FSS2019-0161ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES Description: DEWEY / FIRE SPRINKLERS / BRES2019-0122 Type: FIRE SPRINKLER Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 12/23/2019 JLIM Parcel No: 777200018 Site Address: 53488 VIA STRADA LA QUINTA,CA 92253 Approved: 2/4/2020 KHET Subdivision: TR 29894-2 Block: Lot: 266 Issued: 2/5/2020 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/5/2020 crw Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Tuesday, February 07, 2023 3:07:07 PM 1 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0161 E-MAIL KOHL HETRICK 4/27/2020 4/27/2020 Good morning Chuck, I attempted a Final Inspection with Jason on the above permit. In part due to the poor cell signal in LQ, we were unable to complete the inspection. I wanted to share some concerns that I had. I accessed the "As-Built" plans that you provided (dated 2/17/2020) and were uploaded to the permit on 4/15/2020. These plans did not appropriately capture the now 125-feet of piping distance between the .75" water meter and base of riser. This particular change was what identified as requiring a submittal of revisions being required at time of the Overhead Rough inspection on 2/7/2020. Please provide revised hydraulic calculations for this original concern. Also, at time of inspection, the riser gauge was showing a static pressure of 40 psi and main drain residual of 35 psi. The 7/26/2019 water supply information shows a static pressure of 63.20 psi. The 40 psi is far below the minimum pressure allowed by the 90% safety factor. *Jason advised that there was other contractor services (irrigation, plumbing) that may be running water. If you are able to supply the revised hydraulic calcs today (I don't need plans again, I can use the as-builts) - then we can see as early as tomorrow reinspecting (without additional fees) for this project. *The revised calcs were also supposed to account for the additional 90's added as noted on the as- builts. Please let me know what will work for you. CONDITIONS Printed: Tuesday, February 07, 2023 3:07:07 PM 2 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0161 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT CHARLES F BROWN FIRE PROTECTION DESIGN 21386 LILIUM COURT MORENO VALLEY CA 92557 (760)340-9800 CHUCK92234@AOL.CO M CONTRACTOR CHARLES F BROWN FIRE PROTECTION DESIGN 21386 LILIUM COURT MORENO VALLEY CA 92557 (760)340-9800 CHUCK92234@AOL.CO M OWNER PAUL DEWEY LA QUINTA CA 92247 (760)340-9800 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE PLAN REVISION SUBMITTALS 101-0000-42420 0 $161.00 $161.00 4/29/20 WEB5013 CREDIT CHARLES F BROWN FIRE PROTECTIO ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 12/23/19 R57385 5282 CHECK CHARLES F BROWN FIRE PROTECTIO JLIM FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 12/23/19 R57385 5282 CHECK CHARLES F BROWN FIRE PROTECTIO JLIM Total Paid for FIRE FEES: $564.00 $564.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 12/23/19 R57385 5282 CHECK CHARLES F BROWN FIRE PROTECTIO JLIM Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 12/23/19 R57385 5282 CHECK CHARLES F BROWN FIRE PROTECTIO JLIM Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$579.00 $579.00 Printed: Tuesday, February 07, 2023 3:07:07 PM 3 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0161 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/15/2020 KAYLI ALFORD DEWEY AS BUILTS LOT 266 53488 VIA STRADA WORKING PLAN1-23-20-FP-1.1.pdf DEWEY AS BUILTS LOT 266 53488 VIA STRADA WORKING PLAN1-23-20-FP-1.1.pdf 0 DOC 1/27/2020 KOHL HETRICK FSS2019-0161 - DEWEY RES - CORRECTIONS.pdf FSS2019-0161 - DEWEY RES - CORRECTIONS.pdf 0 BOND INFORMATION OVERHEAD ROUGH PIPING KHET 2/7/2020 2/7/2020 APPROVED See Notes Prior to final inspection, revisions are required to show 125-ft 1.25" supply and additional red-line changes and observations. OVERHEAD HYRO KHET 2/7/2020 2/7/2020 APPROVED FIRE FINAL**KHET 5/5/2020 5/5/2020 APPROVED WITH BUCKET TEST Static at riser = 64psi. Bucket test performed on second floor only. Observed a minimum 16gpm from each head while flowing 5gpm domestic. REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) JACK LIMA 12/23/2019 12/26/2019 12/26/2019 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 12/23/2019 1/13/2020 1/16/2020 REVISIONS REQUIRED ADDED ADDITIONAL TIME TO ACCOUNT FOR THE HOLIDAYS. 2ND FIRE (1 WK)KOHL HETRICK 1/23/2020 1/30/2020 2/4/2020 APPROVED 1ST FIRE (2 WK)KOHL HETRICK 4/28/2020 5/12/2020 4/29/2020 APPROVED- CONDITIONS REV 1 - BUCKET TEST REQUIRED PARENT PROJECTS Printed: Tuesday, February 07, 2023 3:07:07 PM 4 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0161 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 2/5/2020 KOHL HETRICK FSS2019-0161 - DEWEY RES - 2ND REVIEW - APPR.pdf FSS2019-0161 - DEWEY RES - 2ND REVIEW - APPR.pdf 0 DOC 2/7/2020 KOHL HETRICK OH Rough Red Lines.pdf OH Rough Red Lines.pdf 0 DOC 4/29/2020 KOHL HETRICK FSS2019-0161 - REVISION 1 PLANS and CALCS - APPR CONDITIONALLY.pdf FSS2019-0161 - REVISION 1 PLANS and CALCS - APPR CONDITIONALLY.pdf 1 Printed: Tuesday, February 07, 2023 3:07:07 PM 5 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2019-0161 APPROVALS AND CONDITIONSNO A.S. REQUIRED 2/17/2020 lot 266 53488 via strada< LESS THAN 55 SQ. FT.NO A. S.< LESS THAN 55 SQ. FT.NO A. S.< LESS THAN 55 SQ. FT.NO A. S.OPEN TO 2ND. FLR.OPEN TO 2ND. FLR.OPEN TO 2ND. FLR.SEE A.S. AT 2ND. FLR.1" UP TO 2ND. FLR.< LESS THAN 55 SQ. FT.NO A. S.FROM 2ND. FLR.First Floor Sprinkler PlanNORTHNO A.S. REQUIREDFROM 2ND. FLR.UP TO NODE 2Ax2 EXTRA 90'Sx3 EXTRA 90'Sx6 EXTRA 90'SUPRIGHT IN ATTIC ABOVE FAU.DN.22RSecond Floor Sprinkler Planlot 266 53488 via stradaOPEN TO 1ST. FLR.< LESS THAN 55 SQ. FT.NO A. S.< LESS THAN 55 SQ. FT.NO A. S.1" TO FIRST FLR GREAT ROOM FP-1.1SHEET TITLE: PIPING & DETAILSPROJECT:No. DATE DESCRIPTIONREVISIONS:VIKINGMODELSYMMAKEAUTOMATIC SPRINKLERSTYCOCONTRACTOR:FSS2019-0161 REV 1