Loading...
FSS2019-0144ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE JACK LIMA 12/5/2019 12/5/2019 REMOVED FIRE FEE OF $161.00 PER KAYLI ALFORD'S REQUEST. REINSPECTION FEE HAD ALREADY BEEN ENTERED AND PAID ON 11/13/2019. NOTE KAYLI ALFORD 11/4/2019 11/4/2019 APPROVED PER KOHL 11/4/19 NOTE KAYLI ALFORD 11/5/2019 11/5/2019 JOB CARD ISSUED TO ERIC FRANCO NOTE KAYLI ALFORD 11/13/2019 11/13/2019 REVISED PLAN SUBMITTAL TAKEN IN BY PERMIT TECH JLIMA 11/13/19 - ADDED 2 WK REVIEW FOR REVISION 1 TELEPHONE CALL KOHL HETRICK 11/27/2019 11/27/2019 Spoke with Javier and his Designer. Need them to swap out plans with ones that provide a 3-head calculation due to the spacing, located in the pockets created by beams. NFPA 13D Section 10.2.4. CONDITIONS Description: BR GROUP / BRES2018-0376 / 29 HEADS Type: FIRE SPRINKLER Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 10/16/2019 AMA Parcel No: 774265031 Site Address: 54765 AVENIDA JUAREZ LA QUINTA,CA 92253 Approved: 11/4/2019 KAL Subdivision: SANTA CARMELITA VALE LA QUINTA UNIT 25 Block: 275 Lot: 2 Issued: 11/5/2019 KAL Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 2/25/2020 crw Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Tuesday, February 07, 2023 2:54:37 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0144 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET BILL TO J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET OWNER BR GROUP 54765 AVENIDA JUAREZ LA QUINTA CA 92253 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 11/13/19 R55984 1777 CHECK J C FIRE PROTECTION JLIM FIRE PLAN REVISION SUBMITTALS 101-0000-42420 0 $161.00 $161.00 12/6/19 R56932 1790 CHECK J C FIRE PROTECTION AHI FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 10/16/19 R54944 1747 CHECK J C FIRE PROTECTION AMA FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 10/16/19 R54944 1747 CHECK J C FIRE PROTECTION AMA Total Paid for FIRE FEES: $725.00 $725.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 10/16/19 R54944 1747 CHECK J C FIRE PROTECTION AMA Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 10/16/19 R54944 1747 CHECK J C FIRE PROTECTION AMA Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 Printed: Tuesday, February 07, 2023 2:54:37 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0144 BOND INFORMATION INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 11/7/2019 11/7/2019 DISAPPROVE D NFPA 13D section 10.2 identifies the parameters for number of design sprinklers and them being located in/under beams. OH Rough inspection identified heads in all pockets and an increase in the number of heads in the compartment. Heads shall be installed as shown on approved plans in the beams, or a redesign with a minimum 3- head calculation will be required prior to Reinspection. OVERHEAD HYRO KHET 11/7/2019 11/7/2019 APPROVED OVERHEAD ROUGH PIPING KHET 12/6/2019 12/6/2019 APPROVED FIRE FINAL**KHET 2/25/2020 2/25/2020 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) ARMANDO MAGALLON 10/16/2019 10/17/2019 10/16/2019 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 10/16/2019 10/30/2019 11/4/2019 APPROVED 1ST FIRE (2 WK)FIRE BUCKET 11/13/2019 11/27/2019 12/5/2019 APPROVED REVISION 1 PLANS WERE SWITCHED FOR 12X12 3-HEAD CALC DUE TO BEAMS AND HEADS IN POCKETS PARENT PROJECTS TOTALS:$740.00 $740.00 Printed: Tuesday, February 07, 2023 2:54:37 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0144 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/5/2019 KAYLI ALFORD FIRE JOB CARD FIRE JOB CARD.doc DOC 11/7/2019 KOHL HETRICK FSS2019-0144 OH Rough Corr.pdf FSS2019-0144 OH Rough Corr.pdf 0 Printed: Tuesday, February 07, 2023 2:54:37 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0144 78-495 Calle Tampico, La Quinta CA 92253 Main: 760-777-7000 Direct: 760-777-7074 PAGE _____ OF _____ PERMIT/CASE#: NOTICE NO: FACILITY NAME: DATE: FACILITY ADDRESS: CONTACT: The items below are in violation of or shall meet additional requirements of one or more of the following:  CALIFORNIA FIRE CODE __________________  NFPA STD. ______________  CALIFORNIA BUILDING CODE _____________  CCR TITLE ______________  LA QUINTA MUNICIPAL CODE _____________  OTHER ________________ The listed violations/requirements shall be corrected immediately. A re-inspection will be conducted on or after ______________________________ 20____. FAILURE TO COMPLY MAY RESULT IN LEGAL ACTION AND/OR SIGNIFICANT DELAYS FOR APPROVAL. Received By: __________________________________ Signature: _______________________________________ Fire Inspector: _________________________________ Radio I.D.: _______________________________________ IF YOU HAVE ANY QUESTIONS OR NEED ADDITIONAL INFORMATION, PLEASE CALL 760-777-7074. 79485 Calle Tampico La Quinta, CA 92253 Main Number (760) 777-7158 Inspection Number  (760)777-7131 CITY OF LA QUINTA FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 54765 AVENIDA JUAREZ PERMIT# : FSS2019-0144 DATE ISSUED: 11/5/2019 DESCRIPTION: BR GROUP / BRES2019-0376 / 29 HEADS CONTRACTOR: J C FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: 79485 Calle Tampico La Quinta, CA 92253 Main Number (760) 777-7158 Inspection Number  (760)777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. The inspection hotline for the City of La Quinta is (760)777-7131 B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.