE SPRINKLER SYSTEM HAS BEEN HYDRAULICALLYCALCULATED WITH THE FULL PRESSURE THAT IS AVAILABLE.GENERAL NOTES1.SYSTEM DESIGN WILL BE IN ACCORDANCE WITH NFPA 13D (2016 EDITION)AND PER. THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVINGJURISDICTION.2.AUTO. FIRE SPKR. SYSTEM SHALL BE DESIGNED FOR LIGHT HAZARDOCCUPANCY. MAX. SPRINKLER SPACING AT ROOF OR CEILING LEVEL,SHALL BE 400 SQ. FT. PER. HEAD. SYSTEM SHALL BE HYDRAULICALLYCALCULATED FOR .05 G.P.M. PER. SQ. FT. OVER THE MOST REMOTE TWOHEADS3.ALL HANGERS AND THEIR METHOD OF INSTALLATION, SHALL CONFORMWITH NFPA 13D (SEE PLAN FOR SPECIFIC TYPE AND LOCATION OF HANGER)4.ALL SWAY BRACING AND PROTECTION OF PIPING, SHALL CONFORM WITHNFPA 13D5.SPRINKLER HEADS TO BE LOCATED PER. CODE6.SHASTA FIRE PROTECTION INC., TAKES NO RESPONSIBILITY FORSTRUCTURAL FAILURE DUE TO WATER FILLED SPRINKLER PIPING LOADS1312VIKING RESIDENTIAL CONCEALEDPENDENT HEAD INFORMATIONK=4.9, 155o/200o, SIN#VK949MAXIMUM AREA OF COVERAGE:20' X 20' (10' TO ANY WALL)MINIMUM WATER SUPPLY REQUIREMENT:20 G.P.M. @ 16.7 P.S.I.SYSTEMSYSTEM DESIGN DATAWETHAZARD CLASSIFICATION:DATA G.P.M./SQ. FT. REQUIREMENT SQ. FT./HEAD APPLICATIONALLOWANCEOF RISERSUPPLYP.S.I.P.S.I.FLOWINGSOURCE:DATE:TIME:CVWD94.12 HEADS.055256LIGHT1/31/19DRYCALCULATEDPIPE SCHEDULEPRE-ACTIONDELUGETYPEHYD. DESIGNAREA OFHOSETOTAL SYSTEM@ BASEWATERSTATICRESIDUALG.P.M.GPM40.78 GPM @ 39.45 PSIPAGE CONTENTS:PIPING PLANINSPECTOR'S TEST VALVEHORN AND STROBEVIKING VK-302 PENDENTINFORMATIONK=4.0, 165o, SIN#VK4800MAXIMUM AREA OF COVERAGE:16' X 18' (8'-0" TO ANY WALL)MINIMUM WATER SUPPLY REQUIREMENT:18 G.P.M. @ 20.3 P.S.I.12" BELOW FINISHED CEILINGCOYOTE COURTSOURCE1" MINIMUMWATER METER ASSEMBLYWM71.481525APPROXIMATE UNDERGROUNDPLAN FOR HYDRAULICREFERENCE ONLY.NOT PART OF THIS CONTRACT.1¼(5-1½)1¼(6-7)1(4-9)1¼(9-4)1(1-7½)1¼(4-5)1(5-4)1(10-0)1¼(9-5½)1¼(15-0)1¼ (11-4½)1(6-10½)1(10-4)1¼(3-7)1(0-9½)1¼(9-10)1(12-6½)1(5-4½)1(6-5½)1¼(0-5½)1¼(6-7)1¼(7-7½)1¼(1-6½) 1 (3-5) 1 (3-11) 1¼(3-11½)1(8-1)1(4-8)1¼(8-9)1¼ (12-4½) 1 (2-0) 1 (8-2)1(3-7)1¼(6-2½)1¼ (1-4½)1¼(11-5½)1¼(8-3½)1 (2-7½)1¼(8-4½)1¼(6-7)1¼(10-0½)1¼ (4-11½) 1 (6-9)1(3-5)1¼(4-5½)1 (4-9½) 1 (4-9½) 1 (8-0½)1(13-3)1(11-1½)1(10-3½)1(1-0)1 (3-3½)1 (2-3½) 1 (4-11½)1¼(1-1)1¼(5-4½)1(8-6)1¼(4-11½)1¼(6-7)1¼(6-7)1¼(6-7)1¼(6-7)1¼(15-0)1(15-0)1 (15-0) 1¼ (7-2) 1¼ (3-4)1(1-5)1¼(5-4½)1¼ (6-3)1¼(2-11)1¼(7-7)1¼ (0-6)1(5-0)1(5-0)1 (0-4) 1 (0-4)1(5-4)1¼(5-1½)1¼(6-1½)1¼(3-2½)1¼(6-2½)1¼(6-7)1¼(6-1½)1¼(3-2½) 1¼ (1-0) 1¼ (6-8½)1(4-8)1¼(1-1½)1¼(2-9½) 1¼ (2-0)1(4-6½) 10'-0"WPWPWPJJJJWPWPWP10'-0"10'-0"9'-0"10'-0"10'-0"10'-0"9'-0"10'-0"10'-0"19'-10"10'-0"9'-0"9'-0"10'-0"10'-0"14'-0"9'-0"10'-0"10'-0"10'-0"9'-0"10'-0"9'-0"9'-6"11'-10"SCSCSCSCSCSCSSCSSSSSSSSSS12x10 TYP, 12x10 TYP,12x10 TYP,12x10 TYP,14x18 RIDGE BEAM12x10 BEAM 12x10 BEAM12x10 BEAM12x10 BEAM12x10 BEAM 12x10 BEAM 12x10 BEAM 12x10 BEAM 12x10 BEAM 12x10 BEAM12x10 BEAM12x10 BEAM12x10 BEAM 12x10 BEAM 12x10 BEAM 12x10 BEAM BEDROOM4BATH 4CASITACARTGARAGEGARAGEMECH.HALLLAUNDRYPOWDERMASTERCLOSETMASTERBATHMASTERSUITEGREATROOMKITCHENDININGFOYERBEDROOM 3BATH 3CLOSETLAUNDRYMECH.LINENCLO.TOILETROOMCLO.CLO.BATH 2HALLBEDROOM 2STR.BREEZEWAYPATIOPATIO16'-5"16'-5"12x10 BEAM12x10 BEAM 12x10 BEAM 12x10 BEAM 12x10 BEAM12x10 BEAM12x10 BEAM12x10 BEAM12x10 BEAM12x10 BEAM2HANGER LEGENDSTANDARD SYMBOLS1 - U - HOOK2 - C CLAMP, ROD, & RING3 - POWDER STUD, ROD, & RING5 - EYE ROD, & RING4 - ANGLE CLIP, ROD, & RING6 - COACH SCREW, ROD, & RING7 - CONC. SHELL, ROD, & RING - CHECK VALVE - O. S. & Y. VALVE - FIRE DEPT. CONNECTION - FIRE HYDRANT - KEY VALVE - POST INDICATOR VALVE - UNDG. BY SHASTA FIRE - UNDG. BY OTHERSSTANDARD SYMBOLS - RISER WITH ALARM VALVE - RISER WITH FLOW SWITCH - WATER MOTOR GONG - ELECTRIC BELL - PIPE HANGER LOCATION - FOUR WAY SWAY BRACE - TWO WAY SWAY BRACE - HYDRAULIC NODE POINTNOZZLEMFG.DEGREEESCUTCHEONFINISHQUANTITYCONTRACT WITHARCHITECTWATER COMPANYFIELD INSPECTIONNO. DATE:REVISIONSSCALE:PROJECT:STATE LIC. NO.(CA.) 476633(AZ.) 101519LIC. CLASS C-16DRAWN BY:DATE:JOB NO.DRWG. NO.OFPHONE: (760) 323-5993FAX: (760) 323-8895info@shastafire.comZERBST RESIDENCEAT COYOTE CANYON COURTTRADITION GOLF CLUB, LOT 50LA QUINTA, CA 92253218-0783-28-19KEVIN G.SHASTA FIRE PROTECTION, INC.72120 Northshore St. Suite CThousand Palms, Ca. 92276NPLAN NOTES1.SHASTA FIRE PROTECTION'S POINT OF CONNECTION TO FIRE SPRINKLERSYSTEM IS 0'-6" ABOVE FINISHED FLOOR LINE WITHIN GARAGE OFDWELLING UNIT. ALL MATERIALS, DEVICES, WORK, ETC. UPSTREAM OF THISPOINT, WILL BE BY OTHERS2.THIS PLAN DIAGRAMS THE APPROXIMATE LOCATIONS OF UNDERGROUNDPIPING SHOWN ONLY FOR REVIEW OF FIRE SPRINKLER PLAN ANDHYDRAULIC CALCULATIONS PLEASE REFER TO CIVIL DRAWING FORINSTALLATION OF UNDERGROUND PIPE AND DEVICESNOTE TO CONTRACTOR3.ANY PRESSURE REDUCING DEVICE FOR DOMESTIC WATER SERVICE MUST BEINSTALLED DOWNSTREAM OF WATER SUPPLY WHERE THE DOMESTIC AND FIRESERVICE INTERSECT. THE FIRE SPRINKLER SYSTEM HAS BEEN HYDRAULICALLYCALCULATED WITH THE FULL PRESSURE THAT IS AVAILABLE.GENERAL NOTES1.SYSTEM DESIGN WILL BE IN ACCORDANCE WITH NFPA 13D (2016 EDITION)AND PER. THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVINGJURISDICTION.2.AUTO. FIRE SPKR. SYSTEM SHALL BE DESIGNED FOR LIGHT HAZARDOCCUPANCY. MAX. SPRINKLER SPACING AT ROOF OR CEILING LEVEL,SHALL BE 400 SQ. FT. PER. HEAD. SYSTEM SHALL BE HYDRAULICALLYCALCULATED FOR .05 G.P.M. PER. SQ. FT. OVER THE MOST REMOTE TWOHEADS3.ALL HANGERS AND THEIR METHOD OF INSTALLATION, SHALL CONFORMWITH NFPA 13D (SEE PLAN FOR SPECIFIC TYPE AND LOCATION OF HANGER)4.ALL SWAY BRACING AND PROTECTION OF PIPING, SHALL CONFORM WITHNFPA 13D5.SPRINKLER HEADS TO BE LOCATED PER. CODE6.SHASTA FIRE PROTECTION INC., TAKES NO RESPONSIBILITY FORSTRUCTURAL FAILURE DUE TO WATER FILLED SPRINKLER PIPING LOADSVIKING RESIDENTIAL CONCEALEDPENDENT HEAD INFORMATIONK=4.9, 155o/200o, SIN#VK949MAXIMUM AREA OF COVERAGE:20' X 20' (10' TO ANY WALL)MINIMUM WATER SUPPLY REQUIREMENT:20 G.P.M. @ 16.7 P.S.I.SYSTEMSYSTEM DESIGN DATAWETHAZARD CLASSIFICATION:DATA G.P.M./SQ. FT. REQUIREMENT SQ. FT./HEAD APPLICATIONALLOWANCEOF RISERSUPPLYP.S.I.P.S.I.FLOWINGSOURCE:DATE:TIME:CVWD94.12 HEADS.055256LIGHT1/31/19DRYCALCULATEDPIPE SCHEDULEPRE-ACTIONDELUGETYPEHYD. DESIGNAREA OFHOSETOTAL SYSTEM@ BASEWATERSTATICRESIDUALG.P.M.GPM40.78 GPM @ 39.45 PSIPAGE CONTENTS:REFLECTED CEILING PLANHORN AND STROBEVIKING VK-302 PENDENTINFORMATIONK=4.0, 165o, SIN#VK4800MAXIMUM AREA OF COVERAGE:16' X 18' (8'-0" TO ANY WALL)MINIMUM WATER SUPPLY REQUIREMENT:18 G.P.M. @ 20.3 P.S.I.12" BELOW FINISHED CEILING71.481525FIRE RISER, DIAGRAMMATIC114" SCH 30 MINIMUM PIPESIZE1312INSPECTOR'S TEST VALVE FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 1 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATASpecifications:Minimum Operating Pressure: Refer to the Approval Chart.Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar).Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*)Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards:Sprinkler Body: Brass UNS-C84400 or QM BrassDeflector: Phosphor Bronze UNS-C51000Deflector Pins: Stainless Steel UNS-S30200Button: Brass UNS-C36000Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400Compression Screw: 18-8 Stainless SteelYoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-C51000Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE TapeCover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc PlatingShipping Cap: Polyethylene Cover Plate Materials:Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400Spring: Beryllium NickelSolder: EutecticOrdering Information: (Also refer to the current Viking price list.)Viking Freedom® Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately:Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JNTemperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = EFor example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE.Standard Cover Plates: Base Part No. 13504 (2-3/4” diameter), Base Part No. 13642 (3-5/16” diameter), or Base Part No. 15394 (square cover plate, 3-5/16”) Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4” diameter) or Base Part No. 21875 (3-5/16” diameter). Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 2 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number:Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/BTemperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.)Sprinkler Wrenches**:A. Heavy Duty Part No. 14047W/B** (available since 2006), orB. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007)D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. . Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres-sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Temperature Rating of the Cover Assembly (Required)3 Cover Plate Base Part Number4 Large Cover Plate Base Part Number4 Square Cover Plate Base Part Number4 Bulb Color Ordinary 155 °F (68 °C)100 °F (38 °C)135 °F (57 °C)13504 or 218766 13642 or 218756 15394 Red Intermediate 200 °F (93 °C)150 °F (65 °C)135 °F (57 °C)13504 or 218766 13642 or 218756 15394 Green Sprinkler Finishes: Brass and ENT Cover Plate Finishes6: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings5: ENT Footnotes 1. The sprinkler temperature rating is stamped on the deflector. 2. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 6. Stainless Steel versions are not available with any finishes or paint. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 3 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 Approval ChartViking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D S p r i n k l e r B a s e Part Number 1 SIN NPT Thread Size Nominal K-Factor Maximum Water Wor- king PressureInchesmmU.S.metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage Area 6 W X L Ft. X Ft. (m X m) Flow GPM (LPM) Pressure PSI (bar)Deflector to Ceiling Installation Type Listings and Approvals3,5 Minimum Spacing Ft. (m)155 °F (68 °C), 200 °F (93 °C) Temperature Rated Sprinklers 4 12 X 12 (3.7 X 3.7) 13 (49.2) 7.0 (0.48) Refer to Figure 2 Concealed with Cover Plate Assembly. See Footnote 8. See Footnotes 7,9, 10, & 11 8 (2.4) 14 X 14 (4.3 X 4.3) 13 (49.2) 7.0 (0.48) 16 X 16 (4.9 X 4.9) 13 (49.2) 7.0 (0.48) 18 X 18 (5.5 X 5.5) 17 (64.4) 12.0 (0.83) 20 X 20 (6.1 X 6.1) 20 (75.7) 16.7 (1.15) Footnotes 1. Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4. Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. Meets New York City requirements, effective July 1, 2008. 6. For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 7. Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). 8. Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 9. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 8. 10. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) 11. Stainless Steel Cover plate temperature rating is 135 °F (57 °C). Stainless Steel Cover Part Numbers: 218761 and 218751 (large diameter). FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 4 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover-age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in-stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047W/B** ** A 1/2” ratchet is required (Not available from Viking) 2-1/4” (57 mm) diameter opening required in the ceiling. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 1: Sprinkler Installation and Proper Wrench Usage NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 5 of 5 Form No. F_012116 18.10.11 Rev 18.1.P65 Figure 2: Sprinkler Dimensions and Cover Installation 1/2” (15 mm) NPT 2-1/4”(58 mm)2-9/16” (65 mm)Maximum 2-1/16” (52 mm)Minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. Figure 3: Identification of Custom Paint for Concealed Covers All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label.FACTORY APPLIE D C USTO M P AI NT COLORFigure 4: Square Cover Assembly 15394 3-5/16” (84 mm) Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) FREEDOM® RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK4800 TECHNICAL DATA Form No. F_100810 18.11.01 Rev 17.1.P65 Page 1 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. 1. DESCRIPTION Viking Freedom® Residential Concealed Horizontal Sidewall Lead Free1 Sprinkler VK4800 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on concealed pipe systems, where the appearance of a smooth wall is desired. The orifice design, with a K-Factor of 4.0 (57.7 metric2), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is hidden from view by a low profile, small diameter cover plate installed flush to the wall. The cover plate is available in several decorative finishes to meet design requirements. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. After the system has been tested and wall finish has been applied, the push-on design of the cover plate assembly allows easy installation of the cover plate with up to 1/4” (6.4 mm) adjustment. Sprinkler VK4800 is provided with a pipe guide to properly locate the sprinkler and allow the 1/4” adjustment of the cover plate. 1 Lead content complies with the definition of ‘Lead Free’ established in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA’s Water Utility Council, and California Assembly Bill #1953. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW (VK4800) UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components and NSF 372 (MH48034). Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2010. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.0 U.S. (57.7 metric*) 2 Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Available Cover Plate Horizontal Adjustment: 1/4” (6 mm) Overall Length (Sprinkler Body): 2” (50 mm) Covered by the following US Patent Numbers: 7,712,218 and 8,960,319 Material Standards: Sprinkler Body: Brass UNS-C89833 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Seat: Brass UNS-C64200 Deflector Ring: Brass UNS-C23000 Deflector Pins: Stainless Steel UNS-S30200 Halo: Phoshpor Bronze UNS-C51000 Flow Shaper: Phosphor Bronze UNS-C51000 Lever Bar Ring: Brass UNS-C84400 Compression Screw: 18-8 Stainless Steel Fusible Link Assembly: Nickel Alloy and Eutectic Solder Fusible Link Levers: Stainless Steel UNS-S31600 Guide Pin: Stainless Steel UNS-S43000 Shipping Cap: Polyethylene Replaces Form No. F_100810 Rev 17.1 (Added P65 Warning.) FREEDOM® RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK4800 TECHNICAL DATA Form No. F_100810 18.11.01 Rev 17.1.P65 Page 2 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Cover Assembly Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom® Residential Concealed HSW Sprinkler VK4800 and Cover Plate Assembly must be ordered separately: Sprinkler: Base part No. 16880A Temperature Suffixes: 165 °F (74 °C) = C, 205 °F (96 °C) = E For example, sprinkler VK4800 with a Brass finish and a 165 °F (74 °C) temperature rating = Part No. 16880AC Cover Plate Assembly: Base Part No. 16207 (3-5/16” diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: White Polyester = M-/W Temperature Suffix: 135 °F (57 °C) = A For example, cover 16207 with a White Painted finish and a 135 °F (57 °C) temperature rating = 16207MA/W. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 16208W/R (available since 2010) B. Head Cabinet Wrench Part Number 16267*** (available since 2010) C. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: five (5) sprinklers (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the fusible element to disengage, releasing the sealing assembly. Water flowing through the sprinkler orifice strikes the flow shaper, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Freedom® Residential Concealed Horizontal Sidewall Sprinkler VK4800 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. FREEDOM® RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK4800 TECHNICAL DATA Form No. F_100810 18.11.01 Rev 17.1.P65 Page 3 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Temperature Rating of the Cover Assembly (Required) Cover Plate Base Part Number3 Ordinary 165 °F (74 °C)100 °F (38 °C)135 °F (57 °C)16207 Intermediate 205 °F (96 °C)150 °F (65 °C)4 135 °F (57 °C)16207 Cover Plate Finish: White Polyester Footnotes 1 The sprinkler temperature rating is stamped on the inlet. 2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 4 Cover plate is ONLY 135 °F (57 °C). Approval ChartViking VK4800, 4.0 K-Factor Residential Concealed HSW Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria on page 4. For Ceiling types refer to the most current Edition of NFPA 13, 13R or 13D. Sprinkler Base Part Number 1 SIN NPT Thread Size Nominal K-Factor Maximum Water Working PressureInchesmmU.S.metric 2 16880A VK4800 1/2 15 4.0 57.7 175 psi (12 bar) Max. Coverage Area 6 Width X Length Ft. X Ft. (m X m) Max. Spacing Ft. (m) Ordinary Temp Rating (165 °F/74 °C) Intermediate Temp Rating (205 °F/96 °C)Centerline of Sprinkler to Ceiling Installation Type Listings and Approvals3 Minimum Spacing Ft. (m) Flow 6 GPM (L/min) Pressure 6 PSI (bar) Flow 6 GPM (L/min) Pressure 6 PSI (bar) 4 NYC NSF 12 X 12 (3.7 X 3.7)12 (3.7)11 (41.7)7.6 (0.52)13 (49.3)10.6 (0.73) 4-3/8 to 6-3/8 inches Concealed with Cover Plate AssemblySee Footnote 8 and 9See Footnote 5--8 (2.4) 14 X 14 (4.3 X 4.3)14 (4.3)13 (49.3)10.6 (0.73)13 (49.3)10.6 (0.73) 16 X 16 (4.9 X 4.9)16 (4.9)16 (60.6)16 (1.10)16 (60.6)16 (1.10) 16 X 18 (4.9 X 5.5)16 (4.9)17 (64.4)18.1 (1.25)18 (68.1)20.3 (1.40) 12 X 12 (3.7 X 3.7)12 (3.7)12 (45.5)9 (0.62)13 (49.3)10.6 (0.73) 6-3/8 to 12- 3/8 inches 14 X 14 (4.3 X 4.3)14 (4.3)14 (53.0)12.3 (0.84)14 (53.0)12.3 (0.84) 16 X 16 (4.9 X 4.9)16 (4.9)16 (60.6)16 (1.10)16 (60.6)16 (1.10) 16 X 18 (4.9 X 5.5)16 (4.9)18 (68.1)20.3 (1.40)18 (68.1)20.3 (1.40) Footnotes 1 For complete part number, also refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria listed below. 4 Sprinkler VK4800 is Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5 Meets New York City requirements, effective July 1, 2008. 6 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 7 Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. 8 Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 162071. 9 Accepted Cover Plate Finishes are: White Polyester7. 10 cULus Listed as corrosion resistant. FREEDOM® RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK4800 TECHNICAL DATA Form No. F_100810 18.11.01 Rev 17.1.P65 Page 4 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. DESIGN CRITERIA (Also refer to the Approval Chart above.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Horizontal Sidewall Lead Free Sprinkler VK4800 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart above. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart above for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • THE TOP OF THE SPRINKLER BODY AND THE TOP OF THE INSTALLATION WRENCH ARE MARKED “TOP”. Orient the top of the sprinkler element parallel with the ceiling as shown in Figure 3. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080190 and Form No. F_080415 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label.FACTORY APPLIE D C USTO M P AI NT COLORFigure 1: Identification of Custom Paint for Concealed Covers Figure 2: Sprinkler VK4800 Installation and Correct Use of Wrench The internal design of the sprinkler wrench is shaped to fit over the sprinkler and protective cap to ensure that the top of the wrench will be oriented in the same direction as the top of the sprinkler deflector. Sprinkler bodySprinkler wrench Orient the sprinkler and wrench as shown then slide the wrench over the sprinkler body and the protective cap. FREEDOM® RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK4800 TECHNICAL DATA Form No. F_100810 18.11.01 Rev 17.1.P65 Page 5 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Figure 4: Sprinkler VK4800 Dimensions and Cover Installation ** A 1/2” ratchet is required (not available from Viking). Figure 3: Sprinkler VK4800 Correct Deflector Orientation Keep the top of the element oriented parallel to the ceiling. CEILING Measure from the centerline of the sprinkler to the ceiling. 1/2” (15 mm) NPT 2-3/16” (56 mm) diameter opening required in the wall. Concealed Sprinkler Wrench** 16208W/R To install the Cover Plate assembly, gently push it onto the sprinkler body with even pressure using the palm of the hand. 1/4” (6 mm) Horizontal adjustment available. Concealed sprinkler body with protective cap 2-3/16” (56 mm) Maximum 1-15/16” (49 mm) Minimum The top of the sprinkler is marked “TOP”. Centerline of sprinkler (Corresponds with the centerline of the wrench) *Distance from the ceiling affects water supply requirements. Refer to the Approval Chart. Refer to the Approval Chart for minimum and maximum allowable distance from the centerline of the sprinkler to the ceiling*. 3-5/16” (84 mm) 1/4” (6 mm) FREEDOM® RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK4800 TECHNICAL DATA Form No. F_100810 18.11.01 Rev 17.1.P65 Page 6 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Figure 5: Sprinkler VK4800 Pipe Guide Figure 6: Sprinkler VK4800 Pipe Guide Installation Instructions 2 X 4 2 X 4 2 X 4 3/4” (20 mm) CPVC Piping 3/4” (20 mm) Pipe Guide Residential Concealed HSW Sprinkler VK4800 6” (152 mm) Max. from centerline of sprinkler to centerline of pipe guide for proper cover plate installation. 3/4” (20 mm) Pipe Guide (Hardware included) 3/4” (20 mm) Pipe Guide NOTE: To ensure that the sprinkler is located the correct distance from the face of the finished wall, use the pipe guide (included with sprinkler VK490) and attached it to the 3/4” CPVC pipe and the 2 X 4 inside the wall as shown. All piping, hangers/bracing must be installed in accordance with NFPA 13. 2-1/8” (52 mm) 2-3/4” (70 mm) 1” (25 mm) 2 X 4 2 X 4(Plan View) FREEDOM® RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK4800 TECHNICAL DATA Form No. F_100810 18.11.01 Rev 17.1.P65 Page 7 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Figure 7: Sprinkler VK4800 Installation - Soffit Refer to the Approval Chart for minimum and maximum allowable distance from the centerline of the sprinkler to the ceiling.* 2-3/16” (56 mm) 2-3/16” (56 mm) Maximum 1-15/16” (49 mm) Minimum 8” Maximum (203 mm) (NFPA 13, NFPA 13R, & NFPA 13D 12” Maximum (305 mm) Directly above cabinets (NFPA 13R & NFPA 13D *Distance from the ceiling affects water supply requirements. Refer to the Approval Chart Replaces Form No. F_100810 Rev 17.1 (Added P65 Warning.) TOLCO™Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap Size Range:3/4" (20mm)thru 3" (80mm)CPVC pipe Material:Pre-Galvanized Steel Function:Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Fig. 23 can be installed on the top, bottom or side of a beam. Approvals:Underwriters Laboratories Listed in the USA (UL) and Canada (cUL)sizes 3/4" (20mm)thru 2" (50mm)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.9mm)steel using (2) 1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features:Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish:Pre-Galvanized Order By:Part number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. A C B B CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 23-3/4 3/4"(20)31/8"(79.4)19/16"(39.7)13/16"(30.2)51/2 (1.67)5/16"(7.9)9 (4.1) 23-1 1"(25)33/8"(85.7)111/16"(42.9)13/16"(30.2)6 (1,83)5/16"(7.9)9 (4.1) 23-11/4 11/4"(32)43/16"(106.4)23/32"(53.1)13/16"(30.2)61/2 (1.98)5/16"(7.9)11 (5.0) 23-11/2 11/2"(40)47/16"(112.7)27/32"(56.3)13/16"(30.2)7 (2.13)5/16"(7.9)12 (5.4) 23-2 2"(50)47/8"(123.8)27/16"(61.9)13/16"(30.2)8 (2.44)5/16"(7.9)15 (6.8) 23-21/2 21/2"(65)53/8"(136.5)211/16"(68.3)13/16"(30.2)Consult Factory 5/16"(7.9)22 (10.0) 23-3 3"(80)6"(152.4)3"(76.2)13/16"(30.2)Consult Factory 5/16"(7.9)25 (11.3)Pipe Clamps Pipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 97 B-Line series Pipe Hangers & SupportsEaton Trusted above all ™ Features • Sizes Available (Nominal): 3/4” (DN20) through 3” (DN80) pipe diameters, with a Standard Dimension Ratio (SDR) of 13.5 as specified in ASTM F442. • Environmental Specifications: Indoor use only. Maximum Ambient Temperature: 150°F (65°C) • Hazen-Williams C Value: 150 • Pressure Data: Working Pressure: 175 PSI (12.1 bar) at 150°F (65°C) • Specifications: • Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Pipe meets or exceeds ASTM F442. • Certified by NSF International for potable water services. • CPVC pipe from Viking Plastics use compound cell class 23547 (demonstrated highest structural properties). • cULus Listed, FM Approved, New York City (MEA) Approved, LPCB Approved. CPVC PIPE PHYSICAL DATA Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *Weight per 15’ (4,6 m) length Length Approvals Part Number Inch DN Inch mm Inch mm Lb.Kg.Feet M 3/4”DN20 1.050 26,670 0.874 22,199 2.52 1,14 15 4.6 cULus, FM, NSF 34PIPE 1”DN25 1.315 33,401 1.101 27,965 3.93 1,78 15 4.6 1PIPE 1 1/4”DN32 1.660 42,164 1.394 35,408 6.27 2,84 15 4.6 114PIPE 1 1/2”DN40 1.900 48,260 1.598 40,589 8.22 3,73 15 4.6 112PIPE 2”DN50 2.375 60,325 2.003 50,876 12.89 5,85 15 4.6 2PIPE 2 1/2”DN65 2.875 73,000 2.423 61,500 18.86 8,55 15 4.6 212PIPE 3”DN80 3.500 88,900 2.950 74,900 28.01 12,71 15 4.6 3PIPE Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *Weight per 10’ (3,05 m) length Length Approvals Part Number Inch DN Inch mm Inch mm Lb.Kg.Feet M 3/4”DN20 1.050 26,670 0.874 22,199 1.68 0,76 10 3,05 cULus, FM, NSF 34PIPE10 1”DN25 1.315 33,401 1.101 27,965 2.62 1,19 10 3,05 1PIPE10 1 1/4”DN32 1.660 42,164 1.394 35,408 4.18 1,90 10 3,05 114PIPE10 1 1/2”DN40 1.900 48,260 1.598 40,589 5.48 2,49 10 3,05 112PIPE10 2”DN50 2.375 60,325 2.003 50,876 8.59 3,90 10 3,05 2PIPE10 2 1/2”DN65 2.875 73,000 2.423 61,500 12.57 5,70 10 3,05 212PIPE10 3”DN80 3.500 88,900 2.950 74,900 18.67 8,47 10 3,05 3PIPE10 NOTE: CPVC Pipe is produced in SDR 13.5 Dimensions in accordance with ASTM F442. Standard Dimension Ratio is the ratio of the outside pipe diameter to the wall thickness of the pipe. Blazemaster® is a registered trademark of Lubrizol. Specifications subject to change without notice *Empty pipe weights IMPORTANT: Installers should receive thorough hands-on training in the proper methods of assembly and installation of CPVC products. Trusted above all ™ CPVC Pipe Product Specifications Corrosion resistant CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturer’s design and instal- lation instructions, is UL and c-UL Listed by Underwriters Laboratories for use in the following: • Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Residential occupancies up to and including four stories in height as defined by NFPA 13R. • Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPA 13D. • Installation of private fire service mains and their appurtenances, NFPA 24. CPVC fire sprinkler pipe from Viking Plastics shall be employed in wet pipe systems only and are not listed for outdoor use. CPVC pipe must never be used in a system using compressed air or other gases. CPVC pipe from Viking Plastics also carries the following enhanced listings and approvals: • According to UL Listing • Can be flush at return air plenums • Exposed system risers NFPA 13D, 13R • Exposed basement NFPA 13D (solid wood joist) • Extended coverage (exposed) y 20’ spacing on pendent in lieu of 15’ y 18’ spacing on sidewall in lieu of 14’ • Use with combustible concealed sprinklers • UL Listed attic sprinkler head (to protect the floor below) • UL Listed attic sprinkler head with wet system piping (feed main and ridge installation) • Exposed sidewall sprinkler listing for exposed pipe & fittings y 24’ extended coverage sidewall sprinkler, 12” drop, 155°F sprinkler head y 18’ extended coverage sidewall sprinkler, 12” drop, 165°F sprinkler head y 16’ extended coverage sidewall sprinkler, 12” drop, 175°F sprinkler head y 14’ standard coverage sidewall sprinkler, 12” drop, 200°F sprinkler head • Factory Mutual Approved* • Factory Mutual Approval exposed • Factory Mutual Approval above drop-in ceilings • Factory Mutual Approval exposed w/Soffi-Steel soffiting covering system New and enhanced listings and approvals are being pursued. Always check with the appropriate Listing and Approval agency for details on current listing parameters. CPVC pipe meets all applicable standards for pressure rated applica- tion as required in ANSI-NSF Standard 14 and complies with ANSI-NSF Standard 61 for health effects and are marked with the NSF-pw end use marking. All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, and shall carry a rated working pressure of 175 psi @ 150°F (12 bar @ 65.5°C). *The FM Approval is limited to use in wet pipe fire protection sprinkler systems for light hazard occupancies in both concealed and exposed applications with certain restrictions. Piping must always be installed in strict accordance to the manufacturer’s DESIGN AND INSTALLATION GUIDE, including product storage and handling, joining methods, supporting and bracing, expansion and con- traction allowance and testing, etc. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the installation instructions. All CPVC fire sprinkler pipe from Viking Plastics is manufactured in the USA. All CPVC pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufacturing site, until shipped from the factory. The pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Foun- dation (NSF) seal of approval for potable water applications. CPVC products are intended for use in areas where the maximum ambi- ent temperature does not exceed 150°F (65.5°C). If the ambient tempera- ture is expected to exceed this limitation, refer to the manufacturer’s DE- SIGN AND INSTALLATION GUIDE for additional information on methods to reduce the pipe exposure temperatures. CPVC pipe is not intended to be installed in outdoor applications. CPVC pipe is intended to be used in wet pipe systems only and have not been investigated for use in dry pipe systems. Special installation and design criteria relative to pipe hanger spacings, piping and sprinkler restraint, sprinkler temperature rating, piping locations, testing procedures and friction loss characteristics are specified in the manufacturer’s installation instructions provided with the pipe. The manufacturer’s installation instructions should be reviewed and the Authority Having Jurisdiction consulted before installation. PF-6.13 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: MALLEABLE IRON FITTINGS Class 150 (Standard) Note: See following page for pressure-temperature ratings. Galvanized weights may vary. Please contact your Anvil Representative if you need verification. All Elbows & Tees 3/8" (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) FIGURE 1101 90˚ Elbow Size A Unit Weight Black Galv. NPS DN in mm lbs kg lbs kg 1/8 6 11/16 17 0.06 0.03 0.06 0.03 1/4 8 13/16 22 0.11 0.05 0.11 0.05 3/8 10 15/16 24 0.17 0.08 0.17 0.08 1/2 15 11/8 29 0.30 0.14 0.30 0.14 3/4 20 15/16 33 0.45 0.20 0.45 0.20 1 25 11/2 38 0.73 0.33 0.73 0.33 11/4 32 13/4 44 0.97 0.44 0.97 0.44 11/2 40 115/16 49 1.30 0.59 1.30 0.59 2 50 21/4 57 2.06 0.93 2.06 0.93 21/2 65 211/16 68 3.55 1.61 3.55 1.61 3 80 31/16 78 5.46 2.48 5.46 2.48 31/2 90 37/16 87 7.10 3.22 7.10 3.22 4 100 313/16 98 8.95 4.06 8.95 4.06 5 125 41/2 114 13.90 6.30 13.90 6.30 6 150 51/8 130 23.00 10.43 23.00 10.43 A A q MALLEABLE IRON FITTINGS PF-11.16 Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME B16.39. ALL ELBOWS & TEES 3⁄8" (10 DN) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 Sizes 1⁄4"–1" (6–25 mm) Sizes 11⁄4"–2" (32–51 mm) Sizes 21⁄2"–3" (64–76 mm) (°F)(°C)psi bar psi bar psi bar psi bar -20° to 150° -28.9° to 65.6° 300 20.7 2,000 137.9 1,500 103.4 1,000 68.9 200°93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 250°121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 300°148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 350°176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 400°204.4 ––935 64.5 750 51.7 560 38.6 450°232.2 ––725 50.0 600 41.4 475 32.8 500°260.0 ––510 35.2 450 31.0 385 26.5 550°287.8 ––300 20.7 300 20.7 300 20.7 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil Sales Representative. Standards and Specifications Dimensions Material Galvanizing *Thread Pressure Rating MALLEABLE IRON FITTINGS Class 150/PN 20 ASME B16.3 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.3 Class 300/PN 50 ASME B16.3 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.3 MALLEABLE IRON UNIONS Class 150/PN 20 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 Class 250 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 Class 300/PN 50 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 * ASTM B 633. Type I, SC 4, may be supplied as alternate zinc coating per applicable ASME B16 product standard. Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature Pressure Class 150 Class 250 Class 300 (°F) (°C)psi bar psi bar psi bar -20° to 150° -28.9° to 65.6° 300 20.7 500 34.5 600 41.4 200°93.3°265 18.3 455 31.4 550 37.9 250°121.1°225 15.5 405 27.9 505 34.8 300°148.9°185 12.8 360 24.8 460 31.7 350°176.7°150 10.3 315 21.7 415 28.6 400°204.4°110 7.6 270 18.6 370 25.5 450°232.2°75 5.2 225 15.5 325 22.4 500°260.0°––180 12.4 280 19.3 550°287.8°––130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F MALLEABLE IRON FITTINGS 1) Inspect both male and female components prior to assembly. • Threads should be free from mechanical damage, dirt, chips and excess cutting oil. • Clean or replace components as necessary. 2) Application of thread sealant • Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant may be utilized. • Thoroughly mix the thread sealant prior to application. • Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3) Joint Makeup • For sizes up to and including 2" pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for 1⁄2" through 2" thread varies from 41⁄2 turns to 5 turns. • For 2 1⁄2" through 4" sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 2 1⁄2" through 4" thread varies from 51⁄2 turns to 63⁄4 turns. General Assembly of Threaded Fittings PF-11.13 As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. Always ready to protect your most valuable assets. EDDYTHREAD 40 800.325.4467 sales@BullMooseIndustries.com BullMooseTube.com Bull Moose Fire Sprinkler Pipe Product Information Nominal Pipe Size (Inches)1"1-1/4" 1-1/2"2"2-1/2"3"4"6"8" O.D. (in)1.295 1.650 1.900 2.375 I.D. (in)1.083 1.418 1.654 2.123 Empty Weight (lb/ft)1.461 2.070 2.547 3.308 Water Filled Weight (lb/ft)1.860 2.754 3.468 4.842 C.R.R.1.00 1.00 1.00 1.00 Pieces per Lift 70 51 44 30 Lift Weight (lbs) 21' lengths 2,148 2,217 2,353 2,084 Lift Weight (lbs) 24' lengths 2,454 2,534 2,690 2,382 Lift Weight (lbs) 25' lengths 2,557 2,639 2,802 2,481EDDYTHREAD 40 EDDYTHREAD 40 ADVANTAGES: • UL listed (US & Canada) and FM approved • ASTM A135 and A795 Type E, Grade A Certified • Complies with NFPA-13, 13R and 14 • Industry-leading hydraulic characteristics • CRR of 1.0 and greater • All pipe NDT weld tested OTHER BENEFITS/SERVICES: • We have the most stocking locations in the industry, for best delivery and availability • Plain end or roll groove • Eddy Guard II™ bacterial-resistant internal coating • Custom length options • Hot dipped galvanization • Reddi-Pipe® red or black pipe eliminates field painting • Compatible for use in wet, dry, preaction and deluge sprinkler systems • The only maker with EPDs (to help earn LEED points).Exclusive maker of Reddi-Pipe® RED OR BLACK PAINTED PIPE. PRINTED IN USA MFG. #5401206 - REV G 12/08 VSR-S VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 1 OF 3 Stock No. 1144440 The Model VSR-S is a vane type waterfl ow switch for use on wet sprinkler systems that use 1" (25mm), 1¼" (32mm), 1½" (38mm) or 2" (50mm) pipe size. The unit may also be used as a sectional waterfl ow detector on large systems. The unit contains two single pole double throw snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a fl ow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The fl ow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The VSR-S switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A fi eld installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Installation These devices may be mounted in horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a valve, drain or fi tting which changes the direction of the waterfl ow. Select the proper paddle for the pipe size and type of TEE used see Fig. 1 for instructions on changing paddle. The unit has a 1" NPT bushing for threading into a non-corrosive TEE. See Fig. 2 for proper TEE size, type and installation. Use no more than three wraps of tefl on tape. Screw the device into the TEE fi tting as shown in Fig. 2. Care must be taken to properly orient the device for the direction of waterfl ow. The vane must not rub the inside of the TEE or bind in any way. The stem should move freely when operated by hand. The device can also be used in copper or plastic pipe installations with the proper adapters so that the specifi ed TEE fi tting may be installed on the pipe run. Note: Do not leave cover off for an extended period of time. Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com UL, ULC, CSFM Listed and NYMEA Accepted Service Pressure: Up to 300 PSI (20,7 BAR) Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) UL Maximum Surge: 18 FPS (5,5 m/s) Enclosure: Die-cast, red enamel fi nish Cover held in place with tamper resistant screws Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Resistive 10mAmps min. at 24 VDC Conduit Entrances: Two openings provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Usage: Listed plastic, copper and schedule 40 iron pipe. Fits pipe sizes - 1" (25mm), 1 1/4" (32mm), 1 1/2" (38mm) and 2" (50mm) Note: 12 paddles are furnished with each unit, one for each pipe size of threaded and sweat TEE, one for 1" (25mm) CPVC, one for 1" (25mm) CPVC (Central), one for 1" threaded Nibco CPVC, and one for 1 1/2" (38mm) threaded (Japan). Environmental Specifi cations: • NEMA-4/IP54 Rated enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fi tting. • Temperature range: 40° F to 120° F, (4,5° C to 49° C) UL Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090148 (See Fig. 7 for terminations) Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Installation must be perfomed by qualifi ed personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. 4440 PRINTED IN USA MFG. #5401206 - REV G 12/08 VSR-S VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 2 OF 3 COVER TAMPER SWITCH MOUNT SO ARROW ON BUSHING POINTS IN DIRECTION OF WATERFLOW 1” NPT THREADED FITTING ON ALL SIZES RUN OF THE TEE MAY BE THREADED OR SWEAT PIPE DIRECTION OF WATERFLOW DWG# 802-30A Fig. 1 Fig. 2 Notes: 1. The Model VSR-S has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other is used to operate a local audible or visual annunciator. 2. For supervised circuits see “Switch Terminal Connections” drawing and caution note (Fig. 3). Retard Adjustment The time delay is factory set at 30 ± 10 seconds. The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60- 90 seconds). The time delay should be set at the minimum required to prevent false alarms. Fig. 3 Switch Terminal Connections Clamping Plate Terminal OUT G OI N G INCO MI N G DWG# 923-3 To remove knockouts: Place screwdriver at edge of knockouts, not in the center. Screw the device into the tee fi tting as shown. Care must be taken to properly orient the device for the direction of waterfl ow. On sweat tees, no threaded bushings, inserts, or adapters are permitted, unless they comply with the dimensions listed in the chart below. Important - The depth to the inside bottom of the tee should have the following dimensions: DIRECTION OF WATER FLOW DWG# 737-31 Shown with optional Cover Tamper Switch Kit. DWG# 1146-4 DWG# 8810018-2 C (WHT) N.O. (RED) N.C. (BLK) Fig. 7 Cover Tamper Switch Wiring (Shown with cover in place) DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME 4,3MM (1 11/16”)APPROX. DEPTH DWG# 735-33 Approximate Depth Requirement Tee Size Threaded Sweat CPVC 1" x 1" x 1" 2 1/16" 1 3/4" 2 7/16" 1 1/4" x 1 1/4" x 1" 2 7/16" 2 7/16" N/A 1 1/2" x 1 1/2" x 1" 2 11/16" 2 1/4" N/A 2" x 2" x 1" 3 3/16" 2 3/4" N/A DWG# 1146-3A POSITIVE DC OR HOT AC NEGATIVE DC OR NEUTRAL AC WATERFLOW ZONE ON FIRE PANEL BELL EOLRCOMNCNO NONCCOMBreak out thin section of cover when wiring both switches from one conduit entrance. DWG# 1206-2 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Fig. 4 Typical Electrical Connections Fig. 5 Fig. 6 There are 12 paddles furnished with each unit. One for each size of threaded, sweat or plastic TEE as described in Fig. 2. These paddles have raised lettering that shows the pipe size and type of TEE that they are to be used with. The proper paddle must be used. The paddle must be properly attached (see drawing) and the screw that holds the paddle must be securely tightened.Do not use more than three wraps of tefl on tape. PRINTED IN USA MFG. #5401206 - REV G 12/08 VSR-S VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 3 OF 3 Testing The frequency of inspection and testing for the Model VSR-S and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently.) An inspector's test valve (usually located at the end of the most remote branch line) should always be used for test purposes. If there are no provisions for testing the operation of the fl ow detection device on the system, application of the VSR-S is not recommended or advisable. A minimum fl ow of 10 gpm (38 Lpm) is required to activate this device. Please advise the person responsible for testing of the fi re protection system that this system must be tested in accordance with the testing instructions. Maintenance Inspect detectors monthly for leaks. If leaks are found, replace the detector. The VSR-S waterfl ow switch should provide years of trouble- free service. The retard and switch assembly are easily fi eld replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030. There is no maintenance required, only periodic testing and inspection. DWG# 1206-5 GROUND SCREWS 3.50"5.56" (89.0 mm) (59.4 mm) 2.34" (141.2 mm) (52.3 mm) 4.89" 2.00" (50.8 mm) 1"-11 1/2 NPT Mounting Dimensions Waterfl ow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfl ow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Removal • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfl ow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Use a wrench on the fl ats of the bushing. Turn the switch counterclockwise to disengage the pipe threads. • Gently lift with your fi ngers, roll the vane so it will fi t through the hole while continuing to lift the waterfl ow detector. • Lift detector clear of pipe. Design Remote Area Name Remote Area Location Occupancy Classification Density (gpm/sq.ft) Area of Application (sq.ft) Coverage per Sprinkler (sq.ft) Number of Calculated Sprinklers In-Rack Demand (gpm) Special Heads Hose Streams (gpm) Total Water Required (incl. Hose Streams) (gpm) Pressure at Source (psi) Type of System Volume - Entire System Volume (gal) Bedroom Pendants Bedroom Pendants RES 0.05 800 400 2 0 5 45.787 63.37 Wet 46.4 gal Water Supply Information Date Location Source HYDRAULIC CALCULATIONS for 1/31/19 78340 Coyote Canyon Court SRC100 Project Name : Zerbst Residence Contract No. : 17-078 Project Location: At Coyote Canyon Court City: La Quinta, Ca 92253 Date: 3/28/2019 Name of Contractor: Shasta Fire Protection Address: 72120 Northshore Street Phone Number: 760-323-5993 Name of Designer: Kevin Gunn Authority Having Jurisdiction: Riverside County Fire Department City: Thousand Palms, Ca 92276 E-mail: Info@shastafire.com Job Information Contractor Information Notes Date 3/28/2019 Page 1Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Job : Zerbst Residence Hydraulic Analysis for : Bedroom Pendants Water Supply Parameters Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft³) Fluid Dynamic Viscosity, (lb·s/ft²) Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Supply 1 : SRC100 Flow (gpm)Pressure (psi) 0 94.1 1,525 71.48 Inside Hose Flow / Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 5 0 0 5 Hoses Ovehead Sprinkler Flow (gpm) InRack Sprinkler Flow (gpm) Other (custom defined) Sprinkler Flow (gpm) Total Sprinkler Flow (gpm) 40.787 0 0 40.787 Required Margin of Safety (%) BOR13 - Required Pressure (psi) BOR13 - Flow (gpm) Demand w/o System Pump(s) 10 39.45 40.787 N/A Sprinklers Other Date 3/28/2019 Page 2Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Job : Zerbst Residence Hydraulic Analysis for : Bedroom Pendants Pressure (psi)Label Graph Labels Flow (gpm) Values Description 0S1 94.1Supply point #1 - Static 1,525S2 71.48Supply point #2 - Residual 0D1 5.27Elevation Pressure 45.787D2 63.37System Demand Date 3/28/2019 Page 3 Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Job : Zerbst Residence Hydraulic Analysis for : Bedroom Pendants Pressure (psi)Curve Name Curve Intersections & Safety Margins Flow (gpm) Safety MarginIntersection Pressure (psi)@ Flow (gpm) 54.201Supply; Safety Pressure 84.65 21.29 45.787 57.582Supply94.05 30.7 45.787 Open Heads Head Ref. DensityDensity K-Factor PressureFlowPressure (gpm/sq.ft)(gpm/sq.ft)(gpm/psi½)(psi)(gpm)(psi) Flow (gpm) Coverage (sq.ft) Required Calculated Head Type 1 4.9 0.05 20.054 16.75 0.05 16.7520.054400OVERHEAD 2 4.9 0.05 20.054 16.75 0.052 17.920.733400OVERHEAD Date 3/28/2019 Page 4Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Job : Zerbst Residence Node Data : Bedroom Pendants Hydraulic Calculations / Fluid Delivery Time Analysis Node #Elevation ft Hgroup Tot. Pres. psi Discharge gpm K-Factor gpm/psi½ Req. Discharge gpm Req. Pres. psi GPM5 -2 HOSE 40.88 5 5 BOR13 0.5 NODE 39.45 12 11 NODE 33.19 10 11 NODE 18.29 2 10.167 HEAD 17.9 20.733 20.054 16.75 1 10.167 HEAD 16.75 20.054 20.054 16.75 14 -2 NODE 51.94 15 -2 NODE 59.92 SRC100 -2 SUPPLY 63.37 -45.787 Date 3/28/2019 Page 5Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Hydraulic CalculationsJob : Zerbst Residence PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: 1 10 10'-2" 11'-0" 4.9 20.054 20.054 1 1.109 2x(us.90) = 7.92 21.048 7.92 28.968 150 0.0657 16.75 -0.36 1.9 10 12 11'-0" 11'-0" 20.733 40.787 1-1/4 1.4 1x(us.90) = 4.859 3x(us.Tee-Br) = 29.153 155.212 34.012 189.224 150 0.0787 18.29 0 14.9 12 BOR13 11'-0" 0'-6" 0 40.787 1-1/4 1.408 1x(us.90) = 3.308 11.5 3.308 14.808 120 0.1157 33.19 4.55 1.71 BOR13 GPM5 0'-6" -2'-0" 0 40.787 1-1/4 1.245 2.5 0 2.5 150 0.1394 39.45 1.08 0.35 GPM5 14 -2'-0" -2'-0" 5 45.787 1-1/4 1.245 2x(us.90) = 5.488 58.539 5.488 64.027 150 0.1727 40.88 0 11.06 14 15 -2'-0" -2'-0" 0 45.787 1 0 1 0 1 0 7.9826 51.94 0 7.98 15 SRC100 -2'-0" -2'-0" 0 45.787 1-1/4 1.245 19.952 0 19.952 150 0.1727 59.92 0 3.45 SRC100 63.37 2Path No: 2 10 10'-2" 11'-0" 4.9 20.733 20.733 1 1.109 1x(us.Tee-Br) = 9.9 0.833 9.9 10.733 150 0.0699 17.9 -0.36 0.75 10 18.29 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.01 psi due to display rounding. * Maximum Velocity of 12.07 ft/s occurs in the following pipe(s): U6(14-GPM5), U7(SRC100-15) Date 3/28/2019 Page 6Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Device GraphsJob : Zerbst Residence Date 3/28/2019 Page 7Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Design Remote Area Name Remote Area Location Occupancy Classification Density (gpm/sq.ft) Area of Application (sq.ft) Coverage per Sprinkler (sq.ft) Number of Calculated Sprinklers In-Rack Demand (gpm) Special Heads Hose Streams (gpm) Total Water Required (incl. Hose Streams) (gpm) Pressure at Source (psi) Type of System Volume - Entire System Volume (gal) Bedroom Sidewalls Bedroom Sidewalls RES 0.063 576 288 2 0 5 41.044 56.68 Wet 46.4 gal Water Supply Information Date Location Source HYDRAULIC CALCULATIONS for 1/31/19 78340 Coyote Canyon Court SRC100 Project Name : Zerbst Residence Contract No. : 17-078 Project Location: At Coyote Canyon Court City: La Quinta, Ca 92253 Date: 3/28/2019 Name of Contractor: Shasta Fire Protection Address: 72120 Northshore Street Phone Number: 760-323-5993 Name of Designer: Kevin Gunn Authority Having Jurisdiction: Riverside County Fire Department City: Thousand Palms, Ca 92276 E-mail: Info@shastafire.com Job Information Contractor Information Notes Date 3/28/2019 Page 8Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Job : Zerbst Residence Hydraulic Analysis for : Bedroom Sidewalls Water Supply Parameters Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft³) Fluid Dynamic Viscosity, (lb·s/ft²) Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Supply 1 : SRC100 Flow (gpm)Pressure (psi) 0 94.1 1,525 71.48 Inside Hose Flow / Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 5 0 0 5 Hoses Ovehead Sprinkler Flow (gpm) InRack Sprinkler Flow (gpm) Other (custom defined) Sprinkler Flow (gpm) Total Sprinkler Flow (gpm) 36.044 0 0 36.044 Required Margin of Safety (%) BOR13 - Required Pressure (psi) BOR13 - Flow (gpm) Demand w/o System Pump(s) 10 36.92 36.044 N/A Sprinklers Other Date 3/28/2019 Page 9Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Job : Zerbst Residence Hydraulic Analysis for : Bedroom Sidewalls Pressure (psi)Label Graph Labels Flow (gpm) Values Description 0S1 94.1Supply point #1 - Static 1,525S2 71.48Supply point #2 - Residual 0D1 6.5Elevation Pressure 41.044D2 56.68System Demand Date 3/28/2019 Page 10 Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Job : Zerbst Residence Hydraulic Analysis for : Bedroom Sidewalls Pressure (psi)Curve Name Curve Intersections & Safety Margins Flow (gpm) Safety MarginIntersection Pressure (psi)@ Flow (gpm) 52.148Supply; Safety Pressure 84.65 27.98 41.044 55.45Supply94.05 37.39 41.044 Open Heads Head Ref. DensityDensity K-Factor PressureFlowPressure (gpm/sq.ft)(gpm/sq.ft)(gpm/psi½)(psi)(gpm)(psi) Flow (gpm) Coverage (sq.ft) Required Calculated Head Type 3 4 0.063 18.022 20.3 0.063 20.318.022288OVERHEAD 4 4 0.063 18.022 20.3 0.063 20.318.022288OVERHEAD Date 3/28/2019 Page 11Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Job : Zerbst Residence Node Data : Bedroom Sidewalls Hydraulic Calculations / Fluid Delivery Time Analysis Node #Elevation ft Hgroup Tot. Pres. psi Discharge gpm K-Factor gpm/psi½ Req. Discharge gpm Req. Pres. psi GPM5 -2 HOSE 38.28 5 5 BOR13 0.5 NODE 36.92 12 11 NODE 31.01 11 15 NODE 20.79 4 13 HEAD 20.3 18.022 4 18.022 20.3 3 13 HEAD 20.3 18.022 4 18.022 20.3 14 -2 NODE 47.31 15 -2 NODE 53.87 SRC100 -2 SUPPLY 56.68 -41.044 Date 3/28/2019 Page 12Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Hydraulic CalculationsJob : Zerbst Residence PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: 4 11 13'-0" 15'-0" 4 18.022 18.022 1 1.109 1x(us.Tee-Br) = 9.9 2x(us.90) = 7.92 7.333 17.819 25.153 150 0.0539 20.3 -0.87 1.36 11 12 15'-0" 11'-0" 18.022 36.044 1-1/4 1.4 4x(us.90) = 19.435 3x(us.Tee-Br) = 29.153 86.927 48.588 135.515 150 0.0626 20.79 1.73 8.48 12 BOR13 11'-0" 0'-6" 0 36.044 1-1/4 1.408 1x(us.90) = 3.308 11.5 3.308 14.808 120 0.0921 31.01 4.55 1.36 BOR13 GPM5 0'-6" -2'-0" 0 36.044 1-1/4 1.245 2.5 0 2.5 150 0.1109 36.92 1.08 0.28 GPM5 14 -2'-0" -2'-0" 5 41.044 1-1/4 1.245 2x(us.90) = 5.488 58.539 5.488 64.027 150 0.141 38.28 0 9.03 14 15 -2'-0" -2'-0" 0 41.044 1 0 1 0 1 0 6.5589 47.31 0 6.56 15 SRC100 -2'-0" -2'-0" 0 41.044 1-1/4 1.245 19.952 0 19.952 150 0.141 53.87 0 2.81 SRC100 56.68 2Path No: 3 11 13'-0" 15'-0" 4 18.022 18.022 1 1.109 1x(us.Tee-Br) = 9.9 2x(us.90) = 7.92 7.333 17.819 25.153 150 0.0539 20.3 -0.87 1.36 11 20.79 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.01 psi due to display rounding. * Maximum Velocity of 10.82 ft/s occurs in the following pipe(s): U6(14-GPM5), U7(SRC100-15) Date 3/28/2019 Page 13Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg Device GraphsJob : Zerbst Residence Date 3/28/2019 Page 14Copyright © 2002-2016 Tyco Fire Protection Products File: C:\Users\kevin\Documents\Fire\Shasta\Projects\Zerbst Residence 18-078\Working\Zerbst Residence Fire Sprinkler Plans.dwg 1 Kayli Alford From:Linda Winesburg <lwinesburg@shastafire.com> Sent:Thursday, May 7, 2020 8:33 AM To:Kayli Alford Subject:FSS2019-0043 ** EXTERNAL: This message originated outside of the City of La Quinta. Please use proper judgement and caution when opening attachments, clicking links or responding to requests for information. ** Hi there – good morning to you. So, this permit is most likely expired – we, and the contractor, thought we had done a sprinkler final back in December before Christmas – he even paid us in full on 12/12 Apparently it didn’t get logged – or didn’t pass – or something… Please extend the permit – let me know when we can go online and pay it and then let’s schedule ASAP… Thanks L Linda J. Winesburg Shasta Fire Protection, Inc. 72120 Northshore Street #C Thousand Palms, CA 92276 760.404.1350 Office of the Fire Marshal City of La Quinta 78-495 Calle Tampico, La Quinta CA 92253 • Phone (760)777-7000 •Direct (760)777-7074 4/18/2019 John Paulus Shasta Fire Protection 72-120 Northshore St. Thousand Palms, CA 92276 Re: Residential Fire Sprinkler Plan Review – Zerbst Residence FSS2019-0043 78-340 Coyote Canyon Ct. La Quinta, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777-7131. SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is subject to field inspection. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Edgar Gonzalez Fire Safety Specialist