FSS2020-0030ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES Description: NEUFIELD / FIRE SPRINKLERS / BRES2019-0187 Type: FIRE SPRINKLER Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 2/12/2020 AHI Parcel No: 770370005 Site Address: 53630 DEL GATO DR LA QUINTA,CA 92253 Approved: 3/10/2020 KHET Subdivision: TR 28867 Block: Lot: 104 Issued: 3/11/2020 JLIM Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 11/3/2020 KHET Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Wednesday, February 08, 2023 12:45:40 PM 1 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0030 E-MAIL KOHL HETRICK 10/20/2020 10/20/2020 Now that I am back in the office, I wanted to touch back with you and discuss the options. Option 1: (As originally conditioned at Rough Inspection) Submit Revisions with Calculations showing the ¾” WM and 125’ of 1” UG supply is sufficient. Option 2: Bucket Test of the 2 most – remote/demanding design heads to confirm adequate flow. *Test procedure attached. Option 3: Upgrade the water meter to 1” as per original approved Calcs. *Consider upgrading the UG piping size from the Meter to BOR. Please let me know what you would like to do. NOTE KAYLI ALFORD 10/15/2020 10/15/2020 CONTRACTOR REQUESTED INSPECTION. INFORMED THEM THE PERMIT IS EXPIRED AND EXTENSION LETTER & FEE WILL BE DUE PRIOR TO EXTENDING. OK TO EXTEND PER KOHL. NOTE KAYLI ALFORD 10/19/2020 10/19/2020 PERMIT EXTENDED TO 10/20/20 SO CONTRACTOR CAN PAY EXTENSION FEE ON ETRAKIT. PER KOHL, REQUIREMENT FOR REVISION SUBMITTAL WITH REVISED CALCS WILL BE WAIVED. RECEIVED PERMIT EXTENSION REQUEST LETTER & EXTENSION FEE PAYMENT. EXTENDED PERMIT BY 6 MOS TO 4/19/21. PLAN CHECK PICKED UP JACK LIMA 3/3/2020 3/3/2020 1ST PLAN CORRECTIONS PICKED UP BY MARK TRELAK. PUBLIC COUNTER VISIT JACK LIMA 3/11/2020 3/11/2020 PERMIT ISSUED TO MARK TRELAK. RESUBMITTAL JACK LIMA 3/6/2020 3/6/2020 2ND PLAN RESUBMITTAL MADE BY MARK TRELAK. CONDITIONS Printed: Wednesday, February 08, 2023 12:45:40 PM 2 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0030 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT DESERT FIRE EXTINGUISHER CO INC PO BOX 1607 PALM SPRINGS CA 92263 (306)221-9634 MARK@DESERT- FIRE.COM CONTRACTOR DESERT FIRE EXTINGUISHER CO INC PO BOX 1607 PALM SPRINGS CA 92263 (306)221-9634 MARK@DESERT- FIRE.COM OWNER DONALD J & JANET C NEUFELD 53630 DEL GATO LA QUINTA CA 92253 (306)221-9634 DON@JHBUILDERS.CO M FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 11/2/20 WEB6649 036239 CREDIT DESERT FIRE EXTINGUISHER CO INC ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $242.00 $242.00 2/12/20 R59542 445 CHECK DESERT FIRE EXTINGUISHER CO IN AHI FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $241.00 $241.00 2/12/20 R59542 445 CHECK DESERT FIRE EXTINGUISHER CO IN AHI FIRE STAFF - PER HOUR 101-0000-42420 0.25 $40.25 $40.25 10/19/20 WEB6538 077425 CREDIT DESERT FIRE EXTINGUISHER CO INC ECON Total Paid for FIRE FEES: $684.25 $684.25 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 2/12/20 R59542 445 CHECK DESERT FIRE EXTINGUISHER CO IN AHI Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 2/12/20 R59542 445 CHECK DESERT FIRE EXTINGUISHER CO IN AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$699.25 $699.25 Printed: Wednesday, February 08, 2023 12:45:40 PM 3 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0030 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 3/16/2020 3/16/2020 APPROVED See Notes (DISREGARD: Revisions and calcs required prior to final. ) Confirm at final: 1) Add 1 head in kitchen ceiling pocket. 2) Add 1 head in bedroom 2 closet. 3) Add 1 head in bedroom 3 bath. 4) Add 1 head under bedroom 4 entry soffit. OVERHEAD HYRO KHET 3/16/2020 3/16/2020 APPROVED FIRE FINAL**KHET 10/20/2020 10/20/2020 DISAPPROVE D Observed 3/4" WM and approximately 125' of UG to new Riser Location. This is the reason for the original requirement to submit Revised Plans with Updated Hydraulic Calcs. Contractor did not have approved plans on site. PDF plans and calcs were resourced via email and updated with redline field notes based on observed conditions. (3) options: 1) Provide Revisions with Calcs that show the current WM and UG supply is sufficient. 2) Bucket Test of 2 remote/demanding heads. 3) Upgrade the underground and water meter. FIRE FINAL**KHET 11/3/2020 11/3/2020 APPROVED REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 2/12/2020 2/13/2020 2/12/2020 COMPLETE PARENT PROJECTS Printed: Wednesday, February 08, 2023 12:45:40 PM 4 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0030 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/5/2021 JOSE DELGADO Fire Review Application Revision.pdf Fire Review Application Revision.pdf 0 DOC 11/5/2021 JOSE DELGADO Fire Review Application.pdf Fire Review Application.pdf 0 DOC 11/5/2021 JOSE DELGADO Approved Hydraulic Design Information Sheet.pdf Approved Hydraulic Design Information Sheet.pdf 0 DOC 11/5/2021 JOSE DELGADO Approved FSS2020- 00030.pdf Approved FSS2020- 00030.pdf 0 DOC 10/19/2020 KAYLI ALFORD Extension Request Letter.pdf Extension Request Letter.pdf 0 DOC 3/3/2020 KOHL HETRICK FSS2020-0030 - NEUFIELD RESIDENCE - 1ST PC CORR.docx FSS2020-0030 - NEUFIELD RESIDENCE - 1ST PC CORR.docx 0 DOC 3/10/2020 KOHL HETRICK FSS2020-0030 - NEUFIELD HOUSE - RESUBM 1 - APPR.pdf FSS2020-0030 - NEUFIELD HOUSE - RESUBM 1 - APPR.pdf 0 DOC 10/20/2020 KOHL HETRICK NEUFIELD HOUSE HYD CALC.pdf NEUFIELD HOUSE HYD CALC.pdf 1 DOC 10/20/2020 KOHL HETRICK NEUFIELD HOUSE HYD GRPAH.pdf NEUFIELD HOUSE HYD GRPAH.pdf 1 DOC 10/20/2020 KOHL HETRICK NEUFIELD HOUSE.pdf NEUFIELD HOUSE.pdf 1 BOND INFORMATION 1ST FIRE (2 WK)KOHL HETRICK 2/12/2020 2/26/2020 3/3/2020 REVISIONS REQUIRED SEE ATTACHMENTS 2ND FIRE (1 WK)KOHL HETRICK 3/6/2020 3/13/2020 3/10/2020 APPROVED 1ST FIRE (1 DAY)KOHL HETRICK 10/28/2020 10/28/2020 10/28/2020 APPROVED REVISED PLANS/CALCS Printed: Wednesday, February 08, 2023 12:45:40 PM 5 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0030 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/28/2020 KOHL HETRICK FSS2020-0030 - REVISED PLANS AND CALCS - APPROVED.pdf FSS2020-0030 - REVISED PLANS AND CALCS - APPROVED.pdf 1 Printed: Wednesday, February 08, 2023 12:45:40 PM 6 of 6 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0030 3/4" CITY WATER METERCONNECTION TO CITYNO CLOSETS UNDER 24 SQ FT SHALL BE SPRINKLEREDNO BATHROOMS UNDER 55 SQ FT SHALL BE SPRINKLERED5 GPM LOSS FORDOMESTIC USEDEL GATTOI s land 10'-0" Soffit10'-0" Soffit10'-0" Soffit10'-0" Soffit10'-0" Soffit8'-6" Soffit11'-8" Soffit9'-8" Soffit9'-8" Soffit9'-8" Soffit8'-0" Soffit9'-0" Soffit10'-0" Soffit10'-0" Soffit8'-6" Soffit10'-0" Ceiling Ht.10'-0" Ceiling Ht.12'-0" Ceiling Ht.9'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.11'-0" Ceiling Ht.10'-0" Ceiling Ht.11'-0" Ceiling Ht.12'-0" Ceiling Ht.13'-0" Ceiling Ht.12'-0" Ceiling Ht.12'-0" Ceiling Ht.14'-6" Ceiling Ht.12'-0" Soffit13'-0" Ceiling Ht.11'-6" Soffit9'-7" Soffit8'-6" Soffit8'-6" Soffit10'-0" Ceiling Ht.11'-0" Ceiling Ht.13'-0" Ceiling Ht.13'-10" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.9'-0" Ceiling Ht.13'-6" Soffit14'-6" Ceiling Ht.9'-7" Soffit10'-0" Soffit10'-0" Soffit10'-0" Soffit10'-0" Soffit10'-0" Ceiling Ht.10'-0" Ceiling Ht.9'-0" Ceiling Ht.12X812X812X812X812X810X610X610X610X610'-0" Ceiling Ht.10'-0" Ceiling Ht.13'-0" Ceiling Ht.NEW HOUSE PIPING PLAN.SCALE 1/8" = 1'-0"NOTE:EACH POCKET DOES NOT EXCED 100 CU FTTHE ENTIRE FLOOR AREA IS COVERED BY THE LOWER CEILING SPRINKLERSNOTE:EACH POCKET DOES NOT EXCED 100 SQ FTTHE ENTIRE FLOOR AREA IS COVERED BY THE LOWER CEILING SPRINKLERSNOTE:EACH POCKET DOES NOT EXCED 100 CU FTTHE ENTIRE FLOOR AREA IS COVERED BY THE LOWER CEILING SPRINKLERS1 0 ' - 0 " C E I L ING H E IGH T 1 0 ' - 0 " C E I L ING H E IGH T1" PVC PIPE 125'-0"JOB NUMBER: APPROVAL: LQ FD SCALE:AS NOTED SHEET:1 OF 1 WATER SOURCE: CVWD CALCULATED WETSYSTEM TYPE HAZARD TOTAL DEMAND TOTAL SYSTEM AREA OF SYSTEM DESIGN DATA HYDRAULIC TOTAL AMOUNT OF HEADS ON THIS SHEET QUANTITYFINISHKTEMP.NPTTYPE ESC.SYMBOL MAKE, MODEL & S.I.N. FIRE SPRINKLERINSTALLATIONSDESIGN DRAWN BY: AARON J DATE: 10/28/2020 DESERT 558 INDUSTRIAL PLACE PALM SPRINGS, CA 92264 760 322-0995 FIRE EXTINGUISHER FIRE SPRINKLER LEGEND SSP 1/2 4.9 200°TYCO TYFRB PENDENT TY2234 TYCO LF II CONCEALED PENDANTS TY 3596 SSP 1/2 4.9 155°WHITE WHITE WHITEWHITE CLASSIFICATION:RESIDENTAIL 13D DESIGN DATA:16X16 APPLICATION: REQUIREMENTS: AT SOURCE: 26.0 GPM @ 25.0 PSI AT BASE OF RISER SQFT DOMESTIC .05 GPM 256 SQ FT/HD 92 STATIC PRESS.RESIDUAL PRESS. 85 PSI@ 1500 GPMSUPPLY: CONTRACT WITHAPPROVALSPHONEJOB:NEUFIELD HOUSE LA QUINTA, CA 55 64 9 C-16# 563921 53630 DEL GATTO DR 1-1/2" OFFSET EDGE FOR ABRASION ELIMINATION REQUIRED FASTENER FURNISHED WITH THE HANGER,NEEDS NO PREDRILLINGSPACE HANGERS PER CHART BELOWAND SUPERIOR STRENGTHFEATURES:OFFSET PIPE/CPVC HANGERAFCON NO. 514 MATERIAL: CARBON STEELFINISH: MIL. GALVANIZEDSIZE: 3/4" THRU 2" PIPELISTING: UL IN US AND CANADAINSTALLATION: INSTALL ON THE SIDEOF WOOD BEAMS AS DESCRIBED:INSTALLED PER NFPA 13, 13R, AND 13DFUNCTION: HANGER FOR USE OF CPVC PIPINGFURNISHED WITH PRODUCT. INSTALL FASTENERS, AS FOLLOWS:IN WOOD - USE LISTED HEX HEAD SCREW AROUND PIPE ALLOWING PIP TO SLIDE FREELYSNAP OVER PIPE THEN SQUEEZE STRAP BACK "A""B"RISER DETAIL1"TO SPRINKLER SYSTEMFROM UGBORNO SCALERISER TO BE ACCESSIBLEIF ACCESS DOOR IS INSTALLEDLABEL DOOR "FIRE SPRINKLER RISER"ACCESS DOOR BY OTHERS.1" CPVC 90 ELLW 1" CITY WATER METERCONNECTION TO CITYNO CLOSETS UNDER 24 SQ FT SHALL BE SPRINKLEREDNO BATHROOMS UNDER 55 SQ FT SHALL BE SPRINKLERED5 GPM LOSS FORDOMESTIC USEDEL GATTOI s land 10'-0" Soffit10'-0" Soffit10'-0" Soffit10'-0" Soffit10'-0" Soffit8'-6" Soffit11'-8" Soffit9'-8" Soffit9'-8" Soffit9'-8" Soffit8'-0" Soffit9'-0" Soffit10'-0" Soffit10'-0" Soffit8'-6" Soffit10'-0" Ceiling Ht.10'-0" Ceiling Ht.12'-0" Ceiling Ht.9'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.11'-0" Ceiling Ht.10'-0" Ceiling Ht.11'-0" Ceiling Ht.12'-0" Ceiling Ht.13'-0" Ceiling Ht.12'-0" Ceiling Ht.12'-0" Ceiling Ht.14'-6" Ceiling Ht.12'-0" Soffit13'-0" Ceiling Ht.11'-6" Soffit9'-7" Soffit8'-6" Soffit8'-6" Soffit10'-0" Ceiling Ht.11'-0" Ceiling Ht.13'-0" Ceiling Ht.13'-10" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.10'-0" Ceiling Ht.9'-0" Ceiling Ht.13'-6" Soffit14'-6" Ceiling Ht.9'-7" Soffit10'-0" Soffit10'-0" Soffit10'-0" Soffit10'-0" Soffit10'-0" Ceiling Ht.10'-0" Ceiling Ht.9'-0" Ceiling Ht.12X812X812X812X812X810X610X610X610X610'-0" Ceiling Ht.10'-0" Ceiling Ht.13'-0" Ceiling Ht.NEW HOUSE PIPING PLAN.SCALE 1/8" = 1'-0"NOTE:EACH POCKET DOES NOT EXCED 100 CU FTTHE ENTIRE FLOOR AREA IS COVERED BY THE LOWER CEILING SPRINKLERSNOTE:EACH POCKET DOES NOT EXCED 100 SQ FTTHE ENTIRE FLOOR AREA IS COVERED BY THE LOWER CEILING SPRINKLERSNOTE:EACH POCKET DOES NOT EXCED 100 CU FTTHE ENTIRE FLOOR AREA IS COVERED BY THE LOWER CEILING SPRINKLERS1 0 ' - 0 " C E I L ING H E IGH T 1 0 ' - 0 " C E I L ING H E IGH T1" PVC PIPE 50'-0"JOB NUMBER: APPROVAL: LQ FD SCALE:AS NOTED SHEET:1 OF 1 WATER SOURCE: CVWD CALCULATED WETSYSTEM TYPE HAZARD TOTAL DEMAND TOTAL SYSTEM AREA OF SYSTEM DESIGN DATA HYDRAULIC TOTAL AMOUNT OF HEADS ON THIS SHEET QUANTITYFINISHKTEMP.NPTTYPE ESC.SYMBOL MAKE, MODEL & S.I.N. FIRE SPRINKLERINSTALLATIONSDESIGN DRAWN BY: AARON J DATE: 2/10/2019 DESERT 558 INDUSTRIAL PLACE PALM SPRINGS, CA 92264 760 322-0995 FIRE EXTINGUISHER FIRE SPRINKLER LEGEND SSP 1/2 4.9 200°TYCO TYFRB PENDENT TY2234 TYCO LF II CONCEALED PENDANTS TY 3596 SSP 1/2 4.9 155°WHITE WHITE WHITEWHITE CLASSIFICATION:RESIDENTAIL 13D DESIGN DATA:16X16 APPLICATION: REQUIREMENTS: AT SOURCE: 26.0 GPM @ 25.0 PSI AT BASE OF RISER SQFT DOMESTIC .05 GPM 256 SQ FT/HD 92 STATIC PRESS.RESIDUAL PRESS. 85 PSI@ 1500 GPMSUPPLY: CONTRACT WITHAPPROVALSPHONEJOB:NEUFIELD HOUSE LA QUINTA, CA 55 64 9 C-16# 563921 53630 DELGATO DRIVE 1-1/2" OFFSET EDGE FOR ABRASION ELIMINATION REQUIRED FASTENER FURNISHED WITH THE HANGER,NEEDS NO PREDRILLINGSPACE HANGERS PER CHART BELOWAND SUPERIOR STRENGTHFEATURES:OFFSET PIPE/CPVC HANGERAFCON NO. 514 MATERIAL: CARBON STEELFINISH: MIL. GALVANIZEDSIZE: 3/4" THRU 2" PIPELISTING: UL IN US AND CANADAINSTALLATION: INSTALL ON THE SIDEOF WOOD BEAMS AS DESCRIBED:INSTALLED PER NFPA 13, 13R, AND 13DFUNCTION: HANGER FOR USE OF CPVC PIPINGFURNISHED WITH PRODUCT. INSTALL FASTENERS, AS FOLLOWS:IN WOOD - USE LISTED HEX HEAD SCREW AROUND PIPE ALLOWING PIP TO SLIDE FREELYSNAP OVER PIPE THEN SQUEEZE STRAP BACK "A""B"RISER DETAIL1"TO SPRINKLER SYSTEMFROM UGBORNO SCALERISER TO BE ACCESSIBLEIF ACCESS DOOR IS INSTALLEDLABEL DOOR "FIRE SPRINKLER RISER"ACCESS DOOR BY OTHERS.1" CPVC 90 ELLW