Loading...
FSS2020-0059ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (949)789-1600 jamieb@fireinc.net BILL TO FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (949)789-1600 jamieb@fireinc.net CONTRACTOR FIRE SPRINKLER SYSTEMS INC 705 E HARRISON ST STE 200 CORONA CA 92879 (949)789-1600 jamieb@fireinc.net OWNER LENNAR HOMES OF CALIFORNIA INC 15131 ALTON PKWY #345 IRVINE CA 92618 (949)789-1600 carey.adams@lennar.c om CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE KAYLI ALFORD 7/17/2020 7/17/2020 MSATER PLAN FCMP2020-0001 -PLAN TYPE 5 CONDITIONS Description: GRIFFIN RANCH / BRES2019-0481 / FIRE SPRINKLER / PLAN 5B Type: FIRE SPRINKLER Subtype: RESIDENTIAL - TRACT HOMES Status: FINALED Applied: 4/27/2020 AMA Parcel No: 767770046 Site Address: 81272 MERV GRIFFIN WY LA QUINTA,CA 92253 Approved: 4/27/2020 AMA Subdivision: TR 32879 Block: Lot: 39 Issued: 4/27/2020 Online Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 7/22/2020 KHET Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Wednesday, February 08, 2023 3:11:47 PM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0059 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES OVERHEAD ROUGH PIPING KHET 4/29/2020 4/29/2020 APPROVED SEE NOTES REMOTE VIDEO INSPECTION WM TO BOR EXCEEDS 70' (APPROX 120') BUCKET TEST REQUIRED AS PART OF FINAL INSPECTION (FIELD). OVERHEAD HYRO KHET 4/29/2020 4/29/2020 APPROVED SEE NOTES REMOTE VIDEO INSPECTION WM TO BOR EXCEEDS 70' (APPROX 120') BUCKET TEST REQUIRED AS PART OF FINAL INSPECTION (FIELD). FIRE FINAL**KHET 7/22/2020 7/22/2020 APPROVED BUCKET TEST REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES PARENT PROJECTS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 $161.00 4/27/20 WEB4976 CREDIT FIRE SPRINKLER SYSTEMS INC ECON Total Paid for FIRE FEES: $161.00 $161.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 4/27/20 WEB4976 CREDIT FIRE SPRINKLER SYSTEMS INC ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 4/27/20 WEB4976 CREDIT FIRE SPRINKLER SYSTEMS INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$176.00 $176.00 Printed: Wednesday, February 08, 2023 3:11:47 PM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0059 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/4/2020 ARMANDO MAGALLON APPLICATION 3005_001.pdf 0 DOC 4/28/2020 KAYLI ALFORD 31630-DE Master Plan 4154 (AsBuilt3).pdf 31630-DE Master Plan 4154 (AsBuilt3).pdf 0 DOC 7/22/2020 KOHL HETRICK FSS2020-0059 Bucket Test Results.pdf FSS2020-0059 Bucket Test Results.pdf 1 BOND INFORMATION 1ST FIRE (2 WK)FIRE BUCKET 1ST PERMIT TECH (1 DAY) ARMANDO MAGALLON 4/27/2020 4/28/2020 4/28/2020 COMPLETE PERMITS WERE PREVIOUSLY APPROVED BY MASTER PLAN PLAN CHECK FEE HAS BEEN REMOVED Printed: Wednesday, February 08, 2023 3:11:47 PM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER FSS2020-0059 Bucket Test Procedure – by FSS Kohl Hetrick Contractor to provide (2) 30G+ bins pre-marked at preferably 1gal intervals, though every 5gal marks are acceptable. Bins are placed at each of the design area fire sprinklers. These head locations are provided with an adapter extending down from the ceiling level and provided with a 1/4 turn .5-inch ball valve. The piping for this adapter shall not be greater than the pipe serving that particular head (i.e. 3/4”). An additional 5gal bucket is provided for measuring domestic demand at spigot nearest fire riser. Inspector will be at riser and domestic spigot with contractor, stopwatch ready. Helper(s) will be at the 2 design heads. Through communication on phone or radio, signal “All Start.” Everyone turns on their valves and stopwatch is started. Once the 5gal bucket at Dom spigot is at reasonable max fill, signal “All Stop”. Everyone closes valves and stopwatch is stopped. Inspect the volumes acquired in the 2 bins at the sprinkler heads. Starting with the one with the least volume, take the amount in gallons and divide by the number of seconds observed on the stopwatch. This will give you the gallons per second. Now multiply that number by 60 to establish the gallons per minute for that single head. Q = (V/T)60 Where: Q is the flow in gallons per minute (gpm) at a single head discharge point. V is the volume in gallons (approximate) observed discharged from the single head discharge point T is the time in seconds (including fraction) it took to fill the 5-gallon container at the domestic spigot valve. *This may be less than or greater than 60 seconds. Example: 6 gallons observed at one of the design head discharges in 25 seconds 6/25= .24 gallons per second .24x60= 14.4 gallons per minute For the common K4.9 factor head doing a maximum 16x16 spacing, a minimum 13gpm needs to be provided to the most remote/demanding head(s). This bucket test flow was satisfactory. Both heads flowed the minimum gpm and you confirmed the minimum 5gpm domestic demand. PERMIT: _____________________ Address: ________________________________________________ Static Pressure: _____________ *after blead-off **For documentation only. Residual Pressure: _____________ *while flowing design heads and domestic simultaneously **For documentation only. Time (T): ___________ seconds Volume 1(V1): ____________ gallons Volume 2(V2): ____________ gallons Head 1 = (Q) __________ = ((V1) _______ / (T) ________) x 60 Pass ☐ Fail ☐ [Required flow: _______ gpm] Head 2 = (Q) __________ = ((V2) _______ / (T) ________) x 60 Pass ☐ Fail ☐ [Required flow: _______ gpm] *Head 3 = (Q) __________ = ((V3) _______ / (T) ________) x 60 Pass ☐ Fail ☐ [Required flow: _______ gpm] *Optional – for 3-head calculation situations. Will require a 3rd 30-Gallon bucket. FSS2020-0059 81272 Merv Griffin 25 20 5.5 5.5 16.5 16.5 5.5 20 5.5 20 13 13 85 x x