FSS2020-0042ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET CONTRACTOR J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET OWNER RYAN SCOTT 1977 GLENCOE WAY HOLLYWOOD CA 0 CONDITIONS Description: ROSINI / BRES2018-0361 / FIRE SPRINKLERS Type: FIRE SPRINKLER Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 3/3/2020 AHI Parcel No: 774275012 Site Address: 77530 CALLE POTRERO LA QUINTA,CA 92253 Approved: 3/23/2020 KHET Subdivision: SANTA CARMELITA AT VALE LA QUINTA UNIT 28 Block: 307 Lot: 13 Issued: 3/23/2020 KHET Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 6/24/2020 KHET Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: FINANCIAL INFORMATION Printed: Thursday, January 19, 2023 10:34:45 AM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0042 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 3/30/2020 3/30/2020 APPROVED OVERHEAD HYRO KHET 3/30/2020 3/30/2020 APPROVED FIRE FINAL**KHET 6/24/2020 6/24/2020 APPROVED REMOTE VIDEO INSPECTION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 3/3/20 R60187 1847 CHECK JC FIRE AHI FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 3/3/20 R60187 1847 CHECK JC FIRE AHI Total Paid for FIRE FEES: $403.00 $403.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 3/3/20 R60187 1847 CHECK JC FIRE AHI Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 3/3/20 R60187 1847 CHECK JC FIRE AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$418.00 $418.00 Printed: Thursday, January 19, 2023 10:34:45 AM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0042 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 3/23/2020 ARMANDO MAGALLON 1ST SUBMITTAL - CUTSHEETS 4193_001.pdf 0 DOC 3/23/2020 ARMANDO MAGALLON APPLICATION 4194_001.pdf 0 DOC 3/20/2020 EtrakitContractor FIRE FLOW LETTER Residential Connection Charge Estimate - 77530 Portrero.pdf 1 DOC 3/23/2020 KOHL HETRICK FSS2020-0042 - PLANS - APPROVED.pdf FSS2020-0042 - PLANS - APPROVED.pdf 1 DOC 3/23/2020 KOHL HETRICK FSS2020-0042 - INSP PLANS - APPROVED.pdf FSS2020-0042 - INSP PLANS - APPROVED.pdf 0 DOC 3/23/2020 KOHL HETRICK FSS2020-0042 - 1 HD CALC - APPROVED.pdf FSS2020-0042 - 1 HD CALC - APPROVED.pdf 1 DOC 3/23/2020 KOHL HETRICK FSS2020-0042 - 2 HD CALC - APPROVED.pdf FSS2020-0042 - 2 HD CALC - APPROVED.pdf 1 DOC 3/23/2020 KOHL HETRICK FSS2020-0042 - ROSINI - COA AND JOB CARD.pdf FSS2020-0042 - ROSINI - COA AND JOB CARD.pdf 1 DOC 3/30/2020 KOHL HETRICK FSS2020-0042 - AS BUILT PLANS - APPROVED.pdf FSS2020-0042 - AS BUILT PLANS - APPROVED.pdf 1 BOND INFORMATION 1ST PERMIT TECH (1 DAY) PERMIT TECH BUCKET 3/3/2020 3/4/2020 3/4/2020 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 3/3/2020 3/17/2020 3/23/2020 APPROVED Printed: Thursday, January 19, 2023 10:34:45 AM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0042 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs NINO ROSINI Scottsdale, AZ 85260 Page 1 General Project Data Report General Data Project Title: NINO ROSINI Project File Name: JCF - NINO ROSINI..fiw Designed By: Vallie Schilt Date: March 02, 2020 Code Reference:Approving Agency: "F" FITTING = "T" RUN Client Name:Phone: Address:City, State Zip Code: Company Name:Representative: Company Address:City And State: Phone: Building Name: BDRM 1 HEAD @ 20 X 20 Building Owner: Contact at Building:Phone at Building: Address Of Building: 77530 CALLE PORTRERO City, State Zip Code: LA QUINTA, AZ Project Data Description Of Hazard: Residential Sprinkler System Type: Wet Design Area Of Water Application: 400 ft² Maximum Area Per Sprinkler: 400 ft² Default Sprinkler K-Factor: 0.00 K Default Pipe Material: BLAZEMASTER CPVC Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 0.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: VIKING Model:494 Size:7/16 Temperature Rating: 165 F Water Supply Test Data Source Of Information: TEST RESIDUAL = STATIC - 10% Test Hydrant ID:Date Of Test: Hydrant Elevation: 0 ft Static Pressure: 56.90 psi Test Flow Rate: 30.00 gpm Test Residual Pressure: 51.20 psi Calculated System Flow Rate: 25.02 gpm Calculated Inflow Residual Pressure: 37.36 psi Available Residual Pressure At System Flow:52.82 psi Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 16.70 psi Minimum Desired Flow Density: 0.05 gpm/ft² Maximum Water Velocity: 0.00 ft/s Maximum Frictional Loss / 100 feet: 20.00 psi Number Of Active Nodes: 9 Number Of Active Pipes: 8 Number Of Inactive Pipes: 42 Number Of Active Sprinklers: 1 Number Of Inactive Sprinklers: 0 Monday, March 02, 2020, 12:07 PM APPROVED Riverside County Fire Department La Quinta Office of the Fire Marshal By: countyfire 03/23/2020 11:58:26 AM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or anyLocal Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. Kohl Hetrick Digitally signed by Kohl Hetrick DN: C=US, E=kohl.hetrick@fire.ca.gov, O=Riverside County Fire Department, OU=La Quinta Office of the Fire Marshal, CN=Kohl Hetrick Location: 78495 Calle Tampico, La Quinta, 92253Reason: I have reviewed this document Contact Info: 760-777-7074 Date: 2019.07.23 08:23:01-07'00' FSS2020-0042 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs NINO ROSINI Scottsdale, AZ 85260 Page 2 Fire Sprinkler Output Data Overall Pipe Output Data Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 30.0010.500.0018.641.000.000.0000035.000.000 50.0010.500.0018.641.1010.00 4F4.000.000 BLAZEMASTER CPVC 150 0.00 0 39.00 0.000 44.9010.0020.0216.701.0020.020.0682118.602.156 50.0010.500.0018.641.10120.02FET13.00-0.217 BLAZEMASTER CPVC 150 6.75 0 31.60 1.939 50.0010.500.0018.641.000.000.0682242.004.434 75 0.00 10.50 0.00 23.07 1.101 20.02 4F2ET 23.00 0.000 BLAZEMASTER CPVC 150 6.75 0 65.00 4.434 75 0.00 10.50 0.00 23.07 1.00 0.00 0.06822 9.50 0.853 100 0.00 5.00 0.00 26.31 1.101 20.02 3F 3.00 2.382 BLAZEMASTER CPVC 150 6.75 0 12.50 3.234 100 FS 5.00 26.31 20.00 110 3.00 psi 5.00 29.31 110 0.00 5.00 0.00 29.31 1.00 0.00 0.09665 5.50 1.691 120 0.00 0.00 5.00 33.16 1.025 20.02 ETC 12.00 2.165 TYPE L COPPER TUBE 150 7.79 0 17.50 3.856 120 0.00 0.00 5.00 33.16 1.00 5.00 0.14598 3.00 1.752 130 0.00 -2.00 0.00 35.78 1.025 25.02 3E 9.00 0.866 TYPE L COPPER TUBE 150 9.73 0 12.00 2.618 130 0.00 -2.00 0.00 35.78 1.25 0.00 0.03683 35.00 1.584 140 0.00 -2.00 0.00 37.36 1.360 25.02 2E 8.00 0.000 SCHEDULE 40 PVC 150 5.53 0 43.00 1.584 Fitting Legend: F = 45 Degree Elbow, E = 90 Degree Elbow, L = Long Turn Elbow, T = Tee or Cross, B = Butterfly Valve, G = Gate Valve, C = Check Valve Monday, March 02, 2020, 12:07 PM Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs NINO ROSINI Scottsdale, AZ 85260 Page 3 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number:4 HMD Actual Residual Pressure:16.70 psi HMD Actual GPM:20.02 gpm Sprinkler Summary Sprinkler System Type:Wet Specified Area Of Application:400.00 ft² Minimum Desired Density:0.050 gpm/ft² Application Average Density:0.050 gpm/ft² Application Average Area Per Sprinkler: 400.00 ft² Sprinkler Flow:20.02 gpm Average Sprinkler Flow:20.02 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity ( In Pipe 120 - 130 ) 9.73 ft/sec Maximum Velocity Pressure ( In Pipe 120 - 130 ) 0.64 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0068 psi Actual Average Nodal Pressure Imbalance: 0.0031 psi Actual Maximum Nodal Flow Imbalance: -0.0236 gpm Actual Average Nodal Flow Imbalance: 0.0054 gpm Overall Network Summary Number Of Unique Pipe Sections:8 Number Of Flowing Sprinklers:1 Pipe System Water Volume:2.55 gal Sprinkler Flow:20.02 gpm Non-Sprinkler Flow:5.00 gpm Minimum Required Residual Pressure At System Inflow Node:37.36 psi Demand Flow At System Inflow Node: 25.02 gpm Monday, March 02, 2020, 12:07 PM Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs NINO ROSINI Scottsdale, AZ 85260 Page 4 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph Pressure psiFlowrate(x100) gpm 57 51 4 0 10 20 30 40 50 60 70 80 90 100 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Supply Curve Data Static Pressure: 56.9 psi Test Residual Pressure: 51.2 psi Test Flow Rate: 30 gpm Demand Curve Data Calculated Residual Pressure: 37.36 psi Calculated Flow Rate: 25.02 gpm Excess Available Residual Pressure At Calculated Flow: 15.46 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 0.00 psi Monday, March 02, 2020, 12:07 PM Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs NINO ROSINI Scottsdale, AZ 85260 Page 1 General Project Data Report General Data Project Title: NINO ROSINI Project File Name: JCF - NINO ROSINI..fiw Designed By: Vallie Schilt Date: March 02, 2020 Code Reference:Approving Agency: "F" FITTING = "T" RUN Client Name:Phone: Address:City, State Zip Code: Company Name:Representative: Company Address:City And State: Phone: Building Name: GARAGE 2 HEAD @ 14 X 14 Building Owner: Contact at Building:Phone at Building: Address Of Building: 77530 CALLE PORTRERO City, State Zip Code: LA QUINTA, AZ Project Data Description Of Hazard: Residential Sprinkler System Type: Wet Design Area Of Water Application: 392 ft² Maximum Area Per Sprinkler: 196 ft² Default Sprinkler K-Factor: 0.00 K Default Pipe Material: BLAZEMASTER CPVC Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 0.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: VIKING Model:470 Size:7/16 Temperature Rating: 175 F Water Supply Test Data Source Of Information: TEST RESIDUAL = STATIC - 10% Test Hydrant ID:Date Of Test: Hydrant Elevation: 0 ft Static Pressure: 56.90 psi Test Flow Rate: 30.00 gpm Test Residual Pressure: 51.20 psi Calculated System Flow Rate: 25.08 gpm Calculated Inflow Residual Pressure: 32.79 psi Available Residual Pressure At System Flow:52.81 psi Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 11.12 psi Minimum Desired Flow Density: 0.05 gpm/ft² Maximum Water Velocity: 0.00 ft/s Maximum Frictional Loss / 100 feet: 20.00 psi Number Of Active Nodes: 10 Number Of Active Pipes: 9 Number Of Inactive Pipes: 41 Number Of Active Sprinklers: 2 Number Of Inactive Sprinklers: 0 Monday, March 02, 2020, 12:04 PM APPROVED Riverside County Fire Department La Quinta Office of the Fire Marshal By: countyfire 03/23/2020 11:58:20 AM The approval of plans and specifications does notpermit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. Kohl Hetrick Digitally signed by Kohl Hetrick DN: C=US, E=kohl.hetrick@fire.ca.gov, O=Riverside County Fire Department, OU=La Quinta Office of the Fire Marshal, CN=Kohl Hetrick Location: 78495 Calle Tampico, La Quinta, 92253 Reason: I have reviewed this document Contact Info: 760-777-7074 Date: 2019.07.23 08:23:01-07'00' FSS2020-0042 Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs NINO ROSINI Scottsdale, AZ 85260 Page 2 Fire Sprinkler Output Data Overall Pipe Output Data Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 13.0010.0010.0011.121.0010.000.0188910.600.427 30.0010.500.0011.331.10110.00 ET12.00-0.217 BLAZEMASTER CPVC 150 3.37 0 22.60 0.211 23.0010.0010.0811.291.0010.080.019161.600.261 30.0010.500.0011.331.10110.08 ET12.00-0.217 BLAZEMASTER CPVC 150 3.40 0 13.60 0.044 30.0010.500.0011.331.000.000.0685935.002.675 50.0010.500.0014.011.10120.08 4F4.000.000 BLAZEMASTER CPVC 150 6.77 0 39.00 2.675 50.0010.500.0014.011.000.000.0685942.004.458 75 0.00 10.50 0.00 18.46 1.101 20.08 4F2ET 23.00 0.000 BLAZEMASTER CPVC 150 6.77 0 65.00 4.458 75 0.00 10.50 0.00 18.46 1.00 0.00 0.06859 9.50 0.857 100 0.00 5.00 0.00 21.70 1.101 20.08 3F 3.00 2.382 BLAZEMASTER CPVC 150 6.77 0 12.50 3.239 100 FS 5.00 21.70 20.06 110 3.00 psi 5.00 24.71 110 0.00 5.00 0.00 24.71 1.00 0.00 0.09717 5.50 1.701 120 0.00 0.00 5.00 28.57 1.025 20.08 ETC 12.00 2.165 TYPE L COPPER TUBE 150 7.81 0 17.50 3.866 120 0.00 0.00 5.00 28.57 1.00 5.00 0.14661 3.00 1.759 130 0.00 -2.00 0.00 31.20 1.025 25.08 3E 9.00 0.866 TYPE L COPPER TUBE 150 9.75 0 12.00 2.625 130 0.00 -2.00 0.00 31.20 1.25 0.00 0.03699 35.00 1.591 140 0.00 -2.00 0.00 32.79 1.360 25.08 2E 8.00 0.000 SCHEDULE 40 PVC 150 5.54 0 43.00 1.591 Fitting Legend: F = 45 Degree Elbow, E = 90 Degree Elbow, L = Long Turn Elbow, T = Tee or Cross, B = Butterfly Valve, G = Gate Valve, C = Check Valve Monday, March 02, 2020, 12:04 PM Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs NINO ROSINI Scottsdale, AZ 85260 Page 3 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number:1 HMD Actual Residual Pressure:11.12 psi HMD Actual GPM:10.00 gpm Sprinkler Summary Sprinkler System Type:Wet Specified Area Of Application:392.00 ft² Minimum Desired Density:0.050 gpm/ft² Application Average Density:0.051 gpm/ft² Application Average Area Per Sprinkler: 196.00 ft² Sprinkler Flow:20.08 gpm Average Sprinkler Flow:10.04 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity ( In Pipe 120 - 130 ) 9.75 ft/sec Maximum Velocity Pressure ( In Pipe 120 - 130 ) 0.64 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0065 psi Actual Average Nodal Pressure Imbalance: 0.0026 psi Actual Maximum Nodal Flow Imbalance: 0.0233 gpm Actual Average Nodal Flow Imbalance: 0.0047 gpm Overall Network Summary Number Of Unique Pipe Sections:9 Number Of Flowing Sprinklers:2 Pipe System Water Volume:2.80 gal Sprinkler Flow:20.08 gpm Non-Sprinkler Flow:5.00 gpm Minimum Required Residual Pressure At System Inflow Node:32.79 psi Demand Flow At System Inflow Node: 25.08 gpm Monday, March 02, 2020, 12:04 PM Fire - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. Living Water Designs NINO ROSINI Scottsdale, AZ 85260 Page 4 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph Pressure psiFlowrate(x100) gpm 57 51 4 0 10 20 30 40 50 60 70 80 90 100 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Supply Curve Data Static Pressure: 56.9 psi Test Residual Pressure: 51.2 psi Test Flow Rate: 30 gpm Demand Curve Data Calculated Residual Pressure: 32.79 psi Calculated Flow Rate: 25.08 gpm Excess Available Residual Pressure At Calculated Flow: 20.02 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 0.00 psi Monday, March 02, 2020, 12:04 PM OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org March 23, 2020 JC Fire Protection 81705 De Oro Ave Indio, CA 92201 Re: Residential Fire Sprinkler Plan Review – ROSINI RESIDENCE FSS2020-0042 / 77530 CALLE POTRERO, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 77530 CALLE POTRERO PERMIT#: FSS2020-0042 DATE ISSUED: 3/23/2020 DESCRIPTION: RES FIRE SPRINKLER CONTRACTOR: JC FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible dur ing the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.