FSS2019-0121ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT COSCO FIRE PROTECTION 4990 GREENCRAIG LN SAN DIEGO CA 92123 (858)444-2027 mlovely@coscofire.co m CONTRACTOR COSCO FIRE PROTECTION 4990 GREENCRAIG LN SAN DIEGO CA 92123 (858)444-2027 mlovely@coscofire.co m OWNER OFFICE MAX 79-190 HWY111 LA QUINTA CA 92253 (858)444-2027 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE KAYLI ALFORD 9/17/2019 9/17/2019 ISSUED AS OF 9/16 PER KOHL AND ATTACHED JOB CARD CONDITIONS Description: OFFICE MAX - 6753 Type: FIRE SPRINKLER (WEB)Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 9/13/2019 ECON Parcel No: 600390029 Site Address: 79190 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 9/16/2019 KHET Subdivision: PM 29351 Block: Lot: 11 Issued: 9/16/2019 KAL Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 9/23/2019 KHET Valuation: $5,743.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: ADD 2 UPRIGHT SPRINKLERS @ RECEIVING COUNTER FINANCIAL INFORMATION Printed: Tuesday, February 14, 2023 12:24:50 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0121 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 9/23/2019 9/23/2019 APPROVED FIRE FINAL**KHET 9/23/2019 9/23/2019 APPROVED REVIEWS RETURNED PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY Credit Card Fee 101-0000-43505 0 $7.47 $7.47 9/13/19 WEB4042 CREDIT COSCO FIRE PROTECTION INC ECON Total Paid for Credit Card Fee: $7.47 $7.47 FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $160.00 $160.00 9/13/19 WEB4042 CREDIT COSCO FIRE PROTECTION INC ECON FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $240.00 $240.00 9/13/19 WEB4042 CREDIT COSCO FIRE PROTECTION INC ECON Total Paid for FIRE FEES: $400.00 $400.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 9/13/19 WEB4042 CREDIT COSCO FIRE PROTECTION INC ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 9/13/19 WEB4042 CREDIT COSCO FIRE PROTECTION INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$422.47 $422.47 Printed: Tuesday, February 14, 2023 12:24:50 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0121 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/13/2019 EtrakitContractor FIRE SPRINKLER T.I PLAN 1908-1562 Office Max - 6753 La Quinta.pdf 1 DOC 9/13/2019 EtrakitContractor FIRE REVIEW APPLICATION Fire Review Application.pdf 1 DOC 9/13/2019 EtrakitContractor CUT SHEETS Material Submittal 001.pdf 1 DOC 9/16/2019 KOHL HETRICK 1ST SUBM - OFFICE MAX - SPK TI - APPROVED.pdf 1ST SUBM - OFFICE MAX - SPK TI - APPROVED.pdf 1 DOC 9/16/2019 KOHL HETRICK FSS2019-0121 - OFFICE MAX - TI SPK - COA and JOB CARD.pdf FSS2019-0121 - OFFICE MAX - TI SPK - COA and JOB CARD.pdf 1 BOND INFORMATION REVIEW TYPE REVIEWER SENT DATE DUE DATE DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 9/13/2019 9/16/2019 9/17/2019 COMPLETE 1ST FIRE (2 WK)FIRE BUCKET 9/13/2019 9/27/2019 9/16/2019 APPROVED SEE ATTACHMENTS Printed: Tuesday, February 14, 2023 12:24:50 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0121 EDCABOVEBALERRECEIVING COUNTERSPRINKLERRISERDRAWING TITLE PROJECT: CONTRACT WITH:DRAWN BY :SCALE :DATE :DESCRIPTIONNO. REVISIONS BYDATECRATOIONOCTTEETICTINCREER O ED F I F I PPRCLASSIFICATIONRONORTORAGCNFOSEELLI IN .NCEOTLSATSOFC O S ALICENSE NO.577621A C C-16L CIE SN JOB NO.SHEET NO.SPRINKLER HEAD LEGEND : APPROVALS BY: QUAN.SYMBOL K-FACT.ORIFICE FINISH PLATE FINISH HEAD TEMP. THIS SHEET TOTAL SPRINKLERS = S/N NPT LIC. # 577621 fire protection and life safety specialists SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE • ANCHORAGE www.coscofire.com4990 Greencraig Lane San Diego, California 92123 call (858) 444-2000•fax (858) 444-2056 SAN DIEGO OFFICE California C-16 OFFICE MAX - 6753 79-190 Hwy 111 La Quinta, CA 92253 Office Max 79-190 Hwy 111 La Quinta, CA 92253 Fire Sprinkler T.I9-11-19As NotedM. Jorgensen1908-1562FP-01VIKING Q.R UPRIGHT VK300 1/2"1/2"5.6K BRASS N/A 200°2 2 GENERAL NOTESSCOPE OF WORK1.PROVIDE DESIGN, MATERIALS, TOOLS, EQUIPMENT & LABOR TO ADD 2 UPRIGHT SPRINKLERS @RECEIVING COUNTER AREA.1.ALL MATERIALS & INSTALLATION OF THIS AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE INACCORDANCE WITH N.F.P.A #13 (2016 EDITION) & THE CITY OF LA QUINTA FIRE DEPT.2.ALL NEW MATERIALS INSTALLED SHALL BE NEW, UL LISTED AND/ OR F.M. "APPROVED" FOR FIREPROTECTION USE.3.ALL NEW 1"-2" PIPING SHALL BE GALVANIZED SCH.40 BLACK STEEL WITH THREADED AND MECHANICALTEE FITTINGS.4.FIRE SPRINKLER SPACING SHALL BE 225 SQ. FT. MAX AT LIGHT HAZARD AREA'S, AND 130 SQ.FT. MAX AT ORDINARY HAZARD AREA'S.5.WHERE STATIC & FLOWING PRESSURE EXCEEDS 100 PSI A HANGER SHALL BE REQUIRED FORARM-OVERS EXCEEDING 1'-0" IN LENGTH PER NFPA 9.2.3.5.2.16.ONE SPRINKLER HEAD PER 1" OUTLET UNLESS LOCATED IN DIFFERENT FIRE AREA.7.CONTRACTOR SHALL MAKE PIPING ABOVE SUSPENDED CEILINGS ACCESSIBLE TO PERSONNEL FORVISUAL INSPECTION AS A CONDITION OF FINAL APPROVAL.8.ALL NEW SYSTEMS SHALL BE HYDROSTATICALLY TESTED AT 200 PSI OR 50 PSI IN EXCESS OF THEMAXIMUM PRESSURE, WHEN THE MAXIMUM PRESSURE TO BE MAINTAINED IN EXCESS OF 150 PSI.HYDROSTATIC REQUIREMENTS FOR MODIFICATIONS TO A SYSTEM WITH 20 OR MORE HEADS &/OR WHERE MODIFICATIONS CANNOT BE ISOLATED, THE SYSTEM IS PERMITTED TO BE TESTED AT WORKING PRESSURE PER NFPA 13 SEC. 25.2.1.5 & 25.2.1.6.9.ALL VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER SYSTEMS ANDWATER-FLOW SWITCHES WILL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNITIN ACCORDANCE WITH CBC 903.410.THE AUTOMATIC SPRINKLER SYSTEM WILL BE MONITORED BY AND APPROVED SUPERVISING STATION INACCORDANCE WITH CBC 901.61.11.EACH FIRE DEPARTMENT CONNECTION MUST BE DESIGNATED BY A SIGN HAVING RAISED OR ENGRAVEDLETTERS AT LEAST 1 INCH IN HEIGHT.12.IT IS NOT "COSCO FIRE'S" INTENT FOR SPRINKLERS TO BE INSTALLED ALIGNED WITH CEILING FIXTURES.(I.E.: LIGHTS DIFFUSERS, FANS, ETC.)13.STRUCTURE IS STEEL.14.END OF BRANCH LINES RESTRAINT SHALL BE PROVIDED IN ACCORDANCE WITH N.F.P.A. 13, 2016SECTION 9.3.6. THE RESTRAINT IS NOT REQUIRED WHERE BRANCH LINES ARE SUPPORTED BYRODS LESS THAN 6" FROM TOP OF PIPE TO POINT OF ATTACHMENT TO THE BUILDINGSTRUCTURE. (FOR NEW WORK ONLY.)15.EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTION, SPRINKLERS ANDOTHER PENETRATIONS THROUGH THE CEILING TILE REQUIRE MINIMUM 2-INCH RINGS, SLEEVES,OR ADAPTERS THAT ALLOW A MINIMUM 1-INCH CEILING MOVEMENT IN ALL HORIZONTALDIRECTIONS. ALTERNATIVELY, A SWING JOINT SHALL BE PROVIDED AT THE TOP OF THESPRINKLER EXTENSION TO ACCOMMODATE THE 1-INCH MOVEMENT. (ASCE 13.5.6.2.2) (FORADDED OR RELOCATED SPRINKLERS ONLY)VICINITY MAPA-AEXISTING FIRESPRINKLERPIPEMECHANICAL TEENTSNNORTHFIRE SPRINKLER T.I. PLANNNORTH@ END OF BRANCHLINES & ARMOVERSSURGE RESTRAINER CLIPREQUIRED AT END OFBRANCHESPIPE15'-0"12'-0"MAXIMUM DISTANCE BETWEEN HANGERSNOMINAL PIPESIZE (in.)STEEL1"12'-0"1-1/4"2"15'-0"1-1/2"15'-0"3"4"6"8"15'-0"15'-0"15'-0"NTSSECTION VIEW -A-TOLCO FIG. 200PIPE RINGPIPETOLCO FIG. 100 ALL 3/8"THREAD RODTOLCO FIG 7538" SWIVELATTACHMENTNTSSSU SPRINKLER1" X 1/2" R.C.1" X 0-2 NIPPLETEENTSBRANCH LINE1" X 1/2" R.C.SSU SPRINKLERGUARDGUARDNTSAREA OF WORKTOLCO FIG. 71 ROD COUPLINGNUT AND FLATWASHER(top and bottom)TOLCO FIG. 200PIPE RINGPIPETOLCO FIG. 100 ALL 3/8"THREAD RODNTSNUT AND FLATWASHER(top and bottom)KEY PLANNNORTHSURGE RESTRAINER CLIP(N) DROP PIPING114" SCH.40D.I PLUGAUXILIARY DRAINSIGN(N) BRANCHLINENTSAPPROVEDRiverside County Fire DepartmentLa Quinta Office of the Fire MarshalBy:countyfire09/16/2019 4:11:06 PMThe approval of plans and specifications does notpermit the violation, deletion, omission or faultyinstallation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remainaccessible and exposed for inspection purposesuntil approved by the Fire Department.Kohl HetrickDigitally signed by Kohl HetrickDN: C=US, E=kohl.hetrick@fire.ca.gov, O=Riverside County Fire Department, OU=La Quinta Office of the Fire Marshal, CN=Kohl HetrickLocation: 78495 Calle Tampico, La Quinta, 92253Reason: I have reviewed this documentContact Info: 760-777-7074Date: 2019.07.23 08:23:01-07'00'FSS2019-0121 MATERIAL SUBMITTAL Date: 9-11-19 OFFICE MAX – 6753 79-190 HIGHWAY 111 LA QUINTA, CA 92253 JOB # 1908-1562 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted by: MATT JORGENSEN Los Angeles  San Francisco  Orange  Fresno  San Diego  Seattle San Diego Branch Office 4990 Greencraig Lane San Diego, CA 92123 (858) 444-2000 fax: 444-2056 CA Lic.: C-16 #577621 www.coscofire.com MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Page 1 of 4 Form No. F_052114 Rev 15.2 1. DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Chart 1 and Design Criteria on for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifi cations: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2” NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16” (56 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS- S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2” NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Viking Technical Data may be found on The Viking Corporation’s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Page 2 of 4 Form No. F_052114 Rev 15.2 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast® Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Figure 1: Standard Sprinkler Wrench 10896W/B Protective Sprinkler Cap Wrench Flat MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Page 3 of 4 Form No. F_052114 Rev 15.2 Approval Chart 1 (UL) Microfast® Quick Response Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals 3 NPT BSP U.S. metric 2 Inches mm cULus VdS LPCB NYC8 12978 VK300 1/2” 15 mm 5.6 80.6 2-3/16 56 A1, B2 -- --See footnote 7. -- NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06661B VK300 1/2” 15 mm 5.6 80.6 2-3/16 56 A1, B2 -- --See footnote 7. -- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Approved Finishes 1 - Brass, Chrome, White Polyester5,6, and Black Polyester5,6 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada 5 Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. 7 Meets New York City requirements, effective July 1, 2008 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Page 4 of 4 Form No. F_052114 Rev 15.2 DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart 2 (FM) Microfast® Quick Response Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 (Refer also to Design Criteria below.)NPT BSP U.S. metric 2 Inches mm 12978 VK300 1/2” 15 mm 5.6 80.6 2-3/16 56 A1, B2 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06661B VK300 1/2” 15 mm 5.6 80.6 2-3/16 56 A1, B2 Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Approved Finishes 1 - Brass, Chrome, White Polyester5, and Black Polyester5 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. 5 Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. Schedule-10/Schedule-40 – ABFII Fully Listed and FM Approved Sprinkler Pipe Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com • 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 ©2011 Atkore International, Inc. All Rights Reserved. STP-S5-3-1105 When you specify Allied Schedule-10/Schedule-40 – ABFII sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 – ABFII gives you the extra quality assurance you demand. Our Sch-10 (1¼”– 8”) pipe and Sch-40 (1”– 2½”) pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule-10/Schedule-40 – ABFII product can be “hot-dip” galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500” in diameter is coated with our new Antibacterial Formula, “ABFII”. In scientific laboratory tests, ABFII proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MIC) upon installation and the first 25 flushes of the fire sprinkler system.* American Made Able to meet “Buy American” requirement and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Schedule-10/Schedule-40 – ABFII pipe are in compliance with the following: ASTM A-135, Type E Grade A, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: • Welded Outlets • Hydrostatic Pressure • Side Wall Rupture Sch-40 – ABFII Specifications NPS Nominal I.D.Wt.Wt. (H20 Filled)CRR In; mm In; mm Lbs/Ft; kg/m Lbs/Ft; kg/m – 1”1.049 1.680 2.05 1 25 26.6 2.5 3.05 – 1¼”1.380 2.270 2.93 1 32 35.1 4.36 4.36 – 1½”1.610 2.720 3.61 1 40 40.9 4.0 5.37 – 2”2.067 3.650 5.13 1 50 52.5 5.4 7.63 – 2½”2.469 5.790 7.86 1 65 62.7 8.6 11.73 – Sch-10 – ABFII Specifications NPS Nominal I.D.Wt.Wt. (H20 Filled)CRR In; mm In; mm Lbs/Ft; kg/m Lbs/Ft; kg/m – 1¼”1.442 1.810 2.525 7.0955 32 36.6 2.7 3.75 – 1½”1.682 2.080 3.04 5.6570 40 42.7 3.1 4.52 – 2”2.157 2.640 4.22 4.5827 50 54.8 3.9 6.28 – 2½”2.635 3.530 5.89 3.5196 65 66.9 5.3 8.77 – 3”3.260 4.330 7.94 2.5550 75 82.8 6.4 11.82 – 4”4.260 5.610 11.78 1.6020 100 108.2 8.3 17.53 – 5”5.295 7.77 17.33 1.4874 125 134.5 11.56 25.80 – 6”6.357 9.290 23.03 1.0251 150 161.5 13.8 34.27 – 8”8.249 16.490 40.15 1.8365 200 209.5 24.5 59.75 – * See ABFII warranty Page 38 C.I. THREADED FITTINGS For fire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTM A126 CLASS B. DIMEN- SIONS CONFORM TO ANSI B16.4 CLASS 125 EXCEPT PLUGS CONFORM TO ASME B16.14. THREADS ARE NPT PER ANSI/ASME B1.20.1. CAST IRON 90 DEGREE ELBOW NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 CB90033 300 1.50 1.50 0.95 1 1/4 CB90044 300 1.75 1.75 1.34 1 1/2 CB90055 300 1.94 1.94 1.80 2 CB90066 300 2.25 2.25 2.90 2 1/2 DIMENSIONS CAST IRON STRAIGHT TEE NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 CT333 300 1.50 1.50 1.21 1 1/4 CT444 300 1.75 1.75 1.87 1 1/2 CT555 300 1.94 1.94 2.51 2 CT666 300 2.25 2.25 3.96 DIMENSIONS CAST IRON RED. COUPLING NOMINAL ITEM MAX. DIMENSION WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A PIECE 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 CAST IRON 45 DEGREE ELBOW NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 CB45033 300 1.12 1.12 0.84 1 1/4 CB45044 300 1.29 1.29 1.40 1 1/2 CB45055 300 1.43 1.43 1.80 2 CB45066 300 1.68 1.68 2.79 DIMENSIONS CAST IRON RED. 90 DEG. ELBOW NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1X1/2 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 1 1/4X1/2 CB90041 300 1.34 1.53 0.96 1 1/4X3/4 CB90042 300 1.45 1.62 1.13 1 1/4X1 CB90043 300 1.58 1.67 1.16 1 1/2X1 CB90053 300 1.65 1.80 1.51 DIMENSIONS 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3/4 CB90062 300 1.60 1.97 2.05 2X1 CB90063 300 1.73 2.02 2.10 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 CB90065 300 2.02 2.16 2.60 CAST IRON PLUGS NOMINAL ITEM MAX. DIMENSION WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A PIECE 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 300 1.25 0.28 1 1/4 CPL004 300 1.36 0.44 1 1/2 CPL005 300 1.45 0.62 2 CPL006 300 1.56 0.91 CB90077 300 2.70 2.70 4.75 2 1/2 CT777 300 2.70 2.70 6.45 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 Page 39 C.I. THREADED FITTINGS For fire protection services request submittal GRS 1.3 CAST IRON CROSS NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 CX033 300 1.50 1.50 1.54 1 1/4 CX044 300 1.75 1.75 2.40 1 1/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 DIMENSIONS CAST IRON REDUCING TEE NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B C PIECE 1X1X1/2 CT331 300 1.26 1.26 1.36 0.95 1X1X3/4 CT332 300 1.37 1.37 1.45 1.10 1X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1X3/4X1 CT323 300 1.50 1.45 1.50 1.18 1X1X1 1/4 CT334 300 1.67 1.67 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.80 1.65 1.73 1 1/4X1X1/2 CT431 300 1.34 1.26 1.53 1.17 1 1/4X1X3/4 CT432 300 1.45 1.37 1.62 1.38 1 1/4X1X1 CT433 300 1.58 1.50 1.57 1.47 1 1/4X1X1 1/4 CT434 300 1.75 1.67 1.75 1.80 1 1/4X1X1 1/2 CT435 300 1.88 1.80 1.82 2.05 1 1/4X1 1/4X1/2 CT441 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X3/4 CT442 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 1/4X1 1/4X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 1/4X1 1/4X2 CT446 300 2.10 2.10 1.90 2.55 1 1/2X1X1/2 CT531 300 1.41 1.34 1.66 1.41 1 1/2X1X3/4 CT532 300 1.52 1.37 1.75 1.65 1 1/2X1X1 CT533 300 1.65 1.50 1.80 1.65 1 1/2X1X1 1/4 CT534 300 1.82 1.67 1.88 2.00 1 1/2X1X1 1/2 CT535 300 1.94 1.80 1.94 2.30 1 1/2X1 1/4X1/2 CT541 300 1.41 1.34 1.66 1.58 1 1/2X1 1/4X3/4 CT542 300 1.52 1.45 1.75 1.72 1 1/2X1 1/4X1 CT543 300 1.65 1.58 1.80 1.85 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 CT665 300 2.02 2.02 2.16 3.72 DIMENSIONS 2x2x2 1/2 CT667 300 2.60 2.60 2.39 5.10 1 1/2x1 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 2.45 Victaulic Mechanical-T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a “holefinder” locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap II® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade “E” EPDM EPDM (Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade “T” nitrile Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are s ervices for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a l isting of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. 11.02_1 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N PATENTED 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS JOB/OWNER CONTRACTOR ENGINEER System No. __________________________Submitted By ________________________Spec Sect ____________ Para __________ Location ____________________________Date ________________________________Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K STYLES 920 AND 920N STYLE 920 CROSS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIPO DIMENSIONS GROOVED OUTLET W ZY V Size Style No. Max. Work Pressure@ Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg 2 × 1/2 (a) ¤ 920N 500 1.50 2.00 2.53 —1.61 5.35 2.75 3.1 —50 15 3450 38.1 51 64 41 136 70 1.5 3/4 (a) ¤ 920N 500 1.50 1.97 2.53 —1.61 5.35 2.75 3.1 —20 3450 38.1 50 64 41 136 70 1.5 1 (a) ¤920N 500 1.50 1.85 2.53 —1.61 5.35 2.75 3.0 —25 3450 38.1 47 64 41 136 70 1.4 1 1/4 (a) †¤920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 1/2 (a) †¤920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2 1/2 × 1/2 (a) §¤920N 500 1.50 2.21 2.74 —91.82 5.64 2.75 3.0 —65 15 3450 38.1 56 70 46 143 70 1.4 3/4 (a) §¤920N 500 1.50 2.18 2.74 —1.82 5.64 2.75 3.0 —20 3450 38.1 55 70 46 143 70 1.4 1 (a) §¤920N 500 1.50 2.06 2.74 —1.82 5.64 2.75 2.9 —25 3450 38.1 52 70 46 143 70 1.4 1 1/4 † (a) ¤920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 1 1/2 † (a) ¤920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 76.1 × 1/2 (a)920N 300 1.50 2.22 2.75 —2.25 6.46 3.18 3.9 —15 2065 38.1 56 70 57 164 81 1.8 3/4 (a)920N 300 1.50 2.19 2.75 —2.25 6.46 3.18 3.9 —20 2065 38.1 56 70 57 164 81 1.8 1 (a) 920N 300 1.50 2.07 2.75 —2.25 6.46 3.18 3.8 —25 2065 38.1 53 70 57 164 81 1.7 1 1/4 (a) ¤920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 1/2 (a) ¤920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 × 1/2 (a) ¤920N 500 1.50 2.52 3.05 —2.28 6.15 2.75 3.4 —80 15 3450 38.1 64 78 58 156 70 1.6 3/4 (a) ¤920N 500 1.50 2.49 3.05 —2.28 6.15 2.75 3.4 —20 3450 38.1 63 78 58 156 70 1.6 1 (a)920N 500 1.50 2.38 3.06 —2.28 6.15 2.75 3.3 —25 3450 38.1 61 78 58 156 70 1.6 1 1/4 (a) †¤920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32 (b)3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2 (a) †¤920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40 (b)3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) ¤920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3 1/2 × 2 920N 500 2.50 3.00 —3.75 2.44 6.72 3.88 —3.8 90 50 3450 63.5 76 95 62 171 99 1.8 TABLE CONTINUED ON PG. 3 FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. 11.02_2 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K DIMENSIONS GROOVED OUTLET W ZY V FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm Size Style No. Max. Work Pressure@ Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg TABLE CONTINUED FROM PAGE 2 4 × 1/2 (a) ¤920N 500 1.50 3.03 3.56 —2.69 7.01 2.75 3.7 —100 15 3450 38.1 77 90 68 178 70 1.8 3/4 (a) ¤920N 500 1.50 3.00 3.56 —2.69 7.01 2.75 3.7 —20 3450 38.1 76 90 68 178 70 1.8 1 (a) ¤920N 500 1.50 2.88 3.56 —2.69 7.01 2.75 3.6 —25 3450 38.1 73 90 68 178 70 1.8 1 1/4 (a) †¤920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32 (b)3450 44.5 78 96 102 68 178 76 1.9 1.8 1 1/2 (a) †¤920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40 (b)3450 50.8 83 102 102 68 178 83 2.0 1.9 2 (a) †¤920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 2 1/2 (a) †920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 —4.00 2.69 7.34 4.63 —6.4 3450 69.9 73 102 68 186 118 2.9 3 (a) †920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 108.0 × 1 1/4 (a)¤920N 500 1.75 3.08 3.78 —2.63 7.64 3.05 5.0 —32 3450 44.5 78 96 67 194 78 2.3 1 1/2 (a)¤920N 500 2.00 3.28 4.00 —2.63 7.64 3.25 5.0 —40 3450 50.8 83 102 67 194 83 2.3 2 (a)920N 500 2.50 3.25 4.00 —2.63 7.64 4.00 4.0 —50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 3450 69.9 73 102 102 67 194 109 3.6 3.5 3 (a)920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 5 × 1 1/2 (a) †920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2 (a) †920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 3450 63.5 102 121 121 80 246 111 3.7 3.6 2 1/2 (a) †920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm ¤920 500 2.75 3.75 —4.75 3.16 9.70 4.63 —8.0 3450 69.9 95 121 80 246 118 3.6 3 (a) †920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 133.0 × 2 920N 500 2.50 3.75 4.50 —3.17 8.00 3.88 8.0 —50 3450 63.5 95 114 81 203 99 3.6 3 920 500 3.50 3.81 5.00 —3.00 9.46 5.31 8.0 —80 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG. 4 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. 11.02_3 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K DIMENSIONS GROOVED OUTLET W ZY V FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm Size Style No. Max. Work Pressure@ Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg TABLE CONTINUED FROM PAGE 3 139.7 × 1 1/2 †920N 500 2.00 3.78 4.50 —3.30 8.23 3.25 7.0 —40 3450 50.8 96 114 84 209 83 3.2 2 †920N 500 2.50 3.75 4.50 —3.30 8.23 3.88 9.0 —50 3450 63.5 95 114 84 209 99 4.1 6 × 1 1/4 (a)920N 500 1.75 4.43 513 513 3.79 9.15 3.25 5.1 4.8 150 32 (b)3450 44.5 112 130 130 96 232 83 2.3 2.2 1 1/2 (a) †¤920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40 (b)3450 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) †¤920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 76.1 mm ¤920 500 2.75 4.15 —5.21 3.69 10.51 4.63 —8.4 3450 69.9 105 132 94 267 118 3.8 3 (a) †920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4 (a) †¤920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 159.0 × 1 1/2 (a)920N 500 2.00 4.41 5.13 —3.63 9.40 3.25 7.8 —40 3450 50.8 112 130 92 239 83 3.5 2 (a)920N 500 2.50 4.38 5.13 —3.63 9.40 3.88 8.0 —50 3450 63.5 111 130 92 239 99 3.6 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 108.0 mm 920 500 4.50 4.45 —5.38 3.63 9.40 6.12 —10.0 3450 114.3 113 137 92 239 155 4.5 4 920 500 4.50 3.81 5.75 —3.63 9.40 6.25 18.0 —100 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG. 5 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. 11.02_4 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K Size Style No. Max. Work Pressure@ Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg TABLE CONTINUED FROM PAGE 4 165.1 × 1 920N 500 1.50 3.88 4.56 —3.79 9.34 2.75 8.0 —25 3450 38.1 99 116 96 237 70 3.6 1 1/4 ¤920N 500 1.75 4.43 5.13 —3.79 9.34 3.25 8.4 —32 3450 44.5 113 130 96 237 83 3.8 1 1/2 (a) †¤920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2 (a) †920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 3 (a) † Ø 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 4 (a) †¤920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 × 2 (a) †920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 2 1/2 (a) †920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 76.1 mm ¤920 500 2.75 5.25 —6.25 4.81 12.42 4.56 —11.6 3450 69.9 133 159 122 316 116 5.3 3 (a) †¤920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 4 (a) †¤920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.` (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. DIMENSIONS GROOVED OUTLET W ZY V FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm 11.02_5 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. CV and Kv Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for CV /Kv Values: 1 2 Exaggerated for clarity OUTLET SIZE Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213, Sec. 16) (C = 120)ŧ FT CV/KV Values NOMINAL DIAMETER In/mm ACTUAL O.D. In/mm GROOVED THREADED GROOVED THREADED 1/2 0.840 -2 -11 15 21.3 9.4 3/4 1.050 -4 -16 20 26.7 13.7 1 1.315 -8 -21 25 33.7 1.8 1 1/4 1.660 5 1/2 6 50 48 32 42.7 42.9 41.1 1 1/2 1.900 11 11 53 53 40 98.3 45.4 45.4 2 2.375 9 10 1/2 112 104 50 60.3 96 89.1 2 1/2 2.875 20 12 1/2 119 150 65 73.0 102 128.5 3.000 16*-161 -76.1 mm 76.1 138.1 3 3.500 14 15 1/2 249 237 80 88.9 213.4 203.1 4 4.500 20 22 421 401 100 114.3 360.8 343.6 P = Q 2 Kv Where: Q = Flow ( ) P = P ressure (bar) Kv = Flow FactorQ = Kv x P m3 hr. ŧ Hazen-Williams coefficient of friction is 120.* Pipe with a wall thickness of 0.165in./4.2mm. 11.02_6 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Outlet Size Pipe Approval Agency Rated Working Pressures – psi/kPa Nominal Size Inches/mm Actual Outside Diameter Inches/mm Inches/mm Schedule UL ULC FM LPCB Vds (Style 920)(Style 920N) 21/2 - 6 2.875 - 6.625 All 10, 40 400 400 400 290 232 362 65 - 150 73.0 - 168.3 2755 2755 2755 1999 1599 2496 21/2 - 4 2.875 - 4.500 All DF 300 300 300 290 232 362 65 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 21/2 - 4 2.875 - 4.500 All SF 300 300 300 290 232 362 65 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 6 6.625 3, 4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30, 40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10, 40 400 ———145 —200 219.1 2755 1000 8 8.625 3,4 10 300 —250 —145 —200 219.1 2065 1724 1000 8 8.625 3,4 30, 40 300 —300 —145 —200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 8"/100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4"/100 mm, 5"/125 mm, 6"/150 mm and 8"/200 mm diameter pipe. The Style 931 comes with a 2 ½"/65 mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. 11.02_7 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. 11.02_K Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS For complete contact information, visit www.victaulic.com 11.02 1480 REV K UPDATED 4/2010 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. Pipe ClampsAll dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps Fire Protection Solutions38 Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Double Fastener Strap Side Mounted (B-Line B3183) Size Range:3/4" (20mm)thru 2" (50mm)CPVC pipe Material:Pre-Galvanized Steel Function:Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm)steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features:Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish:Pre-Galvanized Order By:Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. C A B B CPVC Max. Hanger Fastener Hex Approx. Pipe Size ABCSpacing Head Size Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m)in. (mm)Lbs. (kg) 24-3/4 3/4"(20)25/16"(58.7)15/32"(27.8)13/16"(30.2)51/2 (1.67)5/16"(7.9)9 (4.1) 24-1 1"(25)25/8"(66.7)15/16"(33.3)13/16"(30.2)6 (1.83)5/16"(7.9)9 (4.1) 24-11/4 11/4"(32)3"(76.2)11/2"(38.1)13/16"(30.2)61/2 (1.98)5/16"(7.9)11 (5.0) 24-11/2 11/2"(40)31/4"(82.5)15/8"(42.3)13/16"(30.2)7 (2.13)5/16"(7.9)12 (5.4) 24-2 2"(50)311/16"(93.7)127/32"(43.6)13/16"(30.2)8 (2.44)5/16"(7.9)15 (6.8) Fig. 25 - Surge Restrainer Size Range:— One size fits 3/4"(20mm)thru 2"(40mm)pipe. Material:— Pre-Galvanized Steel Function:— Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals:— Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL)and Canada (cUL). Finish:Pre-Galvanized Order By:Figure number and band hanger, size from 3/4"(20mm)thru 2"(40mm). Patent #5,344,108 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers 21Fire Protection Solutions Pipe Hangers Fig. 200 - “Trimline” Adjustable Band Hanger (B-Line Fig. B3170NF) Fig. 200F - “Trimline” Adjustable Band Hanger with Felt Lining (B-Line Fig. B3170NFF) Fig. 200C - “Trimline” Adjustable Band Hanger with Plastic Coated (B-Line Fig. B3170NFC) Fig. 200S - “Trimline” Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2” (15mm)thru 8” (200mm)pipe Material:Steel, Pre-Galvanized to G90 specifications Function:For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: •(1/2” (15mm)thru 2” (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. • (2 1/2” (65mm)thru 8” (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals:Underwriters Laboratories listed (1/2” (15mm)thru 8” (200mm)) in the USA (UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM)(3/4” (20mm)thru 8” (200mm)). Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature:650°F (343°C) Finish:Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By:Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. A B Fig. 200-1 to 200-2 Fig. 200-21/2 to 200-8 Pipe Size Rod Size ABApprox. Wt./100 Part No.in. (mm)in. (mm) in. (mm)lbs. (kg) 200-1/2 1/2"(15)3/8"-16 3 1/8"(79.4)25/8"(66.7)11 (5.0) 200-3/4 3/4"(20)3/8"-16 3 1/8"(79.4)21/2"(63.5)11 (5.0) 200-1 1"(25)3/8"-16 3 3/8"(85.7)25/8"(66.7)12 (5.5) 200-11/4 11/4"(32)3/8"-16 3 3/4"(94.0)27/8"(73.0)13 (5.9) 200-11/2 11/2"(40)3/8"-16 3 7/8"(98.4)27/8"(73.0)14 (6.4) 200-2 2"(50)3/8"-16 4 1/2"(114.3)3"(76.3)15 (6.9) 200-21/2 21/2"(65)3/8"-16 5 5/8"(142.9)41/8"(104.7)27 (12.3) 200-3 3"(75)3/8"-16 5 7/8"(149.1)4"(101.6)29 (13.3) 200-31/2 31/2"(90)3/8"-16 7 3/8"(187.3)51/4"(133.3)34 (15.6) 200-4 4"(100)3/8"-16 7 3/8"(187.3)5"(127.0)35 (16.0) 200-5 5"(125)1/2"-13 9 1/8"(231.8)61/4"(158.7)66 (30.2) 200-6 6"(150)1/2"-13 10 1/8"(257.2)63/4"(171.4)73 (33.4) 200-8 8"(200)1/2"-13 13 1/8"(333.4)83/4"(222.2)136 (62.3) Fig. 200-1/2. 200-3/4 Fig. 200C Fig. 200F Fig. 200 Fig. 200S Threaded AccessoriesB3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B3205L - Threaded Rod (right & left hand threads) ATR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range:3/8"-16 thru 3"-4 rod Material:Steel Function:Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature:750°F (399°C) Finish:Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By:Figure number, rod size, length and finish Size Range:3/8"-16 thru 11/2"-6 rod in 10’ (3.05m)lengths Material:Steel Maximum Temperature:750°F (399°C) Finish:Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By:Figure number, rod size, length and finish Note:Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. A Thread Size TL TL Specify Length Standard Design Load Thread Size Thread Length TL 650°F (343°C)750°F (399°C) Part No.A in. (mm)Lbs. (kN)Lbs. (kN) B3205-3/8 x 'L'3/8"-16 2 1/2"(63.5)730 (3.25)572 (2.54) B3205-1/2 x 'L'1/2"-13 2 1/2"(63.5)1350 (6.00)1057 (4.70) B3205-5/8 x 'L'5/8"-11 2 1/2"(63.5)2160 (9.61)1692 (7.52) B3205-3/4 x 'L'3/4"-10 3"(76.2)3230 (14.37)2530 (11.25) B3205-7/8 x 'L'7/8"-9 3 1/2"(88.9)4480 (19.93)3508 (15.60) Part No. Threads Recommended Load Approx. Wt./100 Ft. & Size Per Inch Lbs. (kN)Lbs. (kg) ATR 1/4” x ‘L’ 20 240 (1.07)12 (5.44) ATR 3/8” x ‘L’ 16 730 (3.24)29 (13.15) ATR 1/2” x ‘L’ 13 1350 (6.00)53 (24.04) ATR 5/8” x ‘L’ 11 2160 (9.60)89 (40.37) ATR 3/4” x ‘L’ 10 3230 (14.37)123 (55.79) ATR 7/8” x ‘L’9 4480 (19.93)170 (77.11) For larger sizes consult full line pipe hanger catalog. For larger sizes consult full line pipe hanger catalog. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Threaded Accessories Fire Protection Solutions94 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org September 16, 2019 Cosco Fire Protection 4990 Greencraig Ln San Diego, CA 92123 Re: TI Fire Sprinkler Plan Review – Office Max FSS2019-0121 / 79190 HIGHWAY 111, LA QUINTA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. *Water-flow signal test may be performed during the Final Inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79190 HWY 111 PERMIT#: FSS2019-0121 DATE ISSUED: 9/16/2019 DESCRIPTION: TI SPK – OFFICE MAX CONTRACTOR: COSCO FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.