Loading...
FSS2019-0108ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT ORNNELL FIRE SPRINKLER INC 22421 BARTON ROAD PMB #319 GRAND TERRACE CA 92313 (909)783-3817 ORNNELL909FIRE@AOL .COM CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST ARMANDO MAGALLON 7/26/2019 PENDING CONTRACTOR NEEDS BL BEFORE PERMIT ISSUANCE CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES TELEPHONE CALL ARMANDO MAGALLON 8/15/2019 8/15/2019 I CALLED APPLICANT AND LET HIM KNOW PLANS ARE APPROVED WITH CONDITIONS PENDING BL. APPLICANT STILL NEDS TO PICKUP JOB CARD CONDITIONS Description: THE GYM / FIRE SPRIKLER T.I. Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 7/25/2019 ECON Parcel No: 600390018 Site Address: 46760 COMMERCE CT LA QUINTA,CA 92253 Approved: 8/6/2019 AMA Subdivision: PM 29351 Block: Lot: 8 Issued: 8/26/2019 JLIM Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 8/26/2019 crw Valuation: $3,000.00 Occupancy Type: Construction Type: Expired: 2/22/2020 crw No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Adding fire sprinkler protection to accommodate alterations to an existing gym Printed: Tuesday, February 14, 2023 12:16:08 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0108 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL BILL TO ORNNELL FIRE SPRINKLER INC 22421 BARTON ROAD PMB #319 GRAND TERRACE CA 92313 (909)783-3817 ORNNELL909FIRE@AOL .COM CONTRACTOR ORNNELL FIRE SPRINKLER INC 22421 BARTON ROAD PMB #319 GRAND TERRACE CA 92313 (909)783-3817 ORNNELL909FIRE@AOL .COM OWNER THE GYM 46760 COMMERCE CT LA QUINTA CA 92253 (909)783-3817 INSPECTIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY Credit Card Fee 101-0000-43505 0 $7.47 $7.47 7/25/19 WEB3935 CREDIT ORNNELL FIRE SPRINKLER INC ECON Total Paid for Credit Card Fee: $7.47 $7.47 FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $160.00 $160.00 7/25/19 WEB3935 CREDIT ORNNELL FIRE SPRINKLER INC ECON FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $240.00 $240.00 7/25/19 WEB3935 CREDIT ORNNELL FIRE SPRINKLER INC ECON Total Paid for FIRE FEES: $400.00 $400.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 7/25/19 WEB3935 CREDIT ORNNELL FIRE SPRINKLER INC ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/25/19 WEB3935 CREDIT ORNNELL FIRE SPRINKLER INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$422.47 $422.47 Printed: Tuesday, February 14, 2023 12:16:08 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0108 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 7/25/2019 EtrakitContractor 1ST SUBMITTAL - CUT SHEETS THE GYM TI MATERIAL DATA SHEETS.pdf 1 DOC 7/25/2019 EtrakitContractor 1ST SUBMITTAL - PLAN SET THE GYM TI PIPING FP- 1.pdf 1 BOND INFORMATION SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 8/26/2019 8/26/2019 APPROVED 909-222-0031 - Brandon FIRE FINAL**KHET 8/26/2019 8/26/2019 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) ARMANDO MAGALLON 7/25/2019 7/26/2019 8/15/2019 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 7/25/2019 8/8/2019 8/6/2019 APPROVED E-STAMPED PLANS, LETTER OF CONDITIONS AND JOB CARD IS IN ATTACHMENTS 1ST BLDG NS (1 WK)JAKE FUSON 7/26/2019 8/2/2019 8/12/2019 READY FOR APPROVAL - CONDS APPLICANT SUBMITTED FIRE SPRINKLER PLANS BUT NO T.I HAS BEEN SUBMITTED TO THE BUILDING DEPARTMENT. THIS REVIEW IS TO VERIFY WHETHER A BUILDING PERMIT IS REQUIRED. IF ANY WORK REQUIRING A BUILDING PERMIT PER CBC 105.1 IS PROPOSED OR HAS BEEN COMPLETED, APPROPRIATE PERMITS MUST BE OBTAINED. PARENT PROJECTS Printed: Tuesday, February 14, 2023 12:16:08 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0108 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/6/2019 KOHL HETRICK FSS2019-0108 - THE GYM - TI SPK - APPR.pdf FSS2019-0108 - THE GYM - TI SPK - APPR.pdf 1 DOC 8/6/2019 KOHL HETRICK FSS2019-0108 - APPROVED PLANS.pdf FSS2019-0108 - APPROVED PLANS.pdf 1 IMAGE 8/26/2019 KOHL HETRICK 08262019_014403_PM.J PG 08262019_014403_PM.J PG 0 Printed: Tuesday, February 14, 2023 12:16:08 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0108 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.02.21 Rev 19.1 Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 LPCB Approved: Certificate 096e/06 CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2” NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4” (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-1 Escutcheon.) MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.02.21 Rev 19.1 Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B. B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A ½” ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1” diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 21475M/B Protective Sprinkler Cap Wrench Flat MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.02.21 Rev 19.1 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C)100 °F (38 °C)Orange Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2” ratchet is required (not available from Viking) MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.02.21 Rev 19.1 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1 (UL) The Viking Microfast® Quick Response Pendent Sprinkler VK302 Maximum 175 PSI (12 Bar) WWP Base Part Number1 SIN Sprinkler Style Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria.) NPT BSP U.S.metric2 Inches mm cULus4 VdS LPCB 7 8 12979 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X A1 A1Z, B1Y D1Z, C1Y D1 -- 19780 VK302 Pendent 1/2” --5.6 80.6 2-1/4 58 ----------D3 21354 VK302 Pendent --15 mm 5.6 80.6 2-1/4 58 ----------D3 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06662B VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X ---------- 18021 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1X, B1Y A1 A1X, B1Y D1X, C1Y7 D1 -- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) Approved Finishes 1 - Brass, Chrome, White Polyester5,6, Black Polyes- ter5,6 2 - ENT5 3 - Chrome Approved Escutcheons X - Standard surface-mounted escutcheon or the Viking Micromatic® Model E-1 Recessed Escutcheon Y - Standard surface-mounted escutcheon or recessed with the Viking Micromatic® Model E-1, E-2, or E-3 Recessed Escutcheon Z - Standard surface-mounted escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-S0021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.02.21 Rev 19.1 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) The Viking Microfast® Quick Response Pendent Sprinkler VK302 Maximum 175 PSI (12 Bar) WWP Base Part Number1 SIN Sprinkler Style Thread Size Nominal K-Factor Overall Length FM Approvals3 (Refer also to Design Criteria.)NPT BSP U.S.metric2 Inches mm 12979 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06662B VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Approved Finishes 1 - Brass, Chrome, White Polyester4, and Black Polyester4 2 - ENT5 Approved Escutcheons X - Standard surface-mounted escutcheon or the Viking Micromatic® Model E-1 Recessed Escutcheon Y - Standard surface-mounted escutcheon or recessed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon Z - Standard surface-mounted escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion proofing for corrosive environments. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA Form No. F_033314 19.02.21 Rev 19.1 Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Figure 3: Sprinkler Dimensions with a Standard Escutcheon 1/2” (15 mm) NPT 2-1/4” (57 mm)1-3/4” (45 mm) Installed with a standard 1/8” surface-mounted escutcheon Ceiling Opening Size: 2-5/16” (59 mm) minimum 2-1/2” (64 mm) maximum 1-3/4” (45 mm)Max. 2-1/8” (54 mm) 1-1/8” (29 mm)Min. 2”” (51 mm)Max. 1-1/8” (29 mm)Min. 2-1/8” (54 mm) Ceiling Opening Size: 2-5/16” (59 mm) minimum 2-1/2” (64 mm) maximum Installed with a Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread-on Recessed Escutcheon Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-1 Escutcheon.) MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Page 1 of 4 Form No. F_052114 Rev 14.1 1. DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Chart 1 and Design Criteria on for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATASpecifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2” NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16” (56 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS- S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT platedOrdering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2” NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets:A. Six-head capacity: Part No. 01724A (available since 1971)B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATIONRefer to appropriate NFPA Installation Standards. Viking Technical Data may be found on The Viking Corporation’s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. (New Page) MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Page 2 of 4 Form No. F_052114 Rev 14.1 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast® Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C)100 °F (38 °C)Orange Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat-ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Figure 1: Standard Sprinkler Wrench 10896W/B Protective Sprinkler Cap Wrench Flat MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Page 3 of 4 Form No. F_052114 Rev 14.1 Approval Chart 1 (UL) Microfast® Quick Response Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals3 NPT BSP U.S.metric2 Inches mm cULus VdS LPCB 12978 VK300 1/2”15 mm 5.6 80.6 2-3/16 56 A1, B2 ------ Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Approved Finishes 1 - Brass, Chrome, White Polyester5,6, and Black Polyester5,6 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada 5 Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Page 4 of 4 Form No. F_052114 Rev 14.1 DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart 2 (FM) Microfast® Quick Response Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 (Refer also to Design Criteria below.)NPT BSP U.S.metric2 Inches mm 12978 VK300 1/2”15 mm 5.6 80.6 2-3/16 56 A1 Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Approved Finishes 1 - Brass, Chrome, White Polyester5, and Black Polyester5 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. 5 Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. (New Page) As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. Always ready to protect your most valuable assets. EDDYTHREAD 40 800.325.4467 sales@BullMooseIndustries.com BullMooseTube.com Bull Moose Fire Sprinkler Pipe Product Information Nominal Pipe Size (Inches)1"1-1/4" 1-1/2"2"2-1/2"3"4"6"8" O.D. (in)1.295 1.650 1.900 2.375 I.D. (in)1.083 1.418 1.654 2.123 Empty Weight (lb/ft)1.461 2.070 2.547 3.308 Water Filled Weight (lb/ft)1.860 2.754 3.468 4.842 C.R.R.1.00 1.00 1.00 1.00 Pieces per Lift 70 51 44 30 Lift Weight (lbs) 21' lengths 2,148 2,217 2,353 2,084 Lift Weight (lbs) 24' lengths 2,454 2,534 2,690 2,382 Lift Weight (lbs) 25' lengths 2,557 2,639 2,802 2,481EDDYTHREAD 40 EDDYTHREAD 40 ADVANTAGES: • UL listed (US & Canada) and FM approved • ASTM A135 and A795 Type E, Grade A Certified • Complies with NFPA-13, 13R and 14 • Industry-leading hydraulic characteristics • CRR of 1.0 and greater • All pipe NDT weld tested OTHER BENEFITS/SERVICES: • We have the most stocking locations in the industry, for best delivery and availability • Plain end or roll groove • Eddy Guard II™ bacterial-resistant internal coating • Custom length options • Hot dipped galvanization • Reddi-Pipe® red or black pipe eliminates field painting • Compatible for use in wet, dry, preaction and deluge sprinkler systems • The only maker with EPDs (to help earn LEED points).Exclusive maker of Reddi-Pipe® RED OR BLACK PAINTED PIPE. Size Range:3/8"-16 & 1/2"-13 rod Material:Malleable Iron (Stainless Steel Type 304 available) Standard Finish: Plain or Electro-Galvanized B3199RCT is DURA-COPPER™coated Function: Designed for attaching a hanger or support rod to beams, ceilings, or walls. Order By: Part number and finish. B3199R - Ceiling Flange B3199RCT - Ceiling Flange Dura-Copper Coated A (Rod or Pipe Thread) Hanger Rod or Pipe Not Included B Overall Height B 27/8" (73.0) 2" (50.8) 13/8" (34.9) For 1/4" Flat Head Machine Screws or Wood Screws Part No.Thread Size B Design Load Approx. Wt./100 A in. (mm)Lbs. (kN)Lbs. (kg) B3199R-3/8 B3199RCT-3/8 3/8"-16 7/16"(11.1)180 (.80)13 (5.9) B3199R-1/2 B3199RCT-1/2 1/2"-13 1/2"(12.7)180 (.80)17 (7.7) Part No. Pipe Size ABCHole Dia. D Thread Size Design Load Approx. Wt./100 in. (mm) in. (mm) in. (mm) in. (mm) in. (mm)E Lbs. (kN) Lbs. (kg) 78-3/8 1/2" - 2”(15 - 60)3"(76.2)21/8"(54.0)11/8"(28.6)5/16"(7.9)3/8"-16 150 (0.67)15 (6.8) --Consult Factory For Data Upper AttachmentsSize Range:3/8"-16 rod Material:Pre-Galvanized Steel Function:Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals:Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Additionally, UL has listed the Fig. 78 with fasteners as shown in the table below. Finish:Plain. Contact customer service for alternative finishes and materials. Order By:Part number, rod size and finish US Patent #5,702,077 UL Listed Fastener Table Pipe Size Qty Fastener Type Material 1/2" - 2" 2 #14 x 1 1/4" A-point hex-washer-head sheet metal screw Wood 21/2" - 4" 2 1/4" x 11/2" wood screws*Wood 1/2" - 2" 2 1/4" x 1" tek screws Metal (18 gauge) 1/2" - 2" 2 #14 x 1 1/4" A-point hex-washer-head sheet metal screw Wood 1/2" - 2" 2 #14 x 2" A-point-hex-washer-head sheet metal screw Wood thru 5/8" gyp board * No pre-drilling TOLCO™Fig. 78 - All Steel Ceiling Plate AB C D (2 Holes) E Upper Attachments 216 Eaton All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports B3199RCT B3199R www.tolco.com Fig. 25 - Surge Restrainer Size Range — One size fits 3/4” thru 2” pipe Material — Pre-Galvanized Steel Function — Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals — Underwriters’ Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish — Pre-Galvanized Order By — Figure number and TOLCO band hanger, size from 3/4” thru 2”. Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 Threaded AccessoriesThreaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) B3205L - Threaded Rod (right & left hand threads) ATR - All Threaded Rod 120” (3.05m)Lengths Fig. 99 - All Threaded Rod Cut To Length Size Range:3/8"-16 thru 3"-4 rod Material:Steel Function:Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature:750°F (399°C) Finish:Plain. Contact customer service for alternative finishes and materials. Order By:Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F (343°C)750°F (399°C) Part No.A in. (mm)Lbs. (kN)Lbs. (kN) B3205-3/8 x 'L'3/8"-16 2 1/2"(63.5)730 (3.25)572 (2.54) B3205-1/2 x 'L'1/2"-13 2 1/2"(63.5)1350 (6.00)1057 (4.70) B3205-5/8 x 'L'5/8"-11 2 1/2"(63.5)2160 (9.61)1692 (7.52) B3205-3/4 x 'L'3/4"-10 3"(76.2)3230 (14.37)2530 (11.25) B3205-7/8 x 'L'7/8"-9 3 1/2"(88.9)4480 (19.93)3508 (15.60) B3205-1 x 'L'1"-8 4"(101.6)5900 (26.24)4620 (20.55) B3205-11/8 x 'L'11/8"-7 4 1/2"(114.3)7450 (33.14)5830 (25.93) B3205-11/4 x 'L'11/4"-7 5"(127.0)9500 (42.25)7440 (33.09) B3205-11/2 x 'L'11/2"-6 6"(152.4)13800 (61.38)10807 (48.07) B3205-13/4 x 'L'13/4"-5 7"(177.8)18600 (82.73)14566 (64.79) B3205-2 x 'L'2"-41/2 8"(203.2)24600 (109.42)19625 (87.29) B3205-21/4 x 'L'21/4"-41/2 9"(228.6)32300 (143.67)25295 (112.51) B3205-21/2 x 'L'21/2"-4 10"(254.0)39800 (177.03)31169 (138.64) B3205-23/4 x 'L'23/4"-4 11"(279.4)49400 (219.73)38687 (172.08) B3205-3 x 'L'3"-4 12"(304.8)60100 (267.32)47066 (209.35) Part No. - Size x Length Threads Recommended Load Approx. Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN)Lbs. (kg) ATR 1/4” x 120 99- 1/4” x length 20 240 (1.07)12 (5.44) ATR 3/8” x 120 99-3/8” x length 16 730 (3.24)29 (13.15) ATR 1/2” x 120 99-1/2” x length 13 1350 (6.00)53 (24.04) ATR 5/8” x 120 99-5/8” x length 11 2160 (9.60)89 (40.37) ATR 3/4” x 120 99-3/4” x length 10 3230 (14.37)123 (55.79) ATR 7/8” x 120 99-7/8” x length 9 4480 (19.93)170 (77.11) ATR 1” x 120 99-1” x length 8 5900 (26.24)225 (102.06) ATR 11/8” x 120 99-11/8” x length 7 7450 (33.14)280 (127.01) ATR 11/4” x 120 99-11/4” x length 7 9500 (42.25)351 (159.21) ATR 11/2” x 120 99-11/2” x length 6 13800 (61.38)510 (231.33) 238 Eaton All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports TL TL Specify Length ‘L’ A Thread Size Size Range:3/8"-16 thru 11/2"-6 rod in 120” (3.05m)lengths or cut to length Material:Steel Maximum Temperature:750°F (399°C) Finish:Plain. Contact customer service for alternative finishes and materials. Order By:Part number, rod diameter and finish www.tolco.com Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4” and 11⁄4” Throat Openings Size Range — (Fig. 65 and Fig. 66) 3/8”, 1/2” and 5/8” rod Material — Carbon Steel with hardened cup point set screw and jam nut Function — Recommended for hanging from steel beam where flange thickness does not exceed 3/4” (Fig. 65) or 11⁄4” (Fig. 66). Features — All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8” rod will support 1/2” thru 4” pipe, 1/2” rod will support 1/2” thru 8” pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, rod size and finish Fig. 65 Patent #4,570,885 Dimensions • Weights Rod Size Max. Rec. Load Lbs.* Approx. Wt./100ABCDEF 3/8 1 3/16 3/4 1 7/16 1 610 28 1/2 1 1/2 3/4 1 9/16 1 1/4 1130 55 5/8 1 1/2 3/4 1 9/16 1 1/4 1130 55 *Max. loads for clamp with set screw in up or down position. Dimensions • Weights Rod Size Max. Rec. Load Lbs.* Approx. Wt./100ABCDEF 3/8 1 3/16 1 1/4 1 7/16 1 610 28 1/2 1 1/2 1 1/4 1 9/16 1 1/4 1130 55 5/8 1 1/2 1 1/4 1 9/16 1 1/4 1130 55 *Max. loads for clamp with set screw in up or down position. Fig. 65 Fig. 66 Component of State of California OSHPD Approved Seismic Restraints System COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 www.tolco.com Fig. 69 - Beam Clamp Retaining Strap Size Range — 3/8” thru 7/8” rod by 4” thru 16” length.* Material — Pre-Galvanized Steel Function — To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (2010) 9.3.7.1. Important Note — Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind such as a hex nut or the beveled locking slot on the TOLCO® Fig. 69R will provide a more secure reliable installation. Approvals — Underwriters’ Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Pre-Galvanized Order By — Figure number, type, length “B” and rod size being used with beam clamp Note — Minimum return on Strap: 1”. Dimensions • Weights Type Rod Size A Hole Size B 1 3/8 7/16 Specify 1/2 9/16 Specify 2 5/8 11/16 Specify 3/4 13/16 Specify 3 3/8 - 7/8 Specify Specify *Longer lengths are available, consult factory. COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org August 6, 2019 Ornnell Fire Sprinkler Inc. 22421 Barton Road, PMB #319 Grand Terrace, CA 92313 Re: Fire Sprinkler TI Plan Review – The Gym FSS2019-0108 / 46760 Commerce Ct, La Quinta, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. *Water-flow signal test may be performed during the Final Inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 46760 Commerce Ct, La Quinta PERMIT#: FSS2019-0108 DATE ISSUED: 8/6/2019 DESCRIPTION: TI FIRE SPRINKLER CONTRACTOR: ORNNELL FIRE SPRINKLER INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible dur ing the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.