Loading...
FSS2020-0013Description: MODERN STRUCTURES Type: FIRE SPRINKLER Parcel No: 766031018 Subdivision: TR 28189 Lot Sq Ft: 0 Valuation: $0.00 No. Buildings: 0 D� etails Subtype: RESIDENTIAL -CUSTOM Status: ISSUED HOMES Site Address: 79540 TOM FAZIO LN N LA QUINTA,CA 92253 Block: Lot:6 Building Sq Ft: 0 Occupancy Type: No. Stories: 0 Zoning: Construction Type No. Unites: 0 Applied: 1/21/2020 AHI Approved: 2/11/2020 KHET Issued: 2/25/2020 JLIM Finaled: Expired: 8/23/2020 JLIM 14 21 J Applied to Approved 1 Approved to Issued ADDITIONAL •• ffel Felt CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PUBLIC COUNTER VISIT JACK LIMA 2/25/2020 2/25/2020 PERMIT ISSUED TO MICHAEL CORDOVA. CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET OWNER MODERN STRUCTURES LLC PO BOX 1573 RANCHO CA 92270 MIRAGE Printed: Wednesday, February 26, 2020 9:17:26 AM 1 of 3 C SrsrEMS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE 101-0000-42421 0 $161.00 $161.00 1/21/20 R58468 1818 CHECK JC FIRE PROTECTION AHI FAMILY DETACHED FIRE SPRINKLER SYSTEMS - SINGLE 101-0000-42420 0 $242.00 $242.00 1/21/20 R58468 1818 CHECK JC FIRE PROTECTION AHI FAMILY DETACHED PC Total Paid for FIRE FEES: $403.00 $403.00 RECORDS 101-0000-42416 0 $10.00 $10.00 1/21/20 R58468 1818 CHECK JC FIRE PROTECTION AHI MANAGEMENT FEE Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 1/21/20 R58468 1818 CHECK JC FIRE PROTECTION AHI ENHANCEMENT FEE Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:•0 $418.00 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE OVERHEAD ROUGH KHET 2/27/2020 PIPING OVERHEAD HYRO KHET 2/27/2020 1. PARENT PROJECTS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED REVIEWS STATUS REMARKS NOTES DATE 1ST PERMIT TECH (1 AARON 1/21/2020 1/22/2020 1/22/2020 COMPLETE DAY) HICKSON KOHL 1/21/2020 2/4/2020 2/11/2020 APPROVED 1ST FIRE (2 WK) HETRICK Printed: Wednesday, February 26, 2020 9:17:26 AM 2 of 3 .0"iImp'401 YSTEMS Attachment Type l CREATED I OWNER DOC 1 2/11/2020 1 KOHL HETRICK DESCRIPTION FSS2020-0013- MODERN STRUCTURES - APPR.pdf PATHNAME FSS2020-0013- MODERN STRUCTURES - APPR.pdf SUBDIR f ETRAKIT ENABLED Printed: Wednesday, February 26, 2020 9:17:26 AM 3 of 3 cow-YSTEMS HARDENED HEX HEAD SELF HARDENED HEX HEAR SELF THREADING SCREW THREADING SCREW i DOUBLE FASTENER STRAP 1YRE SINGLE FASTENER STRAP TYPE HANGER HANGER TYPICAL HANGER DETAILS ALL HANGERS SHALL HE PER NFPA 130 & THE CDDE REQUIREMENTS OF THE LOCAL AUTHORITY. TABLE 4-5.2.2-1 MAXIMUM DISTANGE BETWEEN HANGERS (FT -IN NOMINAL PIPE 3/4 1 1 1/4 1 1/2 2 2 1/2 SIZE (IN) CPVC 5-6 6-0 5-6 7-0 8-0 9-0 MAXIMUM END LINE TABLE 1 SUPPORT SPACING DISTANCE SPRINKLER HEAD DROP ELBOW PINE SIZE inches SYSTEM PRESSURE less than 100 psi more than 100 psi 3/4 9 6 1 12 9 11/4 16 12 1 1 2-3 24 12 MAXIMUM INLINE TABLE 2 SUPPORT SPACING DISTANCE SPRINKLER HEAD DROP TEE PIPE SIZE inches SYSTEM PRESSURE less than 100 psi more than 100 psi 3/4 4 3 1 5 4 11/4 6 5 1 1 /2-3 7 7 SUPPORT SPACING AT SPRINKLERS 5LL IAULL 1 SEE TABLE 2 TINISHE D COUNG UL LISTED PIPE CLAMP USE ONLY UL U5T£D FA5TEh1ERS SPRINKLER SPACING MAXIMUM DISTANCE BETWEEN SPRINKLER IN ROOMS WITH ONE HEAD IS 18)i18 FEET (9 FEET OFF WALLS). MAXIMU4 DISTANCE BETWEEN SPRINKLERS IN RDOMS WITH MORE THAN ONE HEAD SS 18x16 FEET (8 FEET OFF WALLS). MAXIMUM SPACING OF Q.R- SPRINKLERS IN GARAGE IS 130 SQUARE FEET, SPRINKLERS SHAD_ BE LOCATED A MINIMUM OF B" FROM A WAIL (NFPA) INSTALLATION NOTES 1- ALL C£SLIINGS THROUGHOUT RESIDENCE ARE HORIZONTAL (EXCEK WHERE NOTED). 2. ELEVATIONS AND DIMENSIONS SHDINN ON THESE DLtAW1NGS ARE NOMINAL ACPik MEASUREMENTS MAY VARY AND SFLAI_L BE MODIFIF-D AS REQUIRED FOR FIELD CONDFTIOISIS. 3. PIPE LENGTHS SHOWN ARE CENTER TO CENTER. 4. INSULATION TO BE INSTALLED ABOVE ALL CPVC FIRE SPRINK FR NPING (13Y OTHERS) NEW 1-1/4' SPRINKLER R€SER/D( ESTIC SHUT OFF AND 6' ELECTRIC BELL 1-1/2" PVC U.G. WATER SUPPLY 85 F-T. FROM METER TO RISER 4 J 1' WATER METER (I ] WATER SUPPLY TO METER NEW INSPECTORS TEST VALVE: IN ACCESS PANEL CVWD SYSTEM DATA DATE OBSERVED = 08-13-2019 INLET PRESSURE = 69.26 OUTLET PRESSURE = 38.36 ADJUSTED OUTLET PRESSURE = 34.52 SPARE HEAD BOX WILL BE PROVIIIED WTH AT LEAST ONE (1) SPARE SPRINKLER HEAD OF EACH TYPE, SIZE AND ORIFICE INSTALLED IN THE SYSTEM. TOR TO FIRE SPI#�KLER SYSTEM 6' ELECTRIC BELL (REi7)� WRED TO FLOW SWITCH ----1 - ' /4" CPVC Pa PE PRESSURE GAUGE TRANSITIN F1T7ING r PRESSURE RELIEF, TEST do DRAIN VALVE (CRAIN TO ATMOSPHERE) I MOUNTING P05T5 PROVIDE I SPARE FLQ1iY SRArITCH FS1 SPRINKLER HEAD FOR ::g fi F52 EACH TYPE INSTALLED 9 I -RUBBER FACED I CHECK VALVE PRV I ' ACCESS PANEL DOMESTJC VALVE- 1—t/+" COPPER DOM COMBINATION CONTROL ViALVE— (AEOV►E GRADE) -1/2' PVC u,G. �� BUR COPPER 1-1/4" RISER DETAIL N.T.S. HYDRAULIC CALCULATION DATA IBASEQ ON WATER P RESSURE CF u 9.1) SOURCE TWO HEAL] CALCULATION (AREA 1); 26.2 GPM 2l_97 PSI BOTTOM OF RISER 0145 HFAD CALCULATION (AREA 2): — 17 Q GPM 23.9 1 PSI @ BOTTOM OF RISER +1; AREA I CALL DESJGN INFORMATION CALGULATkONARFA_ BA iI k Z P SPRINKLERS CALCULATED 1. HEAD AREA PER "EAD ..1.Riel8 HOSE WATERALLOWANCE 5 CPU SYSTEM DEMAND PSI AVAILAgL.E AT SOURCE 34.5 PSI REOUIREO AT XIJ FACE 27.8 GPM REQUIRED AT SOURCE 22.Q PSI @ B-O-RISER - - 23.8 GPM2 B_a.RiSER r— I 17.0 TO FSY -S A AREA PER HEAD ] x HOSE WATER ALLOWANCE 5 GPM SYSTEM DEMAND PSI AVAILABLE AT SOU POE 34-5 PSI fi QUIRED AT 50I.IRCE 28,8 GPM REQUIRED AT SOURCE 31.2 PSI* _B.O.RiSER 23-2 GPM + B4O.RISEfi _ 26.2 Ar CROSS SECTION SCALE: ' 3/16 1-0 SPRINKLERS SHALL BE LOCATED A MINIMUM OF 6" FROM A TALL FIRE SPRINKLER PIPING PLAN NFPA 13D ri A SCAM: 3P I6 = 1-0 2 a C. 4 GENERAL FIRE SPRINKLER NOTES 1. ALL DMISH, MATERIALS AND INSTAILLATION OF THE FFE SPRINIILFR SON SHALL Ia MPLY KITH NFPA 13D AND LA QUINTA FK CODE RFQUIREirMS, 2. THE SCOPE DF WORK FOR THIS PROJECT I5 THE INST&UTION OF FIRE SPRIIVI4Lr-t5 AT MEN SINGLE FAMILY RaDENCE (SEE PLANS). 3. ALI NEW M RHEAD PIPING SHALL BE BLA2MAWR CPC SPRINKLER PIPE AND FITTINGS JOINED WttH UANUFAMRCIR PRMAIDED M-MDMNG PROCESS. k ALL MATERLAL USED IN THE INSTALLATIDN OF THIS FIRE SPRkNKLER SYSTEM SHALL BE NEW AND OF CURRE W ISSUE• ALL MATERIAL SHALL BE APPRpIVEp EfYY UNDERWRtTM LABORATORIES (U.L) AND BE IN CONFORW4A U WITH THE MAST CURRENT ISSUE OF NFPA 13, 13D AND THE AiMIORRY HAVIINC JURISDICTION, a. ALL MIEN PIPING SHALL BE HYDR067AT1CaAL.LY TEMD AS REQUIRED E3Y AHJ. B ALL SPR NKLERS SHALL BE DESIGNED FM USE IN R£SIDFDTiAL OCCUPANCIES. 7. COATIONS AND DUDSIONS 5xOM ON THESE pF WINGS ARE NOMIWL ACTM 4FASU"f1+iT'S MAY VARY AND SI-I LL BE WODflED AS REQUIRED FOR RED CONDRIONS. S. SPRINKLERS SHALL BE PERMM TO BE OEAfTTED IN SiaALL CLOSETS WHERE THE AREA OF THE SPXE DOE'S NOT EXCEED 24 SO, FT. AND THE LW DIMENSION DDES NOT EXCEED 3 FM FIRE PROTECTION SYMBOLS SYMBOL DESCRIPTION NEW FIRE SPRINKLER {USER +W/ DOMESTIC SHUT OFF VALVE NEW PENDENT SPRINKLER (SEE SPRINKLER L E ENC) NEW PENDENT SPRINKLER (SEE SPRINKLER LEGEND) NEW PIPING (CUT ON JOB) PIPE HANGER LOCATIONS 6/110 VOLT ELECTRIC; BELL (MRM BY ELECT. CONTRACTOR) INSPECTORS IM VALVE 07-0 MIA)(. A.F.F. WITH 7/16 SMOOTH BORE, NON -CORROSIVE ORIFCE (TC DISCHARGE OUTSIDE OE BUILDLNG) XX HYDRAULIC CALCULATLON NODE (REFERENCE POINT) 09STRUCAON D A A ] (D — 19 Inches) B D or = 30 Inches MJNIMUM UiSTAMCE FROM EDGE MINIMUM DISTANCE FROM F-DGE Ht ti i SOklFIGE OF SOURCE TO ORDINARY OF SOURCE TO INTERMEDIATE TEMPERATURE SPRNKLER TEMPERATURESPgINKLER INCHES WCHIES SIQE OF OPEK OR 36 12 RECESSES} FIREPLACE FRONT CIF RECESSED FIREPLACE 60 36 SIDE OF CEILING— OR WALL —MOUNTED HOT 24 12 AIR DIFFUSERS FRONT OF WALL —MOUNTED HOT 36 iI9 AIR 011FUSERS LIGHT F XTLIRE 3 0W-250W LIGHT FIXTURE 250 W -- 499 W 12 6 XITCH N RANGE 18 9 LIGHTS, FANS AND DIFFUSER SMALL BE COORDINATED AROUND SPRINKLER HEADS TO AVOID OBSTRUCTIONS AND HEAT SOURCE DISTANCES IN ACCORDANCE WITH NFPA RECOMMENDATIONS MAINTAIN 36" MINIMUM FROM THE CENTER OF CEILING FANS & LIGHT FIXTURES THAT ARE OBSTRUCTIONS TO SPRI-NKLER DISCHARGE. NFPA13D AHJ USE ONLY APPROVAL RIvor0de Cbunty fire pa"ent Of r �-j :I�tt %� I� ��vak I;tdul , oad SUc-uilw0ung dim not Permly ukolaLian, dcilnon, dmi5slw or faulty Msmllanon of any regulr rn ixt5 of The 24 iar any t-=, Q7i fiatwe'S. nemaln acr_essibLe and exposed For inspecaan purpcses until approved by tkte iP re Departn-ent. <a Q LLJ O F W z F W ❑r LLJ k I Li LLj a,_ x w u7 0 0 r* or- LLJ Ld�N im 1 M�N 1.*44 a 00 7- 52 72 LjLdw z z z z • 1� � 0 z rn U' cc W (.) uu cc o Lu ILu CL C1 L 41 o L o I c 0 � 0 rn c Q c 0 LL n L LLJ 0 rjo Lu rr J Lu w 0 LL W Lu Ir WL z 0 LO Iti � 0 z 0 a+ n_ FIRE SPRINKI. ER' PIPING PLAN I REVISIONS A r\ AREA CALCULATIONS PER UNI LIVABLE 5.-525 GARAGE TOTAL SYSTEM AREA 4,031 PRESSURE AT SITE 08-27-19 59.26 PSI DESIGNER CM SCALE 3 16 = 1-0 CHECK BY FFM FILE NUMBER 2C.003 APPROVAL LA QIUINTA DATE 01--08-2020 DRAWING 140. FP Sheet 1 of i Sheets Molano, Angel ica@CALFI RE Subject: Location: Start: End: Recurrence: Meeting Status: Organizer: JAVIER 760-625-5908 FSS2020-0013 - THE QUARRY - OH SPRINKLER ROUGH/HYDRO 79540 TOM FAZIO LN Thu 2/27/2020 11:00 AM Thu 2/27/2020 12:00 PM (none) Meeting organizer Hetrick, Kohl@CALFIRE SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 1 1HD CALC.SDF JOB TITLE: AREA 1 1HD (18x18) (17 GPM) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW NODE PRESS. PRESS. @ TAG (PSI) (PSI) (GPM) M (N/A) 34.5 (N/A) AGGREGATE FLOW ANALYSIS: AVAIL. TOTAL REQ'D PRESS. @ DEMAND PRESS. (PSI) (GPM) (PSI) 34.5 22.0 27.5 TOTAL FLOW AT SOURCE 22.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 17.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) P1 11.8 K= 4.90 12.0 17.0 P2 11.8 - - - - 14.0 - - P3 11.8 - - - -- 14.0 - - - 1 12.2 - - - - 12.0 - - - 2 12.2 - - - - 13.8 - - 3 12.2 - - - - 13.8 - - - A 12.2 -- - - - 13.4 - - - B 13.2 - - - - 13.3 C 12.2 - - - - 13.8 - - - D 12.2 - - - - 14.2 - - - E 12.2 - - - - 14.9 - - - TOR 12.2 - - - - 15.1 FS1 4.0 - - - - 18.8 FS2 4.0 -- - - - 21.8 - - - BOR 0.5 - - - - 23.8 - - - DOM 0.5 HOSE STREAM 24.2 5.0 UG -3.0 - - - = 26.2 - - M -3.0 SOURCE 27.5 22.0 APPROVAL Riverside County Fire Department offke Fiv: Kohl He The allproval of plans and speutications does not nermit the violation, deletion, omission or faulty installation of any rNuirements of Title 24 or any Local Ordinances. Construction shall remain uzesslble and exposed for inspection purposes untP awrovt,d by the Fire Department. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 1 1HD CALC.SDF JOB TITLE: AREA 1 1HD (18xl8) (17 GPM) PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV, NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -17.0 1.101 PL 0.50 PF 0.2 Pi 11.8 4.9 12.0 17.0 5.7 150 FTG E PE -0.2 1 12.2 0.0 12.0 0.0 0.050 TL 3.00 PV Pipe: 2 0.0 1.101 PL 0.50 PF 0.0 P2 11.8 0.0 14.0 0.0 0.0 150 FTG E PE -0.2 2 12.2 0.0 13.8 0.0 0.000 TL 3.00 PV Pipe: 3 0.0 1.101 PL 0.50 PF 0.0 P3 11.8 0.0 14.0 0.0 0.0 150 FTG T PE -0.2 3 12.2 0.0 13.8 0.0 0.000 TL 6.50 PV Pipe: 4 -17.0 1.101 PL 18.25 PF 1.4 1 12.2 0.0 12.0 0.0 5.7 150 FTG ETR PE 0.0 A 12.2 0.0 13.4 0.0 0.050 TL 28.45 PV Pipe: 5 0.0 1.101 PL 9.25 PF 0.0 2 12.2 0.0 13.8 0.0 0.0 150 FTG R PE 0.0 3 12.2 0.0 13.8 0.0 0.000 TL 10.95 PV Pipe: 6 0.0 1.101 PL 0.50 PF 0.0 3 12.2 0.0 13.8 0.0 0.0 150 FTG T PE 0.0 C 12.2 0.0 13.8 0.0 0.000 TL 6.50 PV Pipe: 7 -4.0 1.101 PL 61.75 PF 0.3 A 12.2 0.0 13.4 0.0 1.4 150 FTG 2ET4R PE -0.4 B 13.2 0.0 13.3 0.0 0.004 TL 79.55 PV Pipe: 8 -4.0 1.101 PL 22.25 PF 0.1 B 13.2 0.0 13.3 0.0 1.4 150 FTG 2ET3R PE 0.4 C 12.2 0.0 13.8 0.0 0.004 TL 38.35 PV Pipe: 9 -4.0 1.101 PL 68.25 PF 0.3 C 12.2 0.0 13.8 0.0 1.4 150 FTG 4ET6R PE 0.0 D 12.2 0.0 14.2 0.0 0.004 TL 94.45 PV Pipe: 10 -13.0 1.101 PL 21.25 PF 0.8 A 12.2 0.0 13.4 0.0 4.4 150 FTG 2R PE 0.0 D 12.2 0.0 14.2 0.0 0.030 TL 24.65 PV Pipe: 11 -17.0 1.394 PL 33.75 PF 0.7 D 12.2 0.0 14.2 0.0 3.6 150 FTG E3R PE 0.0 E 12.2 0.0 14.9 0.0 0.016 TL 44.45 PV Pipe: 12 -17.0 1.394 PL 10.25 PF 0.2 E 12.2 0.0 14.9 0.0 3.6 150 FTG E PE 0.0 TOR 12.2 0.0 15.1 0.0 0.016 TL 14.05 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 1 1HD CALC.SDF JOB TITLE: AREA 1 1HD (18xl8) (17 GPM) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -17.0 1.394 PL 8.25 PF 0.2 TOR 12.2 0.0 15.1 0.0 3.6 150 FTG R PE 3.6 FS1 4.0 0.0 18.8 0.0 0.016 TL 10.55 PV Pipe: 14 FIXED PRESSURE LOSS DEVICE FS2 4.0 0.0 21.8 0.0 3.0 psi, 17.0 gpm FS1 4.0 0.0 18.8 0.0 Pipe: 15 -17.0 1.394 PL 3.50 PF 0.5 FS2 4.0 0.0 21.8 0.0 3.6 150 FTG 27.0 PE 1.5 BOR 0.5 0.0 23.8 0.0 0.016 TL 30.50 PV Pipe: 16 -17.0 1.291 PL 2.00 PF 0.3 BOR 0.5 0.0 23.8 0.0 4.2 150 FTG 2ET PE 0.0 DOM 0.5 H.S. 24.2 5.0 0.023 TL 15.00 PV Pipe: 17 -22.0 1.291 PL 3.00 PF 0.5 DOM 0.5 H.S. 24.2 5.0 5.4 150 FTG EC PE 1.5 UG -3.0 0.0 26.2 0.0 0.037 TL 14.00 PV Pipe: 18 -22.0 1.598 PL 85.00 PF 1.2 UG -3.0 0.0 26.2 0.0 3.5 150 FTG 2E PE 0.0 M -3.0 SRCE 27.5 (N/A) 0.013 TL 93.00 PV NOTES (HASS): (1) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 50081438 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.005 gpm and a maximum imbalance at any node of 0.090 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 5.7 ft/sec at pipe 4. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node M under full flow conditions is 34.52 psi with a flow of 25.20 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 1 1HD CALC.SDF JOB TITLE: AREA 1 1HD (18xl8) (17 GPM) (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVly Gate 1.101 1.40 2.50 6.00 1.70 1.00 8.00 0.40 1.394 1.80 3.80 7.30 2.30 1.00 11.00 0.80 1.598 2.10 4.00 8.40 2.70 1.00 14.00 1.00 PAGE: M MATERIAL: CT-M HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVly GatVly NPTee 1.291 3.00 7.00 1.00 2.00 0.50 8.00 0.00 7.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 1 1HD CALC.SDF JOB TITLE: AREA 1 1HD (18xl8) (17 GPM) WATER SUPPLY ANALYSIS Fixed Source Pressure: 34.52 psi 50. G A 40. U G E 1 30.0 P R 2 E S S 20.0 U R E { p s i 10.0 9 -14.7 LEGEND 1 j Available pressure 34.52 psi @ 22.0 gpm 2 l Required pressure 27.46 psi @ 22.0 gpm A. Source Supply Curve B. System Demand Curve 600900 1200 1500 1800 2100 2400 2700 3000 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 1 1HD CALC.SDF JOB TITLE: AREA 1 1HD (18x18) (17 GPM) WATER SUPPLY CURVE 36+ I I 33+ I I I 30+ I I X 27+ I I I P 24+ R E S S 21+ U I R E 18+ ( I P I S I 15+ I I I 12+ I I I 9+ I I I------------------------------ 6+ LEGEND " I" X = Required Water Supply " 27.46 psi @ 22.0 gpm " 3+ " I 0 = Available Water Supply " 34.52 psi @ 22.0 gpm " I" 0++-+---+----+-----+------+--------+----------+---------+-----------+ 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 dkA E: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 2 2HD CALC.SDF JOB TITLE: AREA 2 2HD (16x16) (13 GPM) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) M (N/A) 34.5 (N/A) 34.5 31.2 28.8 (2.3 34. Salo AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) P1 11.8 - - - - 11.1 P2 11.8 K= 4.90 7.0 13.0 P3 11.8 K= 4.90 7.3 13.2 1 12.2 - - - - 10.9 2 12.2 - -- - - 6.9 - - - 3 12.2 - - - - 7.2 A 12.2 - - - - 10.9 - - - B 13.2 - - - - 8.5 -- - - C 12.2 - - - - 8.0 - - - D 12.2 - - - 11.5 - - - E 12.2 - 13.1 -- - - TOR 12.2 - - - - 13.6 FS1 4.0 - - - - 17.6 - - - FS2 4.0 - - - - 20.6 - - - BOR 0.5 -- - - - 23.2 - - - DOM 0.5 HOSE STREAM 23.9 5.0 UG -3.0 - - - - 26.5 - - - M -3.0 SOURCE 28.8 31.2 /21 i N! ✓H v--3e L S �j4f C APPROVAL Cu�+' f t7G5�G ►.� N -j2 5 r Riverside County Fire Department P $y: .-O o, " al 0 Kes c The 2-� approval of plans and specifications does not perrnit the violation, deletion, omission or faulty installatfon of any reiluirements of Titfe 24 or any Local Ordinances. Construction shalt remain accessible and exposed for inspection purposes until approved by the fire De part3iient. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 GATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 2 2HD CALC.SDF JOB TITLE: AREA 2 2HD (16xl6) (13 GPM) PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 0.0 1.101 PL 0.50 PF 0.0 P1 11.8 0.0 11.1 0.0 0.0 150 FTG E PE -0.2 1 12.2 0.0 10.9 0.0 0.000 TL 3.00 PV Pipe: 2 -13.0 1.101 PL 0.50 PF 0.1 P2 11.8 4.9 7.0 13.0 4.4 150 FTG E PE -0.2 2 12.2 0.0 6.9 0.0 0.031 TL 3.00 PV Pipe: 3 -13.2 1.101 PL 0.50 PF 0.2 P3 11.8 4.9 7.3 13.2 4.4 150 FTG T PE -0.2 3 12.2 0.0 7.2 0.0 0.032 TL 6.50 PV Pipe: 4 0.0 1.101 PL 18.25 PF 0.0 1 12.2 0.0 10.9 0.0 0.0 150 FTG ETR PE 0.0 A 12.2 0.0 10.9 0.0 0.000 TL 28.45 PV Pipe: 5 -13.0 1.101 PL 9.25 PF 0.3 2 12.2 0.0 6.9 0.0 4.4 150 FTG R PE 0.0 3 12.2 0.0 7.2 0.0 0.031 TL 10.95 PV Pipe: 6 -26.2 1.101 PL 0.50 PF 0.7 3 12.2 0.0 7.2 0.0 8.8 150 FTG T PE 0.0 C 12.2 0.0 8.0 0.0 0.112 TL 6.50 PV Pipe: 7 11.7 1.101 PL 61.75 PF 2.0 A 12.2 0.0 10.9 0.0 3.9 150 FTG 2ET4R PE -0.4 B 13.2 0.0 8.5 0.0 0.025 TL 79.55 PV Pipe: 8 11.7 1.101 PL 22.25 PF 1.0 B 13.2 0.0 8.5 0.0 3.9 150 FTG 2ET3R PE 0.4 C 12.2 0.0 8.0 0.0 0.025 TL 38.35 PV Pipe: 9 -14.6 1.101 PL 68.25 PF 3.6 C 12.2 0.0 8.0 0.0 4.9 150 FTG 4ET6R PE 0.0 D 12.2 0.0 11.5 0.0 0.038 TL 94.45 PV Pipe: 10 -11.7 1.101 PL 21.25 PF 0.6 A 12.2 0.0 10.9 0.0 3.9 150 FTG 2R PE 0.0 D 12.2 0.0 11.5 0.0 0.025 TL 24.65 PV Pipe: 11 -26.2 1.394 PL 33.75 PF 1.6 D 12.2 0.0 11.5 0.0 5.5 150 FTG E3R PE 0.0 E 12.2 0.0 13.1 0.0 0.036 TL 44.45 PV Pipe: 12 -26.2 1.394 PL 10.25 PF 0.5 E 12.2 0.0 13.1 0.0 5.5 150 FTG E PE 0.0 TOR 12.2 0.0 13.6 0.0 0.036 TL 14.05 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 2 2HD CALC.SDF JOB TITLE: AREA 2 2HD (16x16) (13 GPM) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -26.2 1.394 PL 8.25 PF 0.4 TOR 12.2 0.0 13.6 0.0 5.5 150 FTG R PE 3.6 FS1 4.0 0.0 17.6 0.0 0.036 TL 10.55 PV Pipe: 14 FIXED PRESSURE LOSS DEVICE FS2 4.0 0.0 20.6 0.0 3.0 psi, 26.2 gpm FS1 4.0 0.0 17.6 0.0 Pipe: 15 -26.2 1.394 PL 3.50 PF 1.1 FS2 4.0 0.0 20.6 0.0 5.5 150 FTG 27.0 PE 1.5 BOR 0.5 0.0 23.2 0.0 0.036 TL 30.50 PV Pipe: 16 -26.2 1.291 PL 2.00 PF 0.8 BOR 0.5 0.0 23.2 0.0 6.4 150 FTG 2ET PE 0.0 DOM 0.5 H.S. 23.9 5.0 0.052 TL 15.00 PV Pipe: 17 -31.2 1.291 PL 3.00 PF 1.0 DOM 0.5 H.S. 23.9 5.0 7.6 150 FTG EC PE 1.5 UG -3.0 0.0 26.5 0.0 0.071 TL 14.00 PV Pipe: 18 -31.2 1.598 PL 85.00 PF 2.4 UG -3.0 0.0 26.5 0.0 5.0 150 FTG 2E PE 0.0 M -3.0 SRCE 28.8 (N/A) 0.025 TL 93.00 PV NOTES (HASS): (1) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 50081438 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.006 gpm and a maximum imbalance at any node of 0.106 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 8.8 ft/sec at pipe 6. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node M under full flow conditions is 34.52 psi with a flow of 35.10 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 6AtE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 2 2HD CALC.SDF JOB TITLE: AREA 2 2HD (16xl6) (13 GPM) (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkVly Gate 1.101 1.40 2.50 6.00 1.70 1.00 8.00 0.40 1.394 1.80 3.80 7.30 2.30 1.00 11.00 0.80 1.598 2.10 4.00 8.40 2.70 1.00 14.00 1.00 PAGE: M MATERIAL: CT-M HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVly GatVly NPTee 1.291 3.00 7.00 1.00 2.00 0.50 8.00 0.00 7.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 2 2HD CALC.SDF JOB TITLE: AREA 2 2HD (16xl6) (13 GPM) WATER SUPPLY ANALYSIS Fixed Source Pressure: 34.52 psi .1 we 50.0 G A 40.0 U G E 1 30.0 P 2 R E S S 20.0 U R E 10.0 nmm�mn n,., �� n.ns,mmmmnrmm,.mnrmmnr.n ,� ,.omwarwumou,:mun oo.u,omu, ,M ,..r nu, i,omiumm, ummwm, i II -14.7 LEGEND L j Available pressure 34.52 psi @ 31.2 gpm lRequired pressure 28.82 psi @ 31.2 gpm A. Source Supply Curve B. System Demand Curve 600900 1200 1500 1800 2100 2400 2700 3000 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 2 2HD CALC.SDF JOB TITLE: AREA 2 2HD (16xl6) (13 GPM) WATER SUPPLY CURVE 36+ I I 33+ I I I 30+ 1 X 1 27+ I I I P 24+ R I E I S S 21+ U R E 18+ ( I P S I 15+ I I I 12+ I I I 9+ I I 6+ _____________________ LEGEND I" X = Required Water Supply " I 28.82 psi @ 31.2 gpm " 3+ " I 0 = Available Water Supply " I" 34.52 psi @ 31.2 gpm " 0++-+---+----+-----+------+--------+--------+---------t-----------+ 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) Page 1 of 5 NJJQ FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric'), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS C&S UL Listed (C-UL-US-EU): Category VKKW e6 Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric') Glass -bulb fluid temperature rated to -65 °F (-55 °C) WARNING: Cancer and Reproductive Hann- www.P65Wamings.ca gov Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom-` Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Standard Cover Plates: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Form No. F_012116 18.10.11 Rev 18.1.P65 Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning ) Page 2 of 5 f§11 FREEDOM® RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-946-9601 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B4B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C =A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches": A. Heavy Duty Part No. 14047W/B" (available since 2006), or B. Head Cabinet Wrench Part No. 14031" (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Lover Plate Installer Tool Part No. 1486_� (available since 2007) "Requires a +/V ratchet (not available from Viking). -Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly.. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS ■ Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Bulb Color Classification Temperature Ceiling Assembly Base Part Base Part Base Part Rating' Temperature' (Required)' Number' Number' Number' Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 13504 or 13642 or 15394 Red 21876' 21875' Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 13504 or 13642 or 15394 Green 218766 21875' Sprinkler Finishes: Brass and ENT Cover Plate Finishes': Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings': ENT Footnotes +• The sprinkler temperature rating is stamped on the deflector. 7 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Maximum ambient temperature for cover assembly is 100 °F (38 °C). +• Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 5 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts These tests cannot and do not represent all possible corrosive environments Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed e Stainless Steel versions are not available with any finishes or paint Form No. F_012116 18.10.11 Rev 18.1. P65 Page 3 of 5 001ILFRE EDOM® RESIDENTIAL NCEALED PENDENT RINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart Viking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Water Wor- Inches mm U.S. T metric 2 Part Number king Pressure 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage 6 Flow GPM Pressure Listings and Minimum Area W X L (LPM) PSI (bar) Deflector to ns Installation Approvals'.5 Sin Spacing Ft. X Ft. Ceiling Type Ft. (m) 155 °F (68 °C), 200 °F (93 °C) Temperature a 4L us 4 (m X m) Rated Sprinklers Err 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Concealed with Cover Plate See Footnotes 7,9, 10, 8 16 X 16 13 7.0 (4.9 X 4.9) (49.2) (0.48) Refer to Figure 2 Assembly. See Footnote 8 & 11 (2.4) 18 X 18 17 12.0 (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X 6.1) (75.7) (1.15) Footnotes + Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. ,• This chart shows the listings and approvals available at the time of printing. Other approvals may be in process Check with the manufacturer for any additional approvals. Refer also to Design Criteria l Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union 6 Meets New York City requirements, effective July 1, 2008 6. For areas of coverage smaller than shown, use the "Flow" and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow' and "Pressure" used. 7. Cover Temperature Rating is 135 °F (57 °C). Cover Part No 135041, 13642+ (large diameter), or 15394+ (square cover plate). 6. Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. e. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 6 +o•C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) ++. Stainless Steel Cover plate temperature rating is 135 "F (57 °C). Stainless Steel Cover Part Numbers: 21876+ and 21875+ (large diameter). Form No. F_012116 18.10.11 Rev 18.1.P65 Page 4 of 5 FREEDOM® RESIDENTIAL A A • CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Atso refer to the Approval Chart an page 3.) UL Listing Requirements, 1Q- L-11-E111: When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** r Sprinkler Wrench Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. 2-1/4" (57 mm) neter opening sired in the ing. Step 2: t t Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat . {{ Sprinkler frame arms � r Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Form No. F_012116 18.10 11 Rev 18.1.P65 Page 5 of 5 FREEDOM° RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1/2" (15 mm) NPT N 0 - 2-9/16" (65 mm) Maximum NOTE: Upon sprinkler activation, the deflector descends to approximately 13116" (21 mm) below the sprinkler body. 2-1/16" (52 mm) Minimum q � � 2-3/4" (70 mm) or 3-5/16" (84 mm) Figure 2: Sprinkler Dimensions and Cover Installation QQ�\gyp CUS 7-0 o a �2 O c� U� O MS All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label Figure 3: Identification of Custom Paint for Concealed Covers -. 3-5/16" (84 mm) Figure 4: Square Cover Assembly 15394 Form No F-012116 18 10.11 Rev 18.1.P65 Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) N11KINGA a Page 1 of 5 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK331 dK41% The Viking Corporation, 210 N Industrial Parr Drive, Hastings MI 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax, 269418-1gg0 Entail: techsvcs@vikingcorp.com I. DESCRIPTION The Viking Microfaste Quick Response Pendent Sprinkler VK331 Is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tem- perature ratings to meet design requirements. The special Polyester and PTFE addition, these coatings have been investigated for installation in corcoatings can be used in decorative applications where colors are desired. In rosive atmos- pheres and are I:stedlapproved as corrosion resistant as indicated in the Approval Charts. 2. LISTINGS AND APPROVALS COw cULus Listed: Category VNIV Refer to Approval Chart 1 and Design Criteria cULus Listing requirements. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 250 psi (17 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 112" NPT, 15 mm BSP Nominal K-Factor; 4.2 U.S. (57 metric") Glass-bu!b fluid temperature rated to -65 OF (-55 °C) Overaii Length: 2-114" (58 mm) Material ftridards: Frame Casting: Brass UI,,[S-C84400 Deflector: Brass UN-CS6000 000 Bushing; Brass UN5-C3$Viking Technical Data may be found on Bush Bulb: Glass, nominal 3 mm diameter The Viking eonponstion's W%b site at Belleville Spring Sealing Assembly; Nickel Alloy, coated on both sides with The Web eke may Include a more recent PTFE Tape Screw: Brass UNS-C36000 edition of this Technical Data Page. Pip Cap and Insert Assembly: Copper L1NS-C11000 and Stainless Steel UNS- S30400 For PTFE Coo i ' Belleville Spring -Exposed, Screw Nickel Plated, Pip Cap-PTFE Coated F Polye :ar Coated Sprinklers: Belleville Spring -Exposed Ordering information. (Also refer to the current Viking price list.) Order Viking Micrvfast' Quick Response Pendent Sprinkler VK331 by first adding the appropriate suffer for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-NV, Black Polyester = M-IB, and Black PTFE = N Temperature Suffix: 135 OF (68 `C) = A, 155 OF (68 *C) = B, 175 °F (79 "C) = D, 200 OF (93 °C) = E, 286 OF (141 °C) = G For example, sprinkler VK331 with a Brass frnish and a 155 "F (68 °C) temperature rating = Part No. 06720BAB Available Finishers And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) SPrinider Wrenches: A. Standard Wrench: Part No. 10895W113 (available since 2000). B. Wrench for Recessed Pendent Sprinklers: Part: No. 16()36W18*" (available since 2011) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool, Part No. 15915 (available since 2010) A %" ratchet is required (not available from Viking). ' Allows use from the floor by attaching a length of V diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F 051808. Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A (available since 1971) B. Twelve -head capacity. Part No. 01725A (available since 1971) Form No. F 061814 Rev 14.1 (New page for VK331) Page 2 of 5 MICROFAST® QUICK RESPONSE `- ' PENDENT SPRINKLER y VK331 (K4.2) The Viking Corporation, 210 N industrial Park Drive, Hastings 49068 Telephone: 269-945-9601 Technical Services: 877 384-5464 Fax: i 2 9-818-1680 Email- techev cs@vlkingcorp.com 4. INSTALLATION Refer to appropriate NFPA Installation Standards. S. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. , 7. AVAILABILITY _.-The Viking Microfase Quick Response Pendent Sprinider VK331 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. S: GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_061814 Rev 14.1 Cap Page 3 of 5 ® MICROFAST® . QUICK RESPONSE PENDENT SPRINKLER VK331 (K4.2) VikingThe Telephone: 269-945-9501 Technical Services: 877 384-5494 Fax: 289-818- 680 Email: tochavcs@vlkfngcorp.com � gcorp.com S +riri'dar T n¢e tztra S' - , mum Z baImit Temp re Rating, Coiling Terrrperaturez Sulb Color Ordinary 135 °F (57 °C) 100 OF (38 °C) Orange Ordinary 165 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F {65 °C) Green High 286 °F (141 °C) 225 °F (107 -C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and Black PTFE Corrosion -Resistant Coating83: White Polyester, Black Polyester, and Black PTFE Footnotes ' The sprinkler temperature rating is stamped on the deflector, ' Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. -RUer to specific installation standards. 'The -corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. —Note that the spring is exposed on sprinklers with Polyester and PTFE coatings. ` J ,,Sprinkler wrench 16036W/ for recessed pendent sprinklers " A 1/21, ratchet is requin (not available from Vikin4 - _t6l� Carefully slide the wrench sideways around the protective cap, ensuring engagement witl the sprinkler wrench flats Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers Form No. F_061814 Rev 14.1 Page 4 of 5 NJ1VJW4J a MICROFAST'1 QUICK RESPONSE PENDENT SPRINKLER VK331 (K4.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-6464 Fax: 269-818-1680 Email: tachsvcs@vikingcorp.com Base Part SIN Number' - (UL) Tina Viking WC!—ofa----t` QEdCk Response Pendent -Sprinkler VK331 maximum17- Psi o2 13ar)1l5iVp Sprinkler Thread Size Nominal K-Factor Overall Length Style NPT I BSP I U.S. 06720E VK331 Pendent 1/2" 15 mm 4.2 Approved Temperature Ratings A- 135 IF (57 °C), 155 IF (68 °C), 175 IF (79 'C), 200 IF (93 °C), 286 IF (141 °C) B'�- 135 IF (57 °C), 155 IF (58 'C), 175 IF (79 IC), and 200 IF (93 °C) metric I inches I mm 57 1 2-1/4 Approved Finishes 1 - Brass, Chrome, White Polyester5A, Black Polyes- ter5.6, and Black PTFE6 ,� A ) EUWALQ,,,, rar,aas ,en,,3 Listings and Approvals' (Refer also to Design Criteria.) cULLW I VdS I LPCB 58 A1X, B1Y I -- I — _ Approved Escutcheons X - Standard surface -mounted escutcheon or the Viking Micromatl& Model F-1 Adjustable Escutcheon Y - Standard surface -mounted escutcheon or the Viking Microfas? Model F-1 Adjustable Escutcheon, or recessed with the Viking Micromati& Model E-1, E-2, or E-3 Recessed Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure Is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. s cULus Listed as corrosion -resistant. e Other colors are available on request with the same Listings and Approvals as the standard colors. DESM IQTT €A - (Alsb refb: to Appro►af Ci,,art 7 above.) -s es n� R,g9l��me:�,s• The Viking Microfast® Quick Response Pendent Sprinkler VK331 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. - Small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance Information. Viking sprinklers are to be Installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_061814 Rev 14.1 Page 5 of 5 N_11K1W4j a MICROFASTO QUICK RESPONSE PENDENT SPRINKLER _ VK331 (K4.2) VikingThe Corporation, Industrial Telephone: 269-945-9501 T chni alServices: 877 384- 464F Fax: 269-818- techsvcs@vikingcorp.com Email: techsvcs � gcorp.com Ceiling Opening Size: 1/21' 2-516P' (58.7 mm) minimum (15 mm) i 2-1/2" (63.5 mm) maximum NPT (54 mm) 2-114„� (57 mm) 2ps T (38 mm) mm) (44.5 mm) (51 Min. Max. , Installed with a standard Installed with a Microfast 1/8" surface -mounted NOW At maximum, adapter is Model F-1 Adjustable exposed 112" (12.7 mm)from escutcheon Escutcheon face of ceiling Figure 3: Sprinkler Dimenslons with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Ceiling Opening Size: 2-516P' (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 2-118" 2-1/81, .A (54 mm} (54 mm) IT'1 M i-314" -1/8" T 5 ♦1-1/8„ 28.6 mm 2"" (44.5 mm) ( ) Min. (51 mm) i°. (2 Min. Max. Max. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread -on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_061814 Rev 14.1 (New page for VK331) Fig. 28 - "Stand -Off" Hanger & Restrainer for CPVC Plastic Pipe 0@USLISTED Size Range — 3/4" through 2" Material — Carbon Steel, Pre -Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: i. • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. Unique twist and lock design holds pipe firmly in place and allows retrofit type B A ■ of installation. �( • The "Stand -Off" design eliminates the need for wood block extension. C (+ ■ Can be installed on horizontal or vertical piping regardless of mounting + surface orientation. • Attaches easily to wood structure with two hex head self -threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe. ., • Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals — Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satis- fies the UL vertical restraint requirement where needed. UL Listed as a hanger and ver- tical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. I + Order by — Figure number and pipe size. Pat. # 7,455,268, Pat. # 7,832,248 FIG.278 (Jj fiCCIUlfi_❑ FIG2M 1\2lh 's`�^ _ (2) REQUIRED OFHANGER Dimensions • Weights HANGER & RESTRAINT Pipe HANGER APPLICATION APPLICATION Sze A B C Approx. 3/4 31/32 2 31/2 .180 1 35/16 23/1e 31/2 .210 11/4 35/8 23/a 31/2 .225 11/2 4 21/2 31/2 .310 FIG3e- 14 2 41/2 211/16 3% .340 FIG.28 F10.76 � Fan • I`♦ OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92679 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786 5266 www.talco.com Pipe Clamps_ T w A TOLCOTM' Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe Size Range: Available in 3/4" (20mm) and 1" (25mm) pipe sizes Material: Pre -Galvanized Steel Function Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2" (20mm) x 11/2" (20mm) from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. ■ Attaches easily to wood structure with two special #10 x 1 " hex head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre -Galvanized Order By: Part number and pipe size. Patent Pending Pipe Size Approx. Wt,/100 Pert No. in. (mm) lbs. (kg) 29-3/4 3/4' (20) 17.0 (7.7) 29-1 1" (25) 18.6 (8.4) Double Offset Single Offset c& us USTEO (38.1mm) (38.1mm) J----------, 0 I 0 n 1.5" �+ (38.1mm) I r------------ r1 I--- 1.5"--- (38.1 mm) Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self -tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 103 B-Line series Pipe Hangers & Supports tqCC Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 BlazeMaster CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially devel- oped thermoplastic compound com- posed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFBP BlazeMaster CPVC products are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as com- pared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic pip- ing. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. WARNING Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities ha v- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Sizes 3/4" to 3" Maximum Working Pressure 175 psi Approvals UL, FM, CUL, NSF, Dade County, LPCB, MEA, and the City of Los Ange- les. (Refer to IH-1900, Rev. 0, Janu- ary 2005 "Installation Instruction & Technical Handbook" for exact list- ing/approval information.) Manufacture Source U.S.A. Material • Pipe: ASTM F442, SDR 13.5 • Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange Aft rapid response M HOME FIRE SPRINKLER SYSTEM BlazeMaster® is a registered trademark of Noveon IP Holding Corp. Page 1 of 6 JANUARY, 2006 TFP1915 Page 2 of 6 TFP1915 WATER NOMINAL AVERAGE AVERAGE WEIGHT FILLED WEIGHT FT OF PIPE WEIGHT PER LIFT SIZE O.D. I.D. Ibs./ft. Ibs.ffL PER LIFT lbs. 3/4" 1.050" 0.874" 0.18 0.44 7875 1339 V. 1.315" 1.101, 0.26 0.67 5040 1320 1-1 /4" 1.660" 1.394" 0.42 1.08 2835 1191 1-1/2" 1.900" 1.598" 0.54 1.41 2205 1213 2" 2.375" 2.003" 084 2.20 1260 1084 2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531 3" 3.500" 2.952" 1.87 4.83 720 1344 Installation Tyco Fire and Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- ance with IH-1900, Rev. 0, January 2005 "Installation Instruction & Techni- cal Handbook". FIGURE 1 — PIPE DIMENSIONS Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. TFP191 5 Page 3 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (T/O) (lb.) TEE 80000 3/4" 5/8" 40 0.11 T/O 80001 1° 11/16" 40 0.19 4- i 80002 1-1 /4" 7/8" 40 0.26 80003 1-1/2" 1-1/16" 80 0.51 80004 2" 1-3/8" 80 0.90 80005 2-1/2" 1-9/16" 80 1.59 T/O T/O 80006 3" 1-13/16" 80 2.41 XxYxZ X Y Z 3/4" x 3/4" x 1" 3/4" 3/4" 5/8" 80132 40 0.14 80133 1" x 3/4" x 3/4" 9/16" 9/16" 3/4" 40 0.14 80134 1 " x 3/4" x 1" 3/4" 11 A 6" 3/4" 40 0.17 80260 1" x 1" x 3/4" 5/8" 5/8" 13/16" 40 0.16 80135 1-1 /4" x 1 " x 3/4" 5/8" 5/8" 15/16" 40 0.21 80136 1-1/4" x 1" x 1" 3/4" 3/4" 15/16" 40 0.22 80137 1-1/4" x 1" x 1-1/4" 15/16" 15/16" 7/8" 40 Q26 REDUCING TEE 80261 1-1 /4" x 1-1 /4" x 3/4" 5/8" 5/8" 7/8" 40 0-23 80262 1-1 /4" x 1-1 /4" x 1" 3/4" 3/4" 7/8" 40 0.26 Z 80138 1-1/4" x 1-1/4" x 1-1/2" 1" V. 1" 80 0.43 T/O 80140 1-1/2" x 1-1/4" x 3/4" 9/16" 9/16" 1" 80 0.36 80141 1-1/2" x 1-1 /4" x 1" 9116" 9/16" 1-1116" 80 0.38 80263 80264 1-1/2" x 1-1/2" x 3/4" 1-1/2" x 1-1/2" x 1" 9/16" 9/16" 9/16" 9/16" 1" 1-1/16" 80 80 0.36 0.38 X Y !!!T/O 80275 1-1/2" x 1-1/2" x 1-1 /4" 7/8" 7/8" ill 80 0.45 T/O 80265 2" x 2" x 3/4" 3/4" 3/4" 1-3/8" 80 0.61 80266 2" x 2" x 1" 7/8" 7/8" 1-3/8" 80 0.66 80274 2" x 2" x 1-1 /4" 1-1 /16" 1-1 /16" 1-3/8" 80 0.74 80267 2" x 2" x 1-1/2" 1-1/8" 1-1/8" 1-3/8" 80 0.78 80271 2-1/2" x 2-1/2" x 1" 1-9/16" 1-9/16" 1-9/16" 80 1.43 80272 2-1/2" x 2-1/2" x 1-1 /4" 1-9/16" 1-9/16" 1-9/16" 80 1.46 80273 2-1/2" x 2-1/2" x 1-1/2" 1-9/16" 1-9/16" 1-9/16" 80 1.48 80276 2-1/2" x 2-1/2" x 2" 1-9/16" 1-9/16" 1-9/16" 80 1.50 80270 3" x 3" x 1-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.28 80268 3" x 3" x 2" 1-13/16" 1-13116" 1-3/4" 80 2.25 80269 3" x 3" x 2-1/2" 1-13/16" 1-13/16" 1-13116" 80 2.44 CROSS & REDUCING CROSS 80009 3/4" 9/16" 40 0.13 T/O 80010 1" 11/16" 40 0.23 80011 1-1/4" 15/16" 40 0.34 80012 1-1/2" 1-1 /16" 80 0.67 80013 2" 1-5/16" 80 1.00 80014 2-1/2" 1-9/16" 80 1.91 T/O 80008 3" 1-13/16" 80 2.89 80015 1" x 1" x 3/4" x 3/4" 7/8" 40 0.28 T/O T/O 80025 3/4" 5/8" 40 0.09 90° ELBOW & REDUCING ELBOW 80026 1" 3/4" 40 0.14 80027 1-1/4" 7/8" 40 0.21 X 80028 1-1/2" 1-1/16" 80 0.40 T/10 80029 2" 1-5/16" 80 079 80030 2-1/2" 1-9/16" 80 114 Y 80031 3" 1-13/16" 80 1.82 XxY X Y T/O 80032 1" x 3/4" 11/16" 13/16" 40 FIGURE 2 - FITTING DIMENSIONS (Part 1 of 4) Page 4 of 6 TFP1915 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD WEIGHT TYPE NUMBER (T/O) . (Ib•) 45° ELBOW 80050 3/4" 3/8" 40 0.08 T/O 80051 1" 3/8" 40 0,11 80052 1-1/4" 3/4" 40 0,20 80053 1-1/2" 1/2" 80 0.31 T/O 80054 2" 314" 80 0.56 80055 2-1/2" 13/16" 80 0.89 80056 3" 1" 80 1,19 80075 3/4" 1 /8" 40 0.07 COUPLING & 80076 1" 1/8" 40 0.11 REDUCING COUPLING 80077 1-1/4" 3/16" 40 0.12 80078 1-1/2" 3/16" 80 0.25 80079 2" 3/16" 80 0.38 80080 2-1/2" 1 /4" 80 0,67 - - T/O 80081 3" 3/16" 80 0.91 80220 1" x 3/4" 1/8" 40 0.08 80200 1"x3/4" 7/16" 40 0.04 80201 1-1/4" x 3/4" 1 /2" 40 0.11 80202 1-1/4" x 1" 5/16" 40 0.12 80203 1-1/2"x3/4" 5/8" 80 0,16 80204 1-1 /2" x 1 " 1 /2" 80 0.14 REDUCER BUSHING 80205 1-112" x 1-1/4" 3/8" 80 0.17 80206 2" x 3/4" 13/16" 80 0.27 80207 2" x 1 " 11 A 6" 80 0.26 80208 2" x 1-1 /4" 9/16" 80 0.24 80209 2" x 1-1 /2" 7/16" 80 0.19 -I T/O 80215 2-1/2" x 1" 15/16" 80 0.42 80214 2-1/2" x 1-114" 13/16" 80 0.45 80213 2-1/2" x 1-1/2" 11 /16" 80 0.46 80211 2-1/2" x 2" 5/8" 80 0.29 80210 3" x 2" 3/4" 80 0.72 80212 3" x 2-1/2" 112" 80 0.47 CAP 80100 3/4" 5/16" 40 0.04 80101 1" 3/8" 40 0.06 80102 1-1 /4" 7/16" 40 0,10 80103 1-1/2" 11 /16" 80 0.20 80104 2" 5/8" 80 0.31 80105 2-1/2" 7/8" 80 0.58 T/O - 80106 3" 1" 80 0.88 GROOVED T/O PIPE O.D. COUPLING ADAPTER 80160 1-1/4" x 1-1/4" Groove 2-5/16" 1-1/4" (1,660") 40 0.78 I 80161 1-1/2" x 1-1/2" Groove 2-5/16" 1-1/2" (1.900") 80 0.95 PIPE 80162 2" x 2" Groove 2-5/16" 2" (2.375") 80 1.42 O.D. 80163 2-1/2" x 2-1/2" Groove 2-5/16" 2-112" (2,875") 80 2.28 80164 3" x 3" Groove 2-1/4" 3" (3.500") 80 3.00 T/O -i 80169 2-1/2" x 76,1 mm Groove 2-5/16" 76,1 mm (3.000") 80 2.28 FIGURE 2 - FITTING DIMENSIONS (Part 2 of 4) TFP1915 Page 5 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (T/O) (lb.) SPRINKLER HEAD ADAPTER 80175E 3/4" x 1/2" NPT 7/16' 80 0.20 80176E 1 " x 1/2" NPT 7/16" 80 0.22 [;; 80175WL 3/4" x 1/2" NPT 7/16" 40 0.16 80179 1" x 3/4" NPT 13/16" 40 0.43 SPRINKLER HEAD ADAPTER 80175W 3/4" x 1/2" NPT 1/2" 40 0.19 AT 80176W 1" x 1/2" NPT 1/2" 40 0.18 SPRINKLER HEAD ADAPTER (SPIGOT) 80177L 3/4" x 1/2" NPT 112" 40 0.16 80178 1" x 1/2' NPT 9/16" 40 0.20 7T/080180 1"x 3/4"NPT 7/8" 40 0.40 FEMALE ADAPTER 80142 3/4" x 3/4" NPT 13/16" 40 0.41 80145 1' x 1" NPT 7/8" 40 0.63 80146 1-1/4" x 1-1/4" NPT 1-1/8'. 40 1.03 80147 1-1/2" x 1-1/2" NPT 1-3/8" 80 1.42 80148 2" x 2" NPT 1-11/16" 80 Z66 T/O MALE ADAPTER 80157 3/4" x 3/4" NPT 1-5/16' 40 0.33 ro —I 80158 1' x 1" NPT 1-3/8" 40 0.56 xxYxZ x Y Z SPRINKLER HEAD ADAPTER TEE 80250 3/4" x 3/4" x 1/2" NPT 9/16" 9/16" 1" 40 0.22 Z 80251 1" x 1" x 1/2" NPT 11/16" 11/16" 1-3/16" 40 0.29 T/O 80249 1" x 1" x 1" NPT 15/16" 15/16" 1-9/16" 40 0.73 80256 1-1/4" x 1" x 1/2" NPT 7/16" 9/16" 1-5/16" 40 0.30 80252 1-1/4" x 1-114" x 1/2" NPT 7/16" 7/16" 1-5/16" 40 0.31 4T/0i=T/,0 80257 1-1 /2" x 1-1 /4" x 1/2" NPT 1/2" 11 /16" 1-7/16" 80 0.43 x Y I 80254 1-1 /2" x 1-1 /2" x 1/2" NPT 1/2" 1/2" 1-7/16" 80 046 80258 2" x 1-112" x 1/2" NPT 1/2" 5/8" 1-11/16" 80 0.56 80253 2" x 2" x 1/2" NPT 1/2" 1/2" 1-11 /16" 80 0.62 FIGURE 2 — FITTING DIMENSIONS (Part 3 of 4) Page 6 of 6 TFP1915 FITTING TYPE PART NUMBER NOMINAL SIZE NOMINAL TAKE-OUT (T/O) SCHD. WEIGHT (Ib•) BACK-TO-BACK TEE X x Y x Z X Y, Z x T/O I Y 80459 1" x 1/2" NPT x 1/2" NPT 5/8" 1-5/16" 40 0.48 80460 1" x 1/2" NPT x 1/2" NPT 5/8" 1-3/16" 40 046 Z 1 F T/O BACK-TO-BACK CROSS X x Y x Z x W X, Y Z, W x T/O I z 80462 80463 1"xi"x1/2"NPT x1/2"NPT 1" x 1" x 1/2" NPT x 1/2" NPT 5/8" 5/8" 1-3/16" 1-5/16" 40 40 046 047 WI T/O Y T/O T/0 SPRINKLER HEAD X x Y X Y ADAPTER 90° ELBOW Y O 80199 3/4" x 1/2" NPT 9/16" 1" 40 0.20 80198 1" x 1/2" NPT 3/4" 1-1/4" 40 0.26 rI 80196 1"x 3/4" NPT 1-1/16" 1-7/16" 40 0.26 FIGURE 2 — FITTING DIMENSIONS (Part 4 of 4) Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The farpgnina warranty s_made In lieu of any and all other_ warrantieg,_Px- press or implied, inc[udinrg_Warrant ies of merchantability and fitness for apar- titular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 ►�rER Residential Connection Charge Estimate August 13, 2019 Customer Name: Modern Structures, LLC Phone No. (949) 478-1476 Parcel No. 766-031-018 Geo. 06-07-29-1 Address: 79540 Tom Fazio Ln N, La Quinta LID: 664546 Block No. Lot No. 6 Size of Lot: 20,M SCE. ft. Tract No. 32117 Type of Service: YP R-1: Duplex: Triplex: Apts: SWSC: $ - Acres: 0.4 6 SWSC: $0.00 /acre WSBFC: SCC: Treatment: $2,436/edu Collection: $2,415/edu Meter: $ 400.00 Meter Size: inch Meter surcharge: $ 2,479.00 Service size: inch Service: $ - Meter & Service: $ Backflow: Other: Sewer Lateral: $ - Total: $ 2,879.00 LANDSCAPE PLANS REQUIRED. Per Acc# 692231-664546 a 3/4" meter exists. Meter paid on MCR #88823. SCC, WSBFC & SWSC pd on MCR #88843. PZ 19-10221 Technician: Ruben Montiel Fees Approved by: '*44Date: Information Supplied By Customer CVWD System Data Domestic Water Demand* Service Connection** Max. Flow= 5 gpm Max. Flow*= 34.1 gpm Min. Pressure= 20 psi Inlet Pressure 1= 69.26 psi Fire Sprinkler I]emand* Outlet Pressure= 38.36 psi Max. Flow= 34.1 gpm Min. Pressure= 37.9 psi Meter Size = 1 inch System Type: 171 Service Size= 1 inch Multi Stand Alone 1 Prior to Pressure Regulating Valve ** For Calculation Purposes- Service Connection Includes: * CVWD USES WORST CASE CONDITION Service Connection Pipe=L', Meter Stop, Meter, Check Valve & Shut Off Valve Calculations: USE 1 " METER " SERVICE Pz= Lower Quarry Rv' p 69.26 > 60 psi HGL= 194 ' v� `Fl�l�ter= 7.15 RESA= 0 HL- tc.= 23.75 RES./HT= 0 C 5819Q N A7 38.36 > 37.9 psi PROP. ELEV.= 34 * Max 34.10 GPM Ps is OK �q C10- Q� 1 0 C to provide service F r�0F TRY: Fire Sprinkler Demand CA��oved b L pp y: ,�- � _ Date: The meter sizing is for plan check purposes only. The ultimate responsibility resides with the Engineer -of ecord for the pro ject. QaA ra CAI.IFORNIA DESIGN & DEVELOPMENT DEPARTMENT 78-49S Calle Tampico La Quinta, California 92253 (760) 777-7125 / FAX (760) 777-7011 FIRE REVIEW APPLICATION 6 NEW ❑ TENANT IMPROVFMFNT octal PROJECT INFORMATION (Please Pdnt) Project Name: (-qO-f Y LDT Sign: 'j��-�- Site Address: 9- a 90 Tb M-Fa Zt D LN) Print: C� y -era City & Zip: I vyicw Gj a �3 Project Y oao+� JAN 2 1 2020 J CITY OF LA QUINTA DESIGN & DEVELOPMENT DEPARTMENT PERMIT NO. Description: Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the City's fire department, and the County designee serves as the City's fire chief. Applicant recognizes this contracted a►ran ernent and shall comply with County Fire Department dire6ions APPLICANT/CONTACT INFORMATION CONTRACTOR INFORMATION: Mamle as Applicant info Applicant Name: A C ii�l_ y- C �'�Gt�Y1 Contractor #: Contact Person: _ry vl C. l _Cal' 1\\DfC'( Contact Person: c[ Mailing Address: /q - � v C Mailing Address: City &Zip: 112C ifo P s -Q City & Zip: Phone Number: -) �aU -2f -MOed Fax Phone Number: Fmnil- Fmnil- Fax A. APPLICATION TYPE FIRE SPRINKLER SYSTEM STORAGE TANKS ❑ NEW COMMERCIAL/INDUSTRIAL ____________ ❑ DISPENSERS ONLY HOURLY@161/HR HOURLY@161/HR ❑ 0-35,000 SQ FT $670 ❑ ABOVEGROUND —� ❑ 35,001-75,000 SQ FT $791 SUPRESSION SYSTEM ❑ 75,001-120,000 SQ FT $992 ❑ HOOD & DUCT $418 ❑ 120,001 AND UP $1234 ❑ SPRAY BOOTH HOURLY@161/HR ❑ TENANT IMPROVEMENTS - FIRE SPRINKLER $418 ❑ OTHER SUPRESSION SYSTEM HOURLY@161/HR RESIDENTIAL Sprinkler Systems __________ ❑ HAZMAT HOURLY@161/HR 1-50 SPRINKLER HEADS $418 MISC ❑ 51-100 SPRINKLER HEADS $498 ❑ HAZMAT HOURLY@161/HR ❑ OVER 100 SPRINKLER HEADS $579 ❑ HIGH PILE RACK STORAGE HOURLY@161/HR ❑ RESIDENTIAL - (EA) ADDITIONAL $176 ❑ PRIVATE FIRE MAINS $901 ❑ MULTI -FAMILY (3 OR MORE) $590 ❑ TECHNICAL REPORT RESEARCH HOURLY@161/HR FIRE ALARM SYSTEM ❑ FIRE PUMPS $659 ❑ COMMERCIAL - SPRINKLER MONITORING $418 ❑ STANDPIPE SYSTEMS $579 ❑ COMMERCIAL - FIRE ALARM SYSTEM $1062 ❑ WATER TANKS $418 MASTER PLAN ❑ PYRO $740 ❑ MASTER PLAN HOURLY@161/HR ❑ REVISION # HOURLY@161/HR ❑ MASTER PLAN REVISION HOURLY@161/HR I ❑ OTHER HOURLY@161/HR E nch application type includes a Technology Enhancement Fee of $5 & Records Management Fee of $10 or $21 REVISED 10/Z/ZU19 *For permits billed at an hourly rate, these fees will be added at time of payment. f CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT SHAwN C. NEwmAN — FIRE CHIEF OFFICE OF THE FIRE MARSHAL — LA QUINTA CAI.IFORMA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org February 11, 2020 JC Fire Protection 81705 De Oro Avenue Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review — Modern Structure @ The Quarry FSS2020-0013 / 79540 TOM FAZIO LN NORTH, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist