Loading...
FSS2019-0080ADDITIONAL SITES CHRONOLOGY CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE KAYLI ALFORD 3/2/2020 3/2/2020 CONTRACTOR REQUESTED INSPECTION, PERMIT EXPIRED AS OF 2/18/20. INFORMED HIM WE WILL REQUIRE AN EXTENSION REQUEST LETTER AND EXTENSION FEE OF $40.25 EXTENSION REQUEST LETTER RECEIVED. NOTE KAYLI ALFORD 3/4/2020 3/4/2020 EXTENDED PERMIT EXP DATE FROM 2/18/20 TO 3/5/20 (TOMORROW) SO CONTRACTOR IS ABLE TO PAY EXTENSION FEE VIA ETRAKIT PAYMENT RECEIVED - PERMIT WILL BE EXTENDED 6 MOS FROM TODAY OK TO EXTEND PER KOHL. CONDITIONS Description: FRICKLETON / BRES2018-0172 / FIRE SPRINKLER Type: FIRE SPRINKLER (WEB)Subtype: COMMERCIAL/INDUSTRIAL Status: FINALED Applied: 6/21/2019 ECON Parcel No: 777100064 Site Address: 80090 VIA CAPRI LA QUINTA,CA 92253 Approved: 7/10/2019 KHET Subdivision: TR 29894-2 Block: Lot: 37 Issued: 8/16/2019 KAL Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 3/5/2020 crw Valuation: $10,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Friday, February 03, 2023 4:31:18 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0080 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT ARC MECHANICAL P O BOX 1354 YUCCA VALLEY CA 92286 (760)289-9054 KFOSTERARC@GMAIL. COM CONTRACTOR ARC MECHANICAL P O BOX 1354 YUCCA VALLEY CA 92286 (760)289-9054 KFOSTERARC@GMAIL. COM OWNER JAMES FRICKLETON 3012 W 117TH ST LEAWOOD KS 66211 (760)289-9054 READY TO ISSUE CHECKLIST AARON HICKSON 6/24/2019 8/16/2019 COMPLETE CONTRACTOR NEEDS TO RENEW CITY BL BEFORE ISSUANCE. BL RENEWED 7/11/19. EXPIRES 5/31/20. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY Credit Card Fee 101-0000-43505 0 $11.50 $11.50 6/21/19 WEB3817 CREDIT ARC MECHANICAL ECON Total Paid for Credit Card Fee: $11.50 $11.50 FIRE SPRINKLER SYSTEMS COMMERCIAL/INDUSTR IAL 101-0000-42421 0 $234.00 $234.00 6/21/19 WEB3817 CREDIT ARC MECHANICAL ECON FIRE SPRINKLER SYSTEMS COMMERCIAL/INDUSTR IAL PC 101-0000-42420 0 $390.00 $390.00 6/21/19 WEB3817 CREDIT ARC MECHANICAL ECON FIRE STAFF - PER HOUR 101-0000-42420 0.25 $40.25 $40.25 3/4/20 WEB4647 CREDIT ARC MECHANICAL ECON Total Paid for FIRE FEES: $664.25 $664.25 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 6/21/19 WEB3817 CREDIT ARC MECHANICAL ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 Printed: Friday, February 03, 2023 4:31:18 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0080 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/21/2019 EtrakitContractor 1ST SUBMITTAL SHOP DRAWING SHEET 1 Frickleton Residence 06- 21-19.pdf 1 BOND INFORMATION INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 8/22/2019 8/22/2019 APPROVED OVERHEAD HYRO KHET 8/22/2019 8/22/2019 APPROVED FIRE FINAL**KHET 3/5/2020 3/5/2020 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) AARON HICKSON 6/21/2019 6/24/2019 6/24/2019 1ST FIRE (2 WK)EDGAR GONZALEZ 6/21/2019 7/5/2019 7/10/2019 APPROVED- CONDITIONS SEE ATTACHED CONDITIONS AND APPROVED PLAN SET. PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/21/19 WEB3817 CREDIT ARC MECHANICAL ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$690.75 $690.75 Printed: Friday, February 03, 2023 4:31:18 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0080 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/21/2019 EtrakitContractor 1ST SUBMITTAL SHOP DRAWINGS SHEET 2&3 frickleton sprinkler sheet 2and3 complete.pdf 1 DOC 6/21/2019 EtrakitContractor 1ST SUBMITTAL CALCS / WATER LETTER Frickleton Residence CALCS.pdf 1 DOC 7/10/2019 EDGAR GONZALEZ Frickleton Residence 06- 21-19 - FIRE APPROVED SET.pdf Frickleton Residence 06- 21-19 - FIRE APPROVED SET.pdf 1 DOC 7/10/2019 EDGAR GONZALEZ frickleton sprinkler sheet 2and3 complete - FIRE APPROVED SET..pdf frickleton sprinkler sheet 2and3 complete - FIRE APPROVED SET..pdf 1 DOC 7/10/2019 EDGAR GONZALEZ FSS2019-0080 - FRICKLETON RESIDENCE - 80090 VIA CAPRI - FIRE SPRINKLER (COA).docx FSS2019-0080 - FRICKLETON RESIDENCE - 80090 VIA CAPRI - FIRE SPRINKLER (COA).docx 1 DOC 8/21/2019 KAYLI ALFORD JOB CARD FSS2019- 0080.pdf JOB CARD FSS2019- 0080.pdf 1 DOC 3/2/2020 KAYLI ALFORD Frickleton Permit Extension Letter.pdf Frickleton Permit Extension Letter.pdf 0 Printed: Friday, February 03, 2023 4:31:18 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0080 FRICKLETON RESIDENCE Fire Sprinkler Reports for OFFICE (2 SPRINKLERS) Prepared By: KIRTH FOSTER ARC MECHANICAL P.O. BOX 1354 YUCCA VALLEY, CA 92284 760-289-9054 JUNE 21, 2019 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. RM Fire Sprinkler Design FRICKLETON RESIDENCE La Verne, CA 91750 Page 2 General Project Data Report General Data Project Title: FRICKLETON RESIDENCE Project File Name: OFFICE..fiw Designed By: KIRTH FOSTER Date: JUNE 21, 2019 Code Reference: NFPA 13D (2016) Approving Agency: Client Name: OFFICE Phone: Address: (2 SPRINKLERS) City, State Zip Code: Company Name: ARC MECHANICAL Representative: KIRTH FOSTER Company Address: P.O. BOX 1354 City And State: YUCCA VALLEY, CA 92284 Phone: 760-289-9054 Building Name: FRICKLETON RESIDENCE Building Owner: Contact at Building: Phone at Building: Address Of Building: 80-090 VIA CAPRI City, State Zip Code: LA QUINTA, CA 92253 Project Data Description Of Hazard: RESIDENTIAL Sprinkler System Type: Wet Design Area Of Water Application:648 ft² Maximum Area Per Sprinkler: 324 ft² Default Sprinkler K-Factor: 4.90 K Default Pipe Material: BLAZEMASTER CPVC Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 5.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: VIKING Model: VK494 Size: 1/2" Temperature Rating: 155 F Water Supply Test Data Source Of Information: CVWD Test Hydrant ID: Date Of Test: 10-01-18 Hydrant Elevation: 0 ft Static Pressure: 101.52 psi Test Flow Rate: 0.00 gpm Test Residual Pressure: 0.00 psi Calculated System Flow Rate: 39.49 gpm Calculated Inflow Residual Pressure: 62.11 psi Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 12.04 psi Minimum Desired Flow Density: 0.05 gpm/ft² Number Of Active Nodes: 18 Number Of Active Pipes: 20 Number Of Inactive Pipes: 0 Number Of Active Sprinklers: 2 Number Of Inactive Sprinklers: 0 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. RM Fire Sprinkler Design FRICKLETON RESIDENCE La Verne, CA 91750 Page 3 Fire Sprinkler Input Data Node Input Data Node No. Node Description Branch Description Area Group Branch Dia. (in) Sprinkler KFactor (K) Branch Len. (ft) Pressure Estimate (psi) Branch Stnd Fittings Node Elev (ft) Branch Non- Stnd Fittings (ft) Non-Sprinkler Flow (gpm) Branch Sprk KFactor (K) 1 Sprinkler ---- ---- 0.000 4.90 0.0 12.04 ---- 13.00 0.0 0.00 0.00 2 Sprinkler ---- ---- 0.000 4.90 0.0 12.73 ---- 13.00 0.0 0.00 0.00 5 No Discharge ---- ---- 0.000 N/A 0.0 12.20 ---- 13.50 0.0 0.00 0.00 10 No Discharge ---- ---- 0.000 N/A 0.0 12.81 ---- 13.50 0.0 0.00 0.00 15 No Discharge ---- ---- 0.000 N/A 0.0 30.86 ---- 10.50 0.0 0.00 0.00 20 No Discharge ---- ---- 0.000 N/A 0.0 33.97 ---- 10.50 0.0 0.00 0.00 25 No Discharge ---- ---- 0.000 N/A 0.0 31.17 ---- 19.50 0.0 0.00 0.00 30 No Discharge ---- ---- 0.000 N/A 0.0 34.21 ---- 20.50 0.0 0.00 0.00 35 No Discharge ---- ---- 0.000 N/A 0.0 39.25 ---- 10.50 0.0 0.00 0.00 40 No Discharge ---- ---- 0.000 N/A 0.0 40.13 ---- 10.50 0.0 0.00 0.00 45 No Discharge ---- ---- 0.000 N/A 0.0 43.85 ---- 10.50 0.0 0.00 0.00 50 No Discharge ---- ---- 0.000 N/A 0.0 44.50 ---- 10.50 0.0 0.00 0.00 55 No Discharge ---- ---- 0.000 N/A 0.0 49.31 ---- 2.00 0.0 0.00 0.00 60 Non-Sprinkler ---- ---- 0.000 N/A 0.0 50.49 ---- 1.00 0.0 5.00 0.00 70 No Discharge ---- ---- 0.000 N/A 0.0 53.32 ---- -3.00 0.0 0.00 0.00 80 No Discharge ---- ---- 0.000 N/A 0.0 54.10 ---- -3.00 0.0 0.00 0.00 90 No Discharge ---- ---- 0.000 N/A 0.0 60.19 ---- -3.00 0.0 0.00 0.00 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. RM Fire Sprinkler Design FRICKLETON RESIDENCE La Verne, CA 91750 Page 4 Fire Sprinkler Input Data Node Input Data (cont'd) Node No. Node Description Branch Description Area Group Branch Dia. (in) Sprinkler KFactor (K) Branch Len. (ft) Pressure Estimate (psi) Branch Stnd Fittings Node Elev (ft) Branch Non- Stnd Fittings (ft) Non-Sprinkler Flow (gpm) Branch Sprk KFactor (K) 100 No Discharge ---- ---- 0.000 N/A 0.0 62.11 ---- -3.00 0.0 0.00 0.00 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. RM Fire Sprinkler Design FRICKLETON RESIDENCE La Verne, CA 91750 Page 5 Fire Sprinkler Output Data Overall Node Groupings Output Data Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. Node End. Node Type Group Flow Rate (gpm) At Beg. Node (gpm) Out (+) (gpm) In (-) (gpm) Residual Pressure (psi) Flow At Beg. Node (gpm) 1 5 0 -17.00 17.00 0.00 0.00 12.04 2 10 0 -17.48 17.48 0.00 0.00 12.73 0.00024 5 1 0 17.00 0.00 0.00 0.00 12.20 0.00013 5100 -17.00 10 2 0 17.48 0.00 0.00 0.00 12.81 0.00002 10 5 0 17.00 10 15 0 -34.49 15 10 0 34.49 0.00 0.00 0.00 30.86 -0.00001 15 20 0 -23.36 15 25 0 -11.12 20 15 0 23.36 0.00 0.00 0.00 33.97 0.00000 20 45 0 -17.12 20 25 0 -6.24 25 15 0 11.12 0.00 0.00 0.00 31.17 0.00000 25 20 0 6.24 25 30 0 -17.36 30 25 0 17.36 0.00 0.00 0.00 34.21 0.00000 30 40 0 -8.29 30 35 0 -9.08 35 30 0 9.08 0.00 0.00 0.00 39.25 0.00000 35 40 0 -9.08 40 30 0 8.29 0.00 0.00 0.00 40.13 0.00000 40 35 0 9.08 40 45 0 -17.36 45 20 0 17.12 0.00 0.00 0.00 43.85 -0.00001 45 40 0 17.36 45 50 0 -34.49 50 45 0 34.49 0.00 0.00 0.00 44.50 0.00000 50 55 0 -34.49 55 50 0 34.49 0.00 0.00 0.00 49.31 0.00000 55 60 0 -34.49 60 55 0 34.49 0.00 5.00 0.00 50.49 0.00003 60 70 0 -39.49 70 60 0 39.49 0.00 0.00 0.00 53.32 0.00000 70 80 0 -39.49 80 70 0 39.49 0.00 0.00 0.00 54.10 0.02375 80 90 0 -39.46 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. RM Fire Sprinkler Design FRICKLETON RESIDENCE La Verne, CA 91750 Page 6 Fire Sprinkler Output Data Overall Node Groupings Output Data (cont'd) Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. Node End. Node Type Group Flow Rate (gpm) At Beg. Node (gpm) Out (+) (gpm) In (-) (gpm) Residual Pressure (psi) Flow At Beg. Node (gpm) 90 80 0 39.46 0.00 0.00 0.00 60.19 -0.02374 90 100 0 -39.49 100 90 0 39.49 0.00 0.00 -39.49 62.11 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. RM Fire Sprinkler Design FRICKLETON RESIDENCE La Verne, CA 91750 Page 7 Fire Sprinkler Output Data Overall Pipe Output Data Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 1 4.90 13.00 17.00 12.04 1.00 17.00 0.05040 0.50 0.378 5 0.00 13.50 0.00 12.20 1.101 17.00 E 7.00 -0.217 BLAZEMASTER CPVC 150 5.73 0 7.50 0.162 2 4.90 13.00 17.48 12.73 1.00 17.48 0.05307 0.50 0.292 10 0.00 13.50 0.00 12.81 1.101 17.48 T 5.00 -0.217 BLAZEMASTER CPVC 150 5.89 0 5.50 0.075 5 0.00 13.50 0.00 12.20 1.00 0.00 0.05040 11.00 0.605 10 0.00 13.50 0.00 12.81 1.101 17.00 ----- 1.00 0.000 BLAZEMASTER CPVC 150 5.73 0 12.00 0.605 10 0.00 13.50 0.00 12.81 1.00 0.00 0.18651 46.83 16.754 15 0.00 10.50 0.00 30.86 1.101 34.49 2F5ET 43.00 1.299 BLAZEMASTER CPVC 150 11.62 0 89.83 18.053 15 0.00 10.50 0.00 30.86 1.00 23.36 0.09075 23.25 3.108 20 0.00 10.50 0.00 33.97 1.101 23.36 2T 11.00 0.000 BLAZEMASTER CPVC 150 7.87 0 34.25 3.108 15 0.00 10.50 0.00 30.86 1.00 11.12 0.02298 99.92 4.204 25 0.00 19.50 0.00 31.17 1.101 11.12 10ET 83.00 -3.897 BLAZEMASTER CPVC 150 3.75 0 182.92 0.307 20 0.00 10.50 0.00 33.97 1.00 6.24 0.00790 81.75 1.096 25 0.00 19.50 0.00 31.17 1.101 6.24 6ET 57.00 -3.897 BLAZEMASTER CPVC 150 2.10 0 138.75 -2.801 25 0.00 19.50 0.00 31.17 1.00 0.00 0.05241 41.25 3.472 30 0.00 20.50 0.00 34.21 1.101 17.36 2ET 25.00 -0.433 BLAZEMASTER CPVC 150 5.85 0 66.25 3.039 30 0.00 20.50 0.00 34.21 1.00 9.08 0.01578 25.33 0.715 35 0.00 10.50 0.00 39.25 1.101 9.08 2ET 20.00 4.330 BLAZEMASTER CPVC 150 3.06 0 45.33 5.045 30 0.00 20.50 0.00 34.21 1.00 8.29 0.01334 60.58 1.595 40 0.00 10.50 0.00 40.13 1.101 8.29 5E4T 59.00 4.330 BLAZEMASTER CPVC 150 2.79 0 119.58 5.925 35 0.00 10.50 0.00 39.25 1.00 0.00 0.01578 40.75 0.880 40 0.00 10.50 0.00 40.13 1.101 9.08 T 15.00 0.000 BLAZEMASTER CPVC 150 3.06 0 55.75 0.880 20 0.00 10.50 0.00 33.97 1.00 17.12 0.05106 130.58 9.884 45 0.00 10.50 0.00 43.85 1.101 17.12 F5E3T 63.00 0.000 BLAZEMASTER CPVC 150 5.77 0 193.58 9.884 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. RM Fire Sprinkler Design FRICKLETON RESIDENCE La Verne, CA 91750 Page 8 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 40 0.00 10.50 0.00 40.13 1.00 0.00 0.05241 40.00 3.721 45 0.00 10.50 0.00 43.85 1.101 17.36 3ET 31.00 0.000 BLAZEMASTER CPVC 150 5.85 0 71.00 3.721 45 0.00 10.50 0.00 43.85 1.25 0.00 0.05911 3.00 0.650 50 0.00 10.50 0.00 44.50 1.394 34.49 E 8.00 0.000 BLAZEMASTER CPVC 150 7.25 0 11.00 0.650 50 0.00 10.50 0.00 44.50 1.25 0.00 0.05911 8.50 1.123 55 0.00 2.00 0.00 49.31 1.394 34.49 C 10.50 3.681 BLAZEMASTER CPVC 150 7.25 0 19.00 4.804 55 0.00 2.00 0.00 49.31 1.25 0.00 0.09485 2.00 0.749 60 0.00 1.00 5.00 50.49 1.265 34.49 ET 5.90 0.433 TYPE L COPPER 150 8.80 0 7.90 1.182 60 0.00 1.00 5.00 50.49 1.25 5.00 0.12185 6.00 1.097 70 0.00 -3.00 0.00 53.32 1.265 39.49 EG 3.00 1.732 TYPE L COPPER 150 10.08 0 9.00 2.829 70 0.00 -3.00 0.00 53.32 2.00 0.00 0.01169 60.00 0.786 80 0.00 -3.00 0.00 54.10 2.047 39.49 E 7.22 0.000 SCH. 40 PVC 150 3.85 0 67.22 0.786 80 Meter -3.00 54.10 39.46 90 6.00 psi -3.00 60.19 90 0.00 -3.00 0.00 60.19 1.50 0.00 0.05229 30.00 1.924 100 0.00 -3.00 0.00 62.11 1.505 39.49 TG 6.80 0.000 TYPE K COPPER 150 7.12 0 36.80 1.924 Fitting Legend: F = 45 Degree Elbow, E = 90 Degree Elbow, L = Long Turn Elbow, T = Tee or Cross, B = Butterfly Valve, G = Gate Valve, C = Check Valve Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. RM Fire Sprinkler Design FRICKLETON RESIDENCE La Verne, CA 91750 Page 9 Fire Sprinkler Output Data Overall Sprinkler Output Data Flowing Sprinkler Node No. Area Group Code Sprinkler KFactor (K) Sprinkler Elevation (feet) Residual Pressure (psi) Flowing Area (ft²) Flowing Density (gpm/ft²) Sprinkler Discharge (gpm) 1 4.90 13.00 12.04 324.00 0.052 17.00 Sub Totals For Non-Group 324.00 0.052 17.00 2 4.90 13.00 12.73 324.00 0.054 17.48 Sub Totals For Non-Group 324.00 0.054 17.48 Totals For All Groups 648.00 0.053 34.49 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. RM Fire Sprinkler Design FRICKLETON RESIDENCE La Verne, CA 91750 Page 10 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number: 1 HMD Actual Residual Pressure: 12.04 psi HMD Actual GPM: 17.00 gpm Sprinkler Summary Sprinkler System Type: Wet Specified Area Of Application: 648.00 ft² Minimum Desired Density: 0.050 gpm/ft² Application Average Density: 0.053 gpm/ft² Application Average Area Per Sprinkler: 324.00 ft² Sprinkler Flow: 34.49 gpm Average Sprinkler Flow: 17.24 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity ( In Pipe 10 - 15 ) 11.62 ft/sec Maximum Velocity Pressure ( In Pipe 10 - 15 ) 0.91 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0076 psi Actual Average Nodal Pressure Imbalance: 0.0012 psi Actual Maximum Nodal Flow Imbalance: 0.0238 gpm Actual Average Nodal Flow Imbalance: 0.0027 gpm Overall Network Summary Number Of Unique Pipe Sections: 20 Number Of Flowing Sprinklers: 2 Pipe System Water Volume: 44.25 gal Sprinkler Flow: 34.49 gpm Non-Sprinkler Flow: 5.00 gpm Minimum Required Residual Pressure At System Inflow Node:62.11 psi Demand Flow At System Inflow Node: 39.49 gpm freedom® residential concealed pendent sprinkler vk494 (k4.9) tecHnical data the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com visit the viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 1 of 5 Form No. F_012116 17.04.20 Rev 17.2 1. description Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL- US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2.listinGs and approvals Ul listed (c-Ul-Us-eU): Category VKKW Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3.tecHnical dataSpecifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. material standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-C51000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene cover plate materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic ordering information: (Also refer to the current Viking price list.) Viking Freedom® Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. cover plate assembly: Base Part No. 13504 (2-3/4” diameter), Base Part No. 13642 (3-5/16” diameter), or Base Part No. 15394 (square cover plate, 3-5/16” diameter) Replaces Form No. F_012116 Rev 17.1 (added alt. material for yoke) freedom® residential concealed pendent sprinkler vk494 (k4.9) tecHnical data the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com visit the viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 2 of 5 Form No. F_012116 17.04.20 Rev 17.2 Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. available finishes and temperature ratings: Refer to Table 1. accessories: (Also refer to the Viking website.) sprinkler Wrenches**: A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. sprinkler cabinet: Part No. 01731A (available since 1971) 4. installation Refer to appropriate NFPA Installation Standards. 5. operation During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. . Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUarantee For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. table 1: available sprinkler temperatUre ratinGs and finisHes sprinkler temperature classification sprinkler nominal temperature rating1 maximum ambient ceiling temperature2 temperature rating of the cover assembly (required)3 cover plate base part number4 large cover plate base part number4 square cover plate base part number4 bulb color Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C)13504 13642 15394 Red Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C)13504 13642 15394 Green sprinkler finishes: Brass and ENT cover plate finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black corrosion resistant coatings5: ENT footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 5 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. freedom® residential concealed pendent sprinkler vk494 (k4.9) tecHnical data the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com visit the viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 3 of 5 Form No. F_012116 17.04.20 Rev 17.2 approval chart viking vk494, 4.9 k-factor residential concealed pendent sprinkler for systems designed to nfpa 13d or nfpa 13r. for systems designed to nfpa 13, refer to the design criteria. for ceiling types refer to current editions of nfpa 13, 13r or 13d sprinkler base part number 1 sin npt thread size nominal k-factor maximum Water Wor- king pressureinchesmmU.s. metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) max. coverage area 6 W X l ft. X ft. (m X m) flow Gpm (lpm) pressure psi (bar)Deflector to ceiling installation type listings and approvals3,5 minimum spacing ft. (m)155 °F (68 °C), 200 °F (93 °C) Temperature Rated Sprinklers 4 12 X 12 (3.7 X 3.7) 13 (49.2) 7.0 (0.48) Refer to Figure 2 Concealed with Cover Plate Assembly. See Footnote 9. See Footnotes 7,10, & 11 8 (2.4) 14 X 14 (4.3 X 4.3) 13 (49.2) 7.0 (0.48) 16 X 16 (4.9 X 4.9) 13 (49.2) 7.0 (0.48) 18 X 18 (5.5 X 5.5) 17 (64.4) 12.0 (0.83) 20 X 20 (6.1 X 6.1) 20 (75.7) 16.7 (1.15) footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4 Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5 Meets New York City requirements, effective July 1, 2008. 6 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 7 Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). 9 Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 10 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 9. 11 C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) freedom® residential concealed pendent sprinkler vk494 (k4.9) tecHnical data the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com visit the viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 4 of 5 Form No. F_012116 17.04.20 Rev 17.2 desiGn criteria (Also refer to the Approval Chart on page 3.) Ul listing requirements (c-Ul-Us-eU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). note: concealed sprinklers must be installed in neutral or negative pressure plenums only. important: always refer to bulletin form no. f_080415 - best practices for residential sprinkler Handling and installation. also refer to form no. f_080614 for general care, installation, and maintenance information. viking sprinklers are to be in- stalled in accordance with the latest edition of viking technical data, the appropriate standards of nfpa and any other similar authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. final approval and acceptance of all residential sprinkler installations must be obtained from the authorities Having Jurisdiction. sprinkler and adapter assembly • protective cap removed • Use wrench 14047W/b** step 1: carefully slide the wrench sideways around the deflector and pins sprinkler Wrench part no. 14047W/b** ** a 1/2” ratchet is required (not available from viking) 2-1/4” (57 mm) diameter opening required in the ceiling. step 2: carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. figure 1: sprinkler installation and proper Wrench Usage never install the sprinkler by applying the installation wrench across the frame arms. do not overtighten. Use only the designated sprinkler wrenches, viking part numbers 14047W/b** or 14031**. a leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. sprinkler wrench flat sprinkler frame arms freedom® residential concealed pendent sprinkler vk494 (k4.9) tecHnical data the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com visit the viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 5 of 5 Form No. F_012116 17.04.20 Rev 17.2 figure 2: sprinkler dimensions and cover installation 1/2” (15 mm) npt 2-1/4”(58 mm)2-9/16” (65 mm) maximum 2-1/16” (52 mm) minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)note: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. figure 3: identification of custom paint for concealed covers All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label.FACTORY APPLIE D C USTO M P AI NT COLORfigure 4: square cover assembly 15394 3-5/16” (84 mm) Replaces Form No. F_012116 Rev 17.1 (added alt. material for yoke) ARC MECHANICAL CSL #963841 C-16 C- 36 FIRE SUPPRESSION PLUMBING HYDRONICS P.O BOX 1354 YUCCA VALLEY, CA. 92286 760-289-9054 3/2/2020 PAGE 1 OF 2 PROJECT INFORMATION FSS2019-0080 80090 VIA CAPRI FRICKLETON RESIDENCE RESPECFULLY REQUESTING FIRE SPRINKLER PERMIT EXTENTION FOR FSS2019-0080 80090 VIA CAPRI FRICKLETON RESIDENCE THANK YOU KIRTH FOSTER PRINCIPAL ARC MECHANICAL CSL #963841 C-16 C- 36 FIRE SUPPRESSION PLUMBING HYDRONICS P.O BOX 1354 YUCCA VALLEY, CA. 92286 ARC MECHANICAL CSL #963841 C-16 C- 36 FIRE SUPPRESSION PLUMBING HYDRONICS P.O BOX 1354 YUCCA VALLEY, CA. 92286 SCHEDULE OF VALUES Office of the Fire Marshal City of La Quinta 78-495 Calle Tampico, La Quinta CA 92253 • Phone (760)777-7000 •Direct (760)777-7074 7/10/2019 Kirth Foster Arch Mechanical Inc. PO Box 1354 Yucca Valley, CA Re: Residential Fire Sprinkler Plan Review – Frickleton Residence FSS2019-0080 80090 Via Capri La Quinta, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777-7131. SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing structural integrity. Review of this plan does not authorize or approve any omission or deviation from all applicable regulations. Final approval is subject to field inspection. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Edgar Gonzalez Fire Safety Specialist 79485 Calle Tampico La Quinta, CA 92253 Main Number (760) 777-7158 Inspection Number → (760)777-7131 CITY OF LA QUINTA FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 80090 VIA CAPRI PERMIT# : FSS2019-0080 DATE ISSUED: 8/16/2019 DESCRIPTION: FRICKLETON / BRES2018-0172 / FIRE SPRINKLER CONTRACTOR: ARC MECHANICAL HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: 79485 Calle Tampico La Quinta, CA 92253 Main Number (760) 777-7158 Inspection Number → (760)777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. The inspection hotline for the City of La Quinta is (760)777-7131 B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.