FSS2020-0054ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 4/1/2020 4/1/2020 EMAILED APPLICANT TO OBTAIN A CITY BL AND AND CREATED A CONTRACTOR ACCOUNT FOR ETRAKIT. E-MAIL AARON HICKSON 4/15/2020 4/15/2020 RCEIVED BL APPLICATION NOTE AARON HICKSON 4/20/2020 4/20/2020 CONTRACTOR PAID FEE FOR CITY BL TRANSFERED FEE TO BL NOTE KAYLI ALFORD 12/2/2020 12/2/2020 CONTRACTOR REQUESTED INSPECTION BUT PERMIT IS EXPIRED AS OF 11/1/20. CONTRACTOR WAS INFORMED OF EXTENSION FEE AND THAT AN EXTENSION REQUEST LETTER WAS REQUIRED. PERMIT WILL BE EXTENDED TO 12/3/20 TO ALLOW CONTRACTOR TO PAY FEE VIA ETRAKIT. OK TO EXTEND PER KOHL EXTENSION REQUEST LETTER & EXTENSION FEE PAYMENT RECEIVED. PERMIT EXTENDED BY 6 MOS TO 6/3/21 Description: ABSOLUTE PARTNERS / BRES2018-0188 / FIRE SPRINKLERS Type: FIRE SPRINKLER (WEB)Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 3/31/2020 EPRS Parcel No: 766060027 Site Address: 58585 QUARRY RANCH RD LA QUINTA,CA 92253 Approved: 4/15/2020 KHET Subdivision: TR 30651 Block: Lot: 6 Issued: 4/20/2020 Online Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 12/3/2020 KHET Valuation: $11,500.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Design and Install of a NFPA 13D Automatic Fire Sprinkler System Printed: Friday, February 17, 2023 9:48:58 AM 1 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0054 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT Blake Chapman 179 Torremolinos Dr Rancho Mirage CA 92270 (760)835-7453 bchapman@worldfirep rotection.com BILL TO World Fire Protection, Inc 41-905 Boardwalk Suite B Palm Desert CA 92211 (760)835-7453 bchapman@worldfirep rotection.com CONTRACTOR WORLD FIRE PROTECTION INC PO BOX 2596 RANCHO MIRAGE CA 92270 (760)835-7453 bchapman@worldfirep rotection.com OWNER ABSOLUTE PARTNERS, LLC.58585 QUARRY RANCH RD Palm Desert CA 92211 (760)835-7453 robert@absolute- partners.com CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST AARON HICKSON 4/1/2020 4/21/2020 4/21/2020 COMPLETE CITY BUSINESS LICENSE REQUIRED BL FEE PAID ON THIS PERMIT AND TRANSFERRED TO FSS2020-0054 NOTE KOHL HETRICK 4/27/2020 4/27/2020 Remote Video Inspection attempted on 4/27/2020 was unsuccessful due to poor cellular signal in The Quarry development area. Rescheduled for 4/28/2020 at 1300. CONDITIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE FAILED OR ADDITIONAL RE- INSPECTION 101-0000-42421 0 $161.00 $161.00 4/29/20 WEB5012 CREDIT WORLD FIRE PROTECTION INC ECON FIRE PLAN REVISION SUBMITTALS 101-0000-42420 0 $161.00 $161.00 4/29/20 WEB5012 CREDIT WORLD FIRE PROTECTION INC ECON FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 3/31/20 WEB4791 032556 CREDIT Blake Chapman EPRS Printed: Friday, February 17, 2023 9:48:58 AM 2 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0054 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 4/28/2020 4/28/2020 DISAPPROVE D SEE ATTACHMENTS OVERHEAD HYRO KHET 4/28/2020 4/28/2020 DISAPPROVE D SEE ATTACHMENTS OVERHEAD ROUGH PIPING KHET 5/5/2020 5/5/2020 APPROVED OVERHEAD HYRO KHET 5/5/2020 5/5/2020 APPROVED FIRE FINAL**KHET 12/3/2020 12/3/2020 APPROVED REMOTE VIDEO INSPECTION REVIEWS PARENT PROJECTS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $242.00 $242.00 3/31/20 WEB4791 032556 CREDIT Blake Chapman EPRS FIRE STAFF - PER HOUR 101-0000-42420 0.25 $40.25 $40.25 12/2/20 WEB6892 036452 CREDIT WORLD FIRE PROTECTION INC ECON Total Paid for FIRE FEES: $765.25 $765.25 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 3/31/20 WEB4791 032556 CREDIT Blake Chapman EPRS Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 3/31/20 WEB4791 032556 CREDIT Blake Chapman EPRS Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$780.25 $780.25 Printed: Friday, February 17, 2023 9:48:58 AM 3 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0054 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/29/2020 EtrakitContractor Revised Calcs Document.pdfCalc-1 Quarry.pdf 1 DOC 4/29/2020 EtrakitContractor Water Flow Doc - Mar 25 2020 - 2-47 PM_1.pdf 1 DOC 4/29/2020 EtrakitContractor Revised Plans Quarry Ranch.pdfDetail.pdf 1 DOC 4/29/2020 EtrakitContractor Revised Plans Quarry Ranch.pdfRevision 3.pdf 1 DOC 3/31/2020 EtrakitPublicReg 1ST SUBMITTAL FIRE FLOW ANALYSIS Doc - Mar 25 2020 - 2-47 PM.pdf 1 DOC 3/31/2020 EtrakitPublicReg 1ST SUBMITTAL GLOBE CONCEALED Globe GL4906 4.9K.pdf 1 DOC 3/31/2020 EtrakitPublicReg 1ST SUBMITTAL GLOBE RECESSED Globe Recessed Pendent GL4110.pdf 1 DOC 3/31/2020 EtrakitPublicReg 1ST SUBMITTAL HYDRAULIC CALCS Quarry Ranch Calcs.pdf 1 DOC 12/2/2020 KAYLI ALFORD extension request.pdf extension request.pdf 0 BOND INFORMATION REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) AARON HICKSON 3/31/2020 4/1/2020 4/20/2020 COMPLETE 1ST FIRE (2 WK)KOHL HETRICK 3/31/2020 4/14/2020 4/15/2020 APPROVED SEE ATTACHMENTS 1ST FIRE (2 WK)KOHL HETRICK 4/27/2020 5/11/2020 4/29/2020 REVISIONS REQUIRED REVISION 1 - WM CHANGE SEE ATTACHMENTS. 1ST FIRE (1 DAY)KOHL HETRICK 4/30/2020 5/4/2020 5/4/2020 APPROVED Rev 2 - WM Change SEE IN ATTACHMENTS Printed: Friday, February 17, 2023 9:48:58 AM 4 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0054 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/15/2020 KOHL HETRICK FSS2020-0054 - 1ST SUBMITTAL PLANS - APPROVED.pdf FSS2020-0054 - 1ST SUBMITTAL PLANS - APPROVED.pdf 1 DOC 4/15/2020 KOHL HETRICK FSS2020-0054 - COA AND JOB CARD.pdf FSS2020-0054 - COA AND JOB CARD.pdf 1 DOC 4/29/2020 KOHL HETRICK FSS2020-0054 - REVISION 1 PLANS and CALCS - CORRECTIONS.pdf FSS2020-0054 - REVISION 1 PLANS and CALCS - CORRECTIONS.pdf 1 DOC 4/29/2020 KOHL HETRICK 4-28-2020 - OH Rough Inspection - Corrections Notice.pdf 4-28-2020 - OH Rough Inspection - Corrections Notice.pdf 1 DOC 5/4/2020 KOHL HETRICK FSS2020-0054 - REVISION 2 PLANS and CALCS - APPROVED.pdf FSS2020-0054 - REVISION 2 PLANS and CALCS - APPROVED.pdf 1 Printed: Friday, February 17, 2023 9:48:58 AM 5 of 5 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0054 FSS2020-0054 - REVISION 2 3'-61_2"14' - 6 1/2"1" Fire Riser Master Bedroom Master Bath Office Covered Patio Kitchen Great Room Dining Bed 2 Bed 3 Bed 4 Laundry Ba 2 Powr Portico Entry Courtyard Car Garage 1 Car Garage 2 WIC WIC WIC 1 1/2"53' -0"1 1/2" 26' -0"1"10' -1"1"13' -5"1"16' -1 1/2"1"13' -5"1"16' -1 1/2"1"10' -1 1/2"1"12' -0 1/2"1"2' -4 1/2"1" 14' -6" 1" 3' -7"1"14' -7 1/2"1" 3' -11" 1" 2' -1"1"8' -0"1"1' -9"1"0' -5"1" 9' -2"1"3' -6"1"3' -6"1"9' -6 1/2"1"9' -6 1/2"1" 11' -6" 1" 4' -10 1/2"1" 3' -4"1"10' -1 1/2"1"13' -3 1/2"1"9' -5 1/2"1"4' -10 1/2"1"6' -0 1/2"1"2' -6"1" 8' -6" 1" 9' -8 1/2"1"0' -10"1" 4' -0 1/2"1"4' -1 1/2"1"1' -4 1/2"1" 1' -8"1"4' -1 1/2"1"4' -1 1/2"1"6' -4 1/2"1"9' -2"1"6' -6 1/2"1" 7' -10" 1" 0' -4 1/2" 1" 2' -4 1/2"1"6' -6"1" 3' -11 1/2" 1" 0' -6 1/2" 1" 0' -4" 1" 3' -3" 1" 6' -10" 1" 6' -10" 1" 10' -0"1"8' -10"1" 0' -11 1/2" 1" 0' -10" 1" 7' -9" 1" 2' -8" 1" 3' -9" 1" 0' -6 1/2"1"10' -9"1"10' -9"1"5' -8"1" 4' -0" 1" 0' -9" 1" 5' -6" 1" 2' -0 1/2" 1" 1' -10 1/2" 1" 1' -3 1/2" 1" 11' -10 1/2" 1" 1' -1 1/2"1"3' -6 1/2"1"3' -6 1/2"1" 4' -2 1/2"1"10' -1"1"3' -3 1/2"1" 11' -4" Calc Area -1 3/4" Water Meter 1-1/2" PVC UG By OthersSupply Point Water Supply Information Static Pressure: Residual Pressure: Residual Flow: Additional Hose Flow: 75.47 psi 67.23 psi 1750 GPM 0 GPM Remote area number: Occupancy classification: Density: Area of application: Total water required (including hose streams): @ a required system pressure of: Fire Protection System Demand: No. of sprinklers calculated: Inside Hose Streams: Outside Hose Streams: Calc-1 R-3 2 Gpm/SqFt 512 Max SqFt 31.1103 GPM 43.714 Psi 5 GPM 0 GPM 6 1 5 BOR TOR 7 2 WM DOM 4 WATER NOTE: 3/4" Water Meter will Create an additional 15 psi max loss at the meter leaving 8.516 psi safety margin which is = to a 19% safety margin CEILING HIGHT 10 CEILING HIGHT 15' CEILING HIGHT 12' 12' - 6"1" x 2' -6"1" x 2' -6"1" x 2' -6"1" x 2' -6"3 1) System needs to be charged to static pressure for hydro 2) Fuel -fired utiliy in garage ( Head Added) 3) Bath 3 ( Head Added) 4) Office ( Head Added) 5) CPVC Pipe protection ( Pipe insulation added to avoid insulation contact) NOTE: Calulations reflect a 15 psi loss due to 3/4" water meter Correction Notes info@worldfireprotection.com Scale Project number Date Drawn by Checked by World Fire Protection41905 Boardwalk Suite BPalm Desert, Ca. 92211760-565-6030C-16 # 10497203/16" = 1'-0"4/29/2020 2:19:59 PMFP-1 Sprinkler Plan Project Number 03-26-2020 JA LS No. Description Date 1 Revision 1 Date 1 GIGI CRONIN RESIDENCE58585 Quarry Ranch RoadLa Quinta, Ca. 92253THE QUARRY LOT 63/16" = 1'-0"1 Sprinkler Plan Sprinkler Schedule K-Factor Manufacturer Description Temperature Rating Count 4.9 GLOBE Globe GL4906Pendent Light Hazard Quick Response1/2 Orifice 3mm GB 155 °F 39 4.9 GLOBE Globe GL4910 Recesed Pendent Light Hazard Quick Response1/2 Orifice 3mm GB 200 °F 10 World Fire Protection 41905 Boardwalk Suite B Your Street Address 2 Palm Desert, Ca. 92211 760-565-6030 Job Name : Quarry Ranch Drawing : Location : Remote Area : Contract : Data File : Quarry Ranch Area Calc-1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.2 World Fire ProtectionPage 1 Quarry RanchDate 10203040E50R60U70S80S90E100R110P120130140150200 400 600 800 1000 1200 1400 1600 1800FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 75.47 C2 - Residual Pressure: 67.23 C2 - Residual Flow : 1750 D1 - Elevation : 5.630 D2 - System Flow : 31.185 D2 - System Pressure : 60.255 Hose ( Demand ) : _______D3 - System Demand : 31.185 Safety Margin : 15.210 D1D2Water Supply Curve CComputer Programs by Hydratec Inc. Revision: 50.54.2 World Fire ProtectionPage 2 Quarry RanchDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 6071 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.54.2 World Fire Protection Page 3 Quarry Ranch Date Node Elevation K-Fact Pt Pn Flow Density Area Press No.Actual Actual Req. 1 10.0 4.9 7.04 na 13.0 0.05 60 7.04 2 10.5 7.62 na 3 10.5 13.5 na 4 13.0 14.91 na TOR 10.5 31.59 na DOM 4.42 35.34 na BOR 1.0 37.2 na 5.0 5 -3.0 41.41 na 8 -3.0 43.77 na WM -3.0 43.85 na 9 -3.0 60.26 na 6 10.0 4.9 7.24 na 13.18 0.05 46 7.0 7 13.0 14.37 na The maximum velocity is 10.51 and it occurs in the pipe between nodes BOR and 5 Pressure / Flow Summary - STANDARD Computer Programs by Hydratec Inc. Revision: 50.54.2 World Fire Protection Page 4 Quarry Ranch Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 10 4.90 13.00 1 2N 14.0 11.980 150 7.040 to 0.0 14.000 -0.217 2 10.5 13.0 1.101 0.0 25.980 0.0307 0.797 Vel = 4.38 2 10.5 13.18 1 2O 10.0 36.520 150 7.620 to 6R 6.0 16.000 0.0 3 10.5 26.18 1.101 0.0 52.520 0.1120 5.883 Vel = 8.82 3 10.5 -11.78 1 2N 14.0 42.120 150 13.503 to 2O 10.0 25.000 -1.083 4 13 14.4 1.101 R 1.0 67.120 0.0371 2.489 Vel = 4.85 4 13 11.78 1 5E 19.125 91.480 150 14.909 to 3T 28.688 47.814 1.083 TOR 10.5 26.18 1.101 0.0 139.294 0.1120 15.602 Vel = 8.82 TOR 10.5 0.0 1 E 3.825 6.080 150 31.594 to 0.0 3.825 2.633 DOM 4.42 26.18 1.101 0.0 9.905 0.1120 1.109 Vel = 8.82 DOM 4.42 0.0 1 0.0 3.420 150 35.336 to 0.0 0.0 1.481 BOR 1 26.18 1.101 0.0 3.420 0.1123 0.384 Vel = 8.82 BOR 1 + 5.00 5.00 1 3E 11.475 4.500 150 37.201 to 0.0 11.475 1.732 5 -3 31.18 1.101 0.0 15.975 0.1547 2.472 Vel = 10.51 5 -3 0.0 1.5 2E 11.656 82.030 150 41.405 to 0.0 11.656 0.0 8 -3 31.18 1.598 0.0 93.686 0.0252 2.363 Vel = 4.99 8 -3 0.0 1 0.0 0.500 150 43.768 to 0.0 0.0 0.0 WM -3 31.18 1.101 0.0 0.500 0.1560 0.078 Vel = 10.51 WM -3 0.0 1 0.0 9.110 150 43.846 to 0.0 0.0 15.000 * * Fixed Loss = 15 9 -3 31.18 1.101 0.0 9.110 0.1547 1.409 Vel = 10.51 0.0 9 31.18 60.255 K Factor = 4.02 6 10 4.90 13.18 1 2N 14.0 4.000 150 7.239 to R 1.0 15.000 -0.217 2 10.5 13.18 1.101 0.0 19.000 0.0315 0.598 Vel = 4.44 0.0 2 13.18 7.620 K Factor = 4.77 3 10.5 11.78 1 4R 4.0 53.470 150 13.503 to O 5.0 23.000 -1.083 7 13 11.78 1.101 2N 14.0 76.470 0.0256 1.954 Vel = 3.97 7 13 0.0 1 T 9.563 11.350 150 14.374 to 0.0 9.562 0.0 4 13 11.78 1.101 0.0 20.912 0.0256 0.535 Vel = 3.97 0.0 4 11.78 14.909 K Factor = 3.05 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.54.2 Permit Extension Request Letter To Whom it May Concer, This letter is to request an extension for our fire sprinkler permit number: FSS2020-0054 58585. The owner of the property has had some issues which caused the progress of his project to move along at a less than desirable pace. Due to the delay of the over-all project is has caused us to be unable to finish our trim work until just a couple days ago. Please let me know if you require any other information. Thank you -Blake Chapman President World Fire Protection, Inc. OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org April 15, 2020 World Fire Protection 41905 Boardwalk #B Palm Desert, CA 92211 Re: Residential Fire Sprinkler Plan Review – ABSOLUTE PARTNERS FSS2020-0054 / 58585 QUARRY RANCH RD, LA QUINTA, CA 92253 The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 58585 QUARRY RANCH ROAD PERMIT#: FSS2020-0054 DATE ISSUED: 4/15/2020 DESCRIPTION: RES. FIRE SPRINKLER SYSTEM CONTRACTOR: WORLD FIRE PROTECTION HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible dur ing the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY.