FSS2020-0013Description: MODERN STRUCTURES
Type: FIRE SPRINKLER
Parcel No: 766031018
Subdivision: TR 28189
Lot Sq Ft: 0
Valuation: $0.00
No. Buildings: 0
D� etails
Subtype: RESIDENTIAL -CUSTOM Status: ISSUED
HOMES
Site Address: 79540 TOM FAZIO LN N LA QUINTA,CA 92253
Block: Lot:6
Building Sq Ft: 0
Occupancy Type:
No. Stories: 0
Zoning:
Construction Type
No. Unites: 0
Applied: 1/21/2020 AHI
Approved: 2/11/2020 KHET
Issued: 2/25/2020 JLIM
Finaled:
Expired: 8/23/2020 JLIM
14
21
J Applied to Approved
1 Approved to Issued
ADDITIONAL
•• ffel Felt
CHRONOLOGY TYPE STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
PUBLIC COUNTER VISIT JACK LIMA
2/25/2020
2/25/2020
PERMIT ISSUED TO MICHAEL CORDOVA.
CONDITIONS
CONTACTS
NAME TYPE NAME
ADDRESSI
CITY
STATE
ZIP
PHONE FAX EMAIL
APPLICANT J C FIRE PROTECTION
81705 DE ORO AVENUE
INDIO
CA
92201
JCFIREPROTECTION@V
ERIZON.NET
CONTRACTOR J C FIRE PROTECTION
81705 DE ORO AVENUE
INDIO
CA
92201
JCFIREPROTECTION@V
ERIZON.NET
OWNER MODERN STRUCTURES LLC
PO BOX 1573
RANCHO
CA
92270
MIRAGE
Printed: Wednesday, February 26, 2020 9:17:26 AM 1 of 3 C SrsrEMS
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
FIRE SPRINKLER
SYSTEMS - SINGLE
101-0000-42421
0
$161.00
$161.00
1/21/20
R58468
1818
CHECK
JC FIRE PROTECTION
AHI
FAMILY DETACHED
FIRE SPRINKLER
SYSTEMS - SINGLE
101-0000-42420
0
$242.00
$242.00
1/21/20
R58468
1818
CHECK
JC FIRE PROTECTION
AHI
FAMILY DETACHED PC
Total Paid for FIRE FEES:
$403.00
$403.00
RECORDS
101-0000-42416
0
$10.00
$10.00
1/21/20
R58468
1818
CHECK
JC FIRE PROTECTION
AHI
MANAGEMENT FEE
Total Paid for RECORDS MANAGEMENT FEE:
$10.00
$10.00
TECHNOLOGY
502-0000-43611
0
$5.00
$5.00
1/21/20
R58468
1818
CHECK
JC FIRE PROTECTION
AHI
ENHANCEMENT FEE
Total Paid for TECHNOLOGY ENHANCEMENT FEE:
$5.00
$5.00
TOTALS:•0
$418.00
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR
SCHEDULED
COMPLETED
RESULT
REMARKS
NOTES
DATE
DATE
OVERHEAD ROUGH
KHET
2/27/2020
PIPING
OVERHEAD HYRO
KHET
2/27/2020
1. PARENT PROJECTS
REVIEW TYPE REVIEWER
SENT DATE
DUE DATE
RETURNED
REVIEWS
STATUS
REMARKS
NOTES
DATE
1ST PERMIT TECH (1 AARON
1/21/2020
1/22/2020
1/22/2020
COMPLETE
DAY) HICKSON
KOHL
1/21/2020
2/4/2020
2/11/2020
APPROVED
1ST FIRE (2 WK)
HETRICK
Printed: Wednesday, February 26, 2020 9:17:26 AM 2 of 3 .0"iImp'401
YSTEMS
Attachment Type l CREATED I OWNER
DOC 1 2/11/2020 1 KOHL HETRICK
DESCRIPTION
FSS2020-0013-
MODERN STRUCTURES -
APPR.pdf
PATHNAME
FSS2020-0013-
MODERN STRUCTURES -
APPR.pdf
SUBDIR f ETRAKIT ENABLED
Printed: Wednesday, February 26, 2020 9:17:26 AM 3 of 3 cow-YSTEMS
HARDENED HEX HEAD SELF HARDENED HEX HEAR SELF
THREADING SCREW THREADING SCREW
i
DOUBLE FASTENER STRAP 1YRE SINGLE FASTENER STRAP TYPE
HANGER HANGER
TYPICAL HANGER DETAILS
ALL HANGERS SHALL HE PER NFPA 130 & THE
CDDE REQUIREMENTS OF THE LOCAL AUTHORITY.
TABLE 4-5.2.2-1 MAXIMUM DISTANGE BETWEEN HANGERS (FT -IN
NOMINAL PIPE 3/4 1 1 1/4 1 1/2 2 2 1/2
SIZE (IN)
CPVC 5-6 6-0 5-6 7-0 8-0 9-0
MAXIMUM
END LINE
TABLE 1
SUPPORT SPACING DISTANCE
SPRINKLER HEAD DROP ELBOW
PINE SIZE
inches
SYSTEM PRESSURE
less than 100 psi
more than 100 psi
3/4
9
6
1
12
9
11/4
16
12
1 1 2-3
24
12
MAXIMUM
INLINE
TABLE 2
SUPPORT SPACING DISTANCE
SPRINKLER HEAD DROP TEE
PIPE SIZE
inches
SYSTEM PRESSURE
less than 100 psi
more than 100 psi
3/4
4
3
1
5
4
11/4
6
5
1 1 /2-3
7
7
SUPPORT SPACING AT SPRINKLERS
5LL IAULL 1 SEE TABLE 2
TINISHE D COUNG
UL LISTED PIPE CLAMP
USE ONLY UL U5T£D FA5TEh1ERS
SPRINKLER SPACING
MAXIMUM DISTANCE BETWEEN SPRINKLER IN ROOMS WITH ONE HEAD IS 18)i18
FEET (9 FEET OFF WALLS).
MAXIMU4 DISTANCE BETWEEN SPRINKLERS IN RDOMS WITH MORE THAN ONE
HEAD SS 18x16 FEET (8 FEET OFF WALLS).
MAXIMUM SPACING OF Q.R- SPRINKLERS IN GARAGE IS 130 SQUARE FEET,
SPRINKLERS SHAD_ BE LOCATED A MINIMUM OF B" FROM A WAIL (NFPA)
INSTALLATION NOTES
1- ALL C£SLIINGS THROUGHOUT RESIDENCE ARE HORIZONTAL (EXCEK WHERE NOTED).
2. ELEVATIONS AND DIMENSIONS SHDINN ON THESE DLtAW1NGS ARE NOMINAL ACPik
MEASUREMENTS MAY VARY AND SFLAI_L BE MODIFIF-D AS REQUIRED FOR FIELD CONDFTIOISIS.
3. PIPE LENGTHS SHOWN ARE CENTER TO CENTER.
4. INSULATION TO BE INSTALLED ABOVE ALL CPVC FIRE SPRINK FR NPING (13Y OTHERS)
NEW 1-1/4' SPRINKLER R€SER/D( ESTIC SHUT OFF
AND 6' ELECTRIC BELL
1-1/2" PVC U.G. WATER SUPPLY 85 F-T. FROM
METER TO RISER
4 J 1' WATER METER
(I ] WATER SUPPLY TO METER
NEW INSPECTORS TEST VALVE: IN ACCESS PANEL
CVWD SYSTEM DATA
DATE OBSERVED = 08-13-2019
INLET PRESSURE = 69.26
OUTLET PRESSURE = 38.36
ADJUSTED OUTLET PRESSURE = 34.52
SPARE HEAD BOX WILL BE PROVIIIED WTH AT LEAST ONE (1) SPARE SPRINKLER
HEAD OF EACH TYPE, SIZE AND ORIFICE INSTALLED IN THE SYSTEM.
TOR TO FIRE SPI#�KLER SYSTEM
6' ELECTRIC BELL (REi7)�
WRED TO FLOW SWITCH ----1 - ' /4" CPVC Pa PE
PRESSURE GAUGE TRANSITIN F1T7ING
r
PRESSURE RELIEF, TEST
do DRAIN VALVE
(CRAIN TO ATMOSPHERE) I MOUNTING P05T5
PROVIDE I SPARE FLQ1iY SRArITCH FS1
SPRINKLER HEAD FOR ::g fi F52
EACH TYPE INSTALLED 9
I -RUBBER FACED
I CHECK VALVE
PRV I '
ACCESS PANEL
DOMESTJC VALVE-
1—t/+" COPPER
DOM
COMBINATION
CONTROL ViALVE—
(AEOV►E GRADE)
-1/2' PVC u,G.
�� BUR
COPPER
1-1/4" RISER DETAIL
N.T.S.
HYDRAULIC
CALCULATION DATA
IBASEQ ON WATER P RESSURE CF
u 9.1) SOURCE
TWO HEAL] CALCULATION (AREA 1);
26.2 GPM 2l_97 PSI
BOTTOM OF RISER
0145 HFAD CALCULATION (AREA 2):
— 17 Q GPM 23.9 1 PSI
@ BOTTOM OF RISER
+1;
AREA I
CALL DESJGN INFORMATION
CALGULATkONARFA_ BA iI k Z
P SPRINKLERS CALCULATED 1. HEAD
AREA PER "EAD
..1.Riel8
HOSE WATERALLOWANCE
5 CPU
SYSTEM DEMAND
PSI AVAILAgL.E AT SOURCE
34.5
PSI REOUIREO AT XIJ FACE
27.8
GPM REQUIRED AT SOURCE
22.Q
PSI @ B-O-RISER
- -
23.8
GPM2 B_a.RiSER
r—
I 17.0
TO
FSY -S
A
AREA PER HEAD
] x
HOSE WATER ALLOWANCE
5 GPM
SYSTEM DEMAND
PSI AVAILABLE AT SOU POE
34-5
PSI fi QUIRED AT 50I.IRCE
28,8
GPM REQUIRED AT SOURCE
31.2
PSI* _B.O.RiSER
23-2
GPM + B4O.RISEfi _
26.2
Ar
CROSS SECTION SCALE: ' 3/16 1-0
SPRINKLERS SHALL BE LOCATED A MINIMUM OF 6" FROM A TALL
FIRE SPRINKLER PIPING PLAN
NFPA 13D
ri
A
SCAM: 3P I6 = 1-0
2
a
C.
4
GENERAL FIRE SPRINKLER NOTES
1. ALL DMISH, MATERIALS AND INSTAILLATION OF THE FFE SPRINIILFR SON SHALL
Ia MPLY KITH NFPA 13D AND LA QUINTA FK CODE RFQUIREirMS,
2. THE SCOPE DF WORK FOR THIS PROJECT I5 THE INST&UTION OF FIRE SPRIIVI4Lr-t5 AT
MEN SINGLE FAMILY RaDENCE (SEE PLANS).
3. ALI NEW M RHEAD PIPING SHALL BE BLA2MAWR CPC SPRINKLER PIPE AND
FITTINGS JOINED WttH UANUFAMRCIR PRMAIDED M-MDMNG PROCESS.
k ALL MATERLAL USED IN THE INSTALLATIDN OF THIS FIRE SPRkNKLER SYSTEM SHALL BE
NEW AND OF CURRE W ISSUE• ALL MATERIAL SHALL BE APPRpIVEp EfYY UNDERWRtTM
LABORATORIES (U.L) AND BE IN CONFORW4A U WITH THE MAST CURRENT ISSUE OF NFPA
13, 13D AND THE AiMIORRY HAVIINC JURISDICTION,
a. ALL MIEN PIPING SHALL BE HYDR067AT1CaAL.LY TEMD AS REQUIRED E3Y AHJ.
B ALL SPR NKLERS SHALL BE DESIGNED FM USE IN R£SIDFDTiAL OCCUPANCIES.
7. COATIONS AND DUDSIONS 5xOM ON THESE pF WINGS ARE NOMIWL ACTM
4FASU"f1+iT'S MAY VARY AND SI-I LL BE WODflED AS REQUIRED FOR RED CONDRIONS.
S. SPRINKLERS SHALL BE PERMM TO BE OEAfTTED IN SiaALL CLOSETS WHERE THE AREA
OF THE SPXE DOE'S NOT EXCEED 24 SO, FT. AND THE LW DIMENSION DDES NOT
EXCEED 3 FM
FIRE PROTECTION SYMBOLS
SYMBOL DESCRIPTION
NEW FIRE SPRINKLER {USER +W/
DOMESTIC SHUT OFF VALVE
NEW PENDENT SPRINKLER (SEE SPRINKLER L E ENC)
NEW PENDENT SPRINKLER (SEE SPRINKLER LEGEND)
NEW PIPING (CUT ON JOB)
PIPE HANGER LOCATIONS
6/110 VOLT ELECTRIC; BELL
(MRM BY ELECT. CONTRACTOR)
INSPECTORS IM VALVE 07-0 MIA)(. A.F.F. WITH 7/16
SMOOTH BORE, NON -CORROSIVE ORIFCE (TC DISCHARGE
OUTSIDE OE BUILDLNG)
XX HYDRAULIC CALCULATLON NODE (REFERENCE POINT)
09STRUCAON
D A
A ] (D — 19 Inches) B
D or = 30 Inches
MJNIMUM UiSTAMCE FROM EDGE
MINIMUM DISTANCE FROM F-DGE
Ht ti i SOklFIGE
OF SOURCE TO ORDINARY
OF SOURCE TO INTERMEDIATE
TEMPERATURE SPRNKLER
TEMPERATURESPgINKLER
INCHES
WCHIES
SIQE OF OPEK OR
36
12
RECESSES} FIREPLACE
FRONT CIF RECESSED
FIREPLACE
60
36
SIDE OF CEILING— OR
WALL —MOUNTED HOT
24
12
AIR DIFFUSERS
FRONT OF
WALL —MOUNTED HOT
36
iI9
AIR 011FUSERS
LIGHT F XTLIRE
3
0W-250W
LIGHT FIXTURE
250 W -- 499 W
12
6
XITCH N RANGE
18
9
LIGHTS, FANS AND DIFFUSER SMALL BE COORDINATED AROUND
SPRINKLER HEADS TO AVOID OBSTRUCTIONS AND HEAT SOURCE
DISTANCES IN ACCORDANCE WITH NFPA RECOMMENDATIONS
MAINTAIN 36" MINIMUM FROM THE
CENTER OF CEILING FANS & LIGHT
FIXTURES THAT ARE OBSTRUCTIONS
TO SPRI-NKLER DISCHARGE.
NFPA13D
AHJ USE ONLY
APPROVAL
RIvor0de Cbunty fire pa"ent
Of r
�-j
:I�tt
%� I� ��vak I;tdul , oad SUc-uilw0ung dim not
Permly ukolaLian, dcilnon, dmi5slw or faulty
Msmllanon of any regulr rn ixt5 of The 24 iar any
t-=, Q7i fiatwe'S. nemaln
acr_essibLe and exposed For inspecaan purpcses until
approved by tkte iP re Departn-ent.
<a
Q
LLJ
O
F
W
z
F
W
❑r
LLJ
k I
Li
LLj
a,_
x
w
u7
0
0
r*
or-
LLJ
Ld�N
im
1
M�N
1.*44
a
00
7-
52
72
LjLdw
z
z
z
z
•
1�
�
0
z
rn
U'
cc
W
(.)
uu
cc
o
Lu
ILu
CL
C1
L
41 o
L
o
I
c
0
�
0
rn
c
Q
c
0
LL n
L
LLJ
0
rjo
Lu
rr
J
Lu
w 0
LL
W
Lu
Ir
WL
z
0
LO
Iti
�
0
z
0
a+
n_
FIRE SPRINKI. ER'
PIPING PLAN
I
REVISIONS
A
r\
AREA CALCULATIONS
PER UNI
LIVABLE
5.-525
GARAGE
TOTAL SYSTEM AREA
4,031
PRESSURE AT SITE
08-27-19
59.26 PSI
DESIGNER CM
SCALE 3 16
= 1-0
CHECK BY FFM
FILE NUMBER 2C.003
APPROVAL LA QIUINTA
DATE
01--08-2020
DRAWING 140. FP
Sheet 1 of i Sheets
Molano, Angel ica@CALFI RE
Subject:
Location:
Start:
End:
Recurrence:
Meeting Status:
Organizer:
JAVIER 760-625-5908
FSS2020-0013 - THE QUARRY - OH SPRINKLER ROUGH/HYDRO
79540 TOM FAZIO LN
Thu 2/27/2020 11:00 AM
Thu 2/27/2020 12:00 PM
(none)
Meeting organizer
Hetrick, Kohl@CALFIRE
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 1 1HD CALC.SDF
JOB TITLE: AREA 1 1HD (18x18) (17 GPM)
WATER SUPPLY DATA
SOURCE STATIC
RESID.
FLOW
NODE PRESS.
PRESS.
@
TAG (PSI)
(PSI)
(GPM)
M (N/A)
34.5
(N/A)
AGGREGATE FLOW ANALYSIS:
AVAIL. TOTAL REQ'D
PRESS. @ DEMAND PRESS.
(PSI) (GPM) (PSI)
34.5 22.0 27.5
TOTAL
FLOW AT SOURCE
22.0
GPM
TOTAL
HOSE STREAM ALLOWANCE AT SOURCE
0.0
GPM
OTHER
HOSE STREAM ALLOWANCES
5.0
GPM
TOTAL
DISCHARGE FROM
ACTIVE SPRINKLERS
17.0
GPM
NODE ANALYSIS DATA
NODE
TAG ELEVATION
NODE TYPE
PRESSURE
DISCHARGE
(FT)
(PSI)
(GPM)
P1
11.8
K= 4.90
12.0
17.0
P2
11.8
- - - -
14.0
- -
P3
11.8
- - - --
14.0
- - -
1
12.2
- - - -
12.0
- - -
2
12.2
- - - -
13.8
- -
3
12.2
- - - -
13.8
- - -
A
12.2
-- - - -
13.4
- - -
B
13.2
- - - -
13.3
C
12.2
- - - -
13.8
- - -
D
12.2
- - - -
14.2
- - -
E
12.2
- - - -
14.9
- - -
TOR
12.2
- - - -
15.1
FS1
4.0
- - - -
18.8
FS2
4.0
-- - - -
21.8
- - -
BOR
0.5
- - - -
23.8
- - -
DOM
0.5
HOSE STREAM
24.2
5.0
UG
-3.0
- - - =
26.2
- -
M
-3.0
SOURCE
27.5
22.0
APPROVAL
Riverside County Fire Department
offke
Fiv:
Kohl He
The allproval of plans and speutications does not
nermit the violation, deletion, omission or faulty
installation of any rNuirements of Title 24 or any
Local Ordinances. Construction shall remain
uzesslble and exposed for inspection purposes untP
awrovt,d by the Fire Department.
SPRINKLER
SYSTEM
HYDRAULIC ANALYSIS
Page 2
DATE:
1/20/202003 QUARRY LOT
6 - LA
QUINTA
- CA -
JCP\AREA
1
1HD
CALC.SDF
JOB
TITLE:
AREA
1 1HD
(18xl8)
(17 GPM)
PIPE
DATA
PIPE
TAG
Q(GPM)
DIA(IN) LENGTH
PRESS.
END
ELEV,
NOZ.
PT
DISC. VEL(FPS)
HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI)
(GPM)
FL/FT
(PSI)
Pipe:
1
-17.0
1.101
PL
0.50
PF
0.2
Pi
11.8
4.9
12.0
17.0
5.7
150
FTG
E
PE
-0.2
1
12.2
0.0
12.0
0.0
0.050
TL
3.00
PV
Pipe:
2
0.0
1.101
PL
0.50
PF
0.0
P2
11.8
0.0
14.0
0.0
0.0
150
FTG
E
PE
-0.2
2
12.2
0.0
13.8
0.0
0.000
TL
3.00
PV
Pipe:
3
0.0
1.101
PL
0.50
PF
0.0
P3
11.8
0.0
14.0
0.0
0.0
150
FTG
T
PE
-0.2
3
12.2
0.0
13.8
0.0
0.000
TL
6.50
PV
Pipe:
4
-17.0
1.101
PL
18.25
PF
1.4
1
12.2
0.0
12.0
0.0
5.7
150
FTG
ETR
PE
0.0
A
12.2
0.0
13.4
0.0
0.050
TL
28.45
PV
Pipe:
5
0.0
1.101
PL
9.25
PF
0.0
2
12.2
0.0
13.8
0.0
0.0
150
FTG
R
PE
0.0
3
12.2
0.0
13.8
0.0
0.000
TL
10.95
PV
Pipe:
6
0.0
1.101
PL
0.50
PF
0.0
3
12.2
0.0
13.8
0.0
0.0
150
FTG
T
PE
0.0
C
12.2
0.0
13.8
0.0
0.000
TL
6.50
PV
Pipe:
7
-4.0
1.101
PL
61.75
PF
0.3
A
12.2
0.0
13.4
0.0
1.4
150
FTG
2ET4R
PE
-0.4
B
13.2
0.0
13.3
0.0
0.004
TL
79.55
PV
Pipe:
8
-4.0
1.101
PL
22.25
PF
0.1
B
13.2
0.0
13.3
0.0
1.4
150
FTG
2ET3R
PE
0.4
C
12.2
0.0
13.8
0.0
0.004
TL
38.35
PV
Pipe:
9
-4.0
1.101
PL
68.25
PF
0.3
C
12.2
0.0
13.8
0.0
1.4
150
FTG
4ET6R
PE
0.0
D
12.2
0.0
14.2
0.0
0.004
TL
94.45
PV
Pipe:
10
-13.0
1.101
PL
21.25
PF
0.8
A
12.2
0.0
13.4
0.0
4.4
150
FTG
2R
PE
0.0
D
12.2
0.0
14.2
0.0
0.030
TL
24.65
PV
Pipe:
11
-17.0
1.394
PL
33.75
PF
0.7
D
12.2
0.0
14.2
0.0
3.6
150
FTG
E3R
PE
0.0
E
12.2
0.0
14.9
0.0
0.016
TL
44.45
PV
Pipe:
12
-17.0
1.394
PL
10.25
PF
0.2
E
12.2
0.0
14.9
0.0
3.6
150
FTG
E
PE
0.0
TOR
12.2
0.0
15.1
0.0
0.016
TL
14.05
PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 1 1HD CALC.SDF
JOB TITLE: AREA 1 1HD (18xl8) (17 GPM)
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 13 -17.0 1.394 PL 8.25 PF 0.2
TOR 12.2 0.0 15.1 0.0 3.6 150 FTG R PE 3.6
FS1 4.0 0.0 18.8 0.0 0.016 TL 10.55 PV
Pipe: 14 FIXED PRESSURE LOSS DEVICE
FS2 4.0 0.0 21.8 0.0 3.0 psi, 17.0 gpm
FS1 4.0 0.0 18.8 0.0
Pipe: 15 -17.0 1.394 PL 3.50 PF 0.5
FS2 4.0 0.0 21.8 0.0 3.6 150 FTG 27.0 PE 1.5
BOR 0.5 0.0 23.8 0.0 0.016 TL 30.50 PV
Pipe: 16 -17.0 1.291 PL 2.00 PF 0.3
BOR 0.5 0.0 23.8 0.0 4.2 150 FTG 2ET PE 0.0
DOM 0.5 H.S. 24.2 5.0 0.023 TL 15.00 PV
Pipe: 17 -22.0 1.291 PL 3.00 PF 0.5
DOM 0.5 H.S. 24.2 5.0 5.4 150 FTG EC PE 1.5
UG -3.0 0.0 26.2 0.0 0.037 TL 14.00 PV
Pipe: 18 -22.0 1.598 PL 85.00 PF 1.2
UG -3.0 0.0 26.2 0.0 3.5 150 FTG 2E PE 0.0
M -3.0 SRCE 27.5 (N/A) 0.013 TL 93.00 PV
NOTES (HASS):
(1) Calculations were performed by the HASS 8.8 D computer program
in accordance with NFPA13 (2016)
under license no. 50081438 granted by
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
(2) The system has been calculated to provide an average
imbalance at each node of 0.005 gpm and a maximum
imbalance at any node of 0.090 gpm.
(3) Total pressure at each node is used in balancing the system.
Maximum water velocity is 5.7 ft/sec at pipe 4.
(4) Items listed in bold print on the cover sheet
are automatically transferred from the calculation report.
(5) Available pressure at source node M under full flow conditions is
34.52 psi with a flow of 25.20 gpm.
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 1 1HD CALC.SDF
JOB TITLE: AREA 1 1HD (18xl8) (17 GPM)
(6) PIPE FITTINGS TABLE
HASS Pipe Table Name: standard.pip
PAGE: F
MATERIAL: CPVC
HWC: 150
Diameter
Equivalent Fitting Lengths
in Feet
(in)
F
E
T R
K
C
G
F45
Ell
Tee RunT
Kplg
ChkVly
Gate
1.101
1.40
2.50
6.00 1.70
1.00
8.00
0.40
1.394
1.80
3.80
7.30 2.30
1.00
11.00
0.80
1.598
2.10
4.00
8.40 2.70
1.00
14.00
1.00
PAGE: M
MATERIAL: CT-M
HWC: 150
Diameter
Equivalent Fitting Lengths
in Feet
(in)
E
T
F R
K
C
G N
Ell
Tee 45-Ell
TeeRun
Kouplg
ChkVly
GatVly NPTee
1.291
3.00
7.00
1.00 2.00
0.50
8.00
0.00 7.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 1 1HD CALC.SDF
JOB TITLE: AREA 1 1HD (18xl8) (17 GPM)
WATER SUPPLY ANALYSIS
Fixed Source Pressure: 34.52 psi
50.
G
A 40.
U
G
E 1
30.0
P
R 2
E
S
S 20.0
U
R
E
{
p
s
i
10.0
9
-14.7
LEGEND
1 j Available pressure
34.52 psi @ 22.0 gpm
2 l Required pressure
27.46 psi @ 22.0 gpm
A. Source Supply Curve
B. System Demand Curve
600900 1200 1500 1800 2100 2400 2700 3000
FLOW (GPM)
Note: (1) Dashed Lines indicate extrapolated values from Test Results
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 1 1HD CALC.SDF
JOB TITLE: AREA 1 1HD (18x18) (17 GPM)
WATER SUPPLY CURVE
36+
I
I
33+
I
I
I
30+
I
I
X
27+
I
I
I
P 24+
R
E
S
S 21+
U I
R
E
18+
( I
P I
S
I 15+
I
I
I
12+
I
I
I
9+
I
I
I------------------------------
6+ LEGEND "
I"
X = Required Water Supply "
27.46 psi @ 22.0 gpm "
3+ "
I 0 = Available Water Supply "
34.52 psi @ 22.0 gpm "
I"
0++-+---+----+-----+------+--------+----------+---------+-----------+
8001200 1600 2000 2400 2800 3200 3600 4000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
dkA E: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 2 2HD CALC.SDF
JOB TITLE: AREA 2 2HD (16x16) (13 GPM)
WATER SUPPLY DATA
SOURCE
STATIC
RESID.
FLOW
AVAIL.
TOTAL
REQ'D
NODE
PRESS.
PRESS.
@
PRESS. @
DEMAND
PRESS.
TAG
(PSI)
(PSI)
(GPM)
(PSI)
(GPM)
(PSI)
M
(N/A)
34.5
(N/A)
34.5
31.2
28.8
(2.3
34.
Salo
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW
AT SOURCE
31.2 GPM
TOTAL HOSE
STREAM ALLOWANCE
AT SOURCE
0.0 GPM
OTHER HOSE
STREAM ALLOWANCES
5.0 GPM
TOTAL DISCHARGE FROM
ACTIVE
SPRINKLERS
26.2 GPM
NODE ANALYSIS DATA
NODE TAG
ELEVATION
NODE
TYPE
PRESSURE
DISCHARGE
(FT)
(PSI)
(GPM)
P1
11.8
-
- - -
11.1
P2
11.8
K=
4.90
7.0
13.0
P3
11.8
K=
4.90
7.3
13.2
1
12.2
-
- - -
10.9
2
12.2
-
-- - -
6.9
- - -
3
12.2
-
- - -
7.2
A
12.2
-
- - -
10.9
- - -
B
13.2
-
- - -
8.5
-- - -
C
12.2
-
- - -
8.0
- - -
D
12.2
-
- -
11.5
- - -
E
12.2
-
13.1
-- - -
TOR
12.2
-
- - -
13.6
FS1
4.0
-
- - -
17.6
- - -
FS2
4.0
-
- - -
20.6
- - -
BOR
0.5
--
- - -
23.2
- - -
DOM
0.5
HOSE
STREAM
23.9
5.0
UG
-3.0
-
- - -
26.5
- - -
M
-3.0
SOURCE
28.8
31.2
/21 i N! ✓H v--3e L S �j4f C
APPROVAL Cu�+' f t7G5�G ►.� N -j2 5 r
Riverside County Fire Department P
$y:
.-O o, " al 0
Kes c
The
2-�
approval of plans and specifications does not
perrnit the violation, deletion, omission or faulty
installatfon of any reiluirements of Titfe 24 or any
Local Ordinances. Construction shalt remain
accessible and exposed for inspection purposes until
approved by the fire De part3iient.
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
GATE: 1/20/202003 QUARRY LOT
6 - LA
QUINTA
- CA -
JCP\AREA 2
2HD
CALC.SDF
JOB
TITLE:
AREA
2 2HD
(16xl6)
(13 GPM)
PIPE
DATA
PIPE
TAG
Q(GPM)
DIA(IN) LENGTH
PRESS.
END
ELEV.
NOZ.
PT
DISC. VEL(FPS)
HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI)
(GPM)
FL/FT
(PSI)
Pipe:
1
0.0
1.101
PL
0.50
PF
0.0
P1
11.8
0.0
11.1
0.0
0.0
150
FTG
E
PE
-0.2
1
12.2
0.0
10.9
0.0
0.000
TL
3.00
PV
Pipe:
2
-13.0
1.101
PL
0.50
PF
0.1
P2
11.8
4.9
7.0
13.0
4.4
150
FTG
E
PE
-0.2
2
12.2
0.0
6.9
0.0
0.031
TL
3.00
PV
Pipe:
3
-13.2
1.101
PL
0.50
PF
0.2
P3
11.8
4.9
7.3
13.2
4.4
150
FTG
T
PE
-0.2
3
12.2
0.0
7.2
0.0
0.032
TL
6.50
PV
Pipe:
4
0.0
1.101
PL
18.25
PF
0.0
1
12.2
0.0
10.9
0.0
0.0
150
FTG
ETR
PE
0.0
A
12.2
0.0
10.9
0.0
0.000
TL
28.45
PV
Pipe:
5
-13.0
1.101
PL
9.25
PF
0.3
2
12.2
0.0
6.9
0.0
4.4
150
FTG
R
PE
0.0
3
12.2
0.0
7.2
0.0
0.031
TL
10.95
PV
Pipe:
6
-26.2
1.101
PL
0.50
PF
0.7
3
12.2
0.0
7.2
0.0
8.8
150
FTG
T
PE
0.0
C
12.2
0.0
8.0
0.0
0.112
TL
6.50
PV
Pipe:
7
11.7
1.101
PL
61.75
PF
2.0
A
12.2
0.0
10.9
0.0
3.9
150
FTG
2ET4R
PE
-0.4
B
13.2
0.0
8.5
0.0
0.025
TL
79.55
PV
Pipe:
8
11.7
1.101
PL
22.25
PF
1.0
B
13.2
0.0
8.5
0.0
3.9
150
FTG
2ET3R
PE
0.4
C
12.2
0.0
8.0
0.0
0.025
TL
38.35
PV
Pipe:
9
-14.6
1.101
PL
68.25
PF
3.6
C
12.2
0.0
8.0
0.0
4.9
150
FTG
4ET6R
PE
0.0
D
12.2
0.0
11.5
0.0
0.038
TL
94.45
PV
Pipe:
10
-11.7
1.101
PL
21.25
PF
0.6
A
12.2
0.0
10.9
0.0
3.9
150
FTG
2R
PE
0.0
D
12.2
0.0
11.5
0.0
0.025
TL
24.65
PV
Pipe:
11
-26.2
1.394
PL
33.75
PF
1.6
D
12.2
0.0
11.5
0.0
5.5
150
FTG
E3R
PE
0.0
E
12.2
0.0
13.1
0.0
0.036
TL
44.45
PV
Pipe:
12
-26.2
1.394
PL
10.25
PF
0.5
E
12.2
0.0
13.1
0.0
5.5
150
FTG
E
PE
0.0
TOR
12.2
0.0
13.6
0.0
0.036
TL
14.05
PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 2 2HD CALC.SDF
JOB TITLE: AREA 2 2HD (16x16) (13 GPM)
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 13 -26.2 1.394 PL 8.25 PF 0.4
TOR 12.2 0.0 13.6 0.0 5.5 150 FTG R PE 3.6
FS1 4.0 0.0 17.6 0.0 0.036 TL 10.55 PV
Pipe: 14 FIXED PRESSURE LOSS DEVICE
FS2 4.0 0.0 20.6 0.0 3.0 psi, 26.2 gpm
FS1 4.0 0.0 17.6 0.0
Pipe: 15 -26.2 1.394 PL 3.50 PF 1.1
FS2 4.0 0.0 20.6 0.0 5.5 150 FTG 27.0 PE 1.5
BOR 0.5 0.0 23.2 0.0 0.036 TL 30.50 PV
Pipe: 16 -26.2 1.291 PL 2.00 PF 0.8
BOR 0.5 0.0 23.2 0.0 6.4 150 FTG 2ET PE 0.0
DOM 0.5 H.S. 23.9 5.0 0.052 TL 15.00 PV
Pipe: 17 -31.2 1.291 PL 3.00 PF 1.0
DOM 0.5 H.S. 23.9 5.0 7.6 150 FTG EC PE 1.5
UG -3.0 0.0 26.5 0.0 0.071 TL 14.00 PV
Pipe: 18 -31.2 1.598 PL 85.00 PF 2.4
UG -3.0 0.0 26.5 0.0 5.0 150 FTG 2E PE 0.0
M -3.0 SRCE 28.8 (N/A) 0.025 TL 93.00 PV
NOTES (HASS):
(1) Calculations were performed by the HASS 8.8 D computer program
in accordance with NFPA13 (2016)
under license no. 50081438 granted by
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
(2) The system has been calculated to provide an average
imbalance at each node of 0.006 gpm and a maximum
imbalance at any node of 0.106 gpm.
(3) Total pressure at each node is used in balancing the system.
Maximum water velocity is 8.8 ft/sec at pipe 6.
(4) Items listed in bold print on the cover sheet
are automatically transferred from the calculation report.
(5) Available pressure at source node M under full flow conditions is
34.52 psi with a flow of 35.10 gpm.
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
6AtE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 2 2HD CALC.SDF
JOB TITLE: AREA 2 2HD (16xl6) (13 GPM)
(6) PIPE FITTINGS TABLE
HASS Pipe Table Name: standard.pip
PAGE: F
MATERIAL: CPVC
HWC: 150
Diameter
Equivalent
Fitting Lengths
in Feet
(in)
F
E
T R
K
C
G
F45
Ell
Tee RunT
Kplg
ChkVly
Gate
1.101
1.40
2.50
6.00 1.70
1.00
8.00
0.40
1.394
1.80
3.80
7.30 2.30
1.00
11.00
0.80
1.598
2.10
4.00
8.40 2.70
1.00
14.00
1.00
PAGE: M
MATERIAL: CT-M
HWC: 150
Diameter
Equivalent Fitting Lengths
in Feet
(in)
E
T
F R
K
C
G N
Ell
Tee 45-Ell
TeeRun
Kouplg
ChkVly
GatVly NPTee
1.291
3.00
7.00
1.00 2.00
0.50
8.00
0.00 7.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 2 2HD CALC.SDF
JOB TITLE: AREA 2 2HD (16xl6) (13 GPM)
WATER SUPPLY ANALYSIS
Fixed Source Pressure: 34.52 psi
.1 we
50.0
G
A 40.0
U
G
E 1
30.0
P
2
R
E
S
S 20.0
U
R
E
10.0
nmm�mn n,., �� n.ns,mmmmnrmm,.mnrmmnr.n ,� ,.omwarwumou,:mun oo.u,omu, ,M ,..r nu, i,omiumm, ummwm, i II
-14.7
LEGEND
L j Available pressure
34.52 psi @ 31.2 gpm
lRequired pressure
28.82 psi @ 31.2 gpm
A. Source Supply Curve
B. System Demand Curve
600900 1200 1500 1800 2100 2400 2700 3000
FLOW (GPM)
Note: (1) Dashed Lines indicate extrapolated values from Test Results
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE: 1/20/202003 QUARRY LOT 6 - LA QUINTA - CA - JCP\AREA 2 2HD CALC.SDF
JOB TITLE: AREA 2 2HD (16xl6) (13 GPM)
WATER SUPPLY CURVE
36+
I
I
33+
I
I
I
30+
1
X
1
27+
I
I
I
P 24+
R I
E I
S
S 21+
U
R
E
18+
( I
P
S
I 15+
I
I
I
12+
I
I
I
9+
I
I
6+
_____________________
LEGEND
I"
X = Required Water
Supply
"
I
28.82 psi @ 31.2
gpm
"
3+
"
I
0 = Available Water
Supply
"
I"
34.52 psi @ 31.2
gpm
"
0++-+---+----+-----+------+--------+--------+---------t-----------+
8001200 1600 2000
2400
2800 3200 3600 4000
FLOW (GPM)
Page 1 of 5
NJJQ FREEDOM° RESIDENTIAL
CONCEALED PENDENT
SPRINKLER VK494 (K4.9)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
DESCRIPTION
Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small
thermosensitive, glass -bulb residential sprinkler designed for installation on
concealed pipe systems where the appearance of a smooth ceiling is desired. The
orifice design, with a K-Factor of 4.9 (70.6 metric'), allows the sprinkler's efficient
use of available water supplies for the hydraulically designed fire -protection
system. The fast response glass bulb operating element and special deflector
characteristics meet the challenges of residential sprinkler standards.
The sprinkler is pre -assembled with a threaded adapter for installation with a
low -profile small -diameter cover assembly installed flush to the ceiling. The two-
piece design allows installation and testing of the sprinkler prior to installation
of the cover plate. The "push -on", "thread -off' design of the concealed cover
plate assembly allows easy installation of the cover plate after the system has
been tested and the ceiling finish has been applied, while also providing up to
1/2" (13 mm) of vertical adjustment. The cover assembly can be removed
and reinstalled, allowing temporary removal of ceiling panels without taking
the sprinkler system out of service or removing the sprinkler. The Electroless
Nickel PTFE (ENT) coating has been investigated for installation in corrosive
atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the
Approval Charts. The ENT finish is only available for the sprinkler assembly, the
cover plate is not plated.
2. LISTINGS AND APPROVALS
C&S UL Listed (C-UL-US-EU): Category VKKW
e6 Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing
requirements that must be followed.
TECHNICAL DATA
Specifications:
Minimum Operating Pressure: Refer to the Approval Chart.
Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to
500 psi (34.5 bar).
Thread size: 1/2" (15 mm) NPT
Nominal K-Factor: 4.9 U.S. (70.6 metric')
Glass -bulb fluid temperature rated to -65 °F (-55 °C)
WARNING: Cancer and Reproductive Hann-
www.P65Wamings.ca gov
Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the
metric K-factor shown by 10.0.
Material Standards:
Sprinkler Body: Brass UNS-C84400 or QM Brass
Deflector: Phosphor Bronze UNS-051000
Deflector Pins: Stainless Steel UNS-S30200
Button: Brass UNS-C36000
Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400
Compression Screw: 18-8 Stainless Steel
Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-051000
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating
Shipping Cap: Polyethylene
Cover Plate Materials:
Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400
Spring: Beryllium Nickel
Solder: Eutectic
Ordering Information: (Also refer to the current Viking price list.)
Viking Freedom-` Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately:
Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the
temperature rating to the sprinkler base part number.
Finish Suffix: Brass = A and ENT = JN
Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E
For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE.
Standard Cover Plates: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter),
or Base Part No. 15394 (square cover plate, 3-5/16")
Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No 21876 (2-3/4" diameter) or Base Part No.
21875 (3-5/16" diameter).
Form No. F_012116 18.10.11 Rev 18.1.P65 Replaces Form No. F_012116 Rev 18.1
(Added P65 Warning )
Page 2 of 5
f§11
FREEDOM® RESIDENTIAL
TECHNICAL DATA CONCEALED PENDENT
SPRINKLER VK494 (K4.9)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-946-9601 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover
temperature rating to the base part number:
Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B4B, Brushed
Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B
Temperature Suffix: 135 °F/57 °C =A
For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA.
Available Finishes And Temperature Ratings: Refer to Table 1.
Accessories: (Also refer to the Viking website.)
Sprinkler Wrenches":
A. Heavy Duty Part No. 14047W/B" (available since 2006), or
B. Head Cabinet Wrench Part No. 14031" (available since 2006)
C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007)
D. Optional Large Concealed Lover Plate Installer Tool Part No. 1486_� (available since 2007)
"Requires a +/V ratchet (not available from Viking). -Also optional for removal of the protective cap. Ideal for sprinkler cabinets.
Sprinkler Cabinet: Part No. 01731A (available since 1971)
4. INSTALLATION
Refer to appropriate NFPA Installation Standards
5. OPERATION
During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches,
releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand,
causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly.. Water flowing through the sprinkler
orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres-
sure at the sprinkler to extinguish or control the fire.
6. INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
7. AVAILABILITY
Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation
web site for the closest distributor or contact The Viking Corporation.
8. GUARANTEE
For details of warranty, refer to Viking's current list price schedule or contact Viking directly.
TABLE
1: AVAILABLE SPRINKLER
TEMPERATURE
RATINGS
■
Sprinkler
Sprinkler
Maximum
Temperature Rating
Cover
Large Square
Temperature
Nominal
Ambient
of the Cover
Plate
Cover Plate Cover Plate
Bulb Color
Classification
Temperature
Ceiling
Assembly
Base Part
Base Part Base Part
Rating'
Temperature'
(Required)'
Number'
Number' Number'
Ordinary
155 °F (68 °C)
100 °F (38 °C)
135 °F (57 °C)
13504 or
13642 or
15394
Red
21876'
21875'
Intermediate
200 °F (93 °C)
150 °F (65 °C)
135 °F (57 °C)
13504 or
13642 or
15394
Green
218766
21875'
Sprinkler Finishes:
Brass and
ENT
Cover Plate Finishes': Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted
White, Painted Ivory, or Painted Black
Corrosion Resistant Coatings': ENT
Footnotes
+• The sprinkler temperature rating is stamped on the deflector.
7 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having
Jurisdiction. Refer to specific installation standards.
Maximum ambient temperature for cover assembly is 100 °F (38 °C).
+• Part number shown is the base part number. For complete part number, refer to current Viking price list schedule.
5 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts These tests cannot and
do not represent all possible corrosive environments Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed
environment For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville
spring is exposed
e Stainless Steel versions are not available with any finishes or paint
Form No. F_012116 18.10.11 Rev 18.1. P65
Page 3 of 5
001ILFRE
EDOM® RESIDENTIAL
NCEALED PENDENT
RINKLER VK494 (K4.9)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
Approval Chart
Viking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler
For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to
current editions of NFPA 13, 13R or 13D
Sprinkler Base
SIN
NPT Thread Size
Nominal K-Factor
Maximum Water Wor-
Inches
mm
U.S.
T metric 2
Part Number
king Pressure
20759
VK494
1/2
15
4.9
70.6
175 psi (12 bar)
Max. Coverage
6
Flow
GPM
Pressure
Listings and
Minimum
Area
W X L
(LPM)
PSI (bar)
Deflector to
ns
Installation
Approvals'.5
Sin
Spacing
Ft. X Ft.
Ceiling
Type
Ft.
(m)
155 °F (68 °C), 200 °F (93 °C) Temperature
a 4L us 4
(m X m)
Rated Sprinklers
Err
12 X 12
13
7.0
(3.7 X 3.7)
(49.2)
(0.48)
14 X 14
13
7.0
(4.3 X 4.3)
(49.2)
(0.48)
Concealed with
Cover Plate
See Footnotes 7,9, 10,
8
16 X 16
13
7.0
(4.9 X 4.9)
(49.2)
(0.48)
Refer to Figure 2
Assembly.
See Footnote 8
& 11
(2.4)
18 X 18
17
12.0
(5.5 X 5.5)
(64.4)
(0.83)
20 X 20
20
16.7
(6.1 X 6.1)
(75.7)
(1.15)
Footnotes
+ Part number shown is the base part number. For complete part number, refer to current Viking price schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
,• This chart shows the listings and approvals available at the time of printing. Other approvals may be in process Check with the manufacturer for any additional approvals.
Refer also to Design Criteria
l Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union
6 Meets New York City requirements, effective July 1, 2008
6. For areas of coverage smaller than shown, use the "Flow" and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from
sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow' and "Pressure" used.
7. Cover Temperature Rating is 135 °F (57 °C). Cover Part No 135041, 13642+ (large diameter), or 15394+ (square cover plate).
6. Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint.
Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly.
Refer to Figure 3.
e. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or
Painted Black 6
+o•C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT)
++. Stainless Steel Cover plate temperature rating is 135 "F (57 °C). Stainless Steel Cover Part Numbers: 21876+ and 21875+ (large diameter).
Form No. F_012116 18.10.11 Rev 18.1.P65
Page 4 of 5
FREEDOM® RESIDENTIAL
A A • CONCEALED PENDENT
SPRINKLER VK494 (K4.9)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
DESIGN CRITERIA
(Atso refer to the Approval Chart an page 3.)
UL Listing Requirements, 1Q- L-11-E111:
When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover-
age and minimum water supply requirements shown in the Approval Chart.
For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum
required discharge from each of the four sprinklers is to be the greater of the following:
• The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or
• Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13.
• Minimum distance between residential sprinklers: 8 ft. (2.4 m).
NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only.
IMPORTANT: Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation.
Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in-
stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar
Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever
applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities
Having Jurisdiction.
Sprinkler and Adapter Assembly
• Protective cap removed
• Use wrench 14047W/B**
r Sprinkler Wrench
Part No. 14047W/B**
Step 1:
Carefully slide the
wrench sideways around
the deflector and pins
NEVER install the sprinkler by applying the installation
wrench across the frame arms. DO NOT overtighten.
Use only the designated sprinkler wrenches, Viking
Part Numbers 14047W/B** or 14031**. A leak tight seal
should be achieved by turning the sprinkler clockwise
1 to 1-1/2 turns beyond finger tight.
2-1/4" (57 mm)
neter opening
sired in the
ing.
Step 2: t t
Carefully press the wrench upward and
turn slightly to ensure engagement with
the sprinkler wrench flats.
Sprinkler
wrench flat .
{{ Sprinkler
frame arms
� r
Figure 1: Sprinkler Installation and Proper Wrench Usage
** A 1/2" ratchet is required (Not available from Viking)
Form No. F_012116 18.10 11 Rev 18.1.P65
Page 5 of 5
FREEDOM° RESIDENTIAL
TECHNICAL DATA CONCEALED PENDENT
SPRINKLER VK494 (K4.9)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
1/2" (15 mm) NPT
N 0 -
2-9/16" (65 mm)
Maximum
NOTE: Upon sprinkler activation, the deflector descends
to approximately 13116" (21 mm) below the sprinkler body.
2-1/16" (52 mm)
Minimum
q � �
2-3/4" (70 mm) or
3-5/16" (84 mm)
Figure 2: Sprinkler Dimensions and Cover Installation
QQ�\gyp CUS 7-0 o
a �2
O c�
U� O
MS
All custom color painted cover plates will have an
identifying label affixed to the inside of the cover that
indicates the custom color and will have a representative
sample (a paint dot) of the paint on the label
Figure 3: Identification of Custom Paint for Concealed Covers
-.
3-5/16" (84 mm)
Figure 4: Square Cover Assembly 15394
Form No F-012116 18 10.11 Rev 18.1.P65 Replaces Form No. F_012116 Rev 18.1
(Added P65 Warning.)
N11KINGA a
Page 1 of 5
MICROFAST®
QUICK RESPONSE
PENDENT SPRINKLER
VK331 dK41%
The Viking Corporation, 210 N Industrial Parr Drive, Hastings MI 49058
Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax, 269418-1gg0 Entail: techsvcs@vikingcorp.com
I. DESCRIPTION
The Viking Microfaste Quick Response Pendent Sprinkler VK331 Is a small ther-
mosensitive glass bulb spray sprinkler available with various finishes and tem-
perature ratings to meet design requirements. The special Polyester and PTFE
addition, these coatings have been investigated for installation in corcoatings can be used in decorative applications where colors are desired. In
rosive atmos-
pheres and are I:stedlapproved as corrosion resistant as indicated in the Approval
Charts.
2. LISTINGS AND APPROVALS
COw cULus Listed: Category VNIV
Refer to Approval Chart 1 and Design Criteria cULus Listing requirements.
3. TECHNICAL DATA
Specifications:
Minimum Operating Pressure: 7 psi (0.5 bar)
Rated to 250 psi (17 bar) water working pressure
Factory tested hydrostatically to 500 psi (34.5 bar)
Thread size: 112" NPT, 15 mm BSP
Nominal K-Factor; 4.2 U.S. (57 metric")
Glass-bu!b fluid temperature rated to -65 OF (-55 °C)
Overaii Length: 2-114" (58 mm)
Material ftridards:
Frame Casting: Brass UI,,[S-C84400
Deflector: Brass UN-CS6000 000
Bushing; Brass UN5-C3$Viking Technical Data may be found on
Bush
Bulb: Glass, nominal 3 mm diameter The Viking eonponstion's W%b site at
Belleville Spring Sealing Assembly; Nickel Alloy, coated on both sides with The Web eke may Include a more recent
PTFE Tape
Screw: Brass UNS-C36000 edition of this Technical Data Page.
Pip Cap and Insert Assembly: Copper L1NS-C11000 and Stainless Steel UNS-
S30400
For PTFE Coo i ' Belleville Spring -Exposed, Screw Nickel Plated, Pip Cap-PTFE Coated
F Polye :ar Coated Sprinklers: Belleville Spring -Exposed
Ordering information. (Also refer to the current Viking price list.)
Order Viking Micrvfast' Quick Response Pendent Sprinkler VK331 by first adding the appropriate suffer for the sprinkler finish and
then the appropriate suffix for the temperature rating to the sprinkler base part number.
Finish Suffix: Brass = A, Chrome = F, White Polyester = M-NV, Black Polyester = M-IB, and Black PTFE = N
Temperature Suffix: 135 OF (68 `C) = A, 155 OF (68 *C) = B, 175 °F (79 "C) = D, 200 OF (93 °C) = E, 286 OF (141 °C) = G
For example, sprinkler VK331 with a Brass frnish and a 155 "F (68 °C) temperature rating = Part No. 06720BAB
Available Finishers And Temperature Ratings: Refer to Table 1.
Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.)
SPrinider Wrenches:
A. Standard Wrench: Part No. 10895W113 (available since 2000).
B. Wrench for Recessed Pendent Sprinklers: Part: No. 16()36W18*" (available since 2011)
C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool, Part No. 15915 (available since 2010)
A %" ratchet is required (not available from Viking).
' Allows use from the floor by attaching a length of V diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F 051808.
Sprinkler Cabinets:
A. Six -head capacity: Part No. 01724A (available since 1971)
B. Twelve -head capacity. Part No. 01725A (available since 1971)
Form No. F 061814 Rev 14.1
(New page for VK331)
Page 2 of 5
MICROFAST®
QUICK RESPONSE
`- ' PENDENT SPRINKLER
y VK331 (K4.2)
The Viking Corporation, 210 N industrial Park Drive, Hastings 49068
Telephone: 269-945-9601 Technical Services: 877 384-5464 Fax: i
2 9-818-1680 Email- techev
cs@vlkingcorp.com
4. INSTALLATION
Refer to appropriate NFPA Installation Standards.
S. OPERATION
During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and
sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern
to extinguish or control the fire.
6. INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
, 7. AVAILABILITY
_.-The Viking Microfase Quick Response Pendent Sprinider VK331 is available through a network of domestic and international dis-
tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.
S: GUARANTEE
For details of warranty, refer to Viking's current list price schedule or contact Viking directly.
Wrench Flat
Protective Sprinkler
Figure 1: Standard Sprinkler Wrench 10896W/B
Form No. F_061814 Rev 14.1
Cap
Page 3 of 5
® MICROFAST®
. QUICK RESPONSE
PENDENT SPRINKLER
VK331 (K4.2)
VikingThe
Telephone: 269-945-9501 Technical Services: 877 384-5494 Fax: 289-818- 680 Email: tochavcs@vlkfngcorp.com � gcorp.com
S +riri'dar T n¢e tztra
S' -
,
mum Z baImit
Temp re Rating, Coiling Terrrperaturez
Sulb Color
Ordinary
135 °F (57 °C) 100 OF (38 °C)
Orange
Ordinary
165 °F (68 °C) 100 °F (38 °C)
Red
Intermediate
175 °F (79 °C) 150 °F (65 °C)
Yellow
Intermediate
200 °F (93 °C) 150 °F {65 °C)
Green
High
286 °F (141 °C) 225 °F (107 -C)
Blue
Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and Black PTFE
Corrosion -Resistant Coating83: White Polyester, Black Polyester, and Black PTFE
Footnotes
' The sprinkler temperature rating is stamped on the deflector,
' Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.
-RUer to specific installation standards.
'The -corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These
tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compat-
ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only.
—Note that the spring is exposed on sprinklers with Polyester and PTFE coatings.
` J
,,Sprinkler wrench 16036W/
for recessed pendent
sprinklers
" A 1/21, ratchet is requin
(not available from Vikin4
-
_t6l�
Carefully slide the wrench sideways around
the protective cap, ensuring engagement witl
the sprinkler wrench flats
Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers
Form No. F_061814 Rev 14.1
Page 4 of 5
NJ1VJW4J a
MICROFAST'1
QUICK RESPONSE
PENDENT SPRINKLER
VK331 (K4.2)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services: 877-384-6464 Fax: 269-818-1680 Email: tachsvcs@vikingcorp.com
Base
Part SIN
Number'
- (UL)
Tina Viking WC!—ofa----t` QEdCk Response Pendent
-Sprinkler VK331
maximum17- Psi o2 13ar)1l5iVp
Sprinkler Thread Size Nominal K-Factor Overall Length
Style
NPT I BSP I U.S.
06720E VK331 Pendent 1/2" 15 mm 4.2
Approved Temperature Ratings
A- 135 IF (57 °C), 155 IF (68 °C), 175 IF (79
'C), 200 IF (93 °C), 286 IF (141 °C)
B'�- 135 IF (57 °C), 155 IF (58 'C), 175 IF (79
IC), and 200 IF (93 °C)
metric I inches I mm
57 1 2-1/4
Approved Finishes
1 - Brass, Chrome, White
Polyester5A, Black Polyes-
ter5.6, and Black PTFE6
,�
A ) EUWALQ,,,, rar,aas ,en,,3
Listings and Approvals'
(Refer also to Design Criteria.)
cULLW I VdS I LPCB
58 A1X, B1Y I -- I — _
Approved Escutcheons
X - Standard surface -mounted escutcheon or the
Viking Micromatl& Model F-1 Adjustable Escutcheon
Y - Standard surface -mounted escutcheon or the
Viking Microfas? Model F-1 Adjustable Escutcheon, or
recessed with the Viking Micromati& Model E-1, E-2, or
E-3 Recessed Escutcheon
Footnotes
Base part number shown. For complete part number, refer to Viking's current price schedule.
Metric K-factor measurement shown is when pressure is measured in Bar. When pressure Is measured in kPa, divide the metric K-factor shown by
10.0.
3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process.
Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada.
s cULus Listed as corrosion -resistant.
e Other colors are available on request with the same Listings and Approvals as the standard colors.
DESM IQTT €A -
(Alsb refb: to Appro►af Ci,,art 7 above.)
-s es n� R,g9l��me:�,s•
The Viking Microfast® Quick Response Pendent Sprinkler VK331 is cULus Listed as indicated in the Approval Chart for installation in
accordance with the latest edition of NFPA 13 for standard spray sprinklers.
- Small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically
calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where
piping is corrosion resistant or internally galvanized
• The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed.
IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page
QR1-3 for general care, installation, and maintenance Information. Viking sprinklers are to be Installed in accor-
dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS
or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,
whenever applicable.
Form No. F_061814 Rev 14.1
Page 5 of 5
N_11K1W4j a
MICROFASTO
QUICK RESPONSE
PENDENT SPRINKLER
_ VK331 (K4.2)
VikingThe Corporation, Industrial
Telephone: 269-945-9501 T chni alServices: 877 384- 464F Fax: 269-818- techsvcs@vikingcorp.com
Email: techsvcs
� gcorp.com
Ceiling Opening Size:
1/21' 2-516P' (58.7 mm) minimum
(15 mm) i 2-1/2" (63.5 mm) maximum
NPT
(54 mm)
2-114„�
(57 mm) 2ps T (38 mm)
mm)
(44.5 mm) (51 Min.
Max. ,
Installed with a standard Installed with a Microfast
1/8" surface -mounted NOW At maximum, adapter is
Model F-1 Adjustable exposed 112" (12.7 mm)from
escutcheon Escutcheon face of ceiling
Figure 3: Sprinkler Dimenslons with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon
Ceiling Opening Size:
2-516P' (58.7 mm) minimum
2-1/2" (63.5 mm) maximum
2-118" 2-1/81,
.A
(54 mm} (54 mm)
IT'1
M
i-314" -1/8" T 5 ♦1-1/8„
28.6 mm 2""
(44.5 mm) ( ) Min. (51 mm) i°. (2 Min.
Max. Max.
Installed with a Installed with a Model
Model E-1 Recessed E-2 Thread -on Recessed
Escutcheon Escutcheon
Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons
Form No. F_061814 Rev 14.1
(New page for VK331)
Fig. 28 - "Stand -Off" Hanger & Restrainer for
CPVC Plastic Pipe 0@USLISTED
Size Range — 3/4" through 2"
Material — Carbon Steel, Pre -Galvanized
Function — Designed to be used as a hanger and restrainer for CPVC piping where
the "stand-off" design will ease installation by eliminating the need for wood blocking.
Features: i.
• Flared edge design protects CPVC pipe from any rough or abrasive surfaces.
Unique twist and lock design holds pipe firmly in place and allows retrofit type B A
■ of installation. �(
• The "Stand -Off" design eliminates the need for wood block extension. C (+
■ Can be installed on horizontal or vertical piping regardless of mounting +
surface orientation.
• Attaches easily to wood structure with two hex head self -threading screws
furnished with product.
• Installs easily using rechargeable electrical driver with 5/16" extension socket
eliminating impact tool damage to pipe. .,
• Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling
tapping screws.
• UL Listed as a hanger and a restrainer for fire sprinkler piping.
Approvals — Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to
support automatic fire sprinkler systems. May be installed into wood using fasteners
supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type
screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satis-
fies the UL vertical restraint requirement where needed. UL Listed as a hanger and ver-
tical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed
Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper
installed screw when used as a hanger only. I +
Order by — Figure number and pipe size.
Pat. # 7,455,268, Pat. # 7,832,248
FIG.278
(Jj fiCCIUlfi_❑ FIG2M 1\2lh
's`�^ _ (2) REQUIRED
OFHANGER
Dimensions • Weights
HANGER & RESTRAINT Pipe HANGER APPLICATION APPLICATION Sze A B C Approx.
3/4 31/32 2 31/2 .180
1 35/16 23/1e 31/2 .210
11/4 35/8 23/a 31/2 .225
11/2 4 21/2 31/2 .310
FIG3e- 14 2 41/2 211/16 3% .340
FIG.28 F10.76 �
Fan
• I`♦
OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92679 • PH: 951.737.5599 • FAX: 951.737.0330
CUSTOMER SERVICE • 800.786 5266
www.talco.com
Pipe Clamps_
T
w
A
TOLCOTM' Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe
Size Range: Available in 3/4" (20mm) and 1" (25mm) pipe sizes
Material: Pre -Galvanized Steel
Function Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler
pipe. Provides double offset 11/2" (20mm) x 11/2" (20mm) from mounting surface. This design
will ease installation by eliminating the need for wood block extension and allow retro-fit
attachment of hanger to sprinkler pipe.
Features:
• Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not
required to be bent for listed installation.
• Offset edge eliminates abrasion.
■ Attaches easily to wood structure with two special #10 x 1 " hex head self -threading
screws furnished with product.
• Can be used as a single offset hanger by aligning "dimples" with top of mounting
surface and utilizing two fasteners in two of the three holes provided.
Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a
hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of
NFPA 13, 13R and 13D.
Finish: Pre -Galvanized
Order By: Part number and pipe size.
Patent Pending
Pipe Size Approx. Wt,/100
Pert No. in. (mm) lbs. (kg)
29-3/4 3/4' (20) 17.0 (7.7)
29-1 1" (25) 18.6 (8.4)
Double Offset
Single Offset
c& us
USTEO
(38.1mm)
(38.1mm)
J----------,
0
I
0
n
1.5"
�+ (38.1mm)
I
r------------
r1
I--- 1.5"---
(38.1 mm)
Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self -tapping
screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of
the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not
required for performance of the hanger / restrainer function.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Eaton 103 B-Line series Pipe Hangers & Supports
tqCC Fire & Building
Products
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500
BlazeMaster
CPVC Fire Sprinkler Pipe & Fittings
Submittal Sheet
General
Description
Tyco Fire & Building Products (TFBP)
BlazeMaster CPVC Pipe and Fittings
are designed exclusively for use in wet
pipe automatic fire sprinkler systems.
They are made from a specially devel-
oped thermoplastic compound com-
posed of post chlorinated polyvinyl
chloride (CPVC) resin and state of the
art additives. TFBP BlazeMaster
CPVC products are easier to install
than traditional steel pipe systems,
and at the same time, provide superior
heat resistance and strength as com-
pared to traditional CPVC and PVC
piping materials used in the plumbing
trade. Various adapters are available
to connect CPVC pipe to metallic pip-
ing. All female pipe thread adapters
have brass inserts for durability.
Grooved adapters connect directly to
grooved end valves and metallic pipe,
with flexible grooved end couplings.
WARNING
Tyco Fire & Building Products (TFBP)
BlazeMaster CPVC Pipe and Fittings
described herein must be installed and
maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities ha v-
ing jurisdiction. Failure to do so may
impair the performance of these de-
vices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
with any questions.
Technical
Data
Sizes
3/4" to 3"
Maximum Working Pressure
175 psi
Approvals
UL, FM, CUL, NSF, Dade County,
LPCB, MEA, and the City of Los Ange-
les. (Refer to IH-1900, Rev. 0, Janu-
ary 2005 "Installation Instruction &
Technical Handbook" for exact list-
ing/approval information.)
Manufacture Source
U.S.A.
Material
• Pipe: ASTM F442, SDR 13.5
• Fittings: ASTM F438 (Sch. 40) and
ASTM F439 (Sch. 80), ASTM F1970
Color
Orange
Aft
rapid response M
HOME FIRE SPRINKLER SYSTEM
BlazeMaster® is a registered trademark
of Noveon IP Holding Corp.
Page 1 of 6 JANUARY, 2006 TFP1915
Page 2 of 6
TFP1915
WATER
NOMINAL
AVERAGE
AVERAGE
WEIGHT
FILLED WEIGHT
FT OF PIPE
WEIGHT PER LIFT
SIZE
O.D.
I.D.
Ibs./ft.
Ibs.ffL
PER LIFT
lbs.
3/4"
1.050"
0.874"
0.18
0.44
7875
1339
V.
1.315"
1.101,
0.26
0.67
5040
1320
1-1 /4"
1.660"
1.394"
0.42
1.08
2835
1191
1-1/2"
1.900"
1.598"
0.54
1.41
2205
1213
2"
2.375"
2.003"
084
2.20
1260
1084
2-1/2"
2.875"
2.423"
1.26
3.26
1215
1531
3"
3.500"
2.952"
1.87
4.83
720
1344
Installation
Tyco Fire and Building Products
(TFBP) BlazeMaster CPVC Pipe and
Fittings are to be installed in accord-
ance with IH-1900, Rev. 0, January
2005 "Installation Instruction & Techni-
cal Handbook".
FIGURE 1 — PIPE DIMENSIONS
Care and
Maintenance
The owner is responsible for the in-
spection, testing, and maintenance of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any
authority having jurisdiction. The in-
stalling contractor or product manufac-
turer should be contacted relative to
any questions.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service in accordance with
local requirements and/or national
codes.
NOTES
Before closing a fire protection system
control valve for inspection or mainte-
nance work on the fire protection sys-
tem that it controls, permission to shut
down the affected fire protection sys-
tem must first be obtained from the
proper authorities and all personnel
who may be affected by this action
must be notified.
After placing a fire protection system
in service, notify the proper authorities
and advise those responsible for moni-
toring proprietary and/or central sta-
tion alarms.
TFP191 5
Page 3 of 6
FITTING
PART
NOMINAL SIZE
NOMINAL TAKE-OUT
SCHD.
WEIGHT
TYPE
NUMBER
(T/O)
(lb.)
TEE
80000
3/4"
5/8"
40
0.11
T/O
80001
1°
11/16"
40
0.19
4-
i
80002
1-1 /4"
7/8"
40
0.26
80003
1-1/2"
1-1/16"
80
0.51
80004
2"
1-3/8"
80
0.90
80005
2-1/2"
1-9/16"
80
1.59
T/O
T/O
80006
3"
1-13/16"
80
2.41
XxYxZ
X
Y
Z
3/4" x 3/4" x 1"
3/4"
3/4"
5/8"
80132
40
0.14
80133
1" x 3/4" x 3/4"
9/16"
9/16"
3/4"
40
0.14
80134
1 " x 3/4" x 1"
3/4"
11 A 6"
3/4"
40
0.17
80260
1" x 1" x 3/4"
5/8"
5/8"
13/16"
40
0.16
80135
1-1 /4" x 1 " x 3/4"
5/8"
5/8"
15/16"
40
0.21
80136
1-1/4" x 1" x 1"
3/4"
3/4"
15/16"
40
0.22
80137
1-1/4" x 1" x 1-1/4"
15/16"
15/16"
7/8"
40
Q26
REDUCING TEE
80261
1-1 /4" x 1-1 /4" x 3/4"
5/8"
5/8"
7/8"
40
0-23
80262
1-1 /4" x 1-1 /4" x 1"
3/4"
3/4"
7/8"
40
0.26
Z
80138
1-1/4" x 1-1/4" x 1-1/2"
1"
V.
1"
80
0.43
T/O
80140
1-1/2" x 1-1/4" x 3/4"
9/16"
9/16"
1"
80
0.36
80141
1-1/2" x 1-1 /4" x 1"
9116"
9/16"
1-1116"
80
0.38
80263
80264
1-1/2" x 1-1/2" x 3/4"
1-1/2" x 1-1/2" x 1"
9/16"
9/16"
9/16"
9/16"
1"
1-1/16"
80
80
0.36
0.38
X Y
!!!T/O
80275
1-1/2" x 1-1/2" x 1-1 /4"
7/8"
7/8"
ill
80
0.45
T/O
80265
2" x 2" x 3/4"
3/4"
3/4"
1-3/8"
80
0.61
80266
2" x 2" x 1"
7/8"
7/8"
1-3/8"
80
0.66
80274
2" x 2" x 1-1 /4"
1-1 /16"
1-1 /16"
1-3/8"
80
0.74
80267
2" x 2" x 1-1/2"
1-1/8"
1-1/8"
1-3/8"
80
0.78
80271
2-1/2" x 2-1/2" x 1"
1-9/16"
1-9/16"
1-9/16"
80
1.43
80272
2-1/2" x 2-1/2" x 1-1 /4"
1-9/16"
1-9/16"
1-9/16"
80
1.46
80273
2-1/2" x 2-1/2" x 1-1/2"
1-9/16"
1-9/16"
1-9/16"
80
1.48
80276
2-1/2" x 2-1/2" x 2"
1-9/16"
1-9/16"
1-9/16"
80
1.50
80270
3" x 3" x 1-1/2"
1-13/16"
1-13/16"
1-13/16"
80
2.28
80268
3" x 3" x 2"
1-13/16"
1-13116"
1-3/4"
80
2.25
80269
3" x 3" x 2-1/2"
1-13/16"
1-13/16"
1-13116"
80
2.44
CROSS & REDUCING
CROSS
80009
3/4"
9/16"
40
0.13
T/O
80010
1"
11/16"
40
0.23
80011
1-1/4"
15/16"
40
0.34
80012
1-1/2"
1-1 /16"
80
0.67
80013
2"
1-5/16"
80
1.00
80014
2-1/2"
1-9/16"
80
1.91
T/O
80008
3"
1-13/16"
80
2.89
80015
1" x 1" x 3/4" x 3/4"
7/8"
40
0.28
T/O
T/O
80025
3/4"
5/8"
40
0.09
90° ELBOW &
REDUCING ELBOW
80026
1"
3/4"
40
0.14
80027
1-1/4"
7/8"
40
0.21
X
80028
1-1/2"
1-1/16"
80
0.40
T/10
80029
2"
1-5/16"
80
079
80030
2-1/2"
1-9/16"
80
114
Y
80031
3"
1-13/16"
80
1.82
XxY
X
Y
T/O
80032
1" x 3/4"
11/16"
13/16"
40
FIGURE 2 - FITTING DIMENSIONS (Part 1 of 4)
Page 4 of 6
TFP1915
FITTING
PART
NOMINAL SIZE
NOMINAL TAKE-OUT
SCHD
WEIGHT
TYPE
NUMBER
(T/O)
.
(Ib•)
45° ELBOW
80050
3/4"
3/8"
40
0.08
T/O
80051
1"
3/8"
40
0,11
80052
1-1/4"
3/4"
40
0,20
80053
1-1/2"
1/2"
80
0.31
T/O
80054
2"
314"
80
0.56
80055
2-1/2"
13/16"
80
0.89
80056
3"
1"
80
1,19
80075
3/4"
1 /8"
40
0.07
COUPLING &
80076
1"
1/8"
40
0.11
REDUCING COUPLING
80077
1-1/4"
3/16"
40
0.12
80078
1-1/2"
3/16"
80
0.25
80079
2"
3/16"
80
0.38
80080
2-1/2"
1 /4"
80
0,67
- - T/O
80081
3"
3/16"
80
0.91
80220
1" x 3/4"
1/8"
40
0.08
80200
1"x3/4"
7/16"
40
0.04
80201
1-1/4" x 3/4"
1 /2"
40
0.11
80202
1-1/4" x 1"
5/16"
40
0.12
80203
1-1/2"x3/4"
5/8"
80
0,16
80204
1-1 /2" x 1 "
1 /2"
80
0.14
REDUCER BUSHING
80205
1-112" x 1-1/4"
3/8"
80
0.17
80206
2" x 3/4"
13/16"
80
0.27
80207
2" x 1 "
11 A 6"
80
0.26
80208
2" x 1-1 /4"
9/16"
80
0.24
80209
2" x 1-1 /2"
7/16"
80
0.19
-I T/O
80215
2-1/2" x 1"
15/16"
80
0.42
80214
2-1/2" x 1-114"
13/16"
80
0.45
80213
2-1/2" x 1-1/2"
11 /16"
80
0.46
80211
2-1/2" x 2"
5/8"
80
0.29
80210
3" x 2"
3/4"
80
0.72
80212
3" x 2-1/2"
112"
80
0.47
CAP
80100
3/4"
5/16"
40
0.04
80101
1"
3/8"
40
0.06
80102
1-1 /4"
7/16"
40
0,10
80103
1-1/2"
11 /16"
80
0.20
80104
2"
5/8"
80
0.31
80105
2-1/2"
7/8"
80
0.58
T/O -
80106
3"
1"
80
0.88
GROOVED
T/O
PIPE O.D.
COUPLING ADAPTER
80160
1-1/4" x 1-1/4" Groove
2-5/16"
1-1/4" (1,660")
40
0.78
I
80161
1-1/2" x 1-1/2" Groove
2-5/16"
1-1/2" (1.900")
80
0.95
PIPE
80162
2" x 2" Groove
2-5/16"
2" (2.375")
80
1.42
O.D.
80163
2-1/2" x 2-1/2" Groove
2-5/16"
2-112" (2,875")
80
2.28
80164
3" x 3" Groove
2-1/4"
3" (3.500")
80
3.00
T/O -i
80169
2-1/2" x 76,1 mm Groove
2-5/16"
76,1 mm (3.000")
80
2.28
FIGURE 2 - FITTING DIMENSIONS (Part 2 of 4)
TFP1915
Page 5 of 6
FITTING
PART
NOMINAL SIZE
NOMINAL TAKE-OUT
SCHD.
WEIGHT
TYPE
NUMBER
(T/O)
(lb.)
SPRINKLER HEAD
ADAPTER
80175E
3/4" x 1/2" NPT
7/16'
80
0.20
80176E
1 " x 1/2" NPT
7/16"
80
0.22
[;;
80175WL
3/4" x 1/2" NPT
7/16"
40
0.16
80179
1" x 3/4" NPT
13/16"
40
0.43
SPRINKLER HEAD
ADAPTER
80175W
3/4" x 1/2" NPT
1/2"
40
0.19
AT
80176W
1" x 1/2" NPT
1/2"
40
0.18
SPRINKLER HEAD
ADAPTER (SPIGOT)
80177L
3/4" x 1/2" NPT
112"
40
0.16
80178
1" x 1/2' NPT
9/16"
40
0.20
7T/080180
1"x 3/4"NPT
7/8"
40
0.40
FEMALE ADAPTER
80142
3/4" x 3/4" NPT
13/16"
40
0.41
80145
1' x 1" NPT
7/8"
40
0.63
80146
1-1/4" x 1-1/4" NPT
1-1/8'.
40
1.03
80147
1-1/2" x 1-1/2" NPT
1-3/8"
80
1.42
80148
2" x 2" NPT
1-11/16"
80
Z66
T/O
MALE ADAPTER
80157
3/4" x 3/4" NPT
1-5/16'
40
0.33
ro —I
80158
1' x 1" NPT
1-3/8"
40
0.56
xxYxZ
x
Y
Z
SPRINKLER HEAD
ADAPTER TEE
80250
3/4" x 3/4" x 1/2" NPT
9/16"
9/16"
1"
40
0.22
Z
80251
1" x 1" x 1/2" NPT
11/16"
11/16"
1-3/16"
40
0.29
T/O
80249
1" x 1" x 1" NPT
15/16"
15/16"
1-9/16"
40
0.73
80256
1-1/4" x 1" x 1/2" NPT
7/16"
9/16"
1-5/16"
40
0.30
80252
1-1/4" x 1-114" x 1/2" NPT
7/16"
7/16"
1-5/16"
40
0.31
4T/0i=T/,0
80257
1-1 /2" x 1-1 /4" x 1/2" NPT
1/2"
11 /16"
1-7/16"
80
0.43
x Y I
80254
1-1 /2" x 1-1 /2" x 1/2" NPT
1/2"
1/2"
1-7/16"
80
046
80258
2" x 1-112" x 1/2" NPT
1/2"
5/8"
1-11/16"
80
0.56
80253
2" x 2" x 1/2" NPT
1/2"
1/2"
1-11 /16"
80
0.62
FIGURE 2 — FITTING DIMENSIONS (Part 3 of 4)
Page 6 of 6
TFP1915
FITTING
TYPE
PART
NUMBER
NOMINAL SIZE
NOMINAL TAKE-OUT
(T/O)
SCHD.
WEIGHT
(Ib•)
BACK-TO-BACK TEE
X x Y x Z
X
Y, Z
x
T/O
I
Y
80459
1" x 1/2" NPT x 1/2" NPT
5/8"
1-5/16"
40
0.48
80460
1" x 1/2" NPT x 1/2" NPT
5/8"
1-3/16"
40
046
Z 1
F
T/O
BACK-TO-BACK CROSS
X x Y x Z x W
X, Y
Z, W
x
T/O
I
z
80462
80463
1"xi"x1/2"NPT x1/2"NPT
1" x 1" x 1/2" NPT x 1/2" NPT
5/8"
5/8"
1-3/16"
1-5/16"
40
40
046
047
WI
T/O
Y
T/O
T/0
SPRINKLER HEAD
X x Y
X
Y
ADAPTER 90° ELBOW
Y
O
80199
3/4" x 1/2" NPT
9/16"
1"
40
0.20
80198
1" x 1/2" NPT
3/4"
1-1/4"
40
0.26
rI
80196
1"x 3/4" NPT
1-1/16"
1-7/16"
40
0.26
FIGURE 2 — FITTING DIMENSIONS (Part 4 of 4)
Limited
Warranty
Products manufactured by Tyco Fire &
Building Products (TFBP) are war-
ranted solely to the original Buyer for
ten (10) years against defects in mate-
rial and workmanship when paid for
and properly installed and maintained
under normal use and service. This
warranty will expire ten (10) years
from date of shipment by TFBP. No
warranty is given for products or com-
ponents manufactured by companies
not affiliated by ownership with TFBP
or for products and components which
have been subject to misuse, improper
installation, corrosion, or which have
not been installed, maintained, modi-
fied or repaired in accordance with ap-
plicable Standards of the National Fire
Protection Association, and/or the
standards of any other Authorities
Having Jurisdiction. Materials found
by TFBP to be defective shall be either
repaired or replaced, at TFBP's sole
option. TFBP neither assumes, nor
authorizes any person to assume for it,
any other obligation in connection with
the sale of products or parts of prod-
ucts. TFBP shall not be responsible for
sprinkler system design errors or inac-
curate or incomplete information sup-
plied by Buyer or Buyer's repre-
sentatives.
In no event shall TFBP be liable, in
contract, tort, strict liability or under
any other legal theory, for incidental,
indirect, special or consequential dam-
ages, including but not limited to labor
charges, regardless of whether TFBP
was informed about the possibility of
such damages, and in no event shall
TFBP's liability exceed an amount
equal to the sales price.
The farpgnina warranty s_made In lieu
of any and all other_ warrantieg,_Px-
press or implied, inc[udinrg_Warrant ies
of merchantability and fitness for apar-
titular purpose.
This limited warranty sets forth the ex-
clusive remedy for claims based on
failure of or defect in products, materi-
als or components, whether the claim
is made in contract, tort, strict liability
or any other legal theory.
This warranty will apply to the full ex-
tent permitted by law. The invalidity, in
whole or part, of any portion of this
warranty will not affect the remainder.
TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446
►�rER
Residential Connection Charge Estimate
August 13, 2019
Customer Name:
Modern Structures, LLC
Phone No.
(949) 478-1476
Parcel No.
766-031-018
Geo.
06-07-29-1
Address:
79540 Tom Fazio Ln N, La Quinta LID: 664546
Block No.
Lot No.
6
Size of Lot: 20,M SCE. ft.
Tract No. 32117
Type of Service:
YP
R-1: Duplex:
Triplex:
Apts:
SWSC:
$
-
Acres: 0.4 6 SWSC: $0.00 /acre
WSBFC:
SCC:
Treatment: $2,436/edu
Collection: $2,415/edu
Meter:
$
400.00
Meter Size: inch
Meter surcharge:
$
2,479.00
Service size: inch
Service:
$
-
Meter & Service:
$
Backflow:
Other:
Sewer Lateral:
$ -
Total: $ 2,879.00
LANDSCAPE PLANS REQUIRED.
Per Acc# 692231-664546 a 3/4" meter exists. Meter paid on
MCR #88823. SCC, WSBFC & SWSC pd on MCR #88843.
PZ 19-10221
Technician: Ruben Montiel
Fees Approved by: '*44Date:
Information Supplied By Customer
CVWD System Data
Domestic Water Demand*
Service Connection**
Max. Flow= 5 gpm
Max. Flow*=
34.1
gpm
Min. Pressure= 20 psi
Inlet Pressure 1=
69.26
psi
Fire Sprinkler I]emand*
Outlet Pressure=
38.36
psi
Max. Flow= 34.1 gpm
Min. Pressure= 37.9 psi
Meter Size =
1
inch
System Type: 171
Service Size=
1
inch
Multi Stand Alone
1 Prior to Pressure Regulating Valve
** For Calculation Purposes- Service Connection Includes:
* CVWD USES WORST CASE CONDITION
Service Connection Pipe=L', Meter Stop, Meter, Check Valve & Shut Off Valve
Calculations:
USE 1 " METER
" SERVICE
Pz= Lower Quarry
Rv' p 69.26
> 60 psi
HGL= 194
' v� `Fl�l�ter= 7.15
RESA= 0
HL- tc.= 23.75
RES./HT= 0
C 5819Q N A7 38.36
> 37.9 psi
PROP. ELEV.= 34
* Max 34.10 GPM
Ps is OK
�q C10- Q� 1 0 C to provide service
F
r�0F
TRY: Fire Sprinkler Demand
CA��oved b L pp y: ,�- � _
Date:
The meter sizing is for plan check purposes only. The ultimate responsibility resides with the Engineer -of
ecord for the pro ject.
QaA ra
CAI.IFORNIA
DESIGN & DEVELOPMENT DEPARTMENT
78-49S Calle Tampico
La Quinta, California 92253
(760) 777-7125 / FAX (760) 777-7011
FIRE REVIEW APPLICATION
6 NEW ❑ TENANT IMPROVFMFNT
octal
PROJECT INFORMATION (Please Pdnt)
Project Name: (-qO-f Y LDT Sign: 'j��-�-
Site Address: 9- a 90 Tb M-Fa Zt D LN) Print: C� y -era
City & Zip: I vyicw Gj a �3 Project
Y
oao+�
JAN 2 1 2020 J
CITY OF LA QUINTA
DESIGN & DEVELOPMENT DEPARTMENT
PERMIT NO.
Description:
Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the
City's fire department, and the County designee serves as the City's fire chief. Applicant recognizes this
contracted a►ran ernent and shall comply with County Fire Department dire6ions
APPLICANT/CONTACT INFORMATION CONTRACTOR INFORMATION: Mamle as Applicant info
Applicant Name: A C ii�l_ y- C �'�Gt�Y1 Contractor #:
Contact Person: _ry vl C. l _Cal' 1\\DfC'( Contact Person:
c[ Mailing Address: /q - � v C Mailing Address:
City &Zip: 112C
ifo P s -Q City & Zip:
Phone Number: -) �aU -2f -MOed Fax Phone Number:
Fmnil-
Fmnil-
Fax
A. APPLICATION TYPE
FIRE SPRINKLER SYSTEM
STORAGE TANKS
❑ NEW COMMERCIAL/INDUSTRIAL
____________
❑ DISPENSERS ONLY
HOURLY@161/HR
HOURLY@161/HR
❑ 0-35,000 SQ FT
$670
❑ ABOVEGROUND —�
❑ 35,001-75,000 SQ FT
$791
SUPRESSION SYSTEM
❑ 75,001-120,000 SQ FT
$992
❑ HOOD & DUCT
$418
❑ 120,001 AND UP
$1234
❑ SPRAY BOOTH
HOURLY@161/HR
❑ TENANT IMPROVEMENTS - FIRE SPRINKLER
$418
❑ OTHER SUPRESSION SYSTEM
HOURLY@161/HR
RESIDENTIAL Sprinkler Systems
__________
❑ HAZMAT
HOURLY@161/HR
1-50 SPRINKLER HEADS
$418
MISC
❑ 51-100 SPRINKLER HEADS
$498
❑ HAZMAT
HOURLY@161/HR
❑ OVER 100 SPRINKLER HEADS
$579
❑ HIGH PILE RACK STORAGE
HOURLY@161/HR
❑ RESIDENTIAL - (EA) ADDITIONAL
$176
❑ PRIVATE FIRE MAINS
$901
❑ MULTI -FAMILY (3 OR MORE)
$590
❑ TECHNICAL REPORT RESEARCH
HOURLY@161/HR
FIRE ALARM SYSTEM
❑ FIRE PUMPS
$659
❑ COMMERCIAL - SPRINKLER MONITORING
$418
❑ STANDPIPE SYSTEMS
$579
❑ COMMERCIAL - FIRE ALARM SYSTEM
$1062
❑ WATER TANKS
$418
MASTER PLAN
❑ PYRO
$740
❑ MASTER PLAN
HOURLY@161/HR
❑ REVISION #
HOURLY@161/HR
❑ MASTER PLAN REVISION
HOURLY@161/HR
I
❑ OTHER
HOURLY@161/HR
E nch application type includes a Technology Enhancement Fee of $5 & Records Management Fee of $10 or $21 REVISED 10/Z/ZU19
*For permits billed at an hourly rate, these fees will be added at time of payment.
f
CAL FIRE - RIVERSIDE UNIT
RIVERSIDE COUNTY FIRE DEPARTMENT
SHAwN C. NEwmAN — FIRE CHIEF
OFFICE OF THE FIRE MARSHAL — LA QUINTA CAI.IFORMA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
February 11, 2020
JC Fire Protection
81705 De Oro Avenue
Indio, CA 92201
Re: Residential Fire Sprinkler Plan Review — Modern Structure @ The Quarry
FSS2020-0013 / 79540 TOM FAZIO LN NORTH, LA QUINTA, CA 92253
The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County
Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions.
Permanently marked identification signs shall be attached to all control valves.
The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff:
(a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal
operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the
potential to contact CPVC piping once insulation is installed.
(b) Final inspection
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist