FSS2020-0022ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 KATHY@JDMECHANIC AL.CO CONTRACTOR J D MECHANICAL FIRE INC 82579 FLEMING WAY SUITE D INDIO CA 92201 KATHY@JDMECHANIC AL.CO OWNER LIVIN ON THE EIGHTH, LLC CA 0 CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE KOHL HETRICK 8/17/2020 8/17/2020 As-builds uploaded by applicant to attachments. PUBLIC COUNTER VISIT AARON HICKSON 1/29/2020 1/29/2020 ADJUSTED FEE AS IT WAS INCORRECT ON FEE SCHEDULE PUBLIC COUNTER VISIT JACK LIMA 2/12/2020 2/12/2020 PERMIT ISSUED TO KATHY SLOAN. CONDITIONS Description: LIVIN ON THE EIGHTH, LLC / FIRE SPRINKLER / BRES2019-0147 Type: FIRE SPRINKLER Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 1/29/2020 AHI Parcel No: 767680052 Site Address: 53494 ROSS AVE LA QUINTA,CA 92253 Approved: 2/11/2020 KHET Subdivision: TR 33076-1 Block: Lot: 47 Issued: 2/12/2020 JLIM Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 8/19/2020 KHET Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Thursday, January 12, 2023 2:33:34 PM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0022 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 3/5/2020 3/5/2020 PARTIALLY APPROVED Partial -South side only OVERHEAD HYRO KHET 3/5/2020 3/5/2020 PARTIALLY APPROVED Partial -South side only OVERHEAD ROUGH PIPING KHET 4/13/2020 4/13/2020 APPROVED PARTIAL REMOTE VIDEO INSPECTION. THIS COVERED THE MASTER SUITE & GUEST SUITE SIDE OF THE HOUSE. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 8/26/20 WEB6088 517719 CREDIT J D MECHANICAL FIRE INC ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $241.00 $241.00 1/29/20 R58799 1782 CHECK J D MECHANICAL FIRE INC AHI FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 1/29/20 R58799 1782 CHECK J D MECHANICAL FIRE INC AHI Total Paid for FIRE FEES: $644.00 $644.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 1/29/20 R58799 1782 CHECK J D MECHANICAL FIRE INC AHI Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 1/29/20 R58799 1782 CHECK J D MECHANICAL FIRE INC AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$659.00 $659.00 Printed: Thursday, January 12, 2023 2:33:34 PM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0022 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/10/2020 ARMANDO MAGALLON PLAN SET - APPROVED FSS2020-0022 PLAN SET.pdf 0 DOC 8/17/2020 EtrakitContractor Lot 47 pdfSprinkler As Builds.pdf 1 DOC 12/9/2021 JOSE DELGADO Fire Review Application.pdf Fire Review Application.pdf 0 DOC 12/9/2021 JOSE DELGADO FSS2020-0022 - CALCULATIONS.pdf FSS2020-0022 - CALCULATIONS.pdf 0 DOC 12/9/2021 JOSE DELGADO FSS2020-0022 - CVWD RESIDENTIAL CONNECTION CHARGE ESTIMATE.pdf FSS2020-0022 - CVWD RESIDENTIAL CONNECTION CHARGE ESTIMATE.pdf 0 BOND INFORMATION OVERHEAD ROUGH PIPING KHET 4/13/2020 4/13/2020 APPROVED PARTIAL AS-BUILTS REQUIRED PRIOR TO FINAL INSPECTION. OVERHEAD HYRO KHET 4/13/2020 4/13/2020 APPROVED FINAL PARTIAL REMOTE VIDEO INSPECTION. THIS COVERED THE MASTER SUITE & GUEST SUITE SIDE OF THE HOUSE. FIRE FINAL**KHET 8/19/2020 8/19/2020 APPROVED PROCESSED AFTER FEES PAID REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 1/29/2020 1/30/2020 1/30/2020 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 1/29/2020 2/12/2020 2/11/2020 APPROVED PARENT PROJECTS Printed: Thursday, January 12, 2023 2:33:34 PM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0022 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/9/2021 JOSE DELGADO FSS2020-0022 -COA.pdf FSS2020-0022 -COA.pdf 0 Printed: Thursday, January 12, 2023 2:33:34 PM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0022 x;GARAGE x;MASTER SUITE x;OFFICE x;ENTRY COURTYARD x;KITCHEN x;BAR x;ENTRY x;CLOSET x;LAUNDRYx;MECH.x;BATH x;HALL x;TUB x;BATH x;DINNING x;DEN x;KID #2x;KID #1 x;GUEST x;CLOSET x;CLOSET x;CLOSET x;OUTDOOR LIVING x;SITTING x;HIS x;SITTING x;COVERED CAR PORT x;HER CLOSET x;GUEST SUITE x;A/V x;PANTRY x;POWDER x;POWDER x;KID x;CLOSET x;CLOSET x;BATH x;ELECT x;MASTER BATH x;SHOWER x;HALL x;VESTIBULE x;GUEST BATH 12'-0"12'-1" 10'-1" 10'-1" 10'-1" 12'-1"13'-1" 12'-1" 12'-1" 12'-1" 10'-1" 12'-1" 14'-1" 13'-1" 16'-1" 11'-1"11'-1" 16'-1" 12'-1"12'-1" 12'-1" 12'-1" 12'-1" 11'-1" 14'-1" 14'-1" 11'-1" 11'-1" 12'-1" 12'-1"12'-1" 11'-1" 11'-1" 12'-1"16'-1" 11'-1" 14'-1" 14'-1" 12'-4" 12'-1" 12'-1" 11'-1" x;W x;D SC SC SC SC SC SC SC SC SC N x;SINKx;SINK x;SINK x;FPx;FPx;FP x;FP x;FP x;FP x;FPx;FPFire Sprinkler Riser Detail 1" CPVC to supply fire sprinkler system TOR BOR Domestic Supply Check Flow Control 1" CPVC Flow Switch Note Wiring by Others 300psi Gage Sprinkler Box with Wrench & two Sprinkler Heads Each Type 1/2" Drain to Outside1"1"1" Potter Horn Strobe Wired by Others not to scale Module Must Connect to the Multi Station Smoke Alarm System and the Fire Sprinkler Flow Switch ( all wiring by others ) CPVC HANGERS NO SCALE TOLCO FIG. 24 DOUBLE-FASTENER SIDE-MOUNT HANGER (OR EQUAL) SELF-DRILLING HEX HEAD SCREW TOLCO FIG. 23 DOUBLE-FASTENER STRAP TYPE HANGER (OR EQUAL) TOLCO FIG. 28M OFFSET HANGER (OR EQUAL) TOLCO FIG. 22 SINGLE-FASTENER STRAP-TYPE HANGER (OR EQUAL) TOLCO FIG. 28 DOUBLE-FASTENER STAND-OFF HANGER (OR EQUAL) TOLCO FIG. 29 DOUBLE-FASTENER DOUBLE OFFSET HANGER (OR EQUAL) CPVC HANGER SPACING PIPE SIZE 11/4" 1" MAXIMUM SUPPORT SPACING 6'-6" 6'-0" 2"8'-0" 11/2"7'-0" INSPECTOR TEST DETAIL 5' 1" Ball Valve Access Panel (By Others) Exterior Wall of Building Inspector Test to Terminate in a Smooth Bore Corrosion Resistant Orfice With a Flow Equivalent to One Sprinkler NOTE: Access Panel Shall have sign Indicating Inspector Test RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD BEAM OR RAFTER WOOD SAMMY SUPERSCREW (Model GST20) 2x_ BLOCKING (TO BE SAME SIZE AS RAFTER) NAILED TO RAFTERS w/ (2) 10d NAILS EACH SIDE OF BLOCK. WOOD BEAM OR RAFTER WOOD BEAM OR RAFTER RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD SAMMY SIDEWINDER (Model SWG20) RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD BEAM OR RAFTER WOOD SAMMY SIDEWINDER (Model SWG20) 2x_ BLOCKING (TO BE SAME SIZE AS RAFTER) NAILED TO RAFTERS w/ (2) 10d NAILS EACH SIDE OF BLOCK. WOOD BEAM OR RAFTER WOOD BEAM OR RAFTER RING HANGER (TOLCO FIG. 200) 3/8" ALL-THREAD ROD PIPE WOOD SAMMY SUPERSCREW (Model GST20) TOLCO TOLCO 15' - 2"Supply Point Water Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 76.70 psi 58.85 psi 5000 GPM 0 GPM Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-1 R-3 2 Gpm/SqFt 512 SF Max SqFt 31.1914 GPM 38.8217 Psi 5 GPM 0 GPM BOR 8 TOR 7 6 9 4 5 WM DOM 1" 15' -6"1"5' -2 1/2"3/4"9' -4"1" 10' -10 1/2"3/4"1' -11"1" 4' -3 1/2"3/4"10' -1"3/4"5' -6"3/4" 6' -4 1/2"3/4"1' -1"3/4" 7' -1"3/4"1' -11"3/4"7' -5 1/2"3/4" 5' -7 1/2"3/4"1' -6"3/4"8' -6"3/4" 4' -3"3/4"1' -0"3/4"9' -0"1" 8' -11" 1" 10' -6 1/2"3/4"10' -1"3/4"5' -6"3/4" 6' -9"3/4"0' -10"3/4"2' -2"3/4"7' -7"3/4" 4' -5" 3/4" 1' -4 1/2"3/4"8' -6"3/4" 5' -2 1/2" 3/4" 1' -4 1/2"3/4"8' -6"3/4" 7' -0" 1" 0' -5 1/2" 1" 2' -2 1/2" 1" 2' -0" 1" 4' -2"3/4"12' -7"3/4" 6' -5 1/2" 3/4" 1' -0"3/4"8' -7 1/2"3/4" 3' -9"3/4" 1' -6"3/4"9' -9"3/4" 5' -11"3/4" 1' -6"3/4"9' -9"1" 5' -4"3/4"9' -5 1/2"3/4"13' -5 1/2"1" 0' -8" 1" 12' -8 1/2"3/4"7' -3 1/2"3/4"13' -7"3/4"11' -8 1/2"3/4"1' -10 1/2"3/4" 16' -5"1"6' -3 1/2"1"13' -7"1" 0' -7" 1" 12' -4" 1" 12' -8" 3/4" 1' -7 1/2" 1" 12' -8" 3/4" 1' -7 1/2"1"3' -7"1" 13' -1 1/2" 1" 7' -3" 1" 11' -3" 1" 1' -9" 3/4" 7' -3 1/2" 1" 10' -7 1/2"3/4"5' -7"3/4"5' -4 1/2"1" 12' -4 1/2"3/4"5' -4 1/2"3/4"5' -7"1" 12' -4 1/2" 1" 14' -9 1/2" 1" 1' -1 1/2"1"7' -5"1" 11' -1"1"4' -6"1" 3' -11 1/2" 1" 8' -0"3/4"6' -3 1/2"1" 1' -0" 3/4" 2' -8 1/2"1"8' -0"1" 11' -6 1/2"3/4"4' -5"3/4"8' -4"1" 13' -3"3/4"4' -5"1"8' -4"1" 0' -10" 1" 0' -10"1" 15' -10 1/2" 1" 2' -8 1/2"1"8' -0"3/4" 5' -7" 3/4" 3' -4 1/2" 3/4" 4' -4"3/4"6' -4 1/2"3/4"4' -4 1/2"1" 2' -0"3/4"6' -4 1/2"3/4" 4' -4 1/2" 1" 8' -5"3/4" 2' -11 1/2" 1" 14' -7"3/4"5' -3"3/4"3' -7"3/4" 5' -3" 3/4" 1' -7 1/2"1"15' -10"1"13' -5 1/2"1"9' -5 1/2"3/4" 1' -7 1/2"3/4"7' -3 1/2"3/4"13' -7"3/4"13' -7"3/4"6' -3 1/2"3/4"13' -7"3/4"3' -5"3/4"3' -4"3/4"1' -11"1"1' -11"1"1' -11"1"10' -9"3/4"5' -2 1/2"3/4"12' -2"3/4"5' -2 1/2"3/4"12' -2"1" 1' -6 1/2" 2" 6' -10"2"33' -0"3/4" 4' -1" 1" 8' -10" 1" 5' -4" 3/4" 5' -3"2" Underground Copper By Others1" Fire Riser 3/4"12' -2"16' - 0"3/4"13' -7"11' - 8"11' - 9" Inspectors Test Valve GENERAL NOTES 1.General: All materials and devices shall conform to 2019 NFPA 13D standards. Installation shall conform to all applcable State and Local Codes. 2.Scope of Work: Install a new Residential Fire Protection System. 3.Piping: All overhead pipe and fittings shall be CPVC unless otherwise noted. 4.Design: NFPA 13D 2019 Edition and CFC Chapter 80 Standards. 5.System Demand @ Source. Two Sprinklers Flowing (16X16 Spacing): 31.19 gpm @ _38.82__psi ( AREA ) 6.Water Supply Data: Water is supplied from public water main in street. Static Pressure: 76.7 Information Source: CVWD 7.Sprinkler Head Spacing and Installation Requirements:Sprinklers shall not be located Closer than 8'-0" apart where there is no intervening obstruction. Sprinklers near potential obstruction shall be located per manufactures instructions. 8.Piping Supports: Piping shall be supported and restrained in conformance with local plumbing codes and CPVC manufactures instructions . Eachpipe section that supplies a drop to a sprinkler shall be secured no more than 12" from the drop to prevent laterial and vertical movement. 9.Pipe lenghts are approximate for hydraulic calculation and plan review purposes only. 10.The owner shall furnish sufficant heat in all areas to prevent freezingof pipe. 11.Waterflow Switch and Alarm: By Others a. A dedicated electrical circuit with a circuit breaker lock shall be provided for waterflow horn/strobes. b. An approved audible sprinkler waterflow alarm shall be visible from the street. The device shall be listed for outdoor use. An approved sign shall be placed at or near the device stating, SPRINKLER FIRE ALARM - WHEN ALARM SOUNDS CALL 911 c. An approved audible sprinkler waterflow alarm module shall be conected to the smoke detectors to alert occupants shall be provided. Fire Department Notes NFPA 13D 2019 A. The installation of new fire sprinkler systems or modifications to existing systems shall comply with the following: NFPA 13D 2019 CBC 2019 CFC 2019 Local Municipal Codes Requirements of the AHJ All Manufacture Installation Guidelines Note: When conflict arrises between existing codes and standards, the most stringent shall apply. B. The Fire Department Shall require the following inspections and tests. 1. Overhead installation and hydrostatic test, ( prior to cover ). a. Normal opperating pressure when no FDC is installed. b. 200psi when FDC is required. c. Two hour minimum. 2. Final sprinkler and underground, ( prior to building final ). a. All inspections shall be scheduled by the contractor of record. b. Inspections shall be scheduled 24 hours in advance. jd@jdmechanical.co Scale Project number Date Drawn by Checked by JD Mechanical Fire Inc.82579 Fleming Way Suite DIndio Ca. 92201(760) 775-6220JD Mechanical Fire Inc. C-16 # 1020141 As indicated 8/14/2020 4:35:08 PMFP-2 Sprinkler Plan Project Number Issue Date Author Checker No. Description Date MADISON LOT 4753494 Ross AveLa Quinta, Ca. 900631/8" = 1'-0"1 Sprinkler Plan Sprinkler Schedule K-Factor Manufacturer Description Temperature Rating Count 4.9 SENJU Senju SS8464 Conceled Pendent Light Hazard Quick Response1/2 Orifice 3mm GB 162 °F 91 4.2 Tyco Tyco TY2231 Recessed Pendent Light Hazard Quick Response1/2 Orifice 3mm GB 175 °F 9