FSS2019-0145ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES Hetrick, Kohl@CALFIRE Mon 10/21/2019 3:19 PM nelson@smartfire.us; Armando Magallon <amagallon@laquintaca.gov>; Kayli Alford <kalford@laquintaca.gov>; Martha Mendez <mmendez@laquintaca.gov>; eric.thorn@usbldrs.com? CSLB 863196 - SUSPENDED.pdf 77 KB Nelson Moreno, You and any representatives of Smart Fire & Electrical Technologies INC (CSLB: 863196) are hereby ordered to Cease and Desist to continue any work on this referenced applied permit, due to the following: Description: FLOOR & DECOR / FIRE SPRINKLERS / BCOM2019-0016 Type: FIRE SPRINKLER Subtype: TENANT IMPROVEMENT Status: FINALED Applied: 10/16/2019 JLIM Parcel No: 600020028 Site Address: 79315 HIGHWAY 111 LA QUINTA,CA 92253 Approved: 11/20/2019 KHET Subdivision: PM 33588 Block: Lot: 2 Issued: 11/22/2019 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 4/28/2020 KHET Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: SMART FIRE & ELECTRICAL TECHNOLOGY INC (863196) SHOWS CSLB SUPENDED. 10/21/2019 - OBSERVED TENANT IMPROVEMENT WORK STARTED WITHOUT ISSUED PERMITS. *CEASE AND DESIST NOTICE ISSUED. **$100.00 CITATION WILL BE ISSUED. CSLB LICENSE IS RESTORED AND ACTIVE. CEASE AND DESIST IS STILL IN PLACE PENDING LA QUINTA CONSTRUCTION PERMIT. 1ST SUBMITTAL RESULTED IN CORRECTIONS. CEASE & DESIST IS LIFTED - PENDING RETRIEVAL OF APPROVED PLANS AND ISSUANCE OF JOB CARD. Printed: Tuesday, February 14, 2023 12:32:05 PM 1 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 E-MAIL KOHL HETRICK 10/21/2019 10/21/2019 1. CFC 105.1.1 Permits Required - … shall first make application to the fire code official and obtain the required permit. *It has been observed today (10/21/2019) that work as part of the applied permit has already been started, including by your own admission via a phone conversation on 10/21/2019. No Permit has been approved or issued to your or your agency as of yet. (Applied - 10/16/2019). 2. CA Business & Professions Code requires that a C-16 contractor maintain their license in good standing prior to starting and while performing contracted work. *CSLB 863196 shows as "License suspended for failure to comply with a bond payout." Additionally, an initial $100.00 Administrative Citation is being issued to Smart Fire & Electrical Technologies INC and will be sent to the currently shown address of 62751 Wandoo Rd, Palmdale, CA 93551. (LQMC 8.08.020) This Cease and Desist Notice will remain in effect until such a time that both items are addressed and cleared. Respectfully, KOHL HETRICK Fire Safety Specialist / Office of the Fire Marshal City of La Quinta CAL FIRE/Riverside County Fire Department Desk: 760-777-7074 | Mobile: 760-409-5109 Inspection Hotline: 760-777-7131 78495 Calle Tampico, La Quinta, CA 92253 kohl.hetrick@fire.ca.gov | www.rvcfire.org Sch: Mon-Thurs nLeadershipnCompetencenIntegritynSafetynCustomer Servicen The Office of the County Fire Marshal is committed to facilitating fire and life safety solutions by empowering its employees to serve our community through innovation and partnership. Printed: Tuesday, February 14, 2023 12:32:05 PM 2 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 E-MAIL KOHL HETRICK 10/21/2019 10/21/2019 E-MAIL KOHL HETRICK 10/23/2019 10/23/2019 Hetrick, Kohl@CALFIRE Wed 10/23/2019 1:15 PM eric.thorn@usbldrs.com? 2 attachments (4 MB) Download all Eric, I wanted to further identify an additional point of concern in regards to the condition of the existing fire sprinkler system. During the observation on Monday of the unpermitted work activity of Smart Fire & Electrical Technology Inc., it was observed of the several 2+ inch size fire sprinkler cross mains laying on the ground. These sections of existing pipe also present with signs of significant or concerning levels of interior pipe corrosion. Normally this would be addressed during normal system maintenance inspections that I do not believe have been done regularly nor recently at this location. Nevertheless, I am requiring that a NFPA 25 5-Year Inspection, Testing Maintenance Report be completed for this structure to correctly and adequately identify the overall systems condition. I do not expect a "pass" on this report at this time, but merely a thorough documentation of Comments and Deficiencies. This report should be completed by a CSLB licensed C-16 or SFM Licensed contractor. This report does require the interior inspection of various sections of the overall system, with specific concern at mains and cross- mains. There are several such contractors in the Coachella Valley area. They include, in no particular order and not limited to - Southwest Fire Pros, Shasta Fire Protection, Desert Fire, Kincaid, Johnson Controls, etc. Printed: Tuesday, February 14, 2023 12:32:05 PM 3 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 I will let you and your clients identify who will be ultimately responsible for addressing this situation (Floor & Décor or Property Manager). Please let me know if you have any questions. KOHL HETRICK Fire Safety Specialist / Office of the Fire Marshal City of La Quinta CAL FIRE/Riverside County Fire Department Desk: 760-777-7074 | Mobile: 760-409-5109 Inspection Hotline: 760-777-7131 78495 Calle Tampico, La Quinta, CA 92253 kohl.hetrick@fire.ca.gov | www.rvcfire.org Sch: Mon-Thurs nLeadershipnCompetencenIntegritynSafetynCustomer Servicen The Office of the County Fire Marshal is committed to facilitating fire and life safety solutions by empowering its employees to serve our community through innovation and partnership. Printed: Tuesday, February 14, 2023 12:32:05 PM 4 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 E-MAIL KOHL HETRICK 3/3/2020 3/3/2020 Mr. Nelson Moreno, Please find attached the formalized correction notice for the permit you hold for the Floor & Décor Tenant Improvement currently under Temporary Certificate of Occupancy operations. These items must be addressed in an orderly and complete manner prior to Fire Final can be provided. I believe this will clear up any confusion on what truly needs to be done and will satisfy La Quinta Office of the Fire Marshal (Authority Having Jurisdiction) and CCI - Floor & Decor contracted construction consultant. Please review and confirm receipt. Advise of any questions or concerns you may have. Below are my open lines of communication. Thank you, KOHL HETRICK NOTE KOHL HETRICK 11/4/2019 11/4/2019 Contractor spoke with Kayli and inquired of the status. They were advised that it was still pending review, but was expected sometime the following day (11/5). They were advised that they needed to pay the $100.00 citation fee for work without a permit and with a suspended CSLB license. Their CSLB license is now active and they paid the citation fee. The contractor was then inquiring the earliest to request an OH Rough Inspection. Kayli reminded them that they were not to be doing any work without an issued permit. The contractor advised that they were receiving pressure from the General Contractor to hurry up so that they could close up. Printed: Tuesday, February 14, 2023 12:32:05 PM 5 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 NOTE KOHL HETRICK 2/5/2020 2/5/2020 FACILITY IS TO BE PLACED ON FIRE WATCH FOR 24-HOURS A DAY, MULTIPLE CONSECUTIVE DAYS DUE TO THE WATER DISTRICT AND FIRE SPRINKLER CONTRACTOR CHANGING OUT THE BACKFLOW DEVICE AND FDC. THE FIRE SPRINKLER CONTRACTOR DOES NOT HAVE ALL OF THE PARTS AND THEREFORE THE FIRE SPRINKLER SYSTEM WILL BE OUT OF SERVICE DURING THIS TIME. STARTING AT 0700 ON 2/6/2020. AN EXPERIENCED SECURITY COMPANY IS BEING REQUIRED TO PROVIDE THE STAFFING OF THE FIRE WATCH PROGRAM. LOGS SHALL BE EMAILED DAILY. NOTE KOHL HETRICK 2/28/2020 2/28/2020 Observed Smart Fire crew adding heads and adjusting the spacing in a large area on the north interior side of the store. Not included in approved permit scope. Requested proof of Fire Sprinkler Fitter Certification. 3 crew members will not able to provide. Later the C-16 Contractor arrived and was not able to provide appropriate Fire Sprinkler Fitter Certification either. $200 (2nd violation incident) administrative citation was issued on account of performing fire sprinkler system improvements outside of scope of approved permit and plans. Continuing investigation and research into how to handle the work being performed by persons not appropriately certified Per CCR Title 19 Chapter 5.5. PLAN CHECK PICKED UP AARON HICKSON 11/6/2019 11/6/2019 NELSON MORENO PICKED UP CORRECTIONS PLAN CHECK SUBMITTAL RECEIVED KAYLI ALFORD 12/2/2019 12/2/2019 REVISION 1 PLANS SUBMITTED BY OSCAR MELARA PUBLIC COUNTER VISIT AARON HICKSON 12/10/2019 12/10/2019 CONTRACTOR PICKED UP REVISION PAID FEES AND REPRINTED JOB CARD TELEPHONE CALL KAYLI ALFORD 12/10/2019 12/10/2019 SPOKE TO NELSON MORENO & INFORMED HIM THAT REVISED PLANS ARE READY FOR PICKUP WITH PAYMENT OF OUTSTANDING FEES. Printed: Tuesday, February 14, 2023 12:32:05 PM 6 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SMART FIRE & ELECTRICAL TECHNOLOGY INC 2751 WANDOO ROAD PALMDALE CA 93551 (818)802-5777 BILL TO SMART FIRE & ELECTRICAL TECHNOLOGY INC 2751 WANDOO ROAD PALMDALE CA 93551 (818)802-5777 CONTRACTOR SMART FIRE & ELECTRICAL TECHNOLOGY INC 62751 WANDOO RD PALMDALE CA 93551 (818)802-5777 OWNER CENTRE AT LA QUINTA PARTNERS 3 HAMILTON LANDING NO 200 NOVATO CA 92253 (818)802-5777 TELEPHONE CALL KAYLI ALFORD 4/20/2020 4/20/2020 RECEIVED CALL FROM NELSON MORENO STATING HE WILL BE DOING A REVISED SUBMITTAL. ADDED REVISION FEE TO THE PERMIT SO THAT HE CAN PAY ONLINE VIA E TRAKIT AND HE WILL SUBMIT PLANS ONLINE. TELEPHONE CALL KOHL HETRICK 11/20/2019 11/20/2019 DISCUSSION WITH SMART FIRE (C-16) REVEALED THAT THE DRY SYSTEM IS NO LONGER GOING TO BE INSTALLED. ALL REFERENCE OF ON THE PLANS IS BEING RED-LINED TO APPROVE THE PLANS AND ISSUE JOB CARD. CONDITIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 4/27/20 WEB4977 CREDIT SMART FIRE & ELECTRICAL TECHNO ECON FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 4/27/20 WEB4977 CREDIT SMART FIRE & ELECTRICAL TECHNO ECON FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 12/10/19 R56994 9752 CHECK SMART FIRE & ELECTRICAL TECHNO AHI Printed: Tuesday, February 14, 2023 12:32:05 PM 7 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 11/26/2019 11/26/2019 PARTIALLY APPROVED Partial OH Rough of the office areas with drops approved only. *Okay to cover this area.**Immediate Concerns about the fire sprinkler system supplies and cutoff branch mains in the vacant tenant space. Reinspection required. Also require Underground Rough inspections for the DDCA and FDC changes. DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE PLAN REVISION SUBMITTALS 101-0000-42420 0 $161.00 $161.00 4/27/20 WEB4977 CREDIT SMART FIRE & ELECTRICAL TECHNO ECON FIRE PLAN REVISION SUBMITTALS 101-0000-42420 0 $161.00 $161.00 12/10/19 R56994 9752 CHECK SMART FIRE & ELECTRICAL TECHNO AHI FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS 101-0000-42420 0 $161.00 $161.00 10/16/19 MR804 9717 CHECK LEO FLORES - SMART FIRE & ELEC JLIM FIRE SPRINKLER SYSTEMS - TENANT IMPROVEMENT OVER 10 HEADS PC 101-0000-42420 0 $242.00 $242.00 10/16/19 MR804 9717 CHECK LEO FLORES - SMART FIRE & ELEC JLIM Total Paid for FIRE FEES: $1,208.00 $1,208.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 10/16/19 MR804 9717 CHECK LEO FLORES - SMART FIRE & ELEC JLIM Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 10/16/19 MR804 9717 CHECK LEO FLORES - SMART FIRE & ELEC JLIM Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$1,223.00 $1,223.00 Printed: Tuesday, February 14, 2023 12:32:05 PM 8 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 OVERHEAD ROUGH PIPING KHET 12/9/2019 12/9/2019 PARTIALLY APPROVED Confirming systems are charged for stock More inspection is still required to confirm all changes are completed and seismic bracing is provided. OVERHEAD ROUGH PIPING KHET 1/8/2020 1/8/2020 APPROVED All system connections were completed. Seismic bracing updated. Air Relief Valves were installed at locations approved on the plans - Inspection revealed that these are not the most elevated portions and will provide little benefit. RECOMMENDED to relocate to more appropriate location at the north end of the building where the mains are at a more elevated location. FIRE FINAL**KHET 1/8/2020 1/8/2020 DISAPPROVE D SEE ATTACHMENTS UG ROUGH PIPING KHET 1/8/2020 1/8/2020 NOT READY FIRE INSPECTOR KHET 2/28/2020 2/28/2020 DISAPPROVE D Inspection to identify remaining correction items to be addressed or even updated due to poor project management by contractor and ensuring appropriate inspections are provided for. Printed: Tuesday, February 14, 2023 12:32:05 PM 9 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 FIRE INSPECTOR KHET 2/28/2020 2/28/2020 DISAPPROVE D See Notes. CVWD Has installed above ground Double Check Backflow Assembly with non- indicating valves. Per DFM King, "okay" as water district is considering as part of their responsibility for maintenance. PIV monitoring has been disconnected. PIV assembly needs to be removed completely. Existing 4" rise-up to 2-snoot FDC is still present. Need to replace with 6" rise-up to 4-snoot FDC to be comparable with what was on the approved plans (4-snoot FDC direct to DCBA). Updated signage of Private Fire Main Equipment (DCBA and FDC) Fire Sprinkler Plans resubmitted as As-Builts. Spare Head boxes replenished with ALL sprinkler head types. Hydraulic Calc Plates updated. Contractor Record of Completion document provided. See Chronology for 3-3-2020 email and Attachments for Correction Order. UG ROUGH PIPING KHET 3/30/2020 3/30/2020 APPROVED PIV Removal / New FDC FIRE FINAL**KHET 4/28/2020 4/28/2020 APPROVED REVIEWS PARENT PROJECTS Printed: Tuesday, February 14, 2023 12:32:05 PM 10 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/24/2020 ARMANDO MAGALLON SCANNED PLAN SET (APPROVED 12-15-2019) PLAN SET (APPROVED).pdf 0 DOC 4/23/2020 EtrakitContractor FSS2019-0145 - REV 2 - HYD CALC AREA A-1 System 4 A-1 Entrance Area Floor and Decor Calculation.pdf 1 DOC 11/5/2019 KOHL HETRICK FSS2019-0145 FLOOR and DECOR - CORRECTIONS.docx FSS2019-0145 FLOOR and DECOR - CORRECTIONS.docx 1 DOC 1/9/2020 KOHL HETRICK FSS2019-0145 - FLOOR and DECOR - APPROVED.docx FSS2019-0145 - FLOOR and DECOR - APPROVED.docx 0 DOC 1/9/2020 KOHL HETRICK FSS2019-0145 - 1-8-20 - FIRE CORRECTIONS.pdf FSS2019-0145 - 1-8-20 - FIRE CORRECTIONS.pdf 0 DOC 3/3/2020 KOHL HETRICK FSS2019-0145 - 3-3-20 Corrections.pdf FSS2019-0145 - 3-3-20 Corrections.pdf 1 DOC 4/27/2020 KOHL HETRICK FSS2019-0145 - Rev. 2- As-Builts - Approved.pdf FSS2019-0145 - Rev. 2- As-Builts - Approved.pdf 1 BOND INFORMATION REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY)JACK LIMA 10/16/2019 10/17/2019 10/16/2019 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 10/16/2019 10/30/2019 11/5/2019 REVISIONS REQUIRED SEE ATTACHMENTS 2ND FIRE (1 WK)KOHL HETRICK 11/14/2019 11/21/2019 11/20/2019 APPROVED 1ST FIRE (1 WK)KOHL HETRICK 12/2/2019 12/9/2019 12/10/2019 APPROVED REVISION 1 1ST FIRE (2 WK)KOHL HETRICK 4/23/2020 4/30/2020 4/27/2020 APPROVED REVISION 2 / AS- BUILTS SEE ATTACHMENTS Printed: Tuesday, February 14, 2023 12:32:05 PM 11 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/28/2020 KOHL HETRICK Floor and Decor Sprinkler Certificate.pdf Floor and Decor Sprinkler Certificate.pdf 1 IMAGE 10/23/2019 KOHL HETRICK Sections of exisitng FS pipe (corroded) 1.IMG_0062.jpg 0 IMAGE 10/23/2019 KOHL HETRICK Sections of exisitng FS pipe (corroded) 2.IMG_0063.jpg 0 IMAGE 3/30/2020 KOHL HETRICK New 4 snoot FDC.JPG New 4 snoot FDC.JPG 0 IMAGE 3/30/2020 KOHL HETRICK Replacement UG pipe and FDC base.JPG Replacement UG pipe and FDC base.JPG 0 IMAGE 3/30/2020 KOHL HETRICK New Backflow with Nonindicating Valve CVWD.JPG New Backflow with Nonindicating Valve CVWD.JPG 0 IMAGE 3/30/2020 KOHL HETRICK 6 inch FDC riser.JPG 6 inch FDC riser.JPG 0 IMAGE 3/30/2020 KOHL HETRICK removed PIV and UG CV.JPG removed PIV and UG CV.JPG 0 IMAGE 3/30/2020 KOHL HETRICK UG replacement pipe 1.JPG UG replacement pipe 1.JPG 0 Printed: Tuesday, February 14, 2023 12:32:05 PM 12 of 12 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0145 REMOVEDFSS2019-0145 HG.5GF.5FE.515'-4"15'-4"STEEL BEAM CLAMP HANGERH-1STEEL BEAM CLAMP HANGERH-2 D.9ED.5D.2DC.9C.5CB.5BA.287.576.565.554.543.532.521.718² 15'-4"15'-4"STEEL BEAM CLAMP HANGERH-2141313.512.5 87.576.565.515'-4"15'-4"8141313.512.51191012 Smartfire & Elec. Tech., Inc. 2751 Wandoo Rd., N/A Palmdale, CA 93551 818-802-5777 Job Name : Floor & Decor A-1 Entrance Area Calculation Drawing : 19-64 Location : 79315 Highway 111, La Quinta, CA 92253 Remote Area : A-1 Contract : 19-64 Data File : SMARTFIRE-LA QUINTA FLOOR & DECOR Area 5.WXF Computer Programs by Hydratec Inc. Revision: 50.54.2 Smartfire & Elec. Tech., Inc. Page 1 Floor & Decor A-1 Entrance Area Calculation Date 4/13/2020 HYDRAULIC CALCULATIONS for Project name:La Quinta Floor & Decor System #4 Location:79315 Highway 111, La Quinta, CA 92253 Drawing no:19-64 Date:4/13/2020 Design Remote area number:A-1 Remote area location:Indicated On Plan (System #4) Occupancy classification:Extra Hazard Occupancy (Group I) Density:0.33 - Gpm/SqFt Area of application:+2,000 - SqFt Coverage per sprinkler:100 - SqFt Type of sprinklers calculated:Globe-GL8101 K=8.0 SSP No. of sprinklers calculated:20 In-rack demand:N/A - GPM Hose streams:500 - GPM Total water required (including hose streams):1,260.35 - GPM @ 56.78 - Psi Type of system:Grid System Volume of dry or preaction system:N/A - Gal Water supply information Date:2/4/19 Location:See Fire Flow Report Source:See Fire Flow Report Name of contractor:Smart Fire & Elec. Tech., Inc. Address:21001 Sherman Way #6 / / Canoga Park, CA 91303 Phone number:855-889-3811 Name of designer:B.V. Authority having jurisdiction:Riverside County Fire Department Notes: (Include peaking information or gridded systems here.)N/A Computer Programs by Hydratec Inc. Revision: 50.54.2 Smartfire & Elec. Tech., Inc. Page 2 Floor & Decor A-1 Entrance Area Calculation Date 4/13/2020 10 20 30 40 E 50 R 60 U 70 S 80 S 90 E 100 R 110 P 120 130 140 150 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW ( N ^ 1.85 ) City Water Supply: Demand: C1 C2 C1 - Static Pressure : 87.71 C2 - Residual Pressure: 18 C2 - Residual Flow : 4000 D1 - Elevation : 12.417 D2 - System Flow : 760.35 D2 - System Pressure : 56.775 Hose ( Demand ) : 500 D3 - System Demand : 1260.35 Safety Margin : 22.705 D1 D2 D3 Water Supply Curve C Computer Programs by Hydratec Inc. Revision: 50.54.2 Smartfire & Elec. Tech., Inc. Page 3 Floor & Decor A-1 Entrance Area Calculation Date 4/13/2020 Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used Summary Computer Programs by Hydratec Inc. Revision: 50.54.2 Smartfire & Elec. Tech., Inc. Page 4 Floor & Decor A-1 Entrance Area Calculation Date 4/13/2020 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 87.71 18 4000.0 79.48 1260.35 56.775 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 29.67 8 21.22 36.85 2 30.67 22.0 3 30.67 26.62 4 30.67 26.92 5 30.67 29.74 6 29.67 31.27 7 29.67 31.29 8 29.67 31.32 9 29.67 31.37 TOR 29.67 33.62 BOR 5.0 44.42 250.0 OH 5.0 44.67 UG -3.0 49.36 DC2 -3.0 51.6 DC1 -3.0 57.63 250.0 TEST 0.0 56.77 11 29.67 8 21.47 37.06 12 30.67 22.25 13 29.67 8 23.1 38.45 14 30.67 23.98 15 29.67 8 23.36 38.67 16 30.67 24.25 17 28.67 8 19.65 35.46 18 29.67 20.34 26 29.67 25.03 19 29.67 27.27 20 29.67 27.85 114A 29.67 30.28 114 0.0 44.11 22 0.0 44.11 23 28.67 8 17.02 33.0 24 29.67 17.57 28 29.67 20.03 25 28.67 8 24.1 39.28 27 28.67 8 19.36 35.2 29 29.67 8 21.92 37.46 30 30.67 22.73 31 30.67 26.61 32 30.67 26.91 33 30.67 29.73 34 29.67 8 22.17 37.67 35 30.67 23.0 36 29.67 8 22.32 37.8 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.2 Smartfire & Elec. Tech., Inc. Page 5 Floor & Decor A-1 Entrance Area Calculation Date 4/13/2020 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 37 30.67 23.16 38 29.67 8 22.58 38.01 39 30.67 23.43 40 29.67 8 21.85 37.4 41 30.67 22.66 42 30.67 26.66 43 30.67 26.97 44 30.67 29.78 45 29.67 8 22.1 37.61 46 30.67 22.92 47 29.67 8 22.49 37.94 48 30.67 23.33 49 29.67 8 22.74 38.15 50 30.67 23.6 60 29.67 8 25.67 40.53 61 30.67 26.68 62 30.67 29.59 63 30.67 30.5 64 29.67 8 26.88 41.48 65 30.67 27.95 66 30.67 29.49 67 29.67 8 25.87 40.69 68 30.67 26.89 69 30.67 29.66 70 30.67 30.58 71 29.67 8 27.1 41.65 72 30.67 28.19 73 30.67 29.56 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.54.2 Smartfire & Elec. Tech., Inc. Page 6 Floor & Decor A-1 Entrance Area Calculation Date 4/13/2020 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 29.67 8.00 36.85 1 E 2.0 1.000 120 21.223 to 0.0 2.000 -0.433 2 30.67 36.85 1.049 0.0 3.000 0.4033 1.210 Vel = 13.68 2 30.67 0.0 1 T 5.0 6.450 120 22.000 to 0.0 5.000 0.0 3 30.67 36.85 1.049 0.0 11.450 0.4031 4.616 Vel = 13.68 3 30.67 38.46 2.5 0.0 13.000 120 26.616 to 0.0 0.0 0.0 4 30.67 75.31 2.469 0.0 13.000 0.0234 0.304 Vel = 5.05 4 30.67 75.73 2.5 E 6.0 27.200 120 26.920 to 0.0 6.000 0.0 5 30.67 151.04 2.469 0.0 33.200 0.0848 2.815 Vel = 10.12 5 30.67 0.0 2.5 T 12.0 1.000 120 29.735 to 0.0 12.000 0.433 6 29.67 151.04 2.469 0.0 13.000 0.0848 1.103 Vel = 10.12 6 29.67 293.87 8 0.0 12.880 120 31.271 to 0.0 0.0 0.0 7 29.67 444.91 8.249 0.0 12.880 0.0018 0.023 Vel = 2.67 7 29.67 82.01 8 0.0 11.410 120 31.294 to 0.0 0.0 0.0 8 29.67 526.92 8.249 0.0 11.410 0.0024 0.027 Vel = 3.16 8 29.67 151.09 8 0.0 12.880 120 31.321 to 0.0 0.0 0.0 9 29.67 678.01 8.249 0.0 12.880 0.0038 0.049 Vel = 4.07 9 29.67 82.34 8 5E 105.706 368.920 120 31.370 to 0.0 105.706 0.0 TOR 29.67 760.35 8.249 0.0 474.626 0.0047 2.250 Vel = 4.56 TOR 29.67 0.0 8 0.0 24.670 120 33.620 to 0.0 0.0 10.685 BOR 5 760.35 8.249 0.0 24.670 0.0047 0.116 Vel = 4.56 BOR 5 H250 250.00 8 E 21.141 9.430 120 44.421 to 0.0 21.141 0.0 OH 5 1010.35 8.249 0.0 30.571 0.0080 0.245 Vel = 6.07 OH 5 0.0 6 2E 35.205 8.000 120 44.666 to 0.0 35.205 3.465 UG -3 1010.35 6.357 0.0 43.205 0.0285 1.232 Vel = 10.21 UG -3 0.0 8 3E 85.404 290.610 140 49.363 to 0.0 85.404 0.0 DC2 -3 1010.35 8.27 0.0 376.014 0.0060 2.239 Vel = 6.03 DC2 -3 0.0 8 0.0 4.020 140 51.602 to 0.0 0.0 6.000 * * Fixed Loss = 6 DC1 -3 1010.35 8.27 0.0 4.020 0.0060 0.024 Vel = 6.03 DC1 -3 H250 250.00 8 E 28.468 21.560 140 57.626 to 0.0 28.468 -1.299 TEST 0 1260.35 8.27 0.0 50.028 0.0090 0.448 Vel = 7.53 0.0 TEST 1260.35 56.775 K Factor = 167.27 11 29.67 8.00 37.06 1 E 2.0 1.000 120 21.466 to 0.0 2.000 -0.433 12 30.67 37.06 1.049 0.0 3.000 0.4073 1.222 Vel = 13.76 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.2 Smartfire & Elec. Tech., Inc. Page 7 Floor & Decor A-1 Entrance Area Calculation Date 4/13/2020 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 12 30.67 0.0 1 T 5.0 6.450 120 22.255 to 0.0 5.000 0.0 4 30.67 37.06 1.049 0.0 11.450 0.4074 4.665 Vel = 13.76 0.0 4 37.06 26.920 K Factor = 7.14 13 29.67 8.00 38.45 1 E 2.0 1.000 120 23.102 to 0.0 2.000 -0.433 14 30.67 38.45 1.049 0.0 3.000 0.4363 1.309 Vel = 14.27 14 30.67 0.0 1 T 5.0 1.050 120 23.978 to 0.0 5.000 0.0 3 30.67 38.45 1.049 0.0 6.050 0.4360 2.638 Vel = 14.27 0.0 3 38.45 26.616 K Factor = 7.45 15 29.67 8.00 38.67 1 E 2.0 1.000 120 23.365 to 0.0 2.000 -0.433 16 30.67 38.67 1.049 0.0 3.000 0.4407 1.322 Vel = 14.36 16 30.67 0.0 1 T 5.0 1.050 120 24.254 to 0.0 5.000 0.0 4 30.67 38.67 1.049 0.0 6.050 0.4407 2.666 Vel = 14.36 0.0 4 38.67 26.920 K Factor = 7.45 17 28.67 8.00 35.46 1 E 2.0 1.000 120 19.646 to 0.0 2.000 -0.433 18 29.67 35.46 1.049 0.0 3.000 0.3753 1.126 Vel = 13.16 18 29.67 0.0 1 T 5.0 7.500 120 20.339 to 0.0 5.000 0.0 26 29.67 35.46 1.049 0.0 12.500 0.3754 4.693 Vel = 13.16 26 29.67 39.28 1 0.0 1.500 120 25.032 to 0.0 0.0 0.0 19 29.67 74.74 1.049 0.0 1.500 1.4907 2.236 Vel = 27.75 19 29.67 0.0 2.5 T 12.0 13.000 120 27.268 to 0.0 12.000 0.0 20 29.67 74.74 2.469 0.0 25.000 0.0231 0.577 Vel = 5.01 20 29.67 68.19 2.5 T 16.474 27.250 120 27.845 to 0.0 16.474 0.0 114A 29.67 142.93 2.635 0.0 43.724 0.0558 2.439 Vel = 8.41 114A 29.67 0.0 2.5 T 16.474 1.000 120 30.284 to 0.0 16.474 12.850 114 0 142.93 2.635 0.0 17.474 0.0557 0.974 Vel = 8.41 114 0 0.0 8 0.0 9.170 120 44.108 to 0.0 0.0 0.0 22 0 142.93 8.249 0.0 9.170 0.0002 0.002 Vel = 0.86 22 0 150.94 8 0.0 12.920 120 44.110 to 0.0 0.0 -12.850 6 29.67 293.87 8.249 0.0 12.920 0.0009 0.011 Vel = 1.76 0.0 6 293.87 31.271 K Factor = 52.55 23 28.67 8.00 33.00 1 E 2.0 1.000 120 17.016 to 0.0 2.000 -0.433 24 29.67 33.0 1.049 0.0 3.000 0.3283 0.985 Vel = 12.25 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.2 Smartfire & Elec. Tech., Inc. Page 8 Floor & Decor A-1 Entrance Area Calculation Date 4/13/2020 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 24 29.67 0.0 1 0.0 7.500 120 17.568 to 0.0 0.0 0.0 28 29.670 33.0 1.049 0.0 7.500 0.3287 2.465 Vel = 12.25 28 29.670 35.20 1 T 6.217 1.500 120 20.033 to 0.0 6.217 0.0 20 29.67 68.2 1.097 0.0 7.717 1.0123 7.812 Vel = 23.15 0.0 20 68.20 27.845 K Factor = 12.92 25 28.67 8.00 39.28 1 E 2.0 1.000 120 24.104 to 0.0 2.000 -0.433 26 29.67 39.28 1.049 0.0 3.000 0.4537 1.361 Vel = 14.58 0.0 26 39.28 25.032 K Factor = 7.85 27 28.67 8.00 35.20 1 E 2.0 1.000 120 19.356 to 0.0 2.000 -0.433 28 29.670 35.2 1.049 0.0 3.000 0.3700 1.110 Vel = 13.07 0.0 28 35.20 20.033 K Factor = 7.86 29 29.67 8.00 37.46 1 E 2.0 1.000 120 21.922 to 0.0 2.000 -0.433 30 30.67 37.46 1.049 0.0 3.000 0.4153 1.246 Vel = 13.91 30 30.67 0.0 1 T 5.0 4.330 120 22.735 to 0.0 5.000 0.0 31 30.67 37.46 1.049 0.0 9.330 0.4154 3.876 Vel = 13.91 31 30.67 37.80 2.5 0.0 13.000 120 26.611 to 0.0 0.0 0.0 32 30.67 75.26 2.469 0.0 13.000 0.0233 0.303 Vel = 5.04 32 30.67 75.68 2.5 E 6.0 27.200 120 26.914 to 0.0 6.000 0.0 33 30.67 150.94 2.469 0.0 33.200 0.0847 2.812 Vel = 10.11 33 30.67 0.0 2.5 T 12.0 1.000 120 29.726 to 0.0 12.000 13.283 22 0 150.94 2.469 0.0 13.000 0.0847 1.101 Vel = 10.11 0.0 22 150.94 44.110 K Factor = 22.73 34 29.67 8.00 37.67 1 E 2.0 1.000 120 22.171 to 0.0 2.000 -0.433 35 30.67 37.67 1.049 0.0 3.000 0.4200 1.260 Vel = 13.98 35 30.67 0.0 1 T 5.0 4.330 120 22.998 to 0.0 5.000 0.0 32 30.67 37.67 1.049 0.0 9.330 0.4197 3.916 Vel = 13.98 0.0 32 37.67 26.914 K Factor = 7.26 36 29.67 8.00 37.80 1 E 2.0 1.000 120 22.324 to 0.0 2.000 -0.433 37 30.67 37.8 1.049 0.0 3.000 0.4227 1.268 Vel = 14.03 37 30.67 0.0 1 T 5.0 3.170 120 23.159 to 0.0 5.000 0.0 31 30.67 37.8 1.049 0.0 8.170 0.4225 3.452 Vel = 14.03 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.2 Smartfire & Elec. Tech., Inc. Page 9 Floor & Decor A-1 Entrance Area Calculation Date 4/13/2020 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 31 37.80 26.611 K Factor = 7.33 38 29.67 8.00 38.01 1 E 2.0 1.000 120 22.579 to 0.0 2.000 -0.433 39 30.67 38.01 1.049 0.0 3.000 0.4267 1.280 Vel = 14.11 39 30.67 0.0 1 T 5.0 3.170 120 23.426 to 0.0 5.000 0.0 32 30.67 38.01 1.049 0.0 8.170 0.4269 3.488 Vel = 14.11 0.0 32 38.01 26.914 K Factor = 7.33 40 29.67 8.00 37.40 1 E 2.0 1.000 120 21.852 to 0.0 2.000 -0.433 41 30.67 37.4 1.049 0.0 3.000 0.4143 1.243 Vel = 13.88 41 30.67 0.0 1 T 5.0 4.660 120 22.662 to 0.0 5.000 0.0 42 30.67 37.4 1.049 0.0 9.660 0.4142 4.001 Vel = 13.88 42 30.67 37.93 2.5 0.0 13.000 120 26.663 to 0.0 0.0 0.0 43 30.67 75.33 2.469 0.0 13.000 0.0235 0.305 Vel = 5.05 43 30.67 75.76 2.5 E 6.0 27.200 120 26.968 to 0.0 6.000 0.0 44 30.67 151.09 2.469 0.0 33.200 0.0848 2.817 Vel = 10.12 44 30.67 0.0 2.5 T 12.0 1.000 120 29.785 to 0.0 12.000 0.433 8 29.67 151.09 2.469 0.0 13.000 0.0848 1.103 Vel = 10.12 0.0 8 151.09 31.321 K Factor = 27.00 45 29.67 8.00 37.61 1 E 2.0 1.000 120 22.101 to 0.0 2.000 -0.433 46 30.67 37.61 1.049 0.0 3.000 0.4187 1.256 Vel = 13.96 46 30.67 0.0 1 T 5.0 4.660 120 22.924 to 0.0 5.000 0.0 43 30.67 37.61 1.049 0.0 9.660 0.4186 4.044 Vel = 13.96 0.0 43 37.61 26.968 K Factor = 7.24 47 29.67 8.00 37.94 1 E 2.0 1.000 120 22.486 to 0.0 2.000 -0.433 48 30.67 37.94 1.049 0.0 3.000 0.4253 1.276 Vel = 14.08 48 30.67 0.0 1 T 5.0 2.840 120 23.329 to 0.0 5.000 0.0 42 30.67 37.94 1.049 0.0 7.840 0.4253 3.334 Vel = 14.08 0.0 42 37.94 26.663 K Factor = 7.35 49 29.67 8.00 38.15 1 E 2.0 1.000 120 22.742 to 0.0 2.000 -0.433 50 30.67 38.15 1.049 0.0 3.000 0.4297 1.289 Vel = 14.16 50 30.67 0.0 1 T 5.0 2.840 120 23.598 to 0.0 5.000 0.0 43 30.67 38.15 1.049 0.0 7.840 0.4298 3.370 Vel = 14.16 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.2 Smartfire & Elec. Tech., Inc. Page 10 Floor & Decor A-1 Entrance Area Calculation Date 4/13/2020 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 43 38.15 26.968 K Factor = 7.35 60 29.67 8.00 40.53 1 E 2.0 1.000 120 25.668 to 0.0 2.000 -0.433 61 30.67 40.53 1.049 0.0 3.000 0.4807 1.442 Vel = 15.05 61 30.67 0.0 1 T 5.0 1.070 120 26.677 to 0.0 5.000 0.0 62 30.67 40.53 1.049 0.0 6.070 0.4807 2.918 Vel = 15.05 62 30.67 41.48 2.5 E 6.0 27.200 120 29.595 to 0.0 6.000 0.0 63 30.67 82.01 2.469 0.0 33.200 0.0274 0.909 Vel = 5.50 63 30.67 0.0 2.5 T 12.0 1.000 120 30.504 to 0.0 12.000 0.433 7 29.67 82.01 2.469 0.0 13.000 0.0275 0.357 Vel = 5.50 0.0 7 82.01 31.294 K Factor = 14.66 64 29.67 8.00 41.48 1 E 2.0 1.000 120 26.882 to 0.0 2.000 -0.433 65 30.67 41.48 1.049 0.0 3.000 0.5017 1.505 Vel = 15.40 65 30.67 0.0 1 E 2.0 1.070 120 27.954 to 0.0 2.000 0.0 66 30.67 41.48 1.049 0.0 3.070 0.5016 1.540 Vel = 15.40 66 30.67 0.0 2.5 0.0 13.000 120 29.494 to 0.0 0.0 0.0 62 30.67 41.48 2.469 0.0 13.000 0.0078 0.101 Vel = 2.78 0.0 62 41.48 29.595 K Factor = 7.62 67 29.67 8.00 40.69 1 E 2.0 1.000 120 25.872 to 0.0 2.000 -0.433 68 30.67 40.69 1.049 0.0 3.000 0.4843 1.453 Vel = 15.11 68 30.67 0.0 1 T 5.0 0.720 120 26.892 to 0.0 5.000 0.0 69 30.67 40.69 1.049 0.0 5.720 0.4843 2.770 Vel = 15.11 69 30.67 41.65 2.5 E 6.0 27.200 120 29.662 to 0.0 6.000 0.0 70 30.67 82.34 2.469 0.0 33.200 0.0276 0.916 Vel = 5.52 70 30.67 0.0 2.5 T 12.0 1.000 120 30.578 to 0.0 12.000 0.433 9 29.67 82.34 2.469 0.0 13.000 0.0276 0.359 Vel = 5.52 0.0 9 82.34 31.370 K Factor = 14.70 71 29.67 8.00 41.65 1 E 2.0 1.000 120 27.102 to 0.0 2.000 -0.433 72 30.67 41.65 1.049 0.0 3.000 0.5053 1.516 Vel = 15.46 72 30.67 0.0 1 E 2.0 0.720 120 28.185 to 0.0 2.000 0.0 73 30.67 41.65 1.049 0.0 2.720 0.5055 1.375 Vel = 15.46 73 30.67 0.0 2.5 0.0 13.000 120 29.560 to 0.0 0.0 0.0 69 30.67 41.65 2.469 0.0 13.000 0.0078 0.102 Vel = 2.79 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.2 Smartfire & Elec. Tech., Inc. Page 11 Floor & Decor A-1 Entrance Area Calculation Date 4/13/2020 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 69 41.65 29.662 K Factor = 7.65 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.2 SYSTEMSACCE JYl'ANCE 13-273 Contractor 's Material and Test Certificate for Aboveground Pipi ng PROCE DU RE Upon co mp let ion of work , inspection and tests shall be made by the co ntractor's representat ive and witnessed by the property ow ner or their autho ri zed agent. All defe cts sha ll be correcled and syslem left in service before contracto r's personnel rina lly leave the job. A certificate sha ll be till ed out and signed by both rep resentatives. Copies sha ll be prepared for approving authorities , owners . and contractor. It is understood the owner's rep re sentative's signature in no way prejudices any cla im against contractor for fau lt y mate ri al, poor workmanship , or failu re to comply with approving authority's requi rements or loca l ordinances. Property name fJ --r >7 l'l/Jf',rry I Date t.;-gt· IJ.tJ Property add ress 7-<?J ,~ ('A -111 \' lo-. IJ1.1i"A IQ-CA · Accepted by ap proving au thorities (names) Address - Plans ~Yes 0No Insta llation conforms to accepted plans Equ ipment used is app roved 0'ves It no, explain deviations Has person in cha rge of lire equipment been instructed as ~es 0No to location of control va lves and ca re and maintem:mr.e ol this new equipment? If no, explain Instru ctions ~es 0No Have copies of the foll owing been left on the premises? 1. System components instructions 0No 2. Care and mainte nance inst ruct ions ~: QNo 3. NFPA25 -f.tJO 0Yes Location of Supplies bui ldings system Yea r of Orifice Te mperature Make Mod el manufactu re size Qua ntity rating '1¥/n ~-C.-9 "i: .., }'/fl' Sp rinklers (j,1,.~11 -1< )/,~ j1'141 - Pipe an d Type of pi pe &i_-,c,5_ fte~L fitti ngs Type of fittings rJIA-Maximu m time to operate Alarm Alarm device through test connection va lve or Type Make I Model Minutes Seconds fl ow I indicator I Drv va lve I Q.O.D. Make Model I Serial no. I Make I Model Serial no. I I l Time to tr ip Time water Alarm thro ugh test Wate r Ai r Trip point reached operated Dry pipe con necliona,b p ress ure pressure air pressu re test ou tle t 3 ,b properly operati ng Minutes Seconds DSi os i test osi Minutes Seconds Yes No Without r-J(~-O.O.D. Wit h Q.O.D. If no, ex plain © 2015 Nationa l Fi re Pro tection Association NFPA 13 (p. 1 of 3) a Measured from time in spector's test connection Is opened . b NFPA 13 on ly re quires the GO-second limitation in specific sections. FIGURE 25 .1 Contractor's Mate rial an d Test Certificate fo r Aboveground Piping. 2016 Edition 13--274 INSTA Ll .'\TTON O F SPRJ:-.:KLER SYSTE:\IS Operati on Li Pneumatic OElectric 0 Hydrauli cs Pipi ng supervi sed OYes I Detecting med ia supervised UYes 0No Doe s va lve operate from th e manu al trip, remote, or both conlrol stations? 0Yes 0No Deluge and Is th ere an accessible faci lity in each circu it for testing ? I If no , explain preaction DNo valves Does each circuit operat e Does each circuit operate Maximum ti me to tJ/ It Mak e Model supervision loss alarm? valve release? operate release Yes I No Yes I No Mi nutes I Seconds I I I Pressu re-Locati on I Make and I I I Re sidual pressure I reducing and floor model Setting Static pressure (flowing ) Flow rate va lve test I I I Inlet (psi) I Outlet (psi) I Inlet (psi) I Outlet (psi) J Flow (g pm) NIA Backflow device Indicate means used for forward flow test of backflow device: forward When means to test device was opened , was system How demand created? 0 Yes fl ow test Hydrostatic te sts shall be made at not less than 200 psi (13.8 bar) for 2 hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.3 bar) for 2 hours. Differential dry pipe valve clappers shall be left Test open during th e te st to prevent damage. All aboveground piping leakage shall be stopped. description E.n.e.umatic; Establi sh 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1 ½ psi (0.1 bar) In 24 hours. Test pressu re tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 11;~ psi (0.1 bar) in 24 hours. All piping hydrostatically te sted at p~ bar) for ~ hours Dry piping pneumatically te sted tf.'L ~s O No Equipment operates properly S:,/J ,J.,,o , Yes O No 1 11 no , state rea son Do you ce rtify as the spnnkler contractor that additives and co rrosive chemicals , sodium si licate or derivatives of sodium sili cate~, or other co rrosi ve chemical s were not used for testing systems or stopping leaks? No ""' Tests Drain I Re ading of gauge located near water ~-e~\ Sttj1~idual pressure with valve in test test supply test connection : --psi ( bar) connection open wide:--psi ( -bar) Underg round mains and lead•in connections to system risers flushed before connection made to sprinkler piping Veri fi ed by copy of th e Contractor's Materi al and Test OYes Other Explain Certificate for Underground Piping. O Yes Flushed by install er of underground sprinkler piping If powder-driv en fa ste ners are used in co ncrete, 1 11 no, explain ha s representa tive sample te sting been sat isfa ctorily co mpleted ? Blank testing Number used I Locati ons I Number removed gaskets Welding piping OYes O No II yes ... N/!i Do you certify as th e sprinkl er contractor th at weldin g pro cedures used co mplied wi th Oves ONo the minimum requirements of AWS 82. t , ASME Section IX Welding and Brazing Qualifications, or other applicable qualification sta ndard as re quired by the AH J? Do you certify that all welding was perform ed by we lders or welding operators Oves ONo Welding qualified in accordance with the min imum requiremenl s of AWS 82.1, ASME Secti on IX Welding and Brazing O ualilicalions, or other appli cable quali fication standard as required by the AHJ ? Do you certify th at the we lding was conducted in comphance with a documented quality co ntro l proced ure to ensu re that (1) all di scs are ret rieved ; (2) that openings in O ves ONo piping are smooth, that slag and other weldi ng residue are removed : (3) the in ternal diameters of piping are not penetrat ed; (4) completed we lds are fre e from cracks, incomplete fusion , su rf ace porosil y greater than 1/rn in . ( 1.6 mm) diameter, undercul deeper than the lesser of 25% of th e wa ll thickness or 1/32 in . (0.8 mm); and (5) co mpleted c1rcumfercnlial bult weld rein forcement does not exceed 1/.32 m. (2.4 mm)? © 2015 N ati onal Fire Protectio n Associatio n NFPA 13 (p . 2 ol 3) FIGURE 25.1 Cn11ti11ued 2016 Edition ~'YSTEMS ACCEPTANCE Cutouts (discs) Do you certify th at you have a control feature to ensure that all cu touts {discs) are ret rieved? Hyd ra ulic data nameplate Na meplate provided ~s Sprinkler contractor rem ove d all caps and straps? ~s 0No 0No Rema rks Date left in service with all co nt ro l va lves open Nam Signatures .sig ned) Additional ex pla nations an 0 20 15 National Fire Protec1 1on Assoc,a \l on FIG U RE 25 .1 Cu11t i11 11 ed If no, explain 13-27j efv:s 0No Q . Date NFPA 13 \P. 3 ol.l\ 78-495 Calle Tampico, La Quinta CA 92253 Main: 760-777-7000 Direct: 760-777-7074 PAGE _____ OF _____ PERMIT/CASE#: NOTICE NO: FACILITY NAME: DATE: FACILITY ADDRESS: CONTACT: The items below are in violation of or shall meet additional requirements of one or more of the following:  CALIFORNIA FIRE CODE __________________  NFPA STD. ______________  CALIFORNIA BUILDING CODE _____________  CCR TITLE ______________  LA QUINTA MUNICIPAL CODE _____________  OTHER ________________ The listed violations/requirements shall be corrected immediately. A re-inspection will be conducted on or after ______________________________ 20____. FAILURE TO COMPLY MAY RESULT IN LEGAL ACTION AND/OR SIGNIFICANT DELAYS FOR APPROVAL. Received By: __________________________________ Signature: _______________________________________ Fire Inspector: _________________________________ Radio I.D.: _______________________________________ IF YOU HAVE ANY QUESTIONS OR NEED ADDITIONAL INFORMATION, PLEASE CALL 760-777-7074. 78-495 Calle Tampico, La Quinta CA 92253 Main: 760-777-7000 Direct: 760-777-7074 PAGE _____ OF _____ PERMIT/CASE#: NOTICE NO: FACILITY NAME: DATE: FACILITY ADDRESS: CONTACT: The items below are in violation of or shall meet additional requirements of one or more of the following:  CALIFORNIA FIRE CODE __________________  NFPA STD. ______________  CALIFORNIA BUILDING CODE _____________  CCR TITLE ______________  LA QUINTA MUNICIPAL CODE _____________  OTHER ________________ The listed violations/requirements shall be corrected immediately. A re-inspection will be conducted on or after ______________________________ 20____. FAILURE TO COMPLY MAY RESULT IN LEGAL ACTION AND/OR SIGNIFICANT DELAYS FOR APPROVAL. Received By: __________________________________ Signature: _______________________________________ Fire Inspector: _________________________________ Radio I.D.: _______________________________________ IF YOU HAVE ANY QUESTIONS OR NEED ADDITIONAL INFORMATION, PLEASE CALL 760-777-7074. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org November 20, 2019 (Addressee) Re: TI Fire Sprinkler Plan Review – FLOOR & DECOR FSS2019-0145 / 79315 HIGHWAY 111, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. *Per a telephone conversation with Smart Fire on 11/20/2019, there will no longer be a dry system installation for any of the canopies. All notification of the dry system on the approved plans have been red- lined out. A clean “As-Builts” shall be provided singularly at time of final inspection. The following inspections/tests are required to be witnessed by the Office of the Fire Marshal staff: 1) Overhead Rough: All installed/relocated piping must be visible. 2) Final inspection: All trim is in place, 5-Year certification is current. *Water-flow signal test may be performed during the Final Inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org November 5, 2019 Smart Fire & Electrical Technology Inc 2751 Wando Road Palmdale, CA 93551 Re: TI Fire Sprinkler Plan Review – Floor & Decor FSS2019-0145 / 79315 HIGHWAY 111, LA QUINTA, CA92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and require the following corrections: 1. Provide manufacturer cut-sheets and specifications for the new “6” 4-way FDC. 2. Provide manufacturer cut-sheets and specifications for the new Dry System components. 3. Identify the method for seismic restraint in compliance with NFPA 13 Chapter 9 for the new 2.5” piping elements connecting to the new Dry System. 4. Overhead (OH) System note 2 advises that there will be (2) 2-1/2” Dry Pipe Risers, but only one is detailed on the plans (Sheet 3). Clarify. There does appear to be a separate existing canopy area with sprinkler protection. Does this already have a Dry Pipe System? 5. Clarify the Scope of Work description (3) “Splitting the fire sprinkler system(s) so that each riser & system feeds their own single tenant.” Plans do not give any further detail to this. 6. Riser Detail on Sheet 1 identifies 4-inch risers fed from 6-inch manifold assembly. Calcs show 6- inch risers and 8-inch manifold assembly. 7. Single head sprinkler drops located in suspended ceilings shall be provided with seismic escutcheons or other approved devices for restraint or seismic bonding. Provide details. 8. Provide a mock-up on the revised plans of the required Hydraulic Calculation Plate that is to be installed as part of the new Dry System riser and design area. This mock-up shall be in compliance with NFPA 25 Section 25.5.2 as amended by CFC Chapter 80. (Example has been provided). 9. As this work is covering a new occupant that includes High-Piled storage – provide a mock-up of the required General Information Sign in compliance with NFPA 13 Section 25.6.2. (Example has been provided). 10. The Hydraulic Calculations packet provided did not identify on the Summary Sheet what “system type, including the system volume with type of protections system indicated in the notes.” NFPA 13 Section 23.3.5.2 (12). 11. As there has already been witnessed signs of interior pipe corrosion in the existing portions of the system, it is recommended to install an Air Relief Vent in each of the separate fire sprinkler systems in compliance with NFPA 13 section 7.1.5. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist